1
|
Wang AWT, Stockton DJ, Flury A, Kim TG, Roffey DM, Lefaivre KA. Radiographic Union Assessment in Surgically Treated Distal Femur Fractures: A Systematic Review. JBJS Rev 2024; 12:01874474-202403000-00001. [PMID: 38446912 DOI: 10.2106/jbjs.rvw.23.00223] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/08/2024]
Abstract
BACKGROUND Distal femur fractures are known to have challenging nonunion rates. Despite various available treatment methods aimed to improve union, optimal interventions are yet to be determined. Importantly, there remains no standard agreement on what defines radiographic union. Although various proposed criteria of defining radiographic union exist in the literature, there is no clear consensus on which criteria provide the most precise measurement. The use of inconsistent measures of fracture healing between studies can be problematic and limits their generalizability. Therefore, this systematic review aims to identify how fracture union is defined based on radiographic parameters for surgically treated distal femur fractures in current literature. METHODS In accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, Medline, EMBASE, Cochrane Central Register of Controlled Trials, and Web of Science Core Collection databases were searched from inception to October 2022. Studies that addressed surgically treated distal femur fractures with reported radiographic union assessment were included. Outcomes extracted included radiographic definition of union; any testing of validity, reliability, or responsiveness; reported union rate; reported time to fracture union; and any functional outcomes correlated with radiographic union. RESULTS Sixty articles with 3,050 operatively treated distal femur fractures were included. Operative interventions included lateral locked plate (42 studies), intramedullary nail (15 studies), dynamic condylar screw or blade plate (7 studies), dual plate or plate and nail construct (5 studies), distal anterior-posterior/posterior-anterior screws (1 study), and external fixation with a circular frame (1 study). The range of mean follow-up time reported was 4.3 to 44 months. The most common definitions of fracture union included "bridging or callus formation across 3 of 4 cortices" in 26 (43%) studies, "bony bridging of cortices" in 21 (35%) studies, and "complete bridging of cortices" in 9 (15%) studies. Two studies included additional assessment of radiographic union using the Radiographic Union Scale in Tibial fracture (RUST) or modified Radiographic Union Scale in Tibial fracture (mRUST) scores. One study included description of validity, and the other study included reliability testing. The reported mean union rate of distal femur fractures was 89% (range 58%-100%). The mean time to fracture union was documented in 49 studies and found to be 18 weeks (range 12-36 weeks) in 2,441 cases. No studies reported correlations between functional outcomes and radiographic parameters. CONCLUSION The current literature evaluating surgically treated distal femur fractures lacks consistent definition of radiographic fracture union, and the appropriate time point to make this judgement is unclear. To advance surgical optimization, it is necessary that future research uses validated, reliable, and continuous measures of radiographic bone healing and correlation with functional outcomes. LEVEL OF EVIDENCE Level IV. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Alice Wei Ting Wang
- Department of Orthopaedics, Faculty of Medicine, University of British Columbia, Vancouver, British Columbia, Canada
| | - David J Stockton
- Department of Orthopaedics, Faculty of Medicine, University of British Columbia, Vancouver, British Columbia, Canada
- Division of Orthopaedic Trauma, Vancouver General Hospital, Vancouver Coastal Health, Vancouver, British Columbia, Canada
| | - Andreas Flury
- Department of Orthopaedics, Faculty of Medicine, University of British Columbia, Vancouver, British Columbia, Canada
| | - Taylor G Kim
- Division of Orthopaedic Trauma, Vancouver General Hospital, Vancouver Coastal Health, Vancouver, British Columbia, Canada
| | - Darren M Roffey
- Department of Orthopaedics, Faculty of Medicine, University of British Columbia, Vancouver, British Columbia, Canada
- Division of Orthopaedic Trauma, Vancouver General Hospital, Vancouver Coastal Health, Vancouver, British Columbia, Canada
| | - Kelly A Lefaivre
- Department of Orthopaedics, Faculty of Medicine, University of British Columbia, Vancouver, British Columbia, Canada
- Division of Orthopaedic Trauma, Vancouver General Hospital, Vancouver Coastal Health, Vancouver, British Columbia, Canada
| |
Collapse
|
2
|
Zdero R, Gide K, Brzozowski P, Schemitsch EH, Bagheri ZS. Biomechanical design optimization of distal femur locked plates: A review. Proc Inst Mech Eng H 2023; 237:791-805. [PMID: 37366552 DOI: 10.1177/09544119231181487] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/28/2023]
Abstract
Clinical findings, manufacturer instructions, and surgeon's preferences often dictate the implantation of distal femur locked plates (DFLPs), but healing problems and implant failures still persist. Also, most biomechanical researchers compare a particular DFLP configuration to implants like plates and nails. However, this begs the question: Is this specific DFLP configuration biomechanically optimal to encourage early callus formation, reduce bone and implant failure, and minimize bone "stress shielding"? Consequently, it is crucial to optimize, or characterize, the biomechanical performance (stiffness, strength, fracture micro-motion, bone stress, plate stress) of DFLPs influenced by plate variables (geometry, position, material) and screw variables (distribution, size, number, angle, material). Thus, this article reviews 20 years of biomechanical design optimization studies on DFLPs. As such, Google Scholar and PubMed websites were searched for articles in English published since 2000 using the terms "distal femur plates" or "supracondylar femur plates" plus "biomechanics/biomechanical" and "locked/locking," followed by searching article reference lists. Key numerical outcomes and common trends were identified, such as: (a) plate cross-sectional area moment of inertia can be enlarged to lower plate stress at the fracture; (b) plate material has a larger influence on plate stress than plate thickness, buttress screws, and inserts for empty plate holes; (c) screw distribution has a major influence on fracture micro-motion, etc. Recommendations for future work and clinical implications are then provided, such as: (a) simultaneously optimizing fracture micro-motion for early healing, reducing bone and implant stresses to prevent re-injury, lowering "stress shielding" to avoid bone resorption, and ensuring adequate fatigue life; (b) examining alternate non-metallic materials for plates and screws; (c) assessing the influence of condylar screw number, distribution, and angulation, etc. This information can benefit biomedical engineers in designing or evaluating DFLPs, as well as orthopedic surgeons in choosing the best DFLPs for their patients.
