1
|
Dan TT, Liu TX, Li ZZ, Liang CP, Li FY. The comparison of white-to-white via triple person-times caliper measuring and machine-measuring in V4c implantable collamer lens implantation. Sci Rep 2024; 14:13878. [PMID: 38880805 PMCID: PMC11180651 DOI: 10.1038/s41598-024-64647-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2024] [Accepted: 06/11/2024] [Indexed: 06/18/2024] Open
Abstract
This study aimed to compare the differences and characteristics of white-to-white (WTW) values obtained before V4c implantation using triple person-times caliper, IOL-Master 700, Pentacam HR, and UBM, and to assess their correlation with vaulting. A total of 930 myopia patients (1842 eyes) who were interested in undergoing ICL surgery were assessed before the procedure using various instruments. The WTW measurements were obtained using a triple person-times caliper, Pentacam HR, and IOL-Master 700, whereas the angle-to-angle (ATA) measurements were obtained using UBM. The size of the ICL was subsequently calculated using triple person-times caliper measurements. The vault of the ICL was assessed using Pentacam HR three months after the surgery. The WTW was determined to be 11.30 ± 0.29 mm, 11.43 ± 0.29 mm, and11.86 ± 0.38 mm, respectively, using the triple person-times caliper, Pentacam HR, and IOL-Master 700. The measurement of ATA was 11.57 ± 0.51 mm, as done by UBM. The ICL vault was measured to be 400.97 ± 198.46 µm when examined with Pentacam HR three monthsafter the procedure. The linear regression analyses of ICL size and WTW of triple person-times caliper, ICL vault and WTW were (R = 0.703, p < 0.001; R = 0.0969, p < 0.001) respectively. The highest correlation was found between IOL-Master and Pentacam HR (r = 0.766, p = 0.000). The lowest correlation was found between UBM and Pentacam HR (r = 0.358, p = 0.002). Bland-Altman analysis showed that the 95% limits of agreement (LoA) were the triple person-times caliper and Pentacam HR (- 0.573, 0.298) and the triple person-times caliper and UBM (- 1.15, - 0.605). This indicated a strong agreement between the triple person-times caliper and Pentacam HR and a lack of agreement between the triple person-times caliper and UBM. Triple person-times caliper measurements offer excellent maneuverability, practicality, and reliable outcomes for determining ICL vaults. Measurements obtained using the triple-person caliper were less differece than those obtained using the Pentacam HR.
Collapse
Affiliation(s)
- Ting-Ting Dan
- Department of Ophthalmology, Affiliated Hospital of Zunyi Medical University, Zunyi, 563000, Guizhou Province, China
- Guizhou Eye Hospital, Zunyi, 563000, Guizhou Province, China
- Guizhou Provincial Branch of National Eye Disease Clinical Research Center, Zunyi, 563000, Guizhou Province, China
- Special Key Laboratory of Ocular Diseases of Guizhou Province, Zunyi Medical University, Zunyi, 563000, Guizhou Province, China
| | - Tai-Xiang Liu
- Department of Ophthalmology, Affiliated Hospital of Zunyi Medical University, Zunyi, 563000, Guizhou Province, China.
- Guizhou Eye Hospital, Zunyi, 563000, Guizhou Province, China.
- Guizhou Provincial Branch of National Eye Disease Clinical Research Center, Zunyi, 563000, Guizhou Province, China.
- Special Key Laboratory of Ocular Diseases of Guizhou Province, Zunyi Medical University, Zunyi, 563000, Guizhou Province, China.
- Department of Ophthalmology, The Affiliated Hospital of Zunyi Medical University, No. 149 Dalian Road, Huichuan District, Zunyi, 563003, Guizhou Province, China.
