1
|
Albano D, Pansa S, Messina C, Gitto S, Serpi F, Fusco S, Midiri F, Zagra L, Sconfienza LM. MRI of total hip arthroplasty: technical aspects and imaging findings. Insights Imaging 2024; 15:152. [PMID: 38900339 PMCID: PMC11189891 DOI: 10.1186/s13244-024-01717-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2024] [Accepted: 05/08/2024] [Indexed: 06/21/2024] Open
Abstract
Total hip arthroplasty (THA) is the best surgical approach for treating advanced hip degeneration, providing pain relief, and improved function in most cases. In the past, MR imaging quality has been highly compromised by in-plane distortions, inadequate fat saturation, and other artifacts due to metal components of THA. Technological advancements have made pathologic conditions, which were previously hidden by periprosthetic artifacts, outstanding features due to the optimization of several sequences. To date, several short and long-term complications involving bony and soft-tissue structures may be detected through magnetic resonance imaging (MRI). The use of MRI with adapted sequences and protocols may drastically reduce artifacts thereby providing essential pre-operative elements for planning revision surgery of failed THA. This review has the purpose of conveying new insights to musculoskeletal radiologists about the techniques to suppress metal-related artifacts and the hallmark MRI findings of painful THA. CRITICAL RELEVANCE STATEMENT: Advancements in metal-suppression have given radiologists the opportunity to play an emerging role in THA management. This article provides technical and imaging insights into challenges that can be encountered in cases of THA, which may present complications and characteristic imaging findings. KEY POINTS: Imaging total hip arthroplasty requires adapted MRI protocol and awareness of the common complications. We have reported the available metal-suppression sequences for evaluating total hip arthroplasty. Many structures and conditions should be considered when dealing with painful aseptic or septic arthroplasty.
Collapse
Affiliation(s)
- Domenico Albano
- IRCCS Istituto Ortopedico Galeazzi, Milano, Italy.
- Dipartimento di Scienze Biomediche, Chirurgiche ed Odontoiatriche, Università degli Studi di Milano, Milano, Italy.
| | - Simone Pansa
- Scuola di Specializzazione in Radiodiagnostica, Università degli Studi di Milano, Milano, Italy
| | - Carmelo Messina
- IRCCS Istituto Ortopedico Galeazzi, Milano, Italy
- Dipartimento di Scienze Biomediche per la Salute, Università Degli Studi di Milano, Milano, Italy
| | - Salvatore Gitto
- IRCCS Istituto Ortopedico Galeazzi, Milano, Italy
- Dipartimento di Scienze Biomediche per la Salute, Università Degli Studi di Milano, Milano, Italy
| | - Francesca Serpi
- IRCCS Istituto Ortopedico Galeazzi, Milano, Italy
- Dipartimento di Scienze Biomediche per la Salute, Università Degli Studi di Milano, Milano, Italy
| | - Stefano Fusco
- IRCCS Istituto Ortopedico Galeazzi, Milano, Italy
- Dipartimento di Scienze Biomediche per la Salute, Università Degli Studi di Milano, Milano, Italy
| | | | - Luigi Zagra
- IRCCS Istituto Ortopedico Galeazzi, Milano, Italy
| | - Luca Maria Sconfienza
- IRCCS Istituto Ortopedico Galeazzi, Milano, Italy
- Dipartimento di Scienze Biomediche per la Salute, Università Degli Studi di Milano, Milano, Italy
| |
Collapse
|
2
|
Singh J, Panahifar A, Chernikov R, Dust WN. Pelvic Pseudotumor Associated With a Ceramic Bearing Total Hip. J Am Acad Orthop Surg Glob Res Rev 2024; 8:01979360-202403000-00014. [PMID: 38513193 PMCID: PMC10959560 DOI: 10.5435/jaaosglobal-d-23-00184] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2023] [Revised: 01/19/2024] [Accepted: 02/06/2024] [Indexed: 03/23/2024]
Abstract
Pseudotumors have been well documented to occur most frequently in metal-metal bearing total hip arthroplasties and less frequently in metal-polyethylene bearings. There are few cases in the literature of pseudotumors occurring in ceramic-ceramic articulations. We report a case of a large pelvic pseudotumor in a patient with a ceramic-ceramic bearing articulation in a 67-year-old man. In addition to the usual investigations, we did a detailed wear analysis of the ceramic implants and an examination of the soft tissues for particulate debris. The detailed wear analysis did show evidence of stripe wear; however, the volumetric wear was within the expected range. Synchrotron imaging identified strontium and zirconium debris arising from the ceramic surfaces. Although association does not mean causation, no other cause for the large pseudotumor could be identified and presumably represents an idiosyncratic reaction to ceramic debris.
Collapse
Affiliation(s)
- Jaskaran Singh
- From the Department of Orthopedic Surgery Resident, University of Manitoba, Manitoba, Canada (Dr. Singh); Canadian Light Source, University of Saskatchewan, Saskatoon, Canada (Dr. Panahifar and Dr. Chernikov); Department of Surgery, University of Saskatchewan, Saskatoon, Canada (Dr. Dust)
| | | | | | | |
Collapse
|
3
|
Shufen C, Jinmin L, Xiaohui Z, Bin G. Diagnostic value of magnetic resonance imaging for patients with periprosthetic joint infection: a systematic review. BMC Musculoskelet Disord 2023; 24:801. [PMID: 37814241 PMCID: PMC10561437 DOI: 10.1186/s12891-023-06926-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/13/2022] [Accepted: 09/27/2023] [Indexed: 10/11/2023] Open
Abstract
PURPOSE The purpose of this study was to provide a critical systematic review of the role of magnetic resonance imaging (MRI) as a noninvasive method to assess periprosthetic joint infections (PJIs). METHODS The electronic databases PubMed and EMBASE were searched, since their inception up to March 27, 2022. The included studies evaluated the reproducibility and accuracy of MRI features to diagnose PJIs. The article quality assessment was conducted by the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) and Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2). RESULTS Among 1909 studies identified in the initial search, 8 studies were eligible for final systematic review. The included studies evaluated the reproducibility and accuracy of MRI features to diagnose PJIs. Seven of 8 studies showed good to excellent reliability, but only one article among them in which accuracy was evaluated had a low risk of bias. The intraclass correlation coefficient (ICC) and Cohen coefficient (κ) varied between 0.44 and 1.00. The accuracy varied between 63.9% and 94.4%. Potential MRI features, such as lamellated hyperintense synovitis, edema, fluid collection, or lymphadenopathy, might be valuable for diagnosing PJIs. CONCLUSION The quality of the evidence regarding the role of MRI for PJIs diagnosis was low. There is preliminary evidence that MRI has a noteworthy value of distinguishing suspected periprosthetic joint infection in patients with total knee arthroplasty or total hip arthroplasty, but the definition of specific MRI features related to PJIs diagnosis lacks consensus and standardization. Large-scale studies with robust quality were required to help make better clinical decisions in the future.
Collapse
Affiliation(s)
- Chang Shufen
- Department of Orthopaedics, Lanzhou University Second Hospital, 730000, Lanzhou, Gansu, China
- Gansu Province Clinical Research Center for Orthopaedics, Lanzhou, Gansu, China
| | - Liu Jinmin
- Department of Orthopaedics, Lanzhou University Second Hospital, 730000, Lanzhou, Gansu, China
| | - Zhang Xiaohui
- Department of Orthopaedics, Lanzhou University Second Hospital, 730000, Lanzhou, Gansu, China
- Gansu Province Clinical Research Center for Orthopaedics, Lanzhou, Gansu, China
| | - Geng Bin
- Department of Orthopaedics, Lanzhou University Second Hospital, 730000, Lanzhou, Gansu, China.
- Gansu Province Clinical Research Center for Orthopaedics, Lanzhou, Gansu, China.
| |
Collapse
|
4
|
Hjorth MH, Mechlenburg I, Soballe K, Rømer L, Jakobsen SS, Stilling M. The anatomical location of cystic pseudotumors and muscle atrophy in metal-on-metal resurfacing hip arthroplasty is related to the surgical approach used for implantation. A subgroup analyses of a randomized controlled trial. Arch Orthop Trauma Surg 2023; 143:5967-5976. [PMID: 36802238 DOI: 10.1007/s00402-023-04788-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/09/2022] [Accepted: 01/22/2023] [Indexed: 02/23/2023]
Abstract
BACKGROUND Pseudotumors and muscle atrophy have been associated with metal-on-metal (MoM) resurfacing hip arthroplasty (RHA). We aimed to investigate the influence of the anterolateral (AntLat) and the posterior (Post) surgical approach on the location, grade and prevalence of pseudotumors and muscle atrophy in MoM RHA. PATIENTS AND METHODS Forty-nine patients were randomized to MoM RHA by the AntLat (n = 25) or the Post (n = 24) approach at Aarhus University Hospital. Patients underwent metal artifact reduction sequence (MARS) magnetic resonance imaging (MRI) scans for investigation of location, grade and prevalence of pseudotumors and muscle atrophy. Plain radiographs, metal-ions concentrations and clinical outcome scores were evaluated to compare outcomes of the surgical approaches. RESULTS MRI-detected pseudotumors were seen in 7 of 18 patients (39%) in the AntLat group and in 12 of 22 patients (55%) in the Post group (p = 0.33). Pseudotumors were mainly located anterolaterally to the hip joint in the AntLat group and postero-lateral to the hip joint in the Post group. Higher grades of muscle atrophy of the caudal part of the gluteus medius and minimus (p < 0.004) were seen in the AntLat group, and higher grades of muscle atrophy of the small external rotators were seen in the Post group (p < 0.001). The AntLat group had higher anteversion angles of mean 15.3° (range 6.1-7.5) versus mean 11.5° (range 4.9-22.5) in the Post group (p = 0.02). Metal-ion concentrations and clinical outcome scores were similar between groups (p > 0.08). CONCLUSION Muscle atrophy and pseudotumor location after MoM RHA follow the surgical approach used for implantation. This knowledge may help differentiate between "normal postoperative appearance" and "MoM disease."
Collapse
Affiliation(s)
- Mette Holm Hjorth
- Department of Orthopaedics, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus N, Denmark.
- Department of Clinical Medicine, Aarhus University, Palle Juul-Jensens Boulevard 82, 8200, Aarhus N, Denmark.
| | - Inger Mechlenburg
- Department of Orthopaedics, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus N, Denmark
- Department of Clinical Medicine, Aarhus University, Palle Juul-Jensens Boulevard 82, 8200, Aarhus N, Denmark
| | - Kjeld Soballe
- Department of Orthopaedics, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus N, Denmark
- Department of Clinical Medicine, Aarhus University, Palle Juul-Jensens Boulevard 82, 8200, Aarhus N, Denmark
| | - Lone Rømer
- Department of Radiology, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus N, Denmark
| | - Stig Storgaard Jakobsen
- Department of Orthopaedics, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus N, Denmark
- Department of Clinical Medicine, Aarhus University, Palle Juul-Jensens Boulevard 82, 8200, Aarhus N, Denmark
| | - Maiken Stilling
- Department of Orthopaedics, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus N, Denmark
- Department of Clinical Medicine, Aarhus University, Palle Juul-Jensens Boulevard 82, 8200, Aarhus N, Denmark
| |
Collapse
|
5
|
Gao MA, Tan ET, Neri JP, Li Q, Burge AJ, Potter HG, Koch KM, Koff MF. Diffusion-weighted MRI of total hip arthroplasty for classification of synovial reactions: A pilot study. Magn Reson Imaging 2023; 96:108-115. [PMID: 36496096 PMCID: PMC9929560 DOI: 10.1016/j.mri.2022.12.007] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2022] [Revised: 11/15/2022] [Accepted: 12/04/2022] [Indexed: 12/12/2022]
Abstract
BACKGROUND Conventional quantitative diffusion-weighted imaging (DWI) is sensitive to changes in tissue microstructure, but its application to evaluating patients with orthopaedic hardware has generally been limited due to metallic susceptibility artifacts. The apparent diffusion coefficient (ADC) and T2-values from a multi-spectral imaging (MSI) DWI combined with 2D multi-spectral imaging with a 2D periodically rotated overlapping parallel lines with enhanced reconstruction (2D-MSI PROPELLER DWI) based sequence and a MAVRIC based T2 mapping sequence, respectively, may mitigate the artifact and provide additional quantitative information on synovial reactions in individuals with total hip arthroplasty (THA). The aim of this pilot study is to utilize a 2D-MSI PROPELLER DWI and a MAVRIC-based T2 mapping to evaluate ADC and T2-values of synovial reactions in patients with THA. METHODS Coronal morphologic MRIs from THA patients underwent evaluation of the synovium and were assigned a synovial classification of 'normal', or 'grouped abnormal' (consisting of sub-groups 'infection', 'polymeric', 'metallosis', 'adverse local tissue reaction' [ALTR], or 'non-specific') and type of synovial reaction present (fluid-like, solid-like, or mixed). Regions of interest (ROIs) were placed in synovial reactions for measurement of ADC and T2-values, obtained from the 2D-MSI PROPELLER DWI and T2-MAVRIC sequences, respectively. A one-way analysis of variance (ANOVA) and Kruskal-Wallis rank sum tests were used to compare the differences in ADC and T2-values across the different synovial reaction classifications. A Kruskal-Wallis test was used to compare the ROI areas for the ADC and T2-values. A principal component analysis (PCA) was performed to evaluate the possible effects of ADC values, size of the ADC ROI, T2-values, and size of the T2 ROI with respect to synovial reaction classification. RESULTS Differences of ADC and T2 among the individual synovial reactions were not found. A difference of ADC between 'normal' and 'grouped abnormal' synovial reactions was also not detected even as the ADC area of 'grouped abnormal' synovial reactions were significantly larger (p = 0.02). The 'grouped abnormal' synovial reactions had significantly shorter T2-values than 'normal' synovial reactions (p = 0.02), and that the T2 area of 'grouped abnormal' synovial reactions were significantly larger (p = 0.01). A larger ROI area on the T2-maps was observed in the mixed synovial reaction type as compared to the fluid-like reaction type area (p = 0.01). Heterogeneity was noted in calculated ADC and T2 maps. PCA analysis revealed obvious clustering by the 'normal' and 'grouped abnormal' classifications. CONCLUSIONS 2D-MSI PROPELLER DWI and MAVRIC-T2 generate quantitative images of periprosthetic tissues within clinically feasible scan times. The combination of derived ADC and T2-values with area of synovial reaction may aid in differentiating normal from abnormal synovial reactions between types of synovial reactions in patients with THA.