Collapse
Affiliation(s)
- Radovan Zdero
- Orthopaedic Biomechanics Lab, Victoria Hospital, London, ON, Canada
| | - Kunal Gide
- Department of Mechanical Engineering, George Mason University, Fairfax, VA, USA
| | - Pawel Brzozowski
- Orthopaedic Biomechanics Lab, Victoria Hospital, London, ON, Canada
| | - Emil H Schemitsch
- Orthopaedic Biomechanics Lab, Victoria Hospital, London, ON, Canada
- Division of Orthopaedic Surgery, Western University, London, ON, Canada
| | - Z Shaghayegh Bagheri
- Department of Mechanical Engineering, George Mason University, Fairfax, VA, USA
- Kite Research Institute, Toronto Rehab Institute, University Health Network, Toronto, ON, Canada
| |
Collapse
|
3
|
Analysis of 101 Mechanical Failures in Distal Femur Fractures Treated with 3 Generations of Precontoured Locking Plates. J Orthop Trauma 2023; 37:8-13. [PMID: 35862769 DOI: 10.1097/bot.0000000000002460] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 07/12/2022] [Indexed: 02/02/2023]
Abstract
OBJECTIVES To evaluate mechanical treatment failure in a large patient cohort sustaining a distal femur fracture treated with a distal femoral locking plate (DFLP). DESIGN This retrospective case-control series evaluated mechanical treatment failures of DFLPs. SETTING The study was conducted at 8 Level I trauma centers from 2010 to 2017. PATIENTS AND PARTICIPANTS One hundred one patients sustaining OTA/AO 33-A and C distal femur fractures were treated with DFLPs that experienced mechanical failure. INTERVENTION The intervention included the treatment of a distal femur fracture with a DFLP, affected by mechanical failure (implant failure by loosening or breakage). MAIN OUTCOME MEASURE The main outcome measures included injury and DFLP details; modes and timing of failure were studied. RESULTS One hundred forty-six nonunions were found overall (13.4%) including 101 mechanical failures (9.3%). Failures occurred in different manners, locations, and times depending on the DFLPs. For example, 33 of 101 stainless steel (SS) plates (33%) failed by bending or breaking in the working length, whereas no Ti plates failed here ( P < 0.05). Eleven of 12 failures with titanium-Less Invasive Stabilization System (92%) occurred by lost shaft fixation, mostly by the loosening of unicortical screws (91%). Sixteen of 44 variable -angled-LCP failures (36%) occurred at the distal plate-screw junction, whereas only 5 of 61 other DFLPs (8%) failed this way ( P < 0.05). Distal failures occurred on average at 23.7 weeks compared with others that occurred at 38.4 weeks ( P < 0.05). Variable -angled-LCP distal screw-plate junction failures occurred earlier (mean 21.4 weeks). CONCLUSION Nonunion and mechanical failure occurred in 14% and 9% of patients, respectively, in this large series of distal femur fracture treated with a DFLP. The mode, location, presence of a prosthesis, and timing of failure varied depending on the characteristics of DFLP. This information should be used to optimize implant usage and design to prolong the period of stable fixation before potential implant failures occur in patients with a prolonged time to union. LEVEL OF EVIDENCE Economic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Collapse
|
4
|
Total femur fixation using the "nail-plate docking technique" for ipsilateral femur shaft fracture. Trauma Case Rep 2022; 42:100722. [PMID: 36281428 PMCID: PMC9587334 DOI: 10.1016/j.tcr.2022.100722] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/16/2022] [Indexed: 11/09/2022] Open
Abstract
In an aging society, the number of femoral fractures is increasing, as well as the incidence of periprosthetic fractures. These secondary fractures are often difficult to fixate stably because of the osteoporotic bone and the existence of the former implant. Herein, we present two cases of secondary femoral shaft fractures after osteosyntheses for distal femur fractures with polyaxial locking plates (Non-Contact-Bridging Distal Femur, NCB-DF®, ZimmerBIOMET, Winterthur, Switzerland). Antegrade intramedullary nails (Natural Nail®-GT Femoral, ZimmerBIOMET, Winterthur, Switzerland) were utilized without removal of the NCB-DFs. In these osteosyntheses, proximal locking screws of NCB-DFs were inserted and locked into the distal inter-locking holes of Natural Nails. This "nail-plate docking technique" could allow for more stable fixation of the whole femur with minimally invasive surgical intervention while preserving the existing implant. Although there are a few surgical technical knacks and pitfalls in inserting the screw, further fractures of the femur could also be prevented with this technique.
