1
|
Yasaka K, Abe O. Impact of rapid iodine contrast agent infusion on tracheal diameter and lung volume in CT pulmonary angiography measured with deep learning-based algorithm. Jpn J Radiol 2024; 42:1003-1011. [PMID: 38733470 PMCID: PMC11364558 DOI: 10.1007/s11604-024-01591-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2024] [Accepted: 05/04/2024] [Indexed: 05/13/2024]
Abstract
PURPOSE To compare computed tomography (CT) pulmonary angiography and unenhanced CT to determine the effect of rapid iodine contrast agent infusion on tracheal diameter and lung volume. MATERIAL AND METHODS This retrospective study included 101 patients who underwent CT pulmonary angiography and unenhanced CT, for which the time interval between them was within 365 days. CT pulmonary angiography was scanned 20 s after starting the contrast agent injection at the end-inspiratory level. Commercial software, which was developed based on deep learning technique, was used to segment the lung, and its volume was automatically evaluated. The tracheal diameter at the thoracic inlet level was also measured. Then, the ratios for the CT pulmonary angiography to unenhanced CT of the tracheal diameter (TDPAU) and both lung volumes (BLVPAU) were calculated. RESULTS Tracheal diameter and both lung volumes were significantly smaller in CT pulmonary angiography (17.2 ± 2.6 mm and 3668 ± 1068 ml, respectively) than those in unenhanced CT (17.7 ± 2.5 mm and 3887 ± 1086 ml, respectively) (p < 0.001 for both). A statistically significant correlation was found between TDPAU and BLVPAU with a correlation coefficient of 0.451 (95% confidence interval, 0.280-0.594) (p < 0.001). No factor showed a significant association with TDPAU. The type of contrast agent had a significant association for BLVPAU (p = 0.042). CONCLUSIONS Rapid infusion of iodine contrast agent reduced the tracheal diameter and both lung volumes in CT pulmonary angiography, which was scanned at end-inspiratory level, compared with those in unenhanced CT.
Collapse
Affiliation(s)
- Koichiro Yasaka
- Department of Radiology, The University of Tokyo Hospital, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan.
| | - Osamu Abe
- Department of Radiology, The University of Tokyo Hospital, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan
| |
Collapse
|
2
|
Yasaka K, Takahashi MM, Kurokawa M, Kubo T, Watanabe Y, Saigusa H, Abe O. Transient interruption of contrast on CT pulmonary angiography: effect of mid-inspiratory vs. end-inspiratory respiration command. Emerg Radiol 2024; 31:331-340. [PMID: 38632154 PMCID: PMC11129981 DOI: 10.1007/s10140-024-02227-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2024] [Accepted: 03/28/2024] [Indexed: 04/19/2024]
Abstract
PURPOSE To investigate the effects of mid-inspiratory respiration commands and other factors on transient interruption of contrast (TIC) incidence on CT pulmonary angiography. METHODS In this retrospective study, 824 patients (mean age, 66.1 ± 15.3 years; 342 males) who had undergone CT pulmonary angiography between January 2021 and February 2023 were included. Among them, 545 and 279 patients were scanned at end- and mid-inspiratory levels, respectively. By placing a circular region of interest, CT attenuation of the main pulmonary artery (CTMPA) was recorded. Associations between several factors, including patient age, body weight, sex, respiratory command vs. TIC and severe TIC incidence (defined as CTMPA < 200 and 150 HU, respectively), were assessed using logistic regression analyses with stepwise regression selection based on Akaike's information criterion. RESULTS Mid-inspiratory respiration command, in addition to patient age and lighter body weight, had negative association with the incidence of TIC. Only patient age, lighter body weight, female sex, and larger cardiothoracic ratio were negatively associated with severe TIC incidence. Mid-inspiratory respiration commands helped reduce TIC incidence among patients aged < 65 years (p = 0.039) and those with body weight ≥ 75 kg (p = 0.005) who were at high TIC risk. CONCLUSION Changing the respiratory command from end- to mid-inspiratory levels, as well as patient age and body weight, was significantly associated with TIC incidence.
Collapse
Affiliation(s)
- Koichiro Yasaka
- Department of Radiology, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan.
