Layman RR, Leng S, Boedeker KL, Burk LM, Dang H, Duan X, Jacobsen MC, Li B, Li K, Little K, Madhav P, Miller J, Nute JL, Giraldo JCR, Ruchala KJ, Tao S, Varchena V, Vedantham S, Zeng R, Zhang D. AAPM Task Group Report 299: Quality control in multi-energy computed tomography. Med Phys 2024. [PMID: 39072826 DOI: 10.1002/mp.17322] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2023] [Revised: 05/23/2024] [Accepted: 05/27/2024] [Indexed: 07/30/2024] Open
Abstract
Multi-energy computed tomography (MECT) offers the opportunity for advanced visualization, detection, and quantification of select elements (e.g., iodine) or materials (e.g., fat) beyond the capability of standard single-energy computed tomography (CT). However, the use of MECT requires careful consideration as substantially different hardware and software approaches have been used by manufacturers, including different sets of user-selected or hidden parameters that affect the performance and radiation dose of MECT. Another important consideration when designing MECT protocols is appreciation of the specific tasks being performed; for instance, differentiating between two different materials or quantifying a specific element. For a given task, it is imperative to consider both the radiation dose and task-specific image quality requirements. Development of a quality control (QC) program is essential to ensure the accuracy and reproducibility of these MECT applications. Although standard QC procedures have been well established for conventional single-energy CT, the substantial differences between single-energy CT and MECT in terms of system implementations, imaging protocols, and clinical tasks warrant QC tests specific to MECT. This task group was therefore charged with developing a systematic QC program designed to meet the needs of MECT applications. In this report, we review the various MECT approaches that are commercially available, including information about hardware implementation, MECT image types, image reconstruction, and postprocessing techniques that are unique to MECT. We address the requirements for MECT phantoms, review representative commercial MECT phantoms, and offer guidance regarding homemade MECT phantoms. We discuss the development of MECT protocols, which must be designed carefully with proper consideration of MECT technology, imaging task, and radiation dose. We then outline specific recommended QC tests in terms of general image quality, radiation dose, differentiation and quantification tasks, and diagnostic and therapeutic applications.
Collapse
Affiliation(s)
- Rick R Layman
- Department of Imaging Physics, University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Shuai Leng
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA
| | | | - Laurel M Burk
- U.S. Food and Drug Administration, Silver Spring, Maryland, USA
| | | | - Xinhui Duan
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| | - Megan C Jacobsen
- Department of Imaging Physics, University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Baojun Li
- Department of Radiology, Boston University Medical Center, Boston, Massachusetts, USA
| | - Ke Li
- Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Kevin Little
- Department of Radiology, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA
| | | | - Jessica Miller
- Department of Human Oncology, University of Wisconsin-Madison, Madison, WI, USA
| | - Jessica L Nute
- Department of Radiology, University of Texas Health Science Center at San Antonio, San Antonio, Texas, USA
| | | | | | - Shengzhen Tao
- Department of Radiology, Mayo Clinic, Jacksonville, Florida, USA
| | | | | | - Rongping Zeng
- U.S. Food and Drug Administration, Silver Spring, Maryland, USA
| | - Da Zhang
- Department of Radiology, Beth Israel Deaconess Medical Center, Boston, Massachusetts, USA
| |
Collapse
|
2
|
Reizine E, Blain M, Pescatori L, Longère B, Ingels A, Boughamni W, Bouanane M, Mulé S, Luciani A. Applicability of Bosniak 2019 for renal mass classification on portal venous phase at the era of spectral CT imaging using rapid kV-switching dual-energy CT. Eur Radiol 2024; 34:1816-1824. [PMID: 37667141 DOI: 10.1007/s00330-023-10145-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2023] [Revised: 05/30/2023] [Accepted: 07/10/2023] [Indexed: 09/06/2023]
Abstract
OBJECTIVES To evaluate the applicability of Bosniak 2019 criteria on a monophasic portal venous phase using rapid kilovoltage-switching DECT (rsDECT). MATERIALS AND METHODS One hundred twenty-seven renal masses assessed on rsDECT were included, classified according to Bosniak 2019 classification using MRI as the reference standard. Using the portal venous phase, virtual monochromatic images at 40, 50, and 77 keV; virtual unenhanced (VUE) images; and iodine map images were reconstructed. Changes in attenuation values between VUE and 40 keV, 50 keV, and 77 keV measurements were computed and respectively defined as ∆HU40keV, ∆HU50keV, and ∆HU77keV. The values of ∆HU40keV, ∆HU50keV, and ∆HU77keV thresholds providing the optimal diagnostic performance for the detection of internal enhancement were determined using Youden index. RESULTS Population study included 25 solid renal masses (25/127, 20%) and 102 cystic renal masses (102/127, 80%). To differentiate solid to cystic masses, the specificity of the predefined 20 HU threshold reached 88% (95%CI: 82, 93) using ∆HU77keV and 21% (95%CI: 15, 28) using ∆HU40keV. The estimated optimal threshold of attenuation change was 19 HU on ∆HU77keV, 69 HU on ∆HU50eV, and 111 HU on ∆HU40eV. The rsDECT classification was highly similar to that of MRI for solid renal masses (23/25, 92%) and for Bosniak 1 masses (62/66, 94%). However, 2 hyperattenuating Bosniak 2 renal masses (2/26, 8%) were classified as solid renal masses on rsDECT. CONCLUSION DECT is a promising tool for Bosniak classification particularly to differentiate solid from Bosniak I-II cyst. However, known enhancement thresholds must be adapted especially to the energy level of virtual monochromatic reconstructions. CLINICAL STATEMENT DECT is a promising tool for Bosniak classification; however, known enhancement thresholds must be adapted according to the types of reconstructions used and especially to the energy level of virtual monochromatic reconstructions. KEY POINTS • To differentiate solid to cystic renal masses, predefined 20 HU threshold had a poor specificity using 40 keV virtual monochromatic images. • Most of Bosniak 1 masses according to MRI were also classified as Bosniak 1 on rapid kV-switching dual-energy CT (rsDECT). • Bosniak 2 hyperattenuating renal cysts mimicked solid lesion on rsDECT.
Collapse
Affiliation(s)
- Edouard Reizine
- Department of Radiology, APHP, HU Henri Mondor, Creteil, Val-de-Marne, France.
- Faculté de Médecine, Université Paris Est Creteil, 94010, Creteil, France.
- INSERM Unit U 955, Equipe 18, 94010, Creteil, France.
- Imagerie Médicale, CHU Henri Mondor, 51 Avenue du Marechal de Lattre de Tassigny, 94010, Créteil, France.
| | - Maxime Blain
- Department of Radiology, APHP, HU Henri Mondor, Creteil, Val-de-Marne, France
- Faculté de Médecine, Université Paris Est Creteil, 94010, Creteil, France
| | - Lorenzo Pescatori
- Department of Radiology, APHP, HU Henri Mondor, Creteil, Val-de-Marne, France
| | - Benjamin Longère
- Department of Radiology, APHP, HU Henri Mondor, Creteil, Val-de-Marne, France
- University Lille, U1011 - European Genomic Institute for Diabetes, 59000, Lille, France
- INSERM U1011, 59000, Lille, France
- Department of Cardiovascular Radiology, CHU Lille, 59000, Lille, France
- Institut Pasteur Lille, 59000, Lille, France
| | | | - Wafa Boughamni
- Department of Radiology, APHP, HU Henri Mondor, Creteil, Val-de-Marne, France
| | - Mohamed Bouanane
- Department of Radiology, APHP, HU Henri Mondor, Creteil, Val-de-Marne, France
| | - Sébastien Mulé
- Department of Radiology, APHP, HU Henri Mondor, Creteil, Val-de-Marne, France
- Faculté de Médecine, Université Paris Est Creteil, 94010, Creteil, France
- INSERM Unit U 955, Equipe 18, 94010, Creteil, France
| | - Alain Luciani
- Department of Radiology, APHP, HU Henri Mondor, Creteil, Val-de-Marne, France
- Faculté de Médecine, Université Paris Est Creteil, 94010, Creteil, France
- INSERM Unit U 955, Equipe 18, 94010, Creteil, France
| |
Collapse
|
3
|
Chakravarti S, Uyeda JW. Expanding Role of Dual-Energy CT for Genitourinary Tract Assessment in the Emergency Department, From the AJR Special Series on Emergency Radiology. AJR Am J Roentgenol 2023; 221:720-730. [PMID: 37073900 DOI: 10.2214/ajr.22.27864] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/20/2023]
Abstract
Among explored applications of dual-energy CT (DECT) in the abdomen and pelvis, the genitourinary (GU) tract represents an area where accumulated evidence has established the role of DECT to provide useful information that may change management. This review discusses established applications of DECT for GU tract assessment in the emergency department (ED) setting, including characterization of renal stones, evaluation of traumatic injuries and hemorrhage, and characterization of incidental renal and adrenal findings. Use of DECT for such applications can reduce the need for additional multiphase CT or MRI examinations and reduce follow-up imaging recommendations. Emerging applications are also highlighted, including use of low-energy virtual monoenergetic images (VMIs) to improve image quality and potentially reduce contrast media doses and use of high-energy VMIs to mitigate renal mass pseudoenhancement. Finally, implementation of DECT into busy ED radiology practices is presented, weighing the trade-off of additional image acquisition, processing time, and interpretation time against potential additional useful clinical information. Automatic generation of DECT-derived images with direct PACS transfer can facilitate radiologists' adoption of DECT in busy ED environments and minimize impact on interpretation times. Using the described approaches, radiologists can apply DECT technology to improve the quality and efficiency of care in the ED.
Collapse
Affiliation(s)
| | - Jennifer W Uyeda
- Department of Emergency Radiology, Brigham and Women's Hospital/Harvard Medical School, 75 Francis St, Boston, MA 02115
| |
Collapse
|
4
|
Nehra AK, Dane B, Yeh BM, Fletcher JG, Leng S, Mileto A. Dual-Energy, Spectral and Photon Counting Computed Tomography for Evaluation of the Gastrointestinal Tract. Radiol Clin North Am 2023; 61:1031-1049. [PMID: 37758355 DOI: 10.1016/j.rcl.2023.06.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/03/2023]
Abstract
The use of dual-energy computed tomography (CT) allows for reconstruction of energy- and material-specific image series. The combination of low-energy monochromatic images, iodine maps, and virtual unenhanced images can improve lesion detection and disease characterization in the gastrointestinal tract in comparison with single-energy CT.
Collapse
Affiliation(s)
- Avinash K Nehra
- Department of Radiology, Mayo Clinic, 200 First Street Southwest, Rochester, MN 55905, USA.
| | - Bari Dane
- Department of Radiology, New York University Langone Medical Center, 550 First Avenue, New York, NY 10016, USA
| | - Benjamin M Yeh
- Department of Radiology and Biomedical Imaging, University of California, 505 Parnassus Avenue, San Francisco, CA 94143, USA
| | - Joel G Fletcher
- Department of Radiology, Mayo Clinic, 200 First Street Southwest, Rochester, MN 55905, USA
| | - Shuai Leng
- Department of Radiology, Mayo Clinic, 200 First Street Southwest, Rochester, MN 55905, USA
| | - Achille Mileto
- Department of Radiology, Virginia Mason Medical Center, 1100 9th Avenue, Seattle, WA 98101, USA
| |
Collapse
|
5
|
Chung R, Dane B, Yeh BM, Morgan DE, Sahani DV, Kambadakone A. Dual-Energy Computed Tomography: Technological Considerations. Radiol Clin North Am 2023; 61:945-961. [PMID: 37758362 DOI: 10.1016/j.rcl.2023.05.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/03/2023]
Abstract
Compared to conventional single-energy CT (SECT), dual-energy CT (DECT) provides additional information to better characterize imaged tissues. Approaches to DECT acquisition vary by vendor and include source-based and detector-based systems, each with its own advantages and disadvantages. Despite the different approaches to DECT acquisition, the most utilized DECT images include routine SECT equivalent, virtual monoenergetic, material density (eg, iodine map), and virtual non-contrast images. These images are generated either through reconstructions in the projection or image domains. Designing and implementing an optimal DECT workflow into routine clinical practice depends on radiologist and technologist input with special considerations including appropriate patient and protocol selection and workflow automation. In addition to better tissue characterization, DECT provides numerous advantages over SECT such as the characterization of incidental findings and dose reduction in radiation and iodinated contrast.