Collapse
|
5
|
de Ruijter M, Lucke J, Yuan J, Derksen R. Patient experience from a doctor's perspective: A case report concerning treatment, fracture healing and rehabilitation of multiple complex injuries due to a high energy motor vehicle collision. Trauma Case Rep 2022; 42:100699. [PMID: 36210916 PMCID: PMC9535306 DOI: 10.1016/j.tcr.2022.100699] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/02/2022] [Indexed: 11/24/2022] Open
Abstract
A 35-year old healthy male trauma surgery chief resident, suffered a high-speed motor vehicle collision. The patient sustained the following injuries: a Gustilo-Anderson grade 2 open comminuted intra-articular fracture of the left distal femur (AO 33C3.3), a Hawkins 1A neck fracture of the right talus (AO 81.2A), an undisplaced Lisfranc injury of the right foot comprising avulsion fractures at the base of the 1st, 2nd and 5th metatarsal as well as the cuboid bone suggesting ligament injury and 2nd to 5th carpometacarpal dislocations of the right (non-dominant) hand with comminuted fractures of the capitate, hamate, trapezoid and the base of the fifth metacarpal bone. A staged-treatment approach ensued. An external fixator (ex-fix) was placed over the left knee, followed by definitive fixation of the distal femoral fracture using a Qwix screw, Non-Contact Bridging (NCB) plate and Locking Compression Plate (LCP). An ex-fix was placed over the right wrist, followed by open reduction and k-wire fixation. The talar fracture of the right foot was treated with a single lag screw and the Lisfranc injury was treated non-operatively with four weeks of non-weight bearing cast immobilization. An intensive clinical rehabilitation program was started, including early use of Continuous Passive Motion (CPM), daily non-weightbearing swimming pool exercises, hand, physical and recreational therapy. One year after the injury the patient was rehabilitated and resumed his surgical residency. Two years after the injury, limited flexion and pain in the left leg remains, possibly related to partial union of the femoral fracture. Range of motion (ROM) of the right ankle and wrist remains limited, not causing significant functional impairment. Lessons learned from a patient experience combined with detailed descriptions of injuries, rehabilitation and long term outcomes can be used as a reference for treating patients with comparable injuries.
Collapse
Affiliation(s)
- M.A. de Ruijter
- Department of Traumasurgery, Zaandam Medical Centre, Zaandam, the Netherlands,Corresponding author at: Department of Traumasurgery, Zaandam Medical Centre, Koningin Julianaplein 58, 1502 DV Zaandam, the Netherlands.
| | - J.A. Lucke
- Department of Emergency Medicine, Spaarne Gasthuis, Haarlem, the Netherlands
| | - J.Z. Yuan
- Department of Traumasurgery, Zaandam Medical Centre, Zaandam, the Netherlands
| | - R.J. Derksen
- Department of Traumasurgery, Zaandam Medical Centre, Zaandam, the Netherlands
| |
Collapse
|
6
|
Jankowski JM, Szukics PF, Shah JK, Keller DM, Pires RE, Liporace FA, Yoon RS. Comparing Intramedullary Nailing Versus Locked Plating in the Treatment of Native Distal Femur Fractures: Is One Superior to the Other?. Indian J Orthop 2021; 55:646-654. [PMID: 33995868 PMCID: PMC8081772 DOI: 10.1007/s43465-020-00331-z] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/25/2020] [Accepted: 12/12/2020] [Indexed: 02/04/2023]
Abstract
INTRODUCTION Distal femur fractures make up < 1% of all fractures and 3-6% of all femur fractures. In the literature, both intramedullary nailing (IMN) and locked plating (LP) have shown favorable results, but there is no consensus on a gold standard. The purpose of this systematic review is to compare outcomes of native distal femur fractures treated via IMN versus LP in an effort to determine if one is superior to the other. METHODS Systematic review of MEDLINE, EMBASE, and Cochrane Library databases was conducted according to PRISMA guidelines. Only articles published within the last ten years were included. Evidence and study quality were evaluated with the MQOE and Oxford Criteria. RESULTS Forty-six articles were included in the review. Fractures treated with IMN were found to have a 93.9% union rate, an average time to union of 19.2 weeks, an average arc of motion of 105.1 degrees, with an average of 14.4 degrees of malalignment. Fractures treated with LP were found to have a 90.2% union rate, an average time to union of 20.5 weeks, an average arc of motion of 104 degrees, with an average of 12.6 degrees of malalignment. CONCLUSION Compiled data comparisons revealed no differences in union rate, malalignment, time to union, average arc of motion, or complication rates requiring a return to the operating room. Until higher level randomized data is available, either IMN or LP are acceptable methods of treatment for native distal femur fractures.
