1
|
Wu J, Tong X, Liu Q, Cao Y, Zhao Y, Wang S. Microsurgical ligation for incompletely coiled or recurrent intracranial aneurysms: a 17-year single-center experience. Chin Neurosurg J 2019; 5:7. [PMID: 32922907 PMCID: PMC7398258 DOI: 10.1186/s41016-019-0153-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2018] [Accepted: 01/30/2019] [Indexed: 11/10/2022] Open
Abstract
Background In this retrospective single-center study, we presented our experience in the microsurgical management of incompletely coiled or recurrent aneurysms after initial endovascular coiling. Methods During a 17-year period, 48 patients underwent microsurgical clipping of incompletely coiled or recurrent aneurysms after coiling (Gurian group B). The clinical data, surgical technique, and postoperative outcome were recorded and analyzed. Results Before coiling, 42 patients (87.5%) experienced aneurysm rupture. Most of the aneurysms (46/48, 96%) were located in the anterior circulation. After coiling, 6 patients had incompletely coiled aneurysms and 42 patients had recurrent aneurysms, with a mean time of 20.2 months from coiling to recurrence. Coil extrusion occurred in none of the incompletely coiled aneurysms and 71% (30/42) of the recurrent aneurysms. Clipping techniques are direct microsurgical clipping without coil removal in 16 patients, partial coil removal in 14 patients, and total coil removal in 18 patients. Postoperative and follow-up angiography revealed complete occlusion of the aneurysms in all patients. No patient died during postoperative follow-up period (mean, 78.9 months; range, 10-190 months). Good outcomes (GOS of 4 or 5) were achieved in 87.5% (42/48) of the patients at the final follow-up. Conclusions Microsurgical clipping is effective for incompletely coiled or recurrent aneurysms after initial coiling. For recurrent aneurysms that have coils in the neck, have no adequate neck for clipping, or cause mass effects on surrounding structures, partial or total removal of coiled mass can facilitate surgical clipping and lead to successful obliteration of the aneurysms.
Collapse
Affiliation(s)
- Jun Wu
- Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, 100050 China.,China National Clinical Research Center for Neurological Diseases, Beijing, China.,Center of Stroke, Beijing Institute for Brain Disorders, Beijing, China.,Beijing Key Laboratory of Translational Medicine for Cerebrovascular Diseases, Beijing, People's Republic of China
| | - Xianzeng Tong
- Department of Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing, China
| | - Qingyuan Liu
- Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, 100050 China.,China National Clinical Research Center for Neurological Diseases, Beijing, China.,Center of Stroke, Beijing Institute for Brain Disorders, Beijing, China.,Beijing Key Laboratory of Translational Medicine for Cerebrovascular Diseases, Beijing, People's Republic of China
| | - Yong Cao
- Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, 100050 China.,China National Clinical Research Center for Neurological Diseases, Beijing, China.,Center of Stroke, Beijing Institute for Brain Disorders, Beijing, China.,Beijing Key Laboratory of Translational Medicine for Cerebrovascular Diseases, Beijing, People's Republic of China
| | - Yuanli Zhao
- Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, 100050 China.,China National Clinical Research Center for Neurological Diseases, Beijing, China.,Center of Stroke, Beijing Institute for Brain Disorders, Beijing, China.,Beijing Key Laboratory of Translational Medicine for Cerebrovascular Diseases, Beijing, People's Republic of China
| | - Shuo Wang
- Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, 100050 China.,China National Clinical Research Center for Neurological Diseases, Beijing, China.,Center of Stroke, Beijing Institute for Brain Disorders, Beijing, China.,Beijing Key Laboratory of Translational Medicine for Cerebrovascular Diseases, Beijing, People's Republic of China