| | - Masumi Mizuki Takahashi
- Department of Radiology, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan
| | - Mariko Kurokawa
- Department of Radiology, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan
| | - Takatoshi Kubo
- Department of Radiology, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan
| | - Yusuke Watanabe
- Department of Radiology, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan
| | - Hiroyuki Saigusa
- Department of Radiology, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan
| | - Osamu Abe
- Department of Radiology, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan
| |
Collapse
|
3
|
Zhao J, Cheng Q, Liu C, Wang Q, Lv Y, Tang Z, Luo Y, Yang H. Optimal combination periprosthetic vasculature visualization and metal artifact reduction by spectral computed tomography using virtual monoenergetic images in total hip arthroplasty. Insights Imaging 2023; 14:181. [PMID: 37880460 PMCID: PMC10600072 DOI: 10.1186/s13244-023-01533-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2023] [Accepted: 09/29/2023] [Indexed: 10/27/2023] Open
Abstract
OBJECTIVES To investigate the optimal parameters of spectral CT for preferably visualizing the periprosthetic vasculature and metal artifact reduction (MAR) in total hip arthroplasty (THA). METHODS A total of 34 THA of 30 patients were retrospectively included. Image reconstructions included conventional image (CI), CI combined with MAR (CIMAR), and virtual monoenergetic images (VMI) combined with MAR (VMIMAR) at 50-120 keV. The attenuation and standard deviation of the vessel and artifact, and the width of artifact were measured. Qualitative scoring was evaluated including the vascular contour, the extent of artifact, and overall diagnostic evaluation. RESULTS The attenuation, noise of the vessel and artifact, and the width of artifact decreased as the energy level increased (p < 0.001). The downtrend was relatively flat at 80-120 keV, and the vascular attenuation dropped to 200 HU at 90 keV. The qualitative rating of vascular contour was significantly higher at CIMAR (3.47) and VMIMAR 60-80 keV (2.82-3.65) compared with CI (2.03) (p ≤ 0.029), and the highest score occurred at 70 and 80 keV (3.65 and 3.56). The score of the extent of artifact was higher at VMIMAR 80 keV than CIMAR (3.53 VS 3.12, p = 0.003). The score of the overall diagnostic evaluation was higher at VMIMAR 70 and 80 keV (3.32 and 3.53, respectively) than CIMAR (3.12) (p ≤ 0.035). CONCLUSION Eighty kiloelectron volts on VMIMAR, providing satisfactorily reduced metal artifacts and improved vascular visualization, can be an optimal recommended parameter of spectrum CT for the assessment of periprosthetic vasculature in THA patients. CRITICAL RELEVANCE STATEMENT The metal artifact is gradually reducing with increasing energy level; however, the vascular visualization is worsening. The vascular visualization is terrible above 100 keV, while the vessel is disturbed by artifacts below 70 keV. The best performance is found at 80 keV. KEY POINTS • VMIMAR can provide both reduced metal artifacts and improved vascular visualization. • Eighty kiloelectron volts on VMIMAR performs best in vascular visualization of total hip arthroplasty patients. • Energy spectrum CT is recommended for routine use in patients with total hip arthroplasty.
Collapse
Affiliation(s)
- Jie Zhao
- Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, 1 Youyi Road, Yuzhong District, Chongqing, 400016, China
| | - Qiang Cheng
- Department of Orthopedics, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Chuan Liu
- Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, 1 Youyi Road, Yuzhong District, Chongqing, 400016, China
| | - Qiqi Wang
- Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, 1 Youyi Road, Yuzhong District, Chongqing, 400016, China
| | - Yuchan Lv
- Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, 1 Youyi Road, Yuzhong District, Chongqing, 400016, China
| | - Ziyi Tang
- Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, 1 Youyi Road, Yuzhong District, Chongqing, 400016, China
| | - Yuxi Luo
- Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, 1 Youyi Road, Yuzhong District, Chongqing, 400016, China
| | - Haitao Yang
- Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, 1 Youyi Road, Yuzhong District, Chongqing, 400016, China.
| |
Collapse
|
4
|
Salyapongse AM, Rose SD, Pickhardt PJ, Lubner MG, Toia GV, Bujila R, Yin Z, Slavic S, Szczykutowicz TP. CT Number Accuracy and Association With Object Size: A Phantom Study Comparing Energy-Integrating Detector CT and Deep Silicon Photon-Counting Detector CT. AJR Am J Roentgenol 2023; 221:539-547. [PMID: 37255042 DOI: 10.2214/ajr.23.29463] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
BACKGROUND. Variable beam hardening based on patient size causes variation in CT numbers for energy-integrating detector (EID) CT. Photon-counting detector (PCD) CT more accurately determines effective beam energy, potentially improving CT number reliability. OBJECTIVE. The purpose of the present study was to compare EID CT and deep silicon PCD CT in terms of both the effect of changes in object size on CT number and the overall accuracy of CT numbers. METHODS. A phantom with polyethylene rings of varying sizes (mimicking patient sizes) as well as inserts of different materials was scanned on an EID CT scanner in single-energy (SE) mode (120-kV images) and in rapid-kilovoltage-switching dual-energy (DE) mode (70-keV images) and on a prototype deep silicon PCD CT scanner (70-keV images). ROIs were placed to measure the CT numbers of the materials. Slopes of CT number as a function of object size were computed. Materials' ideal CT number at 70 keV was computed using the National Institute of Standards and Technology XCOM Photon Cross Sections Database. The root mean square error (RMSE) between measured and ideal numbers was calculated across object sizes. RESULTS. Slope (expressed as Hounsfield units per centimeter) was significantly closer to zero (i.e., less variation in CT number as a function of size) for PCD CT than for SE EID CT for air (1.2 vs 2.4 HU/cm), water (-0.3 vs -1.0 HU/cm), iodine (-1.1 vs -4.5 HU/cm), and bone (-2.5 vs -10.1 HU/cm) and for PCD CT than for DE EID CT for air (1.2 vs 2.8 HU/cm), water (-0.3 vs -1.0 HU/cm), polystyrene (-0.2 vs -0.9 HU/cm), iodine (-1.1 vs -1.9 HU/cm), and bone (-2.5 vs -6.2 HU/cm) (p < .05). For all tested materials, PCD CT had the smallest RMSE, indicating CT numbers closest to ideal numbers; specifically, RMSE (expressed as Hounsfield units) for SE EID CT, DE EID CT, and PCD CT was 32, 44, and 17 HU for air; 7, 8, and 3 HU for water; 9, 10, and 4 HU for polystyrene; 31, 37, and 13 HU for iodine; and 69, 81, and 20 HU for bone, respectively. CONCLUSION. For numerous materials, deep silicon PCD CT, in comparison with SE EID CT and DE EID CT, showed lower CT number variability as a function of size and CT numbers closer to ideal numbers. CLINICAL IMPACT. Greater reliability of CT numbers for PCD CT is important given the dependence of diagnostic pathways on CT numbers.