Collapse
Affiliation(s)
- Jaclyn M. Jankowski
- Division of Orthopaedic Trauma, Department of Orthopaedic Surgery, Jersey City Medical Center-RWJBarnabas Health, 377 Jersey Ave, Suite 280A, Jersey City, NJ 07302 USA
| | - Patrick F. Szukics
- Division of Orthopaedic Trauma, Department of Orthopaedic Surgery, Jersey City Medical Center-RWJBarnabas Health, 377 Jersey Ave, Suite 280A, Jersey City, NJ 07302 USA
| | - Jay K. Shah
- Division of Orthopaedic Trauma, Department of Orthopaedic Surgery, Jersey City Medical Center-RWJBarnabas Health, 377 Jersey Ave, Suite 280A, Jersey City, NJ 07302 USA
| | - David M. Keller
- Division of Orthopaedic Trauma, Department of Orthopaedic Surgery, Jersey City Medical Center-RWJBarnabas Health, 377 Jersey Ave, Suite 280A, Jersey City, NJ 07302 USA
| | - Robinson E. Pires
- Division of Orthopaedic Trauma, Department of Orthopaedic Surgery, Felicio Rocho Hospital, Federal University of Minas Gerais, Belo Horizonte, MG Brazil
| | - Frank A. Liporace
- Division of Orthopaedic Trauma, Department of Orthopaedic Surgery, Jersey City Medical Center-RWJBarnabas Health, 377 Jersey Ave, Suite 280A, Jersey City, NJ 07302 USA
| | - Richard S. Yoon
- Division of Orthopaedic Trauma, Department of Orthopaedic Surgery, Jersey City Medical Center-RWJBarnabas Health, 377 Jersey Ave, Suite 280A, Jersey City, NJ 07302 USA
| |
Collapse
|
7
|
Turhan S, Görgülü Ö. Is the compressive nail method capable of accelerating bone union in patients with femoral distal diaphysis fracture? Orthop Traumatol Surg Res 2021; 107:102786. [PMID: 33333271 DOI: 10.1016/j.otsr.2020.102786] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/03/2019] [Revised: 08/28/2020] [Accepted: 10/20/2020] [Indexed: 02/03/2023]
Abstract
OBJECTIVES This study was conducted to evaluate clinically and radiologically the patients for whom compressive and non-compressive intramedullary nails were applied and to analyse the compression effectiveness in adult femur distal diaphysis fractures. HYPOTHESIS The compressive locked nails shortened the union period in the distal diaphysis fractures, and it was found to be an effective method, as the pseudoarthrosis rate was lower. MATERIAL AND METHODS A retrospective study was conducted among 59 patients for whom the compressive and non-compressive IMNs were applied to treat femur distal diaphysis fractures. Thirty-one for whom the non-compressive IMN was applied were categorised as group I, and 28 for whom the compressive nail was applied were categorised as group II. Finite element analysis was performed using 1.5mm compression, and a mean stress value of 34.67Mpa. RESULTS The mean values of union period were calculated as 13.6±2.4 weeks (range: 11-20 months) and functional score was 79.2, respectively in group I, and they were evaluated as a good grade. In group II, the respective mean values of union period were 11.5±2.6 weeks (range: 10-17 months) and functional score was 86, and they were evaluated as excellent. CONCLUSION Radiological and functional scores were determined to be better with interlocking compressive nails and shortened the fracture union period in the follow-up in adult femur distal diaphysis fractures. LEVEL OF EVIDENCE III; retrospective cohort study.
Collapse
Affiliation(s)
- Sadullah Turhan
- Department of Orthopedics and Traumatology, Antalya Training and Research Hospital, Antalya, Turkey.
| | - Özkan Görgülü
- Department of Anesthesiology and Reanimation, Antalya Training and Research Hospital, Antalya, Turkey
| |
Collapse
|
8
|
Yoon BH, Park IK, Kim Y, Oh HK, Choo SK, Sung YB. Incidence of nonunion after surgery of distal femoral fractures using contemporary fixation device: a meta-analysis. Arch Orthop Trauma Surg 2021; 141:225-233. [PMID: 32388648 DOI: 10.1007/s00402-020-03463-x] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/18/2019] [Indexed: 12/12/2022]
Abstract
PURPOSE Nonunion is the most frequent cause of reoperation and is associated with high morbidity after distal femur fracture (DFF). We examined the rates of nonunion requiring reoperation after fixation for DFF using a locking compression plate (LCP) or retrograde intramedullary nail (RIMN). METHODS We included four studies comparing LCP and RIMN and 38 single-cohort studies reporting LCP or RIMN. In total, 2156 femurs were included and 166 non-unions were detected. We conducted a pair-wise meta-analysis (with a fixed-effects model) on the four comparative studies and a proportional meta-analysis on the 38 articles to estimate the nonunion rate. We performed sensitivity analysis by comparing studies using LCP with less invasive surgical systems (LISS) with those that used RIMN. RESULTS The pairwise meta-analysis showed a similar nonunion rate between the groups [odds ratio: 1.02; 95% confidence interval (CI) 0.94-1.11, p = 0.633]. According to proportional meta-analysis, the pooled prevalence of nonunion was 5% (95% CI 4-7) totally, 6% (95% CI 4-8) in the LCP group, and 4% (95% CI 2-6) in the RIMN group (heterogeneity: p = 0.105). According to the sensitivity analysis, there was no difference in the union rate. The pooled prevalence of nonunion from sensitivity analysis was 4 % (95% CI, 3-5); it was 4% (95% CI, 3-6) in LCP with LISS and was 4% (95% CI, 2-6) in RIMN group (heterogeneity: p = 0.941). CONCLUSION Approximately 5% of patients who underwent LCP or RIMN fixation developed nonunion. Therefore, LCP and RIMN are effective DFF techniques and mastering one of them is essential.
