1
|
Steinhardt M, Marka AW, Ziegelmayer S, Makowski M, Braren R, Graf M, Gawlitza J. Comparison of Virtual Non-Contrast and True Non-Contrast CT Images Obtained by Dual-Layer Spectral CT in COPD Patients. Bioengineering (Basel) 2024; 11:301. [PMID: 38671723 PMCID: PMC11047621 DOI: 10.3390/bioengineering11040301] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2024] [Revised: 03/10/2024] [Accepted: 03/19/2024] [Indexed: 04/28/2024] Open
Abstract
Chronic obstructive pulmonary disease (COPD) is one of the leading causes of death. Recent studies have underlined the importance of non-contrast-enhanced chest CT scans not only for emphysema progression quantification, but for correlation with clinical outcomes as well. As about 40 percent of the 300 million CT scans per year are contrast-enhanced, no proper emphysema quantification is available in a one-stop-shop approach for patients with known or newly diagnosed COPD. Since the introduction of spectral imaging (e.g., dual-energy CT scanners), it has been possible to create virtual non-contrast-enhanced images (VNC) from contrast-enhanced images, making it theoretically possible to offer proper COPD imaging despite contrast enhancing. This study is aimed towards investigating whether these VNC images are comparable to true non-contrast-enhanced images (TNC), thereby reducing the radiation exposure of patients and usage of resources in hospitals. In total, 100 COPD patients with two scans, one with (VNC) and one without contrast media (TNC), within 8 weeks or less obtained by a spectral CT using dual-layer technology, were included in this retrospective study. TNC and VNC were compared according to their voxel-density histograms. While the comparison showed significant differences in the low attenuated volumes (LAVs) of TNC and VNC regarding the emphysema threshold of -950 Houndsfield Units (HU), the 15th and 10th percentiles of the LAVs used as a proxy for pre-emphysema were comparable. Upon further investigation, the threshold-based LAVs (-950 HU) of TNC and VNC were comparable in patients with a water equivalent diameter (DW) below 270 mm. The study concludes that VNC imaging may be a viable option for assessing emphysema progression in COPD patients, particularly those with a normal body mass index (BMI). Further, pre-emphysema was generally comparable between TNC and VNC. This approach could potentially reduce radiation exposure and hospital resources by making additional TNC scans obsolete.
Collapse
Affiliation(s)
- Manuel Steinhardt
- Department of Diagnostic and Interventional Radiology, School of Medicine & Klinikum rechts der Isar, Technical University of Munich, 81675 Munich, Germany; (A.W.M.); (S.Z.); (M.M.); (R.B.); (M.G.)
| | | | | | | | | | | | - Joshua Gawlitza
- Correspondence: (M.S.); (J.G.); Tel.: +49-176-24498226 (M.S.); +49-89-4140-8834 (J.G.)
| |
Collapse
|
2
|
Lorenzatti D, Piña P, Daich J, Scotti A, Perez-Cervera J, Miranda R, Feinberg AJ, Halliburton SS, Ivanc TB, Schenone AL, Kuno T, Latib A, Dey D, Pibarot P, Dweck MR, Garcia MJ, Slipczuk L. Diagnostic accuracy of virtual non-contrast CT for aortic valve stenosis severity evaluation. J Cardiovasc Comput Tomogr 2024; 18:50-55. [PMID: 38314547 DOI: 10.1016/j.jcct.2023.10.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/15/2023] [Accepted: 10/13/2023] [Indexed: 02/06/2024]
Abstract
BACKGROUND Computed tomography aortic valve calcium (AVC) score has accepted value for diagnosing and predicting outcomes in aortic stenosis (AS). Multi-energy CT (MECT) allows virtual non-contrast (VNC) reconstructions from contrast scans. We aim to compare the VNC-AVC score to the true non-contrast (TNC)-AVC score for assessing AS severity. METHODS We prospectively included patients undergoing a MECT for transcatheter aortic valve replacement (TAVR) planning. TNC-AVC was acquired before contrast, and VNC-AVC was derived from a retrospectively gated contrast-enhanced scan. The Agatston scoring method was used for quantification, and linear regression analysis to derive adjusted-VNC values. RESULTS Among 109 patients (55% female) included, 43% had concordant severe and 14% concordant moderate AS. TNC scan median dose-length product was 116 mGy∗cm. The median TNC-AVC was 2,107 AU (1,093-3,372), while VNC-AVC was 1,835 AU (1293-2,972) after applying the coefficient (1.46) and constant (743) terms. A strong correlation was demonstrated between methods (r = 0.93; p < 0.001). Using accepted thresholds (>1,300 AU for women and >2,000 AU for men), 65% (n = 71) of patients had severe AS by TNC-AVC and 67% (n = 73) by adjusted-VNC-AVC. After estimating thresholds for adjusted-VNC (>1,564 AU for women and >2,375 AU for men), 56% (n = 61) had severe AS, demonstrating substantial agreement with TNC-AVC (κ = 0.77). CONCLUSIONS MECT-derived VNC-AVC showed a strong correlation with TNC-AVC. After adjustment, VNC-AVC demonstrated substantial agreement with TNC-AVC, potentially eliminating the requirement for an additional scan and enabling reductions in both radiation exposure and acquisition time.