| | - Zong-Ze Li
- Department of Ophthalmology, Affiliated Hospital of Zunyi Medical University, Zunyi, 563000, Guizhou Province, China
| | - Ceng-Peng Liang
- Special Key Laboratory of Ocular Diseases of Guizhou Province, Zunyi Medical University, Zunyi, 563000, Guizhou Province, China
| | - Fa-Yuan Li
- Special Key Laboratory of Ocular Diseases of Guizhou Province, Zunyi Medical University, Zunyi, 563000, Guizhou Province, China
| |
Collapse
|
2
|
Ning J, Zhang Q, Liang W, Zhang R, Xing Z, Jin L, Zhang L. Bibliometric and visualized analysis of posterior chamber phakic intraocular lens research between 2003 and 2023. Front Med (Lausanne) 2024; 11:1391327. [PMID: 38651068 PMCID: PMC11034429 DOI: 10.3389/fmed.2024.1391327] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2024] [Accepted: 03/27/2024] [Indexed: 04/25/2024] Open
Abstract
Introduction Myopia is causing a major public health concern, with its prevalence increasing globally. This study aimed to discuss posterior chamber phakic intraocular lens (pIOL) research publication trends and hotspots over the past 20 years. Methods Bibliometric analysis was performed using the Web Science Core Collection to investigate posterior-chamber pIOL research publication trends. The extracted records were analyzed, and a knowledge map was built using VOSviewer v.1.6.20. The analysis included visualizing the annual publication count, countries/regions distribution, international and institutional collaborations, author productivity, and journal contribution, in addition to identifying knowledge bases and hotspots. Burst keywords were extracted using CiteSpace v.6.1.R. Results In total, 791 articles on posterior chamber pIOLs published between 2003 and 2023 were retrieved. China had the highest number of publications, whereas Japanese papers received the most citations. Fudan University had the highest number of publications, with articles from Kitasato University having the highest number of citations. Regarding individual research, Xingtao Zhou has published the most significant number of articles, and Shimizu Kimiya had the highest number of citations. The top productive/influential journal was 'Journal of Cataract & Refractive Surgery'. The top cited references primarily focused on reporting the clinical outcomes of implantable collamer lens (ICL) for individuals with moderate to high myopia. The keywords primarily formed four clusters: posterior chamber pIOL clinical outcomes for myopic astigmatism correction, posterior chamber pIOL implantation complications, ICL size selection and postoperative vault predictions, and postoperative visual quality following posterior chamber pIOL implantation. Conclusion This study presents the first bibliometric analysis of research trends in posterior chamber pIOL over the past two decades. We investigated the current state and emerging trends of global collaboration and research focal points in this field, offering fresh insights and guidance for researchers.
Collapse
Affiliation(s)
- Jiliang Ning
- Department of Ophthalmology, The Third People’s Hospital of Dalian, Dalian, China
- Department of Ophthalmology, Dalian Municipal Eye Hospital, Dalian, China
- Liaoning Provincial Key Laboratory of Cornea and Ocular Surface Diseases, Dalian, China
- Liaoning Provincial Optometry Technology Engineering Research Center, Dalian, China
| | - Qiaosi Zhang
- Department of Ophthalmology, The Third People’s Hospital of Dalian, Dalian, China
- Department of Ophthalmology, Dalian Municipal Eye Hospital, Dalian, China
- Liaoning Provincial Key Laboratory of Cornea and Ocular Surface Diseases, Dalian, China
- Liaoning Provincial Optometry Technology Engineering Research Center, Dalian, China
| | - Wei Liang
- Department of Ophthalmology, The Third People’s Hospital of Dalian, Dalian, China
- Department of Ophthalmology, Dalian Municipal Eye Hospital, Dalian, China
- Liaoning Provincial Key Laboratory of Cornea and Ocular Surface Diseases, Dalian, China
- Liaoning Provincial Optometry Technology Engineering Research Center, Dalian, China
| | - Rui Zhang
- Department of Ophthalmology, The Third People’s Hospital of Dalian, Dalian, China
- Department of Ophthalmology, Dalian Municipal Eye Hospital, Dalian, China
- Liaoning Provincial Key Laboratory of Cornea and Ocular Surface Diseases, Dalian, China
- Liaoning Provincial Optometry Technology Engineering Research Center, Dalian, China
| | - Zequn Xing
- Department of Ophthalmology, The Third People’s Hospital of Dalian, Dalian, China
- Department of Ophthalmology, Dalian Municipal Eye Hospital, Dalian, China
- Liaoning Provincial Key Laboratory of Cornea and Ocular Surface Diseases, Dalian, China
- Liaoning Provincial Optometry Technology Engineering Research Center, Dalian, China
| | - Lin Jin
