1
|
Han JW, Son J, Oh C. Features of colonic diverticulitis in children and adolescents: A multicenter study. Asian J Surg 2024; 47:2195-2199. [PMID: 38388263 DOI: 10.1016/j.asjsur.2024.02.049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2023] [Revised: 01/21/2024] [Accepted: 02/02/2024] [Indexed: 02/24/2024] Open
Abstract
BACKGROUND Colonic diverticulitis (CD), typically seen in the elderly of Western countries, is increasingly prevalent worldwide, yet data on CD in children and adolescents are scarce. This study explores the characteristics of CD in this younger demographic. METHODS In a multicenter, retrospective review, 104 patients under 20 years diagnosed with CD at four Korean tertiary hospitals from June 2003 to December 2020 were analyzed. Abdominal CT scans were used for diagnosis, with the modified Hinchey classification assessing the severity of CD. RESULTS CD was found in the cecum or ascending colon in 103 (99%) of cases. The mean patient age was 17.24 ± 2.4 years, with males constituting 59.6% of cases. Solitary lesions were noted in 93 (89.4%) of patients. Severity was classified as modified Hinchey stage 0 in 58.7%, stage Ia in 29.8%, and stage Ib in 11.5%, with no cases of stage II or higher. Misdiagnosis as acute appendicitis occurred in six instances. IV antibiotics were administered to 68.3%, and oral antibiotics were sufficient for 24%. Surgical treatment was necessary for two patients. A 7.8% recurrence rate was noted among first-time CD patients, yet all cases were amenable to conservative management. CONCLUSION While uncommon, CD in children and adolescents is a growing concern, with most cases presenting as solitary lesions in the cecum or ascending colon. The severity is typically less than that in adults, and conservative treatment is generally effective. These findings underscore the need for specific management guidelines for pediatric CD, advocating for non-surgical initial approaches.
Collapse
Affiliation(s)
- Ji-Won Han
- Department of Surgery, Ewha Womans University Seoul Hospital, Seoul, South Korea
| | - Joonhyuk Son
- Department of Pediatric Surgery, Hanyang University College of Medicine, Seoul, South Korea
| | - Chaeyoun Oh
- Department of Surgery, Korea University College of Medicine, Ansan, South Korea.
| |
Collapse
|
2
|
Mussmann B, Hardy M, Jung H, Ding M, Osther PJ, Fransen ML, Greisen PW, Graumann O. Renal stone detection using a low kilo-voltage paediatric CT protocol - a porcine phantom study. J Med Radiat Sci 2021; 68:342-348. [PMID: 34159743 PMCID: PMC8656188 DOI: 10.1002/jmrs.523] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2020] [Accepted: 06/03/2021] [Indexed: 11/18/2022] Open
Abstract
INTRODUCTION Reducing tube voltage is an effective dose saving method in computed tomography (CT) assuming tube current is not concurrently increased. Recent innovations in scanner technology now enable CT tube voltage reduction to 70 kV thereby increasing opportunities for dose reduction in paediatric patients, but it is unclear if the increased image noise associated with 70 kV impacts on ability to visualise renal stones accurately. The purpose was to assess detectability of nephrolithiasis using a bespoke paediatric phantom and low kV, non-contrast CT and to assess inter-observer agreement. METHODS Forty-two renal stones of different size and chemical composition were inserted into porcine kidneys and positioned in a bespoke, water-filled phantom mimicking a 9-year-old child weighing approximately 33kg. The phantom was scanned using 120 and 70 kV CT protocols, and the detectability of the stones was assessed by three radiologists. Absolute agreement and Fleiss' kappa regarding detectability were assessed. RESULTS The mean diameter of renal stones as measured physically was 4.24 mm ranging from 1 to 11 mm. Four stones were missed by at least one observer. One observer had a sensitivity of 93 and 95% at 70 and 120 kV, respectively, while the sensitivity for observers 2 and 3 was 98% at both kV levels. Specificity was 100% across readers and kV levels. Absolute agreement between the readers at 70 kV was 92% (kappa = 0.86) and 98% (kappa = 0.96) at 120 kV indicating a strong agreement at both kV levels. CONCLUSIONS The results suggest that lowering the kV does not affect the detection rate of renal stones and may be a useful dose reduction strategy for assessment of nephrolithiasis in children.
Collapse
Affiliation(s)
- Bo Mussmann
- Department of RadiologyOdense University HospitalOdenseDenmark
- Research and Innovation Unit of RadiologyUniversity of Southern DenmarkOdenseDenmark
- Faculty of Health SciencesOslo Metropolitan UniversityOsloNorway
| | - Maryann Hardy
- Research and Innovation Unit of RadiologyUniversity of Southern DenmarkOdenseDenmark
- Faculty of Health StudiesUniversity of BradfordBradfordUK
| | - Helene Jung
- Urological Research CenterDepartment of UrologyLillebaelt HospitalVejleDenmark
- Department of Regional Health ResearchUniversity of Southern DenmarkOdenseDenmark
| | - Ming Ding
- Department of Orthopaedic surgery and traumatologyOdense University HospitalOdenseDenmark
- Department of Clinical ResearchUniversity of Southern DenmarkOdenseDenmark
| | - Palle J. Osther
- Urological Research CenterDepartment of UrologyLillebaelt HospitalVejleDenmark
- Department of Regional Health ResearchUniversity of Southern DenmarkOdenseDenmark
| | | | | | - Ole Graumann
- Department of RadiologyOdense University HospitalOdenseDenmark
- Research and Innovation Unit of RadiologyUniversity of Southern DenmarkOdenseDenmark
| |
Collapse
|
3
|
Shohji T. [9. Basics of Radiation Exposure in X-ray CT]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2021; 77:1223-1230. [PMID: 34670931 DOI: 10.6009/jjrt.2021_jsrt_77.10.1223] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
4
|
Zhang T, Geng X, Li D, Xu Y, Zhao Y. Comparison of the image quality and radiation dose of different scanning modes in head-neck CT angiography. Dentomaxillofac Radiol 2021; 50:20200428. [PMID: 33353399 DOI: 10.1259/dmfr.20200428] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVES To analyze and compare the radiation dose and image quality of different CT scanning modes on head-neck CT angiography. METHODS A total of 180 patients were divided into Group A and Group B. The groups were further subdivided according to different scanning modes: subgroups A1, A2, A3, B1, B2, and B3. Subgroups A1 and B1 used conventional CT protocol, subgroups A2 and B2 used the kV-Assist scan mode, and subgroups A3 and B3 used the dual-energy gemstone spectral imaging protocol. The CT dose index and dose-length product were recorded. The objective image quality and subjective image evaluation was conducted by two independent radiologists. RESULTS The signal-to-noise ratios, contrast-to-noise ratios, and subjective scores of subgroups A3 and B3 were higher than the other subgroups. In subgroups B1 and B2, the subjective scores of 9 patients and 12 patients were lower than 3, respectively. The subjective scores of subgroups B1 and B2 were lower than the other subgroups. There was no statistically significant difference in signal-to-noise ratios, contrast-to-noise ratios, and subjective scores between subgroups A1 and A2. The effective dose of subgroup A2 was 41.7 and 36.4% lower than that in subgroups A1 and A3, respectively (p < 0.05). In Group B, there were no statistically significant differences in CT dose indexvol, dose-length product, and ED among the subgroups (p > 0.05). CONCLUSION In the head-neck CT angiography, the kV-Assist scan mode is recommended for patients with body mass index between 18.5 and 34.9 kg m-2; gemstone spectral imaging scanning mode is recommended for patients with body mass index ≥34.9 kg m-2.