Collapse
Affiliation(s)
- Ryan Chung
- Department of Radiology, Massachusetts General Hospital, 55 Fruit Street, White 270, Boston, MA 02114, USA.
| | - Bari Dane
- Department of Radiology, NYU Langone Health, 660 1st Avenue, New York, NY 10016, USA
| | - Benjamin M Yeh
- Department of Radiology and Biomedical Imaging, University of California - San Francisco, 505 Parnassus Avenue, M391, Box 0628, San Francisco, CA 94143-0628, USA
| | - Desiree E Morgan
- Department of Radiology, University of Alabama at Birmingham, 619 19th Street, South JTN 456, Birmingham, AL 35249-6830, USA
| | - Dushyant V Sahani
- Department of Radiology, University of Washington, 1959 Northeast Pacific Street, RR220, Seattle, WA 98112, USA
| | - Avinash Kambadakone
- Department of Radiology, Massachusetts General Hospital, 55 Fruit Street, White 270, Boston, MA 02114, USA
| |
Collapse
|
6
|
Daniel S, Kopp M, Vollbrecht T, Zeilinger M, Fitz T, Muttke A, Feuerlein U, Uder M, May MS. Personalization of thoracoabdominal CT examinations using scanner integrated clinical decision support systems - Impact on the acquisition technique, scan range, and reconstruction type. Eur J Radiol 2023; 167:111078. [PMID: 37688917 DOI: 10.1016/j.ejrad.2023.111078] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2023] [Revised: 08/10/2023] [Accepted: 08/30/2023] [Indexed: 09/11/2023]
Abstract
OBJECTIVES This study evaluates the impact of a scanner-integrated, customized clinical decision support system (CDSS) on the acquisition technique, scan range, and reconstruction in thoracoabdominal CT. MATERIALS AND METHODS We applied CDSS in contrast-enhanced examinations of the trunk with various clinical indications on a recent scanner with the capability of dual-energy CT (DECT), anatomic landmark detection (ALD), and iterative metal-artifact reduction (MAR). Simple and comprehensive questions about the patient's breath hold capability, the anatomical region of interest, and metal implants can be answered after the localizer. The acquisition technique (single energy, SECT, or dual energy), scan range (chest-abdomen-pelvis or chest-abdomen), and reconstruction technique (with or without MAR) were then automatically adapted in the examination protocols in coherence with these selections. Retrospectively, we compared the usage rates for these techniques in 624 examinations on the study scanner with 740 examinations on a comparable scanner without CDSS. Subgroup analysis of effective dose (ED), scan duration, and image quality (IQ) was performed in the study group. RESULTS CDSS leads to an increased usage rate of DECT (64.4% vs. 2.8%) and MAR (75.4% vs. 44.0%). All scan range adaptations by ALD were successful. The resulting subjective IQ between single energy and DECT acquisitions was comparable (all p > 0.05). Scan duration was significantly longer in DECT than in SECT (16.9 s vs. 6.5 s; p < 0.001). However, the objective IQ was significantly higher in DECT (CNRD 2.1 vs. 1.8; p < 0.01), and the ED significantly lower (6.7 mSv vs. 7.6 mSv; p = 0.004). CONCLUSION CDSS for thoracoabdominal CT leads to a substantially increased usage rate of innovative techniques during acquisition and reconstruction. Patients with adapted protocols benefit from improved image quality and increased post-processing options at lower radiation doses.
Collapse
Affiliation(s)
- Sascha Daniel
- Departement of Radiology, University Hospital Erlangen, Friedrich-Alexander-University (FAU) Erlangen-Nuremberg, 91054, Erlangen, Germany.
| | - Markus Kopp
- Departement of Radiology, University Hospital Erlangen, Friedrich-Alexander-University (FAU) Erlangen-Nuremberg, 91054, Erlangen, Germany
| | - Thomas Vollbrecht
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Germany
| | - Martin Zeilinger
- Departement of Radiology, University Hospital Erlangen, Friedrich-Alexander-University (FAU) Erlangen-Nuremberg, 91054, Erlangen, Germany
| | - Tim Fitz
- Departement of Radiology, University Hospital Erlangen, Friedrich-Alexander-University (FAU) Erlangen-Nuremberg, 91054, Erlangen, Germany
| | | | | | - Michael Uder
- Departement of Radiology, University Hospital Erlangen, Friedrich-Alexander-University (FAU) Erlangen-Nuremberg, 91054, Erlangen, Germany; Imaging Science Institute, University Hospital Erlangen, Erlangen, Germany
| | - Matthias S May
- Departement of Radiology, University Hospital Erlangen, Friedrich-Alexander-University (FAU) Erlangen-Nuremberg, 91054, Erlangen, Germany; Imaging Science Institute, University Hospital Erlangen, Erlangen, Germany
| |
Collapse
|
7
|
Cano Alonso R, Álvarez Vázquez A, Andreu Vázquez C, Thuissard Vasallo IJ, Fernández Alfonso A, Recio Rodríguez M, Martínez de Vega V. Dual-energy CT in the differentiation between adrenal adenomas and metastases: Usefulness of material density maps and monochromatic images. RADIOLOGIA 2023; 65:402-413. [PMID: 37758331 DOI: 10.1016/j.rxeng.2021.10.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2021] [Accepted: 10/15/2021] [Indexed: 10/03/2023]
Abstract
OBJECTIVE To evaluate the behavior of adrenal adenomas and metastases with dual-energy CT, analyzing the attenuation coefficient in monochromatic images at three different levels of energy (45, 70, and 140 keV) and the tissue concentrations of fat, water, and iodine in material density maps, with the aim of establishing optimal cutoffs for differentiating between these lesions and comparing our results against published evidence. MATERIALS AND METHODS This retrospective case-control study included oncologic patients diagnosed with adrenal metastases in the 6-12 months prior to the study who were followed up in our hospital between January and June 2020. For each case (patient with metastases) included in the study, we selected a control (patient with an adrenal adenoma) with a nodule of similar size. All patients were studied with a rapid-kilovoltage-switching dual-energy CT scanner, using a biphasic acquisition protocol. We analyzed the concentration of iodine in paired water-iodine images, the concentration of fat in the paired water-fat images, and the concentration of water in the paired iodine-water and fat-water images, in both the arterial and portal phases. We also analyzed the attenuation coefficient in monochromatic images (at 55, 70, and 140 keV) in the arterial and portal phases. RESULTS In the monochromatic images, in both the arterial and portal phases, the attenuation coefficient at all energy levels was significantly higher in the group of patients with metastases than in the group of patients with adenomas. This enabled us to calculate the optimal cutoffs for classifying lesions as adenomas or metastases, except for the arterial phase at 55 KeV, where the area under the receiver operating characteristic curve (AUC) for the estimated threshold (0.68) was not considered accurate enough to classify the lesions. For the arterial phase at 70 keV, the AUC was 0.76 (95% CI: 0.663‒0.899); the optimal cutoff (42.4 HU) yielded 92% sensitivity and 60% specificity. For the arterial phase at 140 keV, the AUC was 0.94 (95% CI: 0.894‒0.999); the optimal cutoff (18.9 HU) yielded 88% sensitivity and 94% specificity). For the portal phase at 55 keV, the AUC was 0.76 (95% CI: 0.663‒0.899); the optimal cutoff (95.4 HU) yielded 68% sensitivity and 84% specificity. For the portal phase at 70 keV, the AUC was 0.82 (95% CI: 0.757‒0.955); the optimal cutoff (58.4 HU) yielded 80% sensitivity and 84% specificity. For the portal phase at 140 keV, the AUC was 0.9 (95% CI: 0.834‒0.987); the optimal cutoff (16.35 HU) yielded 96% sensitivity and 84% specificity. In the material density maps, in the arterial phase, significant differences were found only for the iodine-water pair, where the concentration of water was higher in the group with metastases (1018.8 ± 7.6 mg/cm3 vs. 998.6 ± 8.0 mg/cm3 for the group with adenomas, p < 0.001). The AUC was 0.97 (95% CI: 0.893‒0.999); the optimal cutoff (1012.5 mg/cm3) yielded 88% sensitivity and 96% specificity. The iodine-water pair was also significantly higher in metastases (1019.7 ± 12.1 mg/cm3 vs. 998.5 ± 9.1 mg/cm3 in adenomas, p < 0.001). The AUC was 0.926 (95% CI: 0.807‒0.977); the optimal cutoff (1009.5 mg/cm3) yielded 92% sensitivity and 92% specificity. Although significant results were also observed for the fat-water pair in the portal phase, the AUC was insufficient to enable a sufficiently accurate cutoff for classifying the lesions. No significant differences were found in the fat-water maps or iodine-water maps in the arterial or portal phase or in the water-fat map in the arterial phase. CONCLUSIONS Monochromatic images show differences between the behavior of adrenal adenomas and metastases in oncologic patients studied with intravenous-contrast-enhanced CT, where the group of metastases had higher attenuation than the group of adenomas in both the arterial and portal phases; this pattern is in line with the evidence published for adenomas. Nevertheless, to our knowledge, no other publications report cutoffs for this kind of differentiation in contrast-enhanced monochromatic images obtained in rapid-kilovoltage-switching dual-energy CT scanners, and this is the first new contribution of our study. Regarding the material density maps, our results suggest that the water-iodine pair is a good tool for differentiating between adrenal adenomas and metastases, in both the arterial and portal phases. We propose cutoffs for differentiating these lesions, although to our knowledge no cutoffs have been proposed for portal-phase contrast-enhanced images obtained with rapid-kilovoltage-switching dual-energy CT scanners.
Collapse
Affiliation(s)
- R Cano Alonso
- Servicio de Diagnóstico por la Imagen, Hospital Universitario QuironSalud, Pozuelo de Alarcón, Madrid, Spain.
| | - A Álvarez Vázquez
- Servicio de Diagnóstico por la Imagen, Hospital Universitario QuironSalud, Pozuelo de Alarcón, Madrid, Spain
| | - C Andreu Vázquez
- Universidad Europea de Madrid, Facultad de Ciencias Biomédicas y de la Salud, Villaviciosa de Odón, Madrid, Spain
| | - I J Thuissard Vasallo
- Universidad Europea de Madrid, Facultad de Ciencias Biomédicas y de la Salud, Villaviciosa de Odón, Madrid, Spain
| | - A Fernández Alfonso
- Servicio de Diagnóstico por la Imagen, Hospital Universitario QuironSalud, Pozuelo de Alarcón, Madrid, Spain
| | - M Recio Rodríguez
- Servicio de Diagnóstico por la Imagen, Hospital Universitario QuironSalud, Pozuelo de Alarcón, Madrid, Spain
| | - V Martínez de Vega
- Servicio de Diagnóstico por la Imagen, Hospital Universitario QuironSalud, Pozuelo de Alarcón, Madrid, Spain
| |
Collapse
|
8
|
Lee JS, Choi GM, Kim BS, Ko SY, Lee KR, Kim JJ, Kim DR. [Comparison of True and Virtual Non-Contrast Images of Liver Obtained with Single-Source Twin Beam and Dual-Source Dual-Energy CT]. JOURNAL OF THE KOREAN SOCIETY OF RADIOLOGY 2023; 84:170-184. [PMID: 36818703 PMCID: PMC9935954 DOI: 10.3348/jksr.2021.0193] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/13/2021] [Revised: 02/14/2022] [Accepted: 05/02/2022] [Indexed: 06/18/2023]
Abstract
PURPOSE To assess the magnitude of differences between attenuation values of the true non-contrast image (TNC) and virtual non-contrast image (VNC) derived from twin-beam dual-energy CT (tbDECT) and dual-source DECT (dsDECT). MATERIALS AND METHODS This retrospective study included 62 patients who underwent liver dynamic DECT with tbDECT (n = 32) or dsDECT (n = 30). Arterial VNC (AVNC), portal VNC (PVNC), and delayed VNC (DVNC) were reconstructed using multiphasic DECT. Attenuation values of multiple intra-abdominal organs (n = 11) on TNCs were subsequently compared to those on multiphasic VNCs. Further, we investigated the percentage of cases with an absolute difference between TNC and VNC of ≤ 10 Hounsfield units (HU). RESULTS For the mean attenuation values of TNC and VNC, 33 items for each DECT were compared according to the multiphasic VNCs and organs. More than half of the comparison items for each DECT showed significant differences (tbDECT 17/33; dsDECT 19/33; Bonferroni correction p < 0.0167). The percentage of cases with an absolute difference ≤ 10 HU was 56.7%, 69.2%, and 78.6% in AVNC, PVNC, and DVNC in tbDECT, respectively, and 70.5%, 78%, and 78% in dsDECT, respectively. CONCLUSION VNCs derived from the two DECTs were insufficient to replace TNCs because of the considerable difference in attenuation values.