Collapse
Affiliation(s)
- Madeleine A Gao
- Hospital of Special Surgery, 535 East 70(th) Street, New York, NY 10021, United States of America
| | - Ek T Tan
- Hospital of Special Surgery, 535 East 70(th) Street, New York, NY 10021, United States of America
| | - John P Neri
- Hospital of Special Surgery, 535 East 70(th) Street, New York, NY 10021, United States of America
| | - Qian Li
- Hospital of Special Surgery, 535 East 70(th) Street, New York, NY 10021, United States of America
| | - Alissa J Burge
- Hospital of Special Surgery, 535 East 70(th) Street, New York, NY 10021, United States of America
| | - Hollis G Potter
- Hospital of Special Surgery, 535 East 70(th) Street, New York, NY 10021, United States of America
| | - Kevin M Koch
- Medical College of Wisconsin, 8701 W Watertown Plank Rd, Milwaukee, WI 53226, United States of America
| | - Matthew F Koff
- Hospital of Special Surgery, 535 East 70(th) Street, New York, NY 10021, United States of America.
| |
Collapse
|
6
|
Thejeel B, Endo Y. Imaging of total hip arthroplasty: Part I – Implant design, imaging techniques, and imaging of component wear and fracture. Clin Imaging 2022; 98:74-85. [PMID: 36229386 DOI: 10.1016/j.clinimag.2022.09.008] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2022] [Revised: 09/14/2022] [Accepted: 09/23/2022] [Indexed: 11/17/2022]
Abstract
Despite being one of the most reliable procedures in orthopedic surgery, complications can occur after total hip arthroplasty, and radiology plays an essential role in their evaluation. This article will review the various types of hip arthroplasty and their normal appearances on imaging, followed by mechanisms and imaging appearances of component wear and fracture.
Collapse
Affiliation(s)
- Bashiar Thejeel
- Department of Radiology and Imaging, Hospital for Special Surgery, 535 E. 70th Street, New York, NY 10021, USA
| | - Yoshimi Endo
- Department of Radiology and Imaging, Hospital for Special Surgery, 535 E. 70th Street, New York, NY 10021, USA.
| |
Collapse
|
7
|
Movassaghi K, Patel A, Miller I, Levine BR. An Atypical Adverse Local Tissue Reaction After Ceramic-on-Ceramic Primary Total Hip Arthroplasty. Arthroplast Today 2022; 14:71-75. [PMID: 35252509 PMCID: PMC8889265 DOI: 10.1016/j.artd.2022.01.025] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/23/2021] [Revised: 12/11/2021] [Accepted: 01/15/2022] [Indexed: 11/14/2022] Open
Abstract
Adverse local tissue reaction is an uncommon but frequently described complication after total hip arthroplasty (THA). It is most often associated with metal-on-metal hips and less frequently with metal-on-polyethylene implants as part of a mechanically assisted crevice corrosion process. In this report, we describe a rare case of an atypical adverse local tissue reaction in a patient with a ceramic-on-ceramic THA. Abrasive backside liner wear from a prominent screw head, failure of the liner locking mechanism, and liner fragmentation secondary to component-component impingement created an atypical mass and fluid collection leading to THA failure. This case demonstrates the importance of appropriate cup-liner positioning, thorough workup of pain after THA, and the ability of ceramic debris to cause an associated, atypical adverse local tissue reaction.
Collapse
|
8
|
PIETILÄINEN S, SMEDBERG E, LAAKSONEN I, VENÄLÄINEN MS, LANKINEN P, MÄKELÄ KT. Repeated metal ion measurements and long-term outcome of Durom/MMC total hip arthroplasty. Acta Orthop 2022; 93:241-248. [PMID: 35043969 PMCID: PMC8788692 DOI: 10.2340/17453674.2022.1444] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/21/2021] [Indexed: 01/31/2023] Open
Abstract
Background and purpose - Data regarding long-term behavior of metal ion levels in metal-on-metal total hip arthroplasty (MoM THA) patients is scarce. Therefore, we assessed whether there is any change in whole blood (WB) chromium (Cr), and cobalt (Co) ion measurements in Durom and MMC MoM THA patients over time. The secondary aim was to report the clinical outcomes using these devices in a single district. Patients and methods - Durom and MMC cups were used in 249 MoM THAs from 2005 to 2011 in our district. Median follow-up time was 12 years for Durom THA (interquartile range [IQR] = 3) and 9 years for MMC THA (IQR = 1). A random coefficient model was used to compare individual differences in repeated WB Cr and Co ion measurements. The Kaplan-Meier estimator was used to analyze implant survival with any reason for revision as the endpoint. Results - Geometric means of Cr in Durom THA and MMC THA patients decreased from 2.2 ppb (geometric standard deviation [SD] = 1.9) to 1.5 ppb (geometric SD = 2.5, p< 0.001) and from 1.8 ppb (geometric SD = 1.8) to 1.1 ppb (geometric SD = 2.8, p = 0.01) respectively. The geometric means of Co values remained unchanged. The 10-year survival of Durom THA was 82%, and that of MMC THA 89% for any revision reason as endpoint. Interpretation - WB Cr levels decreased over time, and Co levels remained unchanged at long-term follow-up. Despite this we recommend continuing the follow-up of these devices due to relatively low implant survival.
Collapse
Affiliation(s)
- Sakari PIETILÄINEN
- Department of Orthopaedics and Traumatology, Turku University Hospital,University of Turku
| | | | - Inari LAAKSONEN
- Department of Orthopaedics and Traumatology, Turku University Hospital,University of Turku
| | - Mikko S VENÄLÄINEN
- Turku Bioscience Centre, University of Turku and Åbo Akademi University,Division of Medical Imaging, Department of Medical Physics, Turku University Hospital, Turku
| | - Petteri LANKINEN
- Department of Orthopaedics and Traumatology, Turku University Hospital,University of Turku,Department of Administration, Satakunta Central Hospital, Pori, Finland
| | - Keijo T MÄKELÄ
- Department of Orthopaedics and Traumatology, Turku University Hospital,University of Turku
| |
Collapse
|
9
|
Koff MF, Gao MA, Neri JP, Chiu YF, Lin BQ, Burge AJ, Su E, Padgett DE, Potter HG. Adverse Local Tissue Reactions are Common in Asymptomatic Individuals After Hip Resurfacing Arthroplasty: Interim Report from a Prospective Longitudinal Study. Clin Orthop Relat Res 2021; 479:2633-2650. [PMID: 34232144 PMCID: PMC8726542 DOI: 10.1097/corr.0000000000001882] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/13/2020] [Accepted: 06/08/2021] [Indexed: 01/31/2023]
Abstract
BACKGROUND The evaluation of the natural history prevalence of adverse local tissue reactions (ALTRs) using MRI has focused only on metal-on-metal (MoM) bearing surfaces without comparison to nonMoM bearing surfaces. QUESTIONS/PURPOSES To determine (1) the longitudinal changes and differences in blood metal ion levels in patients with hip resurfacing arthroplasty (HRA), ceramic-on-ceramic (CoC) THA, and metal-on-polyethylene (MoP) THA compared with those undergoing ceramic-on-polyethylene (CoP) THA; (2) how the longitudinal change of synovial reaction classification in patients with HRA, CoC THA, and MoP THA compares with those undergoing CoP THA, and whether there is an association between the presence of an ALTR or metallosis on MRI with corresponding patient-reported outcomes, or the presence of capsular dehiscence; and (3) differences in blood metal ion levels between patients undergoing HRA with an ALTR or metallosis on MRI and those with HRA without these conditions. METHODS Between March 2014 and February 2019, 22,723 patients underwent primary HRA and THA at one center. Patients received an HRA based on their desired athletic level after surgery and the presence of normal acetabular and proximal femoral bone morphology without osteopenia or osteoporosis. Two percent (342 of 22,723) of patients were contacted to participate, and 71% (243 of 342 hips in 206 patients) were enrolled for analysis at baseline. The patients underwent arthroplasty for degenerative joint disease, and 25 patients withdrew over the course of the study. We included patients who were more than 1 year postarthroplasty. All participants had an MRI examination and blood serum ion testing and completed a Hip Disability and Osteoarthritis Outcome Score survey annually for four years (baseline, year 1, year 2, year 3). Morphologic and susceptibility-reduced MR images were evaluated by a single radiologist not involved in the care of patients for the presence and classification of synovitis (Gwet AC1: 0.65 to 0.97), synovial thickness, and volume (coefficient of repeatability: 1.8 cm3). Linear mixed-effects models were used to compare the mean synovial thickness, synovial volume, and Hip Disability and Osteoarthritis Outcome Score subscales between bearing surfaces at each timepoint and within each bearing surface over time. Marginal Cox proportional hazards models were used to compare the time to and the risk of developing ALTR only, metallosis only, and ALTR or metallosis between bearing surfaces. All models were adjusted for age, sex, BMI, and length of implantation based on known confounders for hip arthroplasty. Adjustment for multiple comparisons was performed using the Dunnett-Hsu method. RESULTS Patients with unilateral HRA had higher cobalt and chromium serum ion levels (baseline: 1.8 ± 0.8 ppb, year 1: 2.0 ± 1.5 ppb, year 2: 2.1 ± 1.2 ppb, year 3: 1.6 ± 0.7 ppb) than those with unilateral CoP bearings (baseline: 0.0 ± 0.1 ppb, year 1: 0.1 ± 0.3 ppb, year 2: 0.0 ± 0.2 ppb, year 3: 0.0 ± 0.0 ppb) at all timepoints (p < 0.001 for each time point). More patients who received an HRA developed ALTR or metallosis on MRI than did patients with CoP bearings (hazard ratio 4.8 [95% confidence interval 1.2 to 18.4]; p = 0.02). There was no association between the longitudinal change of synovial reaction to ALTR or metallosis on MRI with patient-reported outcomes. In addition, there was no association between the presence of dehiscence at baseline and the subsequent development of ALTR or metallosis, as seen on MRI. There were elevated cobalt (4.7 ± 3.5 ppb) and chromium (4.7 ± 2.6 ppb) serum levels in patients with unilateral HRA who had an ALTR or metallosis present on MRI at year 1 compared with patients without an ALTR or metallosis on MRI (cobalt: 1.8 ± 1.0 ppb, mean difference 4.7 ppb [95% CI 3.3 to 6.0]; p < 0.001; chromium: 2.3 ± 0.5 ppb, mean difference 3.6 ppb [95% CI 2.2 to 5.0]; p < 0.001) as well as for chromium at year 3 (3.9 ± 2.4 ppb versus 2.2 ± 1.1 ppb, mean difference 1.3 ppb [95% CI 0.3 to 2.4]; p = 0.01). CONCLUSION We found a higher proportion of ALTR or metallosis on MRI in patients with HRA compared with patients with CoP, even when patient self-assessed symptomatology of those with an ALTR or metallosis on MRI was not different than the absence of these features. MRI detected ALTRs in high-function patients, emphasizing that an annual clinical assessment dependent on survey or blood ion testing alone may not detect soft tissue complications. The results of this study are in line with prior consensus recommendations of using MRI as part of a routine follow-up protocol for this patient population. LEVEL OF EVIDENCE Level III, therapeutic study.
Collapse
Affiliation(s)
- Matthew F. Koff
- MRI Research Laboratory, Hospital for Special Surgery, New York, NY, USA
| | - Madeleine A. Gao
- MRI Research Laboratory, Hospital for Special Surgery, New York, NY, USA
| | - John P. Neri
- MRI Research Laboratory, Hospital for Special Surgery, New York, NY, USA
| | - Yu-fen Chiu
- Biostatistics Core, Hospital for Special Surgery, New York, NY, USA
| | - Bin Q. Lin
- Biostatistics Core, Hospital for Special Surgery, New York, NY, USA
| | - Alissa J. Burge
- MRI Research Laboratory, Hospital for Special Surgery, New York, NY, USA
| | - Edwin Su
- Adult Reconstruction and Joint Replacement Division, Hospital for Special Surgery, New York, NY, USA
| | - Douglas E. Padgett
- Adult Reconstruction and Joint Replacement Division, Hospital for Special Surgery, New York, NY, USA
| | - Hollis G. Potter
- MRI Research Laboratory, Hospital for Special Surgery, New York, NY, USA
| |
Collapse
|
10
|
MRI Characteristics of Adverse Local Tissue Reactions Associated With Intraoperative Tissue Damage and Poor Revision Surgery Outcomes: A Systematic Review. J Am Acad Orthop Surg 2021; 29:e1025-e1033. [PMID: 33201043 DOI: 10.5435/jaaos-d-20-00793] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/01/2020] [Accepted: 08/29/2020] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Metal artifact reductions sequence (MARS) MRI has been established as a cross-sectional imaging modality for diagnosis of adverse local tissue reaction (ALTR). This study aims to evaluate the current literature regarding the characteristics of MARS MRI associated with intraoperative tissue necrosis and postoperative complications in patients undergoing revision THA because of ALTR. METHODS We systematically searched the literature that included reporting MRI characteristics of ALTR in failed THA and their correlation with intraoperative findings and postoperative outcomes. RESULTS A total of 617 studies were assessed, and 15 studies met the inclusion criteria. Synovial wall thickness correlated with increasing ALVAL grade, however, weakly with tissue necrosis. Synovial composition of mixed or solid features and the presence of abductor disruption correlated with complications and tissue necrosis. Tissue edema was a poor predictor of aseptic lymphocyte-dominant vasculitis-associated lesion (ALVAL) grade or tissue necrosis. DISCUSSION MARS MRI synovial composition including mixed and solid features and the presence of abductor disruption provide the best prognostic characteristics associated with intraoperative soft-tissue necrosis and revision surgery outcome. These prognostic characteristics on MRI may assist surgeons with improved criteria for intervention and preoperative patient counseling.