- Department of Ophthalmology, The Third People’s Hospital of Dalian, Dalian, China
- Department of Ophthalmology, Dalian Municipal Eye Hospital, Dalian, China
- Liaoning Provincial Key Laboratory of Cornea and Ocular Surface Diseases, Dalian, China
- Liaoning Provincial Optometry Technology Engineering Research Center, Dalian, China
| | - Lijun Zhang
- Department of Ophthalmology, The Third People’s Hospital of Dalian, Dalian, China
- Department of Ophthalmology, Dalian Municipal Eye Hospital, Dalian, China
- Liaoning Provincial Key Laboratory of Cornea and Ocular Surface Diseases, Dalian, China
- Liaoning Provincial Optometry Technology Engineering Research Center, Dalian, China
| |
Collapse
|
3
|
Thompson V, Cummings AB, Wang X. Implantable Collamer Lens Procedure Planning: A Review of Global Approaches. Clin Ophthalmol 2024; 18:1033-1043. [PMID: 38601168 PMCID: PMC11005927 DOI: 10.2147/opth.s456397] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2023] [Accepted: 03/21/2024] [Indexed: 04/12/2024] Open
Abstract
More than 2 million implantable collamer lenses (ICLs) have been implanted worldwide. With a central port to improve aqueous flow through the ICL, the latest iteration of this phakic intraocular lens (pIOL) has been shown to have stable outcomes with very low rates of adverse events. However, correct planning and ICL size selection continue to be important to achieve an optimal vault. Shallow or excessive vaults are not complications in and of themselves but may increase the risk of complications. Historically, surgeons have relied on measurements of anterior chamber depth (ACD) and manual, caliper-measured white-to-white (WTW) distance to select the ICL size. New diagnostic and imaging technologies such as optical coherence tomography (OCT) and ultrasound biomicroscopy (UBM) provide additional opportunities for visualization and measurement of the intraocular dimensions involved in phakic intraocular lens implantation, including sulcus-to-sulcus (STS) and angle-to-angle (ATA) diameters. This paper reviews various approaches to ICL planning and sizing that have been published in the peer-reviewed literature, all of which produce acceptable results for predicting vault and size selection. Surgeons may also want to identify a methodology for patient evaluation and ICL size selection that best aligns with their personal preferences, diagnostic technology, and familiarity with analytical optimization tools.
Collapse
Affiliation(s)
- Vance Thompson
- Vance Thompson Vision, Sioux Falls, SD, USA
- Department of Ophthalmology, University of South Dakota Sanford School of Medicine, Vermillion, SD, USA
| | | | - Xiaoying Wang
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, People’s Republic of China
- NHC Key Laboratory of Myopia, Fudan University, Shanghai, People’s Republic of China
- Shanghai Research Center of Ophthalmology and Optometry, Eye & ENT Hospital, Fudan University, Shanghai, People’s Republic of China
| |
Collapse
|
4
|
Swaminathan U, Daigavane S. Comparative Analysis of Visual Outcomes and Complications in Intraocular Collamer Lens, Small-Incision Lenticule Extraction, and Laser-Assisted In Situ Keratomileusis Surgeries: A Comprehensive Review. Cureus 2024; 16:e58718. [PMID: 38779265 PMCID: PMC11110473 DOI: 10.7759/cureus.58718] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2024] [Accepted: 04/22/2024] [Indexed: 05/25/2024] Open
Abstract
This review provides a comparative analysis of visual outcomes and complications associated with three prominent refractive surgical techniques: intraocular collamer lens (ICL) implantation, small-incision lenticule extraction (SMILE), and laser-assisted in situ keratomileusis (LASIK). Refractive surgeries aim to correct myopia, hyperopia, and astigmatism, offering patients an alternative to corrective lenses. The review highlights the importance of comparing these procedures to guide clinical decision-making effectively. Each technique is described, emphasizing its unique advantages and considerations. While LASIK remains widely favored for its rapid visual recovery and high patient satisfaction, ICL is suitable for patients with higher refractive errors or corneal irregularities. Although relatively newer, SMILE shows promise with potential benefits such as corneal biomechanical stability and a reduced risk of dry eye syndrome. However, each procedure carries its distinct complications, reinforcing the need for personalized patient care and informed decision-making. Understanding these techniques' relative efficacy and safety profiles is essential for optimizing outcomes and enhancing patient satisfaction. Continued advancements in technology and surgical techniques promise further improvements in refractive surgery outcomes, underscoring the importance of ongoing research and innovation.