Collapse
Affiliation(s)
- Daniel Lorenzatti
- Division of Cardiology, Montefiore Medical Center/Albert Einstein College of Medicine. Bronx, NY, USA
| | - Pamela Piña
- Division of Cardiology, Montefiore Medical Center/Albert Einstein College of Medicine. Bronx, NY, USA; Division of Cardiology, CEDIMAT, Santo Domingo, Dominican Republic
| | - Jonathan Daich
- Division of Cardiology, Montefiore Medical Center/Albert Einstein College of Medicine. Bronx, NY, USA
| | - Andrea Scotti
- Division of Cardiology, Montefiore Medical Center/Albert Einstein College of Medicine. Bronx, NY, USA
| | | | - Rita Miranda
- Division of Cardiology, Montefiore Medical Center/Albert Einstein College of Medicine. Bronx, NY, USA
| | - Ari J Feinberg
- Division of Cardiology, Montefiore Medical Center/Albert Einstein College of Medicine. Bronx, NY, USA
| | | | - Thomas B Ivanc
- CT Clinical Science, Philips Healthcare, Cleveland, OH, USA
| | - Aldo L Schenone
- Division of Cardiology, Montefiore Medical Center/Albert Einstein College of Medicine. Bronx, NY, USA
| | - Toshiki Kuno
- Division of Cardiology, Montefiore Medical Center/Albert Einstein College of Medicine. Bronx, NY, USA
| | - Azeem Latib
- Division of Cardiology, Montefiore Medical Center/Albert Einstein College of Medicine. Bronx, NY, USA
| | - Damini Dey
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, CA, USA
| | - Philippe Pibarot
- Institut Universitaire de Cardiologie et de Pneumologie de Québec/Québec Heart and Lung Institute, Université Laval, Québec, Canada
| | - Marc R Dweck
- British Heart Foundation Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, United Kingdom
| | - Mario J Garcia
- Division of Cardiology, Montefiore Medical Center/Albert Einstein College of Medicine. Bronx, NY, USA
| | - Leandro Slipczuk
- Division of Cardiology, Montefiore Medical Center/Albert Einstein College of Medicine. Bronx, NY, USA.