Collapse
Affiliation(s)
- Aria M Salyapongse
- Department of Radiology, University of Wisconsin Madison, 1005 Wisconsin Institute for Medical Research, 1111 Highland Ave, Madison, WI 53705
| | - Sean D Rose
- Department of Diagnostic and Interventional Imaging, University of Texas Health Science Center at Houston, Houston, TX
| | - Perry J Pickhardt
- Department of Radiology, University of Wisconsin Madison, 1005 Wisconsin Institute for Medical Research, 1111 Highland Ave, Madison, WI 53705
- University of Wisconsin Carbone Cancer Center, University of Wisconsin Madison, Madison, WI
| | - Meghan G Lubner
- Department of Radiology, University of Wisconsin Madison, 1005 Wisconsin Institute for Medical Research, 1111 Highland Ave, Madison, WI 53705
| | - Giuseppe V Toia
- Department of Radiology, University of Wisconsin Madison, 1005 Wisconsin Institute for Medical Research, 1111 Highland Ave, Madison, WI 53705
- Department of Medical Physics, University of Wisconsin Madison, Madison, WI
| | | | | | | | - Timothy P Szczykutowicz
- Department of Radiology, University of Wisconsin Madison, 1005 Wisconsin Institute for Medical Research, 1111 Highland Ave, Madison, WI 53705
- Department of Medical Physics, University of Wisconsin Madison, Madison, WI
- Department of Biomedical Engineering, University of Wisconsin Madison, Madison, WI
| |
Collapse
|
5
|
Schade KA, Mergen V, Sartoretti T, Alkadhi H, Euler A. Pseudoenhancement in Cystic Renal Lesions - Impact of Virtual Monoenergetic Images of Photon-Counting Detector CT on Lesion Classification. Acad Radiol 2023; 30 Suppl 1:S305-S313. [PMID: 37150736 DOI: 10.1016/j.acra.2023.04.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2023] [Revised: 03/30/2023] [Accepted: 04/03/2023] [Indexed: 05/09/2023]
Abstract
RATIONALE AND OBJECTIVES To investigate the impact of virtual monoenergetic images (VMI) from photon-counting detector CT (PCD-CT) on the enhancement and classification of renal cysts. MATERIALS AND METHODS Adults with renal cysts (≥7 mm) who received a triphasic examination on a clinical PCD-CT (120 kVp; IQ level 68) between July 2021 and March 2022 were retrospectively identified. Only non-enhancing cysts (enhancement<10 HU between unenhanced and venous phase at 70 keV) were included. VMI from 40 to 190 keV with increments of 10 keV were reconstructed from the venous phase. Enhancement was measured to classify each lesion as non-enhancing (<10 HU), equivocally enhancing (10-19 HU), and definitely enhancing (≥20 HU). Classification changes as a function of VMI were assessed. Pearson correlation coefficient, the Kruskal-Wallis and the Chi-square test were used. RESULTS A total of 86 patients (mean age, 74 ± 9 years; 74 male) with 160 non-enhancing renal cysts (17.6 ± 10 mm) were included. CT attenuation of the cysts increased from higher to lower VMI levels with a mean attenuation of 4 ± 11 HU at 190 keV to 36 ± 17 HU at 40 keV. Mean attenuation of the renal parenchyma was 43 ± 4 HU at 190 keV and 414 ± 71 HU at 40 keV. No cyst exhibited enhancement from 70 keV to 190 keV. At 40, 50, and 60 keV, 35% (56/160), 29% (47/160) and 9% (15/160) of cysts showed equivocal and 46% (74/160), 10% (16/160), and 0% (0/160) definite enhancement, respectively. There was no significant influence of size (P=.13), cyst location (P=.9) and BMI (P=.19) on enhancement classification. CONCLUSION VMI has a relevant impact on enhancement and classification of renal cysts with misclassification in a large number of cases at energy levels below 70 keV.
Collapse
Affiliation(s)
- Katharina Alexandra Schade
- Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland (K.A.S., V.M., T.S., H.A., A.E.)
| | - Victor Mergen
- Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland (K.A.S., V.M., T.S., H.A., A.E.)
| | - Thomas Sartoretti
- Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland (K.A.S., V.M., T.S., H.A., A.E.)
| | - Hatem Alkadhi
- Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland (K.A.S., V.M., T.S., H.A., A.E.)
| | - André Euler
- Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland (K.A.S., V.M., T.S., H.A., A.E.); Institute of Radiology, Kantonsspital Baden, Baden, Switzerland (A.E.).
| |
Collapse
|
6
|
Zhao H, Liang P, Yong L, Cheng M, Zhang Y, Huang M, Gao J. Development and external validation of a radiomics model for assessment of HER2 positivity in men and women presenting with gastric cancer. Insights Imaging 2023; 14:20. [PMID: 36720737 PMCID: PMC9889592 DOI: 10.1186/s13244-022-01361-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2022] [Accepted: 12/19/2022] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND To develop and externally validate a conventional CT-based radiomics model for identifying HER2-positive status in gastric cancer (GC). METHODS 950 GC patients who underwent pretreatment CT were retrospectively enrolled and assigned into a training cohort (n = 388, conventional CT), an internal validation cohort (n = 325, conventional CT) and an external validation cohort (n = 237, dual-energy CT, DECT). Radiomics features were extracted from venous phase images to construct the "Radscore". On the basis of univariate and multivariate analyses, a conventional CT-based radiomics model was built in the training cohort, combining significant clinical-laboratory characteristics and Radscore. The model was assessed and validated regarding its diagnostic effectiveness and clinical practicability using AUC and decision curve analysis, respectively. RESULTS Location, clinical TNM staging, CEA, CA199, and Radscore were independent predictors of HER2 status (all p < 0.05). Integrating these five indicators, the proposed model exerted a favorable diagnostic performance with AUCs of 0.732 (95%CI 0.683-0.781), 0.703 (95%CI 0.624-0.783), and 0.711 (95%CI 0.625-0.798) observed for the training, internal validation, and external validation cohorts, respectively. Meanwhile, the model would offer more net benefits than the default simple schemes and its performance was not affected by the age, gender, location, immunohistochemistry results, and type of tissue for confirmation (all p > 0.05). CONCLUSIONS The conventional CT-based radiomics model had a good diagnostic performance of HER2 positivity in GC and the potential to generalize to DECT, which is beneficial to simplify clinical workflow and help clinicians initially identify potential candidates who might benefit from HER2-targeted therapy.