Collapse
|
11
|
Cheung J, Neri JP, Gao MA, Lin B, Burge AJ, Potter HG, Koch KM, Koff MF. Clinical Feasibility of Multi-Acquisition Variable-Resonance Image Combination-Based T2 Mapping near Hip Arthroplasty. HSS J 2021; 17:165-173. [PMID: 34421426 PMCID: PMC8361595 DOI: 10.1177/1556331621994801] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/18/2020] [Accepted: 10/21/2020] [Indexed: 11/16/2022]
Abstract
Background: Hip arthroplasty is increasingly prevalent, and early detection of complications can improve outcomes. Quantitative magnetic resonance imaging (qMRI) methods using multi-acquisition variable-resonance image combination (MAVRIC) may allow for the assessment of soft tissues in close proximity to hip arthroplasty devices. Question/Purposes: We sought to determine the clinical feasibility of MAVRIC-based T2 mapping as a qMRI approach for assessing synovial reactions in patients with a hip arthroplasty device. We hypothesized that there would be differences in T2 metrics by synovial type, clinical impression, and clinical findings related to synovitis. Methods: We conducted a cross-sectional study of 141 subjects with 171 hip arthroplasties with greater than 1 year post-implantation. We enrolled subjects who had had a primary total hip arthroplasty or hip resurfacing arthroplasty between May 2019 and March 2020, excluding those with a revision hip arthroplasty and those with standard safety contraindications for receiving an MRI. Institutional standard 2D fast spin echo (FSE), short-tau inversion recovery (STIR), and susceptibility-reduced MAVRIC morphological MR images were acquired for each hip and followed by a dual-echo acquisition MAVRIC T2 mapping sequence. Results: While 131 subjects (81%) were classified as having a "normal" synovial reaction, significantly longer T2 values were found for fluid synovial reactions compared with mixed reactions. In addition, subjects with synovial dehiscence and decompression present had T2 prolongation. Larger synovial volumes were found in subjects with low-signal intensity deposits. Conclusions: MAVRIC-based T2 mapping is clinically feasible and there are significant quantitative differences based on type of synovial reaction. Patients undergoing hip arthroscopy revision surgery will warrant comparison of T2 values with direct histologic assessment of a tissue sample obtained intraoperatively. The approach used in this study may be used for a quantitative evaluation and monitoring of soft tissues around metal implants.
Collapse
Affiliation(s)
- Jacky Cheung
- MRI Laboratory, Department of Radiology and Imaging, Hospital for Special Surgery, New York, NY, USA
| | - John P. Neri
- MRI Laboratory, Department of Radiology and Imaging, Hospital for Special Surgery, New York, NY, USA
| | - Madeleine A. Gao
- MRI Laboratory, Department of Radiology and Imaging, Hospital for Special Surgery, New York, NY, USA
| | - Bin Lin
- MRI Laboratory, Department of Radiology and Imaging, Hospital for Special Surgery, New York, NY, USA
| | - Alissa J. Burge
- MRI Laboratory, Department of Radiology and Imaging, Hospital for Special Surgery, New York, NY, USA
| | - Hollis G. Potter
- MRI Laboratory, Department of Radiology and Imaging, Hospital for Special Surgery, New York, NY, USA
| | - Kevin M. Koch
- Department of Radiology, Medical College of Wisconsin, Milwaukee, WI, USA
| | - Matthew F. Koff
- MRI Laboratory, Department of Radiology and Imaging, Hospital for Special Surgery, New York, NY, USA,Matthew F. Koff, PhD, Department of Radiology and Imaging, Hospital for Special Surgery, New York, NY 10021, USA.
| |
Collapse
|
12
|
Laaksonen I, Galea VP, Connelly JW, Matuszak SJ, Marega L, Madanat R, Muratoglu O, Malchau H. Progression of adverse local tissue reaction in ASR metal-on-metal hip arthroplasty: a longitudinal MARS-MRI study at mid- to long-term. Hip Int 2021; 31:369-377. [PMID: 31868016 DOI: 10.1177/1120700019894668] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND Despite the large number of studies assessing adverse local tissue reaction (ALTR) in metal-on-metal (MoM) hip implants, there is still a lack of knowledge about the natural progression of ALTR. The aims of this study were to describe the natural course of changes in ALTR at mid- to long-term follow-up for patients treated with metal-on-metal hip arthroplasty and to determine possible risk factors associated with change in ALTR. METHODS A total of 158 patients (158 hips), 109 MoM hip resurfacing arthroplasties (HRAs) and 49 MoM total hip arthroplasties (THAs), with 2 clinical follow-ups including MARS-MRIs were included. The mean time from index operation to the first visit was 7.6 years (range 3.4-11.4 years), and the mean time between the 2 visits was 1.0 year (range 0.7-1.6 years). RESULTS The proportion of patients with moderate or severe ALTR did not increase significantly between the first and second visit for the MoM HRA group (14.7-15.6%; p = 0.850) or the MoM THA group (32.7-36.7%; p = 0.671). 8 (7.3%) HRA patients and 9 (18.4%) THA patients progressed in ALTR grade. None of the collected clinical variables was sensitive or specific in identifying patients with ALTR progression. CONCLUSIONS Although ALTR prevalence was high in our cohort, clinically significant ALTR progression was rare. We were unable to find any predictors associated with ALTR change. This indicates that MARS-MRI remains a valuable tool in the follow-up of patients treated with MoM hip devices in identifying patients who may need revision surgery.
Collapse
Affiliation(s)
- Inari Laaksonen
- The Harris Orthopedic Laboratory, Massachusetts General Hospital, Department of Orthopaedic Surgery, Boston, MA, USA
| | - Vincent P Galea
- The Harris Orthopedic Laboratory, Massachusetts General Hospital, Department of Orthopaedic Surgery, Boston, MA, USA
| | - James W Connelly
- The Harris Orthopedic Laboratory, Massachusetts General Hospital, Department of Orthopaedic Surgery, Boston, MA, USA
| | - Sean J Matuszak
- The Harris Orthopedic Laboratory, Massachusetts General Hospital, Department of Orthopaedic Surgery, Boston, MA, USA
| | - Luca Marega
- Casa di Cura S. Anna, Via del Franzone, Brescia, Italy
| | - Rami Madanat
- Department of Orthopaedics and Traumatology, Helsinki University Hospital, Sairaalakatu, Vantaa, Finland
| | - Orhun Muratoglu
- The Harris Orthopedic Laboratory, Massachusetts General Hospital, Department of Orthopaedic Surgery, Boston, MA, USA
| | - Henrik Malchau
- The Harris Orthopedic Laboratory, Massachusetts General Hospital, Department of Orthopaedic Surgery, Boston, MA, USA
| |
Collapse
|
13
|
Jennings JM, Czuczman GJ, Johnson RM, Dennis DA. Metal Artifact Reduction Sequence Magnetic Resonance Imaging Abnormalities in Asymptomatic Patients With a Ceramic-on-Ceramic Total Hip Replacement. J Arthroplasty 2021; 36:612-615. [PMID: 32950341 DOI: 10.1016/j.arth.2020.07.082] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/24/2020] [Revised: 07/24/2020] [Accepted: 07/31/2020] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Metal artifact reduction sequence (MARS) magnetic resonance imaging (MRI) has recently gained increased utilization as a screening modality in patients with a total hip arthroplasty (THA). Fluid collections have been documented in asymptomatic patients with various bearing surfaces. The purpose of this study is to determine the frequency and types of MARS MRI-documented abnormalities in asymptomatic patients with a ceramic-on-ceramic (CoC) THA. METHODS Thirty-seven patients (42 hips) with a minimum 2-year follow-up after THA with CoC THA implants were enrolled in this study. The inclusion criteria were the absence of hip pain and the availability of appropriate follow-up radiographs. All patients underwent a MARS MRI. Abnormalities were documented using a previously described method. RESULTS Fluid collections were observed in 8 (19%) asymptomatic hips in this cohort. Four of the 8 hips demonstrated intracapsular synovitis, and 3 of these hips had a thickened synovium. Extra-articular fluid collections with direct intra-articular communication were identified in 4 hips, with 2 of these hips demonstrating synovial thickening. No signs of osteolysis were noted on radiographs or the MARS MRI scans. CONCLUSION Asymptomatic fluid collections occur in patients after CoC THA similar to other bearing surfaces. We continue to follow these patients in an effort to determine the clinical significance and natural history of these findings. LEVEL OF EVIDENCE Diagnostic Level IV.
Collapse
Affiliation(s)
- Jason M Jennings
- Colorado Joint Replacement, Porter Adventist Hospital, Denver, CO; Department of Biomedical Engineering, University of Denver, Denver, CO
| | | | | | - Douglas A Dennis
- Colorado Joint Replacement, Porter Adventist Hospital, Denver, CO; Department of Biomedical Engineering, University of Denver, Denver, CO; Department of Biomedical Engineering, University of Tennessee, Knoxville, TN; Department of Orthopaedics, University of Colorado Health School of Medicine, Aurora, CO
| |
Collapse
|
14
|
Identifying Musculoskeletal Pain Generators Using Molecular Imaging. Mol Imaging 2021. [DOI: 10.1016/b978-0-12-816386-3.00076-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
|
15
|
Attard V, Li CY, Self A, Mann DA, Borthwick LA, O’Connor P, Deehan DJ, Kalson NS. Quantification of intra-articular fibrosis in patients with stiff knee arthroplasties using metal-reduction MRI. Bone Joint J 2020; 102-B:1331-1340. [PMID: 32993344 PMCID: PMC7517723 DOI: 10.1302/0301-620x.102b10.bjj-2020-0841.r1] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
AIMS Stiffness is a common complication after total knee arthroplasty (TKA). Pathogenesis is not understood, treatment options are limited, and diagnosis is challenging. The aim of this study was to investigate if MRI can be used to visualize intra-articular scarring in patients with stiff, painful knee arthroplasties. METHODS Well-functioning primary TKAs (n = 11), failed non-fibrotic TKAs (n = 5), and patients with a clinical diagnosis of fibrosis1 (n = 8) underwent an MRI scan with advanced metal suppression (Slice Encoding for Metal Artefact Correction, SEMAC) with gadolinium contrast. Fibrotic tissue (low intensity on T1 and T2, low-moderate post-contrast enhancement) was quantified (presence and tissue thickness) in six compartments: supra/infrapatella, medial/lateral gutters, and posterior medial/lateral. RESULTS Fibrotic tissue was identified in all patients studied. However, tissue was significantly thicker in fibrotic patients (4.4 mm ± 0.2 mm) versus non-fibrotic (2.5 mm ± 0.4 mm) and normal TKAs (1.9 mm ± 0.2 mm, p = < 0.05). Significant (> 4 mm thick) tissue was seen in 26/48 (54%) of compartments examined in the fibrotic group, compared with 17/30 (57%) non-fibrotic, and 10/66 (15%) normal TKAs. Although revision surgery did improve range of movement (ROM) in all fibrotic patients, clinically significant restriction remained post-surgery. CONCLUSION Stiff TKAs contain intra-articular fibrotic tissue that is identifiable by MRI. Studies should evaluate whether MRI is useful for surgical planning of debridement, and as a non-invasive measurement tool following interventions for stiffness caused by fibrosis. Revision for stiffness can improve ROM, but outcomes are sub-optimal and new treatments are required. Cite this article: Bone Joint J 2020;102-B(10):1331-1340.
Collapse
Affiliation(s)
- Veronica Attard
- Leeds NIHR Biomedical Research Centre, Leeds Institute of Rheumatic and Musculoskeletal Medicine, Chapel Allerton Hospital, Leeds, UK
| | - Cheuk Yin Li
- Department of Orthopaedics, Freeman Hospital, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle upon Tyne, UK
| | - Alexander Self
- Department of Radiology, Royal Victoria Infirmary, Newcastle University Hospitals NHS Foundation Trust, Newcastle upon Tyne, UK
| | - Derek A. Mann
- Fibrosis Research Group, Institute of Cellular Medicine, Newcastle University, Newcastle upon Tyne, UK
| | - Lee A. Borthwick
- Fibrosis Research Group, Institute of Cellular Medicine, Newcastle University, Newcastle upon Tyne, UK
| | - Phil O’Connor
- Leeds NIHR Biomedical Research Centre, Leeds Institute of Rheumatic and Musculoskeletal Medicine, Chapel Allerton Hospital, Leeds, UK
| | - David J. Deehan
- Department of Orthopaedics, Freeman Hospital, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle upon Tyne, UK
- Fibrosis Research Group, Institute of Cellular Medicine, Newcastle University, Newcastle upon Tyne, UK
| | - Nicholas S. Kalson
- Department of Orthopaedics, Freeman Hospital, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle upon Tyne, UK
- Fibrosis Research Group, Institute of Cellular Medicine, Newcastle University, Newcastle upon Tyne, UK
| |
Collapse
|
16
|
Yoon D, Kogan F, Gold GE, Biswal S. Identifying Musculoskeletal Pain Generators Using Clinical PET. Semin Musculoskelet Radiol 2020; 24:441-450. [DOI: 10.1055/s-0040-1713607] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
AbstractIdentifying the source of a person's pain is a significant clinical challenge because the physical sensation of pain is believed to be subjective and difficult to quantify. The experience of pain is not only modulated by the individual's threshold to painful stimuli but also a product of the person's affective contributions, such as fear, anxiety, and previous experiences. Perhaps then to quantify pain is to examine the degree of nociception and pro-nociceptive inflammation, that is, the extent of cellular, chemical, and molecular changes that occur in pain-generating processes. Measuring changes in the local density of receptors, ion channels, mediators, and inflammatory/immune cells that are involved in the painful phenotype using targeted, highly sensitive, and specific positron emission tomography (PET) radiotracers is therefore a promising approach toward objectively identifying peripheral pain generators. Although several preclinical radiotracer candidates are being developed, a growing number of ongoing clinical PET imaging approaches can measure the degree of target concentration and thus serve as a readout for sites of pain generation. Further, when PET is combined with the spatial and contrast resolution afforded by magnetic resonance imaging, nuclear medicine physicians and radiologists can potentially identify pain drivers with greater accuracy and confidence. Clinical PET imaging approaches with fluorine-18 fluorodeoxyglucose, fluorine-18 sodium fluoride, and sigma-1 receptor PET radioligand and translocator protein radioligands to isolate the source of pain are described here.