Collapse
|
9
|
Cao J, Lennartz S, Pisuchpen N, Parakh A, Kambadakone A. Attenuation values on virtual unenhanced images obtained with detector-based dual-energy computed tomography: observations on single- and split-bolus contrast protocols. Abdom Radiol (NY) 2022; 47:3019-3027. [PMID: 34687325 DOI: 10.1007/s00261-021-03273-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2021] [Revised: 09/01/2021] [Accepted: 09/02/2021] [Indexed: 01/18/2023]
Abstract
PURPOSE To compare virtual unenhanced (VUE) attenuation values and their agreement with true unenhanced (TUE) images in patients who underwent dual-layer detector-based dual-energy computed tomography (dlDECT) with single- vs. split-bolus contrast media protocol. METHODS In this HIPAA-compliant, IRB-approved retrospective analysis, a total of 105 patients who underwent nephrographic phase (NP) dlDECT between 07/2018 and 11/2019 were included: 55 patients received single bolus and 50 patients split-bolus examinations. Both scan protocols comprised a TUE and 120-kVp NP acquisition from which VUE images were reconstructed. A radiologist performed ROI-based attenuation measurements of liver parenchyma, main portal vein, aorta, spleen, renal parenchyma, and pelvis on TUE and VUE images. Agreement between TUE and VUE images was determined and compared for both protocols and each anatomic region. RESULTS VUE attenuation was significantly higher than TUE attenuation in both cohorts in the liver, portal vein, spleen, and renal parenchyma (p < 0.05), while it was similar in the abdominal aorta in both cohorts (p = 0.05, 0.7522, respectively). VUE attenuation was significantly higher than TUE attenuation in the renal pelvis of the split-bolus cohort (p < 0.05). When comparing VUE images between single- and split-bolus protocols, the renal parenchyma yielded a significantly higher VUE attenuation in the single-bolus cohort (single bolus: 38.8 ± 3.3 HU vs. split bolus: 36.8 ± 3.6 HU; p < 0.05), whereas the split-bolus cohort revealed markedly higher VUE attenuation in the renal pelvis (single bolus: 2.3 ± 10.8 HU vs. split bolus: 92.3 ± 76.8; p < 0.05). Mean intra-patient differences between TUE and VUE images were comparable between single- and split-bolus cohorts (p-range 0.09-0.35) except for the renal parenchyma and pelvis: in the first, the single-bolus cohort yielded a higher VUE attenuation, while in the second, attenuation was significantly higher in the split-bolus cohort (p < 0.05). CONCLUSION VUE attenuation overestimated TUE attenuation and differed between split- and single-bolus protocols for the renal parenchyma and pelvis, while all other tissues showed comparable VUE attenuation.
Collapse
Affiliation(s)
- Jinjin Cao
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, White 270, Boston, MA, 02114-2696, USA
| | - Simon Lennartz
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, White 270, Boston, MA, 02114-2696, USA
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University Cologne, Kerpener Straße 62, 50937, Cologne, Germany
| | - Nisanard Pisuchpen
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, White 270, Boston, MA, 02114-2696, USA
- Department of Radiology, King Chulalongkorn Memorial Hospital, Thai Red Cross Society, Faculty of Medicine, Chulalongkorn University, Bangkok, 10330, Thailand
| | - Anushri Parakh
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, White 270, Boston, MA, 02114-2696, USA
| | - Avinash Kambadakone
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, White 270, Boston, MA, 02114-2696, USA.
| |
Collapse
|
10
|
Virarkar MK, Vulasala SSR, Gupta AV, Gopireddy D, Kumar S, Hernandez M, Lall C, Bhosale P. Virtual Non-contrast Imaging in The Abdomen and The Pelvis: An Overview. Semin Ultrasound CT MR 2022; 43:293-310. [PMID: 35738815 DOI: 10.1053/j.sult.2022.03.004] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Virtual non-contrast (VNC) imaging is a post-processing technique generated from contrast-enhanced scans using dual-energy computed tomography (DECT). It is generated by removing iodine from imaging acquired at multiple energies. Myriad clinical studies have shown its ability to diagnose the various abdominal and pelvic pathologies discussed in the article. VNC is also a problem-solving tool for characterizing incidentally detected lesions ("incidentalomas"), often decreasing the need for additional follow-up imaging. It also obviates the multiphase image acquisitions to evaluate hematuria, hepatic steatosis, aortic endoleaks, and gastrointestinal bleeding by generating image datasets from different tissue attenuation values. The scope of this article is to provide an overview of various applications of VNC imaging obtained by DECT in the abdomen and pelvis.
Collapse
Affiliation(s)
- Mayur K Virarkar
- Department of Radiology, University of Florida College of Medicine, Jacksonville, FL
| | | | | | | | - Sindhu Kumar
- Department of Radiology, University of Florida College of Medicine, Jacksonville, FL
| | - Mauricio Hernandez
- Department of Radiology, University of Florida College of Medicine, Jacksonville, FL
| | - Chandana Lall
- Department of Radiology, University of Florida College of Medicine, Jacksonville, FL
| | - Priya Bhosale
- Department of Diagnostic Radiology, Division of Diagnostic Imaging, The University of Texas MD Anderson Cancer Center, Houston, TX
| |
Collapse
|
11
|
Mahmood A, Iqbal J. Purinergic receptors modulators: An emerging pharmacological tool for disease management. Med Res Rev 2022; 42:1661-1703. [PMID: 35561109 DOI: 10.1002/med.21888] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2021] [Revised: 03/16/2022] [Accepted: 05/04/2022] [Indexed: 11/10/2022]
Abstract
Purinergic signaling is mediated through extracellular nucleotides (adenosine 5'-triphosphate, uridine-5'-triphosphate, adenosine diphosphate, uridine-5'-diphosphate, and adenosine) that serve as signaling molecules. In the early 1990s, purines and pyrimidine receptors were cloned and characterized drawing the attention of scientists toward this aspect of cellular signaling. This signaling pathway is comprised of four subtypes of adenosine receptors (P1), eight subtypes of G-coupled protein receptors (P2YRs), and seven subtypes of ligand-gated ionotropic receptors (P2XRs). In current studies, the pathophysiology and therapeutic potentials of these receptors have been focused on. Various ligands, modulating the functions of purinergic receptors, are in current clinical practices for the treatment of various neurodegenerative disorders and cardiovascular diseases. Moreover, several purinergic receptors ligands are in advanced phases of clinical trials as a remedy for depression, epilepsy, autism, osteoporosis, atherosclerosis, myocardial infarction, diabetes, irritable bowel syndrome, and cancers. In the present study, agonists and antagonists of purinergic receptors have been summarized that may serve as pharmacological tools for drug design and development.
Collapse
Affiliation(s)
- Abid Mahmood
- Centre for Advanced Drug Research, COMSATS University Islamabad, Abbottabad, Pakistan
| | - Jamshed Iqbal
- Centre for Advanced Drug Research, COMSATS University Islamabad, Abbottabad, Pakistan
| |
Collapse
|
12
|
Shern Liang E, Wastney T, Dobeli K, Hacking C. Virtual non-contrast detector-based spectral CT predictably overestimates tissue density for the characterisation of adrenal lesions compared to true non-contrast CT. Abdom Radiol (NY) 2022; 47:2462-2467. [PMID: 35562563 DOI: 10.1007/s00261-022-03528-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2022] [Revised: 04/08/2022] [Accepted: 04/11/2022] [Indexed: 11/24/2022]
Abstract
PURPOSE To establish if virtual non-contrast (VNC) images generated from contrast-enhanced detector-based spectral CT could replace true non-contrast (TNC) imaging for the characterisation of adrenal masses. METHODS TNC and VNC images were retrospectively reviewed for 39 patients with one or more adrenal lesions who underwent contrast-enhanced spectral CT of the upper abdomen. Lesions were categorised as either 'adenoma' or 'indeterminate/other lesion' based on current reference standards. The CT density of each lesion was measured on both image sets by two readers and compared using Wilcoxon signed-rank test. ROC analysis with Youden's J index method was performed to determine the optimal attenuation cut-off for diagnosing benign adenoma on VNC images. RESULTS Forty-four lesions were included, 37 of which were diagnosed as adenomas. There were significant differences between TNC and VNC measurements for both readers (mean difference 9.1 HU for reader 1; 9.8 HU for reader 2; p < 0.01). Optimal attenuation thresholds for diagnosing adenomas on VNC were 25.3 HU (reader 1) and 23.9 HU (reader 2) for the entire population, and 18.3 HU (reader 1) and 19.7 HU (reader 2) for lipid-rich adenomas < 10 HU on TNC imaging. CONCLUSION There is insufficient evidence to support the use of VNC as a substitute for TNC images in the characterisation of adrenal lesions. VNC using a detector-based spectral CT scanner shows a predictable increase in attenuation values compared to TNC. Thus, future studies might be better directed towards finding a new threshold value for diagnosing benign adrenal adenomas on VNC imaging.
Collapse
Affiliation(s)
- Ee Shern Liang
- Department of Medical Imaging, Royal Brisbane and Women's Hospital, Brisbane, QLD, Australia.
| | - Timothy Wastney
- Department of Medical Imaging, Royal Brisbane and Women's Hospital, Brisbane, QLD, Australia
| | - Karen Dobeli
- Department of Medical Imaging, Royal Brisbane and Women's Hospital, Brisbane, QLD, Australia
| | - Craig Hacking
- Department of Medical Imaging, Royal Brisbane and Women's Hospital, Brisbane, QLD, Australia
- University of Queensland, Saint Lucia, QLD, Australia
| |
Collapse
|
13
|
Lennartz S, Pisuchpen N, Parakh A, Cao J, Baliyan V, Sahani D, Hahn PF, Kambadakone A. Virtual Unenhanced Images: Qualitative and Quantitative Comparison Between Different Dual-Energy CT Scanners in a Patient and Phantom Study. Invest Radiol 2022; 57:52-61. [PMID: 34162795 DOI: 10.1097/rli.0000000000000802] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
MATERIALS AND METHODS Forty-four patients with clinical contrast-enhanced abdominal examinations on each of the 3 DECT scanner types and a phantom scanned with the same protocols were included in this retrospective study. Qualitative and quantitative assessment was performed on VUE images. Quantitative evaluation included measurement of attenuation and image noise for various tissues and the phantom. Virtual unenhanced image attenuation and noise were compared between scanner types, and intrapatient interscanner reproducibility of virtual unenhanced image attenuation was calculated as the percentage of measurement pairs with an interscanner difference ≤ 10 HU. Image quality, noise, sharpness, and iodine elimination were assessed qualitatively by 2 radiologists. RESULTS Significant interscanner differences in VUE attenuation and noise were found in all tissues. dlDECT and rsDECT showed significantly higher VUE attenuation than dsDECT in the aorta, portal vein, and kidneys (P < 0.05). Conversely, VUE attenuation in dsDECT was significantly higher than in dlDECT/rsDECT for subcutaneous and retroperitoneal fat (both P < 0.05). A total of 91.9% (385/419) of measurements were reproducible between rsDECT and dlDECT, 70.9% (297/419) between dsDECT and rsDECT, and 66.8% (280/419) between dsDECT and dlDECT. Virtual unenhanced image attenuation in the contrast media-filled phantom cavity was 12.7 ± 4.7 HU in dlDECT, -5.3 ± 4.2 HU in rsDECT, and -4.0 ± 10.7 HU in dsDECT with significant differences between dlDECT and rsDECT/dsDECT, respectively (P < 0.05), between which attenuation was comparable in the unenhanced extraluminal phantom component (P = 0.11-0.62). Qualitatively, dsDECT yielded best iodine elimination, whereas sharpness, image noise, and overall image quality were rated higher in dlDECT and rsDECT. CONCLUSIONS There are significant interscanner differences in the attenuation measurements and qualitative assessment of VUE images, which should be acknowledged when using these images in patients that are being scanned on different DECT scanner types during imaging follow-up.
