Oskan Yalcın S, Kaplan AT. Comparison of intraocular pressure measurements with the tono-pen, goldmann applanation tonometer, and noncontact tonometer in nonglaucomatous pseudophakic children. Int Ophthalmol 2024; 44:285. [PMID: 38935310 DOI: 10.1007/s10792-024-03210-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2024] [Accepted: 06/15/2024] [Indexed: 06/28/2024]
Abstract
BACKGROUND To evaluate the agreement between the Goldman applanation tonometer (GAT), Tono-Pen, and noncontact tonometer (NCT) in the measurement of intraocular pressure (IOP) in pseudophakic children. METHODS The medical records of nonglaucomatous pseudophakic children between 2009 and 2019 were retrospectively analyzed. A total of 46 eyes of 23 patients operated for bilateral pediatric cataract were included in the study. The patients' mean age was 13.4 ± 4.1 years. Central corneal thickness (CCT) and IOP values measured with the GAT, Tono-Pen, and NCT were recorded. Agreement between the tonometers was evaluated by intraclass correlation coefficients (ICC) and the Bland-Altman method. RESULTS The mean IOP of the 46 eyes included in the study was measured as 13.7 ± 2.3 mm Hg with the GAT, 16.0 ± 2.3 mm Hg with NCT, and 16.5 ± 2.3 mm Hg with the Tono-Pen (p < 0.001). There is no statistical difference between NCT and Tono-Pen measurements, while GAT measurements were significantly lower than those of the NCT and Tono-pen. ICC values showed fair agreement between NCT and Tono-Pen (ICC = 0.720), whereas there was poor agreement between GAT and NCT (ICC = 0.501) and Tono-pen (ICC = 0.314). CONCLUSIONS With all devices included in the study, thicker corneas were associated with higher IOP measurements. Although there was moderate agreement between the NCT and Tono-Pen, there was a statistically significant difference in the IOP values provided by the three devices. Our results suggest these devices should not be used interchangeably.
Collapse
Affiliation(s)
- Sibel Oskan Yalcın
- Department of Opthalmology, Kartal Dr. Lütfi Kırdar City Hospital, Kartal, Istanbul, Turkey.
| | - Aysin Tuba Kaplan
- Department of Opthalmology, Kartal Dr. Lütfi Kırdar City Hospital, Kartal, Istanbul, Turkey
| |
Collapse
|
2
|
Yang Z, Miao N, Wang L, Ma K. Comparison of different correction formulas and measurement methods for the accurate determination of intraocular pressure after SMILE and FS-LASIK surgery. BMC Ophthalmol 2022; 22:404. [PMID: 36217120 PMCID: PMC9549448 DOI: 10.1186/s12886-022-02620-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2022] [Accepted: 09/26/2022] [Indexed: 11/23/2022] Open
Abstract
Background To compare the accuracy of non-contact tonometry, Pentacam, and corneal visualization Scheimpflug technology (Corvis ST) for the measurement of intraocular pressure (IOP) after small incision lenticule extraction (SMILE) or femtosecond laser-assisted in situ keratomileusis (FS-LASIK) surgery. Methods A total of 49 patients (98 eyes) undergoing FS-LASIK or SMILE surgery at West China Hospital, Sichuan University from January to March 2021 were enrolled in this prospective, comparative, self-controlled study. IOP values were measured with non-contact tonometer, Pentacam, and Corvis ST before surgery and 1 month after surgery. Pentacam-derived postoperative IOP values were corrected using five correction formulas (Ehlers, Shah, Dresden, Orssengo-Pye, and Kohlhaas), while Corvis ST-derived values were corrected using a single formula. Results In the SMILE group, no significant differences were observed between the IOP values corrected with the Shah formula before and after surgery (t = 0.17, P = 0.869), whereas postoperative IOP values corrected with the other formulas were significantly different from the corresponding preoperative measurements (P < 0.05). In the FS-LASIK group, postoperative IOP values corrected with the Ehlers, Shah, or Corvis ST formulas were significantly different from the corresponding preoperative IOP measurements (P < 0.05), but no significant differences were observed between pre- and postoperative IOP values corrected with the Dresden (t = − 0.08, P = 0.941), Orssengo-Pye (t = − 0.52, P = 0.604), or Kohlhaas (t = 1.22, P = 0.231) formulas. Conclusions Pentacam’s Shah correction formula seemed to be the most appropriate method for accurately measuring postoperative IOP in patients undergoing SMILE surgery, while the Dresden, Orssengo-Pye, and Kohlhaas correction formulas of Pentacam were identified as the most reliable methods for estimating IOP in patients after FS-LASIK surgery. Supplementary Information The online version contains supplementary material available at 10.1186/s12886-022-02620-7.