| |
Collapse
|
2
|
Roy AK, Philipp LR, Howard BM, Cawley CM, Grossberg JA, Barrow DL. Microsurgical Treatment of Cerebral Aneurysms After Previous Endovascular Therapy: Single-Center Series and Systematic Review. World Neurosurg 2019; 123:e103-e115. [DOI: 10.1016/j.wneu.2018.11.065] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2018] [Revised: 11/07/2018] [Accepted: 11/08/2018] [Indexed: 01/01/2023]
|
3
|
Arnaout OM, El Ahmadieh TY, Zammar SG, El Tecle NE, Hamade YJ, Aoun RJN, Aoun SG, Rahme RJ, Eddleman CS, Barrow DL, Batjer HH, Bendok BR. Microsurgical Treatment of Previously Coiled Intracranial Aneurysms: Systematic Review of the Literature. World Neurosurg 2015; 84:246-53. [PMID: 25731797 DOI: 10.1016/j.wneu.2015.02.027] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2014] [Revised: 02/16/2015] [Accepted: 02/17/2015] [Indexed: 10/23/2022]
Abstract
OBJECTIVE To assess indications, complications, clinical outcomes, and technical nuances of microsurgical treatment of previously coiled intracranial aneurysms. METHODS A systematic review of the literature was performed using PubMed/MEDLINE and EMBASE databases from January 1990 to December 2013. English-language articles reporting on microsurgical treatment of previously coiled intracranial aneurysms were included. Articles that involved embolization materials other than coils were excluded. Data on aneurysm characteristics, indications for surgery, techniques, complications, angiographic obliteration rates, and clinical outcomes were collected. RESULTS The literature review identified 29 articles reporting on microsurgical clipping of 375 previously coiled aneurysms. Of the aneurysms, 68% were small (<10 mm). Indications for clipping included the presence of a neck remnant (48%) and new aneurysmal growth (45%). Rebleeding before clipping was reported in 6% of cases. Coil extraction was performed in 13% of cases. The median time from initial coiling to clipping was 7 months. The angiographic cure rate was 93%, with morbidity and mortality of 9.8% and 3.6%, respectively. CONCLUSIONS Microsurgical clipping of previously coiled aneurysms can result in high obliteration rates with relatively low morbidity and mortality in select cases. Considerations for microsurgical strategies include the presence of sufficient aneurysmal tissue for clip placement and the potential need for temporary occlusion or flow arrest. Coil extraction is not needed in most cases.
Collapse
Affiliation(s)
- Omar M Arnaout
- Department of Neurological Surgery, Northwestern Memorial Hospital, Chicago, Illinois, USA
| | - Tarek Y El Ahmadieh
- Department of Neurological Surgery, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| | - Samer G Zammar
- Department of Neurological Surgery, Northwestern Memorial Hospital, Chicago, Illinois, USA
| | - Najib E El Tecle
- Department of Neurological Surgery, Northwestern Memorial Hospital, Chicago, Illinois, USA
| | - Youssef J Hamade
- Department of Neurological Surgery, Mayo Clinic Hospital, Phoenix, Arizona, USA
| | - Rami James N Aoun
- Department of Neurological Surgery, Mayo Clinic Hospital, Phoenix, Arizona, USA
| | - Salah G Aoun
- Department of Neurological Surgery, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| | - Rudy J Rahme
- Department of Neurological Surgery, Northwestern Memorial Hospital, Chicago, Illinois, USA
| | - Christopher S Eddleman
- Department of Neurological Surgery, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| | - Daniel L Barrow
- Department of Neurological Surgery, Mayo Clinic Hospital, Phoenix, Arizona, USA; Department of Neurological Surgery, Emory University School of Medicine, Atlanta, Georgia, USA
| | - H Hunt Batjer
- Department of Neurological Surgery, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| | - Bernard R Bendok
- Department of Neurological Surgery, Mayo Clinic Hospital, Phoenix, Arizona, USA.