Collapse
Affiliation(s)
| | | | - Anushri Parakh
- From the Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA
| | - Jinjin Cao
- From the Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA
| | - Vinit Baliyan
- From the Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA
| | - Dushyant Sahani
- Department of Radiology, University of Washington, Seattle, WA
| | - Peter F Hahn
- From the Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA
| | - Avinash Kambadakone
- From the Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA
| |
Collapse
|
14
|
Cano Alonso R, Álvarez Vázquez A, Andreu Vázquez C, Thuissard Vasallo I, Fernández Alfonso A, Recio Rodríguez M, Martínez de Vega V. Tomografía computarizada con energía espectral en la diferenciación de los adenomas y metástasis suprarrenales: utilidad de los mapas de descomposición de materiales y de imágenes monocromáticas. RADIOLOGIA 2021. [DOI: 10.1016/j.rx.2021.10.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
15
|
Nagayama Y, Inoue T, Oda S, Tanoue S, Nakaura T, Morinaga J, Ikeda O, Hirai T. Unenhanced Dual-Layer Spectral-Detector CT for Characterizing Indeterminate Adrenal Lesions. Radiology 2021; 301:369-378. [PMID: 34427466 DOI: 10.1148/radiol.2021202435] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Background Unenhanced dual-layer spectral-detector CT may facilitate adrenal lesion characterization; however, no studies have evaluated its incremental diagnostic yield for indeterminate lesions (unenhanced attenuation >10 HU) in comparison to that with conventional unenhanced CT. Purpose To determine whether spectral attenuation analysis improves characterization of lipid-poor adrenal adenomas from nonadenomas compared to that with mean attenuation and histogram analysis of conventional CT images. Materials and Methods This retrospective study included patients with indeterminate adrenal lesions who underwent unenhanced dual-layer spectral-detector CT between March 2018 and June 2020. Mean attenuation on conventional 120-kVp images (HUconv), histogram-based percentage negative pixels (proportion of all pixels <0 HU) on conventional 120-kVp images, and mean attenuation on virtual monoenergetic images (VMIs) at 40-140 keV were measured for each lesion. The attenuation difference between virtual monoenergetic 140- and 40-keV images (ΔHU; ie, Hounsfield unit at 140 keV - Hounsfield unit at 40 keV) and ΔHU indexed with HUconv (ΔHU index; ie, ΔHU/HUconv × 100) were calculated. Conventional and virtual monoenergetic imaging parameters were compared between lipid-poor adenomas and nonadenomas by using the Mann-Whitney U test. Receiver operating characteristic analysis was performed to determine the sensitivity for attaining at least 95% specificity in characterizing adenomas from nonadenomas; sensitivity was compared by using the McNemar test. Results A total of 232 patients (mean age ± standard deviation, 67 years ± 11; 145 men) with 129 lipid-poor adenomas and 103 nonadenomas were evaluated. HUconv and mean attenuation on VMIs at 40-140 keV were lower and the percentage negative pixels, ΔHU, and ΔHU index higher in lipid-poor adenomas than in nonadenomas (P < .001 for all). Attenuation differences between adenomas and nonadenomas on VMIs were maximal at 40 keV (23 HU at 40 keV vs 5 HU at 140 keV). The highest sensitivities for differentiating adenomas and nonadenomas were achieved for virtual monoenergetic ΔHU index (77% [99 of 129 adenomas]), attenuation on 40-keV images (71% [91 of 129 adenomas]), and ΔHU (67% [87 of 129 adenomas]) compared to HUconv (35% [45 of 129 adenomas]) and percentage negative pixels (30% [39 of 129 adenomas]) (P < .001 for all; specificity, 95% [98 of 103 nonadenomas]). Conclusion Spectral attenuation analysis enabled differentiation of lipid-poor adenomas from nonadenomas with higher sensitivity than mean attenuation or histogram analysis of conventional CT images. © RSNA, 2021 Online supplemental material is available for this article.
Collapse
Affiliation(s)
- Yasunori Nagayama
- From the Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Chuo-ku, Kumamoto 860-8556, Japan (Y.N., T.I., S.O., S.T., T.N., O.I., T.H.); and Department of Clinical Investigation, Kumamoto University Hospital, Kumamoto, Japan (J.M.)
| | - Taihei Inoue
- From the Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Chuo-ku, Kumamoto 860-8556, Japan (Y.N., T.I., S.O., S.T., T.N., O.I., T.H.); and Department of Clinical Investigation, Kumamoto University Hospital, Kumamoto, Japan (J.M.)
| | - Seitaro Oda
- From the Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Chuo-ku, Kumamoto 860-8556, Japan (Y.N., T.I., S.O., S.T., T.N., O.I., T.H.); and Department of Clinical Investigation, Kumamoto University Hospital, Kumamoto, Japan (J.M.)
| | - Shota Tanoue
- From the Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Chuo-ku, Kumamoto 860-8556, Japan (Y.N., T.I., S.O., S.T., T.N., O.I., T.H.); and Department of Clinical Investigation, Kumamoto University Hospital, Kumamoto, Japan (J.M.)
| | - Takeshi Nakaura
- From the Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Chuo-ku, Kumamoto 860-8556, Japan (Y.N., T.I., S.O., S.T., T.N., O.I., T.H.); and Department of Clinical Investigation, Kumamoto University Hospital, Kumamoto, Japan (J.M.)
| | - Jun Morinaga
- From the Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Chuo-ku, Kumamoto 860-8556, Japan (Y.N., T.I., S.O., S.T., T.N., O.I., T.H.); and Department of Clinical Investigation, Kumamoto University Hospital, Kumamoto, Japan (J.M.)
| | - Osamu Ikeda
- From the Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Chuo-ku, Kumamoto 860-8556, Japan (Y.N., T.I., S.O., S.T., T.N., O.I., T.H.); and Department of Clinical Investigation, Kumamoto University Hospital, Kumamoto, Japan (J.M.)
| | - Toshinori Hirai
- From the Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Chuo-ku, Kumamoto 860-8556, Japan (Y.N., T.I., S.O., S.T., T.N., O.I., T.H.); and Department of Clinical Investigation, Kumamoto University Hospital, Kumamoto, Japan (J.M.)
| |
Collapse
|
16
|
Lennartz S, Parakh A, Cao J, Kambadakone A. Longitudinal reproducibility of attenuation measurements on virtual unenhanced images: multivendor dual-energy CT evaluation. Eur Radiol 2021; 31:9240-9249. [PMID: 34110426 DOI: 10.1007/s00330-021-08083-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2021] [Revised: 05/10/2021] [Accepted: 05/20/2021] [Indexed: 11/28/2022]
Abstract
OBJECTIVES The accuracy of virtual unenhanced (VUE) images has been extensively investigated, yet data on their longitudinal reproducibility is limited. The study purpose was to evaluate the longitudinal reproducibility of VUE attenuation measurements on three different dual-energy CT (DECT) scanner types. METHODS A total of 137 patients with repeated abdominal DECT either on a rapid kV switching (rsDECT; n = 46), a dual-layer detector (dlDECT; n = 43), or a dual-source scanner (dsDECT; n = 48) were retrospectively included. Attenuation was measured on VUE and corresponding contrast-enhanced images in the liver, spleen, kidneys, aorta, portal vein, and fat. Longitudinal reproducibility was evaluated by calculating the absolute inter-scan differences (HU) and the inter-scan variation (%). Measurement pairs with differences ≤ 10 HU were considered reproducible. Influence of contrast-enhanced attenuation on VUE reproducibility was analyzed using linear regression. RESULTS The scanner-specific cohorts showed similar age (p-range: 0.35-0.99), sex (p-range: 0.68-1), body weight (p-range: 0.26-0.87), body diameter (p-range: 0.34-0.76), and inter-scan time (p-range: 0.52-0.83). In total, 94.9% of VUE measurements were reproducible for rsDECT, 93.8% for dlDECT, and 90.6% for dsDECT. Overall inter-scan variation was lowest in fat (4.0 (1.7-8.2)%) and highest in tissues with high contrast enhancement: the aorta (13.3 (4.6-21.3)%), portal vein (10.8 (5.7-19.8)%), and kidneys (10.7 (3.9-18.0)%). Significant differences in inter-scan variation were found between the scanner types for the aorta, portal vein, kidneys, and spleen. Inter-scan differences in contrast-enhanced attenuation significantly influenced inter-scan differences in VUE attenuation (p < 0.001; t-ratio: 4.34). CONCLUSIONS Longitudinal reproducibility of VUE attenuation was high for all scanners, yet inter-scan variation of VUE attenuation was influenced by contrast enhancement, showing greatest magnitude and discrepancy between scanner types in vessels and the kidneys. KEY POINTS • We found that 94.9% of attenuation measurements on virtual unenhanced images were reproducible for rapid kV switching DECT, 93.8% for dual-layer detector DECT, and 90.6% for dual-source DECT. • Inter-scan variation of attenuation in virtual unenhanced images was comparable between the three scanner types in the liver and fat, whereas inter-scan variation in the spleen, kidneys, portal vein, and aorta showed significant differences between scanner types (p < 0.05). • Inter-scan attenuation differences in contrast-enhanced images significantly influenced inter-scan differences in virtual unenhanced attenuation (p < 0.001, t-ratio: 4.34), suggesting a residual impact of contrast enhancement differences between examinations.
Collapse
Affiliation(s)
- Simon Lennartz
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, White 270, Boston, MA, 02114-2696, USA.,Institute for Diagnostic and Interventional Radiology, Faculty of Medicine, University Cologne and University Hospital Cologne, Kerpener Straße 62, 50937, Cologne, Germany
| | - Anushri Parakh
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, White 270, Boston, MA, 02114-2696, USA
| | - Jinjin Cao
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, White 270, Boston, MA, 02114-2696, USA
| | - Avinash Kambadakone
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, White 270, Boston, MA, 02114-2696, USA.
| |
Collapse
|
17
|
Abstract
Incidentally detected adrenal nodules are common, and prevalence increases with patient age. Although most are benign, it is important for the radiologist to be able to accurately determine which nodules require further testing and which are safely left alone. The American College of Radiology incidental adrenal White Paper provides a structured algorithm based on expert consensus for management of incidental adrenal nodules. If further diagnostic testing is indicated, adrenal computed tomography is the most appropriate test in patients for nodules less than 4 cm. In addition to imaging, biochemical testing and endocrinology referral is warranted to exclude a functioning mass.
Collapse
Affiliation(s)
- Daniel I Glazer
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, 75 Francis Street, Boston, MA 02115, USA.
| | - Michael T Corwin
- Department of Radiology, University of California, Davis, 4860 Y Street, Suite 3100, Sacramento, CA 95817, USA
| | - William W Mayo-Smith
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, 75 Francis Street, Boston, MA 02115, USA
| |
Collapse
|
18
|
Estimating dual-energy CT imaging from single-energy CT data with material decomposition convolutional neural network. Med Image Anal 2021; 70:102001. [PMID: 33640721 DOI: 10.1016/j.media.2021.102001] [Citation(s) in RCA: 28] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2020] [Revised: 02/06/2021] [Accepted: 02/11/2021] [Indexed: 01/12/2023]
Abstract
Dual-energy computed tomography (DECT) is of great significance for clinical practice due to its huge potential to provide material-specific information. However, DECT scanners are usually more expensive than standard single-energy CT (SECT) scanners and thus are less accessible to undeveloped regions. In this paper, we show that the energy-domain correlation and anatomical consistency between standard DECT images can be harnessed by a deep learning model to provide high-performance DECT imaging from fully-sampled low-energy data together with single-view high-energy data. We demonstrate the feasibility of the approach with two independent cohorts (the first cohort including contrast-enhanced DECT scans of 5753 image slices from 22 patients and the second cohort including spectral CT scans without contrast injection of 2463 image slices from other 22 patients) and show its superior performance on DECT applications. The deep-learning-based approach could be useful to further significantly reduce the radiation dose of current premium DECT scanners and has the potential to simplify the hardware of DECT imaging systems and to enable DECT imaging using standard SECT scanners.
Collapse
|
19
|
Virtual Noncontrast Images From Portal Venous Phase Spectral-Detector CT Acquisitions for Adrenal Lesion Characterization. J Comput Assist Tomogr 2021; 45:24-28. [PMID: 32168080 DOI: 10.1097/rct.0000000000000982] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
OBJECTIVE The aim of this study was to investigate if Hounsfield unit (HU) values from virtual noncontrast (VNC) images derived from portal venous phase spectral-detector computed tomography can help to differentiate adrenal adenomas and metastases. METHODS Spectral-detector computed tomography datasets of 33 patients with presence of adrenal lesions and standard of reference for lesion origin by follow-up/prior examinations or dedicated magnetic resonance imaging were included. Conventional and VNC images were reconstructed from the same scan. Region of interest-based image analysis was performed in adrenal lesions and contralateral healthy adrenal tissue. RESULTS The 33 lesions consisted of 23 adenomas and 10 metastases. Hounsfield unit values of all lesions in VNC images were significantly lower compared with conventional images (18.2 ± 12.6 HU vs 59.6 ± 21.7 HU, P < 0.001). Hounsfield unit values in adenomas were significantly lower in VNC images (11.3 ± 6.5 HU vs 34.1 ± 9.1 HU, P < 0.001). CONCLUSIONS Virtual noncontrast HU values differed significantly between adrenal adenomas and metastases and can therefore be used for improved characterization of incidental adrenal lesions and definition of adrenal adenomas.