Collapse
Affiliation(s)
- Tianle Zhang
- Department of Radiology, The Affiliated Hospital of Hebei University, Baoding, China
| | - Xue Geng
- Department of Radiology, Baoding No.2 hospital, Baoding, China
| | - Dongxue Li
- Department of Radiology, The Affiliated Hospital of Hebei University, Baoding, China
| | - Yize Xu
- Department of Radiology, The Affiliated Hospital of Hebei University, Baoding, China
| | - Yongxia Zhao
- Department of Radiology, The Affiliated Hospital of Hebei University, Baoding, China
| |
Collapse
|
5
|
Low Radiation Dose Implications in Obese Abdominal Computed Tomography Imaging. APPLIED SCIENCES-BASEL 2021. [DOI: 10.3390/app11062456] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
The aim of this study was to evaluate the implications of low radiation dose in abdominal computed tomography (CT) when combined with noise reduction filters and to see if this approach can overcome the challenges that arise while scanning obese patients. Anthropomorphic phantoms layered with and without 3-cm-thick circumferential animal fat packs to simulate different sized patients were scanned using a 128-slice multidetector CT (MDCT) scanner. Abdominal protocols (n = 12) were applied using various tube currents (150, 200, 250, and 300 mA) and tube voltages (100, 120, and 140 kVp). MOSFET dosimeters measured the internal organ dose. All images were reconstructed with filtered back projection (FBP) and different iterative reconstruction (IR) strengths (SAFIRE 3, SAFIRE 4, and SAFIRE 5) techniques and objective noise was measured within three regions of interests (ROIs) at the level of L4–L5. Organ doses varied from 0.34–56.2 mGy; the colon received the highest doses for both phantom sizes. Compared to the normal-weighted phantom, the obese phantom was associated with an approximately 20% decrease in effective dose. The 100 kVp procedure resulted in a 40% lower effective dose (p < 0.05) compared to at 120 kVp and the associated noise increase was improved by increasing the IR (5) use, which resulted in a 60% noise reduction compared to when using FBP (p < 0.05). When combined with iterative reconstruction, the low-kVp approach is feasible for obese patients in order to optimize radiation dose and maintain objective image quality.
Collapse
|
6
|
Evaluation of Organ Dose and Image Quality Metrics of Pediatric CT Chest-Abdomen-Pelvis (CAP) Examination: An Anthropomorphic Phantom Study. APPLIED SCIENCES-BASEL 2021. [DOI: 10.3390/app11052047] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
The aim of this study is to investigate the impact of CT acquisition parameter setting on organ dose and its influence on image quality metrics in pediatric phantom during CT examination. The study was performed on 64-slice multidetector CT scanner (MDCT) Siemens Definition AS (Siemens Sector Healthcare, Forchheim, Germany) using various CT CAP protocols (P1–P9). Tube potential for P1, P2, and P3 protocols were fixed at 100 kVp while P4, P5, and P6 were fixed at 80 kVp with used of various reference noise values. P7, P8, and P9 were the modification of P1 with changes on slice collimation, pitch factor, and tube current modulation (TCM), respectively. TLD-100 chips were inserted into the phantom slab number 7, 9, 10, 12, 13, and 14 to represent thyroid, lung, liver, stomach, gonads, and skin, respectively. The image quality metrics, signal to noise ratio (SNR) and contrast to noise ratio (CNR) values were obtained from the CT console. As a result, this study indicates a potential reduction in the absorbed dose up to 20% to 50% along with reducing tube voltage, tube current, and increasing the slice collimation. There is no significant difference (p > 0.05) observed between the protocols and image metrics.
Collapse
|
7
|
Matsunaga Y, Haba T, Kobayashi M, Suzuki S, Asada Y, Chida K. Fetal radiation dose of four tube voltages in abdominal CT examinations during pregnancy: A phantom study. J Appl Clin Med Phys 2021; 22:178-184. [PMID: 33449434 PMCID: PMC7882097 DOI: 10.1002/acm2.13171] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2020] [Revised: 10/29/2020] [Accepted: 12/17/2020] [Indexed: 11/05/2022] Open
Abstract
This study aimed to compare the dose and noise level of four tube voltages in abdominal computerized tomography (CT) examinations in different abdominal circumference sizes of pregnant women. Fetal radiation doses were measured with two anthropomorphic pregnant phantoms and real-time dosimeters of photoluminescence sensors using four tube voltages for abdominal CT. The noise level was measured at the abdomen of two anthropomorphic pregnant phantoms. In the large pregnant phantom, the mean fetal doses performed using 120 and 135 kV were statistically significantly lower than the lower tube voltages (P < 0.05). In the small pregnant phantom, the mean fetal dose performed by 100, 120, and 135 kV was significantly lower than the lowest tube voltage tested (P < 0.05). The ratios of the peripheral mean dose to the centric mean dose showed that the ratios of 80 kV were the highest and those for 135 kV were the lowest in both pregnant phantoms. The ratios of the peripheral mean dose to the centric mean dose decreased as the tube voltage increased. Compared with low tube voltages, high tube voltages such as 120 and 135 kV could reduce radiation doses to the fetus without compromising the image uniformity in abdominal CT examinations during pregnancy. On low tube voltage protocols, the dose near the maternal skin surface may be increased in large pregnant women because of reduced penetration of the x rays.
Collapse
Affiliation(s)
- Yuta Matsunaga
- Department of ImagingNagoya Kyoritsu HospitalNagoyaAichiJapan
- Department of Radiological TechnologyFaculty of Health SciencesTohoku University Graduate School of MedicineSendaiMiyagiJapan
| | - Tomonobu Haba
- School of Health SciencesFujita Health UniversityToyoakeAichiJapan
| | | | - Shoichi Suzuki
- School of Health SciencesFujita Health UniversityToyoakeAichiJapan
| | - Yasuki Asada
- School of Health SciencesFujita Health UniversityToyoakeAichiJapan
| | - Koichi Chida
- Department of Radiological TechnologyFaculty of Health SciencesTohoku University Graduate School of MedicineSendaiMiyagiJapan
| |
Collapse
|
8
|
Muhammad N, Sabarudin A, Ismail N, Karim M. A systematic review and meta-analysis of radiation dose exposure from computed tomography examination of thorax-abdomen-pelvic regions among paediatric population. Radiat Phys Chem Oxf Engl 1993 2021. [DOI: 10.1016/j.radphyschem.2020.109148] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
9
|
Muhammad NA, Abdul Karim MK, Abu Hassan H, Ahmad Kamarudin M, Ding Wong JH, Ng KH. Diagnostic Reference Level of Radiation Dose and Image Quality among Paediatric CT Examinations in A Tertiary Hospital in Malaysia. Diagnostics (Basel) 2020; 10:E591. [PMID: 32823818 PMCID: PMC7460376 DOI: 10.3390/diagnostics10080591] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2020] [Revised: 07/22/2020] [Accepted: 07/22/2020] [Indexed: 01/27/2023] Open
Abstract
Pediatrics are more vulnerable to radiation and are prone to dose compared to adults, requiring more attention to computed tomography (CT) optimization. Hence, diagnostic reference levels (DRLs) have been implemented as part of optimization process in order to monitor CT dose and diagnostic quality. The noise index has recently been endorsed to be included as a part of CT optimization in the DRLs report. In this study, we have therefore set local DRLs for pediatric CT examination with a noise index as an indicator of image quality. One thousand one hundred and ninety-two (1192) paediatric patients undergoing CT brain, CT thorax and CT chest-abdomen-pelvis (CAP) examinations were analyzed retrospectively and categorized into four age groups; group 1 (0-1 year), group 2 (1-5 years), group 3 (5-10 years) and group 4 (10-15 years). For each group, data such as the volume-weighted CT dose index (CTDIvol), dose-length product (DLP) and the effective dose (E) were calculated and DRLs for each age group set at 50th percentile were determined. Both CT dose and image noise values between age groups have differed significantly with p-value < 0.05. The highest CTDIvol and DLP values in all age groups with the lowest noise index value reported in the 10-15 age group were found in CT brain examination. In conclusion, there was a significant variation in doses and noise intensity among children of different ages, and the need to change specific parameters to fit the clinical requirement.