| |
Collapse
|
3
|
Influence of BMI on virtual coronary artery calcium scoring. Int J Cardiovasc Imaging 2022; 39:863-872. [PMID: 36583813 DOI: 10.1007/s10554-022-02785-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/10/2022] [Accepted: 12/19/2022] [Indexed: 12/31/2022]
Abstract
PURPOSE Virtual non-contrast (VNC) coronary artery calcium scoring (CAC) may obviate the need for traditional non-contrast (TNC) CAC. There is no data on the influence of body mass index (BMI) on VNC reliability. We aimed to evaluate the influence of BMI on VNC CAC agreement with TNC. MATERIALS AND METHODS All patients who underwent sequential CAC and coronary CT angiography (CCTA) using spectral CT with TNC CAC > 0 between August 2020 and December 2021 were included. Agatston CAC scores were calculated manually by 2 blinded readers from VNC scans. A correction factor was calculated from the slope of the linear regression using the method of least squares and applied to the VNC scores. Bland-Altman plots and Cohen's weighted Kappa were utilized. RESULTS We included 174 patients (57.5% female). Mean BMI was 32.6 ± 7.02 kg/m2 [BMI < 30 (39.7%); BMI 30-40 (45.4%); and BMI > 40 kg/m2 (14.9%)]. Mean TNC CAC was 177.8 ± 316.86 and mean VNC CAC after applying the correction factor 149.34 ± 296.73. The TNC value strongly correlated with VNC (r = 0.94; p < 0.0001). As BMI increased there was a progressive reduction in signal-to-noise ratio, contrast-to-noise ratio and coronary enhancement (p < 0.05). The degree of agreement between VNC and TNC CAC decreased as BMI increased (agreement = 91.79 (weighted Kappa = 0.72), 91.14 (weighted Kappa = 0.58) and 88.46% (weighted Kappa = 0.48) (all P values < 0.001) for BMI < 30; 30-40 and > 40 kg/m2, respectively). CONCLUSION BMI has a significant influence on the accuracy of VNC CAC. VNC CAC shows substantial agreement in non-obese patients but performs poorly in BMI > 40 kg/m2. This is the first study to evaluate the influence of body mass index (BMI) on virtual non-contrast (VNC) coronary artery calcium scoring (CAC) as compared to traditional non-contrast (TNC). We retrospectively evaluated 174 patients with TNC CAC and two blinded reviewers manually calculated the VNC CAC. All cases were included without specific selection for quality. The ratio between the two directly proportional values was determined using the slope from the linear regression through the method of least squares. This correction factor of 2.65 was applied to the calcium scores obtained from VNC images. We found that VNC CAC shows substantial risk-class agreement with TNC in non-obese patients (agreement = 91.79 and weighted Kappa = 0.72) but performs poorly in BMI > 40 kg/m2 (agreement: 88.46% and weighted Kappa = 0.48). These findings show the potential use of VNC CAC to avoid additional radiation in non-obese patients. However, further research on potential improvement strategies for VNC CAC in obese patients is needed.
Collapse
|
4
|
Nadjiri J, Koppara T, Kafka A, Weis F, Rasper M, Gassert FG, von Schacky CE, Pfeiffer D, Laugwitz KL, Makowski MR, Ibrahim T. Coronary plaque characterization assessed by delayed enhancement dual-layer spectral CT angiography and optical coherence tomography. Int J Cardiovasc Imaging 2022; 38:2491-2500. [DOI: 10.1007/s10554-022-02638-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/29/2022] [Accepted: 04/28/2022] [Indexed: 11/29/2022]
|
5
|
Calcium scoring using virtual non-contrast images from a dual-layer spectral detector CT: comparison to true non-contrast data and evaluation of proportionality factor in a large patient collective. Eur Radiol 2021; 31:6193-6199. [PMID: 33474570 PMCID: PMC8270810 DOI: 10.1007/s00330-020-07677-w] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2020] [Revised: 11/23/2020] [Accepted: 12/29/2020] [Indexed: 01/07/2023]
Abstract
OBJECTIVE Determination of coronary artery calcium scoring (CACS) in non-contrast computed tomography (CT) images has been shown to be an important prognostic factor in coronary artery disease (CAD). The objective of this study was to evaluate the accuracy of CACS from virtual non-contrast (VNC) imaging generated from spectral data in comparison to standard (true) non-contrast (TNC) imaging in a representative patient cohort with clinically approved software. METHODS One hundred three patients referred to coronary CTA with suspicion of CAD were investigated on a dual-layer spectral detector CT (SDCT) scanner. CACS was calculated from both TNC and VNC images by software certified for medical use. Patients with a CACS of 0 were excluded from analysis. RESULTS The mean age of the study population was 61 ± 11 years with 48 male patients (67%). Inter-quartile range of clinical CACS was 22-282. Correlation of measured CACS from true- and VNC images was high (0.95); p < 0.001. The slope was 3.83, indicating an underestimation of VNC CACS compared to TNC CACS by that factor. Visual analysis of the Bland-Altman plot of CACS showed good accordance with both methods after correction of VNC CACS by the abovementioned factor. CONCLUSIONS In clinical diagnostics of CAD, the determination of CACS is feasible using VNC images generated from spectral data obtained on a dual-layer spectral detector CT. When multiplied by a correction factor, results were in good agreement with the standard technique. This could enable radiation dose reductions by obviating the need for native scans typically used for CACS. KEY POINTS • Calcium scoring is feasible from contrast-enhanced CT images using a dual-layer spectral detector CT scanner. • When multiplied by a correction factor, calcium scoring from virtual non-contrast images shows good agreement with the standard technique. • Omitting native scans for calcium scoring could enable radiation dose reduction.
