Berlin A, Fischer NA, Clark ME, Kar D, Swain TA, Martindale RM, McGwin G, Crosson JN, Sloan KR, Owsley C, Curcio CA. Quantitative Autofluorescence at AMD's Beginnings Highlights Retinal Topography and Grading System Differences: ALSTAR2 Baseline. Ophthalmologica 2024:1-13. [PMID: 38599207 DOI: 10.1159/000538696] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2023] [Accepted: 03/24/2024] [Indexed: 04/12/2024]
Abstract
INTRODUCTION The aims of the study were to describe baseline quantitative (short-wavelength) autofluorescence (qAF) findings in a large pseudophakic cohort at age-related macular degeneration (AMD)'s beginnings and to assess qAF8 as an outcome measure and evaluate Age-Related Eye Disease Study (AREDS) and Beckman grading systems. METHODS In the ALSTAR2 baseline cohort (NCT04112667), 346 pseudophakic eyes of 188 persons (74.0 ± 5.5 years) were classified as normal (N = 160 by AREDS, 158 by Beckman), early AMD (eAMD) (N = 104, 66), and intermediate AMD (iAMD) (N = 82, 122). Groups were compared via mean qAF intensities in a 6°-8° annulus (qAF8) and maps of differences between observations and the overall mean, divided by standard deviation (Z-score). RESULTS qAF8 did not differ significantly among diagnostic groups by either stratification (p = 0.0869 AREDS; p = 0.0569 by Beckman). Notably, 45 eyes considered eAMD by AREDS became iAMD by Beckman. For AREDS-stratified eyes, Z-score maps showed higher centrally located qAF for normal, near the mean in eAMD, and lower values for iAMD. Maps deviated from this pattern for Beckman-stratified eyes. CONCLUSIONS In a large sample of pseudophakic eyes, qAF8 does not differ overall from normal aging to iAMD but also does not capture the earliest AMD activity in the macula lutea. AREDS classification gives results more consistent with a slow decline in histologic autofluorescence than Beckman classification.
Collapse
Affiliation(s)
- Andreas Berlin
- Department of Ophthalmology and Visual Sciences, Heersink School of Medicine, University of Alabama at Birmingham, Birmingham, Alabama, USA,
- University Hospital Würzburg, Würzburg, Germany,
| | - Nathan A Fischer
- Department of Ophthalmology and Visual Sciences, Heersink School of Medicine, University of Alabama at Birmingham, Birmingham, Alabama, USA
- Retina Consultants of Alabama, Birmingham, Alabama, USA
| | - Mark E Clark
- Department of Ophthalmology and Visual Sciences, Heersink School of Medicine, University of Alabama at Birmingham, Birmingham, Alabama, USA
| | - Deepayan Kar
- Department of Ophthalmology and Visual Sciences, Heersink School of Medicine, University of Alabama at Birmingham, Birmingham, Alabama, USA
| | - Thomas A Swain
- Department of Ophthalmology and Visual Sciences, Heersink School of Medicine, University of Alabama at Birmingham, Birmingham, Alabama, USA
| | - Richard M Martindale
- Department of Ophthalmology and Visual Sciences, Heersink School of Medicine, University of Alabama at Birmingham, Birmingham, Alabama, USA
- Retina Consultants of Alabama, Birmingham, Alabama, USA
| | - Gerald McGwin
- Department of Ophthalmology and Visual Sciences, Heersink School of Medicine, University of Alabama at Birmingham, Birmingham, Alabama, USA
- Department of Epidemiology, School of Public Health, University of Alabama at Birmingham, Birmingham, Alabama, USA
| | - Jason N Crosson
- Department of Ophthalmology and Visual Sciences, Heersink School of Medicine, University of Alabama at Birmingham, Birmingham, Alabama, USA
- Retina Consultants of Alabama, Birmingham, Alabama, USA
| | - Kenneth R Sloan
- Department of Ophthalmology and Visual Sciences, Heersink School of Medicine, University of Alabama at Birmingham, Birmingham, Alabama, USA
| | - Cynthia Owsley
- Department of Ophthalmology and Visual Sciences, Heersink School of Medicine, University of Alabama at Birmingham, Birmingham, Alabama, USA
| | - Christine A Curcio
- Department of Ophthalmology and Visual Sciences, Heersink School of Medicine, University of Alabama at Birmingham, Birmingham, Alabama, USA
| |
Collapse
|
2
|
Fernández-Vigo JI, Macarro-Merino A, De Moura-Ramos JJ, Alvarez-Rodriguez L, Burgos-Blasco B, Novo-Bujan J, Ortega-Hortas M, Fernández-Vigo JÁ. Comparative study of the glistening between four intraocular lens models assessed by OCT and deep learning. J Cataract Refract Surg 2024; 50:37-42. [PMID: 37702457 DOI: 10.1097/j.jcrs.0000000000001316] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2023] [Accepted: 09/08/2023] [Indexed: 09/14/2023]
Abstract
PURPOSE To evaluate the glistening in 4 different models of intraocular lenses (IOLs) using optical coherence tomography (OCT) and deep learning (DL). SETTING Centro Internacional de Oftalmología Avanzada (Madrid, Spain). DESIGN Cross-sectional study. METHODS 325 eyes were assessed for the presence and severity of glistening in 4 IOL models: ReSTOR+3 SN6AD1 (n = 41), SN60WF (n = 110), PanOptix TFNT (n = 128) and Vivity DFT015 (n = 46). The presence of glistening was analyzed using OCT, identifying the presence of hyperreflective foci (HRF) in the central area of the IOL. A manual and an original DL-based quantification algorithm designed for this purpose was applied. RESULTS Glistening was detected in 22 (53.7%) ReSTOR SN6AD1, 44 (40%) SN60WF, 49 (38.3%) PanOptix TFNT, and 4 (8.7%) Vivity DFT015 IOLs, when any grade was considered. In the comparison of the different types of IOLs, global glistening measured as total HRF was 17.3 ± 25.9 for the ReSTOR+3; 9.3 ± 15.7 for the SN60WF; 6.9 ± 10.5 for the PanOptix; and 1.2 ± 2.6 for the Vivity ( P < .05). There was excellent agreement between manual and DL-based quantification (≥0.829). CONCLUSIONS It is possible to quantify, classify and compare the glistening severity in different IOL models using OCT images in a simple and objective manner with a DL algorithm. In the comparative study, the Vivity presented the lowest severity of glistening.