Collapse
Affiliation(s)
- Nor Azura Muhammad
- Department of Physics, Faculty of Science, Universiti Putra Malaysia, Serdang 43400, Selangor, Malaysia; (N.A.M.); (M.A.K.)
| | - Muhammad Khalis Abdul Karim
- Department of Physics, Faculty of Science, Universiti Putra Malaysia, Serdang 43400, Selangor, Malaysia; (N.A.M.); (M.A.K.)
- Centre of Diagnostic Nuclear Imaging, Faculty of Medicine, Universiti Putra Malaysia, Serdang 43400, Selangor, Malaysia
| | - Hasyma Abu Hassan
- Department of Imaging, Faculty of Medicine and Health Sciences, Universiti Putra Malaysia, Serdang 43400, Selangor, Malaysia;
| | - Mazliana Ahmad Kamarudin
- Department of Physics, Faculty of Science, Universiti Putra Malaysia, Serdang 43400, Selangor, Malaysia; (N.A.M.); (M.A.K.)
| | - Jeannie Hsiu Ding Wong
- Department of Biomedical Imaging, University Malaya Medical Centre, Petaling Jaya 59100, Kuala Lumpur, Malaysia; (J.H.D.W.); (K.H.N.)
| | - Kwan Hoong Ng
- Department of Biomedical Imaging, University Malaya Medical Centre, Petaling Jaya 59100, Kuala Lumpur, Malaysia; (J.H.D.W.); (K.H.N.)
- Department of Medical Imaging and Radiological Sciences, College of Health Sciences, Kaohsiung Medical University, Kaohsiung 80708, Taiwan
| |
Collapse
|
10
|
Meng D, Cui X, Bai C, Yu Z, Xin L, Fu Y, Wang S, Du Y, Gao Z, Ye Z. Application of low-concentration contrast agents and low-tube-voltage computed tomography to chest enhancement examinations: A multicenter prospective study. Sci Prog 2020; 103:36850419892193. [PMID: 31791209 PMCID: PMC10358470 DOI: 10.1177/0036850419892193] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
To evaluate the influence of low-concentration contrast agents and low-tube-voltage computed tomography on chest enhancement examinations, we conducted a multicenter prospective study. A total of 216 inpatients enrolled from 12 different hospitals were randomly divided into four groups: A: voltage, 120 kVp; iohexol, 350 mgI/mL; B: voltage, 100 kVp, iohexol, 350 mgI/mL; C: voltage, 120 kVp, iodixanol, 270 mgI/mL; and D: voltage, 100 kVp, iodixanol, 270 mgI/mL. Subjective image quality was assessed by two radiologists and compared by weighted kappa test. The objective image scores, scanning radiation doses, and pathological coincidence rates were analyzed. There were no significant differences in gender, age, height, weight, and body mass index between the four groups (p > 0.05). The consistency of the radiologists' ratings were good, with kappa value ranging from 0.736 (95% confidence interval: 0.54-0.933) to 0.809 (95% confidence interval: 0.65-0.968), and there was no difference in subjective image score between the four groups. The computed tomography value of group D had no difference with group A. The volume computed tomography dose index, dose length product, and effective dose of group D (6.93 ± 3.03, 241.55 ± 104.75, and 3.38 ± 1.47, respectively) were all significantly lower than those of group A (10.30 ± 4.37, 359.70 ± 152.65, and 5.04 ± 2.14, respectively). There was no significant difference in the imaging diagnosis accuracy rate between the four groups (p > 0.05). The results indicated that low-concentration contrast agents (270 mgI/mL) and low-tube-voltage (100 kVp) computed tomography can not only decrease radiation dose but also guarantee the image quality and meet the needs of imaging diagnosis in chest enhancement examinations, which make it possible for its generalization and application.
Collapse
Affiliation(s)
- Donghua Meng
- Department of Radiology, Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Center for Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin’s Clinical Research Center for Cancer, Tianjin, China
| | - Xiaonan Cui
- Department of Radiology, Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Center for Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin’s Clinical Research Center for Cancer, Tianjin, China
| | - Changsen Bai
- Department of Laboratory, Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Center for Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin’s Clinical Research Center for Cancer, Tianjin, China
| | - Zhongwen Yu
- Department of Radiology, China Resources Wuhan Iron and Steel General Hospital, Wuhan, China
| | - Lei Xin
- Department of Radiology, Shanxi Cancer Hospital, Taiyuan, China
| | - Yufei Fu
- Department of Radiology, Edong Medical Group Central Hospital, Huangshi, China
| | | | - Yu Du
- Department of Radiology, The Fourth Hospital of Hebei Medical University, Shijiazhuang, China
| | - Zhipeng Gao
- Department of Radiology, Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Center for Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin’s Clinical Research Center for Cancer, Tianjin, China
| | - Zhaoxiang Ye
- Department of Radiology, Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Center for Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin’s Clinical Research Center for Cancer, Tianjin, China
| |
Collapse
|
11
|
Yan C, Liang C, Xu J, Wu Y, Xiong W, Zheng H, Xu Y. Ultralow-dose CT with knowledge-based iterative model reconstruction (IMR) in evaluation of pulmonary tuberculosis: comparison of radiation dose and image quality. Eur Radiol 2019; 29:5358-5366. [PMID: 30927099 DOI: 10.1007/s00330-019-06129-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2018] [Revised: 02/06/2019] [Accepted: 03/06/2019] [Indexed: 12/19/2022]
Abstract
OBJECTIVES To evaluate the image quality of ultralow-dose computed tomography (ULDCT) reconstructed with knowledge-based iterative model reconstruction (IMR) in patients with pulmonary tuberculosis (TB). METHODS This IRB-approved prospective study enrolled 59 consecutive patients (mean age, 43.9 ± 16.6 years; F:M 18:41) with known or suspected pulmonary TB. Patients underwent a low-dose CT (LDCT) using automatic tube current modulation followed by an ULDCT using fixed tube current. Raw image data were reconstructed with filtered-back projection (FBP), hybrid iterative reconstruction (iDose), and IMR. Objective measurements including CT attenuation, image noise, and contrast-to-noise ratio (CNR) were assessed and compared using repeated-measures analysis of variance. Overall image quality and visualization of normal and pathological findings were subjectively scored on a five-point scale. Radiation output and subjective scores were compared by the paired Student t test and Wilcoxon signed-rank test, respectively. RESULTS Compared with FBP and iDose, IMR yielded significantly lower noise and higher CNR values at both dose levels (p < 0.01). Subjective ratings for pathological findings including centrilobular nodules, consolidation, tree-in-bud, and cavity were significantly better with ULDCT IMR images than those with LDCT iDose images (p < 0.01), but blurred edges were observed. With IMR implementation, a 59% reduction of the mean effective dose was achieved with ULDCT (0.28 ± 0.02 mSv) compared with LDCT (0.69 ± 0.15 mSv) without impairing image quality (p < 0.001). CONCLUSIONS IMR offers considerable noise reduction and improvement in image quality for patients with pulmonary TB undergoing chest ULDCT at an effective dose of 0.28 mSv. KEY POINTS • Radiation dose is a major concern for tuberculosis patients requiring repeated follow-up CT. • IMR allows substantial radiation dose reduction in chest CT without compromising image quality. • ULDCT reconstructed with IMR allows accurate depiction of CT features of pulmonary tuberculosis.
