1
|
Lennartz S, Cao J, Pisuchpen N, Srinivas-Rao S, Locascio JJ, Parakh A, Hahn PF, Mileto A, Sahani D, Kambadakone A. Intra-patient variability of iodine quantification across different dual-energy CT platforms: assessment of normalization techniques. Eur Radiol 2024; 34:5131-5141. [PMID: 38189979 DOI: 10.1007/s00330-023-10560-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2023] [Revised: 11/18/2023] [Accepted: 12/08/2023] [Indexed: 01/09/2024]
Abstract
OBJECTIVES To investigate intra-patient variability of iodine concentration (IC) between three different dual-energy CT (DECT) platforms and to test different normalization approaches. METHODS Forty-four patients who underwent portal venous phase abdominal DECT on a dual-source (dsDECT), a rapid kVp switching (rsDECT), and a dual-layer detector platform (dlDECT) during cancer follow-up were retrospectively included. IC in the liver, pancreas, and kidneys and different normalized ICs (NICPV:portal vein; NICAA:abdominal aorta; NICALL:overall iodine load) were compared between the three DECT scanners for each patient. A longitudinal mixed effects analysis was conducted to elucidate the effect of the scanner type, scan order, inter-scan time, and contrast media amount on normalized iodine concentration. RESULTS Variability of IC was highest in the liver (dsDECT vs. dlDECT 28.96 (14.28-46.87) %, dsDECT vs. rsDECT 29.08 (16.59-62.55) %, rsDECT vs. dlDECT 22.85 (7.52-33.49) %), and lowest in the kidneys (dsDECT vs. dlDECT 15.76 (7.03-26.1) %, dsDECT vs. rsDECT 15.67 (8.86-25.56) %, rsDECT vs. dlDECT 10.92 (4.92-22.79) %). NICALL yielded the best reduction of IC variability throughout all tissues and inter-scanner comparisons, yet did not reduce the variability between dsDECT vs. dlDECT and rsDECT, respectively, in the liver. The scanner type remained a significant determinant for NICALL in the pancreas and the liver (F-values, 12.26 and 23.78; both, p < 0.0001). CONCLUSIONS We found tissue-specific intra-patient variability of IC across different DECT scanner types. Normalization mitigated variability by reducing physiological fluctuations in iodine distribution. After normalization, the scanner type still had a significant effect on iodine variability in the pancreas and liver. CLINICAL RELEVANCE STATEMENT Differences in iodine quantification between dual-energy CT scanners can partly be mitigated by normalization, yet remain relevant for specific tissues and inter-scanner comparisons, which should be taken into account at clinical routine imaging. KEY POINTS • Iodine concentration showed the least variability between scanner types in the kidneys (range 10.92-15.76%) and highest variability in the liver (range 22.85-29.08%). • Normalizing tissue-specific iodine concentrations against the overall iodine load yielded the greatest reduction of variability between scanner types for 2/3 inter-scanner comparisons in the liver and for all (3/3) inter-scanner comparisons in the kidneys and pancreas, respectively. • However, even after normalization, the dual-energy CT scanner type was found to be the factor significantly influencing variability of iodine concentration in the liver and pancreas.
Collapse
Affiliation(s)
- Simon Lennartz
- Department of Radiology, Abdominal Radiology Division, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, White 270, Boston, MA, 02114-2696, USA
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener Straße 62, 50937, Cologne, Germany
| | - Jinjin Cao
- Department of Radiology, Abdominal Radiology Division, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, White 270, Boston, MA, 02114-2696, USA
| | - Nisanard Pisuchpen
- Department of Radiology, Abdominal Radiology Division, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, White 270, Boston, MA, 02114-2696, USA
- Department of Radiology, King Chulalongkorn Memorial Hospital, Thai Red Cross Society, Faculty of Medicine, Chulalongkorn University, Bangkok, 10330, Thailand
| | - Shravya Srinivas-Rao
- Department of Radiology, Abdominal Radiology Division, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, White 270, Boston, MA, 02114-2696, USA
| | - Joseph J Locascio
- Harvard Catalyst Biostatistical Unit, Harvard Medical School/Massachusetts General Hospital, Boston, MA, USA
| | - Anushri Parakh
- Department of Radiology, Abdominal Radiology Division, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, White 270, Boston, MA, 02114-2696, USA
| | - Peter F Hahn
- Department of Radiology, Abdominal Radiology Division, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, White 270, Boston, MA, 02114-2696, USA
| | - Achille Mileto
- Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN, 55905, USA
| | - Dushyant Sahani
- Department of Radiology, University of Washington, UWMC Radiology RR218, 1959 NE Pacific St, Seattle, WA, 98195, USA
| | - Avinash Kambadakone
- Department of Radiology, Abdominal Radiology Division, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, White 270, Boston, MA, 02114-2696, USA.
| |
Collapse
|
2
|
Albano D, Di Luca F, D'Angelo T, Booz C, Midiri F, Gitto S, Fusco S, Serpi F, Messina C, Sconfienza LM. Dual-energy CT in musculoskeletal imaging: technical considerations and clinical applications. LA RADIOLOGIA MEDICA 2024; 129:1038-1047. [PMID: 38743319 PMCID: PMC11252181 DOI: 10.1007/s11547-024-01827-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/20/2024] [Accepted: 05/06/2024] [Indexed: 05/16/2024]
Abstract
Dual-energy CT stands out as a robust and innovative imaging modality, which has shown impressive advancements and increasing applications in musculoskeletal imaging. It allows to obtain detailed images with novel insights that were once the exclusive prerogative of magnetic resonance imaging. Attenuation data obtained by using different energy spectra enable to provide unique information about tissue characterization in addition to the well-established strengths of CT in the evaluation of bony structures. To understand clearly the potential of this imaging modality, radiologists must be aware of the technical complexity of this imaging tool, the different ways to acquire images and the several algorithms that can be applied in daily clinical practice and for research. Concerning musculoskeletal imaging, dual-energy CT has gained more and more space for evaluating crystal arthropathy, bone marrow edema, and soft tissue structures, including tendons and ligaments. This article aims to analyze and discuss the role of dual-energy CT in musculoskeletal imaging, exploring technical aspects, applications and clinical implications and possible perspectives of this technique.
Collapse
Affiliation(s)
- Domenico Albano
- IRCCS Istituto Ortopedico Galeazzi, Milan, Italy.
- Dipartimento di Scienze Biomediche, Chirurgiche ed Odontoiatriche, Università degli Studi di Milano, Milan, Italy.
| | - Filippo Di Luca
- Scuola di Specializzazione in Radiodiagnostica, Università degli Studi di Milano, Milan, Italy
| | - Tommaso D'Angelo
- Diagnostic and Interventional Radiology Unit, BIOMORF Department, University Hospital Messina, Messina, Italy
- Department of Radiology and Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands
| | - Christian Booz
- Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt am Main, Germany
| | | | - Salvatore Gitto
- IRCCS Istituto Ortopedico Galeazzi, Milan, Italy
- Dipartimento di Scienze Biomediche per la Salute, Università degli Studi di Milano, Milan, Italy
| | - Stefano Fusco
- Dipartimento di Scienze Biomediche per la Salute, Università degli Studi di Milano, Milan, Italy
| | - Francesca Serpi
- IRCCS Istituto Ortopedico Galeazzi, Milan, Italy
- Dipartimento di Scienze Biomediche per la Salute, Università degli Studi di Milano, Milan, Italy
| | - Carmelo Messina
- IRCCS Istituto Ortopedico Galeazzi, Milan, Italy
- Dipartimento di Scienze Biomediche per la Salute, Università degli Studi di Milano, Milan, Italy
| | - Luca Maria Sconfienza
- IRCCS Istituto Ortopedico Galeazzi, Milan, Italy
- Dipartimento di Scienze Biomediche per la Salute, Università degli Studi di Milano, Milan, Italy
| |
Collapse
|
3
|
Yel I, Bucolo GM, Mahmoudi S, Koch V, Gökduman A, D Angelo T, Grünewald LD, Dimitrova M, Eichler K, Vogl TJ, Booz C. Dual-Energy CT Iodine Uptake of Head and Neck: Definition of Reference Values in a Big Data Cohort. Diagnostics (Basel) 2024; 14:496. [PMID: 38472968 DOI: 10.3390/diagnostics14050496] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2024] [Revised: 02/22/2024] [Accepted: 02/23/2024] [Indexed: 03/14/2024] Open
Abstract
BACKGROUND Despite a considerable amount of literature on dual-energy CT (DECT) iodine uptake of the head and neck, the physiologic iodine uptake of this region has not been defined yet. This study aims to establish reference values for the iodine uptake of healthy organs to facilitate clinical application. METHODS Consecutive venous DECT scans of the head and neck were reviewed, and unremarkable exams were included (n = 617). A total of 35 region of interest measurements were performed in 16 anatomical regions. Iodine uptake was compared among different organs/tissues and subgroup analysis was performed (male (n = 403) vs. female (n = 214); young (n = 207) vs. middle-aged (n = 206) vs. old (n = 204); and normal weight (n = 314) vs. overweight (n = 196) vs. obese (n = 107)). RESULTS Overall mean iodine uptake values ranged between 0.5 and 9.4 mg/mL. Women showed higher iodine concentrations in the cervical vessels and higher uptake for the parotid gland, masseter muscle, submandibular glands, sublingual glands, palatine tonsils, tongue body, thyroid gland, and the sternocleidomastoid muscle than men (p ≤ 0.04). With increasing age, intravascular iodine concentrations increased as well as iodine uptake for cerebellum and thyroid gland, while values for the tongue and palatine tonsils were lower compared to younger subjects (p ≤ 0.03). Iodine concentrations for parotid glands and sternocleidomastoid muscles decreased with a higher BMI (p ≤ 0.004), while normal-weighted patients showed higher iodine values inside the jugular veins, other cervical glands, and tonsils versus patients with a higher BMI (p ≤ 0.04). CONCLUSION physiologic iodine uptake values of cervical organs and tissues show gender-, age-, and BMI-related differences, which should be considered in the clinical routine of head and neck DECT.