Collapse
Affiliation(s)
- Uma Swaminathan
- Ophthalmology, Jawaharlal Nehru Medical College, Datta Meghe Institute of Higher Education & Research, Wardha, IND
| | - Sachin Daigavane
- Ophthalmology, Jawaharlal Nehru Medical College, Datta Meghe Institute of Higher Education & Research, Wardha, IND
| |
Collapse
|
5
|
Reinstein DZ, MacGregor C, Archer TJ, Gupta R, Potter JG. A review of posterior chamber phakic intraocular lenses. Curr Opin Ophthalmol 2024; 35:138-146. [PMID: 38059758 DOI: 10.1097/icu.0000000000001018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/08/2023]
Abstract
PURPOSE OF REVIEW Posterior chamber phakic intraocular lenses (pIOLs) are increasing in popularity as a viable alternative to laser refractive surgery. The purpose of this review is to evaluate the recent updates to pIOLs and to assess the advancements and safety of the procedure. RECENT FINDINGS Accurate lens sizing is the key determinant to suitable vault prediction, advancements to sizing formulae including the use of very high frequency (VHF) digital ultrasound and the application of artificial intelligence and machine learning has led to improved vault prediction and safety. The introduction of the central aquaport has been shown to reduce the formation of cataract and is now adopted in most myopic pIOLs. Recently published studies have demonstrated that pIOLs have an excellent safety profile with no increased risk of retinal detachment or endothelial cell loss. Advancements have led to the introduction of extended depth of focus pIOLs for the correction of presbyopia, further research is required to evaluate the efficacy of new lens designs. SUMMARY pIOL surgery is experiencing traction with improved lens design and increased lenses choices such as larger optical zone and presbyopic options. Accuracy of implantable collamer lens sizing is paramount to the safety and clinical outcomes, greater predictability is likely to encourage more posterior chamber pIOL users due to fewer sizing related complications.
Collapse
Affiliation(s)
- Dan Z Reinstein
- Reinstein Vision
- London Vision Clinic, EuroEyes Group, London, UK
- Columbia University Medical Center, New York, USA
- Sorbonne Université, Paris, France
- Biomedical Science Research Institute, Ulster University, Coleraine, UK
| | | | - Timothy J Archer
- Reinstein Vision
- London Vision Clinic, EuroEyes Group, London, UK
| | - Ruchi Gupta
- Reinstein Vision
- London Vision Clinic, EuroEyes Group, London, UK
| | - Joseph G Potter
- Reinstein Vision
- London Vision Clinic, EuroEyes Group, London, UK
| |
Collapse
|
6
|
Gong D, Deng S, Dang K, Yan Z, Wang J. Causes and management strategies for elevated intraocular pressure after implantable collamer lens implantation. Front Med (Lausanne) 2024; 11:1351272. [PMID: 38384405 PMCID: PMC10879591 DOI: 10.3389/fmed.2024.1351272] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2023] [Accepted: 01/25/2024] [Indexed: 02/23/2024] Open
Abstract
With the widespread application of Implantable Collamer Lens (ICL) implantation surgery in the field of myopia correction, a comprehensive understanding of its potential complications, especially those related to intraocular pressure (IOP), becomes crucial. This article systematically reviews various complications that may lead to IOP elevation after ICL surgery. Firstly, common complications after ICL surgery, including residual viscoelastic, steroid response, and excessive vault of the ICL, are detailed, emphasizing their potential impact on intraocular pressure. Regarding residual viscoelastic, we delve into its direct relationship with postoperative elevated IOP and possible preventive measures. For steroid response, we stress the importance of timely adjustment of steroid therapy and monitoring intraocular pressure. Additionally, excessive vault of the ICL is considered a significant potential issue, and we elaborate on its mechanism and possible management methods. In further discussion, we focus on relatively rare complications such as Toxic Anterior Segment Syndrome (TASS), Urrets-Zavalia Syndrome (UZS), Pigment Dispersion Syndrome (PDS), and malignant glaucoma. For these relatively rare complications, this review thoroughly explores their potential mechanisms, emphasizes the importance of prevention, and provides guidance for early diagnosis and treatment. This is a comprehensible review that aims to offer eye care professionals a comprehensive understanding and effective management guidance for complications of elevated IOP after ICL surgery, ultimately providing optimal care for patients' visual health.