Collapse
Affiliation(s)
- Huiping Zhao
- grid.440288.20000 0004 1758 0451Department of CT, Shaanxi Provincial People’s Hospital, No. 256, Youyi West Road, Xi’an, 710068 Shaanxi Province China ,grid.412633.10000 0004 1799 0733Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No. 1, East Jianshe Road, Zhengzhou, 450052 Henan Province China ,Henan Key Laboratory of Image Diagnosis and Treatment for Digestive System Tumor & Henan International Joint Laboratory of Medical Imaging & Henan Engineering Laboratory of Tumor Imaging & Henan Key Laboratory of CT Imaging & Zhengzhou Key Laboratory of Medical Imaging Technology and Diagnosis, No. 1, East Jianshe Road, Zhengzhou, 450052 Henan Province China
| | - Pan Liang
- grid.412633.10000 0004 1799 0733Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No. 1, East Jianshe Road, Zhengzhou, 450052 Henan Province China ,Henan Key Laboratory of Image Diagnosis and Treatment for Digestive System Tumor & Henan International Joint Laboratory of Medical Imaging & Henan Engineering Laboratory of Tumor Imaging & Henan Key Laboratory of CT Imaging & Zhengzhou Key Laboratory of Medical Imaging Technology and Diagnosis, No. 1, East Jianshe Road, Zhengzhou, 450052 Henan Province China
| | - Liuliang Yong
- grid.412633.10000 0004 1799 0733Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No. 1, East Jianshe Road, Zhengzhou, 450052 Henan Province China ,Henan Key Laboratory of Image Diagnosis and Treatment for Digestive System Tumor & Henan International Joint Laboratory of Medical Imaging & Henan Engineering Laboratory of Tumor Imaging & Henan Key Laboratory of CT Imaging & Zhengzhou Key Laboratory of Medical Imaging Technology and Diagnosis, No. 1, East Jianshe Road, Zhengzhou, 450052 Henan Province China
| | - Ming Cheng
- Henan Key Laboratory of Image Diagnosis and Treatment for Digestive System Tumor & Henan International Joint Laboratory of Medical Imaging & Henan Engineering Laboratory of Tumor Imaging & Henan Key Laboratory of CT Imaging & Zhengzhou Key Laboratory of Medical Imaging Technology and Diagnosis, No. 1, East Jianshe Road, Zhengzhou, 450052 Henan Province China ,grid.412633.10000 0004 1799 0733Department of Medical Information, The First Affiliated Hospital of Zhengzhou University, No. 1, East Jianshe Road, Zhengzhou, 450052 Henan Province China
| | - Yan Zhang
- grid.440288.20000 0004 1758 0451Department of CT, Shaanxi Provincial People’s Hospital, No. 256, Youyi West Road, Xi’an, 710068 Shaanxi Province China
| | - Minggang Huang
- grid.440288.20000 0004 1758 0451Department of CT, Shaanxi Provincial People’s Hospital, No. 256, Youyi West Road, Xi’an, 710068 Shaanxi Province China
| | - Jianbo Gao
- grid.412633.10000 0004 1799 0733Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No. 1, East Jianshe Road, Zhengzhou, 450052 Henan Province China ,Henan Key Laboratory of Image Diagnosis and Treatment for Digestive System Tumor & Henan International Joint Laboratory of Medical Imaging & Henan Engineering Laboratory of Tumor Imaging & Henan Key Laboratory of CT Imaging & Zhengzhou Key Laboratory of Medical Imaging Technology and Diagnosis, No. 1, East Jianshe Road, Zhengzhou, 450052 Henan Province China
| |
Collapse
|
7
|
Han D, Yu Y, He T, Yu N, Dang S, Wu H, Ren J, Duan X. Effect of radiomics from different virtual monochromatic images in dual-energy spectral CT on the WHO/ISUP classification of clear cell renal cell carcinoma. Clin Radiol 2021; 76:627.e23-627.e29. [PMID: 33985770 DOI: 10.1016/j.crad.2021.02.033] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2020] [Accepted: 02/10/2021] [Indexed: 12/24/2022]
Abstract
AIM To investigate the effect of radiomics obtained from different virtual monochromatic images (VMIs) in dual-energy spectral computed tomography (CT) on the World Health Organization/International Association for Urological Pathology (WHO/ISUP) classification of clear cell renal cell carcinoma (ccRCC). MATERIALS AND METHODS A retrospective study of 99 ccRCC patients who underwent contrast-enhanced dual-energy CT was undertaken. ccRCC was confirmed at surgery or biopsy and graded according to the WHO/ISUP pathological grading criteria as low grade (n=68, grade I and II) or high grade (n=31, grade III and IV). Radiomics risk scores (RRSs) for differentiating high and low grades of ccRCC were constructed from 11 sets of VMI in (40-140 keV, 10 keV interval) the cortical phase. Receiver operating characteristic (ROC) curves were drawn and the area under the curves (AUCs) was calculated to evaluate the discriminatory power of RRS for each VMI. The Hosmer-Lemeshow test was used to evaluate the goodness-of-fit of each model and the decision curve was used to analyse its net benefit to patients. RESULTS The AUC values for distinguishing low-from high-grade ccRCC with RRS of 40-140 keV VMIs were all >0.920. The Hosmer-Lemeshow test showed that the p-values of RRS of VMIs were >0.05, suggesting good fits. In the decision curve analysis, RRS from the 40-140 keV VMIs had similar decision curves and provided better net benefits than considering all patients either as high-grade or low-grade. CONCLUSIONS The RRS obtained from multiple VMIs in dual-energy spectral CT have high diagnostic efficiencies for distinguishing between low- and high-grade ccRCC with no significant differences between different VMIs.