Collapse
Affiliation(s)
- Zhiqing Yang
- Department of Ophthalmology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan Province, China.,West China Medical School, Sichuan University, Chengdu, 610041, Sichuan Province, China
| | - Na Miao
- Department of Ophthalmology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan Province, China
| | - Lixiang Wang
- Department of Ophthalmology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan Province, China
| | - Ke Ma
- Department of Ophthalmology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan Province, China.
| |
Collapse
|
3
|
Iglesias M, Kudsieh B, Laiseca A, Santos C, Nadal J, Barraquer R, Casaroli-Marano RP. Intraocular pressure after myopic laser refractive surgery measured with a new Goldmann convex prism: correlations with GAT and ORA. BMC Ophthalmol 2022; 22:79. [PMID: 35168601 PMCID: PMC8849021 DOI: 10.1186/s12886-022-02309-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2021] [Accepted: 02/09/2022] [Indexed: 12/04/2022] Open
Abstract
Background The purpose of this study is to describe measurements using a newly developed modified Goldmann convex tonometer (CT) 1 year after myopic laser refractive surgery. Intraocular pressure (IOP) measurements were compared with IOP values obtained by Goldmann applanation tonometer (GAT), and Ocular Response Analyzer (ORA). Methods Prospective double-masked study performed on thirty eyes of thirty patients that underwent laser in situ keratomileusis (LASIK; n = 19) or photorefractive keratectomy (PRK; n = 11). IOP was measured before and 3 and 12 months after surgery. Intraclass correlation coefficient (ICC) and Bland-Altman plot were calculated to assess the agreement between GAT, CT, IOPg (Goldmann-correlated IOP) and IOPcc (corneal-compensated IOP) from ORA. Results Twelve months after LASIK, IOP measured with CT showed the best correlation with IOP measured with GAT before surgery (GATpre) (ICC = 0.886, 95% CI: 0.703–0.956) (15.60 ± 3.27 vs 15.80 ± 3.22; p < 0.000). However, a moderate correlation was found for IOP measured with IOPcc and CT 12 months after LASIK (ICC = 0.568, 95% CI: − 0.185 – 0.843) (15.80 ± 3.22 vs 12.87 ± 2.77; p < 0.004). Twelve months after PRK, CT showed a weak correlation (ICC = − 0.266, 95% CI: − 3.896 – 0.663), compared to GATpre (17.30 ± 3.47 vs 16.01 ± 1.45; p < 0.642), as well as poor correlation (ICC = 0.256, 95% CI: − 0.332 – 0.719) with IOPcc (17.30 ± 3.47 vs 13.38 ± 1.65; p < 0.182). Conclusions Twelve months after LASIK, IOP measured with CT strongly correlated with GAT before surgery and could therefore provide an alternative method for measuring IOP after this surgery. More studies regarding this new convex prism are needed to assess its accuracy.
Collapse
Affiliation(s)
- María Iglesias
- Instituto Universitario Barraquer, Barraquer Ophthalmology Centre, Laforja 88, 08012, Barcelona, Spain.