Collapse
|
20
|
Accuracy of Dual-Energy CT Virtual Unenhanced and Material-Specific Images: A Phantom Study. AJR Am J Roentgenol 2020; 215:1146-1154. [DOI: 10.2214/ajr.19.22372] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
21
|
Tu W, Abreu-Gomez J, Udare A, Alrashed A, Schieda N. Utility of T2-weighted MRI to Differentiate Adrenal Metastases from Lipid-Poor Adrenal Adenomas. Radiol Imaging Cancer 2020; 2:e200011. [PMID: 33778748 DOI: 10.1148/rycan.2020200011] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2020] [Revised: 06/26/2020] [Accepted: 06/30/2020] [Indexed: 12/17/2022]
Abstract
Purpose To evaluate T2-weighted MRI features to differentiate adrenal metastases from lipid-poor adenomas. Materials and Methods With institutional review board approval, this study retrospectively compared 40 consecutive patients (mean age, 66 years ± 10 [standard deviation]) with metastases to 23 patients (mean age, 60 years ± 15) with lipid-poor adenomas at 1.5- and 3-T MRI between June 2016 and March 2019. A blinded radiologist measured T2-weighted signal intensity (SI) ratio (SInodule/SIpsoas muscle), T2-weighted histogram features, and chemical shift SI index. Two blinded radiologists (radiologist 1 and radiologist 2) assessed T2-weighted SI and T2-weighted heterogeneity using five-point Likert scales. Results Subjectively, T2-weighted SI (P < .001 for radiologist 1 and radiologist 2) and T2-weighted heterogeneity (P < .001, for radiologist 1 and radiologist 2) were higher in metastases compared with adenomas when assessed by both radiologists. Agreement between the radiologists was substantial for T2-weighted SI (Cohen κ = 0.67) and T2-weighted heterogeneity (κ = 0.62). Metastases had higher T2-weighted SI ratio than adenomas (3.6 ± 1.7 [95% confidence interval {CI}: 0.2, 8.2] vs 2.2 ± 1.0 [95% CI: 0.6, 4.3], P < .001) and higher T2-weighted entropy (6.6 ± 0.6 [95% CI: 4.9, 7.5] vs 5.0 ± 0.8 [95% CI: 3.5, 6.6], P < .001). At multivariate analysis, T2-weighted entropy was the best differentiating feature (P < .001). Chemical shift SI index did not differ between metastases and adenomas (P = .748). Area under the receiver operating characteristic curve (AUC) for T2-weighted SI ratio and T2-weighted entropy were 0.76 (95% CI: 0.64, 0.88) and 0.94 (95% CI: 0.88, 0.99). The logistic regression model combining T2-weighted SI ratio with T2-weighted entropy yielded AUC of 0.95 (95% CI: 0.91, 0.99) and did not differ compared with T2-weighted entropy alone (P = .268). There was no difference in logistic regression model accuracy comparing the data by either field strength, 1.5- or 3-T MRI (P > .05). Conclusion Logistic regression models combining T2-weighted SI and T2-weighted heterogeneity can differentiate metastases from lipid-poor adenomas. Validation of these preliminary results is required.Keywords: Adrenal, MR-Imaging, UrinarySupplemental material is available for this article.© RSNA, 2020.
Collapse
Affiliation(s)
- Wendy Tu
- Department of Medical Imaging, The Ottawa Hospital, University of Ottawa, 1053 Carling Ave, C1 Radiology, Ottawa, ON, Canada K1Y 4E9 (W.T., J.A.G., A.U., N.S.); and Department of Radiology and Medical Imaging, King Saud University Medical City, King Khalid University Hospital, Riyadh, Saudi Arabia (A.A.)
| | - Jorge Abreu-Gomez
- Department of Medical Imaging, The Ottawa Hospital, University of Ottawa, 1053 Carling Ave, C1 Radiology, Ottawa, ON, Canada K1Y 4E9 (W.T., J.A.G., A.U., N.S.); and Department of Radiology and Medical Imaging, King Saud University Medical City, King Khalid University Hospital, Riyadh, Saudi Arabia (A.A.)
| | - Amar Udare
- Department of Medical Imaging, The Ottawa Hospital, University of Ottawa, 1053 Carling Ave, C1 Radiology, Ottawa, ON, Canada K1Y 4E9 (W.T., J.A.G., A.U., N.S.); and Department of Radiology and Medical Imaging, King Saud University Medical City, King Khalid University Hospital, Riyadh, Saudi Arabia (A.A.)
| | - Abdulmohsen Alrashed
- Department of Medical Imaging, The Ottawa Hospital, University of Ottawa, 1053 Carling Ave, C1 Radiology, Ottawa, ON, Canada K1Y 4E9 (W.T., J.A.G., A.U., N.S.); and Department of Radiology and Medical Imaging, King Saud University Medical City, King Khalid University Hospital, Riyadh, Saudi Arabia (A.A.)
| | - Nicola Schieda
- Department of Medical Imaging, The Ottawa Hospital, University of Ottawa, 1053 Carling Ave, C1 Radiology, Ottawa, ON, Canada K1Y 4E9 (W.T., J.A.G., A.U., N.S.); and Department of Radiology and Medical Imaging, King Saud University Medical City, King Khalid University Hospital, Riyadh, Saudi Arabia (A.A.)
| |
Collapse
|
22
|
Rajiah P, Parakh A, Kay F, Baruah D, Kambadakone AR, Leng S. Update on Multienergy CT: Physics, Principles, and Applications. Radiographics 2020; 40:1284-1308. [DOI: 10.1148/rg.2020200038] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Affiliation(s)
- Prabhakar Rajiah
- From the Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (P.R., S.L.); Department of Radiology, Massachusetts General Hospital, Boston, Mass (A.P., A.R.K.); Department of Radiology, UT Southwestern Medical Center, Dallas, Tex (F.K.); and Department of Radiology, Medical University of South Carolina, Charleston, SC (D.B.)
| | - Anushri Parakh
- From the Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (P.R., S.L.); Department of Radiology, Massachusetts General Hospital, Boston, Mass (A.P., A.R.K.); Department of Radiology, UT Southwestern Medical Center, Dallas, Tex (F.K.); and Department of Radiology, Medical University of South Carolina, Charleston, SC (D.B.)
| | - Fernando Kay
- From the Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (P.R., S.L.); Department of Radiology, Massachusetts General Hospital, Boston, Mass (A.P., A.R.K.); Department of Radiology, UT Southwestern Medical Center, Dallas, Tex (F.K.); and Department of Radiology, Medical University of South Carolina, Charleston, SC (D.B.)
| | - Dhiraj Baruah
- From the Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (P.R., S.L.); Department of Radiology, Massachusetts General Hospital, Boston, Mass (A.P., A.R.K.); Department of Radiology, UT Southwestern Medical Center, Dallas, Tex (F.K.); and Department of Radiology, Medical University of South Carolina, Charleston, SC (D.B.)
| | - Avinash R. Kambadakone
- From the Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (P.R., S.L.); Department of Radiology, Massachusetts General Hospital, Boston, Mass (A.P., A.R.K.); Department of Radiology, UT Southwestern Medical Center, Dallas, Tex (F.K.); and Department of Radiology, Medical University of South Carolina, Charleston, SC (D.B.)
| | - Shuai Leng
- From the Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (P.R., S.L.); Department of Radiology, Massachusetts General Hospital, Boston, Mass (A.P., A.R.K.); Department of Radiology, UT Southwestern Medical Center, Dallas, Tex (F.K.); and Department of Radiology, Medical University of South Carolina, Charleston, SC (D.B.)
| |
Collapse
|
23
|
Nagayama Y, Inoue T, Oda S, Tanoue S, Nakaura T, Ikeda O, Yamashita Y. Adrenal Adenomas versus Metastases: Diagnostic Performance of Dual-Energy Spectral CT Virtual Noncontrast Imaging and Iodine Maps. Radiology 2020; 296:324-332. [PMID: 32452733 DOI: 10.1148/radiol.2020192227] [Citation(s) in RCA: 56] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Background Dual-energy CT allows virtual noncontrast (VNC) attenuation and iodine density measurements from contrast material-enhanced examination, potentially enabling adrenal lesion characterization. However, data regarding diagnostic performance remain limited, and combined diagnostic values have never been investigated. Purpose To determine whether VNC attenuation, iodine density, and combination of the two allow reliable differentiation between adrenal adenomas and metastases. Materials and Methods This retrospective study included patients with adrenal lesions who underwent unenhanced and portal venous phase dual-energy CT between January 2017 and December 2018. Unenhanced, contrast-enhanced, and VNC attenuation, as well as iodine density, were measured for each lesion. Agreement between unenhanced and VNC attenuation was assessed by using Wilcoxon rank-sum test, Pearson correlation coefficient, and Bland-Altman plot. The ratio of iodine density to VNC attenuation was calculated for lesions with positive VNC attenuation. Each parameter was compared between adenomas and metastases; diagnostic performance was evaluated by using the area under the receiver operating characteristic curve (AUC) with sensitivity and specificity. Results A total of 149 patients (mean age, 65 years ± 13 [standard deviation]; 89 men; 98 patients with 104 adenomas; 51 patients with 56 metastases) were evaluated. VNC attenuation showed strong positive correlation with unenhanced attenuation (r = 0.92) but resulted in overestimates of adenoma attenuation (mean bias, +11 HU; P < .001) and was less sensitive (P = .03) in the diagnosis of adenomas compared with unenhanced attenuation (sensitivity of 79% [81 of 102] [95% confidence interval {CI}: 70%, 87%] and specificity of 95% [53 of 56] [95% CI: 85%, 99%] versus sensitivity of 85% [87 of 102] [95% CI: 77%, 92%] and specificity of 96% [54 of 56] [95% CI: 88%, 100%], with thresholds of ≤29 HU and ≤22 HU, respectively). Contrast-enhanced attenuation had no discriminatory ability (AUC, 0.54; 95% CI: 0.45, 0.62). Iodine density yielded moderate performance (sensitivity of 78% [80 of 102] [95% CI: 69%, 86%] and specificity of 71% [40 of 56] [95% CI: 58%, 83%], with a threshold of ≥1.82 mg/mL). The iodine-to-VNC ratio was higher in adenomas than in metastases (mean, 14.5 vs 4.6; P < .001), with sensitivity of 95% (97 of 102; 95% CI: 89%, 98%) and specificity of 95% (53 of 56; 95% CI: 85%, 99%), with a threshold of 6.7 or greater. Conclusion Contrast-enhanced dual-energy CT during the portal venous phase enabled accurate differentiation between adrenal adenomas and metastases by combining virtual noncontrast attenuation and iodine density. Virtual noncontrast imaging alone led to overestimates of adenoma attenuation, and iodine density alone had limited discriminatory utility. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Hindman and Megibow in this issue.
Collapse
Affiliation(s)
- Yasunori Nagayama
- From the Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1 Honjo, Chuo-ku, Kumamoto 860-8556, Japan
| | - Taihei Inoue
- From the Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1 Honjo, Chuo-ku, Kumamoto 860-8556, Japan
| | - Seitaro Oda
- From the Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1 Honjo, Chuo-ku, Kumamoto 860-8556, Japan
| | - Shota Tanoue
- From the Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1 Honjo, Chuo-ku, Kumamoto 860-8556, Japan
| | - Takeshi Nakaura
- From the Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1 Honjo, Chuo-ku, Kumamoto 860-8556, Japan
| | - Osamu Ikeda
- From the Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1 Honjo, Chuo-ku, Kumamoto 860-8556, Japan
| | - Yasuyuki Yamashita
- From the Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1 Honjo, Chuo-ku, Kumamoto 860-8556, Japan
| |
Collapse
|
24
|
Abstract
OBJECTIVE To review the current evidence and guidelines for diagnosis and management of incidental adrenal masses with a focus on the recent changes made by the American College of Radiology (ACR) Incidental Findings Committee. CONCLUSION Incidentally detected adrenal nodules are a commonly encountered finding estimated to occur in 5-7% of the adult population. By following current recommendations, radiologists can improve patient care by efficiently determining which masses require further diagnostic testing and which masses can be considered benign and not require further follow-up.