Collapse
Affiliation(s)
- José Ignacio Fernández-Vigo
- From the Centro Internacional de Oftalmología Avanzada, Madrid, Spain (J.I. Fernández-Vigo, Macarro-Merino, J.Á. Fernández-Vigo); Department of Ophthalmology, Hospital Clínico San Carlos, Instituto de Investigación Sanitaria (IdISSC), Madrid, Spain (J.I. Fernández-Vigo, Burgos-Blasco); Department of Computational, Centro de Investigacion CITIC, Universidade da Coruña, A Coruña, Spain (De Moura-Ramos, Alvarez-Rodriguez, Novo-Bujan, Ortega-Hortas); Department of Computational, VARPA Research Group, Instituto de Investigación Biomédica de A Coruña (INIBIC), Universidade da Coruña, A Coruña, Spain (De Moura-Ramos, Alvarez-Rodriguez, Novo-Bujan, Ortega-Hortas); Department of Ophthalmology, Universidad de Extremadura, Badajoz, Spain (J.Á. Fernández-Vigo)
| | | | | | | | | | | | | | | |
Collapse
|
3
|
Fernández-Vigo JI, Serrano González-Peramato MT, Nunila Gómez-de-Liaño C, Sánchez-Guillén I, Fernández-Vigo JÁ, Macarro-Merino A. Glistening on intraocular lenses: A review. ARCHIVOS DE LA SOCIEDAD ESPANOLA DE OFTALMOLOGIA 2023; 98:493-506. [PMID: 37369324 DOI: 10.1016/j.oftale.2023.06.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/14/2023] [Accepted: 06/07/2023] [Indexed: 06/29/2023]
Abstract
The glistening in intraocular lenses (IOLs) is a phenomenon in which tiny water-filled microvacuoles (MVs) form within the IOL material, causing light to scatter and create a sparkling or shimmering effect. The presence of glistening is common in many types of IOL materials and models and has been extensively studied in recent years to determine its incidence, risk factors, evolution, and possible clinical relevance. Classically, it has been studied in vitro in the laboratory or by means of photography obtained with a slit lamp, but these were techniques that required either specific technology or an expert explorer, complex image processing, and required a lot of time. In recent years, proposals based on the Scheimpflug camera and optical coherence tomography have emerged to try to simplify the analysis of glistening in IOLs. It has been described that the manufacturing process, the hydrophobic acrylic material, or the time since surgery are risk factors for the appearance of glistening. In addition, many issues related to this phenomenon are still unknown, such as not knowing from what number of points or their size they may have relevance to visual function since different optical phenomena related to glistening have been described on the IOLs.
Collapse
Affiliation(s)
- J I Fernández-Vigo
- Servicio de Oftalmología, Hospital Clínico San Carlos, Instituto de Investigación Sanitaria (IdISSC), Madrid, Spain; Centro Internacional de Oftalmología Avanzada, Madrid, Spain.
| | | | - C Nunila Gómez-de-Liaño
- Servicio de Oftalmología, Hospital Clínico San Carlos, Instituto de Investigación Sanitaria (IdISSC), Madrid, Spain
| | - I Sánchez-Guillén
- Servicio de Oftalmología, Hospital Perpetuo Socorro, Badajoz, Spain; Centro Internacional de Oftalmología Avanzada, Badajoz, Spain
| | - J Á Fernández-Vigo
- Centro Internacional de Oftalmología Avanzada, Madrid, Spain; Centro Internacional de Oftalmología Avanzada, Badajoz, Spain; Departamento de Oftalmología, Facultad de Medicina, Universidad de Extremadura, Badajoz, Spain
| | - A Macarro-Merino
- Centro Internacional de Oftalmología Avanzada, Madrid, Spain; Centro Internacional de Oftalmología Avanzada, Badajoz, Spain
| |
Collapse
|
4
|
Objective Classification of Glistening in Implanted Intraocular Lenses Using Optical Coherence Tomography: Proposal for a New Classification and Grading System. J Clin Med 2023; 12:jcm12062351. [PMID: 36983351 PMCID: PMC10057385 DOI: 10.3390/jcm12062351] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2023] [Revised: 03/10/2023] [Accepted: 03/15/2023] [Indexed: 03/22/2023] Open
Abstract
Purpose: To propose a classification of the glistening in intraocular lenses (IOL) using swept-source optical coherence tomography (SS-OCT) by means of a simple, objective and reproducible method that allows the quantification of the presence and severity of glistening. Methods: A cross-sectional study on a sample of 150 eyes of 150 patients who underwent cataract surgery in at least 600 days before the exam and attended a routine examination. Each subject was examined by SS-OCT after pupil dilation, identifying the presence of glistening or hyperreflective foci (HRF) in the central area of the IOL. The degree of glistening was classified into four categories: 0: ≤5 HRF; 1: 6 to 15 HRF; 2: 16 to 30 HRF; and 3: >30 HRF. The intra and interobserver reproducibility (intraclass correlation coefficient, ICC) in the quantification and classification of the glistening were calculated. The correlation between the horizontal and vertical scan of the IOL was also assessed. Results: Glistening was present in the IOL in 42.7% of the patients. The mean number of HRF or glistening microvacuoles was 10.4 ± 26.2 (range 0 to 239). In total, 63.3% of the IOLs had a grade 0, 20% grade a 1, 6.7% grade a 2 and 10% a grade 3. The intraobserver and interobserver reproducibility were very high, both for the absolute quantification of the glistening (ICC ≥ 0.994) and for the severity scale (ICC ≥ 0.967). There was an excellent correlation in the quantification of the IOL glistening between the horizontal and vertical scans (R ≥ 0.834; p < 0.001). Conclusions: The use of SS-OCT makes it possible to identify, quantify and classify IOL glistening in a simple, objective and reproducible way. This technique could provide relevant information for the study of the glistening on IOLs.