| | - Bachar Kudsieh
- Department of Ophthalmology, Hospital Universitario Puerta De Hierro, 28222, Madrid, Spain
| | - Andrea Laiseca
- Instituto Universitario Barraquer, Barraquer Ophthalmology Centre, Laforja 88, 08012, Barcelona, Spain
| | - Cristina Santos
- Unitat Antropologia Biològica, Department Biologia Animal, Biologia Vegetal i Ecologia, Universitat Autònoma de Barcelona (UAB), 08193, Barcelona, Spain
| | - Jeroni Nadal
- Instituto Universitario Barraquer, Barraquer Ophthalmology Centre, Laforja 88, 08012, Barcelona, Spain
| | - Rafael Barraquer
- Instituto Universitario Barraquer, Barraquer Ophthalmology Centre, Laforja 88, 08012, Barcelona, Spain.,International University of Catalunya (UIC), 08017, Barcelona, Spain
| | - Ricardo P Casaroli-Marano
- Department of Surgery, School of Medicine and Hospital Clinic de Barcelona, University of Barcelona (UB), 08036, Barcelona, Spain
| |
Collapse
|
4
|
Yahalomi T, Kovalyuk N, Arnon R, Hen B, Pikkel J. The effect of central corneal thickness on Goldmann tonometry: a retrospective study. Int Ophthalmol 2021; 42:253-259. [PMID: 34554360 DOI: 10.1007/s10792-021-02021-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2021] [Accepted: 09/11/2021] [Indexed: 10/20/2022]
Abstract
PURPOSE To determine the relation between central corneal thickness and intraocular pressure. PATIENTS AND METHODS This retrospective study investigated 112 eyes from 56 individuals who underwent photorefractive keratectomy in a single private medical center between May 2018 and September 2019. Intraocular pressure readings were obtained with Goldmann applanation tonometry, and central corneal thickness measurements were evaluated preoperatively. All the examinations were repeated at 3 and 6 months postoperative. RESULTS At 3 and 6 months postoperative, the mean intraocular pressure was only slightly reduced from baseline (mean reduction of 0.6 ± 2.0 mmHg, P < 0.001 and 0.73 ± 2.14 mmHg, P < 0.001, respectively). The change in intraocular pressure following photorefractive keratectomy was not clinically significant, and this change was not correlated with postoperative central corneal thickness at 3 months (p = 0.620, r = 0.047). CONCLUSION This study showed that the change in intraocular pressure following photorefractive keratectomy was not clinically significant, and ruled out a correlation in this context between the change in central corneal thickness and the delta intraocular pressure. Our results might question the axiom between central corneal thickness and intraocular pressure and may thus challenge the current clinical setting for evaluating glaucoma.
Collapse
Affiliation(s)
- Tal Yahalomi
- Department of Ophthalmology, Faculty of Health Sciences, Samson Assuta Ashdod Hospital, Ben-Gurion University of the Negev, Beersheba, Israel.
| | - Natalya Kovalyuk
- Department of Ophthalmology, Faculty of Health Sciences, Samson Assuta Ashdod Hospital, Ben-Gurion University of the Negev, Beersheba, Israel
| | - Roee Arnon
- Department of Ophthalmology, Faculty of Health Sciences, Samson Assuta Ashdod Hospital, Ben-Gurion University of the Negev, Beersheba, Israel
| | - Barak Hen
- Department of Ophthalmology, Faculty of Health Sciences, Samson Assuta Ashdod Hospital, Ben-Gurion University of the Negev, Beersheba, Israel
| | - Joseph Pikkel
- Department of Ophthalmology, Faculty of Health Sciences, Samson Assuta Ashdod Hospital, Ben-Gurion University of the Negev, Beersheba, Israel
| |
Collapse
|
5
|
Zhang H, Sun Z, Li L, Sun R, Zhang H. Comparison of intraocular pressure measured by ocular response analyzer and Goldmann applanation tonometer after corneal refractive surgery: a systematic review and meta-analysis. BMC Ophthalmol 2020; 20:23. [PMID: 31924174 PMCID: PMC6954592 DOI: 10.1186/s12886-019-1288-6] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2019] [Accepted: 12/27/2019] [Indexed: 01/07/2023] Open
Abstract
BACKGROUND Accurate measurement of intraocular pressure (IOP) after corneal refractive surgery is of great significance to clinic, and comparisons among various IOP measuring instruments are not rare, but there is a lack of unified analysis. Although Goldmann Applanation Tonometer (GAT) is currently the internationally recognized gold standard for IOP measurement, its results are severely affected by central corneal thickness (CCT). Ocular Response Analyzer (ORA) takes certain biomechanical properties of cornea into account and is supposed to be less dependent of CCT. In this study, we conducted the meta-analysis to systematically assess the differences and similarities of IOP values measured by ORA and GAT in patients after corneal refractive surgery from the perspective of evidence-based medicine. METHODS The authors searched electronic databases (MEDLINE, EMBASE, Web of science, Cochrane