Collapse
Affiliation(s)
- Daniel I Glazer
- Division of Abdominal Imaging and Intervention, Department of Radiology, Harvard Medical School, Brigham and Women's Hospital, 75 Francis Street, Boston, MA, 02115, USA.
| | - William W Mayo-Smith
- Division of Abdominal Imaging and Intervention, Department of Radiology, Harvard Medical School, Brigham and Women's Hospital, 1620 Tremont Street, Boston, MA, 02120, USA
| |
Collapse
|
25
|
Impact of Patient Size and Radiation Dose on Accuracy and Precision of Iodine Quantification and Virtual Noncontrast Values in Dual-layer Detector CT-A Phantom Study. Acad Radiol 2020; 27:409-420. [PMID: 30987872 DOI: 10.1016/j.acra.2019.02.013] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2018] [Revised: 01/26/2019] [Accepted: 02/08/2019] [Indexed: 12/14/2022]
Abstract
RATIONALE AND OBJECTIVES Iodine quantification (IQ) and virtual noncontrast (VNC) images produced by dual-energy CT (DECT) can be used for various clinical applications. We investigate the performance of dual-layer DECT (DLDECT) in different phantom sizes and varying radiation doses and tube voltages, including a low-dose pediatric setting. MATERIALS AND METHODS Three phantom sizes (simulating a 10-year-old child, an average, and a large-sized adult) were scanned with iodine solution inserts with concentrations ranging 0-32 mg/ml, using the DLDECT. Each phantom size was scanned with CTDIvol 2-15 mGy at 120 and 140 kVp. The smallest phantom underwent additional scans with CTDIvol 0.9-1.8 mGy. All scans were repeated 3 times. Each iodine insert was analyzed using VNC and IQ images for accuracy and precision, by comparison to known values. RESULTS For scans from 2 to 15 mGy mean VNC attenuation and IQ error in the iodine inserts in the small, medium, and large phantoms was 1.2 HU ± 3.2, -1.2 HU ± 14.9, 2.6 HU ± 23.6; and +0.1 mg/cc ± 0.4, -0.9 mg/cc ± 0.9, and -1.8 mg/cc ± 1.8, respectively. In this dose range, there were no significant differences (p ≥ 0.05) in mean VNC attenuation or IQ accuracy in each phantom size, while IQ was significantly less precise in the small phantom at 2 mGy and 10 mGy (p < 0.05). Scans with CTDIvol 0.9-1.8 mGy in the small phantom showed a limited, but statistically significantly lower VNC attenuation precision and IQ accuracy (-0.5 HU ± 5.3 and -0.3 mg/cc ± 0.5, respectively) compared to higher dose scans in the same phantom size. CONCLUSION Performance of iodine quantification and subtraction by VNC images in DLDECT is largely dose independent, with the primary factor being patient size. Low-dose pediatric scan protocols have a significant, but limited impact on IQ and VNC attenuation values.
Collapse
|
26
|
Utility of Iodine Density Perfusion Maps From Dual-Energy Spectral Detector CT in Evaluating Cardiothoracic Conditions: A Primer for the Radiologist. AJR Am J Roentgenol 2020; 214:775-785. [PMID: 32045305 DOI: 10.2214/ajr.19.21818] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
OBJECTIVE. The purpose of this article is to outline the utility of iodine density maps for evaluating cardiothoracic disease and abnormalities. Multiple studies have shown that the variety of images generated from dual-energy spectral detector CT (SDCT) improve identification of cardiothoracic conditions. CONCLUSION. Understanding the technique of SDCT and being familiar with the features of different cardiothoracic conditions on iodine density map images help the radiologist make a better diagnosis.
Collapse
|
27
|
Wortman JR, Shyu JY, Dileo J, Uyeda JW, Sodickson AD. Dual-energy CT for routine imaging of the abdomen and pelvis: radiation dose and image quality. Emerg Radiol 2019; 27:45-50. [PMID: 31673838 DOI: 10.1007/s10140-019-01733-9] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2019] [Revised: 09/18/2019] [Accepted: 09/24/2019] [Indexed: 11/28/2022]
Abstract
PURPOSE To assess the radiation dose and image quality of routine dual energy CT (DECT) of the abdomen and pelvis performed in the emergency department setting, compared with single energy CT (SECT). MATERIALS AND METHODS Seventy-five consecutive routine contrast-enhanced SECT scans of the abdomen and pelvis meeting inclusion criteria were compared with 75 routine contrast-enhanced DECT scans matched by size and patient weight (within 10 lbs), performed on the same dual-source DECT scanner. Cohorts were compared in terms of radiation dose metrics of CT dose index (CTDIvol) and dose length product (DLP), objective measurements of image quality (signal, noise, and signal-to-noise ratio of a variety of anatomical landmarks), and subjective measurements of image quality scored by two emergency radiologists. RESULTS Demographics and patient size were not statistically different between DECT and SECT cohorts. Both average scans CTDIvol and DLP were significantly lower with DECT than with SECT. Average scan CTDIvol for SECT was 14.7 mGy (± 6.6) and for DECT was 10.9 mGy (± 3.8) (p < 0.0001). Average scan DLP for SECT was 681.5 mGy cm (± 339.3) and for DECT was 534.8 mGy cm (± 201.9) (p < 0.0001). For objective image quality metrics, for all structures measured, noise was significantly lower and SNR was significantly higher with DECT compared with SECT. For subjective image quality, for both readers, there was no significant difference between SECT and DECT in subjective image quality for soft tissues and vascular structures, or for subjective image noise. CONCLUSIONS DECT was performed with decreased radiation dose when compared with SECT, demonstrated improved objective measurements of image quality, and equivalent subjective image quality.
Collapse
Affiliation(s)
- Jeremy R Wortman
- Department of Radiology, Section of Emergency Radiology, Brigham and Women's Hospital, 75 Francis Street, Boston, MA, 02115, USA. .,Harvard Medical School, Boston, MA, USA. .,Lahey Hospital and Medical Center, Burlington, MA, USA.
| | - Jeffrey Y Shyu
- Department of Radiology, Section of Emergency Radiology, Brigham and Women's Hospital, 75 Francis Street, Boston, MA, 02115, USA.,Harvard Medical School, Boston, MA, USA
| | - Jeffrey Dileo
- Department of Radiology, Section of Emergency Radiology, Brigham and Women's Hospital, 75 Francis Street, Boston, MA, 02115, USA.,Harvard Medical School, Boston, MA, USA
| | - Jennifer W Uyeda
- Department of Radiology, Section of Emergency Radiology, Brigham and Women's Hospital, 75 Francis Street, Boston, MA, 02115, USA.,Harvard Medical School, Boston, MA, USA
| | - Aaron D Sodickson
- Department of Radiology, Section of Emergency Radiology, Brigham and Women's Hospital, 75 Francis Street, Boston, MA, 02115, USA.,Harvard Medical School, Boston, MA, USA
| |
Collapse
|
28
|
Taylor RE, Mager P, Yu NC, Katz DP, Brady JR, Gupta N. Iodine quantification and detectability thresholds among major dual-energy CT platforms. Br J Radiol 2019; 92:20190530. [PMID: 31559858 DOI: 10.1259/bjr.20190530] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022] Open
Abstract
OBJECTIVES To estimate the minimum detectable iodine concentration on multiple dual-energy CT (DECT) platforms. METHODS AND MATERIALS A phantom containing iodine concentrations ranging from 0 to 10 mg ml-1 was scanned with five dual-energy platforms (two rapid kilo volt switching (r-kVs), one dual source (DS), one sequential acquisition and one split-filter). Serial dilutions of 300 mg ml-1 iodinated contrast material were used to generate concentrations below 2 mg ml-1. Iodine density and virtual monoenergetic images were reviewed by three radiologists to determine the minimum visually detectable iodine concentration. Contrast-to-noise ratios (CNRs) were calculated. RESULTS 1 mg mL-1 (~0.8 mg mL-1 corrected) was the minimum visually detectable concentration among the platforms and could be seen by all readers on the third-generation r-kVs and DS platforms. CONCLUSIONS At low concentrations, CNR for monoenergetic images was highest on the DS platform and lowest in the sequential acquisition and split-filter platforms. ADVANCES IN KNOWLEDGE The results of this study corroborate previous in vivo estimates of iodine detection limits at DECT and provide a comparison for the performance of different DECT platforms at low iodine concentrations in vitro.
Collapse
Affiliation(s)
| | - Pamela Mager
- Department of Radiology, Houston Methodist Hospital, Houston, TX
| | - Nam C Yu
- Department of Radiology, Houston Methodist Hospital, Houston, TX
| | - David P Katz
- Department of Radiology, Houston Methodist Hospital, Houston, TX
| | - Jett R Brady
- Department of Radiology, Houston Methodist Hospital, Houston, TX
| | - Nakul Gupta
- Department of Radiology, Houston Methodist Hospital, Houston, TX
| |
Collapse
|
29
|
Interscanner and Intrascanner Comparison of Virtual Unenhanced Attenuation Values Derived From Twin Beam Dual-Energy and Dual-Source, Dual-Energy Computed Tomography. Invest Radiol 2019; 54:1-6. [PMID: 30096063 DOI: 10.1097/rli.0000000000000501] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE The aim of the current study was to evaluate the reliability and comparability of virtual unenhanced (VUE) attenuation values derived from scans of a single-source, dual-energy computed tomography using a split-filter (tbDECT) to a dual-source dual-energy CT (dsDECT). MATERIALS AND METHODS In this retrospective study, comparisons for tbDECT and dsDECT were made within and between different dual-energy platforms. For the interscanner comparison, 126 patients were scanned with both scanners within a time interval of 224 ± 180 days; for the intrascanner comparison, another 90 patients were scanned twice with the same scanner within a time interval of 136 ± 140 days. Virtual unenhanced images were processed off of venous phase series. Attenuation values of 7 different tissues were recorded. Disagreement for VUE HU measurements greater than 10 HU between 2 scans was defined as inadequate. RESULTS The interscanner analysis showed significant difference between tbDE and dsDE VUE CT values (P < 0.01) for 6 of 7 organs. Percentage of cases that had more than 10 HU difference between tbDE and dsDE for an individual patient ranged between 15% (left kidney) and 62% (spleen).The intrascanner analysis showed no significant difference between repeat scans for both tbDECT and dsDECT (P > 0.05). However, intrascanner disagreements for the VUE HU measurements greater than 10 HU were recorded in 10% of patients scanned on the tbDECT and 0% of patients scanned on the dsDECT. The organs with the highest portion of greater than 10 HU errors were the liver and the aorta (both 20%). CONCLUSIONS Dual-energy techniques vary in reproducibility of VUE attenuation values. In the current study, tbDECT demonstrated higher variation in VUE HU measurements in comparison to a dsDECT. Virtual unenhanced HU measurements cannot be reliably compared on follow-up CT, if these 2 different dual-energy CT platforms are used.
Collapse
|
30
|
Clinical and Payer-Based Analysis of Value of Dual-Energy Computed Tomography for Workup of Incidental Abdominal Findings. J Comput Assist Tomogr 2019; 43:605-611. [PMID: 31162230 DOI: 10.1097/rct.0000000000000886] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
OBJECTIVE To perform a clinical and payer-based analysis of the value of dual-energy computed tomography (DECT) for workup of incidental abdominal findings. METHODS This was a single-center, retrospectively designed, Health Insurance Portability and Accountability Act-compliant study approved by our institutional review board. Sixty-nine examinations in 69 patients (45 men, 24 women; mean age, 57.7 years) who underwent single-phase postcontrast abdominal DECT studies between January 1, 2011, and December 31, 2017, were included. Two radiologists, blinded to study objective and design, reviewed all cases and identified incidental abdominal findings needing further imaging. All incidental findings were reviewed by 2 other investigators, who determined whether an imaging-based diagnosis could be made using DECT virtual noncontrast images and iodine maps. Additional studies and associated payer-reimbursement amounts avoided by use of DECT were estimated. All imaging costs were estimated based on the US Centers for Medicare & Medicaid Services reimbursement amounts. RESULTS Thirty-four incidental findings (renal mass, n = 20; adrenal nodule, n = 8; pancreatic cystic lesions, n = 3; others, n = 3) were identified in 19 (27.5%) of 69 patients. Dual-energy computed tomography characterized 27 incidental findings in 15 patients and accounted for cost savings of 15 additional imaging examinations (abdominal magnetic resonance imaging, n = 11; abdominal computed tomography, n = 4). Based on Centers for Medicare & Medicaid Services reimbursement amounts, we estimated that, by abolishing the need for additional imaging use, DECT saved US $84.95 per patient. CONCLUSIONS Dual-energy computed tomography can provide an imaging-based diagnosis of incidental abdominal findings, otherwise incompletely characterized on routine abdominal computed tomography, in approximately 21% of patients. In select patients, the monetary savings from abolishing additional imaging may reduce payer costs associated with use of DECT.