Collapse
|
6
|
Topçuoğlu OM, Sarıkaya B. Fast kilovoltage-switching dual-energy CT offering lower x-ray dose than single-energy CT for the chest: a quantitative and qualitative comparison study of the two methods of acquisition. Diagn Interv Radiol 2019; 25:204-209. [PMID: 31085505 PMCID: PMC6521909 DOI: 10.5152/dir.2019.18412] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2018] [Revised: 10/07/2018] [Accepted: 11/13/2018] [Indexed: 11/22/2022]
Abstract
PURPOSE We aimed to compare the size-specific dose estimates (SSDE), computed tomography (CT) dose indices and image quality parameters of the chest CTs obtained with fast kilovoltage-switching (FKS) dual-energy (DE) CT versus those with single-energy (SE) CT. METHODS Patients who had chest SECT within the last 6 months were prospectively scanned with chest FKS-DECT. Quantitative comparison was made by calculating the mean SSDE, CTDIvol, contrast, noise, contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR) for both acquisitions. Two radiologists evaluated the chest SECT and DECT images qualitatively blinded to the technique used. The paired Student's t test was utilized for comparing the quantitative and qualitative data. Inter- and intraobserver agreement were also assessed. RESULTS A total of 42 patients were included. The mean SSDE, CTDIvol, contrast, noise, CNR, and SNR for SECT versus DECT were 12.7±2.2 mGy vs. 9.3±1.2 mGy (P = 0.001), 10.9±2.4 mGy vs. 8±1.2 mGy (P < 0.001), 211.9±44.7 vs. 216.3±59 (P = 0.350), 12.9±2.4 vs. 13.9±3.7 (P = 0.086), 13.5±5.2 vs. 13.3±8.4 (P = 0.548) and 12±3.5 vs. 11.5±3.4 (P = 0.774), respectively. Interobserver reproducibility was high for contrast, noise, CNR, and SNR (ICC = 0.89, 0.85, 0.93, and 0.82, respectively; all P < 0.05). Intraobserver reproducibility was high for contrast, noise, CNR, and SNR (ICC = 0.80, 0.77, 0.85, and 0.88, respectively; all P < 0.05). CONCLUSION The mean SSDE of the chest CTs obtained with FKS-DECT were 26.8% lower than those with SECT with significant difference for the objective assessment and there was no significant difference for the subjective assessment of the image qualities, in this series.
Collapse
Affiliation(s)
- Osman Melih Topçuoğlu
- From the Department of Radiology (O.M.T. ) Yeditepe University School of Medicine, İstanbul, Turkey
| | - Başar Sarıkaya
- From the Department of Radiology (O.M.T. ) Yeditepe University School of Medicine, İstanbul, Turkey
| |
Collapse
|
7
|
Nadjiri J, Kaissis G, Meurer F, Weis F, Laugwitz KL, Straeter AS, Muenzel D, Noël PB, Rummeny EJ, Rasper M. Accuracy of Calcium Scoring calculated from contrast-enhanced Coronary Computed Tomography Angiography using a dual-layer spectral CT: A comparison of Calcium Scoring from real and virtual non-contrast data. PLoS One 2018; 13:e0208588. [PMID: 30521612 PMCID: PMC6283621 DOI: 10.1371/journal.pone.0208588] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2018] [Accepted: 11/20/2018] [Indexed: 01/07/2023] Open
Abstract
Purpose Modern non-invasive evaluation of Coronary Artery Disease (CAD) requires non-contrast low dose Computed Tomography (CT) imaging for determination of Calcium Scoring (CACS) and contrast-enhanced imaging for evaluation of vascular stenosis. Several methods for calculation of CACS from contrast-enhanced images have been proposed before. The main principle for that is generation of virtual non-contrast images by iodine subtraction from a contrast-enhanced spectral CT dataset. However, those techniques have some limitations: Dual-Source CT imaging can lead to increased radiation exposure, and switching of the tube voltage (rapid kVp switching) can be associated with slower rotation speed of the gantry and is thus prone to motion artefacts that are especially critical in cardiac imaging. Both techniques cannot simultaneously acquire spectral data. A novel technique to overcome these difficulties is spectral imaging with a dual-layer detector. After absorption of the lower energetic photons in the first layer, the second layer detects a hardened spectrum of the emitted radiation resulting in registration of two different energy spectra at the same time. The objective of the present investigation was to evaluate the accuracy of virtual non-contrast CACS computed from spectral data in comparison to standard non-contrast imaging. Methods We consecutively investigated 20 patients referred to Coronary Computed Tomography Angiography (CCTA) with suspicion of CAD using a Dual-Layer spectral CT system (IQon; Philips Healthcare, The Netherlands). CACS was calculated from both, real- and virtual non-contrast images by certified software for medical use. Correlation analyses for real- and virtual non-contrast images and agreement evaluation with Bland-Altman-Plots were performed. Results Mean patient age was 57.7 ± 14 years (n = 20). 