Collapse
Affiliation(s)
- Chenggong Yan
- Department of Medical Imaging Center, Nanfang Hospital, Southern Medical University, No. 1838 Guangzhou Avenue North, Guangzhou, 510515, Guangdong, People's Republic of China
| | - Chunyi Liang
- Department of Medical Imaging Center, Nanfang Hospital, Southern Medical University, No. 1838 Guangzhou Avenue North, Guangzhou, 510515, Guangdong, People's Republic of China
| | - Jun Xu
- Department of Hematology, Nanfang Hospital, Southern Medical University, No. 1838 Guangzhou Avenue North, Guangzhou, 510515, Guangdong, People's Republic of China
| | - Yuankui Wu
- Department of Medical Imaging Center, Nanfang Hospital, Southern Medical University, No. 1838 Guangzhou Avenue North, Guangzhou, 510515, Guangdong, People's Republic of China
| | - Wei Xiong
- Department of Medical Imaging Center, Nanfang Hospital, Southern Medical University, No. 1838 Guangzhou Avenue North, Guangzhou, 510515, Guangdong, People's Republic of China
| | - Huan Zheng
- Department of Medical Imaging Center, Nanfang Hospital, Southern Medical University, No. 1838 Guangzhou Avenue North, Guangzhou, 510515, Guangdong, People's Republic of China
| | - Yikai Xu
- Department of Medical Imaging Center, Nanfang Hospital, Southern Medical University, No. 1838 Guangzhou Avenue North, Guangzhou, 510515, Guangdong, People's Republic of China.
| |
Collapse
|
12
|
Matsunaga Y, Chida K, Kondo Y, Kobayashi K, Kobayashi M, Minami K, Suzuki S, Asada Y. Diagnostic reference levels and achievable doses for common computed tomography examinations: Results from the Japanese nationwide dose survey. Br J Radiol 2019; 92:20180290. [PMID: 30306794 PMCID: PMC6404832 DOI: 10.1259/bjr.20180290] [Citation(s) in RCA: 41] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2018] [Revised: 09/24/2018] [Accepted: 10/03/2018] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVE: To propose a new set of Japanese diagnostic reference levels (DRLs) and achievable doses (ADs) for 2017 and to verify the usefulness of Japanese DRLs (DRLs 2015) for CT, by investigating changes in the volume CT dose index (CTDIvol) from 2014 to 2017. METHODS: Detailed information on the CT scan parameters used throughout Japan were obtained by questionnaire survey. The CTDIvol and dose-length product for the 11 commonest adult and 6 commonest paediatric CT examinations were surveyed and compared with 2014 data and DRLs 2015. RESULTS: Evaluations of adult head (helical), and abdomen and pelvis without contrast agent, paediatric chest without contrast agent, and abdomen and pelvis without contrast agent showed a slightly lower mean CTDIvol in 2017 than in 2014 (t-test, p < 0.05). The interquartile range of CTDIvol for all 2017 examinations was lower than in 2014. CONCLUSIONS: This study verified the lower mean, 75th percentile, and interquartile range by investigating changes in the CTDIvol from 2014 to 2017. The DRLs 2015 contributed to CT radiation dose reduction. ADVANCES IN KNOWLEDGE: The widespread implementation of iterative reconstruction algorithms and low-tube voltage in CT scanners is likely to facilitate further reduction in the CT radiation dose used in Japan. Although radiological technologists may require further education on appropriate CTDIvol and DLP usage, the DRLs 2015 greatly contributed to the reduction of the CT radiation dose used in Japan.
Collapse
Affiliation(s)
| | - Koichi Chida
- Department of Radiological Technology, Faculty of Health Sciences, Tohoku University Graduate School of Medicine, Sendai, Japan
| | - Yuya Kondo
- Graduate school of Health Sciences, Fujita Health University, Toyoake, Japan
| | - Kenichi Kobayashi
- Department of Radiology, Fujita Health University Hospital, Toyoake, Japan
| | - Masanao Kobayashi
- Faculty of Radiological Technology, School of Health Science, Fujita Health University, Toyoake, Japan
| | - Kazuyuki Minami
- Faculty of Radiological Technology, School of Health Science, Fujita Health University, Toyoake, Japan
| | - Shoichi Suzuki
- Faculty of Radiological Technology, School of Health Science, Fujita Health University, Toyoake, Japan
| | - Yasuki Asada
- Faculty of Radiological Technology, School of Health Science, Fujita Health University, Toyoake, Japan
| |
Collapse
|
13
|
Bombiński P, Brzewski M, Warchol S, Biejat A, Banasiuk M, Gołębiowski M. Influence of diuretic (furosemide) on contrast medium distribution in computed tomography urography of high-grade hydronephrosis in children. Cent European J Urol 2019; 71:476-480. [PMID: 30680245 PMCID: PMC6338812 DOI: 10.5173/ceju.2018.1742] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2018] [Revised: 11/15/2018] [Accepted: 11/16/2018] [Indexed: 12/05/2022] Open
Abstract
Introduction Diuretics improve visualization of the urinary tract in computed tomography urography in adults, as well as in magnetic resonance urography in adults and children. Also, diuretics can help to diagnose upper urinary tract obstruction in intravenous urography, ultrasonography or dynamic scintigraphy. However, there are still missing data on evaluation of furosemide usefulness in computed tomography urography examinations in children with suspected congenital anomalies of the urinary tracts. The aim of this study was to compare the homogeneity of contrast medium distribution in high-grade hydronephrosis in pediatric computed tomography urographies performed with and without use of diuretic (furosemide). Materials and method We have restrospectively analyzed computed tomography urography image series performed in the Department of Pediatric Radiology, in children with suspected congenital anomalies of the kidney and the urinary tract. Kidney units with high-grade hydronephrosis were divided in two groups: non-furosemide (n = 25) and furosemide (n = 28) group, where diuretic in dose 1 mg/kg, with maximum 20 mg, was administered intravenously 3–5 min before contrast medium administration. Subjective image quality and diagnostic confidence were evaluated by two independent radiologists and compared between study groups. Results There were no significant differences in subjective image quality and diagnostic confidence between furosemide and non-furosemide groups. Conclusions Addition of furosemide to computed tomography urography does not improve homogeneity of contrast medium distribution in hydronephrotic kidneys in children.