Collapse
Affiliation(s)
- Byung-Ho Yoon
- Department of Orthopaedic Surgery, Inje University College of Medicine, Seoul Paik Hospital, Seoul, South Korea
| | - In Keun Park
- Department of Orthopaedic Surgery, Inje University College of Medicine, Seoul Paik Hospital, Seoul, South Korea
| | - Youngwoo Kim
- Department of Orthopedic Surgery, Uijeongbu St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, South Korea
| | - Hyoung-Keun Oh
- Department of Orthopedic Surgery, Ilsan Paik Hospital, Inje University College of Medicine, Goyang, South Korea
| | - Suk Kyu Choo
- Department of Orthopedic Surgery, Ilsan Paik Hospital, Inje University College of Medicine, Goyang, South Korea
| | - Yerl-Bo Sung
- Department of Orthopaedic Surgery, Inje University College of Medicine, Sanggye Paik Hospital, Seoul, South Korea.
| |
Collapse
|
9
|
Campana V, Ciolli G, Cazzato G, Giovannetti De Sanctis E, Vitiello C, Leone A, Liuzza F, Maccauro G. Treatment of distal femur fractures with VA-LCP condylar plate: A single trauma centre experience. Injury 2020; 51 Suppl 3:S39-S44. [PMID: 31703959 DOI: 10.1016/j.injury.2019.10.078] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/22/2019] [Revised: 09/18/2019] [Accepted: 10/22/2019] [Indexed: 02/02/2023]
Abstract
INTRODUCTION Given the recent criticisms in the literature regarding Synthes Variable Angle Locking Compression Condylar Plate (VA-LCP), the purpose of this study was to evaluate functional outcome, fracture healing, and complications of distal femoral intra-articular fractures using this device. METHODS Patients with distal femoral fractures treated with 4.5 mm VA-LCP Curved Condylar Plate were included in this retrospective study. Follow-ups were at 4 weeks, 3 months, 6 months and 1 year. For the clinical and functional assessment of the knee, WOMAC, Koos Knee Survey, the Knee Score Society and the SF-12 questionnaire were used. Radiographically we assessed the fracture healing and the angles of the operated limb compared to the healthy contralateral limb. Complications have also been described. RESULTS Forty-two patients with distal femoral fractures were included in the study. The mean follow-up was 8 months. Most cases (57%) reported a type 33-A fracture. Radiological healing was achieved in 33 cases; the mean time required to heal was 13 weeks. Three patients had an early postoperative complication and four cases had a late complication. Five cases required additional surgical procedures. Most patients (47.2%) achieved a complete flexion of 130° or more. WOMAC mean value 27.4%, KSS mean value 77.6 for the clinical part and 60 for the functional part, KOOS mean score 60.1, SF-12 mean score 46.1 for MCS and 35.5 for PCS. DISCUSSION The results of this retrospective study suggest that VA-LCP Curved Condylar Plates have a good functional outcome and fracture healing similar to other standard distal femoral locking plates. VA technology allows greater versatility in fractures internal fixation regardless of the plate design. Fixation devices or Prosthesis implants previously placed may be avoided, as in periprosthetic fractures. Moreover, we have not recorded any early mechanical damage. CONCLUSIONS Osteosynthesis with Synthes 4.5 mm VA-LCP Curved Condylar Plate demonstrated to have no early mechanical failure rate with good clinical and radiological results.
Collapse
Affiliation(s)
- V Campana
- Department of Orthopaedics and Traumatology, Fondazione Policlinico Universitario A. Gemelli, IRCCS, Rome, Italy; Università Cattolica del Sacro Cuore, Roma, Italia
| | - G Ciolli
- Department of Orthopaedics and Traumatology, Fondazione Policlinico Universitario A. Gemelli, IRCCS, Rome, Italy; Università Cattolica del Sacro Cuore, Roma, Italia
| | - G Cazzato
- Department of Orthopaedics and Traumatology, Fondazione Policlinico Universitario A. Gemelli, IRCCS, Rome, Italy; Università Cattolica del Sacro Cuore, Roma, Italia.
| | - E Giovannetti De Sanctis
- Department of Orthopaedics and Traumatology, Fondazione Policlinico Universitario A. Gemelli, IRCCS, Rome, Italy; Università Cattolica del Sacro Cuore, Roma, Italia
| | - C Vitiello
- Department of Radiology, Fondazione Policlinico Universitario A. Gemelli, IRCCS, Rome, Italy. Università Cattolica del Sacro Cuore, Roma, Italia
| | - A Leone
- Department of Radiology, Fondazione Policlinico Universitario A. Gemelli, IRCCS, Rome, Italy. Università Cattolica del Sacro Cuore, Roma, Italia
| | - F Liuzza
- Department of Orthopaedics and Traumatology, Fondazione Policlinico Universitario A. Gemelli, IRCCS, Rome, Italy; Università Cattolica del Sacro Cuore, Roma, Italia
| | - G Maccauro
- Department of Orthopaedics and Traumatology, Fondazione Policlinico Universitario A. Gemelli, IRCCS, Rome, Italy; Università Cattolica del Sacro Cuore, Roma, Italia
| |
Collapse
|
10
|
Hsu CL, Yang JJ, Yeh TT, Shen HC, Pan RY, Wu CC. Early fixation failure of locked plating in complex distal femoral fractures: Root causes analysis. J Formos Med Assoc 2020; 120:395-403. [PMID: 32586721 DOI: 10.1016/j.jfma.2020.06.017] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2019] [Revised: 06/06/2020] [Accepted: 06/14/2020] [Indexed: 10/24/2022] Open
Abstract
BACKGROUND/PURPOSE Orthopaedic Trauma Association (OTA) C-type distal femoral fractures can be very challenging to treat effectively. While locked plating is widely used in the complex distal femoral fracture, failure of locked plate fixation is not uncommon. First, we tried to determine the risk factor related to early failure of multiplanar OTA C-type fracture in the distal femur after fixation with lateral locked plate. Second, we tried to provide a strategy for surgeons to prevent pitfalls of early failure in the complex distal femoral fractures treated with lateral locked plating. METHODS We retrospectively reviewed 44 adults with OTA C-type fractures of the distal femur treated with locked plate fixation between 2010 and 2016 at Tri-Service General Hospital. Average length of follow-up was 27.6 months (range, 12-54 months). Univariate and multivariate logistic regression were used to determine the association of variables on early failure of fixation. A p-value < 0.05 in univariate and multivariate analyses were considered significant. RESULTS There were six patients experiencing early failure, and the early failure rate was 13.6%. The risk factors associated with early failure of complex distal femoral fracture identified by univariate analysis included sagittal oblique fracture pattern, longer working length and post-operative sagittal malalignment (odds ratio [OR] and 95% confidence intervals [CI]: 90.00 (6.85-1183.33), 0.55 (0.31-0.98) and 8.63 (1.077-69.075) respectively). The multivariate analysis showed only sagittal oblique fracture pattern was associated with early failure [OR: 52.348 (3.06-895.23)]. CONCLUSION Sagittal oblique fracture was more likely to result in early postoperative failure. Early recognition of the fracture pattern should be considered to avoid catastrophic results.