library and Chinese electronic databases of CNKI and Wanfang) from Jan. 2005 to Jan. 2019, studies describing IOP comparisons measured by GAT and ORA after corneal refractive surgery were included. Quality assessment, subgroup analysis, meta-regression analysis and publication bias analysis were applied in succession. RESULTS Among the 273 literatures initially retrieved, 8 literatures (13 groups of data) with a total of 724 eyes were included in the meta-analysis, and all of which were English literatures. In the pooled analysis, the weighted mean difference (WMD) between IOPcc and IOPGAT was 2.67 mmHg (95% CI: 2.20~3.14 mmHg, p < 0.0001), the WMD between IOPg and IOPGAT was - 0.27 mmHg (95% CI: - 0.70~0.16 mmHg, p = 0.2174). In the subgroup analysis of postoperative IOPcc and IOPGAT, the heterogeneity among the data on surgical procedure was zero, while the heterogeneity of other subgroups was still more than 50%. The comparison of the mean difference of pre- and post-operative IOP (∆IOP) was: mean-∆IOPg > mean-∆IOPGAT > mean-∆IOPcc. CONCLUSIONS IOPcc, which is less dependent on CCT, may be more close to the true IOP after corneal refractive surgery compared with IOPg and IOPGAT, and the recovery of IOPcc after corneal surface refractive surgery may be more stable than that after lamellar refractive surgery.
Collapse
Affiliation(s)
- Hui Zhang
- School of Biomedical Engineering, Capital Medical University, Beijing, 100069, China.,Beijing Key Laboratory of Fundamental Research on Biomechanics in Clinical Application, Capital Medical University, Beijing, 100069, China
| | - Zhengtao Sun
- School of Biomedical Engineering, Capital Medical University, Beijing, 100069, China
| | - Lin Li
- School of Biomedical Engineering, Capital Medical University, Beijing, 100069, China.,Beijing Key Laboratory of Fundamental Research on Biomechanics in Clinical Application, Capital Medical University, Beijing, 100069, China
| | - Ran Sun
- Department of Ophthalmology, Xuanwu Hospital, Capital Medical University, Beijing, 100053, China
| | - Haixia Zhang
- School of Biomedical Engineering, Capital Medical University, Beijing, 100069, China. .,Beijing Key Laboratory of Fundamental Research on Biomechanics in Clinical Application, Capital Medical University, Beijing, 100069, China. .,School of Engineering, University of Liverpool, Liverpool, UK.
| |
Collapse
|
6
|
Bao F, Huang W, Zhu R, Lu N, Wang Y, Li H, Wu S, Lin H, Wang J, Zheng X, Huang J, Li Y, Wang Q, Elsheikh A. Effectiveness of the Goldmann Applanation Tonometer, the Dynamic Contour Tonometer, the Ocular Response Analyzer and the Corvis ST in Measuring Intraocular Pressure following FS-LASIK. Curr Eye Res 2019; 45:144-152. [PMID: 31869261 DOI: 10.1080/02713683.2019.1660794] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
Purpose: To test the performance of the four tonometers in providing IOP measurements that were free of the effects of corneal biomechanics changes caused by refractive surgery.Methods: Four tonometers were employed to provide IOP measurements for 65 participants who accepted Femtosecond laser-assisted LASIK (FS-LASIK). The measurements included GAT-IOP by the Goldmann Applanation Tonometer, DCT-IOP by the Dynamic Contour Tonometer, Goldmann-correlated IOP (ORA-IOPg) and corneal-compensated IOP (ORA-IOPcc) by the Ocular Response Analyzer, and uncorrected IOP (CVS-IOP) and biomechanically corrected IOP (CVS-bIOP) by the Corvis ST. Statistical analyses were performed to assess the association of the differences in IOP caused by FS-LASIK with central corneal thickness (CCT), mean corneal curvature (Km), age, refractive error correction (REC), optical zone diameter (OZD), ablation zone diameter (AZD), residual stromal bed thickness (RSB) and RSB ratio (RSB/CCT). Multiple linear regression models were constructed to explore factors influencing IOP changes.Results: All four tonometers exhibited significant differences between IOP measurements taken pre and post-surgery except for CVS-bIOP in the low to moderate myopia group (t = 1.602, p = .12). CVS-bIOP, followed by DCT-IOP, provided the best agreement between pre and post-FS-LASIK measurements with the lowest differences in IOP and the narrowest limits of agreement. The pre-post IOP differences were also significantly associated with the reduction in CCT in only GAT-IOP, ORA-IOPg, and CVS-IOP. CVS-bIOP and ORA-IOPcc were the only measurements that were not correlated with CCT, Km or age both before and after FS-LASIK.Conclusions: The biomechanically corrected bIOP from the Corvis ST provided post-FS-LASIK measurements that were in closest agreement with those obtained before surgery. In comparison, GAT-IOP, ORA-IOPg, ORA-IOPcc, and CVS-IOP appeared to be more influenced by the changes in corneal biomechanics caused by FS-LASIK.
