Pastor-Pascual F, Orts-Vila P, Tañá-Sanz P, Tañá-Sanz S, Tañá-Rivero P. Clinical Performance of an Omnidirectional Aberration-Free Trifocal Toric Intraocular Lens.
Clin Ophthalmol 2024;
18:2009-2020. [PMID:
39010935 PMCID:
PMC11249071 DOI:
10.2147/opth.s466091]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2024] [Accepted: 06/17/2024] [Indexed: 07/17/2024] Open
Abstract
Purpose
To assess the refractive and visual outcomes at different distances following cataract surgery with implantation of an omnidirectional aberration-free diffractive trifocal toric intraocular lens (IOL).
Methods
A total of 24 patients who underwent bilateral implantation with the TrivaT-aAY IOL were analyzed at 3-4 months post-surgery. Refractive error, monocular and binocular uncorrected and corrected-distance visual acuity (UDVA, CDVA), uncorrected and corrected-distance intermediate visual acuity (UIVA, CDIVA) at 60 cm, uncorrected and corrected-distance near visual acuity (UNVA, CDNVA) at 40 cm, monocular and binocular defocus curve and rotational stability were measured. Patients also completed the Catquest-9SF questionnaire at the last postoperative visit.
Results
The postoperative mean values of binocular logMAR CDVA, CDIVA and CDNVA were -0.06±0.06, 0.05±0.07 and 0.07±0.08, respectively. One hundred percent of patients showed a cumulative binocular CDVA ≥20/25, and 95.83% of patients showed a cumulative binocular CDIVA and CDNVA ≥20/32. The mean postoperative spherical equivalent was 0.07±0.26D and 100% and 97.92% eyes were within ±1.00D and ±0.50D, respectively. The mean postoperative refractive cylinder was -0.22±0.29D and 100% and 89.58% eyes showed a value ≤1.00D and ≤0.50D, respectively. The defocus curves showed a wide range of useful vision, with visual acuity values >0.2 logMAR. Mean absolute IOL rotation was 2.19±2.17 degrees and all eyes had a rotation <10 degrees. For the questionnaire, 95.83% of patients reported being quite satisfied to very satisfied with their vision and about 79.17% did not report any difficulty with their vision in their everyday life. Between 83.33% and 95.83% of patients reported no difficulty performing different tasks. No intra- and postoperative complications were reported during the follow-up.
Conclusion
Our study shows that the TrivaT-aAY IOL provides good visual acuities at all distances and refractive outcomes with excellent rotational stability and with high satisfaction among our patients after its implantation.
Collapse