Collapse
Affiliation(s)
- D Han
- Department of Medical Image, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China
| | - Y Yu
- Department of Radiology, Affiliated Hospital of Shaanxi University of Chinese Medicine, Xianyang, Shaanxi, China
| | - T He
- Department of Radiology, Affiliated Hospital of Shaanxi University of Chinese Medicine, Xianyang, Shaanxi, China
| | - N Yu
- Department of Radiology, Affiliated Hospital of Shaanxi University of Chinese Medicine, Xianyang, Shaanxi, China
| | - S Dang
- Department of Medical Image, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China
| | - H Wu
- Pathology Department, Affiliated Hospital of Shaanxi University of Chinese Medicine, Xianyang, Shaanxi, China
| | - J Ren
- GE Healthcare China, Beijing, China
| | - X Duan
- Department of Medical Image, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China.
| |
Collapse
|
8
|
Yuan Y, Lang N, Yuan H. Rapid-kilovoltage-switching dual-energy computed tomography (CT) for differentiating spinal osteolytic metastases from spinal infections. Quant Imaging Med Surg 2021; 11:620-627. [PMID: 33532262 DOI: 10.21037/qims-20-334] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Background Rapid-kilovoltage-switching dual-energy computed tomography (RDECT) is a non-invasive, alternative technique for quantitative diagnosis. This study aimed to investigate the value of RDECT for differentiating spinal osteolytic metastases (SOM) from spinal infections (SIs). Methods RDECT was performed on 29 patients with SOM and 18 patients with SIs. Both iodine-based and water-based material decomposition images were generated from the spectral CT scan. The iodine/water densities of lesions on iodine/water material-decomposition images and the CT attenuation values on traditional CT images were measured three times at different image levels, and the averages were calculated. The lesion-to-muscle ratio (LMR) and lesion-to-artery ratio (LAR) for iodine density measurements were calculated. All parameters were compared between the two groups using the two-tailed Student's t-test. A P value <0.05 was considered statistically significant. The sensitivity and specificity for differentiating SOM from SIs were determined using receiver operating characteristic curves (ROC). Results Iodine density, LMR, and LAR during the arterial phase (AP) and venous phase (VP) were all significantly higher for SOM than for SIs (all P<0.05). The water densities and traditional CT attenuation values during the AP and VP were not significantly different between the two groups. For ROC analysis, LAR during the VP (LARVP) showed the best diagnostic performance, with an area under the ROC curve (AUC) value of 0.862. When the LARVP was 0.54, the sensitivity was 82.80% and the specificity was 77.80% for differentiating SOM from SIs. Conclusions RDECT can provide additional information that may be useful for differentiating atypical SOM from SIs.
Collapse
Affiliation(s)
- Yuan Yuan
- Department of Radiology, Peking University Third Hospital, Beijing, China
| | - Ning Lang
- Department of Radiology, Peking University Third Hospital, Beijing, China
| | - Huishu Yuan
- Department of Radiology, Peking University Third Hospital, Beijing, China
| |
Collapse
|
9
|
Masuda S, Sugisawa K, Minamishima K, Yamazaki A, Jinzaki M. Assessment of the image quality of virtual monochromatic spectral computed tomography images: a phantom study considering object contrast, radiation dose, and frequency characteristics. Radiol Phys Technol 2021; 14:41-49. [PMID: 33400064 DOI: 10.1007/s12194-020-00597-w] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2020] [Revised: 11/18/2020] [Accepted: 11/20/2020] [Indexed: 11/24/2022]
Abstract
Fast kilovoltage (kVp)-switching technology cannot obtain conventional 120 kVp images; thus, 70 keV virtual monochromatic spectral computed tomography (CT) images (VMSI) are generally used. The contrast-to-noise ratio (CNR) is used to evaluate the image quality of VMSI; however, CNR does not include frequency characteristics. The present study aimed to investigate the evaluation methods of VMSI considering frequency characteristics by comparing the image quality of 70 keV VMSI with that of conventional 120 kVp images. The evaluated object contrasts were 70 and 300 Hounsfield units (HU). Scans used two radiation dose levels: low (LD) and standard (SD). The volume CT dose index of LD and SD was 4.8- and 12 mGy, respectively. Images were reconstructed by filtered back projection, evaluating CNR, noise power spectrum (NPS), task transfer function (TTF), and system performance (SP) function calculated as TTF2/ NPS. The total NPS values (spatial frequency range: 0.2 ~ 0.4 mm-1) of 70 keV VMSI were higher than those of 120 kVp images. The spatial frequency TTF values that reached 10% (f10%) of the 70 keV VMSI changed based on object contrast. For the low-contrast condition, a lower f10% was observed with 70 keV VMSI. The CNR of 70 keV VMSI was comparable to that of 120 kVp images in low- and high-contrast conditions. However, for 70 keV VMSI, SP of low-contrast was low, and SP of high-contrast was high, compared with those of 120 kVp images. This study suggested that only CNR was not sufficient to evaluate the image quality of VMSI; thus, evaluation methods considering frequency characteristics should be used.