Collapse
Affiliation(s)
- Fangjun Bao
- Eye Hospital, WenZhou Medical University, Wenzhou, China.,The Institution of Ocular Biomechanics, Wenzhou Medical University, Wenzhou, China
| | - Wei Huang
- Eye Hospital, WenZhou Medical University, Wenzhou, China
| | - Rong Zhu
- Eye Hospital, WenZhou Medical University, Wenzhou, China
| | - Nanji Lu
- Eye Hospital, WenZhou Medical University, Wenzhou, China
| | - Yuan Wang
- Eye Hospital, WenZhou Medical University, Wenzhou, China
| | - Hechen Li
- Eye Hospital, WenZhou Medical University, Wenzhou, China
| | - Songan Wu
- Eye Hospital, WenZhou Medical University, Wenzhou, China
| | - Huini Lin
- Eye Hospital, WenZhou Medical University, Wenzhou, China
| | - Junjie Wang
- Eye Hospital, WenZhou Medical University, Wenzhou, China.,The Institution of Ocular Biomechanics, Wenzhou Medical University, Wenzhou, China
| | - Xiaobo Zheng
- Eye Hospital, WenZhou Medical University, Wenzhou, China.,The Institution of Ocular Biomechanics, Wenzhou Medical University, Wenzhou, China
| | - JinHai Huang
- Eye Hospital, WenZhou Medical University, Wenzhou, China
| | - Yiyu Li
- Eye Hospital, WenZhou Medical University, Wenzhou, China
| | - Qinmei Wang
- Eye Hospital, WenZhou Medical University, Wenzhou, China.,The Institution of Ocular Biomechanics, Wenzhou Medical University, Wenzhou, China
| | - Ahmed Elsheikh
- School of Engineering, University of Liverpool, Liverpool, UK.,National Institute for Health Research (NIHR) Biomedical Research Centre for Ophthalmology, Moorfields Eye Hospital NHS Foundation Trust and UCL Institute of Ophthalmology, London, UK.,School of Biological Science and Biomedical Engineering, Beihang University, Beijing, China
| |
Collapse
|
7
|
Abstract
Introduction: Laser in situ keratomileusis (LASIK), a refractive surgery procedure is being performed in a large number among people with refractive errors. In all the people undergoing the procedure, there is a potential risk to misdiagnose the glaucoma disease due to changes in central corneal thickness (CCT). In subjects who have undergone laser refractive interventions, intraocular tension may be lower and underestimated, and this can lead to later detection of glaucoma. Aim: The objective of this study was to analyze the intraocular pressure (IOP) after LASIK in patients with myopia. Methods: Thirty-seven patients underwent LASIK intervention to treat myopia. In total, 74 eyes were treated. Before the intervention, all patients underwent complete ophthalmologic examination, including the measurement of central corneal thickness (CCT) and measurement of IOP with non-contact tonometer. The IOP was also measured on days 1, 3 and 30 after the surgery. The mean IOP was taken for statistical analysis. Results: Seventy-four eyes of 37 patients (mean age 31.6) underwent LASIK intervention to treat myopia. Mean CCT before the intervention was 551.9 ±31.9µm, while mean postoperative CCT was 469.8 ±45.3µm (p<0.0001). Mean preoperative IOP was 16.4mmHg while mean postoperative IOP was 11.0mmHg (p<0.0001). The average spherical equivalent was -5.9 diopters. Conclusions: The reduction of IOP after LASIK refractive surgery is significant. This reduction is about 1mmHg per 1 diopter. This should be taken into account in the future in these patients because, due to the underestimation of the IOP, the glaucoma disease may be overlooked.