Collapse
Affiliation(s)
- Ibrahim Yel
- Goethe University Frankfurt, University Hospital Frankfurt, Clinic for Radiology and Nuclear Medicine, 60590 Frankfurt, Germany
| | - Giuseppe Mauro Bucolo
- Department of Biomedical Sciences and Morphological and Functional Imaging, University of Messina, 98122 Messina, Italy
| | - Scherwin Mahmoudi
- Goethe University Frankfurt, University Hospital Frankfurt, Clinic for Radiology and Nuclear Medicine, 60590 Frankfurt, Germany
| | - Vitali Koch
- Goethe University Frankfurt, University Hospital Frankfurt, Clinic for Radiology and Nuclear Medicine, 60590 Frankfurt, Germany
| | - Aynur Gökduman
- Goethe University Frankfurt, University Hospital Frankfurt, Clinic for Radiology and Nuclear Medicine, 60590 Frankfurt, Germany
| | - Tommaso D Angelo
- Department of Biomedical Sciences and Morphological and Functional Imaging, University of Messina, 98122 Messina, Italy
| | - Leon David Grünewald
- Goethe University Frankfurt, University Hospital Frankfurt, Clinic for Radiology and Nuclear Medicine, 60590 Frankfurt, Germany
| | - Mirela Dimitrova
- Goethe University Frankfurt, University Hospital Frankfurt, Clinic for Radiology and Nuclear Medicine, 60590 Frankfurt, Germany
| | - Katrin Eichler
- Goethe University Frankfurt, University Hospital Frankfurt, Clinic for Radiology and Nuclear Medicine, 60590 Frankfurt, Germany
| | - Thomas J Vogl
- Goethe University Frankfurt, University Hospital Frankfurt, Clinic for Radiology and Nuclear Medicine, 60590 Frankfurt, Germany
| | - Christian Booz
- Goethe University Frankfurt, University Hospital Frankfurt, Clinic for Radiology and Nuclear Medicine, 60590 Frankfurt, Germany
| |
Collapse
|
4
|
Zhao X, Wang X, Wang S, Chen L, Sun S. Absolute and relative iodine concentrations in the spot sign and haematoma for prediction of haematoma expansion in spontaneous intracerebral haemorrhage. Clin Radiol 2023; 78:e950-e957. [PMID: 37690974 DOI: 10.1016/j.crad.2023.08.014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2023] [Revised: 08/15/2023] [Accepted: 08/16/2023] [Indexed: 09/12/2023]
Abstract
AIM To explore the predictive value of absolute and relative iodine concentrations in the spot sign (SS) and haematoma on gemstone spectral imaging (GSI) for haematoma expansion (HE). MATERIALS AND METHODS Patients with spontaneous intracerebral haemorrhage (ICH) who underwent computed tomography (CT) angiography using GSI were divided into an SS-positive group and an SS-negative group. In the SS-positive group, absolute and relative iodine concentrations in the SS (aICIS and rICIS, respectively) were measured. In the SS-negative group, absolute and relative iodine concentrations in haematoma (aICIH and rICIH, respectively) were measured. The area under the receiver operating characteristic curve (AUC-ROC) was used to investigate the HE predictive performance of aICIS, rICIS, and their combination in the SS-positive group, as well as the HE predictive performance of aICIH, rICIH, and their combination in the SS-negative group. The risk variables for HE in the two groups were investigated separately using logistic regression. RESULTS A total of 123 spontaneous ICH patients were enrolled. In the SS-positive group, the AUC of aICIS, rICIS, and their combination for predicting HE were 0.853, 0.893, and 0.922, respectively. rICIS was demonstrated to be a standalone predictor of HE via logistic regression. In the SS-negative group, aICIH, rICIH, and their combination had AUC-ROC values of 0.552, 0.783, and 0.851, respectively, to predict HE. According to multivariate analysis, rICIH was a reliable predictor of HE. CONCLUSION Absolute and relative iodine concentrations in the SS and haematoma can predict HE.
Collapse
Affiliation(s)
- X Zhao
- Department of Radiology, Beijing Tiantan Hospital, Capital Medical University, No. 119 Nansihuan Road, Fengtai District, Beijing 100070, China
| | - X Wang
- Department of Radiology, Beijing Tiantan Hospital, Capital Medical University, No. 119 Nansihuan Road, Fengtai District, Beijing 100070, China
| | - S Wang
- Department of Radiology, Beijing Tiantan Hospital, Capital Medical University, No. 119 Nansihuan Road, Fengtai District, Beijing 100070, China
| | - L Chen
- Department of Radiology, Beijing Tiantan Hospital, Capital Medical University, No. 119 Nansihuan Road, Fengtai District, Beijing 100070, China
| | - S Sun
- Department of Radiology, Beijing Tiantan Hospital, Capital Medical University, No. 119 Nansihuan Road, Fengtai District, Beijing 100070, China; Department of Radiology, Beijing Neurosurgical Institute, No. 119 Nansihuan Road, Fengtai District, Beijing 100070, China.
| |
Collapse
|
5
|
Chakravarti S, Uyeda JW. Expanding Role of Dual-Energy CT for Genitourinary Tract Assessment in the Emergency Department, From the AJR Special Series on Emergency Radiology. AJR Am J Roentgenol 2023; 221:720-730. [PMID: 37073900 DOI: 10.2214/ajr.22.27864] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/20/2023]
Abstract
Among explored applications of dual-energy CT (DECT) in the abdomen and pelvis, the genitourinary (GU) tract represents an area where accumulated evidence has established the role of DECT to provide useful information that may change management. This review discusses established applications of DECT for GU tract assessment in the emergency department (ED) setting, including characterization of renal stones, evaluation of traumatic injuries and hemorrhage, and characterization of incidental renal and adrenal findings. Use of DECT for such applications can reduce the need for additional multiphase CT or MRI examinations and reduce follow-up imaging recommendations. Emerging applications are also highlighted, including use of low-energy virtual monoenergetic images (VMIs) to improve image quality and potentially reduce contrast media doses and use of high-energy VMIs to mitigate renal mass pseudoenhancement. Finally, implementation of DECT into busy ED radiology practices is presented, weighing the trade-off of additional image acquisition, processing time, and interpretation time against potential additional useful clinical information. Automatic generation of DECT-derived images with direct PACS transfer can facilitate radiologists' adoption of DECT in busy ED environments and minimize impact on interpretation times. Using the described approaches, radiologists can apply DECT technology to improve the quality and efficiency of care in the ED.