Collapse
|
31
|
Meyer M, Nelson RC, Vernuccio F, González F, Farjat AE, Patel BN, Samei E, Henzler T, Schoenberg SO, Marin D. Virtual Unenhanced Images at Dual-Energy CT: Influence on Renal Lesion Characterization. Radiology 2019; 291:381-390. [DOI: 10.1148/radiol.2019181100] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
|
32
|
Çamlıdağ İ, Nural MS, Danacı M, Özden E. Usefulness of rapid kV-switching dual energy CT in renal tumor characterization. Abdom Radiol (NY) 2019; 44:1841-1849. [PMID: 30637472 DOI: 10.1007/s00261-019-01897-5] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
PURPOSE To investigate whether iodine content can discriminate between benign or malignant renal tumors, malign tumor subtypes, low-grade and high-grade tumors on rapid kv-switching dual-energy CT (rsDECT). METHODS This prospective study enrolled 95 patients with renal tumors who underwent rsDECT for tumor characterization between 2016 and 2018. Attenuation on true and virtual unenhanced images, absolute enhancement and enhancement ratio and iodine content of each lesion on nephrographic phase iodine density images were measured. Histopathological diagnosis was obtained following either surgery or core biopsy. RESULTS Eighty-five tumors were renal cell carcinoma (RCC) (56 clear cell, 20 papillary, 9 chromophobe) and 10 were benign (6 angiomyolipoma,4 oncocytoma). 46 tumors were low-grade and 23 high-grade. There was significant difference between iodine content of clear cell and non-clear cell (papillary + chromophobe) RCC (p < 0.001). However, no significant iodine content differences were found between papillary and chromophobe RCC, benign and malignant tumors, low-grade and high-grade tumors. The best cut-off iodine content for differentiating clear cell from non-clear cell RCC was 3.2 mg/ml and clear cell from papillary RCC was 2.9 mg/ml with a high sensitivity and specificity. Also, significant difference was found between attenuation values of true and virtual unenhanced images (p = 0.007). Mean iodine content, absolute enhancement and enhancement ratio were highly correlated. CONCLUSION rsDECT contributes to renal tumor characterization by showing higher iodine content in clear cell RCCs compared with non-clear cell RCCs.
Collapse
|
33
|
Spectral CT and its specific values in the staging of patients with non-small cell lung cancer: technical possibilities and clinical impact. Clin Radiol 2019; 74:456-466. [PMID: 30905380 DOI: 10.1016/j.crad.2019.02.010] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2018] [Accepted: 02/12/2019] [Indexed: 12/25/2022]
Abstract
AIM To investigate how spectral computed tomography (SCT) values impact the staging of non-small cell lung cancer (NSCLC) patients. MATERIALS AND METHODS One hundred and thirteen patients with confirmed NSCLC were included in a prospective cohort study. All patients underwent single-phase contrast-enhanced SCT (using the fast tube voltage switching technique, 80-140 kV). SCT values (iodine content [IC], spectral slope pitch, and radiodensity increase) of malignant tissue (primary and metastases) and lymph nodes (LNs) were measured. Adrenal masses were evaluated in a virtual non-contrast series (VNS). If pulmonary embolism was present, pulmonary perfusion was analysed as an additional finding. RESULTS Fifty-two untreated primary NSCLC lesions were evaluable. Lung adenocarcinoma had significantly higher normalised IC (NIC: 19.37) than squamous cell carcinoma (NIC: 12.03; p=0.035). Pulmonary metastases were not significantly different from benign lung nodules. A total of 126 LNs were analysed and histologically proven metastatic LNs (2.08 mg/ml) had significantly lower IC than benign LNs (2.58 mg/ml; p=0.023). Among 34 adrenal masses, VNS identified adenomas with high sensitivity (91%) and specificity (100%). In two patients, a perfusion defect due to pulmonary embolism was detected in the iodine images. CONCLUSION SCT may contribute to the differentiation of histological NSCLC subtypes and improve the identification of LN metastases. VNS differentiates adrenal adenoma from metastasis. In case of pulmonary embolism, iodine imaging can visualise associated pulmonary perfusion defects.
Collapse
|
34
|
Dual energy CT for evaluation of polycystic kidneys: a multi reader study of interpretation time and diagnostic confidence. Abdom Radiol (NY) 2018; 43:3418-3424. [PMID: 29926138 DOI: 10.1007/s00261-018-1674-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
Abstract
PURPOSE To compare dual-energy CT (DECT) iodine overlay images with renal mass protocol CT in the evaluation of polycystic kidneys with respect to reading time, diagnostic confidence, and detection of renal lesions that are not definitively benign. METHODS Following IRB approval, portal venous phase dual-source DECT scans performed between September 2013 and February 2016 from 55 patients (mean age 67 ± 15 years, 31 male, 24 female) with polycystic kidneys (4 or more cysts) were included. For each patient, two image sets were created: (1) DECT post-processed iodine overlay images and (2) simulated renal mass protocol CT images (virtual noncontrast and mixed images). Two radiologists independently retrospectively reviewed both sets at separate time points, evaluating for the presence of lesions that were not definitively benign (enhancing lesions or Bosniak IIF cysts), as well as reading times and Likert scale diagnostic confidence ratings (scaled 1-5) for the presence of non-benign lesions. Reading times were compared with a t test, diagnostic confidence with a McNemar test, and lesion number detection with Cohen's kappa test. RESULTS Iodine overlay images were read faster (mean 55 ± 26 s) than renal mass protocol (mean 105 ± 51 s) (p < 0.001). Readers assigned the highest diagnostic confidence rating in 64% using iodine overlay series, compared to 17% using renal mass protocol (p < 0.0001). The proportion of patients with recorded lesions was not significantly different between methods (p = 0.62). CONCLUSIONS DECT improves lesion assessment in polycystic kidneys by decreasing reading times and increasing diagnostic confidence, without affecting lesion detection rates.
Collapse
|
35
|
Yang L, Li Y, Shi GF, Zhou T, Tan BB. The Concentration of Iodine in Perigastric Adipose Tissue: A Novel Index for the Assessment of Serosal Invasion in Patients with Gastric Cancer after Neoadjuvant Chemotherapy. Digestion 2018; 98:87-94. [PMID: 29698943 DOI: 10.1159/000487709] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/27/2017] [Accepted: 02/04/2018] [Indexed: 02/04/2023]
Abstract
OBJECTIVE This study aims to explore the association between iodine concentration (IC) in perigastric adipose tissue (PAT), quantified by dual-energy computed tomography (DECT) and serosal invasion (SI) in patients with gastric cancer post-neoadjuvant chemotherapy (NAC). METHODS Forty-three patients with T4-staged gastric cancer were enrolled. IC and standardized IC in PAT (ICPAT and SICPAT) were quantified by DECT pre and post NAC. A postoperative pathologic examination was performed to stage gastric cancer. RESULTS After NAC, a total of 43 participants were assigned to group A with 13 patients and group B with 30 patients according to the results of the postoperative pathologic examination. The accuracy of conventional CT in identifying SI was 74.42%. Differences of variations between pre- and post- NAC ICPAT, SICPAT, ∆ICPAT, and ∆SICPAT were observed respectively (p < 0.05). Intragroup ICPAT and SICPAT also changed significantly after NAC (p < 0.05). The area under the ROC curve was 0.929, with the threshold of ∆SICPAT reaching 0.095. The sensitivity, specificity, and accuracy of SICPAT in identifying post-NAC SI were 92.30, 86.70, and 88.37% respectively. Moreover, the 2 measurements in the same patient maintain a high level of consistency. CONCLUSION These results showed that SICPAT is a reliable index for identifying post-NAC SI.
Collapse
Affiliation(s)
- Li Yang
- Department of CT, The Fourth Hospital of Hebei Medical University, Shijiazhuang, China
| | - Yong Li
- Department of General Surgery, The Fourth Hospital of Hebei Medical University, Shijiazhuang, China
| | - Gao-Feng Shi
- Department of CT, The Fourth Hospital of Hebei Medical University, Shijiazhuang, China
| | - Tao Zhou
- Department of General Surgery, The Fourth Hospital of Hebei Medical University, Shijiazhuang, China
| | - Bi-Bo Tan
- Department of General Surgery, The Fourth Hospital of Hebei Medical University, Shijiazhuang, China
| |
Collapse
|
36
|
Wortman JR, Sodickson AD. Pearls, Pitfalls, and Problems in Dual-Energy Computed Tomography Imaging of the Body. Radiol Clin North Am 2018; 56:625-640. [PMID: 29936951 DOI: 10.1016/j.rcl.2018.03.007] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
Dual-energy computed tomography (DECT) is an exciting technology that is increasing in routine use and has the potential for significant clinical impact. With the advancement of DECT, it is important for radiologists to be aware of potential challenges with DECT acquisition and postprocessing, and to have a basic knowledge of unique artifacts and diagnostic pitfalls that can occur when interpreting DECT scans and DECT postprocessed images. This article serves as a practical overview of potential problems and diagnostic pitfalls associated with DECT, and steps that can be taken to avoid them.
Collapse
Affiliation(s)
- Jeremy R Wortman
- Division of Emergency Radiology, Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, 75 Francis Street, Boston, MA 02115, USA.
| | - Aaron D Sodickson
- Division of Emergency Radiology, Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, 75 Francis Street, Boston, MA 02115, USA
| |
Collapse
|
37
|
Morgan DE. The Role of Dual-Energy Computed Tomography in Assessment of Abdominal Oncology and Beyond. Radiol Clin North Am 2018; 56:565-585. [PMID: 29936948 DOI: 10.1016/j.rcl.2018.03.005] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
The added value and strength of dual energy computed tomography for the evaluation of oncologic patients revolve around the use of lower energy reconstructed images and iodine material density images. Lower keV simulated monoenergetic images optimize soft tissue tumor to nontumoral attenuation differences and increase contrast to noise ratios to improve lesion detection. Iodine material density images or maps are helpful from a qualitative standpoint for image interpretation because they result in improved detection and characterization of tumors and lymph node involvement, and from a quantitative assessment by enabling interrogation of specific properties of tissues to predict and assess therapeutic response.
Collapse
Affiliation(s)
- Desiree E Morgan
- Department of Radiology University of Alabama at Birmingham, 619 19th Street South, JTN 456, Birmingham, AL 35249-6830, USA.
| |
Collapse
|
38
|
Parakh A, Macri F, Sahani D. Dual-Energy Computed Tomography: Dose Reduction, Series Reduction, and Contrast Load Reduction in Dual-Energy Computed Tomography. Radiol Clin North Am 2018; 56:601-624. [PMID: 29936950 DOI: 10.1016/j.rcl.2018.03.002] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Abstract
Evolution in computed tomography technology and image reconstruction have significantly changed practice. Dual energy computed tomography is being increasingly adopted owing to benefits of material separation, quantification, and improved contrast-to-noise ratio. The radiation dose can match that from single energy computed tomography. Spectral information derived from a polychromatic x-ray beam at different energies yields in image reconstructions that reduce the number of phases in a multiphasic examination and decrease the absolute amount of contrast media. This increased analytical and image processing capability provides new avenues for addressing radiation dose and iodine exposure concerns.
Collapse
Affiliation(s)
- Anushri Parakh
- Department of Radiology, Abdominal Imaging Division, Massachusetts General Hospital, White 270, 55 Fruit Street, Boston, MA 02114, USA
| | - Francesco Macri
- Department of Radiology, Abdominal Imaging Division, Massachusetts General Hospital, White 270, 55 Fruit Street, Boston, MA 02114, USA; Department of Radiology, University Hospital of Nimes, Place di Pr Debre, Nimes 30029, France
| | - Dushyant Sahani
- Department of Radiology, Abdominal Imaging Division, Massachusetts General Hospital, White 270, 55 Fruit Street, Boston, MA 02114, USA.
| |
Collapse
|
39
|
Vernuccio F, Meyer M, Mileto A, Marin D. Use of Dual-Energy Computed Tomography for Evaluation of Genitourinary Diseases. Urol Clin North Am 2018; 45:297-310. [PMID: 30031456 DOI: 10.1016/j.ucl.2018.03.012] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Since its clinical inception a decade ago, dual-energy computed tomography has expanded the array of computed tomography imaging tools available to the practicing abdominal radiologist. Of note, diagnostic solutions for imaging-based evaluation of genitourinary diseases, foremost kidney calculi and renal tumors characterization, represent the apogee applications of dual-energy computed tomography in abdominal imaging. This article reviews clinical applications of dual-energy computed tomography for the assessment of genitourinary diseases.