Collapse
Affiliation(s)
| | - Michał Brzewski
- Department of Pediatric Radiology, Medical University of Warsaw, Warsaw, Poland
| | - Stanislaw Warchol
- Department of Pediatric Surgery and Urology, Medical University of Warsaw, Warsaw, Poland
| | - Agnieszka Biejat
- Department of Pediatric Radiology, Medical University of Warsaw, Warsaw, Poland
| | - Marcin Banasiuk
- Department of Pediatric Gastroenterology and Nutrition, Medical University of Warsaw, Warsaw, Poland
| | - Marek Gołębiowski
- 1 Department of Clinical Radiology, Medical University of Warsaw, Warsaw, Poland
| |
Collapse
|
14
|
Böning G, Kahn JF, Kaul D, Rotzinger R, Freyhardt P, Pavel M, Streitparth F. CT follow-up in patients with neuroendocrine tumors (NETs): combined radiation and contrast dose reduction. Acta Radiol 2018; 59:517-526. [PMID: 28786299 DOI: 10.1177/0284185117726101] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Background Frequent computed tomography (CT) follow-ups involve significant radiation related risks for patients with low-grade neuroendocrine tumors (NETs). Contrast agent (CA) application is essential for diagnostic evidence and has additional risks especially in patients with limited renal function. Purpose To investigate if a combination of dose and contrast agent (CA) reduction affects image quality and diagnostic evidence in neuroendocrine tumor (NET) patients. Material and Methods A total of 51 NET patients were enrolled in the study and 153 CT scans were analyzed. Patients underwent a baseline CT scan (A = 120 kVp, filtered back projection [FBP]) and two follow-up CTs (B = 120 kVp, adaptive statistical iterative reconstruction [ASIR] 40%; C1 = 100 kVp, ASIR 40%; C2 = 100 kVp, ASIR 60%; the latter two protocols were applied with a 30% reduction in CA volume). We evaluated image quality and applied dose. Results In C1/2, the combination of low kV (100 kVp) with ASIR 40%/60% reduced the mean applied dose significantly by 28% compared to B and by 57% compared to A. Signal-to-noise ratio (SNR) and contrast-to-noise ratios (CNR) of tumor to liver/muscle were significantly increased by using C1/2 compared to B and A. With respect to subjective image quality, a slight loss of diagnostic confidence in C1 could be counterbalanced by the higher ASIR blending in C2. Conclusion Combined dose reduction techniques can be used to reduce radiation dose and CA volume without sacrificing image quality and diagnostic confidence in staging CT of NET patients.
Collapse
Affiliation(s)
- G Böning
- Department of Radiology Charité, Humboldt-University Medical School, Berlin, Germany
| | - JF Kahn
- Department of Radiology Charité, Humboldt-University Medical School, Berlin, Germany
| | - D Kaul
- Department of Radiation Oncology Charité, Humboldt-University Medical School, Berlin, Germany
| | - R Rotzinger
- Department of Radiology Charité, Humboldt-University Medical School, Berlin, Germany
| | - P Freyhardt
- Department of Radiology Charité, Humboldt-University Medical School, Berlin, Germany
| | - M Pavel
- Department of Gastroenterology Charité, Humboldt-University Medical School, Berlin, Germany
| | - F Streitparth
- Department of Radiology Charité, Humboldt-University Medical School, Berlin, Germany
| |
Collapse
|
15
|
Computed tomography urography with iterative reconstruction algorithm in congenital urinary tract abnormalities in children - association of radiation dose with image quality. Pol J Radiol 2018; 83:e175-e182. [PMID: 30627232 PMCID: PMC6323543 DOI: 10.5114/pjr.2018.75808] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2018] [Accepted: 03/19/2018] [Indexed: 01/20/2023] Open
Abstract
Purpose To assess the extent to which a radiation dose can be lowered without compromising image quality and diagnostic confidence in congenital urinary tract abnormalities in children by using a CT scanner with an iterative reconstruction algorithm. Material and methods 120 CT urography image series were analysed retrospectively. Image series were divided into four study groups depending on effective radiation dose (group 1: 0.8-2 mSv; group 2: 2-4 mSv; group 3: 4-6 mSv; group 4: 6-11 mSv). Objective and subjective image quality were investigated. In objective analysis, measurements of attenuation and standard deviation (SD) in five regions of interest (ROIs) were performed in 109 excretory image series, and image noise was evaluated. In subjective analysis, two independent radiologists evaluated 138 kidney units for subjective image quality and diagnostic confidence. Results There were no significant differences in image noise in objective evaluation between the following study groups: 2 vs. 3 and 3 vs. 4 in all ROIs (with the only exception in spleen SD measurement between study groups 2 vs. 3), while there was significantly more image noise in group 2 in comparison to group 4. For all other ROIs in all study groups, there was more image noise on lower dose images. There were no significant differences in pairwise comparisons between study groups in subjective image quality. Diagnostic confidence was not significantly different between all study groups. Conclusions Low-dose CT urography can be a valuable method in congenital urinary tract abnormalities in children. Despite poorer image quality, diagnostic confidence is not significantly compromised in examinations performed with lower radiation doses.
Collapse
|
16
|
A comparison study of size-specific dose estimate calculation methods. Pediatr Radiol 2018; 48:56-65. [PMID: 28951948 DOI: 10.1007/s00247-017-3986-7] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/18/2017] [Revised: 06/20/2017] [Accepted: 09/06/2017] [Indexed: 10/18/2022]
Abstract
BACKGROUND The size-specific dose estimate (SSDE) has emerged as an improved metric for use by medical physicists and radiologists for estimating individual patient dose. Several methods of calculating SSDE have been described, ranging from patient thickness or attenuation-based (automated and manual) measurements to weight-based techniques. OBJECTIVE To compare the accuracy of thickness vs. weight measurement of body size to allow for the calculation of the size-specific dose estimate (SSDE) in pediatric body CT. MATERIALS AND METHODS We retrospectively identified 109 pediatric body CT examinations for SSDE calculation. We examined two automated methods measuring a series of level-specific diameters of the patient's body: method A used the effective diameter and method B used the water-equivalent diameter. Two manual methods measured patient diameter at two predetermined levels: the superior endplate of L2, where body width is typically most thin, and the superior femoral head or iliac crest (for scans that did not include the pelvis), where body width is typically most thick; method C averaged lateral measurements at these two levels from the CT projection scan, and method D averaged lateral and anteroposterior measurements at the same two levels from the axial CT images. Finally, we used body weight to characterize patient size, method E, and compared this with the various other measurement methods. Methods were compared across the entire population as well as by subgroup based on body width. RESULTS Concordance correlation (ρc) between each of the SSDE calculation methods (methods A-E) was greater than 0.92 across the entire population, although the range was wider when analyzed by subgroup (0.42-0.99). When we compared each SSDE measurement method with CTDIvol, there was poor correlation, ρc<0.77, with percentage differences between 20.8% and 51.0%. CONCLUSION Automated computer algorithms are accurate and efficient in the calculation of SSDE. Manual methods based on patient thickness provide acceptable dose estimates for pediatric patients <30 cm in body width. Body weight provides a quick and practical method to identify conversion factors that can be used to estimate SSDE with reasonable accuracy in pediatric patients with body width ≥20 cm.