Collapse
Affiliation(s)
- Shota Masuda
- Office of Radiological Technology, Keio University Hospital, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan.
| | - Koichi Sugisawa
- Office of Radiological Technology, Keio University Hospital, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan
| | - Kazuya Minamishima
- Office of Radiological Technology, Keio University Hospital, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan
| | - Akihisa Yamazaki
- Office of Radiological Technology, Keio University Hospital, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan
| | - Masahiro Jinzaki
- Department of Radiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan
| |
Collapse
|
10
|
Torensma B, Kooiman L, Liem R, Monpellier VM, Swank DJ, Tseng L. Internal Herniation Incidence After RYGB and the Predictive Ability of a CT Scan as a Diagnostic Tool. Obes Surg 2021; 31:127-132. [PMID: 32748202 PMCID: PMC7808966 DOI: 10.1007/s11695-020-04892-8] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2020] [Revised: 07/24/2020] [Accepted: 07/28/2020] [Indexed: 12/14/2022]
Abstract
PURPOSE The clinical diagnosis of an internal herniation (IH) after a Roux-en-Y Gastric Bypass (RYGB) remains difficult; therefore, performing a CT scan is usually part of the diagnostic process. The goal of this study was to assess the incidence of IH in patients with open and closed MD (mesenteric defect) and to study if the ability to diagnose an IH with a CT scan is different between these groups. MATERIALS AND METHODS IH was defined as a visible intestine through the mesenteric defect underneath the jejunojejunostomy and/or in the Petersen's space. CT scan outcomes were compared with the clinical diagnosis of an IH. Until 31 June 2013, standard care was to leave mesenteric defects (MDs) open; after this date, they were always closed. RESULTS The incidence of IH in the primarily non-closed group was 3.9%, and in the primarily closed group, this was 1.3% (p = 0.001). In group A (non-closed MD and CT), the sensitivity of the CT scan was 80%, and specificity was 0%. In group C (closed MD and CT), the sensitivity was 64.7%, and specificity was 89.5%. In group B (non-closed, no CT), an IH was visible in 58.7% of the cases and not in 41.3%. In group D (only a re-laparoscopy), an IH was visible in 34.3% of the cases and not in 65.7%. CONCLUSIONS Using the CT scan in suspected IH is not useful in if the MDs were not closed. If the MDs were closed, then a CT scan is predictive for the diagnosis IH.
Collapse
Affiliation(s)
- Bart Torensma
- Department of Anaesthesiology, Leiden University Medical Center, Leiden, The Netherlands.
- Department of Surgery, Dutch Obesity Clinic West & LUMC, The Hague, The Netherlands.
| | - Laurens Kooiman
- Department of Surgery, Dutch Obesity Clinic West & LUMC, The Hague, The Netherlands
| | - Ronald Liem
- Department of Surgery, Dutch Obesity Clinic West & LUMC, The Hague, The Netherlands
| | - Valerie M Monpellier
- Department of Surgery, Dutch Obesity Clinic West & LUMC, The Hague, The Netherlands
| | - Dingeman J Swank
- Department of Surgery, Dutch Obesity Clinic West & LUMC, The Hague, The Netherlands
| | - Larissa Tseng
- Department of Surgery, Dutch Obesity Clinic West & LUMC, The Hague, The Netherlands
| |
Collapse
|
11
|
Donders JCE, Wellenberg RHH, Streekstra GJ, Maas M, Kloen P. Improved diagnostic confidence in evaluating bone non-union using virtual monochromatic dual-energy CT. Eur J Radiol 2020; 132:109159. [PMID: 33091864 DOI: 10.1016/j.ejrad.2020.109159] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2020] [Revised: 04/28/2020] [Accepted: 06/29/2020] [Indexed: 10/23/2022]
Abstract
PURPOSE The aim of this study was to determine whether virtual monochromatic dual-energy CT imaging improves the evaluation of suspected non-union of the appendicular skeleton treated with titanium or stainless steel intramedullary nails and plates. METHOD Forty-one patients with a clinical suspected non-union with hardware in place were included and scanned on a dual-source CT-scanner using 100/Sn150kVp. Images including titanium hardware were extracted at 130 keV. Images including stainless steel hardware were extracted at 150 keV. Monochromatic 70 keV images served as reference. Non-union confirmed during revision surgery was used as gold standard. A musculoskeletal radiologist and orthopedic trauma surgeon evaluated images on image quality, degree and location of consolidation, non-union type and diagnostic confidence. RESULTS Likert scores with respect to image quality improved from 0.88 to 1.83 (p < 0.001) in high (130 and 150) keV images. High keV images reduced the number of false negative non-unions based on consolidation grade with 5% (p = 0.283). Agreement between observers regarding location of consolidation and non-union type did not improve in 130 and 150 keV images. Diagnostic confidence improved from 1.43 to 2.37 in high keV images compared to 70 keV images (p < 0.001). Overall diagnostic confidence was higher in intramedullary nails than plates (p < 0.05). CONCLUSIONS Use of virtual monochromatic 130 and 150 keV dual-energy CT compared to 70 keV images improves the evaluation of suspected non-union of the appendicular skeleton treated with titanium or stainless steel intramedullary nails and plates.