Collapse
|
5
|
Hecht I, Kanclerz P, Tuuminen R. Secondary outcomes of lens and cataract surgery: More than just “best-corrected visual acuity”. Prog Retin Eye Res 2022:101150. [DOI: 10.1016/j.preteyeres.2022.101150] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2022] [Revised: 11/07/2022] [Accepted: 11/20/2022] [Indexed: 12/12/2022]
|
6
|
Oshika T, Sasaki N. One-year multicenter evaluation of a new hydrophobic acrylic intraocular lens with hydroxyethyl methacrylate in an automated preloaded delivery system. J Cataract Refract Surg 2022; 48:275-279. [PMID: 34261986 PMCID: PMC8865199 DOI: 10.1097/j.jcrs.0000000000000746] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2021] [Accepted: 06/30/2021] [Indexed: 11/26/2022]
Abstract
PURPOSE To assess a single-piece monofocal hydrophobic acrylic intraocular lens (IOL) with hydroxyethyl methacrylate (HEMA) (Clareon) contained in automated preloaded delivery system (AutonoMe). SETTING 18 surgical sites in Japan. DESIGN Observational study. METHODS In patients undergoing phacoemulsification and IOL implantation of a new hydrophobic acrylic IOL using an automated injector, clinical data were collected preoperatively and at 1 day, 1 week, and 1 month, 6 months, and 12 months postoperatively. The degree of glistenings was graded on a 4-point scale. The surgeons rated usability and performance of the IOL delivery system on a 5-point scale. RESULTS The study enrolled 384 eyes of 384 patients, ranging in age from 41 to 93 (73.8 ± 8.2, mean ± SD) years. The percentage of eyes with corrected distance visual acuity of 20/25 or better at 1 day, 1 week, and 1 month, 6 months, and 12 months postoperatively was 82.6%, 91.9%, 92.8%, 96.6%, and 95.2%, respectively. Refractive error was within 1.0 diopter in approximately 90% of cases. No glistenings were found in all cases throughout the study period. The rate of Nd:YAG laser posterior capsulotomy was 0.9% at 1 year. The IOL delivery system received high ratings on its usability and performance by the surgeons. CONCLUSIONS The new hydrophobic acrylic IOL with HEMA showed excellent visual and refractive outcomes without developing glistenings throughout the 1-year study period. The surgeons gave high marks for usability and performance of the automated preloaded delivery system.
Collapse
|
7
|
Randomized contralateral comparison of visual outcomes following implantation of two monofocal aspherical intraocular lenses after cataract surgery. Int Ophthalmol 2022; 42:1563-1571. [DOI: 10.1007/s10792-021-02150-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2021] [Accepted: 12/17/2021] [Indexed: 10/19/2022]
|
8
|
Tandogan T, Auffarth GU, Choi CY, Son HS, Khoramnia R. Comparative analysis of in vitro accelerated glistening formation in foldable hydrophobic intraocular lenses. Int Ophthalmol 2021; 41:3073-3080. [PMID: 34013467 PMCID: PMC8364527 DOI: 10.1007/s10792-021-01870-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2020] [Accepted: 04/15/2021] [Indexed: 01/30/2023]
Abstract
PURPOSE To analyse and compare the propensity to form glistenings in 4 different types of hydrophobic acrylic intraocular lenses (IOLs): Alcon AcrySof ® MA60AC, HOYA iSert® PC-60AD, Bausch&Lomb enVista, and Kowa Avansee™ PU6A. METHODS We used an accelerated laboratory method to create glistenings. IOLs were first immersed in saline at 45 °C for 24 h and then at 37 °C for 2.5 h. Microvacuole (MV) density and size were documented and calculated using an image analysis program. RESULTS Median density of glistenings [MV/mm2] for Alcon AcrySof ® MA60AC was 623 (range 507-804), for HOYA iSert® PC-60AD 1358 (range 684-2699), for Bausch&Lomb enVista 2 (range 1-2), and for Kowa Avansee™ PU6A 1 (range 1-4). The prevailing MV size was: 0-5 µm for Hoya IOLs, 5-10 µm for Alcon IOLs, 20-50 µm for Bausch&Lomb IOLs, and 5-50 µm for Kowa IOLs. CONCLUSIONS Glistenings could be induced in all studied IOLs using the accelerated laboratory method. The Alcon AcrySof ® MA60AC and HOYA iSert® PC-60AD IOLs showed MV of high density, while the glistenings in the Hoya IOLs were smaller in size compared to the Alcon IOLs. The MV density was minimal in the Bausch&Lomb enVista and Kowa Avansee™ PU6A IOLs. The propensity of the Alcon AcrySof ® MA60AC IOLs to form glistenings in vitro correlated with the findings of clinical results that are already published.
Collapse
Affiliation(s)
- Tamer Tandogan
- The David J. Apple International Laboratory for Ocular Pathology and International Vision Correction Research Centre (IVCRC), Department of Ophthalmology, University of Heidelberg, INF 400, 69120 Heidelberg, Germany
| | - Gerd U. Auffarth
- The David J. Apple International Laboratory for Ocular Pathology and International Vision Correction Research Centre (IVCRC), Department of Ophthalmology, University of Heidelberg, INF 400, 69120 Heidelberg, Germany
| | - Chul Young Choi
- Department of Ophthalmology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Hyeck-Soo Son
- The David J. Apple International Laboratory for Ocular Pathology and International Vision Correction Research Centre (IVCRC), Department of Ophthalmology, University of Heidelberg, INF 400, 69120 Heidelberg, Germany
| | - Ramin Khoramnia
- The David J. Apple International Laboratory for Ocular Pathology and International Vision Correction Research Centre (IVCRC), Department of Ophthalmology, University of Heidelberg, INF 400, 69120 Heidelberg, Germany
| |
Collapse
|
9
|
Tandogan T, Auffarth GU, Son HS, Merz P, Choi CY, Khoramnia R. In-vitro glistening formation in six different foldable hydrophobic intraocular lenses. BMC Ophthalmol 2021; 21:126. [PMID: 33685428 PMCID: PMC7938589 DOI: 10.1186/s12886-021-01879-6] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Accepted: 02/18/2021] [Indexed: 11/26/2022] Open
Abstract
Background Glistenings describe small, refractile microvacuoles that may arise within the intraocular lens (IOL) material and reduce the patients’ quality of vision. Lenses composed of hydrophobic acrylic material are particularly affected by glistening formation. In this study, we compared the tendency of glistening formation in six different types of hydrophobic acrylic intraocular lenses (IOLs). Methods We used a well-established accelerated laboratory method to develop glistenings in the following IOLs: Vivinex XY1 (Hoya), AcrySof SN60WF (Alcon), Tecnis ZCB00 (AMO), Avansee PN6A (Kowa), Aktis SP NS-60YG (Nidek), and CT Lucia 601P (Zeiss). IOLs were first immersed in saline at 45 °C for 24 h and then at 37 °C for 2.5 h in a water bath. Microvacuole (MV) density and size (Miyata grading) were documented and calculated using an image analysis program. Results The mean glistening density [MV/mm2] and mean Miyata grading (in brackets) were: Vivinex: 11.6 ± 5.7 (0), SN60WF: 264.4 ± 110.3 (2.6), Tecnis: 6.0 ± 2.8 (0), Avansee: 2.2 ± 0.7 (0), Aktis: 851.4 ± 59.4 (3+) and CT Lucia: 71.0 ± 71.6 (1). Conclusions While all tested IOLs showed glistenings with the accelerated laboratory method, the Aktis and SN60WF showed the highest microvacuole density, followed by the CT Lucia. In comparison, the Vivinex, Tecnis, and Avansee IOLs showed far fewer number of glistenings.