Collapse
|
17
|
Affiliation(s)
- Yangyang R Yu
- Division of Pediatric Surgery, Michael E. DeBakey Department of Surgery, Texas Children's Hospital, Baylor College of Medicine, 6701 Fannin Street, Suite 1210, Houston, TX 77030, USA
| | - Sohail R Shah
- Division of Pediatric Surgery, Michael E. DeBakey Department of Surgery, Texas Children's Hospital, Baylor College of Medicine, 6701 Fannin Street, Suite 1210, Houston, TX 77030, USA.
| |
Collapse
|
18
|
Badru F, Piening N, To A, Xu P, Fitzpatrick C, Chatoorgoon K, Villalona G, Greenspon J. Imaging for acute appendicitis at nonpediatric centers exposes children to excess radiation. J Surg Res 2017; 216:201-206. [DOI: 10.1016/j.jss.2017.04.029] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2016] [Revised: 04/04/2017] [Accepted: 04/27/2017] [Indexed: 12/29/2022]
|
19
|
Usefulness of a Low Tube Voltage: Knowledge-Based Iterative Model Reconstruction Algorithm for Computed Tomography Venography. J Comput Assist Tomogr 2017; 41:811-816. [PMID: 28448403 DOI: 10.1097/rct.0000000000000600] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES The objective of this study was to evaluate the use of 80-kVp scans with knowledge-based iterative model reconstruction (IMR) for computed tomography venography (CTV). METHODS This prospective study received institutional review board approval; a previous informed consent was obtained from all participants. We enrolled 30 patients with suspected deep venous thrombosis or pulmonary embolism who were to undergo 80-kVp CTV studies. The images were reconstructed with filtered back projection (FBP), hybrid iterative reconstruction (HIR), and IMR. The venous attenuation, image noise, and contrast-to-noise ratio at the iliac, femoral, and popliteal veins were compared on FBP, HIR, and IMR images. We performed qualitative image analysis (image noise, image contrast, image sharpness, streak artifacts, and overall image quality) of the 3 reconstruction methods and measured their reconstruction times. RESULTS There was no significant difference in venous attenuation among the 3 reconstruction methods (P > 0.05). On IMR images, the image noise was lowest at all 3 venous locations, and the contrast-to-noise ratio was highest. Qualitative evaluation scores were also highest for IMR images. The reconstruction time for FBP, HIR, and IMR imaging was 25.4 ± 1.9 seconds, 43.3 ± 3.3 seconds, and 78.7 ± 6.0 seconds, respectively. CONCLUSIONS At clinically acceptable reconstruction times, 80-kVp CTV using the IMR technique yielded better qualitative and quantitative image quality than HIR and FBP.
Collapse
|
20
|
Abstract
Appendicitis is a common cause of abdominal pain in children. The diagnosis and treatment of the disease have undergone major changes in the past two decades, primarily as a result of the application of an evidence-based approach. Data from several randomized controlled trials, large database studies, and meta-analyses have fundamentally affected patient care. The best diagnostic approach is a standardized clinical pathway with a scoring system and selective imaging. Non-operative management of simple appendicitis is a reasonable option in selected cases, with the caveat that data in children remain limited. A minimally invasive (laparoscopic) appendectomy is the current standard in US and European children's hospitals. This article reviews the current 'state of the art' in the evaluation and management of pediatric appendicitis.
Collapse
Affiliation(s)
- Rebecca M Rentea
- Department of Surgery, Children's Mercy Hospital, 2401 Gillham Road, Kansas, MO, 64108, USA.
| | - Shawn D St Peter
- Department of Surgery, Children's Mercy Hospital, 2401 Gillham Road, Kansas, MO, 64108, USA
| | - Charles L Snyder
- Department of Surgery, Children's Mercy Hospital, 2401 Gillham Road, Kansas, MO, 64108, USA
| |
Collapse
|
21
|
Hou QR, Gao W, Sun AM, Wang Q, Qiu HS, Wang F, Hu LW, Li JY, Zhong YM. A prospective evaluation of contrast and radiation dose and image quality in cardiac CT in children with complex congenital heart disease using low-concentration iodinated contrast agent and low tube voltage and current. Br J Radiol 2016; 90:20160669. [PMID: 27925466 DOI: 10.1259/bjr.20160669] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVE To the assess image quality, contrast dose and radiation dose in cardiac CT in children with congenital heart disease (CHD) using low-concentration iodinated contrast agent and low tube voltage and current in comparison with standard dose protocol. METHODS 110 patients with CHD were randomized to 1 of the 2 scan protocols: Group A (n = 45) with 120 mA tube current and contrast agent of 270 mgI/ml in concentration (Visipaque™; GE Healthcare Ireland, Co., Cork, UK); and Group B (n = 65) with the conventional 160 mA and 370 mgI/ml concentration contrast (Iopamiro®; Shanghai Bracco Sine Pharmaceutical Corp Ltd, Shanghai, China). Both groups used 80 kVp tube voltage and were reconstructed with 70% adaptive statistical iterative reconstruction algorithm. The CT value and noise in aortic arch were measured and the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. A five-point scale was used to subjectively evaluate image quality. Contrast and radiation dose were recorded. RESULTS There was no difference in age and weight between the two groups (all p > 0.05). The iodine load and radiation dose in Group A were statistically lower (3976 ± 747 mgI vs 5763 ± 1018 mgI in iodine load and 0.60 ± 0.08 mSv vs 0.77 ± 0.10 mSv in effective dose; p < 0.001). However, image noise, CT value, CNR, SNR and subjective image quality for the two groups were similar (all p > 0.05), and with good agreement between the two observers. Comparing the surgery results, the diagnostic accuracy for extracardiac and intracardiac defects for Group A was 96% and 92%, respectively, while the corresponding numbers for Group B were 95% and 93%. CONCLUSION Compared with the standard dose protocol, the use of low tube voltage (80 kVp), low tube current (120 mA) and low-concentration iodinated contrast agent (270 mgI/ml) enables a reduction of 30% in iodine load and 22% in radiation dose while maintaining compatible image quality and diagnostic accuracy. Advances in knowledge: The new cardiac CT scanning protocol can largely reduce the adverse effects of radiation and contrast media to children. Meanwhile, it also can be used effectively to examine complex CHD.