13 patients (65%) were male. Inter-quartile-range of clinical CACS was 0–448, the mean was 334. Correlation of CACS from real- and virtual non-contrast images was very high (0.94); p < 0.0001. The slope was 2.3 indicating that values from virtual non-contrast images are approximately half of the results obtained from real non-contrast data. Visual analysis of Bland-Altman-Plot shows good accordance of both methods when results from virtual non-contrast data are multiplied by the slope of the logistic regression model (2.3). The acquired power of this results is 0.99. Conclusion Determination of Calcium Score from contrast enhanced CCTA using spectral imaging with a dual-layer detector is feasible and shows good agreement with the conventional technique when a proportionality factor is applied. The observed difference between both methods is due to an underestimation of plaque volume, and—to an even greater extend -an underestimation of plaque density with the virtual non-contrast approach. Our data suggest that radiation exposure can be reduced through omitting additional native scans for patients referred to CCTA when using a dual-layer spectral system without the usual limitations of dual energy analysis.
Collapse
Affiliation(s)
- Jonathan Nadjiri
- Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
- * E-mail:
| | - Georgios Kaissis
- Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Felix Meurer
- Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Florian Weis
- Department of Cardiology, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Karl-Ludwig Laugwitz
- Department of Cardiology, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Alexandra S. Straeter
- Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Daniela Muenzel
- Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
- Chair of Biomedical Physics & Munich School of BioEngineering, Technical University of Munich, Munich, Germany
| | - Peter B. Noël
- Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
- Chair of Biomedical Physics & Munich School of BioEngineering, Technical University of Munich, Munich, Germany
| | - Ernst J. Rummeny
- Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Michael Rasper
- Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| |
Collapse
|
8
|
Gong B, Wu Y, O'Keeffe ME, Berger FH, McLaughlin PD, Nicolaou S, Khosa F. Top 50 Highly Cited Articles on Dual Energy Computed Tomography (DECT) in Abdominal Radiology: A Bibliometric Analysis. Pol J Radiol 2018; 82:748-759. [PMID: 29657641 PMCID: PMC5894048 DOI: 10.12659/pjr.904075] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2017] [Accepted: 03/14/2017] [Indexed: 11/11/2022] Open
Abstract
This study aims to identify the 50 most highly cited articles on dual energy computed tomography (DECT) in abdominal radiology Thomson Reuters Web of Science All Databases was queried without year or language restriction. Only original research articles with a primary focus on abdominal radiology using DECT were selected. Review articles, meta-analyses, and studies without human subjects were excluded. Fifty articles with the highest average yearly citation were identified. These articles were published between 2007 and 2017 in 12 journals, with the most in Radiology (12 articles). Articles had a median of 7 authors, with all first authors but one primarily affiliated to radiology departments. The United States of America produced the most articles (16), followed by Germany (13 articles), and China (7 articles). Most studies used Dual Source DECT technology (35 articles), followed by Rapid Kilovoltage Switching (14 articles), and Sequential Scanning (1 article). The top three scanned organs were the liver (24%), kidney (16%), and urinary tract (15%). The most commonly studied pathology was urinary calculi (28%), renal lesion/tumor (23%), and hepatic lesion/tumor (20%). Our study identifies intellectual milestones in the applications of DECT in abdominal radiology. The diversity of the articles reflects on the characteristics and quality of the most influential publications related to DECT.