Collapse
Affiliation(s)
- Di Gong
- Shenzhen Eye Hospital, Jinan University, Shenzhen Eye Institute, Shenzhen, Guangdong, China
| | - Simin Deng
- The 2nd Clinical Medical College (Shenzhen People's Hospital) of Jinan University, Shenzhen, China
| | - Kuanrong Dang
- Shenzhen Eye Hospital, Jinan University, Shenzhen Eye Institute, Shenzhen, Guangdong, China
| | - Zonghui Yan
- Shenzhen Eye Hospital, Jinan University, Shenzhen Eye Institute, Shenzhen, Guangdong, China
| | - Jiantao Wang
- Shenzhen Eye Hospital, Jinan University, Shenzhen Eye Institute, Shenzhen, Guangdong, China
| |
Collapse
|
7
|
Albo C, Nasser T, Szynkarski DT, Nguyen N, Mueller B, Libfraind L, Parkhurst G. A Comprehensive Retrospective Analysis of EVO/EVO+ Implantable Collamer Lens: Evaluating Refractive Outcomes in the Largest Single Center Study of ICL Patients in the United States. Clin Ophthalmol 2024; 18:69-78. [PMID: 38223817 PMCID: PMC10787571 DOI: 10.2147/opth.s440578] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2023] [Accepted: 12/05/2023] [Indexed: 01/16/2024] Open
Abstract
Purpose We evaluate visual outcomes in patients with EVO/EVO+™ (posterior chamber phakic intraocular lens with a central port) within approved United States (US) age and refractive range indications. Patients and Methods This single-center retrospective study evaluated one-month, single-center postoperative data for 225 eyes meeting inclusion criteria and undergoing EVO/EVO+ implantation from April to October 2022. Data included lens size (mm), lens power (diopters of spherical and cylindrical power), preoperative best corrected visual acuity, preoperative spherical equivalent from manifest refraction, achieved postoperative uncorrected visual acuity, postoperative refraction, intraocular pressure (mmHg), and adverse events. Results A total of 225 eyes underwent EVO/EVO+ Implantable Collamer Lens (ICL) implantation from April to October 2022, with 51.5% receiving toric lenses. The most common ICL size was 12.6mm (56.4%), followed by 13.2mm (27.5%), 12.1mm (15.1%), and 13.7mm (0.9%). Among patients with preoperative BCVA of 20/20 or better (149 eyes), 95.2% achieved postoperative UCVA of 20/20 or better, and 99.3% achieved UCVA of 20/25 or better at postoperative month one. About 75% of eyes were within a spherical equivalent target of ±0.50 D and 94% within ±1.00 D. Toric ICLs were implanted in 116 eyes (51.8%). Of these, anticipated residual cylinder >1 diopter was seen in 21 eyes (18.1%) resulting in three rotations, three explants, and three laser vision correction (LVC) enhancements. The postoperative adjustment rate (including rotations, exchanges, and LVC enhancement) was minimal (4.8%). Incidence of major adverse events was 0%. Conclusion Our study, the largest US single-center analysis of EVO/EVO+ ICL implantation, demonstrates strong early results and infrequent adverse events, supporting ICL safety and effectiveness. High predictability and favorable visual outcomes, including 20/20 or better, highlight the reliability of this technology. Despite study limitations, our findings underscore this technology's effectiveness. Future research should refine patient criteria and assess long-term outcomes in this evolving landscape.
Collapse
Affiliation(s)
- Camila Albo
- Department of Ophthalmology, University of Texas Health San Antonio, San Antonio, TX, USA
| | - Taj Nasser
- Department of Ophthalmology, Parkhurst NuVision, San Antonio, TX, USA
| | | | - Ngoc Nguyen
- Department of Ophthalmology, Medical City Plano, Plano, TX, USA
| | - Brett Mueller
- Department of Ophthalmology, Parkhurst NuVision, San Antonio, TX, USA
- Department of Ophthalmology, Mueller Vision, Fort Worth, TX, USA
| | - Lauren Libfraind
- Department of Ophthalmology, Parkhurst NuVision, San Antonio, TX, USA
| | - Gregory Parkhurst
- Department of Ophthalmology, Parkhurst NuVision, San Antonio, TX, USA
| |
Collapse
|
8
|
Hjortdal J. Refractive and cataract surgery beyond VISION2020. Indian J Ophthalmol 2024; 72:3-5. [PMID: 38131561 PMCID: PMC10841810 DOI: 10.4103/ijo.ijo_2767_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2023] Open
Affiliation(s)
- Jesper Hjortdal
- Department of Ophthalmology, Aarhus University Hospital, Aarhus, Denmark. E-mail:
| |
Collapse
|
9
|