Collapse
Affiliation(s)
- Valbon Ajazaj
- Clinic Gjermane e Syrit, Prishtina, Republic of Kosovo
| | | | - Minir Asani
- Clinic Gjermane e Syrit, Prishtina, Republic of Kosovo.,Domed Augenklinik Westfalen, Dortmund, Germany
| | - Afrim Shabani
- Clinic Gjermane e Syrit, Prishtina, Republic of Kosovo
| | - Ermal Dida
- Clinic Gjermane e Syrit, Prishtina, Republic of Kosovo
| |
Collapse
|
8
|
Effect of Hemifacial Spasm on Intraocular Pressure Measurement. J Ophthalmol 2018; 2018:3621215. [PMID: 29545951 PMCID: PMC5818941 DOI: 10.1155/2018/3621215] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2017] [Revised: 11/23/2017] [Accepted: 11/28/2017] [Indexed: 11/17/2022] Open
Abstract
Purpose To evaluate the effect of hemifacial spasm (HFS) on intraocular pressure (IOP) measurement. Methods Twenty-four consecutive patients with HFS and 25 age- and gender-matched randomly selected eyes of healthy volunteers underwent corneal pachymetry and IOP measurements using Goldmann applanation tonometer (GAT) and noncontact tonometer (NCT). IOP measurements were performed before (during HFS) and 2 weeks after Botox injections in HFS patients and in healthy volunteers without Botox injections. Results There was no statistical difference between involved eye side and uninvolved eye side of HFS patients in measured central corneal thickness. Similarly, no difference was found between involved eye side of HFS patients and controls. There were no statistically significant differences comparing IOP values before treatment and levels measured at 2 weeks of Botox injections, either with GAT (p = 0.33, 0.11) or NCT (p = 0.80, 0.43) devices in the involved eyes and uninvolved eyes of patients with HFS, respectively. There were also no significant differences in these parameters (GAT (p = 0.63) and NCT (p = 0.54)) in controls. Conclusions Contractions in facial muscles may not lead to significant increase in IOP in HFS patients. This result may help clinical decision making in the treatment of glaucoma patients with HFS. This trial is registered with NCT03390803.
Collapse
|
9
|
Hosny M, Aboalazayem F, El Shiwy H, Salem M. Comparison of different intraocular pressure measurement techniques in normal eyes and post small incision lenticule extraction. Clin Ophthalmol 2017; 11:1309-1314. [PMID: 28761329 PMCID: PMC5522824 DOI: 10.2147/opth.s132578] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Purpose The purpose of the study was to determine the accuracy of intraocular pressure (IOP) measurement after small incision lenticule extraction (SMILE) using Goldmann applanation tonometry (GAT) and ocular response analyzer (ORA). Methods This is a prospective clinical study that was conducted on 30 eyes in the interval between February 2016 and September 2016. The age of the patients ranged between 19 and 40 years. The patients underwent SMILE surgery using the femto laser. IOP was measured preoperatively and 1 month postoperatively by both techniques, the GAT and the ORA. Results GAT recorded lower values than ORA values (IOPcc) preoperatively and postoperatively and the difference was statistically significant. Both GAT and ORA IOP measurements decreased after SMILE. There was no statistically significant correlation between the changes in the GAT and ORA readings and the postoperative corneal pachymetry or the lenticule thickness. Both corneal hysteresis and corneal resistance factor showed significant decline after the procedure, which correlated with the lenticule thickness. Conclusion SMILE causes significant reduction in IOP measurement by ORA and GAT. Corneal biomechanics decreases following SMILE and this correlates with lenticule thickness.