Collapse
Affiliation(s)
| | - Jennifer W Uyeda
- Department of Emergency Radiology, Brigham and Women's Hospital/Harvard Medical School, 75 Francis St, Boston, MA 02115
| |
Collapse
|
6
|
Jeong J, Wentland A, Mastrodicasa D, Fananapazir G, Wang A, Banerjee I, Patel BN. Synthetic dual-energy CT reconstruction from single-energy CT Using artificial intelligence. Abdom Radiol (NY) 2023; 48:3537-3549. [PMID: 37665385 DOI: 10.1007/s00261-023-04004-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2023] [Revised: 06/30/2023] [Accepted: 07/03/2023] [Indexed: 09/05/2023]
Abstract
PURPOSE To develop and assess the utility of synthetic dual-energy CT (sDECT) images generated from single-energy CT (SECT) using two state-of-the-art generative adversarial network (GAN) architectures for artificial intelligence-based image translation. METHODS In this retrospective study, 734 patients (389F; 62.8 years ± 14.9) who underwent enhanced DECT of the chest, abdomen, and pelvis between January 2018 and June 2019 were included. Using 70-keV as the input images (n = 141,009) and 50-keV, iodine, and virtual unenhanced (VUE) images as outputs, separate models were trained using Pix2PixHD and CycleGAN. Model performance on the test set (n = 17,839) was evaluated using mean squared error, structural similarity index, and peak signal-to-noise ratio. To objectively test the utility of these models, synthetic iodine material density and 50-keV images were generated from SECT images of 16 patients with gastrointestinal bleeding performed at another institution. The conspicuity of gastrointestinal bleeding using sDECT was compared to portal venous phase SECT. Synthetic VUE images were generated from 37 patients who underwent a CT urogram at another institution and model performance was compared to true unenhanced images. RESULTS sDECT from both Pix2PixHD and CycleGAN were qualitatively indistinguishable from true DECT by a board-certified radiologist (avg accuracy 64.5%). Pix2PixHD had better quantitative performance compared to CycleGAN (e.g., structural similarity index for iodine: 87% vs. 46%, p-value < 0.001). sDECT using Pix2PixHD showed increased bleeding conspicuity for gastrointestinal bleeding and better removal of iodine on synthetic VUE compared to CycleGAN. CONCLUSIONS sDECT from SECT using Pix2PixHD may afford some of the advantages of DECT.
Collapse
Affiliation(s)
- Jiwoong Jeong
- Department of Radiology, Mayo Clinic, 13400 E. Shea Blvd, Scottsdale, AZ, 85259, USA.
- School of Computing and Augmented Intelligence, Arizona State University, 699 S Mill Ave, Tempe, AZ, 85281, USA.
| | - Andrew Wentland
- Department of Radiology, University of Wisconsin, 600 Highland Ave, Madison, WI, 53792, USA
| | - Domenico Mastrodicasa
- Department of Radiology, Stanford University, 300 Pasteur Dr., Stanford, CA, 94305, USA
| | - Ghaneh Fananapazir
- Department of Radiology, University of California Davis, 4860 Y Street, Suite 3100, Sacramento, CA, 95817, USA
| | - Adam Wang
- Department of Radiology, Stanford University, 300 Pasteur Dr., Stanford, CA, 94305, USA
| | - Imon Banerjee
- Department of Radiology, Mayo Clinic, 13400 E. Shea Blvd, Scottsdale, AZ, 85259, USA
| | - Bhavik N Patel
- Department of Radiology, Mayo Clinic, 13400 E. Shea Blvd, Scottsdale, AZ, 85259, USA
| |
Collapse
|
7
|
van der Star S, de Jong PA, Kok M. Incidental Indeterminate Renal Lesions: Distinguishing Non-Enhancing from Potential Enhancing Renal Lesions Using Iodine Quantification on Portal Venous Dual-Layer Spectral CT. J Pers Med 2023; 13:1546. [PMID: 38003860 PMCID: PMC10672440 DOI: 10.3390/jpm13111546] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2023] [Revised: 10/23/2023] [Accepted: 10/26/2023] [Indexed: 11/26/2023] Open
Abstract
The purpose of our study is to determine a threshold for iodine quantification to distinguish definitely non-enhancing benign renal lesions from potential enhancing masses on portal venous dual-layer spectral computed tomography (CT) to reduce the need for additional multiphase CT. In this single-center retrospective study, patients (≥18 years) scanned between April 2021 and January 2023 following the local renal CT protocol were included. Exclusion criteria were patients without renal lesions, lesions smaller than 10 mm, only fat-containing lesions, abscesses or infarction, follow-up after radiofrequent ablation, wrong scan protocol, or artefacts. Scans were performed on a dual layer detector-based spectral CT (CT 7500, Philips Healthcare, Best, The Netherlands). Iodine concentration (mgI/mL) in renal lesions was determined using spectral data. Analyses were performed for all lesions and for lesions of >30 HU on portal venous CT. Enhancement on multiphase CT (≥20 ΔHU from true unenhanced (TUE) to portal venous phase (PVP) CT) was used as reference standard. To determine thresholds for iodine concentration receiver operating characteristic (ROC) curves, area under the curve (AUC) and 95% confidence intervals were calculated. To obtain thresholds for definite (non-)enhancement, 100% sensitivity with maximum specificity and 100% specificity with maximum sensitivity were noted. Data were measured using one reader. To assess interobserver agreement, a second reader performed measurements on the PVP CT scans. A total of 103 patients (62 years ± 14, 68 men) were included. We measured 328 renal lesions, 56 enhancing lesions (17%) in 38 patients and 272 non-enhancing lesions (83%) in 86 patients. The threshold for non-enhancing lesions was 0.76 mgI/mL or lower (100% sensitivity, 76% specificity). The threshold for a definite enhancing mass was 1.69 mgI/mL or higher (100% specificity, 78% sensitivity). A total of 77% of indeterminate lesions (>30 HU on PVP CT) in our study could be definitely characterized. Renal lesions can be definitively classified as non-enhancing or enhancing on PVP spectral CT using thresholds of 0.76 mgI/mL or 1.69 mgI/mL, respectively, eliminating the need for multiphase imaging.
Collapse
Affiliation(s)
- Simone van der Star
- Department of Radiology, University Medical Center Utrecht, P.O. Box 85500, 3584 CX Utrecht, The Netherlands; (P.A.d.J.); (M.K.)
| | | | | |
Collapse
|
8
|
Zhang X, Zhang G, Xu L, Bai X, Zhang J, Chen L, Lu X, Yu S, Jin Z, Sun H. Prediction of World Health Organization /International Society of Urological Pathology (WHO/ISUP) Pathological Grading of Clear Cell Renal Cell Carcinoma by Dual-Layer Spectral CT. Acad Radiol 2023; 30:2321-2328. [PMID: 36543688 DOI: 10.1016/j.acra.2022.12.002] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2022] [Revised: 11/27/2022] [Accepted: 12/02/2022] [Indexed: 12/24/2022]
Abstract
RATIONALE AND OBJECTIVES To evaluate whether the dual-layer spectral computed tomography urography (DL-CTU) images could predict WHO/ISUP pathological grading of clear cell renal cell carcinoma (ccRCC). MATERIALS AND METHODS We retrospectively included patients (n = 50) with pathologically confirmed ccRCC who underwent preoperative DL-CTU (from October 2017 to February 2021). They were divided into low-grade (WHO/ISUP 1/2, n = 30) and high-grade groups (WHO/ISUP 3/4, n = 20). The lesion size, attenuation (HU), iodine concentration (IC), normalized IC(NIC), and other quantitative characteristics were compared between the two groups. HU, IC, and NIC were obtained by plotting ROI with two different methods (circular ROI in the solid component or irregular ROI along the tumor edge containing tumor necrotic components). Receiver operating characteristic curves and multivariable model were used to evaluate the ability of parameters to predict WHO/ISUP grade. RESULTS Transverse diameter (TD) of low-grade tumors was smaller, and HU in the non-contrast phase of the second method (HU-U-2) was lower than that of high-grade tumors (34.21±15.14 mm vs. 46.50 ± 20.68 mm, 27.33 ± 6.65 HU vs. 31.36 ± 6.09 HU, p< 0.05). The NIC in the nephrographic phase by the two methods (NIC-N-1 and NIC-N-2) of low-grade was higher than that of the high-grade group (0.78± 0.19 vs.0.58 ± 0.22, 0.73 ± 0.42 vs. 0.46 ± 0.22, p< 0.05). The final multivariable model composed of TD, HU-U-2, and NIC-N-1 could predict ccRCC grade with the area under the curve, sensitivity, specificity, and accuracy of 0.852, 70%, 90%, and 82%. CONCLUSION Quantitative indicators in DL-CTU images could help predict the WHO/ISUP grade of ccRCC.