Collapse
Affiliation(s)
- Bo Gong
- Department of Emergency and Trauma Radiology, Vancouver General Hospital, Vancouver, BC, Canada
| | - Yuhao Wu
- Department of Emergency and Trauma Radiology, Vancouver General Hospital, Vancouver, BC, Canada
| | - Michael E O'Keeffe
- Department of Emergency and Trauma Radiology, Vancouver General Hospital, Vancouver, BC, Canada
| | - Ferco H Berger
- Department of Medical Imaging, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, ON, Canada
| | - Patrick D McLaughlin
- Department of Emergency and Trauma Radiology, Vancouver General Hospital, Vancouver, BC, Canada
| | - Savvas Nicolaou
- Department of Emergency and Trauma Radiology, Vancouver General Hospital, Vancouver, BC, Canada
| | - Faisal Khosa
- Department of Emergency and Trauma Radiology, Vancouver General Hospital, Vancouver, BC, Canada
| |
Collapse
|
9
|
Abstract
Reignited by innovations in scanner engineering and software design, dual-energy computed tomography (CT) has come back into the clinical radiology arena in the last decade. Possibilities for noninvasive in vivo characterization of genitourinary disease, especially for renal stones and renal masses, have become the pinnacle offerings of dual-energy CT for body imaging in clinical practice. This article renders a state-of-the-art review on clinical applications of dual-energy CT in genitourinary imaging.
Collapse
Affiliation(s)
- Achille Mileto
- Department of Radiology, University of Washington School of Medicine, Box 357115, 1959 Northeast Pacific Street, Seattle, WA 98195, USA
| | - Daniele Marin
- Department of Radiology, Duke University Medical Center, Box 3808 Erwin Road, Durham, NC 27710, USA.
| |
Collapse
|
10
|
|
11
|
Schick D, Pratap J. Radiation dose efficiency of dual-energy CT benchmarked against single-source, kilovoltage-optimized scans. Br J Radiol 2015; 89:20150486. [PMID: 26559438 DOI: 10.1259/bjr.20150486] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVE This study evaluated the radiation dose and image quality implications of dual-energy CT (DECT) use, compared with kilovoltage-optimized single-source/single-energy CT (SECT) on a dual-source Siemens Somatom(®) Definition Flash CT scanner (Siemens Healthcare, Forcheim, Germany). METHODS With equalized radiation dose (volumetric CT dose index), image noise (standard deviation of CT number) and signal-difference-to-noise ratio (SDNR) were measured and compared across three techniques: 100, 120 and 100/140 kVp (dual energy). Noise in a 30-cm-diameter water phantom and SDNR within unenhanced soft-tissue regions of a small adult (50 kg/165 cm) anthropomorphic phantom were utilized for the assessment. RESULTS Water phantom image noise decreased with DECT compared with the lower noise SECT setting of 120 kVp (p = 0.046). A decrease in SDNR within the anthropomorphic phantom was demonstrated at 120 kVp compared with the SECT kilovoltage-optimized setting of 100 kVp (p = 0.001). A further decrease in SDNR was observed for the DECT technique when compared with 120 kVp (p = 0.01). CONCLUSION On the Siemens Somatom Definition Flash system (Siemens Healthcare), and for equalized radiation dose conditions, image quality expressed as SDNR of unenhanced soft tissue may be compromised for DECT when compared with kilovoltage-optimized SECT, particularly for smaller patients. ADVANCES IN KNOWLEDGE DECT on a dual-source CT scanner may require a radiation dose increase to maintain unenhanced soft-tissue contrast detectability, particularly for smaller patients.
Collapse
Affiliation(s)
- Daniel Schick
- 1 Biomedical Technology Services, Health Support Queensland, Queensland, Australia
| | - Jit Pratap
- 2 Division of Diagnostic Radiology, Princess Alexandra Hospital, Brisbane, Australia
| |
Collapse
|
12
|
Faby S, Kuchenbecker S, Sawall S, Simons D, Schlemmer HP, Lell M, Kachelrieß M. Performance of today's dual energy CT and future multi energy CT in virtual non-contrast imaging and in iodine quantification: A simulation study. Med Phys 2015; 42:4349-66. [DOI: 10.1118/1.4922654] [Citation(s) in RCA: 148] [Impact Index Per Article: 16.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023] Open
|
13
|
Dual energy MDCT assessment of renal lesions: an overview. Eur Radiol 2013; 24:353-62. [DOI: 10.1007/s00330-013-3030-8] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2013] [Revised: 08/26/2013] [Accepted: 09/11/2013] [Indexed: 02/07/2023]
|