Collapse
Affiliation(s)
- Tamer Tandogan
- The David J. Apple International Laboratory for Ocular Pathology and International Vision Correction Research Centre (IVCRC), Department of Ophthalmology, University of Heidelberg, INF 400, 69120, Heidelberg, Germany
| | - Gerd U Auffarth
- The David J. Apple International Laboratory for Ocular Pathology and International Vision Correction Research Centre (IVCRC), Department of Ophthalmology, University of Heidelberg, INF 400, 69120, Heidelberg, Germany.
| | - Hyeck-Soo Son
- The David J. Apple International Laboratory for Ocular Pathology and International Vision Correction Research Centre (IVCRC), Department of Ophthalmology, University of Heidelberg, INF 400, 69120, Heidelberg, Germany
| | - Patrick Merz
- The David J. Apple International Laboratory for Ocular Pathology and International Vision Correction Research Centre (IVCRC), Department of Ophthalmology, University of Heidelberg, INF 400, 69120, Heidelberg, Germany
| | - Chul Young Choi
- Department of Ophthalmology, Kangbuk Samsung Hospital, Sungkyunkwan University, Seoul, South Korea
| | - Ramin Khoramnia
- The David J. Apple International Laboratory for Ocular Pathology and International Vision Correction Research Centre (IVCRC), Department of Ophthalmology, University of Heidelberg, INF 400, 69120, Heidelberg, Germany
| |
Collapse
|
10
|
Watane A, Botsford BW, Sood AB, Williams AM, Xu D, Gupta RR, Conner IP, Sivalingam A, Gupta OP, Ward MS, Mehta S, Cid MD, Crossan A, Sierpina DI, Hwang FS, Rachitskaya A, Ehmann DS, Kovacs KD, Orlin A, Zhang AY, Patel U, Dubovy S, Klufas MA, Patel NA, Sridhar J, Yannuzzi NA. Scleral-Sutured Intraocular Lens Dislocations Secondary to Eyelet Fractures. Am J Ophthalmol 2021; 221:273-278. [PMID: 32777376 DOI: 10.1016/j.ajo.2020.07.049] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2020] [Revised: 07/22/2020] [Accepted: 07/24/2020] [Indexed: 12/11/2022]
Abstract
OBJECTIVE To report clinical features and visual outcomes following eyelet fractures of scleral-sutured enVista MX60 (Bausch + Lomb) intraocular lenses (IOL). DESIGN Retrospective, multi-center, multi-surgeon, observational case series. METHODS Study Population: Patients with scleral-sutured enVista MX60 IOLs that experienced either an intraoperative or post-operative eyelet fracture associated with dislocation or subluxation. PROCEDURES All records were reviewed for patients with a dislocated or subluxed scleral-sutured enVista MX60 IOL. Clinical features and outcomes were gathered. Main Outcome Measures: Clinical setting, surgical technique, complications, and visual acuity. RESULTS A total of 25 scleral-sutured enVista MX60 IOLs displacements secondary to eyelet fractures in 23 eyes of 23 patients were included. There were 20 IOLs that sustained a postoperative fracture and 5 IOLs that sustained an intraoperative fracture. Of the postoperative fractures, 7 were dislocated and 13 were subluxed. Gore-Tex was the suture of choice for 19 of the postoperative fractures and all 5 of the intraoperative fractures, and Prolene was used for 1 postoperative fracture. The mean time until postoperative fracture was 96 ± 125 days, and the median time was 61 (IQR 48-144) days. Of the postoperative fractures, new MX60s were sutured in 10 patients, and 2 of them experienced repeat displacements due to a new eyelet fracture. In the intraoperative fracture group, new MX60s were sutured in 4 patients and an Akreos AO60 lens was placed in the 5th patient. The mean preoperative best-corrected logMAR visual acuity for all patients improved from 1.2 ± 0.8 (20/317 Snellen equivalent) to 0.5 ± 0.5 (20/63 Snellen equivalent) at most recent follow-up after lens replacement. CONCLUSIONS Scleral-sutured MX60 intraocular lenses can experience intraoperative or postoperative eyelet fractures, resulting in lens subluxation or dislocation. Surgeons should be aware of this complication when evaluating secondary intraocular lens options.