Collapse
Affiliation(s)
- Daehyun Yoon
- Division of Musculoskeletal Radiology, Department of Radiology, Stanford University School of Medicine, Stanford, California
| | - Feliks Kogan
- Division of Musculoskeletal Radiology, Department of Radiology, Stanford University School of Medicine, Stanford, California
| | - Garry E. Gold
- Division of Musculoskeletal Radiology, Department of Radiology, Stanford University School of Medicine, Stanford, California
| | - Sandip Biswal
- Division of Musculoskeletal Radiology, Department of Radiology, Stanford University School of Medicine, Stanford, California
| |
Collapse
|
17
|
Galley J, Sutter R, Stern C, Filli L, Rahm S, Pfirrmann CWA. Diagnosis of Periprosthetic Hip Joint Infection Using MRI with Metal Artifact Reduction at 1.5 T. Radiology 2020; 296:98-108. [PMID: 32396046 DOI: 10.1148/radiol.2020191901] [Citation(s) in RCA: 39] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Background MRI with metal artifact reduction has gained importance in assessment of pain with total hip arthroplasty (THA). However, its role in diagnosis of periprosthetic joint infection (PJI) has not been well defined. Purpose To evaluate findings of PJI after THA and to determine the diagnostic performance of 1.5-T MRI with metal artifact reduction. Materials and Methods Dedicated compressed sensing-based slice encoding for metal artifact correction 1.5-T MRI examinations (from January 2015 to April 2018) in patients with THA PJI (infection group) and noninfected THA (control group) were retrospectively evaluated by two musculoskeletal radiologists. Fisher exact test was used to compare the groups. Sensitivity, specificity, and accuracy were evaluated for each finding. Interobserver reliability was assessed with κ statistics. Results Forty patients (mean age, 69 years ± 11 [standard deviation]; 26 men) in the infection group and 100 patients (mean age, 67 years ± 11; 42 men) in the control group were evaluated. Periosteal reaction, capsule edema, and intramuscular edema differed between the two groups (P < .001 for each finding). Periosteal reaction was found in 31 of 40 patients with infection and 10 of 100 participants in the control group (sensitivity, 78%; specificity, 90%; accuracy, 86%); capsule edema was found in 33 of 40 (infection group) and five of 100 (control group) (sensitivity, 83%; specificity, 95%; accuracy, 91%); and intramuscular edema was found in 38 of 40 (infection group) and 14 of 100 (control group) (sensitivity, 95%; specificity, 86%; accuracy, 89%). Interobserver agreement was almost perfect, with κ values between 0.88 and 0.92. No difference between the two groups was found regarding the presence of osteolysis (infection group, 23 of 40; control group, 60 of 100), bone marrow edema (39 of 40 vs 87 of 100), effusion (20 of 40 vs 26 of 100), abductor tendon lesion (22 of 40 vs 62 of 100), or bursitis (14 of 40 vs 34 of 100) (P > .05 for each finding). Conclusion The presence of periosteal reaction, capsule edema, and intramuscular edema after total hip arthroplasty at 1.5-T MRI with metal artifact reduction had a high accuracy in evaluation of periprosthetic joint infection. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Zanetti in this issue.
Collapse
Affiliation(s)
- Julien Galley
- From the Departments of Radiology (J.G., R.S., C.S., L.F., C.W.A.P.) and Orthopedic Surgery (S.R.), Balgrist University Hospital, University of Zurich, Forchstrasse 340, 8008 Zürich, Switzerland; and Department of Radiology, HFR, University of Fribourg, Fribourg, Switzerland (J.G.)
| | - Reto Sutter
- From the Departments of Radiology (J.G., R.S., C.S., L.F., C.W.A.P.) and Orthopedic Surgery (S.R.), Balgrist University Hospital, University of Zurich, Forchstrasse 340, 8008 Zürich, Switzerland; and Department of Radiology, HFR, University of Fribourg, Fribourg, Switzerland (J.G.)
| | - Christoph Stern
- From the Departments of Radiology (J.G., R.S., C.S., L.F., C.W.A.P.) and Orthopedic Surgery (S.R.), Balgrist University Hospital, University of Zurich, Forchstrasse 340, 8008 Zürich, Switzerland; and Department of Radiology, HFR, University of Fribourg, Fribourg, Switzerland (J.G.)
| | - Lukas Filli
- From the Departments of Radiology (J.G., R.S., C.S., L.F., C.W.A.P.) and Orthopedic Surgery (S.R.), Balgrist University Hospital, University of Zurich, Forchstrasse 340, 8008 Zürich, Switzerland; and Department of Radiology, HFR, University of Fribourg, Fribourg, Switzerland (J.G.)
| | - Stefan Rahm
- From the Departments of Radiology (J.G., R.S., C.S., L.F., C.W.A.P.) and Orthopedic Surgery (S.R.), Balgrist University Hospital, University of Zurich, Forchstrasse 340, 8008 Zürich, Switzerland; and Department of Radiology, HFR, University of Fribourg, Fribourg, Switzerland (J.G.)
| | - Christian W A Pfirrmann
- From the Departments of Radiology (J.G., R.S., C.S., L.F., C.W.A.P.) and Orthopedic Surgery (S.R.), Balgrist University Hospital, University of Zurich, Forchstrasse 340, 8008 Zürich, Switzerland; and Department of Radiology, HFR, University of Fribourg, Fribourg, Switzerland (J.G.)
| |
Collapse
|
18
|
Dyke JP, Garfinkel JH, Volpert L, Sanders A, Newcomer M, Dutruel SP, Sofka CM, Ellis SJ, Demetracopoulos CA. Imaging of Bone Perfusion and Metabolism in Subjects Undergoing Total Ankle Arthroplasty Using 18F-Fluoride Positron Emission Tomography. Foot Ankle Int 2019; 40:1351-1357. [PMID: 31597454 DOI: 10.1177/1071100719882717] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Total ankle arthroplasty (TAA) continues to exhibit a relatively high incidence of complications and need for revision surgery compared to knee and hip arthroplasty. One common mode of failure in TAA is talar component subsidence. This may be caused by disruption in the talar blood supply related to the operative technique. The purpose of this study was to quantify changes in talar bone perfusion and turnover before and after TAA with the INBONE II system using 18F-fluoride positron emission tomography / computed tomography (PET/CT). METHODS Nine subjects (5 M/4 F) aged 68.9 ± 8.2 years were enrolled for 18F-fluoride PET/CT imaging before and 3 months after TAA. Regions of interest (ROI) were placed on the postoperative CT images in the body of the talus beneath the talar component and overlaid on the fused static PET images. Standard uptake values (SUVs) along with dynamic K1 (bone blood flow) and ki (bone metabolism or osteoblastic turnover) were calculated. RESULTS The SUV underneath the talar component compared to that measured at baseline before surgery was 1.93 ± 0.29 preoperatively vs 2.47 ± 0.37 postoperatively (P > .05). K1 was 0.84 ± 0.16 mL/min/mL preoperatively vs 1.51 ± 0.23 mL/min/mL postoperatively (P = .026). ki was constant at 0.09 ± 0.03 mL/min/mL preoperatively vs 0.12 ± 0.03 mL/min/mL postoperatively (P > .05). CONCLUSION Our study was the first to link 18F-fluoride PET/CT with pre-post evaluation of total ankle replacements. The study quantified perfusion within the talus beneath the TAA implant supporting the hypothesis that perfusion of the talus remained intact after surgery. LEVEL OF EVIDENCE Level II, prospective cohort study with development of diagnostic criteria.
Collapse
Affiliation(s)
- Jonathan P Dyke
- Citigroup Biomedical Imaging Center, Weill Cornell Medicine, New York, NY, USA
| | | | - Lauren Volpert
- Foot and Ankle Service, Hospital for Special Surgery, New York, NY, USA
| | - Austin Sanders
- Foot and Ankle Service, Hospital for Special Surgery, New York, NY, USA
| | - Meghan Newcomer
- Foot and Ankle Service, Hospital for Special Surgery, New York, NY, USA
| | | | - Carolyn M Sofka
- Department of Radiology, Hospital for Special Surgery, New York, NY, USA
| | - Scott J Ellis
- Foot and Ankle Service, Hospital for Special Surgery, New York, NY, USA
| | | |
Collapse
|
19
|
MRI Findings at the Bone-Component Interface in Symptomatic Unicompartmental Knee Arthroplasty and the Relationship to Radiographic Findings. HSS J 2018; 14:286-293. [PMID: 30258334 PMCID: PMC6148582 DOI: 10.1007/s11420-018-9629-1] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/09/2018] [Accepted: 07/26/2018] [Indexed: 02/07/2023]
Abstract
BACKGROUND The most common modes of failure of cemented unicompartmental knee arthroplasty (UKA) designs are aseptic loosening and unexplained pain at short- to mid-term follow-up, which is likely linked to early fixation failure. Determining these modes of failure remains challenging; conventional radiographs are limited for use in assessing radiolucent lines, with only fair sensitivity and specificity for aseptic loosening. QUESTIONS/PURPOSES We sought to characterize the bone-component interface of patients with symptomatic cemented medial unicompartmental knee arthroplasty (UKA) using magnetic resonance imaging (MRI) and to determine the relationship between MRI and conventional radiographic findings. METHODS This retrospective observational study included 55 consecutive patients with symptomatic cemented UKA. All underwent MRI with addition of multiacquisition variable-resonance image combination (MAVRIC) at an average of 17.8 ± 13.9 months after surgery. MRI studies were reviewed by two independent musculoskeletal radiologists. MRI findings at the bone-cement interface were quantified, including bone marrow edema, fibrous membrane, osteolysis, and loosening. Radiographs were reviewed for existence of radiolucent lines. Inter-rater agreement was determined using Cohen's κ statistic. RESULTS The vast majority of symptomatic UKA patients demonstrated bone marrow edema pattern (71% and 75%, respectively) and fibrous membrane (69% and 89%, respectively) at the femoral and tibial interface. Excellent and substantial inter-rater agreement was found for the femoral and tibial interface, respectively. Furthermore, MRI findings and radiolucent lines observed on conventional radiographs were poorly correlated. CONCLUSION MRI with the addition of MAVRIC sequences could be a complementary tool for assessing symptomatic UKA and for quantifying appearances at the bone-component interface. This technique showed good reproducibility of analysis of the bone-component interface after cemented UKA. Future studies are necessary to define the bone-component interface of symptomatic and asymptomatic UKA patients.
Collapse
|
20
|
Frondlike Synovitis on MRI and Correlation With Polyethylene Surface Damage of Total Knee Arthroplasty. AJR Am J Roentgenol 2017; 209:W231-W237. [DOI: 10.2214/ajr.16.17443] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
21
|
Comparison of Pre-Revision Magnetic Resonance Imaging and Operative Findings in Mechanically Assisted Crevice Corrosion in Symptomatic Metal-on-Polyethylene Total Hip Arthroplasties. J Arthroplasty 2017; 32:2535-2545. [PMID: 28479059 DOI: 10.1016/j.arth.2017.03.021] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/18/2016] [Revised: 02/18/2017] [Accepted: 03/09/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Failed total hip arthroplasty (THA) caused by mechanically assisted crevice corrosion (MACC) has serious consequences-notably, adverse local tissue reactions. Metal artifact reduction sequence (MARS) magnetic resonance imaging (MRI) has been used to evaluate failed THA for other reasons but has not been assessed for the analysis of cases of MACC in the setting of metal-on-polyethylene arthroplasties. METHODS We examined the correlation between preoperative MARS MRI and surgical findings in a cohort of 20 consecutive patients undergoing revision THA for symptomatic MACC without other associated orthopedic diagnoses. Surgical findings included soft tissue and bone evaluation, presence and location of fluid, abductor disruption, composite tissue damage grade, and prosthesis trunnion damage at the time of revision. RESULTS MARS MRI complex synovitis, thickened pseudocapsule, and extra-articular fluid extension each strongly correlated with both the soft-tissue damage grade and trunnion damage noted at surgery. Bone marrow edema was also found to strongly correlate with bone necrosis intraoperatively. CONCLUSION MARS MRI is an excellent diagnostic tool for evaluation of patients with elevated serum Co after metal-on-polyethylene THA. Patients with complex synovitis, a thick pseudocapsule, bone marrow edema, and extra-articular fluid should strongly consider revision surgery.
Collapse
|
22
|
Jennings JM, Martin JR, Kim RH, Yang CC, Miner TM, Dennis DA. Metal Artifact Reduction Sequence MRI Abnormalities in Asymptomatic Patients with a Ceramic-on-Polyethylene Total Hip Replacement. J Bone Joint Surg Am 2017; 99:593-598. [PMID: 28375892 DOI: 10.2106/jbjs.16.00910] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Magnetic resonance imaging (MRI) is a commonly utilized screening modality in patients with a metal-on-metal (MoM) total hip replacement. The prevalence of clinically important fluid collections may be overestimated since these collections have been reported to occur in asymptomatic patients with MoM and other bearing surfaces. The purpose of this study was to determine the frequency and types of MRI-documented adverse local tissue reactions in asymptomatic patients with a ceramic-on-polyethylene (CoP) total hip replacement. METHODS Forty-four patients (50 hips) with a minimum 2-year follow-up after total hip arthroplasty with CoP implants and a Harris hip score of >90 were enrolled in this study. The inclusion criteria were the absence of hip pain and the availability of appropriate follow-up radiographs. All patients underwent a metal artifact reduction sequence (MARS) MRI scan to determine the presence of fluid collections in asymptomatic patients with a CoP bearing surface. RESULTS Fluid collections were observed in 9 (18%) of 50 asymptomatic hips in this cohort. There were 5 hips with intracapsular synovitis, and 2 of these hips had a thickened synovium. Extra-articular fluid collections with direct intracapsular communication were identified in 4 additional hips. Two of these hips had a thickened synovium. No signs of osteolysis or evidence of adverse local tissue reactions were noted on radiographs at the most recent follow-up. CONCLUSIONS This study revealed that fluid collections are not uncommon after total hip arthroplasty with CoP implants. Synovial thickening may be present and is more prevalent than has been reported in previous studies involving metal-on-polyethylene (MoP) bearing surfaces. The clinical importance and natural history of these findings remain unknown. LEVEL OF EVIDENCE Diagnostic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Jason M Jennings
- 1Colorado Joint Replacement, Denver, Colorado 2Department of Biomedical Engineering, University of Denver, Denver, Colorado 3Department of Orthopedic Surgery, Joan C. Edwards School of Medicine at Marshall University, Huntington, West Virginia 4Department of Orthopedics, University of Colorado School of Medicine, Aurora, Colorado 5Department of Biomedical Engineering, University of Tennessee, Knoxville, Tennessee
| | | | | | | | | | | |
Collapse
|
23
|
Do cobalt and chromium levels predict osteolysis in metal-on-metal total hip arthroplasty? Arch Orthop Trauma Surg 2016; 136:1657-1662. [PMID: 27631309 DOI: 10.1007/s00402-016-2565-y] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/07/2015] [Indexed: 02/09/2023]
Abstract
INTRODUCTION Serum metal ions are part of the regular follow-up routine of patients with metal-on-metal total hip arthroplasties (MoM-THA). Increased cobalt levels have been suggested to indicate implant failure and corrosion. QUESTIONS (1) Is there a correlation between the size of the osteolysis measured on a CT scan and metal ion levels? (2) Can metal ion levels predict the presence of osteolysis in MoM-THA? (3) Are cobalt and chromium serum levels or the cobalt-chromium-ratio diagnostic for osteolysis? MATERIALS AND METHODS CT scans of patients (n = 75) with a unilateral MoM-THA (Birmingham Hip System, Smith & Nephew, TN, USA) implanted by a single surgeon were reviewed to determine the presence of osteolysis. Statistical analysis was performed to detect its association with metal ion levels at the time of the imaging exam. RESULTS The incidence of osteolysis was the same in men and women (35.6 vs 35.7 %). The cobalt-chromium-ratio correlates with the size of the osteolysis on the CT scan and the femoral component size in the overall study population (p = 0.050, p = 0.001) and in men (p = 0.002, p = 0.001) but not in women (p = 0.312, p = 0.344). The AUC for the cobalt-chromium-ratio to detect osteolysis was 0.613 (p = 0.112) for the overall population, 0.710 for men (p = 0.021) and 0.453 (p = 0.684) for women. The data suggest that a cut off level of 1.71 for the cobalt-chromium-ratio has a sensitivity of 62.5 % and specificity of 72.4 % to identify male patients with osteolysis. CONCLUSIONS The disproportional increase of cobalt over chromium, especially in male patients with large component sizes can not be explained by wear alone and suggests that other processes (corrosion) might contribute to metal ion levels and might be more pronounced in patients with larger component sizes.