Collapse
Affiliation(s)
- Mohamed Hosny
- Department of Ophthalmology, Cairo University, Giza, Egypt
| | | | - Hoda El Shiwy
- Department of Ophthalmology, Cairo University, Giza, Egypt
| | - Mohsen Salem
- Department of Ophthalmology, Cairo University, Giza, Egypt
| |
Collapse
|
10
|
Refai TA, Hassanin OA. Refinement of Intraocular Pressure Measurements made by Ocular Response Analyzer following Laser in Situ Keratomileusis using M2 90 Moria Microkeratome for Egyptian Myopic and Astigmatic Patients. Electron Physician 2017; 8:3429-3433. [PMID: 28163860 PMCID: PMC5279978 DOI: 10.19082/3429] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2016] [Accepted: 10/17/2016] [Indexed: 11/20/2022] Open
Abstract
INTRODUCTION The Goldmann applanation tonometer readings were noted to be markedly reduced after Lasik surgery using a thin flap technique which is widely used nowadays, to correct a wide range of myopia and astigmatism. The Ocular Response Analyzer (ORA) is considered one of the important tools for refinement of Intraocular Pressure (IOP) measurements. The aim of this study is to evaluate and refine ORA measurements for IOP changes post- M2 90 Moria microkeratome Lasik procedure for Egyptian myopic and astigmatic patients trying to aid in glaucoma diagnosis and management. METHODS Thirty-five eyes of nineteen Egyptian patients with myopia or myopic astigmatism who had undergone Lasik procedure using M2 90 Moria microkeratome were included in this consecutive case series study. All cases were subjected to full ophthalmological examination including uncorrected and best corrected visual acuity, refraction, slit lamp examination, Scheimpflug imaging and ORA (Reichert Ophthalmic Instruments, Inc., Buffalo, NY, USA). The refractive errors were measured using an auto refractometer and were confirmed by trial. For the ocular response analyzer, the Goldmann-correlated IOP measurement (IOPg) which simulates IOP measured by Goldmann tonometer and the Corneal-Compensated Intraocular Pressure (IOPcc) that takes corneal biomechanical properties into consideration were reported as well as the Corneal Hysteresis (CH) and the Corneal Resistance Factor (CRF). Cases were examined preoperatively and again about one month after Lasik, after stabilization of eye condition. The collected data were tabulated and analysed with the suitable statistical methods. The mean values and standard deviation were calculated for quantitative data. Comparison tests (t-test) and correlation tests (Pearson) were also performed. RESULTS In our study, involving M2 90 Moria microkeratome Lasik procedure, a highly significant post-Lasik reduction in IOPg (t-test = 8.62 (p<0.01), and a statistically significant reduction in IOPcc (t-test = 3.37 (p<0.05) by ocular response analyzer. The average post-Lasik reduction in IOP in mmHg was 4.84±2.82 for IOPg and 2.23±3.51for IOPcc. A statistically significant correlation (p<0.05) existed between post-Lasik reduction of IOPg and ablation depth as well as preoperative spherical equivalent. A non-significant correlation existed between post-Lasik reduction of IOPcc and both of ablation depth and preoperative spherical equivalent. CONCLUSIONS Following Lasik procedure using M2 90 Moria microkeratome, the IOPcc values by ORA were closer to the preoperative values than the IOPg values and the reduction of IOPcc values was not affected by ablation depth (i.e. preoperative spherical equivalent). Therefore, it is advisable to use the IOPcc values by ORA when evaluating post-Lasik patients for glaucoma diagnosis and management, but with the addition of the average value for post-Lasik reduction which in the study was 2.23±3.51mmHg.