Collapse
Affiliation(s)
- Qiao-Ru Hou
- 1 Diagnostic Imaging Center, Shanghai Children's Medical Center, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Wei Gao
- 2 Department of Pediatric Cardiology, Shanghai Children's Medical Center, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Ai-Min Sun
- 1 Diagnostic Imaging Center, Shanghai Children's Medical Center, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Qian Wang
- 1 Diagnostic Imaging Center, Shanghai Children's Medical Center, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Hai-Sheng Qiu
- 1 Diagnostic Imaging Center, Shanghai Children's Medical Center, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Fang Wang
- 3 Department of Radiology, Wuhan Medical and Healthcare Center for Woman and Children, Hubei, China
| | - Li-Wei Hu
- 1 Diagnostic Imaging Center, Shanghai Children's Medical Center, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Jian-Ying Li
- 4 CT Research Center, GE Healthcare, Shanghai, China
| | - Yu-Min Zhong
- 1 Diagnostic Imaging Center, Shanghai Children's Medical Center, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| |
Collapse
|
22
|
Wang X, Zhong Y, Hu L, Xue L, Shi M, Qiu H, Li J. A prospective evaluation of the contrast, radiation dose and image quality of contrast-enhanced CT scans of paediatric abdomens using a low-concentration iodinated contrast agent and low tube voltage combined with 70% ASIR algorithm. Int J Clin Pract 2016; 70 Suppl 9B:B16-21. [PMID: 27577509 DOI: 10.1111/ijcp.12853] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/22/2015] [Accepted: 06/15/2016] [Indexed: 10/21/2022] Open
Abstract
PURPOSE To quantitatively and subjectively assess the image quality of and radiation dose for an abdominal enhanced computed tomography (CT) scan with a low tube voltage and a low concentration of iodinated contrast agent in children. METHODS Forty-eight patients were randomised to one of the two following protocols: Group A (n=24, mean age 46.96±44.65 months, mean weight 15.71±9.11 kg, BMI 16.48±2.40 kg/m(2) ) and Group B (n=24, mean age 41.33±44.59 months, mean weight 18.15±17.67 kg, BMI 17.50±3.73 kg/m(2) ). Group A: 80 kVp tube voltage, 270 mg iodine (I)/mL contrast agent (Visipaque, GE Healthcare) and images were reconstructed using 70% adaptive statistical iterative reconstruction (ASIR). Group B: 100 kVp tube voltage, 370 mg I/mL contrast agent (Iopamiro, Bracco) and images were reconstructed using 50% ASIR. The volume of the contrast agent was 1.30 mL/kg in both Groups A and B. The degree of enhancement and noise in the abdominal aorta (AO) in the arterial phase (AP) and the portal vein (PV) in the portal venous phase (PVP) was measured; while the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) for the AO and PV were calculated. A 5-point scale was used to subjectively evaluate the image quality and image noise by two radiologists with more than 10 years of experience. Dose-length product (DLP) (mGy-cm) and CTDIvol (mGy) were calculated. Objective measurements and subjective quality scores for the two groups were compared using paired t-tests and Mann-Whitney U tests, respectively. RESULTS There was no significant difference in age, weight or body mass index (BMI) between the two groups (all P>.5). The iodine load in Group A (5517.3±3197.2 mg I) was 37% lower than that in Group B (8772.1±8474.6 mg I), although there was no significant difference between them (P=.111). The DLP and the CT dose index (CTDIvol ) for Group A were also lower than for Group B, but were not statistically significantly different (DLP, 104 mGy-cm±45.81 vs 224.5 mGy-cm±45.83; CTDIvol, 1.44 mGy±0.50 vs 2.08 mGy±1.87, all P>.05). The mean arterial and portal venous enhancement (255.33 HU±83.42, 146.41 HU±23.45, respectively), noise (AP 14.96 HU±2.09, PVP 16.30 HU±3.21), CNRs (AO 14.54±7.12, PV 5.07±1.73) and SNRs (AO 20.76±6.76, PV 12.43±3.24) for Group A were similar to Group B (enhancement: 226.55 HU±77.71, 138.69 HU±33.22; noise: 14.92 HU±3.12, 15.36 HU±3.48; CNRs: 12.96±7.14, 5.16±2.28; SNRs: 19.13±7.30, 12.69±4.22; all P>.05). The mean scores of the quality of the AP and PVP images in Group B were 4.31±0.53 and 4.35±0.52, respectively, while the scores obtained in Group A were 4.29±0.51 and 4.25±0.51; there were no statistically significant differences between the two groups. CONCLUSION The scanning protocol using a low tube voltage (80 kVp) together with 70% ASIR and a low-concentration iodinated contrast agent (270 mg I/mL) enables a 37% reduction in iodine load and a 30% reduction in radiation dose while maintaining compatible image quality.
Collapse
Affiliation(s)
- Xiaoxia Wang
- Diagnostic Imaging Center, Shanghai Children's Medical Center affiliated with Shanghai Jiao Tong University Medical School, Shanghai, China
| | - Yumin Zhong
- Diagnostic Imaging Center, Shanghai Children's Medical Center affiliated with Shanghai Jiao Tong University Medical School, Shanghai, China
| | - Liwei Hu
- Diagnostic Imaging Center, Shanghai Children's Medical Center affiliated with Shanghai Jiao Tong University Medical School, Shanghai, China
| | - Lianyan Xue
- Diagnostic Imaging Center, Shanghai Children's Medical Center affiliated with Shanghai Jiao Tong University Medical School, Shanghai, China
| | - Meihua Shi
- Diagnostic Imaging Center, Shanghai Children's Medical Center affiliated with Shanghai Jiao Tong University Medical School, Shanghai, China
| | - Haisheng Qiu
- Diagnostic Imaging Center, Shanghai Children's Medical Center affiliated with Shanghai Jiao Tong University Medical School, Shanghai, China
| | - Jianying Li
- CT Research Center, GE Healthcare China, Shanghai, China
| |
Collapse
|
23
|
Kok M, Mihl C, Hendriks BMF, Altintas S, Kietselaer BLJH, Wildberger JE, Das M. Optimizing contrast media application in coronary CT angiography at lower tube voltage: Evaluation in a circulation phantom and sixty patients. Eur J Radiol 2016; 85:1068-74. [PMID: 27161054 DOI: 10.1016/j.ejrad.2016.03.022] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2015] [Revised: 02/09/2016] [Accepted: 03/20/2016] [Indexed: 01/11/2023]
Affiliation(s)
- Madeleine Kok
- Department of Radiology, Maastricht University Medical Center, The Netherlands; CARIM, School for Cardiovascular Diseases, Maastricht University Medical Center, Maastricht, The Netherlands.
| | - Casper Mihl
- Department of Radiology, Maastricht University Medical Center, The Netherlands; CARIM, School for Cardiovascular Diseases, Maastricht University Medical Center, Maastricht, The Netherlands.
| | - Babs M F Hendriks
- Department of Radiology, Maastricht University Medical Center, The Netherlands.
| | - Sibel Altintas
- CARIM, School for Cardiovascular Diseases, Maastricht University Medical Center, Maastricht, The Netherlands; Department of Cardiology, Maastricht University Medical Center, The Netherlands.
| | - Bas L J H Kietselaer
- Department of Radiology, Maastricht University Medical Center, The Netherlands; CARIM, School for Cardiovascular Diseases, Maastricht University Medical Center, Maastricht, The Netherlands; Department of Cardiology, Maastricht University Medical Center, The Netherlands.
| | - Joachim E Wildberger
- Department of Radiology, Maastricht University Medical Center, The Netherlands; CARIM, School for Cardiovascular Diseases, Maastricht University Medical Center, Maastricht, The Netherlands.
| | - Marco Das
- Department of Radiology, Maastricht University Medical Center, The Netherlands; CARIM, School for Cardiovascular Diseases, Maastricht University Medical Center, Maastricht, The Netherlands.
| |
Collapse
|
24
|
Analysis of Image Gently Abdominal CT Protocol With the Use of Body Phantom Adapted to the Japanese Size. AJR Am J Roentgenol 2016; 207:183-9. [PMID: 27186974 DOI: 10.2214/ajr.15.15688] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE The purpose of this study was to analyze in detail the quality of abdominal CT images obtained using three protocols reported by Image Gently in 2014 (hereafter referred to as Image Gently 2014), with the use of a handmade body phantom adapted to typical body sizes of the Japanese population. Moreover, we converted the findings of Image Gently 2014 to match Japanese body sizes and referred to our converted findings as Image Gently Japan. MATERIALS AND METHODS We scanned each phantom in a mechanical isocenter in accordance with the Image Gently 2014 abdominal imaging protocol. We changed the tube current-exposure time product per rotation from 25 to 250 mAs. The bowtie filter was set with a minimum FOV for the phantom size. We then analyzed the volume CT dose index (CTDIvol)-measured CT number curve. We then used this CT number curve to calculate the CT number recommended by Image Gently Japan for each of the designated patient ages. RESULTS The CTDIvol-measured CT number curve showed that, as the CTDIvol increased with each age, image noise decreased. When we assumed that the CTDIvol value for adults was 20 mGy, the measured CT number was 12.5 HU. We then multiplied each reduction coefficient by age (neonate and 1, 5, 10, and 15 years). The measured CT numbers for Image Gently Japan performed to attain limited dose reduction were 3.0, 3.9, 4.9, 6.0, and 9.0 HU, respectively, whereas those for Image Gently Japan performed to achieve moderate dose reduction were 3.3, 4.3, 5.3, 6.3, and 9.3 HU, respectively, and those for Image Gently Japan performed to attain aggressive dose reduction were 4.1, 5.1, 5.8, 6.8, and 9.5 HU, respectively. CONCLUSION We analyzed the abdominal image quality demanded by Image Gently 2014, and we were able to adapt the results to the Japanese population and present them as our own Image Gently Japan recommendations. If the results of the present study become a foundation for scanning parameters for Japanese patients, we believe that they will eventually lead to a reduction in medical radiation exposure for this patient population.