Collapse
|
11
|
Grzybowski A, Markeviciute A, Zemaitiene R. A narrative review of intraocular lens opacifications: update 2020. ANNALS OF TRANSLATIONAL MEDICINE 2020; 8:1547. [PMID: 33313292 PMCID: PMC7729367 DOI: 10.21037/atm-20-4207] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
The opacifications of intraocular lenses (IOLs) can significantly impact patients visual quality. Despite the identification of specific risk factors, manufacturing changes, opacifications are not eliminated. Likewise, more attention in recent studies was paid to possible new risk factors, however one of the most important purposes of the studies remains opacifications effect on visual performance, which could be disturbed in different aspects. The aim of this review is to discuss the main risk factors of IOLs opacification in particular IOL types, and its impact on vision quality. Different risk factors were discussed in the study, including the material of IOLs, the impact of the breakdown of blood-aqueous barrier (BAB), and certain surgeries that can be associated with opacification formation. Glistenings occur more often in a hydrophobic material, however, the changes in water content of the IOLs can significantly reduce the formation of glistenings. The studies showed a significant effect of intraocular injection of exogenous air or gas during Descemet-stripping endothelial keratoplasty, Descemet-stripping automated endothelial keratoplasty, Descemet membrane endothelial keratoplasty, and pars plana vitrectomy on calcification formation. It raises a concern, as the incidence of these surgeries is increasing. Visual acuity decreases significantly after the calcification in IOLs occurs, and it usually causes IOLs exchange. However, disability glare seems to be more affected in patients with IOLs, which were affected by glistenings than visual acuity. Disability glare is associated with increased levels of straylight, which was widely evaluated in recent studies and it was reported to be a susceptible measurement to detect the presence of IOLs pathology. For future researches, it should be noticed that disability glare and straylight are more appropriate in evaluating IOLs opacification effect on visual quality than visual acuity. While reviewing the main risk factors of IOLs opacifications particular attention must be paid on calcification occurrence in hydrophilic acrylic IOLs after surgeries with intraocular injection of exogenous air or gas.
Collapse
Affiliation(s)
- Andrzej Grzybowski
- Department of Ophthalmology, University of Warmia and Mazury, Olsztyn, Poland.,Institute for Research in Ophthalmology, Poznan, Poland
| | - Agne Markeviciute
- Department of Ophthalmology, Medical Academy, Lithuanian University of Health Sciences, Kaunas, Lithuania
| | - Reda Zemaitiene
- Department of Ophthalmology, Medical Academy, Lithuanian University of Health Sciences, Kaunas, Lithuania
| |
Collapse
|
12
|
Mid-term and long-term clinical assessments of a new 1-piece hydrophobic acrylic IOL with hydroxyethyl methacrylate. J Cataract Refract Surg 2020; 46:682-687. [DOI: 10.1097/j.jcrs.0000000000000142] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
13
|
Visual and refractive outcomes and glistenings occurrence after implantation of 2 hydrophobic acrylic aspheric monofocal IOLs. J Cataract Refract Surg 2020; 46:986-994. [PMID: 32271271 DOI: 10.1097/j.jcrs.0000000000000201] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE To compare the Clareon IOL with the Tecnis PCB00 IOL in terms of visual performance, refractive outcomes, glistenings occurrence, and quality-of-life outcomes. SETTING Guy's and St Thomas' NHS Foundation Trust, London, United Kingdom. DESIGN Single-center, single-masked, prospective, randomized controlled trial. METHODS One hundred thirty-nine patients with bilateral cataracts were randomized to receive the Clareon (C IOL) or Tecnis (T IOL) IOL. Visual acuity, refraction, central corneal thickness (CCT), endothelial cell loss, contrast sensitivity, mesopic gap acuity, evaluation of glistenings, and rates of perioperative and postoperative complications were recorded. Quality-of-life outcomes were measured with the EuroQOL-5 dimensions questionnaire and the patient-reported outcome measures (PROMs) questionnaire. Optimized A-constants were available for the T IOL but not for the C IOL. RESULTS Seventy-one patients (140 eyes) received the C IOLs and 68 patients (134 eyes) received the T IOLs. Data were analyzed for the first implanted eye. At 12 months, mean uncorrected distance visual acuity (logarithm of the minimum angle of resolution) was 0.02 ± 0.10 and 0.01 ± 0.08 (mean ± SD; P = .49; 95% CI, -0.02 to 0.04) in the C IOL and T IOL groups, respectively. Corrected distance visual acuity was -0.02 ± 0.09 and -0.03 ± 0.06, respectively (P = .45; 95% CI, -0.02 to 0.04). The increase in CCT was 14 ± 19 and 16 ± 28 μm, respectively (P = .63; 95% CI, -10.16 to 6.16). Mean absolute refraction spherical equivalent error from target refraction was 0.41 ± 0.28 for the C IOL and 0.25 ± 0.2 for the T IOL groups (P = .002; 95% CI, 0.08 to 0.24). Glistenings were minimal (median grade 0), with no difference in grades between groups (P = .2). PROMs improved postoperatively and were similar in both groups. CONCLUSIONS There were no differences in visual outcomes between the Clareon IOL and Tecnis PCB00 IOL. Glistenings were rarely observed in either IOL with no difference in grades. There was no difference in perioperative or postoperative complications. Surgeon optimization of the A-constant for the Clareon IOL is recommended.
Collapse
|
14
|
Pollmann AS, Lewis DR, Gupta RR. Structural integrity of intraocular lenses with eyelets in a model of transscleral fixation with the Gore-Tex suture. J Cataract Refract Surg 2020; 46:617-621. [DOI: 10.1097/j.jcrs.0000000000000129] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
15
|
Vokrojová M, Havlíčková L, Brožková M, Hlinomazová Z. Effect of Capsular Tension Ring Implantation on Postoperative Rotational Stability of a Toric Intraocular Lens. J Refract Surg 2020; 36:186-192. [DOI: 10.3928/1081597x-20200120-01] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2019] [Accepted: 01/20/2020] [Indexed: 11/20/2022]
|
16
|
Philippaki E, O'Brart DP, Hull CC. Comparison of glistenings formation and their effect on forward light scatter between the Acrysof SN60WF and Eternity Natural Uni NW-60 intraocular lenses. BMJ Open Ophthalmol 2020; 5:e000399. [PMID: 32154371 PMCID: PMC7044831 DOI: 10.1136/bmjophth-2019-000399] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2019] [Revised: 12/20/2019] [Accepted: 12/22/2019] [Indexed: 11/08/2022] Open
Abstract
Aims To compare the characteristics of glistenings and forward light scatter between the Alcon Acrysof SN60WF and Santen Eternity Natural Uni NW-60 intraocular lenses (IOLs). Methods Five Acrysof SN60WF and five Eternity Natural Uni NW-60 IOLs were studied. All IOLs were single piece blue blockers with the same dioptric power (20D) and optic diameter (6.0 mm). Glistenings were induced by a thermal accelerated ageing process. Glistenings were objectively quantified using bespoke image processing software. The angular distribution of forward light scatter was measured using an optical bench system and the straylight parameter calculated from the light scatter function. Results The median increase in the number of glistenings was 15 and 525 for the Eternity and Acrysof IOLs, respectively, which was statistically significantly different (p=0.012). Median glistenings diameter was 23.8 μm (Acrysof) and 32.8 μm (Eternity). Four (80%) of the Acrysof lenses had straylight values higher than a 20-year-old CIE standard glare observer and in two cases the straylight exceeded that of the 70-year-old CIE standard glare observer. None of the Eternity lenses had straylight values that exceeded the value for the 20-year-old CIE standard glare observer. Conclusions The Eternity Natural Uni NW-60 IOLs resisted the induction of glistenings more than the Acrysof SN60WF IOLs. Although the Acrysof IOLs developed smaller glistenings than the Eternity IOLs, there were sufficient numbers to produce a higher straylight parameter.