Collapse
|
24
|
Madanat R, Rolfson O, Donahue GS, Hussey DK, Potter HG, Wallace R, Muratoglu OK, Malchau H. Medial Calcar Erosion Is Associated With Synovial Thickness in Patients With ASR XL Total Hip Arthroplasty. J Arthroplasty 2016; 31:2588-2592. [PMID: 27178012 DOI: 10.1016/j.arth.2016.04.005] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/14/2015] [Revised: 03/30/2016] [Accepted: 04/05/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Medial calcar erosion is considered a late finding in patients with severe adverse local tissue reactions (ALTRs) after total hip arthroplasty (THA) with dual modular neck stems. Although calcar erosion has been associated with dual modular neck stems, one would expect similar findings in standard stems owing to analogous corrosion at the taper junction. The aim of this study was to evaluate whether medial calcar erosion is also associated with ALTR in patients with standard stems in metal-on-metal (MoM) THA. METHODS A total of 96 patients (108 hips) with MoM THA had radiographs and a magnetic resonance imaging of the hip performed at a mean time of 5.7 years after surgery. Calcar erosion was assessed from radiographs. ALTR Anderson grade, diameter, volume, and synovial thickness were assessed from magnetic resonance imaging. RESULTS Calcar erosion was present in 54 hips (50%) and was associated with ALTR synovial thickness but not with Anderson grade, diameter, or volume. Most of the hips with calcar erosion (n = 45) had an ALTR (positive predictive value 0.83, 95% confidence interval 0.70-0.92). The relative risk of having a synovial thickness > 3 mm increased by a factor of 3.0 (95% confidence interval 1.3-6.5) if calcar erosion was observed. CONCLUSION Subtle erosions of the medial calcar after MoM THA may be an early indicator of an adverse reaction to wear particles warranting cross-sectional imaging. Synovial thickness may also be more relevant than absolute size in the classification of ALTR severity and collateral tissue damage.
Collapse
Affiliation(s)
- Rami Madanat
- Harris Orthopaedic Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, Massachusetts; Department of Orthopaedic Surgery, Harvard Medical School, Boston, Massachusetts
| | - Ola Rolfson
- Harris Orthopaedic Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, Massachusetts; Department of Orthopaedic Surgery, Harvard Medical School, Boston, Massachusetts
| | - Gabrielle S Donahue
- Harris Orthopaedic Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, Massachusetts
| | - Daniel K Hussey
- Harris Orthopaedic Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, Massachusetts
| | - Hollis G Potter
- Department of Radiology and Imaging, Hospital for Special Surgery, New York, New York
| | - Robert Wallace
- Department of Orthopaedic Surgery, Sportsmed.SA, Stepney, South Australia
| | - Orhun K Muratoglu
- Harris Orthopaedic Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, Massachusetts; Department of Orthopaedic Surgery, Harvard Medical School, Boston, Massachusetts
| | - Henrik Malchau
- Harris Orthopaedic Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, Massachusetts; Department of Orthopaedic Surgery, Harvard Medical School, Boston, Massachusetts
| |
Collapse
|
25
|
Barlow BT, Ortiz PA, Fields KG, Burge AJ, Potter HG, Westrich GH. Magnetic Resonance Imaging Predicts Adverse Local Tissue Reaction Histologic Severity in Modular Neck Total Hip Arthroplasty. J Arthroplasty 2016; 31:2325-31. [PMID: 27118350 DOI: 10.1016/j.arth.2016.03.022] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/11/2016] [Revised: 03/10/2016] [Accepted: 03/11/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The association between advanced imaging, serum metal ion levels, and histologic adverse local tissue reaction (ALTR) severity has not been previously reported for Rejuvenate modular neck femoral stems. METHODS A cohort of 90 patients with 98 Rejuvenate modular neck femoral stems was revised by a single surgeon from July 2011 to December 2014. Before revision, patients underwent multiacquisition variable resonance image combination sequence magnetic resonance imaging (MRI), and serum cobalt and chromium ion levels were measured. Histologic samples from the revision surgery were scored for synovial lining, inflammatory infiltrate, and tissue organization as proposed by Campbell. Regression based on the generalized estimating equations approach was used to assess the univariate association between each MRI, demographic, and metal ion measure and ALTR severity while accounting for the correlation between bilateral hips. Random forest analysis was then used to determine the relative importance of MRI characteristics, demographics, and metal ion levels in predicting ALTR severity. RESULTS Synovial thickness as measured on MRI was found to be the strongest predictor of ALTR histologic severity in a recalled modular neck femoral stem. CONCLUSION MRI can accurately describe ALTR in modular femoral neck total hip arthroplasty. MRI characteristics, particularly maximal synovial thickness and synovitis volume, predicted histologic severity. Serum metal ion levels do not correlate with histologic severity in Rejuvenate modular neck total hip arthroplasty.
Collapse
Affiliation(s)
- Brian T Barlow
- Division of Adult Reconstruction and Joint Replacement Surgery, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, New York
| | - Philippe A Ortiz
- Division of Adult Reconstruction and Joint Replacement Surgery, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, New York
| | - Kara G Fields
- Epidemiology and Biostatistics Core, Hospital for Special Surgery, New York, New York
| | - Alissa J Burge
- Department of Radiology and Imaging, Hospital for Special Surgery, New York, New York
| | - Hollis G Potter
- Department of Radiology and Imaging, Hospital for Special Surgery, New York, New York
| | - Geoffrey H Westrich
- Division of Adult Reconstruction and Joint Replacement Surgery, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, New York
| |
Collapse
|
26
|
Blum A, Gondim-Teixeira P, Gabiache E, Roche O, Sirveaux F, Olivier P, Coudane H, Raymond A, Louis M, Grandhaye M, Meyer JB, Mainard D, Molé D. Developments in imaging methods used in hip arthroplasty: A diagnostic algorithm. Diagn Interv Imaging 2016; 97:735-47. [PMID: 27452630 DOI: 10.1016/j.diii.2016.07.001] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2016] [Accepted: 07/01/2016] [Indexed: 01/26/2023]
Abstract
BACKGROUND Several imaging modalities can be used to diagnose complications of hip prosthesis placement. Despite progress in these imaging techniques, there are, as yet, no guidelines as to their respective indications. METHODS We formed a panel of experts in fields related to prosthesis imaging (radiology, nuclear medicine, orthopedic surgery) and conducted a review of the literature to determine the value of each modality for diagnosing complications following hip replacement. RESULTS Few recent studies have investigated the benefits related to the use of the latest technical developments, and studies comparing different methods are extremely rare. CONCLUSIONS We have developed a diagnostic tree based on the characteristics of each imaging technique and recommend its use. Computed topography was found to be the most versatile and cost-effective imaging solution and therefore a key tool for diagnosing the complications of hip replacement surgery.
Collapse
Affiliation(s)
- A Blum
- Service d'imagerie Guilloz, CHU de Nancy, avenue de Maréchal-de-Lattre-de-Tassigny, 54035 Nancy, France.
| | - P Gondim-Teixeira
- Service d'imagerie Guilloz, CHU de Nancy, avenue de Maréchal-de-Lattre-de-Tassigny, 54035 Nancy, France.
| | - E Gabiache
- Service de médecine nucléaire, CHU de Nancy, rue du Morvan, 54511 Vandœuvre-lès-Nancy cedex, France.
| | - O Roche
- Centre chirurgical Émile-Gallé, 49, rue Hermite, 54000 Nancy, France.
| | - F Sirveaux
- Centre chirurgical Émile-Gallé, 49, rue Hermite, 54000 Nancy, France.
| | - P Olivier
- Service de médecine nucléaire, CHU de Nancy, rue du Morvan, 54511 Vandœuvre-lès-Nancy cedex, France.
| | - H Coudane
- Chirurgie traumatologique et arthroscopique de l'appareil locomoteur (ATOL), CHU de Nancy, avenue de Maréchal-de-Lattre-de-Tassigny, 54035 Nancy, France.
| | | | - A Raymond
- Service d'imagerie Guilloz, CHU de Nancy, avenue de Maréchal-de-Lattre-de-Tassigny, 54035 Nancy, France.
| | - M Louis
- Service d'imagerie Guilloz, CHU de Nancy, avenue de Maréchal-de-Lattre-de-Tassigny, 54035 Nancy, France.
| | - M Grandhaye
- Service d'imagerie Guilloz, CHU de Nancy, avenue de Maréchal-de-Lattre-de-Tassigny, 54035 Nancy, France.
| | - J-B Meyer
- Service d'imagerie Guilloz, CHU de Nancy, avenue de Maréchal-de-Lattre-de-Tassigny, 54035 Nancy, France.
| | - D Mainard
- Chirurgie orthopédique et traumatologique (COT), CHU de Nancy, avenue de Maréchal-de-Lattre-de-Tassigny, 54035 Nancy, France.
| | - D Molé
- Centre chirurgical Émile-Gallé, 49, rue Hermite, 54000 Nancy, France.
| |
Collapse
|
27
|
The Prevalence of Positive Findings on Metal Artifact Reduction Sequence Magnetic Resonance Imaging in Metal-on-Metal Total Hip Arthroplasty. J Arthroplasty 2016; 31:1519-23. [PMID: 26876943 DOI: 10.1016/j.arth.2016.01.011] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/26/2015] [Revised: 12/28/2015] [Accepted: 01/13/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND We sought to assess the prevalence of soft tissue changes seen on magnetic resonance imaging (MRI) after metal-on-metal (MOM) total hip arthroplasty (THA) and determine if the presence of pseudotumors was associated with metal ion levels, acetabular cup position, outcomes scores, and femoral head size. METHODS After receiving an institutional review board exemption for secondary data analysis, we performed a cross-sectional study identifying 55 patients (55 hips) that underwent primary THA with a MOM articulation and had subsequent MRI imaging between February 2013 and February 2014 at a single academic medical center. RESULTS Twenty-four patients (44%) had no evidence of pseudotumors, 27 (49%) had type I pseudotumors, and 4 (7%) were classified as having type II pseudotumors. The presence and severity of pseudotumors were associated with higher serum chromium levels (P = .043). Neither acetabular inclination nor acetabular version was associated with the presence of pseudotumors, the severity of pseudotumors, or elevated serum metal ion levels (all P > .05). Increased metal ion levels were associated with lower Harris Hip Score and higher Harris Hip Score pain subscores (all P < .05). CONCLUSION In conclusion, pseudotumors on metal artifact reduction sequencing MRI may be present in both symptomatic and asymptomatic MOM THAs. Surgeons should therefore exercise caution in placing too much emphasis on isolated studies such as cross-sectional imaging. Instead, a structured approach to evaluation of MOM arthroplasty should be followed.
Collapse
|
28
|
Chalmers BP, Perry KI, Taunton MJ, Mabry TM, Abdel MP. Diagnosis of adverse local tissue reactions following metal-on-metal hip arthroplasty. Curr Rev Musculoskelet Med 2016; 9:67-74. [PMID: 26816329 PMCID: PMC4762796 DOI: 10.1007/s12178-016-9321-3] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Metal-on-metal (MOM) bearing surfaces in hip arthroplasty have distinct advantages that led to the increase in popularity in North America in the early 2000s. However, with their increased use, concerns such as local cytotoxicity and hypersensitivity reactions leading to soft tissue damage and cystic mass formation (known collectively as adverse local tissue reactions (ALTR)) became apparent. The clinical presentation of ALTR is highly variable. The diagnosis of ALTR in MOM articulations in hip arthroplasty can be challenging and a combination of clinical presentation, physical examination, implant track record, component positioning, serum metal ion levels, cross-sectional imaging, histopathologic analysis, and consideration of alternative diagnoses are essential.
Collapse
Affiliation(s)
- Brian P Chalmers
- Department of Orthopedic Surgery, Mayo Clinic, 200 First Street S.W, Rochester, MN, 55905, USA.
| | - Kevin I Perry
- Department of Orthopedic Surgery, Mayo Clinic, 200 First Street S.W, Rochester, MN, 55905, USA.
| | - Michael J Taunton
- Department of Orthopedic Surgery, Mayo Clinic, 200 First Street S.W, Rochester, MN, 55905, USA.
| | - Tad M Mabry
- Department of Orthopedic Surgery, Mayo Clinic, 200 First Street S.W, Rochester, MN, 55905, USA.
| | - Matthew P Abdel
- Department of Orthopedic Surgery, Mayo Clinic, 200 First Street S.W, Rochester, MN, 55905, USA.
| |
Collapse
|
29
|
Reito A, Lainiala O, Elo P, Eskelinen A. Prevalence of Failure due to Adverse Reaction to Metal Debris in Modern, Medium and Large Diameter Metal-on-Metal Hip Replacements--The Effect of Novel Screening Methods: Systematic Review and Metaregression Analysis. PLoS One 2016; 11:e0147872. [PMID: 26930057 PMCID: PMC4773181 DOI: 10.1371/journal.pone.0147872] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2015] [Accepted: 11/25/2015] [Indexed: 11/18/2022] Open
Abstract
Metal-on-metal (MoM) hip replacements were used for almost a decade before adverse reactions to metal debris (ARMD) were found to be a true clinical problem. Currently, there is a paucity of evidence regarding the usefulness of systematic screening for ARMD. We implemented a systematic review and meta-analysis to establish the prevalence of revision confirmed ARMD stratified by the use of different screening protocols in patients with MoM hip replacements. Five levels of screening were identified: no screening (level 0), targeted blood metal ion measurement and/or cross-sectional imaging (level 1), metal ion measurement without imaging (level 2), metal ion measurement with targeted imaging (level 3) and comprehensive screening (both metal ions and imaging for all; level 4). 122 studies meeting our eligibility criteria were included in analysis. These studies included 144 study arms: 100 study arms with hip resurfacings, 33 study arms with large-diameter MoM total hip replacements (THR), and 11 study arms with medium-diameter MoM THRs. For hip resurfacing, the lowest prevalence of ARMD was seen with level 0 screening (pooled prevalence 0.13%) and the highest with level 4 screening (pooled prevalace 9.49%). Pooled prevalence of ARMD with level 0 screening was 0.29% and with level 4 screening 21.3% in the large-diameter MoM THR group. In metaregression analysis of hip resurfacings, level 4 screening was superior with regard to prevalence of ARMD when compared with other levels. In the large diameter THR group level 4 screening was superior to screening 0,2 and 3. These outcomes were irrespective of follow-up time or study publication year. With hip resurfacings, routine cross-sectional imaging regardless of clinical findings is advisable. It is clear, however, that targeted metal ion measurement and/or imaging is not sufficient in the screening for ARMD in any implant concepts. However, economic aspects should be weighed when choosing the preferred screening level.