Collapse
Affiliation(s)
- Xiaoxiao Zhang
- Department of Radiology, State Key Laboratory of Complex Severe and Rare Disease, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, BJ, P.R.China
| | - Gumuyang Zhang
- Department of Radiology, State Key Laboratory of Complex Severe and Rare Disease, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, BJ, P.R.China
| | - Lili Xu
- Department of Radiology, State Key Laboratory of Complex Severe and Rare Disease, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, BJ, P.R.China
| | - Xin Bai
- Department of Radiology, State Key Laboratory of Complex Severe and Rare Disease, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, BJ, P.R.China
| | - Jiahui Zhang
- Department of Radiology, State Key Laboratory of Complex Severe and Rare Disease, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, BJ, P.R.China
| | - Li Chen
- Department of Radiology, State Key Laboratory of Complex Severe and Rare Disease, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, BJ, P.R.China
| | - Xiaomei Lu
- CT Clinical Science, Philips Healthcare, Beijing, BJ, P.R.China
| | - Shenghui Yu
- CT Clinical Science, Philips Healthcare, Beijing, BJ, P.R.China
| | - Zhengyu Jin
- Department of Radiology, State Key Laboratory of Complex Severe and Rare Disease, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, BJ, P.R.China; National Center for Quality Control of Radiology, Beijing BJ, P.R.China
| | - Hao Sun
- Department of Radiology, State Key Laboratory of Complex Severe and Rare Disease, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, BJ, P.R.China; National Center for Quality Control of Radiology, Beijing BJ, P.R.China.
| |
Collapse
|
9
|
Cano Alonso R, Álvarez Vázquez A, Andreu Vázquez C, Thuissard Vasallo IJ, Fernández Alfonso A, Recio Rodríguez M, Martínez de Vega V. Dual-energy CT in the differentiation between adrenal adenomas and metastases: Usefulness of material density maps and monochromatic images. RADIOLOGIA 2023; 65:402-413. [PMID: 37758331 DOI: 10.1016/j.rxeng.2021.10.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2021] [Accepted: 10/15/2021] [Indexed: 10/03/2023]
Abstract
OBJECTIVE To evaluate the behavior of adrenal adenomas and metastases with dual-energy CT, analyzing the attenuation coefficient in monochromatic images at three different levels of energy (45, 70, and 140 keV) and the tissue concentrations of fat, water, and iodine in material density maps, with the aim of establishing optimal cutoffs for differentiating between these lesions and comparing our results against published evidence. MATERIALS AND METHODS This retrospective case-control study included oncologic patients diagnosed with adrenal metastases in the 6-12 months prior to the study who were followed up in our hospital between January and June 2020. For each case (patient with metastases) included in the study, we selected a control (patient with an adrenal adenoma) with a nodule of similar size. All patients were studied with a rapid-kilovoltage-switching dual-energy CT scanner, using a biphasic acquisition protocol. We analyzed the concentration of iodine in paired water-iodine images, the concentration of fat in the paired water-fat images, and the concentration of water in the paired iodine-water and fat-water images, in both the arterial and portal phases. We also analyzed the attenuation coefficient in monochromatic images (at 55, 70, and 140 keV) in the arterial and portal phases. RESULTS In the monochromatic images, in both the arterial and portal phases, the attenuation coefficient at all energy levels was significantly higher in the group of patients with metastases than in the group of patients with adenomas. This enabled us to calculate the optimal cutoffs for classifying lesions as adenomas or metastases, except for the arterial phase at 55 KeV, where the area under the receiver operating characteristic curve (AUC) for the estimated threshold (0.68) was not considered accurate enough to classify the lesions. For the arterial phase at 70 keV, the AUC was 0.76 (95% CI: 0.663‒0.899); the optimal cutoff (42.4 HU) yielded 92% sensitivity and 60% specificity. For the arterial phase at 140 keV, the AUC was 0.94 (95% CI: 0.894‒0.999); the optimal cutoff (18.9 HU) yielded 88% sensitivity and 94% specificity). For the portal phase at 55 keV, the AUC was 0.76 (95% CI: 0.663‒0.899); the optimal cutoff (95.4 HU) yielded 68% sensitivity and 84% specificity. For the portal phase at 70 keV, the AUC was 0.82 (95% CI: 0.757‒0.955); the optimal cutoff (58.4 HU) yielded 80% sensitivity and 84% specificity. For the portal phase at 140 keV, the AUC was 0.9 (95% CI: 0.834‒0.987); the optimal cutoff (16.35 HU) yielded 96% sensitivity and 84% specificity. In the material density maps, in the arterial phase, significant differences were found only for the iodine-water pair, where the concentration of water was higher in the group with metastases (1018.8 ± 7.6 mg/cm3 vs. 998.6 ± 8.0 mg/cm3 for the group with adenomas, p < 0.001). The AUC was 0.97 (95% CI: 0.893‒0.999); the optimal cutoff (1012.5 mg/cm3) yielded 88% sensitivity and 96% specificity. The iodine-water pair was also significantly higher in metastases (1019.7 ± 12.1 mg/cm3 vs. 998.5 ± 9.1 mg/cm3 in adenomas, p < 0.001). The AUC was 0.926 (95% CI: 0.807‒0.977); the optimal cutoff (1009.5 mg/cm3) yielded 92% sensitivity and 92% specificity. Although significant results were also observed for the fat-water pair in the portal phase, the AUC was insufficient to enable a sufficiently accurate cutoff for classifying the lesions. No significant differences were found in the fat-water maps or iodine-water maps in the arterial or portal phase or in the water-fat map in the arterial phase. CONCLUSIONS Monochromatic images show differences between the behavior of adrenal adenomas and metastases in oncologic patients studied with intravenous-contrast-enhanced CT, where the group of metastases had higher attenuation than the group of adenomas in both the arterial and portal phases; this pattern is in line with the evidence published for adenomas. Nevertheless, to our knowledge, no other publications report cutoffs for this kind of differentiation in contrast-enhanced monochromatic images obtained in rapid-kilovoltage-switching dual-energy CT scanners, and this is the first new contribution of our study. Regarding the material density maps, our results suggest that the water-iodine pair is a good tool for differentiating between adrenal adenomas and metastases, in both the arterial and portal phases. We propose cutoffs for differentiating these lesions, although to our knowledge no cutoffs have been proposed for portal-phase contrast-enhanced images obtained with rapid-kilovoltage-switching dual-energy CT scanners.
Collapse
Affiliation(s)
- R Cano Alonso
- Servicio de Diagnóstico por la Imagen, Hospital Universitario QuironSalud, Pozuelo de Alarcón, Madrid, Spain.
| | - A Álvarez Vázquez
- Servicio de Diagnóstico por la Imagen, Hospital Universitario QuironSalud, Pozuelo de Alarcón, Madrid, Spain
| | - C Andreu Vázquez
- Universidad Europea de Madrid, Facultad de Ciencias Biomédicas y de la Salud, Villaviciosa de Odón, Madrid, Spain
| | - I J Thuissard Vasallo
- Universidad Europea de Madrid, Facultad de Ciencias Biomédicas y de la Salud, Villaviciosa de Odón, Madrid, Spain
| | - A Fernández Alfonso
- Servicio de Diagnóstico por la Imagen, Hospital Universitario QuironSalud, Pozuelo de Alarcón, Madrid, Spain
| | - M Recio Rodríguez
- Servicio de Diagnóstico por la Imagen, Hospital Universitario QuironSalud, Pozuelo de Alarcón, Madrid, Spain
| | - V Martínez de Vega
- Servicio de Diagnóstico por la Imagen, Hospital Universitario QuironSalud, Pozuelo de Alarcón, Madrid, Spain
| |
Collapse
|
10
|
Guerrini S, Bagnacci G, Perrella A, Meglio ND, Sica C, Mazzei MA. Dual Energy CT in Oncology: Benefits for Both Patients and Radiologists From an Emerging Quantitative and Functional Diagnostic Technique. Semin Ultrasound CT MR 2023; 44:205-213. [PMID: 37245885 DOI: 10.1053/j.sult.2023.03.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
Dual-energy CT (DECT) imaging makes it possible to identify the characteristics of materials that cannot be recognized with conventional single-energy CT (SECT). In the postprocessing study phase, virtual monochromatic images and virtual-non-contrast (VNC) images, also permits reduction of dose exposure by eliminating the precontrast acquisition scan. Moreover, in virtual monochromatic images, the iodine contrast increases when the energy level decreases resulting in better visualization of hypervascular lesions and in a better tissue contrast between hypovascular lesions and the surrounding parenchyma; thus, allowing for reduction of required iodinate contrast material, especially important in patients with renal impairment. All these advantages are particularly important in oncology, providing the possibility of overcoming many SECT imaging limits and making CT examinations safer and more feasible in critical patients. This review explores the basis of DECT imaging and its utility in routine oncologic clinical practice, with particular attention to the benefits of this technique for both the patients and the radiologists.