Collapse
Affiliation(s)
- J C E Donders
- Department of Orthopedic Surgery, Amsterdam UMC, Location AMC, Amsterdam, the Netherlands.
| | - R H H Wellenberg
- Department of Radiology and Nuclear Medicine, Amsterdam UMC, Location AMC, Amsterdam Movement Sciences, Amsterdam, the Netherlands; Department of Radiology, Isala, Zwolle, the Netherlands.
| | - G J Streekstra
- Department of Biomedical Engineering and Physics, Amsterdam UMC, Location AMC, Amsterdam, the Netherlands.
| | - M Maas
- Department of Radiology and Nuclear Medicine, Amsterdam UMC, Location AMC, Amsterdam Movement Sciences, Amsterdam, the Netherlands.
| | - P Kloen
- Department of Orthopedic Surgery, Amsterdam UMC, Location AMC, Amsterdam, the Netherlands.
| |
Collapse
|
12
|
Conzelmann J, Schwarz FB, Hamm B, Scheel M, Jahnke P. Development of a method to create uniform phantoms for task-based assessment of CT image quality. J Appl Clin Med Phys 2020; 21:201-208. [PMID: 32721106 PMCID: PMC7497917 DOI: 10.1002/acm2.12974] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2019] [Revised: 06/13/2020] [Accepted: 06/18/2020] [Indexed: 12/22/2022] Open
Abstract
Purpose To develop a customized method to produce uniform phantoms for task‐based assessment of CT image quality. Methods Contrasts between polymethyl methacrylate (PMMA) and fructose solutions of different concentrations (240, 250, 260, 280, 290, 300, 310, 320, 330, and 340 mg/mL) were calculated. A phantom was produced by laser cutting PMMA slabs to the shape of a patient’s neck. An opening of 10 mm diameter was cut into the left parapharyngeal space. An angioplasty balloon was inserted and filled with the fructose solutions to simulate low‐contrast lesions. The phantom was scanned with six tube currents. Images were reconstructed with filtered back projection (FBP) and adaptive iterative dose reduction 3D (AIDR 3D). Calculated and measured contrasts were compared. The phantom was evaluated in a detectability experiment using images with 4 and 20 HU lesion contrast. Results Low‐contrast lesions of 4, 9, 11, 13, 18, 20, 24, 30, 35, and 37 HU contrast were simulated. Calculated and measured contrasts correlated excellently (r = 0.998; 95% confidence interval: 0.991 to 1). The mean ± SD difference was 0.41 ± 2.32 HU (P < 0.0001). Detection accuracy and reader confidence were 62.9 ± 18.2% and 1.58 ± 0.68 for 4 HU lesion contrast and 99.6 ± 1.3% and 4.27 ± 0.92 for 20 HU lesion contrast (P < 0.0001), confirming that the method produced lesions at the threshold of detectability. Conclusion A cost‐effective and flexible approach was developed to create uniform phantoms with low‐contrast signals. The method should facilitate access to customized phantoms for task‐based image quality assessment.
Collapse
Affiliation(s)
- Juliane Conzelmann
- Department of Radiology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, Berlin Institute of Health, Berlin, Germany
| | - Felix Benjamin Schwarz
- Department of Radiology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, Berlin Institute of Health, Berlin, Germany
| | - Bernd Hamm
- Department of Radiology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, Berlin Institute of Health, Berlin, Germany
| | - Michael Scheel
- Department of Neuroradiology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, Berlin Institute of Health, Berlin, Germany
| | - Paul Jahnke
- Department of Radiology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, Berlin Institute of Health, Berlin, Germany
| |
Collapse
|
13
|
Krishna S, Leckie A, Kielar A, Hartman R, Khandelwal A. Imaging of Renal Cancer. Semin Ultrasound CT MR 2020; 41:152-169. [DOI: 10.1053/j.sult.2019.12.004] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
14
|
Wang P, Xiao Z, Tang Z, Wang J. Dual-energy CT in the differentiation of stage T1 nasopharyngeal carcinoma and lymphoid hyperplasia. Eur J Radiol 2020; 124:108824. [PMID: 31954331 DOI: 10.1016/j.ejrad.2020.108824] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2019] [Revised: 10/03/2019] [Accepted: 12/30/2019] [Indexed: 01/05/2023]
Abstract
PURPOSE To explore the value of dual-energy CT for the differentiation between stage T1 nasopharyngeal carcinoma (NPCT1) and lymphoid hyperplasia (LH). METHOD Patients with histopathological proven nasopharyngeal lesions (stage T1 NPCs, n = 30; LHs, n = 47) who underwent dual-energy CT were enrolled in this retrospective study. Quantitative parameters derived from dual-energy CT were measured. Statistical analyses were performed using the independent sample t-test, Wilcoxon rank sum test, and receiver operating characteristic curve (ROC) analysis. RESULTS There was significantly higher iodine concentration (IC), normalized iodine concentration (NIC, to internal jugular vein) in NPCT1 compared with LH (p < 0.001). The effective atomic number (Zeff) was significantly higher in NPCT1 than that in LH (p < 0.001). The virtual monochromatic images (VMIs) at 50 keV-110 keV (20 keV-interval) of NPCT1 were all significantly higher than those of LH (all p <0.001). The slope (k) value of spectral attenuation curve was also significantly higher in NPCT1 than LH (p < 0.001). There was no significant difference in virtual noncontrast (VNC) and 130 keV-190 keV (20 keV-interval) between the NPCT1 and LH. For discriminating NPCT1 from LH, the area under curve (AUC) using 70 keV was the highest in all single parameter (AUC, 0.92; sensitivity, 80.00 %; specificity, 91.49 %). Combined multiple parameters (IC, NIC, Zeff, 50 keV, 70 keV, 90 keV, slope (k)) by performing multivariate logistic regression model significantly improve the diagnostic capability in differentiating these two entities, with AUC, sensitivity, and specificity values of 0.99, 93.33 %, 97.87 %, respectively. CONCLUSIONS Dual-energy CT can be helpful for the differentiation between NPCT1 and LH lesions.