Collapse
|
17
|
Werner L, Thatthamla I, Ong M, Schatz H, Garcia-Gonzalez M, Gros-Otero J, Cañones-Zafra R, Teus MA. Evaluation of clarity characteristics in a new hydrophobic acrylic IOL in comparison to commercially available IOLs. J Cataract Refract Surg 2019; 45:1490-1497. [PMID: 31399323 DOI: 10.1016/j.jcrs.2019.05.017] [Citation(s) in RCA: 38] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2019] [Revised: 04/26/2019] [Accepted: 05/11/2019] [Indexed: 11/26/2022]
Abstract
PURPOSE To perform in vitro assessments of surface haze and roughness, subsurface nanoglistenings (SSNGs), and glistenings of a new hydrophobic acrylic intraocular lens (IOL) in comparison to commercially available IOLs. SETTING Universities of Utah and Alcalá, and Alcon Vision, LLC. DESIGN Experimental study. METHODS The IOLs used were Clareon CNA0T0, Tecnis ZCB00 and Tecnis OptiBlue ZCB00V, Eternity W-60, enVista MX60, and Vivinex XY1. Surface haze was assessed by the pixel intensity units (PIU) from cross-sectional slitlamp images, and it was correlated to atomic force microscopy roughness. For SSNGs, the IOLs were artificially aged up to 10 years, followed by Scheimpflug densitometry (computer-compatible tape unit [CCTU]) measurements. For glistenings, the IOLs were immersed in a water bath and subjected to temperature changes before analysis. RESULTS The surface haze (n = 10, PIU) was 4.25 ± 0.87 (SD) (CNA0T0), 9.50 ± 1.66 (ZCB00), 39.48 ± 1.97 (ZCB00V), 46.68 ± 3.16 (W-60), 44.70 ± 4.00 (MX60), and 4.42 ± 0.71 (XY1) (P < .001), which showed a strong correlation with surface roughness measurements (R = 0.94, P = .006). The densitometry (n = 10, CCTU at 10 years) was 7.30 ± 1.36 (CNA0T0), 11.88 ± 3.10 (ZCB00), 38.12 ± 2.24 (ZCB00V), 48.13 ± 9.44 (W-60), 20.20 ± 3.84 (MX60), and 6.75 ± 6.66 (XY1) (P < .001), with no significant differences between CNA0T0 vs. ZCB00 and XY1. The glistenings density (n = 30) was the lowest for the CNA0T0, W-60, and MX60 IOLs. CONCLUSIONS The new Clareon CNA0T0, which is manufactured from a hydrophobic acrylic material, exhibited among the lowest levels of surface haze and roughness, SSNGs, and glistenings compared with other commercially available hydrophobic acrylic IOLs.
Collapse
Affiliation(s)
- Liliana Werner
- John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA.
| | | | - Marcia Ong
- Alcon Vision, LLC, Fort Worth, Texas, USA
| | | | | | | | | | - Miguel A Teus
- Clinica Novovisión, Madrid, Spain; Universidad de Alcalá, Madrid, Spain
| |
Collapse
|
18
|
Łabuz G, Knebel D, Auffarth GU, Fang H, van den Berg TJ, Yildirim TM, Son HS, Khoramnia R. Glistening Formation and Light Scattering in Six Hydrophobic-Acrylic Intraocular Lenses. Am J Ophthalmol 2018; 196:112-120. [PMID: 30189220 DOI: 10.1016/j.ajo.2018.08.032] [Citation(s) in RCA: 46] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2018] [Revised: 08/16/2018] [Accepted: 08/24/2018] [Indexed: 11/28/2022]
Abstract
PURPOSE To study the glistening formation in various hydrophobic-acrylic intraocular lens (IOL) models, and to evaluate the effect of glistenings on light scattering in these IOLs. DESIGN Laboratory investigation. METHODS The susceptibility of the hydrophobic-acrylic material to develop glistenings was evaluated in 6 IOL models. Accelerated lens aging was induced by immersing the IOLs in a solution at 45 C for 24 hours and cooled to 37 C for 2.5 hours. Light microscopy and image acquisition were performed. Glistening statistics-that is, microvacuoles' (MV) number and size-were derived from image analysis. Light scattering was measured using a clinical device featuring an adaptation for in vitro IOL assessment. RESULTS The number of glistenings differed among the studied IOLs and ranged from 0 to 3532 MV/mm2. In 1 model, glistenings were found only at the periphery, with diffuse light scattering observed centrally despite the absence of microvacuoles. The mean size of glistenings ranged from 5.2 to 10.2 μm. The mean straylight parameter of the IOLs increased from 0.6 to 5.0 deg2/sr after accelerated aging. Straylight elevation demonstrated a proportional relationship with the glistening number. CONCLUSIONS We showed that hydrophobic-acrylic lenses differ in their resistance to glistenings, as one group proved to be glistening-free, but the other models revealed varying grades of glistenings. Moreover, we demonstrated that the presence of glistenings results in increased straylight, and that straylight proportionally depends on the glistenings number irrespective of the IOL model. However, more research is needed to confirm that the relationship we found holds for all hydrophobic-acrylic IOLs.