| |
Collapse
|
4
|
Mohammadi AR, Chen K, Ali MSM, Takahata K. Radio aneurysm coils for noninvasive detection of cerebral embolization failures: a preliminary study. Biosens Bioelectron 2011; 30:300-5. [PMID: 22014417 DOI: 10.1016/j.bios.2011.09.033] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2011] [Revised: 09/23/2011] [Accepted: 09/24/2011] [Indexed: 11/27/2022]
Abstract
The rupture of a cerebral aneurysm is the most common cause of subarachnoid hemorrhage. Endovascular embolization of the aneurysms by implantation of Guglielmi detachable coils (GDC) has become a major treatment approach in the prevention of a rupture. Implantation of the coils induces formation of tissues over the coils, embolizing the aneurysm. However, blood entry into the coiled aneurysm often occurs due to failures in the embolization process. Current diagnostic methods used for aneurysms, such as X-ray angiography and computer tomography, are ineffective for continuous monitoring of the disease and require extremely expensive equipment. Here we present a novel technique for wireless monitoring of cerebral aneurysms using implanted embolization coils as radiofrequency resonant sensors that detect the blood entry. The experiments show that commonly used embolization coils could be utilized as electrical inductors or antennas. As the blood flows into a coil-implanted aneurysm, parasitic capacitance of the coil is modified because of the difference in permittivity between the blood and the tissues grown around the coil, resulting in a change in the coil's resonant frequency. The resonances of platinum GDC-like coils embedded in aneurysm models are detected to show average responses of 224-819 MHz/ml to saline injected into the models. This preliminary demonstration indicates a new possibility in the use of implanted GDC as a wireless sensor for embolization failures, the first step toward realizing long-term, noninvasive, and cost-effective remote monitoring of cerebral aneurysms treated with coil embolization.
Collapse
Affiliation(s)
- Abdolreza Rashidi Mohammadi
- Department of Electrical & Computer Engineering, University of British Columbia, Vancouver, BC, V6T 1Z4 Canada
| | | | | | | |
Collapse
|
5
|
Raftopoulos C, Vaz G. Surgical indications and techniques for failed coiled aneurysms. Adv Tech Stand Neurosurg 2011; 36:199-226. [PMID: 21197612 DOI: 10.1007/978-3-7091-0179-7_8] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
For two decades, endovascular coiling has revolutionized the treatment of intracranial aneurysms. However, as with all techniques, it has limitations and endovascular radiologists and neurosurgeons are regularly confronted by what we call "failed" coiled aneurysms. Failed coiled aneurysms can occur in different situations: a) presence of a significant remnant at the end of an endovascular procedure; b) recanalization of an initially satisfactory occlusion; and c) coil extrusion deemed too thrombogenic or threatening the blood flow in the parent vessel. We and other teams around the world have developed strategies to manage these difficult cases. Here, we compare our own experience with other reports in the literature.
Collapse
Affiliation(s)
- C Raftopoulos
- Department of Neurosurgery, University Hospital St-Luc, Université Catholique de Louvain (UCL), Brussels, Belgium
| | | |
Collapse
|
6
|
Nair MK, Pettigrew JC, Mancuso AA. Intracranial aneurysm as an incidental finding. Dentomaxillofac Radiol 2007; 36:107-12. [PMID: 17403890 DOI: 10.1259/dmfr/16588494] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
This report presents an incidental finding of a potentially life-threatening large fusiform aneurysm of the internal carotid artery at the level of the posterior communicating artery in a patient who reported with complaints relating to the presence of a radiolucent lesion in the mandible that was diagnosed as odontogenic keratocyst. This case highlights the need to study a case in detail in preparation for prescribing the appropriate advanced imaging modality examination, and also to carefully evaluate the entire imaged volume for incidental pathology and not just the region of interest. This report assumes significance in the light of widespread use of cone beam CT by dental clinicians for routine diagnostic tasks without a formal interpretation being carried out on all such studies.
Collapse
Affiliation(s)
- M K Nair
- Oral and Maxillofacial Radiology, University of Florida College of Dentistry, Box 100414, JHMHC, Gainesville, FL 32610-0414, USA.
| | | | | |
Collapse
|