Collapse
Affiliation(s)
- Chun-Liang Hsu
- Department of Orthopedic Surgery, Tri-Service General Hospital and National Defense Medical Center, 325, Cheng-Gong Road, Section 2, Taipei, 114, Taiwan, Republic of China.
| | - Jui-Jung Yang
- Department of Orthopedic Surgery, Tri-Service General Hospital and National Defense Medical Center, 325, Cheng-Gong Road, Section 2, Taipei, 114, Taiwan, Republic of China.
| | - Tsu-Te Yeh
- Department of Orthopedic Surgery, Tri-Service General Hospital and National Defense Medical Center, 325, Cheng-Gong Road, Section 2, Taipei, 114, Taiwan, Republic of China.
| | - Hsain-Chung Shen
- Department of Orthopedic Surgery, Tri-Service General Hospital and National Defense Medical Center, 325, Cheng-Gong Road, Section 2, Taipei, 114, Taiwan, Republic of China.
| | - Ru-Yu Pan
- Department of Orthopedic Surgery, Tri-Service General Hospital and National Defense Medical Center, 325, Cheng-Gong Road, Section 2, Taipei, 114, Taiwan, Republic of China.
| | - Chia-Chun Wu
- Department of Orthopedic Surgery, Tri-Service General Hospital and National Defense Medical Center, 325, Cheng-Gong Road, Section 2, Taipei, 114, Taiwan, Republic of China.
| |
Collapse
|
11
|
Dang KH, Armstrong CA, Karia RA, Zelle BA. Outcomes of distal femur fractures treated with the Synthes 4.5 mm VA-LCP Curved Condylar Plate. INTERNATIONAL ORTHOPAEDICS 2018; 43:1709-1714. [PMID: 30267242 DOI: 10.1007/s00264-018-4177-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/12/2018] [Accepted: 09/18/2018] [Indexed: 10/28/2022]
Abstract
PURPOSE Given the recent controversy in the literature and the alarming reports of early mechanical failure associated with the use of the Synthes 4.5 mm VA-LCP Curved Condylar Plate in acute distal femur fractures, the goal of our study was to examine the outcomes and mechanical failure rates of this implant in a larger patient population. METHODS Patients 18 years of age and older who underwent plate fixation of their acute distal femoral fracture using the Synthes 4.5 mm VA-LCP Curved Condylar Plate were included in this retrospective study. The study data was collected through a retrospective chart review and review of the existing radiographic studies. Primary outcome measure was mechanical hardware failure while secondary outcome measures included nonunion, malunion, and medical and surgical complications. RESULTS A total of 74 patients (77 fractures) were included in this study. The fractures were classified according to the OTA/AO classification as 33-A2 (n = 6), 33-A3 (n = 19), 33-C1 (n = 5), 33-C2 (n = 25), and 33-C3 (n = 22). Thirty-two out of 77 fractures presented as open fractures (41.6%). A mechanical failure was observed in 7 patients (9.1%). Twenty additional patients needed a re-operation of the surgical site including two nonunion repairs, one malunion repair, 15 staged treatments of traumatic segmental bone defects, and two soft tissue debridements. CONCLUSIONS In our experience, the Synthes 4.5 mm VA-LCP Curved Condylar Plate is a safe and effective implant with a relatively low mechanical failure rate.