Collapse
Affiliation(s)
- Susanna Guerrini
- Unit of Diagnostic Imaging, Department of Medical Sciences, University of Siena, Azienda Ospedaliero-Universitaria Senese, Siena, Italy.
| | - Giulio Bagnacci
- Diagnostic Imaging Unit, Department of Diagnostic Imaging, Azienda USL-Toscana Sud-Est, Poggibonsi, Valdelsa, Italy
| | - Armando Perrella
- Diagnostic Imaging Unit, Department of Diagnostic Imaging, Azienda USL-Toscana Sud-Est, Grosseto, Italy
| | - Nunzia Di Meglio
- Unit of Diagnostic Imaging, Department of Medical Sciences, University of Siena, Azienda Ospedaliero-Universitaria Senese, Siena, Italy
| | - Cristian Sica
- Unit of Diagnostic Imaging, Department of Medical, Surgical and Neuro Sciences and of Medical Sciences, University of Siena, Azienda Ospedaliero-Universitaria Senese, Siena, Italy
| | - Maria Antonietta Mazzei
- Unit of Diagnostic Imaging, Department of Medical, Surgical and Neuro Sciences and of Medical Sciences, University of Siena, Azienda Ospedaliero-Universitaria Senese, Siena, Italy
| |
Collapse
|
11
|
Dane B, Gupta A, Wells ML, Anderson MA, Fidler JL, Naringrekar HV, Allen BC, Brook OR, Bruining DH, Gee MS, Grand DJ, Kastenberg D, Khandelwal A, Sengupta N, Soto JA, Guglielmo FF. Dual-Energy CT Evaluation of Gastrointestinal Bleeding. Radiographics 2023; 43:e220192. [PMID: 37167088 DOI: 10.1148/rg.220192] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
Gastrointestinal (GI) bleeding is a potentially life-threatening condition accounting for more than 300 000 annual hospitalizations. Multidetector abdominopelvic CT angiography is commonly used in the evaluation of patients with GI bleeding. Given that many patients with severe overt GI bleeding are unlikely to tolerate bowel preparation, and inpatient colonoscopy is frequently limited by suboptimal preparation obscuring mucosal visibility, CT angiography is recommended as a first-line diagnostic test in patients with severe hematochezia to localize a source of bleeding. Assessment of these patients with conventional single-energy CT systems typically requires the performance of a noncontrast series followed by imaging during multiple postcontrast phases. Dual-energy CT (DECT) offers several potential advantages for performing these examinations. DECT may eliminate the need for a noncontrast acquisition by allowing the creation of virtual noncontrast (VNC) images from contrast-enhanced data, affording significant radiation dose reduction while maintaining diagnostic accuracy. VNC images can help radiologists to differentiate active bleeding, hyperattenuating enteric contents, hematomas, and enhancing masses. Additional postprocessing techniques such as low-kiloelectron voltage virtual monoenergetic images, iodine maps, and iodine overlay images can increase the conspicuity of contrast material extravasation and improve the visibility of subtle causes of GI bleeding, thereby increasing diagnostic confidence and assisting with problem solving. GI bleeding can also be diagnosed with routine single-phase DECT scans by constructing VNC images and iodine maps. Radiologists should also be aware of the potential pitfalls and limitations of DECT. ©RSNA, 2023 Quiz questions for this article are available through the Online Learning Center.
Collapse
Affiliation(s)
- Bari Dane
- From the Department of Radiology, NYU Langone Health, 660 1st Ave, New York, NY 10016 (B.D.); Department of Radiology, Boston University Medical Center, Boston, Mass (A.G., J.A.S.); Department of Radiology (M.L.W., J.L.F., A.K.) and Division of Gastroenterology and Hepatology (D.H.B.), Mayo Clinic, Rochester, Minn; Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Mass (M.A.A., M.S.G.); Department of Radiology (H.V.N., F.F.G.) and Division of Gastroenterology (D.K.), Thomas Jefferson University, Philadelphia, Pa; Department of Radiology, Duke University Medical Center, Durham, NC (B.C.A.); Department of Radiology, Beth Israel Deaconess Medical Center, Boston, Mass (O.R.B.); Department of Diagnostic Imaging, The Warren Alpert Medical School of Brown University/Rhode Island Hospital, Providence, RI (D.J.G.); and Division of Gastroenterology, University of Chicago, Chicago, Ill (N.S.)
| | - Avneesh Gupta
- From the Department of Radiology, NYU Langone Health, 660 1st Ave, New York, NY 10016 (B.D.); Department of Radiology, Boston University Medical Center, Boston, Mass (A.G., J.A.S.); Department of Radiology (M.L.W., J.L.F., A.K.) and Division of Gastroenterology and Hepatology (D.H.B.), Mayo Clinic, Rochester, Minn; Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Mass (M.A.A., M.S.G.); Department of Radiology (H.V.N., F.F.G.) and Division of Gastroenterology (D.K.), Thomas Jefferson University, Philadelphia, Pa; Department of Radiology, Duke University Medical Center, Durham, NC (B.C.A.); Department of Radiology, Beth Israel Deaconess Medical Center, Boston, Mass (O.R.B.); Department of Diagnostic Imaging, The Warren Alpert Medical School of Brown University/Rhode Island Hospital, Providence, RI (D.J.G.); and Division of Gastroenterology, University of Chicago, Chicago, Ill (N.S.)
| | - Michael L Wells
- From the Department of Radiology, NYU Langone Health, 660 1st Ave, New York, NY 10016 (B.D.); Department of Radiology, Boston University Medical Center, Boston, Mass (A.G., J.A.S.); Department of Radiology (M.L.W., J.L.F., A.K.) and Division of Gastroenterology and Hepatology (D.H.B.), Mayo Clinic, Rochester, Minn; Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Mass (M.A.A., M.S.G.); Department of Radiology (H.V.N., F.F.G.) and Division of Gastroenterology (D.K.), Thomas Jefferson University, Philadelphia, Pa; Department of Radiology, Duke University Medical Center, Durham, NC (B.C.A.); Department of Radiology, Beth Israel Deaconess Medical Center, Boston, Mass (O.R.B.); Department of Diagnostic Imaging, The Warren Alpert Medical School of Brown University/Rhode Island Hospital, Providence, RI (D.J.G.); and Division of Gastroenterology, University of Chicago, Chicago, Ill (N.S.)
| | - Mark A Anderson
- From the Department of Radiology, NYU Langone Health, 660 1st Ave, New York, NY 10016 (B.D.); Department of Radiology, Boston University Medical Center, Boston, Mass (A.G., J.A.S.); Department of Radiology (M.L.W., J.L.F., A.K.) and Division of Gastroenterology and Hepatology (D.H.B.), Mayo Clinic, Rochester, Minn; Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Mass (M.A.A., M.S.G.); Department of Radiology (H.V.N., F.F.G.) and Division of Gastroenterology (D.K.), Thomas Jefferson University, Philadelphia, Pa; Department of Radiology, Duke University Medical Center, Durham, NC (B.C.A.); Department of Radiology, Beth Israel Deaconess Medical Center, Boston, Mass (O.R.B.); Department of Diagnostic Imaging, The Warren Alpert Medical School of Brown University/Rhode Island Hospital, Providence, RI (D.J.G.); and Division of Gastroenterology, University of Chicago, Chicago, Ill (N.S.)
| | - Jeff L Fidler
- From the Department of Radiology, NYU Langone Health, 660 1st Ave, New York, NY 10016 (B.D.); Department of Radiology, Boston University Medical Center, Boston, Mass (A.G., J.A.S.); Department of Radiology (M.L.W., J.L.F., A.K.) and Division of Gastroenterology and Hepatology (D.H.B.), Mayo Clinic, Rochester, Minn; Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Mass (M.A.A., M.S.G.); Department of Radiology (H.V.N., F.F.G.) and Division of Gastroenterology (D.K.), Thomas Jefferson University, Philadelphia, Pa; Department of Radiology, Duke University Medical Center, Durham, NC (B.C.A.); Department of Radiology, Beth Israel Deaconess Medical Center, Boston, Mass (O.R.B.); Department of Diagnostic Imaging, The Warren Alpert Medical School of Brown University/Rhode Island Hospital, Providence, RI (D.J.G.); and Division of Gastroenterology, University of Chicago, Chicago, Ill (N.S.)
| | - Haresh V Naringrekar
- From the Department of Radiology, NYU Langone Health, 660 1st Ave, New York, NY 10016 (B.D.); Department of Radiology, Boston University Medical Center, Boston, Mass (A.G., J.A.S.); Department of Radiology (M.L.W., J.L.F., A.K.) and Division of Gastroenterology and Hepatology (D.H.B.), Mayo Clinic, Rochester, Minn; Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Mass (M.A.A., M.S.G.); Department of Radiology (H.V.N., F.F.G.) and Division of Gastroenterology (D.K.), Thomas Jefferson University, Philadelphia, Pa; Department of Radiology, Duke University Medical Center, Durham, NC (B.C.A.); Department of Radiology, Beth Israel Deaconess Medical Center, Boston, Mass (O.R.B.); Department of Diagnostic Imaging, The Warren Alpert Medical School of Brown University/Rhode Island Hospital, Providence, RI (D.J.G.); and Division of Gastroenterology, University of Chicago, Chicago, Ill (N.S.)