Collapse
Affiliation(s)
- Grzegorz Łabuz
- The David J. Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany
| | - Dominik Knebel
- The David J. Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany
| | - Gerd U Auffarth
- The David J. Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany.
| | - Hui Fang
- The David J. Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany
| | - Thomas Jtp van den Berg
- Netherlands Institute for Neuroscience, Royal Netherlands Academy of Arts and Sciences, Amsterdam, Netherlands
| | - Timur M Yildirim
- The David J. Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany
| | - Hyeck-Soo Son
- The David J. Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany
| | - Ramin Khoramnia
- The David J. Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany
| |
Collapse
|
19
|
In vivo evaluation of a new hydrophobic acrylic intraocular lens in the rabbit model. J Cataract Refract Surg 2018; 44:1497-1502. [PMID: 30228013 DOI: 10.1016/j.jcrs.2018.07.040] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2018] [Revised: 06/25/2018] [Accepted: 07/04/2018] [Indexed: 11/21/2022]
Abstract
PURPOSE To evaluate the uveal and capsular biocompatibility as well as positioning stability of a new hydrophobic acrylic intraocular lens (IOL) in vivo in the rabbit model and compare it with a commercially available IOL. SETTING John A Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. DESIGN Experimental study. METHODS Fifteen New Zealand rabbits had the new test IOL (Clareon CNA0T0) implanted in one eye and a control IOL (Acrysof SN60WF) implanted in the contralateral eye. The test IOL is manufactured from a new hydrophobic acrylic material incorporating ultraviolet blocker and blue light filter. Its design is based on the control IOL's platform. The rabbits were followed up with weekly slitlamp evaluations, which assessed inflammatory reactions as well as capsular bag opacification. Anterior chamber depth was measured at 1 and 4 weeks post-implantation (high-frequency ultrasound). After 4 weeks, the rabbits were killed humanely and the eyes were enucleated. The anterior segment was evaluated from the posterior or Miyake-Apple view, and was then processed for complete histopathology. RESULTS There were no statistically significant differences between test and control eyes in terms of postoperative inflammation and capsular biocompatibility, including posterior capsule opacification (P = .34, paired t test), and anterior capsule opacification (P = .53, paired t test), as observed during clinical and pathological evaluation. In vivo axial positioning for the test IOL was comparable to the control IOL and stable over time (P = .531 versus P = .788). CONCLUSIONS The new IOL showed biocompatibility and stability comparable to the control IOL.
Collapse
|
20
|
Xie YB, Ren MY, Wang Q, Wang LH. Intraocular lens optic capture in pediatric cataract surgery. Int J Ophthalmol 2018; 11:1403-1410. [PMID: 30140648 DOI: 10.18240/ijo.2018.08.24] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2018] [Accepted: 06/27/2018] [Indexed: 12/28/2022] Open
Abstract
Posterior capsule opacification (PCO) remains the most common complication of pediatric cataract surgery despite continuous efforts to reduce its incidence. For this reason, pediatric cataract surgeons have expended considerable effort into preventing and mitigating PCO. The intraocular lens (IOL) optic capture technique has been used for the prevention of PCO after pediatric cataract surgery for more than 20y, but there is still no professional consensus. However, recent research has shown encouraging results. The IOL optic capture technique can be performed without anterior vitrectomy to prevent PCO, even in younger children. The type and characteristics of IOLs used for optic capture technique, the location of IOL and the complications of IOL optic capture in children are here reviewed.
Collapse
Affiliation(s)
- Ying-Bin Xie
- Department of Ophthalmology, Shandong Provincial Hospital Affiliated to Shandong University, Jinan 250021, Shandong Province, China
| | - Mei-Yu Ren
- Department of Ophthalmology, Shandong Provincial Hospital Affiliated to Shandong University, Jinan 250021, Shandong Province, China
| | - Qi Wang
- Department of Ophthalmology, Shandong Provincial Hospital Affiliated to Shandong University, Jinan 250021, Shandong Province, China
| | - Li-Hua Wang
- Department of Ophthalmology, Shandong Provincial Hospital Affiliated to Shandong University, Jinan 250021, Shandong Province, China
| |
Collapse
|
21
|
Packer M, Williams JI, Feinerman G, Hope RS. Prospective multicenter clinical trial to evaluate the safety and effectiveness of a new glistening-free one-piece acrylic toric intraocular lens. Clin Ophthalmol 2018; 12:1031-1039. [PMID: 29910600 PMCID: PMC5987786 DOI: 10.2147/opth.s167726] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Purpose Glistening formation in the intraocular lens (IOL) optic has the potential to impact quality of vision. The enVista One-Piece Hydrophobic Acrylic Spherical IOL Model MX60 (MX60 IOL) is currently the only US Food and Drug Administration-approved IOL with a label of “no glistenings”. The purpose of this prospective, multicenter, partially randomized, partially controlled, double-masked, pivotal study was to evaluate the safety and effectiveness of the enVista One-Piece Hydrophobic Acrylic MX60T Toric IOL (enVista MX60T Toric IOL). Patients and methods Subjects (n=191) were implanted with the enVista MX60T Toric IOL (cylinder powers 1.25, 2.00, or 2.75 D) or the parent MX60 IOL (control). Eyes within the lowest range of corneal astigmatism were randomized to receive either Toric 1.25 D IOL or control IOL in a 1:1 ratio. All subjects with corneal astigmatism requiring 2.00 or 2.75 D cylinder IOLs received toric IOLs. Rotational stability, cylinder reduction, and best-corrected distance visual acuity were primary effectiveness endpoints measured at Visit 4 (120–180 days postoperatively). Results Visit 4 mean absolute axis misalignment in the All Toric group was 4.68°±7.33°, and all subjects had ≤5° absolute rotation from Visit 3 to Visit 4. The 1.25 D group had significantly greater improvement in dioptric cylinder reduction (P<0.001), percent cylinder reduction (P<0.001), and mean uncorrected distance visual acuity (P<0.001), compared to control at Visit 4. Most adverse events (AEs) were mild, with no serious AEs in the study eyes. The rates of cumulative AEs through Visit 4 were below International Organization for Standardization (ISO) standard 11979-7 AE rates. Conclusion enVista MX60T Toric IOL is safe and effective for patients with preoperative corneal astigmatism undergoing IOL implantation.