Collapse
Affiliation(s)
- Federica Vernuccio
- Department of Radiology, Duke University Medical Center, Box 3808 Erwin Road, Durham, NC 27710, USA; Section of Radiology -Di.Bi.Med., University Hospital "Paolo Giaccone", University of Palermo, Via del Vespro 129, 90127, Palermo, Italy
| | - Mathias Meyer
- Department of Radiology, Duke University Medical Center, Box 3808 Erwin Road, Durham, NC 27710, USA
| | - Achille Mileto
- Department of Radiology, University of Washington School of Medicine, Box 357115, 1959 Northeast Pacific Street, Seattle, WA 98195, USA
| | - Daniele Marin
- Department of Radiology, Duke University Medical Center, Box 3808 Erwin Road, Durham, NC 27710, USA.
| |
Collapse
|
40
|
Abdominal Attenuation Values on Virtual and True Unenhanced Images Obtained With Third-Generation Dual-Source Dual-Energy CT. AJR Am J Roentgenol 2018. [DOI: 10.2214/ajr.17.18248] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
41
|
Wortman JR, Uyeda JW, Fulwadhva UP, Sodickson AD. Dual-Energy CT for Abdominal and Pelvic Trauma. Radiographics 2018. [DOI: 10.1148/rg.2018170058] [Citation(s) in RCA: 63] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Affiliation(s)
- Jeremy R. Wortman
- From the Department of Radiology, Division of Emergency Radiology, Brigham and Women’s Hospital, Harvard Medical School, 75 Francis St, Boston, MA 02115
| | - Jennifer W. Uyeda
- From the Department of Radiology, Division of Emergency Radiology, Brigham and Women’s Hospital, Harvard Medical School, 75 Francis St, Boston, MA 02115
| | - Urvi P. Fulwadhva
- From the Department of Radiology, Division of Emergency Radiology, Brigham and Women’s Hospital, Harvard Medical School, 75 Francis St, Boston, MA 02115
| | - Aaron D. Sodickson
- From the Department of Radiology, Division of Emergency Radiology, Brigham and Women’s Hospital, Harvard Medical School, 75 Francis St, Boston, MA 02115
| |
Collapse
|
42
|
Iodine and Fat Quantification for Differentiation of Adrenal Gland Adenomas From Metastases Using Third-Generation Dual-Source Dual-Energy Computed Tomography. Invest Radiol 2018; 53:173-178. [DOI: 10.1097/rli.0000000000000425] [Citation(s) in RCA: 40] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
|
43
|
Toia GV, Kim S, Dighe MK, Mileto A. Dual-Energy Computed Tomography in Body Imaging. Semin Roentgenol 2018; 53:132-146. [PMID: 29861005 DOI: 10.1053/j.ro.2018.02.004] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Affiliation(s)
- Giuseppe V Toia
- Body Imaging Section, Department of Radiology, University of Washington School of Medicine, Seattle, WA 98195
| | - Sooah Kim
- Body Imaging Section, Department of Radiology, University of Washington School of Medicine, Seattle, WA 98195
| | - Manjiri K Dighe
- Body Imaging Section, Department of Radiology, University of Washington School of Medicine, Seattle, WA 98195
| | - Achille Mileto
- Body Imaging Section, Department of Radiology, University of Washington School of Medicine, Seattle, WA 98195.
| |
Collapse
|
44
|
Phantom Validation of Spectral Detector Computed Tomography–Derived Virtual Monoenergetic, Virtual Noncontrast, and Iodine Quantification Images. J Comput Assist Tomogr 2018; 42:959-964. [DOI: 10.1097/rct.0000000000000763] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
45
|
Kalisz K, Halliburton S, Abbara S, Leipsic JA, Albrecht MH, Schoepf UJ, Rajiah P. Update on Cardiovascular Applications of Multienergy CT. Radiographics 2017; 37:1955-1974. [DOI: 10.1148/rg.2017170100] [Citation(s) in RCA: 53] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
46
|
Rassouli N, Etesami M, Dhanantwari A, Rajiah P. Detector-based spectral CT with a novel dual-layer technology: principles and applications. Insights Imaging 2017; 8:589-598. [PMID: 28986761 PMCID: PMC5707218 DOI: 10.1007/s13244-017-0571-4] [Citation(s) in RCA: 159] [Impact Index Per Article: 22.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2017] [Revised: 08/22/2017] [Accepted: 08/24/2017] [Indexed: 01/30/2023] Open
Abstract
Detector-based spectral computed tomography is a novel dual-energy CT technology that employs two layers of detectors to simultaneously collect low- and high-energy data in all patients using standard CT protocols. In addition to the conventional polyenergetic images created for each patient, projection-space decomposition is used to generate spectral basis images (photoelectric and Compton scatter) for creating multiple spectral images, including material decomposition (iodine-only, virtual non-contrast, effective atomic number) and virtual monoenergetic images, on-demand according to clinical need. These images are useful in multiple clinical applications, including- improving vascular contrast, improving lesion conspicuity, decreasing artefacts, material characterisation and reducing radiation dose. In this article, we discuss the principles of this novel technology and also illustrate the common clinical applications. Teaching points • The top and bottom layers of dual-layer CT absorb low- and high-energy photons, respectively. • Multiple spectral images are generated by projection-space decomposition. • Spectral images can be generated in all patients scanned in this scanner.
Collapse
Affiliation(s)
- Negin Rassouli
- Department of Radiology, University Hospitals Cleveland Medical Center, Cleveland, OH, USA
| | - Maryam Etesami
- Department of Radiology, University Hospitals Cleveland Medical Center, Cleveland, OH, USA.,Department of Radiology and Biomedical Imaging, Yale University School of Medicine, New Haven, CT, USA
| | | | - Prabhakar Rajiah
- Department of Radiology, University Hospitals Cleveland Medical Center, Cleveland, OH, USA. .,Cardiothoracic Imaging, Department of Radiology, UT Southwestern Medical Center, 5323 Harry Hines Boulevard, Dallas, TX, 75390, USA.
| |
Collapse
|
47
|
Systematic radiation dose optimization of abdominal dual-energy CT on a second-generation dual-source CT scanner: assessment of the accuracy of iodine uptake measurement and image quality in an in vitro and in vivo investigations. Abdom Radiol (NY) 2017; 42:2562-2570. [PMID: 28470402 DOI: 10.1007/s00261-017-1160-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
PURPOSE To assess the accuracy of iodine quantification in a phantom study at different radiation dose levels with dual-energy dual-source CT and to evaluate image quality and radiation doses in patients undergoing a single-energy and two dual-energy abdominal CT protocols. METHODS In a phantom study, the accuracy of iodine quantification (4.5-23.5 mgI/mL) was evaluated using the manufacturer-recommended and three dose-optimized dual-energy protocols. In a patient study, 75 abdomino-pelvic CT examinations were acquired as follows: 25 CT scans with the manufacturer-recommended dual-energy protocol (protocol A); 25 CT scans with a dose-optimized dual-energy protocol (protocol B); and 25 CT scans with a single-energy CT protocol (protocol C). CTDIvol and objective noise were measured. Five readers scored each scan according to six subjective image quality parameters (noise, contrast, artifacts, visibility of small structures, sharpness, overall diagnostic confidence). RESULTS In the phantom study, differences between the real and measured iodine concentrations ranged from -8.8% to 17.0% for the manufacturer-recommended protocol and from -1.6% to 20.5% for three dose-optimized protocols. In the patient study, the CTDIvol of protocol A, B, and C were 12.5 ± 1.9, 7.5 ± 1.2, and 6.5 ± 1.7 mGycm, respectively (p < 0.001), and the average image noise values were 6.6 ± 1.2, 7.8 ± 1.4, and 9.6 ± 2.2 HU, respectively (p < 0.001). No significant differences in the six subjective image quality parameters were observed between the dose-optimized dual-energy and the single-energy protocol. CONCLUSION A dose reduction of 41% is feasible for the manufacturer-recommended, abdominal dual-energy CT protocol, as it maintained the accuracy of iodine measurements and subjective image quality compared to a single-energy protocol.
Collapse
|
48
|
Marino MA, Silipigni S, Barbaro U, Mazziotti S, Sofia C, Mazzei MA, Ascenti G. Dual Energy CT Scanning in Evaluation of the Urinary Tract. CURRENT RADIOLOGY REPORTS 2017. [DOI: 10.1007/s40134-017-0243-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
49
|
Rizzo S, Radice D, Femia M, De Marco P, Origgi D, Preda L, Barberis M, Vigorito R, Mauri G, Mauro A, Bellomi M. Metastatic and non-metastatic lymph nodes: quantification and different distribution of iodine uptake assessed by dual-energy CT. Eur Radiol 2017; 28:760-769. [PMID: 28835993 DOI: 10.1007/s00330-017-5015-5] [Citation(s) in RCA: 52] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2017] [Revised: 07/27/2017] [Accepted: 08/01/2017] [Indexed: 12/27/2022]
Abstract
OBJECTIVES To evaluate quantification of iodine uptake in metastatic and non-metastatic lymph nodes (LNs) by dual-energy CT (DECT) and to assess if the distribution of iodine within LNs at DECT correlates with the pathological structure. METHODS Ninety LNs from 37 patients (23 with lung and 14 with gynaecological malignancies) were retrospectively selected. Information of LNs sent for statistical analysis included Hounsfield units (HU) at different energy levels; decomposition material densities fat-iodine, iodine-fat, iodine-water, water-iodine. Statistical analysis included evaluation of interobserver variability, material decomposition densities and spatial HU distribution within LNs. RESULTS Interobserver agreement was excellent. There was a significant difference in iodine-fat and iodine-water decompositions comparing metastatic and non-metastatic LNs (p < 0.001); fat-iodine and water-iodine did not show significant differences. HU distribution showed a significant gradient from centre to periphery within non-metastatic LNs that was significant up to 20-30% from the centre, whereas metastatic LNs showed a more homogeneous distribution of HU, with no significant gradient. CONCLUSIONS DECT demonstrated a lower iodine uptake in metastatic compared to non-metastatic LNs. Moreover, the internal iodine distribution showed an evident gradient of iodine distribution from centre to periphery in non-metastatic LNs, and a more homogeneous distribution within metastatic LNs, which corresponded to the pathological structure. KEY POINTS • This study demonstrated a lower iodine uptake in metastatic than non-metastatic LNs. • Internal distribution of HU was different between metastatic and non-metastatic lymph nodes. • The intranodal iodine distribution disclosed a remarkable correlation with the histological LN structure.
Collapse
Affiliation(s)
- Stefania Rizzo
- Department of Radiology, European Institute of Oncology, via Ripamonti 435, 20141, Milan, Italy.
| | - Davide Radice
- Department of Epidemiology and Biostatistics, via Ramusio,1, 20141, Milan, Italy
| | - Marco Femia
- Department of Health Sciences, Università di Milano, via Festa del Perdono 7, 20142, Milan, Italy
| | - Paolo De Marco
- Medical Physics, European Institute of Oncology, via Ripamonti 435, 20141, Milan, Italy
| | - Daniela Origgi
- Medical Physics, European Institute of Oncology, via Ripamonti 435, 20141, Milan, Italy
| | - Lorenzo Preda
- Division of Radiology, National Centre of Oncological Hadrontherapy (CNAO Foundation), Str. Campeggi 53, 27100, Pavia, Italy
- Department of Clinical, Surgical, Diagnostic and Paediatric Sciences, University of Pavia, Pavia, Italy
| | - Massimo Barberis
- Department of Pathology, European Institute of Oncology, via Ripamonti 435, 20141, Milan, Italy
| | - Raffaella Vigorito
- Department of Health Sciences, Università di Milano, via Festa del Perdono 7, 20142, Milan, Italy
| | - Giovanni Mauri
- Division of Interventional Radiology, European Institute of Oncology, via Ripamonti 435, 20141, Milan, Italy
| | - Alberto Mauro
- GE Medical Systems Italia SpA, via Galeno 36, 20126, Milan, Italy
| | - Massimo Bellomi
- Department of Radiology, European Institute of Oncology, via Ripamonti 435, 20141, Milan, Italy
- Department of Oncology, Università di Milano, via Festa del Perdono 7, 20142, Milan, Italy
| |
Collapse
|
50
|
Fulton N, Rajiah P. Abdominal Applications of a Novel Detector-Based Spectral CT. Curr Probl Diagn Radiol 2017; 47:110-118. [PMID: 28673603 DOI: 10.1067/j.cpradiol.2017.05.001] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2017] [Accepted: 05/16/2017] [Indexed: 12/21/2022]
Abstract
Detector-based spectral computed tomography (SDCT) is a recently introduced technology that uses a single x-ray tube and 2 layers of detectors to simultaneously collect low- and high-energy data. In this article, we provide an overview of this novel SDCT technology in abdominal imaging. Several applications of SDCT in abdominal imaging are discussed and illustrated, along with a brief description of current literature on the status of dual-energy computed tomography in these applications. This includes urinary calculus composition, characterization of masses (renal, adrenal, hepatic, and others), tumor perfusion, improving vascular contrast, improving lesion conspicuity, decreasing artifacts, and reducing radiation dose.
Collapse
Affiliation(s)
- Nicholas Fulton
- Department of Radiology, University Hospital Cleveland Medical Center, Cleveland, OH
| | - Prabhakar Rajiah
- Cardiothoracic Imaging, Department of Radiology, UT Southwestern Medical Center, Dallas, TX 75390.
| |
Collapse
|