Collapse
Affiliation(s)
- Aleksi Reito
- Coxa Hospital for Joint Replacement, Biokatu 6b, 33900 Tampere, Finland
- * E-mail:
| | - Olli Lainiala
- Coxa Hospital for Joint Replacement, Biokatu 6b, 33900 Tampere, Finland
| | - Petra Elo
- Coxa Hospital for Joint Replacement, Biokatu 6b, 33900 Tampere, Finland
| | - Antti Eskelinen
- Coxa Hospital for Joint Replacement, Biokatu 6b, 33900 Tampere, Finland
| |
Collapse
|
30
|
Reito A, Elo P, Nieminen J, Puolakka T, Eskelinen A. Gluteal muscle fatty atrophy is not associated with elevated blood metal ions or pseudotumors in patients with a unilateral metal-on-metal hip replacement. Acta Orthop 2016; 87:29-35. [PMID: 26427902 PMCID: PMC4940588 DOI: 10.3109/17453674.2015.1094713] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/08/2015] [Accepted: 07/22/2015] [Indexed: 01/31/2023] Open
Abstract
BACKGROUND AND PURPOSE There are no international guidelines to define adverse reaction to metal debris (ARMD). Muscle fatty atrophy has been reported to be common in patients with failing metal-on-metal (MoM) hip replacements. We assessed whether gluteal muscle fatty atrophy is associated with elevated blood metal ion levels and pseudotumors. PATIENTS AND METHODS 263 consecutive patients with unilateral ASR XL total hip replacement using a posterior approach and with an unoperated contralateral hip were included in the study. All patients had undergone a standard screening program at our institution, including MRI and blood metal ion measurement. Muscle fatty atrophy was graded as being absent, mild, moderate, or severe in each of the gluteal muscles. RESULTS The prevalence of moderate-to-severe gluteal muscle atrophy was low (12% for gluteus minimus, 10% for gluteus medius, and 2% for gluteus maximus). Muscle atrophy was neither associated with elevated blood metal ion levels (> 5 ppb) nor with the presence of a clear (solid- or mixed-type) pseudotumor seen in MRI. A combination of moderate-to-severe atrophy in MRI, elevated blood metal ion levels, and MRI-confirmed mixed or solid pseudotumor was rare. Multivariable regression revealed that "preoperative diagnosis other than osteoarthrosis" was the strongest predictor of the presence of fatty atrophy. INTERPRETATION Gluteal muscle atrophy may be a clinically significant finding with influence on hip muscle strength in patients with MoM hip replacement. However, our results suggest that gluteal muscle atrophy seen in MRI is not associated with either the presence or severity of ARMD, at least not in patients who have been operated on using the posterior approach.
Collapse
Affiliation(s)
- Aleksi Reito
- Coxa Hospital for Joint Replacement, Tampere, Finland.
| | | | | | | | | |
Collapse
|
31
|
Madanat R, Hussey DK, Donahue GS, Potter HG, Wallace R, Bragdon C, Muratoglu O, Malchau H. Early Lessons From a Worldwide, Multicenter, Followup Study of the Recalled Articular Surface Replacement Hip System. Clin Orthop Relat Res 2016; 474:166-74. [PMID: 26310677 PMCID: PMC4686517 DOI: 10.1007/s11999-015-4456-x] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/12/2015] [Accepted: 07/07/2015] [Indexed: 02/08/2023]
Abstract
BACKGROUND Adverse local tissue reactions (ALTRs) around hip arthroplasties are an important reason for failure of metal-on-metal (MoM) hip implants. Little is known about capsular dehiscence patterns as ALTRs decompress from the hip into the surrounding tissue planes; these patterns may also influence the onset and severity of patient symptoms. QUESTIONS/PURPOSES Through a multicenter study approach, we asked: (1) Is ALTR location related to the surgical approach used for arthroplasty in patients who underwent hip arthroplasty (resurfacing or THA) with a single, recalled hip arthroplasty system? (2) Do ALTR severity and location affect patient-reported outcomes in these patients? (3) Is ALTR severity different between patients who received the resurfacing version of this component (Articular Surface Replacement [ASR]) and those who received the THA implant in this system (ASR XL)? METHODS In a multicenter prospective study of patients who had undergone surgery with use of the ASR and ASR XL hip system (DePuy Orthopaedics, Warsaw, IN, USA), 288 patients (333 hips) from two centers had a metal artifact reduction sequence MRI of the hip performed at a mean time of 6 years postsurgery. Procedures included 166 hips (50%) with ASR resurfacing and 167 hips (50%) with ASR XL THA performed between 2004 and 2010. One hundred twenty-nine hips (39%) had been operated on using a direct lateral approach and 204 using a posterior approach (61%). The EQ-5D, Harris hip score, UCLA activity score, and visual analog scale pain score were obtained for each patient. ALTRs were classified using the Anderson ALTR grading system, and the location, synovial thickness, and diameter of the ATLRs were assessed. The relationship between ALTR location and surgical approach as well as for ALTR severity and patient-reported outcomes were evaluated, and logistic regression was used to identify predictors for moderate-to-severe ALTRs. RESULTS Moderate or severe ALTRs were identified in 79 hips (24%); 41 of these hips had been operated on using the direct lateral approach and 38 using the posterior approach. In patients in whom the lateral approach was used, 83% had an anterior ALTR. Similarly, 71% of patients in the posterior approach group had posterior ALTRs. There were no differences in patient-reported outcome measures between patients with moderate-to-severe ALTRs and those with no ALTR findings on MRI (p > 0.09). Use of ASR XL was an independent risk factor for moderate-to-severe ALTRs (odds ratio, 2.8; 95% confidence interval, 1.4-5.5 p = 0.004) and patients with ASR XL also had a thicker synovium (median ASR XL = 3.6 mm [1.2-10.6 mm], median ASR = 2.6 mm [1.2-10.7 mm], p < 0.001) and larger maximal ALTR diameter (median ASR XL = 47.6 mm [14-109.70 mm], median ASR = 38.4 [17.2-118.0 mm], p = 0.02) than patients treated with ASR. CONCLUSIONS The location of ALTRs can be predicted based on the previous surgical approach to the hip. Patients with ASR XL are more likely to develop moderate-to-severe ALTRs compared with ASR patients. An extensive range of patient-reported outcome measures may not identify all patients with ALTRs further supporting the use of MRI as a screening measure for ALTRs. LEVEL OF EVIDENCE Level II, therapeutic study.
Collapse
Affiliation(s)
- Rami Madanat
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, 55 Fruit Street, GRJ 1231, Boston, MA, 02114, USA
| | - Daniel K Hussey
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, 55 Fruit Street, GRJ 1231, Boston, MA, 02114, USA
| | - Gabrielle S Donahue
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, 55 Fruit Street, GRJ 1231, Boston, MA, 02114, USA
| | - Hollis G Potter
- Department of Radiology and Imaging, Hospital for Special Surgery, New York, NY, USA
| | | | - Charles Bragdon
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, 55 Fruit Street, GRJ 1231, Boston, MA, 02114, USA
| | - Orhun Muratoglu
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, 55 Fruit Street, GRJ 1231, Boston, MA, 02114, USA
| | - Henrik Malchau
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, 55 Fruit Street, GRJ 1231, Boston, MA, 02114, USA.
| |
Collapse
|
32
|
Abstract
Hip arthroplasty has become the standard treatment for end-stage hip disease, allowing pain relief and restoration of mobility in large numbers of patients; however, pain after hip arthroplasty occurs in as many as 40% of cases, and despite improved longevity, all implants eventually fail with time. Owing to the increasing numbers of hip arthroplasty procedures performed, the demographic factors, and the metal-on-metal arthroplasty systems with their associated risk for the development of adverse local tissue reactions to metal products, there is a growing demand for an accurate diagnosis of symptoms related to hip arthroplasty implants and for a way to monitor patients at risk. Magnetic resonance (MR) imaging has evolved into a powerful diagnostic tool for the evaluation of hip arthroplasty implants. Optimized conventional pulse sequences and metal artifact reduction techniques afford improved depiction of bone, implant-tissue interfaces, and periprosthetic soft tissue for the diagnosis of arthroplasty-related complications. Strategies for MR imaging of hip arthroplasty implants are presented, as well as the imaging appearances of common causes of painful and dysfunctional hip arthroplasty systems, including stress reactions and fractures; bone resorption and aseptic loosening; polyethylene wear-induced synovitis and osteolysis; adverse local tissue reactions to metal products; infection; heterotopic ossification; tendinopathy; neuropathy; and periprosthetic neoplasms. A checklist is provided for systematic evaluation of MR images of hip arthroplasty implants. MR imaging with optimized conventional pulse sequences and metal artifact reduction techniques is a comprehensive imaging modality for the evaluation of the hip after arthroplasty, contributing important information for diagnosis, prognosis, risk stratification, and surgical planning.
Collapse
Affiliation(s)
- Jan Fritz
- From the Department of Radiology and Imaging, Hospital for Special Surgery, 535 E 70th St, New York, NY 10021
| | | | | | | |
Collapse
|
33
|
Boas RDMSV, Madeira IA, Lopes AA, Paiva EB, Rodrigues AS. Inflammatory pseudotumor of the hip: a complication of arthroplasty to be recognized by the radiologist. Radiol Bras 2015; 48:314-8. [PMID: 26543283 PMCID: PMC4633076 DOI: 10.1590/0100-3984.2013.0005] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Soft tissue complications following hip arthroplasty may occur either in cases of
total hip arthroplasty or in hip resurfacing, a technique that has become popular in
cases involving young patients. Both orthopedic and radiological literatures are now
calling attention to these symptomatic periprosthetic soft tissue masses called
inflammatory pseudotumors or aseptic lymphocytic vasculites-associated lesions.
Pseudotumors are associated with pain, instability, neuropathy, and premature
loosening of prosthetic components, frequently requiring early and difficult
reoperation. Magnetic resonance imaging plays a relevant role in the evaluation of
soft tissue changes in the painful hip after arthroplasty, ranging from early
periprosthetic fluid collections to necrosis and more extensive tissue damage.
Collapse
Affiliation(s)
- Raquel de Melo Santos Vilas Boas
- Titular Members of Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR), MDs, Radiologists at Clínica Axial Medicina Diagnóstica, Belo Horizonte, MG, Brazil
| | - Ivana Andrade Madeira
- Titular Members of Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR), MDs, Radiologists at Clínica Axial Medicina Diagnóstica, Belo Horizonte, MG, Brazil
| | - Alexia Abuhid Lopes
- Titular Member of Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR), MD, Radiologist, Specialist in Musculoskeletal System Imaging at Clínica Axial Medicina Diagnóstica, Belo Horizonte, MG, Brazil
| | - Edson Barreto Paiva
- Titular Members of Sociedade Brasileira de Quadril and Sociedade Brasileira de Ortopedia e Traumatologia, Hip Surgeons at Hospital das Clínicas - Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG, Brazil
| | - André Soares Rodrigues
- Titular Members of Sociedade Brasileira de Quadril and Sociedade Brasileira de Ortopedia e Traumatologia, Hip Surgeons at Hospital das Clínicas - Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG, Brazil
| |
Collapse
|
34
|
Madanat R, Hussey DK, Donahue GS, Potter HG, Wallace R, Bragdon CR, Muratoglu OK, Malchau H. The Symmetry of Adverse Local Tissue Reactions in Patients with Bilateral Simultaneous and Sequential ASR Hip Replacement. J Arthroplasty 2015; 30:1794-8. [PMID: 26055146 DOI: 10.1016/j.arth.2015.04.036] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/10/2015] [Revised: 04/13/2015] [Accepted: 04/27/2015] [Indexed: 02/01/2023] Open
Abstract
The purpose of this study was to evaluate whether patients with bilateral metal-on-metal (MoM) hip replacements have symmetric adverse local tissue reactions (ALTRs) at follow-up. An MRI of both hips was performed at a mean time of six years after surgery in 43 patients. The prevalence and severity of ALTRs were found to be similar in simultaneous hips but differences were observed in sequential hips. The order and timing of sequential hip arthroplasties did not affect the severity of ALTRs. Thus, in addition to metal ion exposure from an earlier MoM implant other factors may also play a role in the progression of ALTRs. Bilateral implants should be given special consideration in risk stratification algorithms for management of patients with MoM hip arthroplasty.