Moshirfar M, Han KD, Jaafar MA, Santos JM, Theis JS, Stoakes IM, Hoopes PC. Comparative evaluation of multiple nomograms for predicting postoperative vault after implantable collamer lens surgery. J Cataract Refract Surg 2024; 50:64-71. [PMID: 37702514 DOI: 10.1097/j.jcrs.0000000000001304] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2023] [Accepted: 08/29/2023] [Indexed: 09/14/2023]
Abstract
PURPOSE To compare the vault predictability of most available implantable collamer lens (ICL) sizing nomograms and identify which preoperative measurements are predictive of vault. SETTING Private practice in Draper, Utah. DESIGN Retrospective chart review. METHODS This study was a retrospective analysis of 209 eyes of 106 patients who underwent STAAR Surgical ICL implantation. Analyses were performed based on the availability of preoperative parameters, varying the number of eyes for each test. Mean absolute error (MAE) of predicted vs actual postoperative vault was calculated for each nomogram. The frequency of Kim, Rocamora (least absolute shrinkage and selection operator-optical coherence tomography), Russo, and Reinstein recommending the correct ICL size in instances when Parkhurst, optimized white-to-white (WTW), and STAAR could not recommend a definitive ICL size was determined. Univariate and multivariate linear regression analysis was performed between preoperative measurements and vault. RESULTS The Kim, Rocamora, Russo, and Reinstein nomograms had significantly lower MAE of predicted vs actual postoperative vault than the KSV2 and Nakamura V3 nomograms. The Russo formula most frequently recommended the correct ICL size when the Parkhurst, Optimized WTW, and STAAR nomograms could not provide ICL size recommendations. At the 0.05 significance level, anterior chamber depth (ACD), ciliary body inner diameter (CBID), and pupil diameter were the parameters found to have significant correlation with postoperative vault. CONCLUSIONS The Kim, Rocamora, Russo, and Reinstein nomograms were the most predictive of vault. Additionally, ACD, CBID, and pupil diameter were found to be significantly correlated with vault and should be considered for use in future ICL sizing nomograms.
Collapse
Affiliation(s)
- Majid Moshirfar
- From the Hoopes Vision Research Center, Hoopes Vision, Draper, Utah (Moshirfar, Hoopes); John A. Moran Eye Center, University of Utah School of Medicine, Salt Lake City, Utah (Moshirfar); Utah Lions Eye Bank, Murray, Utah (Moshirfar); University of Arizona College of Medicine Phoenix, Phoenix, Arizona (Han, Jaafar, Santos, Theis); Pacific Northwest University of Health Sciences, Yakima, Washington (Stoakes)
| | | | | | | | | | | | | |
Collapse
|
10
|
Naujokaitis T, Auffarth GU, Łabuz G, Kessler LJ, Khoramnia R. Diagnostic Techniques to Increase the Safety of Phakic Intraocular Lenses. Diagnostics (Basel) 2023; 13:2503. [PMID: 37568866 PMCID: PMC10417808 DOI: 10.3390/diagnostics13152503] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Revised: 07/25/2023] [Accepted: 07/25/2023] [Indexed: 08/13/2023] Open
Abstract
Preoperative and postoperative diagnostics play an important role in ensuring the safety of patients with phakic intraocular lenses (pIOLs). The risk of endothelial cell loss can be addressed by regularly measuring the endothelial cell density using specular microscopy and considering the endothelial cell loss rate and the endothelial reserve in accordance with the patient's age when deciding whether to explant a pIOL. The anterior chamber morphometrics, including the anterior chamber depth and the distance between the pIOL and the endothelium, measured using Scheimpflug tomography and anterior segment optical coherence tomography (AS-OCT), can help to assess the risk of the endothelial cell loss. In patients undergoing posterior chamber pIOL implantation, accurate prediction of the vault and its postoperative measurements using AS-OCT or Scheimpflug tomography are important when assessing the risk of anterior subcapsular cataract and secondary glaucoma. Novel approaches based on ultrasound biomicroscopy and AS-OCT have been proposed to increase the vault prediction accuracy and to identify eyes in which prediction errors are more likely. Careful patient selection and regular postoperative follow-up visits can reduce the complication risk and enable early intervention if a complication occurs.
Collapse
Affiliation(s)
| | | | | | | | - Ramin Khoramnia
- Department of Ophthalmology, University of Heidelberg, 69120 Heidelberg, Germany
| |
Collapse
|