Collapse
|
25
|
Shimonobo T, Funama Y, Utsunomiya D, Nakaura T, Oda S, Kiguchi M, Masuda T, Sakabe D, Yamashita Y, Awai K. Low-tube-voltage selection for non-contrast-enhanced CT: Comparison of the radiation dose in pediatric and adult phantoms. Phys Med 2016; 32:197-201. [DOI: 10.1016/j.ejmp.2015.12.005] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/29/2015] [Revised: 11/30/2015] [Accepted: 12/11/2015] [Indexed: 11/30/2022] Open
|
26
|
Boos J, Lanzman RS, Heusch P, Aissa J, Schleich C, Thomas C, Sawicki LM, Antoch G, Kröpil P. Does body mass index outperform body weight as a surrogate parameter in the calculation of size-specific dose estimates in adult body CT? Br J Radiol 2015; 89:20150734. [PMID: 26693878 DOI: 10.1259/bjr.20150734] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVE To assess the value of body mass index (BMI) in comparison with body weight as a surrogate parameter for the calculation of size-specific dose estimates (SSDEs) in thoracoabdominal CT. METHODS 401 CT examinations in 235 patients (196 chest, 205 abdomen; 95 females, 140 males; age 62.5 ± 15.0 years) were analysed in regard to weight, height and BMI (kg m(-2)). Effective diameter (Deff, cm) was assessed on axial CT images. The correlation between BMI, weight and Deff was calculated. SSDEs were calculated based on Deff, weight and BMI and lookup tables were developed. RESULTS Overall height, weight, BMI and Deff were 172.5 ± 9.9 cm, 79.5 ± 19.1 kg, 26.6 ± 5.6 kg m(-2) and 30.1 ± 4.3 cm, respectively. There was a significant correlation between Deff and BMI as well as weight (r = 0.85 and r = 0.84; p < 0.05, respectively). Correlation was significantly better for BMI in abdominal CT (r = 0.89 vs r = 0.84; p < 0.05), whereas it was better for weight in chest CT (r = 0.87 vs r = 0.81; p < 0.05). Surrogated SSDEs did not differ significantly from the reference standard with a median absolute relative difference of 4.2% per patient (interquartile range 25-75: 3.1-7.89, range 0-25.3%). CONCLUSION BMI and weight exhibit a significant correlation with Deff in adult patients and can be used as surrogates in the calculation of SSDEs. Using the herein-developed lookup charts, SSDEs can be calculated based on patients' weight and BMI. ADVANCES IN KNOWLEDGE In abdominal CT, BMI has a superior correlation with effective diameter compared with weight, whereas weight is superior in chest CT. Patients' BMI and weight can be used as surrogates in the calculation of SSDEs.
Collapse
Affiliation(s)
- Johannes Boos
- University Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Dusseldorf, Germany
| | - Rotem S Lanzman
- University Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Dusseldorf, Germany
| | - Philipp Heusch
- University Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Dusseldorf, Germany
| | - Joel Aissa
- University Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Dusseldorf, Germany
| | - Christoph Schleich
- University Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Dusseldorf, Germany
| | - Christoph Thomas
- University Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Dusseldorf, Germany
| | - Lino M Sawicki
- University Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Dusseldorf, Germany
| | - Gerald Antoch
- University Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Dusseldorf, Germany
| | - Patric Kröpil
- University Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Dusseldorf, Germany
| |
Collapse
|
27
|
Matsunaga Y, Kawaguchi A, Kobayashi K, Kobayashi M, Asada Y, Minami K, Suzuki S, Chida K. Effective radiation doses of CT examinations in Japan: a nationwide questionnaire-based study. Br J Radiol 2015; 89:20150671. [PMID: 26647804 PMCID: PMC4985214 DOI: 10.1259/bjr.20150671] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2015] [Revised: 11/28/2015] [Accepted: 12/07/2015] [Indexed: 02/01/2023] Open
Abstract
OBJECTIVE The aims of this study were to estimate the effective radiation doses from CT examinations of both adults and children in Japan and to study the impact of various scan parameters on the effective doses. METHODS A questionnaire, which contained detailed questions on the CT scan parameters employed, was distributed to 3000 facilities throughout Japan. For each scanner protocol, the effective doses for head (non-helical and helical), chest and upper abdomen acquisitions were estimated using ImPACT CT Patient Dosimetry Calculator software v. 1.0.4 (St George's Hospital, London, UK). RESULTS The mean effective doses for chest and abdominal examinations using 80-110 kV were significantly lower than those using 120 kV. However, there was no statistically significant difference in the mean effective doses for head scans between facilities employing 80-110 kV and 120 kV. In chest and abdominal examinations, the mean effective doses using CT scanners from Western manufacturers [Siemens (Forchheim, Germany), Philips (Eindhoven, Netherlands) and GE Medical Systems (Milwaukee, WI)] were significantly lower than those of examinations using Japanese scanners [Hitachi (Kashiwa, Japan) and Toshiba (Otawara, Tochigi, Japan)], except for in paediatric chest examinations. CONCLUSION The mean effective doses for adult head, chest and abdominal CT examinations were 2.9, 7.7 and 10.0 mSv, respectively, whereas the corresponding mean effective doses for paediatric examinations were 2.6, 7.1 and 7.7 mSv, respectively. ADVANCES IN KNOWLEDGE Facilities using CT scanners by Western manufacturers commonly adopt low-tube-voltage techniques, and low-tube-voltage CT may be useful for reducing the radiation doses to the patients, particularly for the body region.
Collapse
Affiliation(s)
- Yuta Matsunaga
- Department of Imaging, Nagoya Kyoritsu Hospital, Nagoya, Japan
- Graduate School of Medicine, Tohoku University, Sendai, Japan
| | - Ai Kawaguchi
- Graduate School of Medicine, Tohoku University, Sendai, Japan
- Department of Radiology, Toyota Memorial Hospital, Toyota, Japan
| | - Kenichi Kobayashi
- Department of Radiology, Fujita Health University Hospital, Toyoake, Japan
| | | | - Yasuki Asada
- School of Health Sciences, Fujita Health University, Toyoake, Japan
| | - Kazuyuki Minami
- School of Health Sciences, Fujita Health University, Toyoake, Japan
| | - Shoichi Suzuki
- School of Health Sciences, Fujita Health University, Toyoake, Japan
| | - Koichi Chida
- Graduate School of Medicine, Tohoku University, Sendai, Japan
| |
Collapse
|