Collapse
Affiliation(s)
- Rami Madanat
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts; Harvard Medical School, Department of Orthopaedic Surgery, Boston, Massachusetts
| | - Daniel K Hussey
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts
| | - Gabrielle S Donahue
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts
| | - Hollis G Potter
- Department of Radiology and Imaging, Hospital for Special Surgery, New York, New York
| | | | - Charles R Bragdon
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts; Harvard Medical School, Department of Orthopaedic Surgery, Boston, Massachusetts
| | - Orhun K Muratoglu
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts; Harvard Medical School, Department of Orthopaedic Surgery, Boston, Massachusetts
| | - Henrik Malchau
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts; Harvard Medical School, Department of Orthopaedic Surgery, Boston, Massachusetts
| |
Collapse
|
35
|
In Vitro Analyses of the Toxicity, Immunological, and Gene Expression Effects of Cobalt-Chromium Alloy Wear Debris and Co Ions Derived from Metal-on-Metal Hip Implants. LUBRICANTS 2015. [DOI: 10.3390/lubricants3030539] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
36
|
Lim D, Jeremiah C, Altuntas A, Sinnappu R, O'Sullivan R, Lim WK. Pseudotumor After Metal-on-Metal Hip Arthroplasty. J Am Geriatr Soc 2015; 63:1274-6. [PMID: 26096417 DOI: 10.1111/jgs.13498] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Affiliation(s)
- David Lim
- Austin Hospital, Melbourne, Victoria, Australia
| | | | - Altay Altuntas
- Northern Hospital, Melbourne, Victoria, Australia.,St Vincent's Hospital, Melbourne, Victoria, Australia.,University of Melbourne, Melbourne, Victoria, Australia
| | | | - Richard O'Sullivan
- Epworth Hospital, Melbourne, Victoria, Australia.,Monash University, Melbourne, Victoria, Australia
| | - Wen Kwang Lim
- Northern Hospital, Melbourne, Victoria, Australia.,University of Melbourne, Melbourne, Victoria, Australia
| |
Collapse
|
37
|
Berber R, Khoo M, Cook E, Guppy A, Hua J, Miles J, Carrington R, Skinner J, Hart A. Muscle atrophy and metal-on-metal hip implants: a serial MRI study of 74 hips. Acta Orthop 2015; 86:351-7. [PMID: 25588091 PMCID: PMC4443469 DOI: 10.3109/17453674.2015.1006981] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
BACKGROUND AND PURPOSE Muscle atrophy is seen in patients with metal-on-metal (MOM) hip implants, probably because of inflammatory destruction of the musculo-tendon junction. However, like pseudotumors, it is unclear when atrophy occurs and whether it progresses with time. Our objective was to determine whether muscle atrophy associated with MOM hip implants progresses with time. PATIENTS AND METHODS We retrospectively reviewed 74 hips in 56 patients (32 of them women) using serial MRI. Median age was 59 (23-83) years. The median time post-implantation was 83 (35-142) months, and the median interval between scans was 11 months. Hip muscles were scored using the Pfirrmann system. The mean scores for muscle atrophy were compared between the first and second MRI scans. Blood cobalt and chromium concentrations were determined. RESULTS The median blood cobalt was 6.84 (0.24-90) ppb and median chromium level was 4.42 (0.20-45) ppb. The median Oxford hip score was 34 (5-48). The change in the gluteus minimus mean atrophy score between first and second MRI was 0.12 (p = 0.002). Mean change in the gluteus medius posterior portion (unaffected by surgical approach) was 0.08 (p = 0.01) and mean change in the inferior portion was 0.10 (p = 0.05). Mean pseudotumor grade increased by 0.18 (p = 0.02). INTERPRETATION Worsening muscle atrophy and worsening pseudotumor grade occur over a 1-year period in a substantial proportion of patients with MOM hip implants. Serial MRI helps to identify those patients who are at risk of developing worsening soft-tissue pathology. These patients should be considered for revision surgery before irreversible muscle destruction occurs.
Collapse
Affiliation(s)
- Reshid Berber
- Royal National Orthopaedic Hospital, Brockley Hill, Stanmore, Middlesex
| | - Michael Khoo
- Royal National Orthopaedic Hospital, Brockley Hill, Stanmore, Middlesex
| | - Erica Cook
- University of Bedfordshire,Park Square, Luton, Bedfordshire
| | - Andrew Guppy
- University of Bedfordshire,Park Square, Luton, Bedfordshire
| | - Jia Hua
- Royal National Orthopaedic Hospital, Brockley Hill, Stanmore, Middlesex,Middlesex University London, The Burroughs, London, UK
| | - Jonathan Miles
- Royal National Orthopaedic Hospital, Brockley Hill, Stanmore, Middlesex
| | | | - John Skinner
- Royal National Orthopaedic Hospital, Brockley Hill, Stanmore, Middlesex
| | - Alister Hart
- Royal National Orthopaedic Hospital, Brockley Hill, Stanmore, Middlesex
| |
Collapse
|
38
|
Pownder SL, Koff MF, Shah PH, Fortier LA, Potter HG. Magnetic resonance imaging of an equine fracture model containing stainless steel metal implants. Equine Vet J 2015; 48:321-5. [PMID: 25627908 DOI: 10.1111/evj.12424] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2014] [Accepted: 01/25/2015] [Indexed: 12/24/2022]
Abstract
REASONS FOR PERFORMING STUDY Post operative imaging in subjects with orthopaedic implants is challenging across all modalities. Magnetic resonance imaging (MRI) is preferred to assess human post operative musculoskeletal complications, as soft tissue and bones are evaluated without using ionising radiation. However, with conventional MRI pulse sequences, metal creates susceptibility artefact that distorts anatomy. Assessment of the post operative equine patient is arguably more challenging due to the volume of metal present, and MRI is often not performed in horses with implants. Novel pulse sequences such as multiacquisition variable resonance image combination (MAVRIC) now provide improved visibility in the vicinity of surgical-grade implants and offer an option for imaging horses with metal implants. OBJECTIVES To compare conspicuity of regional anatomy in an equine fracture-repair model using MAVRIC, narrow receiver bandwidth (NBW) fast spin echo (FSE), and wide receiver bandwidth (WBW) FSE sequences. STUDY DESIGN Nonrandomised in vitro experiment. METHODS MAVRIC, NBW FSE and WBW FSE were performed on 9 cadaveric distal limbs with fractures and stainless steel implants in the third metacarpal bone and proximal phalanx. Objective measures of artefact reduction were performed by calculating the total artefact area in each transverse image as a percentage of the total anatomic area. The number of transverse images in which fracture lines were visible was tabulated for each sequence. Regional soft tissue conspicuity was assessed subjectively. RESULTS Overall anatomic delineation was improved using MAVRIC compared with NBW FSE; delineation of structures closest to the metal implants was improved using MAVRIC compared with WBW FSE and NBW FSE. Total artefact area was the highest for NBW FSE and lowest for MAVRIC; the total number of transverse slices with a visible fracture line was highest in MAVRIC and lowest in NBW FSE. CONCLUSION MAVRIC and WBW FSE are feasible additions to minimise artefact around implants.
Collapse
Affiliation(s)
- S L Pownder
- MRI Laboratory, Hospital for Special Surgery, New York, USA
| | - M F Koff
- MRI Laboratory, Hospital for Special Surgery, New York, USA
| | - P H Shah
- MRI Laboratory, Hospital for Special Surgery, New York, USA
| | - L A Fortier
- Department of Clinical Sciences, Cornell University College of Veterinary Medicine, Ithaca, New York, USA
| | - H G Potter
- MRI Laboratory, Hospital for Special Surgery, New York, USA
| |
Collapse
|
39
|
Metal artifact reduction with MAVRIC SL at 3-T MRI in patients with hip arthroplasty. AJR Am J Roentgenol 2015; 204:140-7. [PMID: 25539249 DOI: 10.2214/ajr.13.11785] [Citation(s) in RCA: 50] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
OBJECTIVE The objective of our study was to compare the multiacquisition variable-resonance image combination selective (MAVRIC SL) sequence with the 2D fast spin-echo (FSE) sequence for metal artifact reduction on 3-T MRI in patients with hip arthroplasty (HA). MATERIALS AND METHODS Matched 2D FSE and MAVRIC SL images of 21 hips (19 patients with HA) were included in the study group. Paired image sets, composed of 13 coronal and 12 axial slices (total, 25 image sets), of the 21 hips were evaluated. For quantitative analysis, the artifact area was measured at the level of the hip and femur. For qualitative analysis, two musculoskeletal radiologists independently compared paired 2D FSE and MAVRIC SL sets in terms of artifacts, depiction of anatomic detail, level of diagnostic confidence, and detection of abnormal findings. RESULTS The measured artifact area was significantly smaller (p < 0.05) on MAVRIC SL than 2D FSE at both the level of hip (59.9% reduction with MAVRIC SL) and femur (31.3% reduction with MAVRIC SL). The artifact score was also significantly decreased (p < 0.0001) with MAVRIC SL compared with 2D FSE for both reviewers. The hip joint capsule and the muscle and tendon attachment sites of the obturator externus and iliopsoas muscles were better depicted with MAVRIC SL than 2D FSE (p < 0.0125). Abnormal findings were significantly better shown on MAVRIC SL imaging compared with 2D FSE imaging (p < 0.0001). CONCLUSION The MAVRIC SL sequence can significantly reduce metal artifact on 3-T MRI compared with the 2D FSE sequence and can increase diagnostic confidence of 3-T MRI in patients with total HA.
Collapse
|
40
|
Abstract
Wear and corrosion in joint arthroplasty are important causes of failure. From the standpoint of current clinical importance, there are four main categories of wear and tribocorrosion: polyethylene wear, ceramic-on-ceramic (CoC) bearing wear, metal-on-metal (MoM) bearing wear, and taper tribocorrosion. Recently, problems with wear in the knee have become less prominent as have many issues with hip polyethylene (PE) bearings resulting from the success of crosslinked PE. However, MoM articulations and taper tribocorrosion have been associated with soft tissue inflammatory responses, and as a result, they have become prominent clinical concerns. WHERE ARE WE NOW?: For PE wear in the hip, several advances include improved locking mechanisms and data supporting highly crosslinked polyethylenes (HXLPE). Edge-loading in CoC articulations can contribute to stripe wear and subsequent squeaking. For MoM articulations, the relationship of wear-to-edge loading, sensitivity to component positioning, typical soft tissue response, and use of imaging is increasingly understood. Taper tribocorrosion (from femoral head-neck junctions and other modular elements) and associated soft tissue inflammatory responses appear to be serious clinical issues that are not fully understood. WHERE DO WE NEED TO GO?: In the knee, clinical concerns remain with the efficacy of HXLPE, modular connections, and metal allergies. For PE wear in the hip, concerns remain regarding how to increase crosslinking of PE while minimizing PE fractures. With CoC articulations, questions remain on how to prevent noises, chipping, and impingement and if enhanced designs can contribute to improved results. For MoM articulations, we need to improve imaging tests for soft tissue reactions, determine best practices in terms of monitoring protocols, and better define if, how, and when to act on serum metal levels. For taper tribocorrosion, we need to use modularity wisely and also understand how to improve tapers and materials in the future. For patients at risk for tribocorrosion, we need to define realistic diagnostic and monitoring protocols. We also need to enhance revision methods, and the threshold of acceptable soft tissue damage, to minimize complications associated with soft tissue damage such as hip instability. HOW DO WE GET THERE?: HXLPE and other bearing surfaces will likely continue to be refined. We need to develop tapers with more resistance to tribocorrosion through improved understanding of the manufacturing process and ongoing engineering improvements. Revision procedures for wear and tribocorrosion can be enhanced by determining when partial component retention is appropriate and how best to manage soft tissue damage. For CoC articulations, enhanced designs are required to minimize noises, chipping, and impingement. Importantly, we must continue to promote and analyze joint replacement registries to identify early failures and analyze long-term successes.
Collapse
|
41
|
Reito A, Elo P, Puolakka T, Pajamäki J, Nieminen J, Eskelinen A. Repeated magnetic resonance imaging in 154 hips with large-diameter metal-on-metal hip replacement. Acta Orthop 2014; 85:570-6. [PMID: 25238435 PMCID: PMC4259038 DOI: 10.3109/17453674.2014.961868] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/18/2014] [Accepted: 06/02/2014] [Indexed: 01/31/2023] Open
Abstract
BACKGROUND AND PURPOSE The US Food and Drug Administration and the UK Medicines and Health Regulation Agency recommend using MRI in the evaluation of patients with large-diameter metal-on-metal (LD-MoM) hips. Such recommendations do not take into account the relevance of repeated cross-sectional imaging. We therefore investigated the natural course of pseudotumors in patients with LD-MoM hip replacements. PATIENTS AND METHODS Of 888 ASR patients (1,036 hips) 674 patients (798 hips) underwent 2 follow-up visits at our institution. Of these, we identified 124 patients (154 hips) who had undergone repeated clinical assessment including MRI and whole-blood metal ion assessment. RESULTS A change in classification in imaging findings between the 2 MRIs was seen in 17 of the 154 hips (11%). In 13 hips (8%), a significant progression of the pseudotumor was evident, while in 4 (3 %) there was a retrogressive change. 10 of these 13 hips had had a normal first MRI. Patients with a progressive change in the scans did not differ significantly from those without a change in MRI classification regarding follow-up time, time interval between MRIs, or changes in whole-blood Cr and Co levels between assessments. INTERPRETATION A change in classification was rare, considering that all patients had a clinical indication for repeated imaging. Progression of the findings did not appear to correlate clearly with symptoms or whole-blood metal values.
Collapse
Affiliation(s)
- Aleksi Reito
- Coxa Hospital for Joint Replacement , Tampere , Finland
| | | | | | | | | | | |
Collapse
|
42
|
Robinson E, Henckel J, Sabah S, Satchithananda K, Skinner J, Hart A. Cross-sectional imaging of metal-on-metal hip arthroplasties. Can we substitute MARS MRI with CT? Acta Orthop 2014; 85:577-84. [PMID: 25267500 PMCID: PMC4259024 DOI: 10.3109/17453674.2014.964618] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
BACKGROUND AND PURPOSE Metal artifact reduction sequence (MARS) MRI is widely advocated for surveillance of metal-on-metal hip arthroplasties (MOM-HAs). However, its use is limited by susceptibility artifact at the prosthesis-bone interface, local availability, patient compliance, and cost (Hayter et al. 2011a). We wanted to determine whether CT is a suitable substitute for MARS MRI in evaluation of the painful MOM-HA. PATIENTS AND METHODS 50 MOM-HA patients (30 female) with unexplained painful prostheses underwent MARS MRI and CT imaging. 2 observers who were blind regarding the clinical data objectively reported the following outcomes: soft tissue lesions (pseudotumors), muscle atrophy, and acetabular and femoral osteolysis. Diagnostic test characteristics were calculated. RESULTS Pseudotumor was diagnosed in 25 of 50 hips by MARS MRI and in 11 of 50 by CT. Pseudotumors were classified as type 1 (n=2), type 2A (n=17), type 2B (n=4), and type 3 (n=2) by MARS MRI. CT did not permit pseudotumor classification. The sensitivity of CT for diagnosis of pseudotumor was 44% (95% CI: 25-65). CT had "slight" agreement with MARS MRI for quantification of muscle atrophy (κ=0.23, CI: 0.16-0.29; p<0.01). Osteolysis was identified in 15 of 50 patients by CT. 4 of these lesions were identified by MARS MRI. INTERPRETATION CT was found to be superior to MRI for detection of osteolysis adjacent to MOM-HA, and should be incorporated into diagnostic algorithms. CT was unable to classify and failed to detect many pseudotumors, and it was unreliable for assessment of muscle atrophy. Where MARS MRI is contraindicated or unavailable, CT would be an unsuitable substitute and other modalities such as ultrasound should be considered.