Collapse
Affiliation(s)
- Khang H Dang
- Department of Orthopaedics, The University of Texas Health Science Center at San Antonio, 7703 Floyd Curl Dr, MC-7774, San Antonio, TX, 78229, USA
| | - Connor A Armstrong
- Department of Orthopaedics, The University of Texas Health Science Center at San Antonio, 7703 Floyd Curl Dr, MC-7774, San Antonio, TX, 78229, USA
| | - Ravi A Karia
- Department of Orthopaedics, The University of Texas Health Science Center at San Antonio, 7703 Floyd Curl Dr, MC-7774, San Antonio, TX, 78229, USA
| | - Boris A Zelle
- Department of Orthopaedics, The University of Texas Health Science Center at San Antonio, 7703 Floyd Curl Dr, MC-7774, San Antonio, TX, 78229, USA.
| |
Collapse
|
12
|
Chen J, Lu H. [Current status and progress of clinical research on distal femoral fractures]. ZHONGGUO XIU FU CHONG JIAN WAI KE ZA ZHI = ZHONGGUO XIUFU CHONGJIAN WAIKE ZAZHI = CHINESE JOURNAL OF REPARATIVE AND RECONSTRUCTIVE SURGERY 2018; 32:242-247. [PMID: 29806419 DOI: 10.7507/1002-1892.201704132] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
Objective To investigate current status and latest progress of clinical research on distal femoral fractures. Methods The related literature was extensively reviewed to summarize the trend of the researches and their clinical application in the treatment of distal femoral fractures. Results Distal femoral fractures are likely to occur in young people who suffer from high-energy damage and the elderly with osteoporosis, which is always comminuted and unstable fractures, and often involved in the articular surface and combined with serious soft tissue injury. Therefore, the treatment faces many challenges. External fixation is now used as a temporary means of controlling injury. The vast majority of patients are feasible to internal fixation, including plates system and intramedullary nail system. Different internal fixator also has its own characteristics, such as double plates can strengthen the medial support of the femur, less invasive stabilization system protects the blood supply of fractures, distal cortial locking plate is theoretically more fit for the requirements of bone healing, retrograde intramedullary nail can resist varus and valgus. Conclusion The treatment of distal femoral fractures should be based on the type of fracture and the characteristics of internal fixators.
Collapse
Affiliation(s)
- Jishizhan Chen
- Department of Orthopaedics, Xin Hua Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai, 200092, P.R.China
| | - Hua Lu
- Department of Orthopaedics, Xin Hua Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai, 200092,
| |
Collapse
|
13
|
Wang S, Wu S, You M, Li Q, Zheng F. [One-stage total knee arthroplasty for femoral supracondylar fracture combined with knee osteoarthritis]. ZHONGGUO XIU FU CHONG JIAN WAI KE ZA ZHI = ZHONGGUO XIUFU CHONGJIAN WAIKE ZAZHI = CHINESE JOURNAL OF REPARATIVE AND RECONSTRUCTIVE SURGERY 2017; 31:1423-1427. [PMID: 29806380 DOI: 10.7507/1002-1892.201707071] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
Objective To evaluate the effectiveness of one-stage total knee arthroplasty (TKA) for femoral supracondylar fracture combined with knee osteoarthritis. Methods Between January 2012 and March 2015, a total of 19 patients (19 knees) with femoral supracondylar fracture and knee osteoarthritis were treated with one-stage TKA. Of 19 cases, 8 were male and 11 were female with an average age of 69.6 years (range, 60-85 years). The mean body mass index was 22.6 kg/m 2 (range, 22.0-27.5 kg/m 2). The left knee was involved in 13 cases, and the right knee in 6 cases. The causes of femoral supracondylar fracture were falls in 10 cases, traffic accidents in 8 cases, and other injury in 1 case. All fractures were classified as type A according to AO/Association for the Study of Internal Fixation (AO/ASIF) classification. The interval of injury and operation was 4-13 days (mean, 8.6 days). The disease duration of osteoarthritis ranged from 30 to 90 months (mean, 52.6 months). During follow-up, the knee society score (KSS) and the range of motion (ROM) were used to evaluate the knee function; anteroposterior and lateral X-ray films of the knee were used to observe the position of the prosthesis. Results All the incisions healed at the first stage, and there was no early complication such as pulmonary infection, pressure ulcer, and urinary tract infection. All patients were followed up 2-4 years with an average of 2.6 years. The ROM and KSS functional scores and clinical scores were significantly improved at 15 days and 2 years after operation, showing significant differences when compared with those before operation ( P<0.05). There were significant differences in the ROM and KSS functional scores and clinical scores between two time points after operation ( P<0.05). X-ray films showed the fracture bone healing, good alignment, no loosening of prosthesis at 2 years after operarion. Conclusion One-stage TKA for femoral supracondylar fracture combined with knee osteoarthritis can achieve good effectiveness. It can not only reconstruct joint function, but also cure osteoarthritis and fracture at the same time, shorten the healing time, reduce the incidence of related complications.