| | - Brian C Allen
- From the Department of Radiology, NYU Langone Health, 660 1st Ave, New York, NY 10016 (B.D.); Department of Radiology, Boston University Medical Center, Boston, Mass (A.G., J.A.S.); Department of Radiology (M.L.W., J.L.F., A.K.) and Division of Gastroenterology and Hepatology (D.H.B.), Mayo Clinic, Rochester, Minn; Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Mass (M.A.A., M.S.G.); Department of Radiology (H.V.N., F.F.G.) and Division of Gastroenterology (D.K.), Thomas Jefferson University, Philadelphia, Pa; Department of Radiology, Duke University Medical Center, Durham, NC (B.C.A.); Department of Radiology, Beth Israel Deaconess Medical Center, Boston, Mass (O.R.B.); Department of Diagnostic Imaging, The Warren Alpert Medical School of Brown University/Rhode Island Hospital, Providence, RI (D.J.G.); and Division of Gastroenterology, University of Chicago, Chicago, Ill (N.S.)
| | - Olga R Brook
- From the Department of Radiology, NYU Langone Health, 660 1st Ave, New York, NY 10016 (B.D.); Department of Radiology, Boston University Medical Center, Boston, Mass (A.G., J.A.S.); Department of Radiology (M.L.W., J.L.F., A.K.) and Division of Gastroenterology and Hepatology (D.H.B.), Mayo Clinic, Rochester, Minn; Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Mass (M.A.A., M.S.G.); Department of Radiology (H.V.N., F.F.G.) and Division of Gastroenterology (D.K.), Thomas Jefferson University, Philadelphia, Pa; Department of Radiology, Duke University Medical Center, Durham, NC (B.C.A.); Department of Radiology, Beth Israel Deaconess Medical Center, Boston, Mass (O.R.B.); Department of Diagnostic Imaging, The Warren Alpert Medical School of Brown University/Rhode Island Hospital, Providence, RI (D.J.G.); and Division of Gastroenterology, University of Chicago, Chicago, Ill (N.S.)
| | - David H Bruining
- From the Department of Radiology, NYU Langone Health, 660 1st Ave, New York, NY 10016 (B.D.); Department of Radiology, Boston University Medical Center, Boston, Mass (A.G., J.A.S.); Department of Radiology (M.L.W., J.L.F., A.K.) and Division of Gastroenterology and Hepatology (D.H.B.), Mayo Clinic, Rochester, Minn; Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Mass (M.A.A., M.S.G.); Department of Radiology (H.V.N., F.F.G.) and Division of Gastroenterology (D.K.), Thomas Jefferson University, Philadelphia, Pa; Department of Radiology, Duke University Medical Center, Durham, NC (B.C.A.); Department of Radiology, Beth Israel Deaconess Medical Center, Boston, Mass (O.R.B.); Department of Diagnostic Imaging, The Warren Alpert Medical School of Brown University/Rhode Island Hospital, Providence, RI (D.J.G.); and Division of Gastroenterology, University of Chicago, Chicago, Ill (N.S.)
| | - Michael S Gee
- From the Department of Radiology, NYU Langone Health, 660 1st Ave, New York, NY 10016 (B.D.); Department of Radiology, Boston University Medical Center, Boston, Mass (A.G., J.A.S.); Department of Radiology (M.L.W., J.L.F., A.K.) and Division of Gastroenterology and Hepatology (D.H.B.), Mayo Clinic, Rochester, Minn; Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Mass (M.A.A., M.S.G.); Department of Radiology (H.V.N., F.F.G.) and Division of Gastroenterology (D.K.), Thomas Jefferson University, Philadelphia, Pa; Department of Radiology, Duke University Medical Center, Durham, NC (B.C.A.); Department of Radiology, Beth Israel Deaconess Medical Center, Boston, Mass (O.R.B.); Department of Diagnostic Imaging, The Warren Alpert Medical School of Brown University/Rhode Island Hospital, Providence, RI (D.J.G.); and Division of Gastroenterology, University of Chicago, Chicago, Ill (N.S.)
| | - David J Grand
- From the Department of Radiology, NYU Langone Health, 660 1st Ave, New York, NY 10016 (B.D.); Department of Radiology, Boston University Medical Center, Boston, Mass (A.G., J.A.S.); Department of Radiology (M.L.W., J.L.F., A.K.) and Division of Gastroenterology and Hepatology (D.H.B.), Mayo Clinic, Rochester, Minn; Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Mass (M.A.A., M.S.G.); Department of Radiology (H.V.N., F.F.G.) and Division of Gastroenterology (D.K.), Thomas Jefferson University, Philadelphia, Pa; Department of Radiology, Duke University Medical Center, Durham, NC (B.C.A.); Department of Radiology, Beth Israel Deaconess Medical Center, Boston, Mass (O.R.B.); Department of Diagnostic Imaging, The Warren Alpert Medical School of Brown University/Rhode Island Hospital, Providence, RI (D.J.G.); and Division of Gastroenterology, University of Chicago, Chicago, Ill (N.S.)
| | - David Kastenberg
- From the Department of Radiology, NYU Langone Health, 660 1st Ave, New York, NY 10016 (B.D.); Department of Radiology, Boston University Medical Center, Boston, Mass (A.G., J.A.S.); Department of Radiology (M.L.W., J.L.F., A.K.) and Division of Gastroenterology and Hepatology (D.H.B.), Mayo Clinic, Rochester, Minn; Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Mass (M.A.A., M.S.G.); Department of Radiology (H.V.N., F.F.G.) and Division of Gastroenterology (D.K.), Thomas Jefferson University, Philadelphia, Pa; Department of Radiology, Duke University Medical Center, Durham, NC (B.C.A.); Department of Radiology, Beth Israel Deaconess Medical Center, Boston, Mass (O.R.B.); Department of Diagnostic Imaging, The Warren Alpert Medical School of Brown University/Rhode Island Hospital, Providence, RI (D.J.G.); and Division of Gastroenterology, University of Chicago, Chicago, Ill (N.S.)
| | - Ashish Khandelwal
- From the Department of Radiology, NYU Langone Health, 660 1st Ave, New York, NY 10016 (B.D.); Department of Radiology, Boston University Medical Center, Boston, Mass (A.G., J.A.S.); Department of Radiology (M.L.W., J.L.F., A.K.) and Division of Gastroenterology and Hepatology (D.H.B.), Mayo Clinic, Rochester, Minn; Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Mass (M.A.A., M.S.G.); Department of Radiology (H.V.N., F.F.G.) and Division of Gastroenterology (D.K.), Thomas Jefferson University, Philadelphia, Pa; Department of Radiology, Duke University Medical Center, Durham, NC (B.C.A.); Department of Radiology, Beth Israel Deaconess Medical Center, Boston, Mass (O.R.B.); Department of Diagnostic Imaging, The Warren Alpert Medical School of Brown University/Rhode Island Hospital, Providence, RI (D.J.G.); and Division of Gastroenterology, University of Chicago, Chicago, Ill (N.S.)
| | - Neil Sengupta
- From the Department of Radiology, NYU Langone Health, 660 1st Ave, New York, NY 10016 (B.D.); Department of Radiology, Boston University Medical Center, Boston, Mass (A.G., J.A.S.); Department of Radiology (M.L.W., J.L.F., A.K.) and Division of Gastroenterology and Hepatology (D.H.B.), Mayo Clinic, Rochester, Minn; Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Mass (M.A.A., M.S.G.); Department of Radiology (H.V.N., F.F.G.) and Division of Gastroenterology (D.K.), Thomas Jefferson University, Philadelphia, Pa; Department of Radiology, Duke University Medical Center, Durham, NC (B.C.A.); Department of Radiology, Beth Israel Deaconess Medical Center, Boston, Mass (O.R.B.); Department of Diagnostic Imaging, The Warren Alpert Medical School of Brown University/Rhode Island Hospital, Providence, RI (D.J.G.); and Division of Gastroenterology, University of Chicago, Chicago, Ill (N.S.)
| | - Jorge A Soto
- From the Department of Radiology, NYU Langone Health, 660 1st Ave, New York, NY 10016 (B.D.); Department of Radiology, Boston University Medical Center, Boston, Mass (A.G., J.A.S.); Department of Radiology (M.L.W., J.L.F., A.K.) and Division of Gastroenterology and Hepatology (D.H.B.), Mayo Clinic, Rochester, Minn; Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Mass (M.A.A., M.S.G.); Department of Radiology (H.V.N., F.F.G.) and Division of Gastroenterology (D.K.), Thomas Jefferson University, Philadelphia, Pa; Department of Radiology, Duke University Medical Center, Durham, NC (B.C.A.); Department of Radiology, Beth Israel Deaconess Medical Center, Boston, Mass (O.R.B.); Department of Diagnostic Imaging, The Warren Alpert Medical School of Brown University/Rhode Island Hospital, Providence, RI (D.J.G.); and Division of Gastroenterology, University of Chicago, Chicago, Ill (N.S.)