Collapse
Affiliation(s)
- Peng Wang
- Department of Radiology, Eye & ENT Hospital of Shanghai Medical School, Fudan University, Shanghai, PR China
| | - Zebin Xiao
- Department of Radiology, Eye & ENT Hospital of Shanghai Medical School, Fudan University, Shanghai, PR China
| | - Zuohua Tang
- Department of Radiology, Eye & ENT Hospital of Shanghai Medical School, Fudan University, Shanghai, PR China.
| | - Jie Wang
- Department of Otolaryngology, Eye & ENT Hospital of Shanghai Medical School, Fudan University, Shanghai, PR China
| |
Collapse
|
15
|
Diagnostic Accuracy of Attenuation Difference and Iodine Concentration Thresholds at Rapid-Kilovoltage-Switching Dual-Energy CT for Detection of Enhancement in Renal Masses. AJR Am J Roentgenol 2019; 213:619-625. [PMID: 31120787 DOI: 10.2214/ajr.18.20990] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
OBJECTIVE. The objective of our study was to evaluate iodine concentration and attenuation change in Hounsfield unit (ΔHU) thresholds to diagnose enhancement in renal masses at rapid-kilovoltage-switching dual-energy CT (DECT). MATERIALS AND METHODS. We evaluated 30 consecutive histologically confirmed solid renal masses (including nine papillary renal cell carcinomas [RCCs]) and 27 benign cysts (17 simple and 10 hemorrhagic or proteinaceous cysts) with DECT December 2016 and May 2018. A blinded radiologist measured iodine concentration (in milligrams per milliliter) and ΔHU (attenuation on enhanced CT - attenuation on unenhanced CT) using 70-keV corticomedullary (CM) phase virtual monochromatic and 120-kVp nephrographic (NG) phase images. The accuracies of previously described enhancement thresholds were compared by ROC curve analysis. RESULTS. An iodine concentration of ≥ 2.0 mg/mL and an iodine concentration of ≥ 1.2 mg/mL achieved sensitivity, specificity, and the area under the ROC curve (AUC) of 73.3%, 100.0%, and 0.87 and 86.7%, 100.0%, and 0.93, respectively. On 70-keV CM phase images, ΔHU ≥ 20 HU and ΔHU ≥ 15 HU yielded sensitivity, specificity, and AUC of 80.0%, 100.0%, and 0.90 and 90.0%, 100.0%, and 0.95, respectively. The numbers of incorrectly classified papillary RCCs were as follows: iodine concentration of ≥ 2.0 mg/mL, 77.8% (7/9; range, 0.7-1.6 mg/mL); iodine concentration of ≥ 1.2 mg/mL, 44.4% (4/9; range, 0.7-0.9 mg/mL); ΔHU ≥ 20 HU on 70-keV CM phase images, 66.7% (6/9; range, 4-17 HU); and ΔHU ≥ 15 HU on 70-keV DECT images, 33.3% (3/9; 4-12 HU). No cyst pseudoenhancement occurred on DECT. For 120-kVp NG phase DECT, ΔHU ≥ 20 HU and ΔHU ≥ 15 HU yielded sensitivity, specificity, and AUC of 93.3%, 96.3%, and 0.95 and 100.0%, 88.9%, and 0.94, respectively. With ΔHU ≥ 20 HU, 22.2% (2/9) (range, 15-18 HU) of papillary RCCs were misclassified and there was one pseudoenhancing cyst. With ΔHU ≥ 15 HU, no papillary RCCs were misclassified but 11.1% (3/27) of cysts showed pseudoenhancement. Only an iodine concentration of ≥ 2.0 mg/mL showed significantly lower accuracy than other measures (p = 0.031-0.045). CONCLUSION. DECT applied in the CM phase performed best using an iodine concentration of ≥ 1.2 mg/mL or a 70-keV ΔHU ≥ 15 HU; these parameters improved sensitivity for the detection of enhancement in renal masses without instances of cyst pseudoenhancement.
Collapse
|
16
|
Recommendations for the Management of the Incidental Renal Mass in Adults: Endorsement and Adaptation of the 2017 ACR Incidental Findings Committee White Paper by the Canadian Association of Radiologists Incidental Findings Working Group. Can Assoc Radiol J 2019; 70:125-133. [DOI: 10.1016/j.carj.2019.03.002] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2019] [Revised: 02/26/2019] [Accepted: 03/02/2019] [Indexed: 12/14/2022] Open
|
17
|
Diagnostic Accuracy of Dual-Energy CT for Evaluation of Renal Masses: Systematic Review and Meta-Analysis. AJR Am J Roentgenol 2019; 212:W100-W105. [DOI: 10.2214/ajr.18.20527] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
|