Collapse
Affiliation(s)
- Tamer Adel Refai
- Refractive Unit, Ophthalmology Department, Research Institute of Ophthalmology, Giza, Egypt
| | - Olfat A Hassanin
- Refractive Unit, Ophthalmology Department, Research Institute of Ophthalmology, Giza, Egypt
| |
Collapse
|
11
|
Eraslan M, Çerman E, Sümmen S. Comparison of Intraocular Pressure Measurements in Healthy Pediatric Patients using Three Types of Tonometers. Turk J Ophthalmol 2017; 47:1-4. [PMID: 28182167 PMCID: PMC5282535 DOI: 10.4274/tjo.92593] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2015] [Accepted: 04/22/2016] [Indexed: 12/05/2022] Open
Abstract
Objectives: This study aimed to compare intraocular pressure (IOP) measurements in healthy pediatric patients using three types of tonometers. Materials and Methods: Seventy-eight eyes of 78 patients under the age of 18 who underwent a routine ophthalmologic examination were included in the study. IOP was measured using Tono-Pen (TP) tonometry, Goldmann applanation tonometry (GAT), and non-contact tonometry (NCT), consecutively. IOP was adjusted based on central corneal thickness (CCT). Patients with any ocular disorders other than a limited refractive error were excluded from the study. Results: The study consisted of 46 girls and 32 boys. The mean age was 12.6±2.7 (range: 5-17) years. The mean CCT was 559.3±35.3 µm. The mean refractive error was -0.50±1.70. The mean level of visual acuity was 0.98±0.1 (range: 0.3-1.0) using the Snellen chart. Significant differences were found between the measurement results of each of the three tonometric methods. Mean IOP was 12.1±2.2 mmHg for TP, 15.7±2.5 mmHg for GAT, and 17.1±3.1 mmHg for NCT. The correlations between measurement methods revealed that the highest correlation was between NCT and GAT (p<0.001, r=0.670). The second highest correlation was between NCT and TP (p<0.001, r=0.477). The lowest correlation was between GAT and TP (p<0.001, r=0.403). A positive correlation was found between CCT and each IOP measurement method. Conclusion: In pediatric patients, TP and NCT measurements were found to be positively correlated with GAT measurements. Because TP measurements were lower than GAT measurements and NCT measurements were higher than GAT measurements, patient follow-ups, treatment strategies, and surgery plans must be organized taking these differences into consideration.
Collapse
Affiliation(s)
- Muhsin Eraslan
- Marmara University Faculty of Medicine, Department of Ophthalmology, İstanbul, Turkey
| | - Eren Çerman
- Marmara University Faculty of Medicine, Department of Ophthalmology, İstanbul, Turkey
| | - Sena Sümmen
- Marmara University Faculty of Medicine, Department of Ophthalmology, İstanbul, Turkey
| |
Collapse
|
12
|
Comparison of Intraocular Pressure before and after Laser In Situ Keratomileusis Refractive Surgery Measured with Perkins Tonometry, Noncontact Tonometry, and Transpalpebral Tonometry. J Ophthalmol 2015; 2015:683895. [PMID: 26167293 PMCID: PMC4475733 DOI: 10.1155/2015/683895] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2015] [Revised: 05/28/2015] [Accepted: 05/28/2015] [Indexed: 01/22/2023] Open
Abstract
Purpose. To compare the intraocular pressure (IOP) before and after Laser In Situ Keratomileusis (LASIK), measured by Diaton, Perkins, and noncontact air pulse tonometers. Methods. Fifty-seven patients with a mean age of 34.88 were scheduled for myopia LASIK treatment. Spherical equivalent refraction (SER), corneal curvature (K), and central corneal thickness (CCT) and superior corneal thickness (SCT) were obtained before and after LASIK surgery. IOP values before and after surgery were measured using Diaton, Perkins, and noncontact air pulse tonometers. Results. The IOP values before and after LASIK surgery using Perkins tonometer and air tonometers were statistically significant (p < 0.05). However, no significant differences were found (p > 0.05) for IOP values measured with Diaton tonometer. CCT decreases significantly after surgery (p < 0.05) but no statistical differences were found in SCT (p = 0.08). Correlations between pre- and postsurgery were found for all tonometers used, with p = 0.001 and r = 0.434 for the air pulse tonometer, p = 0.008 and r = 0.355 for Perkins, and p < 0.001 and r = 0.637 for Diaton. Conclusion. Transpalpebral tonometry may be useful for measuring postsurgery IOP after myopic LASIK ablation because this technique is not influenced by the treatment.
Collapse
|