| | - Flavius F Guglielmo
- From the Department of Radiology, NYU Langone Health, 660 1st Ave, New York, NY 10016 (B.D.); Department of Radiology, Boston University Medical Center, Boston, Mass (A.G., J.A.S.); Department of Radiology (M.L.W., J.L.F., A.K.) and Division of Gastroenterology and Hepatology (D.H.B.), Mayo Clinic, Rochester, Minn; Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Mass (M.A.A., M.S.G.); Department of Radiology (H.V.N., F.F.G.) and Division of Gastroenterology (D.K.), Thomas Jefferson University, Philadelphia, Pa; Department of Radiology, Duke University Medical Center, Durham, NC (B.C.A.); Department of Radiology, Beth Israel Deaconess Medical Center, Boston, Mass (O.R.B.); Department of Diagnostic Imaging, The Warren Alpert Medical School of Brown University/Rhode Island Hospital, Providence, RI (D.J.G.); and Division of Gastroenterology, University of Chicago, Chicago, Ill (N.S.)
| |
Collapse
|
12
|
Xu JJ, Ulriksen PS, Bjerrum CW, Achiam MP, Resch TA, Lönn L, Lindskov Hansen K. Characterizing incidental mass lesions in abdominal dual-energy CT compared to conventional contrast-enhanced CT. Acta Radiol 2023; 64:945-950. [PMID: 35918808 DOI: 10.1177/02841851221116306] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Incidental findings are common in abdominal computed tomography (CT) and often warrant further investigations with economic implications as well as implications for patients. PURPOSE To evaluate the potential of dual-energy CT (DECT) in the identification and/or characterization of abdominal incidental mass lesions compared to conventional contrast-enhanced CT. MATERIAL AND METHODS This retrospective study from a major tertiary hospital included 96 patients, who underwent contrast-enhanced abdominal DECT. Incidental lesions in adrenals, kidneys, liver, and pancreas were evaluated by two board-certified abdominal radiologists. Observer 1 only had access to standard CT reconstructions, while observer 2 had access to standard CT as well as DECT reconstructions. Disagreements were resolved by consensus review and used as a reference for observers using McNemar's test. RESULTS Observers 1 and 2 identified a total of 40 and 34 findings, respectively. Furthermore, observer 1 registered 13 lesions requiring follow-up, of which seven (two renal and five adrenal lesions) were resolved following consensus review using DECT (P = 0.008). The inter-observer agreement was near perfect (κ = 0.82). CONCLUSION DECT has the potential to improve the immediate characterization of incidental findings when compared to conventional CT for abdominal imaging.
Collapse
Affiliation(s)
- Jack Junchi Xu
- Department of Diagnostic Radiology, Copenhagen University Hospital, 53146Rigshospitalet, Copenhagen, Denmark
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| | - Peter Sommer Ulriksen
- Department of Diagnostic Radiology, Copenhagen University Hospital, 53146Rigshospitalet, Copenhagen, Denmark
| | - Camilla Wium Bjerrum
- Department of Diagnostic Radiology, Copenhagen University Hospital, 53146Rigshospitalet, Copenhagen, Denmark
| | - Michael Patrick Achiam
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
- Department of Surgical Gastroenterology, Copenhagen University Hospital, 53146Rigshospitalet, Copenhagen, Denmark
| | - Timothy Andrew Resch
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
- Department of Vascular Surgery, Copenhagen University Hospital, 53146Rigshospitalet, Copenhagen, Denmark
| | - Lars Lönn
- Department of Diagnostic Radiology, Copenhagen University Hospital, 53146Rigshospitalet, Copenhagen, Denmark
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| | - Kristoffer Lindskov Hansen
- Department of Diagnostic Radiology, Copenhagen University Hospital, 53146Rigshospitalet, Copenhagen, Denmark
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
13
|
Galluzzo A, Danti G, Bicci E, Mastrorosato M, Bertelli E, Miele V. The role of Dual-Energy CT in the study of urinary tract tumours: review of recent literature. Semin Ultrasound CT MR 2023; 44:136-144. [DOI: 10.1053/j.sult.2023.03.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/09/2023]
|
14
|
Editorial Comment: Toward Precise and Reproducible Iodine Quantification With Dual-Energy CT-Getting Closer, but Not There Yet. AJR Am J Roentgenol 2022; 219:840. [PMID: 35766537 DOI: 10.2214/ajr.22.28159] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
15
|
Multivendor Comparison of Quantification Accuracy of Iodine Concentration and Attenuation Measurements by Dual-Energy CT: A Phantom Study. AJR Am J Roentgenol 2022; 219:827-839. [PMID: 35674353 DOI: 10.2214/ajr.22.27753] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
BACKGROUND. Studies comparing accuracy of quantification by dual-energy CT (DECT) scanners have been limited by small numbers of scanners evaluated and narrow ranges of scanning conditions. OBJECTIVE. The purpose of this study was to compare DECT scanners of varying vendors, technologies, and generations in terms of the accuracy of iodine concentration and attenuation measurements. METHODS. A DECT quality-control phantom was designed to contain seven inserts of varying iodine concentrations as well as soft-tissue and fat inserts. The phantom underwent DECT using 12 different scanner configurations based on seven different DECT scanners from three vendors, with additional variation in tube voltage settings. Technologies included rapid-switching, dual-source, and dual-layer detector DECT. Scans also used three radiation dose levels (10, 20, and 30 mGy) and multiple reconstruction algorithms (filtered back projection, medium and high iterative reconstruction, and deep learning image reconstruction [DLIR]). The mean absolute percentage error (MAPE, representing the absolute ratio of measured error to nominal values on average; lower values indicate better accuracy) was calculated for iodine concentration on iodine maps (MAPEiodine) and attenuation on virtual monochromatic images (VMIs) using 40, 70, 100, and 140 keV (MAPEHU). Linear mixed models were used to explore factors affecting quantification accuracy. RESULTS. MAPEiodine and MAPEHU ranged 4.62-28.55% and 10.21-26.33%, respectively, across scanner configurations. Accuracies of iodine concentration and attenuation measurements were higher for third-generation rapid-switching and dual-source scanners in comparison with respective earlier-generation scanners and the single evaluated dual-layer detector scanner. Among all configurations, the third-generation rapid-switching scanner using DLIR had the highest quantification accuracy for iodine concentration (MAPEiodine, 4.62% ± 3.87%) and attenuation (MAPEHU, 10.21% ± 11.43%). Overall, MAPEiodine was significantly affected by scanner configuration (F = 450.0, p < .001) and iodine concentration (F = 211.0, p < .001). Overall, MAPEHU was significantly affected by scanner configuration (F = 233.5, p < .001), radiation dose (F = 14.9, p < .001), VMI energy level (F = 1959.4, p < .001), and material density (F = 411.5, p < .001); radiation dose was significantly associated with MAPEHU for five of 12 individual configurations. CONCLUSION. Quantification accuracy varied among DECT configurations of varying vendors, platforms, and generations and was affected by acquisition and reconstruction parameters. DLIR may improve quantification accuracy. CLINICAL IMPACT. The interscanner differences in DECT-based measurements should be recognized when quantitative evaluation is performed by DECT in clinical practice.
