1
|
Ahmar Siddiqui M, Kumar Biswal B, Siriweera B, Chen G, Wu D. Integrated self-forming dynamic membrane (SFDM) and membrane-aerated biofilm reactor (MABR) system enhanced single-stage autotrophic nitrogen removal. BIORESOURCE TECHNOLOGY 2022; 345:126554. [PMID: 34906703 DOI: 10.1016/j.biortech.2021.126554] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/26/2021] [Revised: 12/06/2021] [Accepted: 12/08/2021] [Indexed: 06/14/2023]
Abstract
The membrane aerated biofilm reactor (MABR) is a novel bioreactor technology, facilitating single-stage autotrophic nitrogen removal. Two laboratory-scale MABRs equipped with non-woven fabrics were operated simultaneously without and with a self-forming dynamic membrane (SFDM) filtration module. After 87 days of operation (system start-up), the reactor incorporated with SFDM filtration showed better performance in terms of total nitrogen removal (>80%) and effluent suspended solid (less than1 mg/L) than the MABR in the up flow anaerobic sludge blanket (UASB) configuration (i.e., without SFDM). The incorporation of SFDM has the ability to retain more slow growing biomass (anammox) inside the reactor. Microbial characterization by 16S rRNA-based amplicon sequencing shows that the abundance and composition of microbial communities in two MABR systems were different, i.e., the genusRhodanobacterwas abundant in UASB-MABR, while Calorithrixwas dominant in SFDM-MABR. PCA-based statistical analysis demonstrated a positive association between reactor performance, membrane characteristics and microbial communities.
Collapse
Affiliation(s)
- Muhammad Ahmar Siddiqui
- Department of Civil and Environmental Engineering, Water Technology Center, Hong Kong Branch of Chinese National Engineering Research Centre for Control & Treatment of Heavy Metal Pollution, The Hong Kong University of Science & Technology, Clear Water Bay, Kowloon, Hong Kong, PR China
| | - Basanta Kumar Biswal
- Department of Civil and Environmental Engineering, Water Technology Center, Hong Kong Branch of Chinese National Engineering Research Centre for Control & Treatment of Heavy Metal Pollution, The Hong Kong University of Science & Technology, Clear Water Bay, Kowloon, Hong Kong, PR China
| | - Buddhima Siriweera
- Department of Civil and Environmental Engineering, Water Technology Center, Hong Kong Branch of Chinese National Engineering Research Centre for Control & Treatment of Heavy Metal Pollution, The Hong Kong University of Science & Technology, Clear Water Bay, Kowloon, Hong Kong, PR China
| | - Guanghao Chen
- Department of Civil and Environmental Engineering, Water Technology Center, Hong Kong Branch of Chinese National Engineering Research Centre for Control & Treatment of Heavy Metal Pollution, The Hong Kong University of Science & Technology, Clear Water Bay, Kowloon, Hong Kong, PR China
| | - Di Wu
- Department of Civil and Environmental Engineering, Water Technology Center, Hong Kong Branch of Chinese National Engineering Research Centre for Control & Treatment of Heavy Metal Pollution, The Hong Kong University of Science & Technology, Clear Water Bay, Kowloon, Hong Kong, PR China; Center for Environment and Energy Research, Ghent University Global Campus, Incheon, Republic of Korea; Department of Green Chemistry and Technology, Ghent University, Ghent, Belgium.
| |
Collapse
|
2
|
Díez-Montero R, Castrillo M, Casao M, Tejero I. Model-based evaluation of a trickling filter facility upgrade to biological nutrient removal. THE SCIENCE OF THE TOTAL ENVIRONMENT 2019; 661:187-195. [PMID: 30669051 DOI: 10.1016/j.scitotenv.2019.01.136] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/18/2018] [Revised: 01/11/2019] [Accepted: 01/12/2019] [Indexed: 05/26/2023]
Abstract
This article presents the feasibility evaluation and preliminary design of a wastewater treatment plant upgrade supported by simulation. The existing facility was based on trickling filters, and the objective of the upgrade was to achieve nutrients removal. The proposed solution modifies the existing primary clarifier to host an anaerobic-anoxic suspended growth reactor, which is an alternative that, to our knowledge, has not been proposed or explored so far. The trickling filters would remain as aerobic reactors. In this study, the novel treatment scheme has been assessed for the first time, through model simulations. The modified treatment train was simulated, showing that the anoxic zone is able to denitrify satisfactorily achieving the required effluent nitrogen concentration. However, to promote biological phosphorus removal, an additional aerobic zone combined with a bypass of activated sludge from the anoxic zone to the first trickling filter is needed, in order to provide aerobic conditions to the phosphate accumulating organisms. Several combinations of additional aerobic volume and sludge bypass flowrate were found to successfully achieve both nitrogen and phosphorus removal, using the existing facilities without the need for new reactors neither implementing modifications that could put the trickling filters' physical integrity at risk. The novel treatment scheme could be applied in other cases with similar flowsheet in the same context.
Collapse
Affiliation(s)
- Rubén Díez-Montero
- Department of Water and Environmental Sciences and Technologies, University of Cantabria, ETS Ingenieros de Caminos, Canales y Puertos, Avda. Los Castros s/n, 39005 Santander, Spain; Department of Civil and Environmental Engineering, Universitat Politècnica de Catalunya, c/ Jordi Girona 1-3, Building D1, E-08034 Barcelona, Spain.
| | - María Castrillo
- Department of Water and Environmental Sciences and Technologies, University of Cantabria, ETS Ingenieros de Caminos, Canales y Puertos, Avda. Los Castros s/n, 39005 Santander, Spain
| | - Marta Casao
- FCC Aqualia, FCC Servicios Ciudadanos, c/ Federico Salmón 13 Planta 2, 28016 Madrid, Spain
| | - Iñaki Tejero
- Department of Water and Environmental Sciences and Technologies, University of Cantabria, ETS Ingenieros de Caminos, Canales y Puertos, Avda. Los Castros s/n, 39005 Santander, Spain
| |
Collapse
|