Collapse
Affiliation(s)
- Mark Packer
- Mark Packer MD Consulting, Inc., Boulder, CO, USA
| | - Jon I Williams
- Surgical Clinical and Medical Affairs, Bausch & Lomb Inc., Irvine, CA, USA
| | | | - Richard S Hope
- Surgical Clinical and Medical Affairs, Bausch & Lomb Inc., Irvine, CA, USA
| |
Collapse
|
22
|
Lee GY, Kim IG, Yu S, Lee GJ, Lee KW, Park YJ. Intraindividual Comparison of Visual Outcomes between Blue Light-filtering and Ultraviolet Light-filtering Intraocular Lens. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY 2017. [DOI: 10.3341/jkos.2017.58.1.34] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
| | | | - Sung Yu
- Cheil Eye Hospital, Daegu, Korea
| | | | | | | |
Collapse
|
23
|
Abstract
PURPOSE OF REVIEW This review outlines concepts in intraocular lens (IOL) optics and aberrations important both for current IOLs and for new IOLs in development. RECENT FINDINGS Optical aberrations make a significant impact on the laboratory and clinical performance of IOLs, especially under mesopic and low-contrast conditions. Minimizing or correcting these aberrations can potentially improve visual function. Strategic management of aberrations can have clinical utility for extended depth of focus and presbyopia correction. SUMMARY All IOLs affect ocular aberrations in some manner. It is important for clinicians and researchers to understand the implications how any residual aberrations could affect visual quality, visual side-effects, and depth of focus.
Collapse
|
24
|
Tortolano L, Hammami S, Manerlax K, Do B, Yagoubi N. RP-HPLC detection and dosage method for acrylic monomers and degradation products released from implanted medical devices. J Chromatogr B Analyt Technol Biomed Life Sci 2016; 1038:26-33. [PMID: 27776330 DOI: 10.1016/j.jchromb.2016.10.020] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2016] [Revised: 10/15/2016] [Accepted: 10/17/2016] [Indexed: 10/20/2022]
Abstract
Acrylic copolymers are useful in medical therapeutics. As in dental implants or intraocular lenses, acrylics are present in many medical devices or drug adjuvants. Industrial using of acrylics is still important in painting or textile manufacturing. Scientific research background has proved that acrylic suffer for depolymerized and cross-linking mechanisms under heating and photo-oxidative conditions. Those aging processes could lead to release of unreacted monomers and degradation products. We developed a new RP-HPLC method with good resolution, recovery, linearity, detection and quantification limits that is efficient for acrylic monomers quantification in in vitro and in vivo saline solution matrices. This method allows the detection of copolymer and medical devices degradation products too. Both the limit of quantification and the limit of detection for monomers and degradation products are above cytotoxic concentrations for human epithelial cells. Those biological results confirm the interest of the method for dosage of unreacted acrylics after polymerization and for the research of degradation products in body fluids as aqueous humor.
Collapse
Affiliation(s)
- Lionel Tortolano
- EA 401: Matériaux et santé, Université Paris-Saclay, UFR Pharmacie, Châtenay-Malabry F-92290, France; Gustave Roussy, Université Paris-Saclay, Département de Pharmacie Clinique, Villejuif F-94805, France.
| | - Senda Hammami
- EA 401: Matériaux et santé, Université Paris-Saclay, UFR Pharmacie, Châtenay-Malabry F-92290, France
| | - Katia Manerlax
- EA 401: Matériaux et santé, Université Paris-Saclay, UFR Pharmacie, Châtenay-Malabry F-92290, France
| | - Bernard Do
- EA 401: Matériaux et santé, Université Paris-Saclay, UFR Pharmacie, Châtenay-Malabry F-92290, France; Hôpital Universitaire Henri Mondor, AP-HP, Département de Pharmacie, Créteil F-94010, France
| | - Najet Yagoubi
- EA 401: Matériaux et santé, Université Paris-Saclay, UFR Pharmacie, Châtenay-Malabry F-92290, France
| |
Collapse
|
25
|
|
26
|
Magin CM, May RM, Drinker MC, Cuevas KH, Brennan AB, Reddy ST. Micropatterned Protective Membranes Inhibit Lens Epithelial Cell Migration in Posterior Capsule Opacification Model. Transl Vis Sci Technol 2015; 4:9. [PMID: 25883876 DOI: 10.1167/tvst.4.2.9] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2014] [Accepted: 02/04/2015] [Indexed: 12/15/2022] Open
Abstract
PURPOSE To evaluate the ability of Sharklet (SK) micropatterns to inhibit lens epithelial cell (LEC) migration. Sharklet Technologies, Inc. (STI) and InSight Innovations, LLC have proposed to develop a Sharklet-patterned protective membrane (PM) to be implanted in combination with a posterior chamber intraocular lens (IOL) to inhibit cellular migration across the posterior capsule, and thereby reduce rates of posterior capsular opacification (PCO). METHODS A variety of STI micropatterns were evaluated versus smooth (SM) controls in a modified scratch wound assay for the ability to reduce or inhibit LEC migration. The best performing topography was selected, translated to a radial design, and applied to PM prototypes. The PM prototypes were tested in an in vitro PCO model for reduction of cell migration behind an IOL versus unpatterned prototypes and IOLs with no PM. In both assays, cell migration was analyzed with fluorescent microscopy. RESULTS All SK micropatterns significantly reduced LEC migration compared with SM controls. Micropatterns that protruded from the surface reduced migration more than recessed features. The best performing micropattern reduced LEC coverage by 80%, P = 0.0001 (ANOVA, Tukey Test). Micropatterned PMs reduced LEC migration in a PCO model by 50%, P = 0.0005 (ANOVA, Tukey Test) compared with both IOLs with no PM and IOLs with SM PMs. CONCLUSIONS Collectively, in vitro results indicate the implantation of micropatterned PMs in combination with posterior chamber IOLs could significantly reduce rates of clinically relevant PCO. This innovative technology is a globally accessible solution to high PCO rates. TRANSLATIONAL RELEVANCE A novel IOL incorporating the SK micropattern in a membrane design surrounding the optic may help increase the success of cataract surgery by reducing secondary cataract, or PCO.
Collapse
Affiliation(s)
| | - Rhea M May
- Sharklet Technologies, Inc., Aurora, CO, USA
| | | | - Kevin H Cuevas
- Rocky Mountain Ophthalmology and InSight Innovations, LLC, Golden, CO, USA
| | - Anthony B Brennan
- Sharklet Technologies, Inc., Aurora, CO, USA ; Department of Materials Science & Engineering and J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL, USA
| | | |
Collapse
|
27
|
Tetz M, Jorgensen MR. New Hydrophobic IOL Materials and Understanding the Science of Glistenings. Curr Eye Res 2015; 40:969-81. [DOI: 10.3109/02713683.2014.978476] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|