Collapse
Affiliation(s)
- Shangzeng Wang
- Department of Orthopaedics, the Second Affiliated Hospital of Henan University of Traditional Chinese Medicine, Zhengzhou Henan, 450002, P.R.China
| | - Shengchao Wu
- Postgraduate School, Henan University of Traditional Chinese Medicine, Zhengzhou Henan, 450046, P.R.China
| | - Mingcan You
- Postgraduate School, Henan University of Traditional Chinese Medicine, Zhengzhou Henan, 450046, P.R.China
| | - Qiang Li
- Postgraduate School, Henan University of Traditional Chinese Medicine, Zhengzhou Henan, 450046, P.R.China
| | - Fuzeng Zheng
- Department of Orthopaedics, the Second Affiliated Hospital of Henan University of Traditional Chinese Medicine, Zhengzhou Henan, 450002,
| |
Collapse
|
14
|
Abstract
OBJECTIVES To document the high failure rate of a specific implant: the Synthes Variable Angle (VA) Locking Distal Femur Plate. DESIGN Retrospective. SETTING Urban University Level I Trauma Center. PATIENT/PARTICIPANTS All distal femur fractures (OTA/AO 33-A, B, C) treated from March 2011 through August 2013 were reviewed from our institutional orthopaedic trauma registry. Inclusion criteria were fractures treated with a precontoured distal femoral locking plate and age between 18 and 84. Exclusion criteria were fractures treated with intramedullary nails, arthroplasty, non-precontoured plates, dual plating, or screw fixation alone. The population was divided into 3 groups: less invasive stabilization system (LISS) group (n = 21), treated with LISS plates (Synthes, Paoli, PA); locking condylar plates (LCPs) group (n = 10), treated with LCPs (Synthes, Paoli, PA); and VA group (n = 36), treated with VA distal femoral LCPs (Synthes, Paoli, PA). Average age was 54.6 ± 17.5 years. INTERVENTION Open reduction internal fixation with one of the above implants was performed. MAIN OUTCOME MEASURES The patients were followed radiographically for early mechanical implant failure defined as loosening of locking screws, loss of fixation, plate bending, or implant failure. RESULTS There were no statistically significant differences between groups for age, gender, open fracture, mechanism of injury, or medial comminution. There were 3 failures (14.3%) in group LISS, no failures (0%) in group LCP, and 8 failures (22.2%) in group VA. All 3 failures in group LISS were in A-type fractures (2 periprosthetic) and all failures in group VA were in C-type fractures. When all fractures for all 3 groups were compared for failure rate, there was no statistically significant difference (P = 0.23). However, when only 33-C fractures were compared, there was significantly greater failure rate in the VA group (P = 0.03). The mean time to failure in group VA was 147 days (range 24-401 days) and was significantly earlier (P = 0.034) when compared with group LISS (mean 356 days; range 251-433 days). CONCLUSIONS Early mechanical failure with the VA distal femoral locking plate is higher than traditional locking plates (LCP and LISS) for OTA/AO 33-C fractures. We caution practicing surgeons against the use of this plate for metaphyseal fragmented distal femur fractures. LEVEL OF EVIDENCE Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
Collapse
|
15
|
Lampropoulou-Adamidou K, Tosounidis TH, Kanakaris NK, Ekkernkamp A, Wich M, Giannoudis PV. The outcome of Polyax Locked Plating System for fixation distal femoral non-implant related and periprosthetic fractures. Injury 2015; 46 Suppl 5:S18-24. [PMID: 26343298 DOI: 10.1016/j.injury.2015.08.008] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
The objective of this study was to report on the safety, efficacy and clinical outcomes of the Polyax Locked Plating System (Biomet, Warsaw, IN, USA) in the management of acute (non-implant related and periprosthetic) distal femoral fractures. We retrospectively reviewed 71 patients with 73 distal femoral fractures. Thirty-three of the included fractures occurred around previously placed implants. The average patients' age was 67 years (range 18-98). There were 7 early postoperative complications (9.5%) including one deep surgical site infection, 2 pulmonary embolisms and 4 urinary or respiratory infections. At final follow-up (mean 12, range 9-55 months) all fractures progressed to clinical and radiological union. However, major revision surgery for healing problems was required in 5 cases (6.8%) and minor in 3 cases (4.1%). The average time to healing was 6 (range 3-23) months. Angulation less than 5 degrees in any plane was observed in 66 cases (89.7%), within 5-10 degrees in 5 cases (7.3%) and within 10-15 degrees in 2 cases (2.9%). The mean pre-injury and final follow-up values of Glasgow Outcome Scale were 1.5(1-3) and 1.7(1-3) respectively. Overall 61 patients (83.53%) retained their pre-injury activity status. The Polyax Locked Plating System offers a safe and efficient fixation in distal femoral fractures.
Collapse
Affiliation(s)
- Kalliopi Lampropoulou-Adamidou
- Academic Department of Trauma & Orthopaedic Surgery, University of Leeds, Clarendon Wing, Floor A, Great George Street, Leeds General Infirmary, LS1 3EX Leeds, UK
| | - Theodoros H Tosounidis
- Academic Department of Trauma & Orthopaedic Surgery, University of Leeds, Clarendon Wing, Floor A, Great George Street, Leeds General Infirmary, LS1 3EX Leeds, UK; NIHR Leeds Biomedical Research Unit, Chapel Allerton Hospital, West Yorkshire, LS7 4SA Leeds, UK
| | - Nikolaos K Kanakaris
- Academic Department of Trauma & Orthopaedic Surgery, University of Leeds, Clarendon Wing, Floor A, Great George Street, Leeds General Infirmary, LS1 3EX Leeds, UK
| | - Axel Ekkernkamp
- Department of Trauma and Orthopedic Surgery, Unfallkrankenhaus Berlin, Warener Str. 7, 12683 Berlin, Germany
| | - Michael Wich
- Department of Trauma and Orthopedic Surgery, Unfallkrankenhaus Berlin, Warener Str. 7, 12683 Berlin, Germany; Klinikum Dahme-Spreewald, Koepenicker Str. 29, 15711 Koenigs Wusterhausen, Germany
| | - Peter V Giannoudis
- Academic Department of Trauma & Orthopaedic Surgery, University of Leeds, Clarendon Wing, Floor A, Great George Street, Leeds General Infirmary, LS1 3EX Leeds, UK; NIHR Leeds Biomedical Research Unit, Chapel Allerton Hospital, West Yorkshire, LS7 4SA Leeds, UK.
| |
Collapse
|