Collapse
Affiliation(s)
| | | | - Shiraz Sabah
- Institute of Musculoskeletal Science, UCL, London
| | | | - John Skinner
- Royal National Orthopaedic Hospital, Brockley Hill, Stanmore, UK
| | - Alister Hart
- Institute of Musculoskeletal Science, UCL, London
| |
Collapse
|
43
|
Nishii T, Sakai T, Takao M, Yoshikawa H, Sugano N. Is ultrasound screening reliable for adverse local tissue reaction after hip arthroplasty? J Arthroplasty 2014; 29:2239-44. [PMID: 24908625 DOI: 10.1016/j.arth.2014.04.030] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/16/2013] [Revised: 03/27/2014] [Accepted: 04/22/2014] [Indexed: 02/01/2023] Open
Abstract
There is increasing awareness of prevalence of adverse local tissue reaction (ALTR) surrounding metal-on-metal (MoM) and highly cross-linked polyethylene (HXLPE) bearings, and sensitive and simple screening modalities for ALTR are required. We examined reliability of ultrasound screening for ALTR in 131 hips of 105 patients who received both ultrasound and MRI examinations after hip arthroplasty with MoM or HXLPE bearings. Using the MRI results as reference, sensitivity, specificity and accuracy of ultrasound were 74%, 92% and 84% around MoM bearings, and 90%, 83%, and 85% around HXLPE bearings. Ultrasound detected ALTR in 11 hips that were not shown with MRI. Ultrasound examination is assumed to be a reliable screening tool for detecting clinically important ALTR lesions developing in the anterior region around MoM or HXLPE bearings.
Collapse
Affiliation(s)
- Takashi Nishii
- Department of Orthopaedic Medical Engineering, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka 565-0871, Japan
| | - Takashi Sakai
- Department of Orthopaedic Surgery, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka 565-0871, Japan
| | - Masaki Takao
- Department of Orthopaedic Surgery, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka 565-0871, Japan
| | - Hideki Yoshikawa
- Department of Orthopaedic Surgery, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka 565-0871, Japan
| | - Nobuhiko Sugano
- Department of Orthopaedic Medical Engineering, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka 565-0871, Japan
| |
Collapse
|
44
|
Perino G, Ricciardi BF, Jerabek SA, Martignoni G, Wilner G, Maass D, Goldring SR, Purdue PE. Implant based differences in adverse local tissue reaction in failed total hip arthroplasties: a morphological and immunohistochemical study. BMC Clin Pathol 2014; 14:39. [PMID: 25242891 PMCID: PMC4169255 DOI: 10.1186/1472-6890-14-39] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2014] [Accepted: 09/01/2014] [Indexed: 02/08/2023] Open
Abstract
BACKGROUND Adverse local tissue reaction (ALTR) is characterized by periprosthetic soft tissue inflammation composed of a mixed inflammatory cell infiltrate, extensive soft tissue necrosis, and vascular changes. Multiple hip implant classes have been reported to result in ALTR, and clinical differences may represent variation in the soft tissue response at the cellular and tissue levels. The purpose of this study was to describe similarities and differences in periprosthetic tissue structure, organization, and cellular composition by conventional histology and immunohistochemistry in ALTR resulting from two common total hip arthroplasty (THA) implant classes. METHODS Consecutive patients presenting with ALTR from two major hip implant classes (N = 54 patients with Dual-Modular Neck implant; N = 14 patients with Metal-on-Metal implant) were identified from our prospective Osteolysis Tissue Database and Repository. Clinical characteristics including age, sex, BMI, length of implantation, and serum metal ion levels were recorded. Retrieved synovial tissue morphology was graded using light microscopy and cellular composition was assessed using immunohistochemistry. RESULTS Length of implantation was shorter in the DMN group versus MoM THA group (21.3 [8.4] months versus 43.6 [13.8] months respectively; p < 0.005) suggesting differences in implant performance. Morphologic examination revealed a common spectrum of neo-synovial proliferation and necrosis in both groups. Macrophages were more commonly present in diffuse sheets (Grade 3) in the MoM relative to DMN group (p = 0.016). Perivascular lymphocytes with germinal centers (Grade 4) were more common in the DMN group, which trended towards significance (p = 0.066). Qualitative differences in corrosion product morphology were seen between the two groups. Immunohistochemistry showed features of a CD4 and GATA-3 rich lymphocyte reaction in both implants, with increased ratios of perivascular T-cell relative to B-cell markers in the DMN relative to the MoM group (p = 0.032). CONCLUSION Our results demonstrate that both implant classes display common features of neo-synovial proliferation and necrosis with a CD4 and GATA-3 rich inflammatory infiltrate. Qualitative differences in corrosion product appearance, macrophage morphology, and lymphocyte distributions were seen between the two implant types. Our data suggests that ALTR represents a histological spectrum with implant-based features.
Collapse
Affiliation(s)
- Giorgio Perino
- Department of Pathology, Hospital for Special Surgery, 535 East 70th Street, New York NY 10021, USA
| | - Benjamin F Ricciardi
- Department of Orthopedic Surgery, Hospital for Special Surgery, New York, NY, USA
| | - Seth A Jerabek
- Department of Orthopedic Surgery, Hospital for Special Surgery, New York, NY, USA
| | - Guido Martignoni
- Department of Pathology and Diagnostics, University of Verona, Verona and Pederzoli Hospital, Peschiera, Italy
| | - Gabrielle Wilner
- Division of Research, Hospital for Special Surgery, New York, NY, USA
| | - Dan Maass
- Division of Research, Hospital for Special Surgery, New York, NY, USA
| | - Steven R Goldring
- Division of Research, Hospital for Special Surgery, New York, NY, USA
| | - P Edward Purdue
- Division of Research, Hospital for Special Surgery, New York, NY, USA
| |
Collapse
|
45
|
Lainiala O, Elo P, Reito A, Pajamäki J, Puolakka T, Eskelinen A. Comparison of extracapsular pseudotumors seen in magnetic resonance imaging and in revision surgery of 167 failed metal-on-metal hip replacements. Acta Orthop 2014; 85:474-9. [PMID: 24954485 PMCID: PMC4164864 DOI: 10.3109/17453674.2014.934189] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
BACKGROUND AND PURPOSE Magnetic resonance imaging (MRI) is important for detecting extracapsular pseudotumors, but there is little information on the accuracy of MRI and appropriate intervals for repeated imaging. We evaluated the sensitivity and specificity of MRI for detecting pseudotumors in 155 patients (167 hips) with metal-on-metal (MoM) hip arthroplasties that failed due to adverse reactions to metal debris (ARMD). METHODS Preoperative MRIs were performed with two 1.5 T MRI scanners and graded by a senior musculoskeletal radiologist using a previously described MRI pseudotumor grading system. Revision findings were retrieved from surgical notes, and pseudotumors were retrospectively graded as fluid-filled, mixed-type, or solid. RESULTS The sensitivity of MRI was 71% and the specificity was 87% for detecting extracapsular pseudotumors. The sensitivity was 88% (95% CI: 70-96) when MRI was performed less than 3 months before the revision surgery. Interestingly, when the time that elapsed between MRI and revision was more than 1 year, the sensitivity calculated was only 29% (95% CI: 14-56). Comparison between MRI and revision classifications gave moderate agreement (Cohen's kappa = 0.4). INTERPRETATION A recent MRI predicts the presence of a pseudotumor well, but there is more discrepancy when the MRI examination is over a year old, most likely due to the formation of new pseudotumors. 1 year could be a justifiable limit for considering a new MRI if development of ARMD is suspected. MRI images over a year old should not be used in decision making or in planning of revision surgery for MoM hips.
Collapse
Affiliation(s)
- Olli Lainiala
- Coxa Hospital for Joint Replacement, Tampere, Finland
| | - Petra Elo
- Coxa Hospital for Joint Replacement, Tampere, Finland
| | - Aleksi Reito
- Coxa Hospital for Joint Replacement, Tampere, Finland
| | | | - Timo Puolakka
- Coxa Hospital for Joint Replacement, Tampere, Finland
| | | |
Collapse
|
46
|
Lombardi AV. Case studies in management of THA failure secondary to taper corrosion, modular junctions and metal-on-metal bearings. J Arthroplasty 2014; 29:663-7. [PMID: 24655612 DOI: 10.1016/j.arth.2014.02.003] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/06/2014] [Accepted: 02/03/2014] [Indexed: 02/01/2023] Open
Abstract
The diagnosis and treatment of patients with painful total hip arthroplasties secondary to taper corrosion and wear of modular junctions and metal-on-metal bearings represents a major challenge for the orthopaedic clinician. Guidelines are evolving as we analyze the growing body of evidence regarding metal-related failures of orthopaedic implants and adverse reactions to metal debris. In this article 6 case examples are presented to enhance understanding and application of current evidence into practice. Clinical expertise is integrated with the best available evidence from research and national joint registries data into the decision making process relevant for patient care in everyday practice. Issues addressed include understanding taper corrosion and metal failure mechanisms, clinical presentation of adverse soft tissue reactions, utility of specialized tests such as metal ion analysis and cross-sectional imaging studies, the utility of modular components for primary THA, dealing with recalled component, and current recommendations.
Collapse
Affiliation(s)
- Adolph V Lombardi
- Joint Implant Surgeons, Inc., New Albany, Ohio; Mount Carmel Health System, New Albany, Ohio; Department of Orthopaedics, The Ohio State University Wexner Medical Center, Columbus, Ohio
| |
Collapse
|
47
|
Abstract
BACKGROUND Adverse reaction to metal debris is a relatively recently described and often a silent complication of metal-on-metal (MOM) total hip replacements (THR). The Norfolk & Norwich University Hospital has been performing metal artefact reduction (MARS) MRI for 8 years in a variety of different types of MOM THR. QUESTIONS/PURPOSES The aims of this review are to describe the experience of using MARS MRI in Norwich and to compare our experience with that published by other groups. METHODS A MEDLINE keyword search was performed for studies including MRI in MOM THR. Relevant publications were reviewed and compared with published data from the Norfolk & Norwich University Hospital. The similarities and differences between these data were compared and possible explanations for these discussed. RESULTS MARS MRI appears to be the most useful tool for diagnosing, staging and monitoring adverse reactions to metal debris (ARMD). There appears to be no clinically useful association between clinical and serological markers of disease and the severity of MR findings. Although severe early ARMD is associated with significant morbidity, mild disease is often stable for years. If patients with normal initial MR examinations develop ARMD, this usually occurs 7 years. A 1-year interval between MRI examinations is reasonable in asymptomatic patients. CONCLUSIONS There is a general international consensus that ARMD is prevalent in symptomatic and asymptomatic patients with MOM THR and that while appearances vary with the type of prosthesis, there are characteristic features that make MARS MRI essential for diagnosis, staging and surveillance of the disease.
Collapse
|
48
|
Abstract
Total hip arthroplasty is an effective treatment option for advanced hip arthritis in elderly patients. Studies in young patients have traditionally shown less durable results. With current implants, surgical technique, and cementless fixation methods, the durability of total hip arthroplasty may now be related to the wear performance of the bearing surfaces. To improve implant longevity, there are several bearing surface choices currently available for this demanding group of patients. Alternatives must be evaluated in terms of the risks and benefits associated with each articulation, and all new technologies must be carefully monitored over the long term.
Collapse
|
49
|
Reito A, Puolakka T, Elo P, Pajamäki J, Eskelinen A. High prevalence of adverse reactions to metal debris in small-headed ASR™ hips. Clin Orthop Relat Res 2013; 471:2954-61. [PMID: 23637059 PMCID: PMC3734395 DOI: 10.1007/s11999-013-3023-6] [Citation(s) in RCA: 55] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/07/2012] [Accepted: 04/22/2013] [Indexed: 01/31/2023]
Abstract
BACKGROUND There has been increasing concern of metal-on-metal (MOM) hip replacements regarding adverse reactions to metal debris. Information regarding prevalence and risk factors for these adverse reactions is scarce. QUESTIONS/PURPOSES The primary purposes of our study were to determine (1) the prevalence of adverse reactions to metal debris among patients who received small-headed (< 50 mm) Articular Surface Replacement (ASR™) prostheses in hip resurfacing procedures or the ASR™ XL prostheses during THAs at our institution, and (2) the risk factors for adverse reactions to metal debris and if they are different in hip resurfacing replacements compared with THAs? METHODS Small-headed ASR™ prostheses were used in 482 operations (424 patients) at our institution. After the recall of ASR™ prostheses, we established a systematic screening program to find patients with adverse reactions to metal debris. At a mean of 4.9 years (range, 0.2-8.1 years) postoperatively, 379 patients (435 hips) attended a screening program, which consisted of clinical evaluation, whole blood cobalt and chromium measurements, and cross-sectional imaging. RESULTS At followup, 162 hips (34%) have been revised. The majority (85%) were revised owing to causes related to adverse reactions to metal debris. The 7-year survivorship was 51% for the ASR™ hip replacement cohort and 38% for the ASR™ XL THA cohort, respectively. Reduced cup coverage was an independent risk factor for adverse reactions to metal debris in both cohorts. High preoperative ROM, use of the Corail(®) stem, and female gender were associated with an increased risk of adverse reactions to metal debris only in patients undergoing THA. CONCLUSIONS Adverse reactions to metal debris are common with small-headed ASR™ prostheses. Risk factors for these adverse reactions differ between hip resurfacing procedures and THAs. Our results suggest a more complicated failure mechanism in THAs than in hip resurfacing procedures.
Collapse
Affiliation(s)
- Aleksi Reito
- Coxa Hospital for Joint Replacement, P.O. Box 652, 33101 Tampere, Finland
| | - Timo Puolakka
- Coxa Hospital for Joint Replacement, P.O. Box 652, 33101 Tampere, Finland
| | - Petra Elo
- Coxa Hospital for Joint Replacement, P.O. Box 652, 33101 Tampere, Finland
| | - Jorma Pajamäki
- Coxa Hospital for Joint Replacement, P.O. Box 652, 33101 Tampere, Finland
| | - Antti Eskelinen
- Coxa Hospital for Joint Replacement, P.O. Box 652, 33101 Tampere, Finland
| |
Collapse
|