Collapse
|
16
|
Development of a Multiparametric Renal CT Algorithm for Diagnosis of Clear Cell Renal Cell Carcinoma Among Small (≤ 4 cm) Solid Renal Masses. AJR Am J Roentgenol 2022; 219:814-823. [PMID: 35766532 DOI: 10.2214/ajr.22.27971] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
BACKGROUND. The MRI clear cell likelihood score predicts the likelihood that a renal mass is clear cell renal cell carcinoma (ccRCC). A CT-based algorithm has not yet been established. OBJECTIVE. The purpose of our study was to develop and evaluate a CT-based algorithm for diagnosing ccRCC among small (≤ 4 cm) solid renal masses. METHODS. This retrospective study included 148 patients (73 men, 75 women; mean age, 58 ± 12 [SD] years) with 148 small (≤ 4 cm) solid (> 25% enhancing tissue) renal masses that underwent renal mass CT (unenhanced, corticomedullary, and nephrographic phases) before resection between January 2016 and December 2019. Two radiologists independently evaluated CT examinations and recorded calcification, mass attenuation in all phases, mass-to-cortex corticomedullary attenuation ratio, and heterogeneity score (score on a 5-point Likert scale, assessed in corticomedullary phase). Features associated with ccRCC were identified by multivariable logistic regression analysis and then used to create a five-tiered CT score for diagnosing ccRCC. RESULTS. The masses comprised 53% (78/148) ccRCC and 47% (70/148) other histologic diagnoses. The mass-to-cortex corticomedullary attenuation ratio was higher for ccRCC than for other diagnoses (reader 1: 0.84 ± 0.68 vs 0.68 ± 0.65, p = .02; reader 2: 0.75 ± 0.29 vs 0.59 ± 0.25, p = .02). The heterogeneity score was higher for ccRCC than other diagnoses (reader 1: 4.0 ± 1.1 vs 1.5 ± 1.6, p < .001; reader 2: 4.4 ± 0.9 vs 3.3 ± 1.5, p < .001). Other features showed no difference. A five-tiered diagnostic algorithm including the mass-to-cortex corticomedullary attenuation ratio and heterogeneity score had interobserver agreement of 0.71 (weighted κ) and achieved an AUC for diagnosing ccRCC of 0.75 (95% CI, 0.68-0.82) for reader 1 and 0.72 (95% CI, 0.66-0.82) for reader 2. A CT score of 4 or greater achieved sensitivity, specificity, and PPV of 71% (95% CI, 59-80%), 79% (95% CI, 67-87%), and 79% (95% CI, 67-87%) for reader 1 and 42% (95% CI, 31-54%), 81% (95% CI, 70-90%), and 72% (95% CI, 56-84%) for reader 2. A CT score of 2 or less had NPV of 85% (95% CI, 69-95%) for reader 1 and 88% (95% CI, 69-97%) for reader 2. CONCLUSION. A five-tiered renal CT algorithm, including the mass-to-cortex corticomedullary attenuation ratio and heterogeneity score, had substantial interobserver agreement, moderate AUC and PPV, and high NPV for diagnosing ccRCC. CLINICAL IMPACT. The CT algorithm, if validated, may represent a useful clinical tool for diagnosing ccRCC.
Collapse
|
17
|
Ma C, Xu D, Hui Q, Gao X, Peng M. Quantitative Intracerebral Iodine Extravasation in Risk Stratification for Intracranial Hemorrhage in Patients with Acute Ischemic Stroke. AJNR Am J Neuroradiol 2022; 43:1589-1596. [PMID: 36202552 PMCID: PMC9731239 DOI: 10.3174/ajnr.a7671] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2022] [Accepted: 09/07/2022] [Indexed: 02/01/2023]
Abstract
BACKGROUND AND PURPOSE Intracerebral hemorrhage poses a severe threat to the outcomes in patients with postthrombectomy acute stroke. We aimed to compare the absolute intracerebral iodine concentration and normalized iodine concentration ratio in predicting intracerebral hemorrhage in patients postthrombectomy. MATERIALS AND METHODS Patients with acute anterior circulation large-vessel occlusion who underwent mechanical thrombectomy and had successful recanalization were retrospectively included in the study. Dual-energy CT was performed within 1 hour after mechanical thrombectomy. Postprocessing was performed to measure the absolute intracerebral iodine concentration and the normalized iodine concentration ratio. The correlation between the absolute intracerebral iodine concentration and the normalized iodine concentration ratio was analyzed using the Spearman rank correlation coefficient. We compared the area under the receiver operating characteristic curve of the absolute intracerebral iodine concentration and the normalized iodine concentration ratio using the DeLong test. RESULTS We included 138 patients with successful recanalization. Of 43 patients who did not have parenchymal contrast staining on postthrombectomy dual-energy CT, 5 (11.6%) developed intracerebral hemorrhage. Among patients (95/138, 68.8%) with parenchymal contrast staining, 37 (38.9%, 37/95) developed intracerebral hemorrhage. The absolute intracerebral iodine concentration was significantly correlated with the normalized iodine concentration ratio (ρ = 0.807; 95% CI, 0.718-0.867; P < .001). The cutoffs of the normalized iodine concentration ratio and absolute intracerebral iodine concentration for identifying patients with intracerebral hemorrhage development were 222.8%, with a sensitivity of 67.6% and specificity of 76.4%, and 2.7 mg I/mL, with a sensitivity of 75.7% and specificity of 65.5%, respectively. No significant difference was found between the areas under the receiver operating characteristic curve for the absolute intracerebral iodine concentration and the normalized iodine concentration ratio (0.753 versus 0.738) (P = .694). CONCLUSIONS The hemorrhagic transformation predictive power of the normalized iodine concentration ratio is similar to that of the absolute intracerebral iodine concentration in patients with successful recanalization.
Collapse
Affiliation(s)
- C Ma
- From the Departments of Radiology (C.M., Q.H., X.G.)
| | | | - Q Hui
- From the Departments of Radiology (C.M., Q.H., X.G.)
| | - X Gao
- From the Departments of Radiology (C.M., Q.H., X.G.)
| | - M Peng
- Neurology (M.P.), Deyang People's Hospital, Deyang, Sichuan, China
| |
Collapse
|
18
|
Toia GV, Mileto A, Wang CL, Sahani DV. Quantitative dual-energy CT techniques in the abdomen. Abdom Radiol (NY) 2022; 47:3003-3018. [PMID: 34468796 DOI: 10.1007/s00261-021-03266-7] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2021] [Revised: 08/25/2021] [Accepted: 08/26/2021] [Indexed: 02/06/2023]
Abstract
Advances in dual-energy CT (DECT) technology and spectral techniques are catalyzing the widespread implementation of this technology across multiple radiology subspecialties. The inclusion of energy- and material-specific datasets has ushered overall improvements in CT image contrast and noise as well as artifacts reduction, leading to considerable progress in radiologists' ability to detect and characterize pathologies in the abdomen. The scope of this article is to provide an overview of various quantitative clinical DECT applications in the abdomen and pelvis. Several of the reviewed applications have not reached mainstream clinical use and are considered investigational. Nonetheless awareness of such applications is critical to having a fully comprehensive knowledge base to DECT and fostering future clinical implementation.
Collapse
Affiliation(s)
- Giuseppe V Toia
- Department of Radiology, University of Wisconsin School of Medicine and Public Health, 600 Highland Avenue, Mailbox 3252, Madison, WI, 53792, USA.
| | - Achille Mileto
- Department of Radiology, Mayo Clinic, 200 First Street, SW, Rochester, MN, 55905, USA
| | - Carolyn L Wang
- Department of Radiology, University of Washington School of Medicine, 1959 NE Pacific Street, Seattle, WA, 98195, USA
| | - Dushyant V Sahani
- Department of Radiology, University of Washington School of Medicine, 1959 NE Pacific Street, Seattle, WA, 98195, USA
| |
Collapse
|
19
|
Ersahin D, Rasla J, Singh A. Dual energy CT applications in oncological imaging. Semin Ultrasound CT MR 2022; 43:344-351. [PMID: 35738819 DOI: 10.1053/j.sult.2022.04.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Cancer is the second leading cause of death in the United States, killing more than 600.000 people each year.1 Despite several screening programs available, cancer diagnosis is often made incidentally during imaging studies performed for other reasons. Once the diagnosis is made, treatment assessment and surveillance of these patients heavily rely on radiological tools. Computed tomography (CT) in particular is one of the most commonly ordered modalities due to wide availability even in the most remote locations, and fast results. However, conventional CT often cannot definitively characterize a neoplastic lesion unless it was tailored toward answering a specific question. Furthermore, characterizing small lesions can be difficult with CT. An innovative technique called dual-energy CT (DECT) offers solutions to some of the challenges of conventional CT in oncological imaging.
Collapse
|
20
|
Singh R, Rai R, Mroueh N, Kambadakone A. Role of Dual Energy Computed Tomography in Inflammatory Bowel Disease. Semin Ultrasound CT MR 2022; 43:320-332. [PMID: 35738817 DOI: 10.1053/j.sult.2022.03.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
Dual-energy computed tomography (DECT), which allows material-based differential X-ray absorption behavior from near simultaneously acquired low- and high-kilovolt datasets is finding increasing applications in the evaluation of bowel diseases. In patients with inflammatory bowel disease, DECT techniques permit both qualitative and quantitative assessment. Particularly in patients with Crohn's disease, monoenergetic and iodine specific images have been explored. This article focuses on the principles and applications of DECT in inflammatory bowel disease along with review of its limitations and challenges.
Collapse
Affiliation(s)
- Ramandeep Singh
- Department of Radiology, Massachusetts General Hospital, Boston, MA
| | - Rubal Rai
- Department of Radiology, Massachusetts General Hospital, Boston, MA
| | - Nayla Mroueh
- Department of Radiology, Massachusetts General Hospital, Boston, MA
| | | |
Collapse
|
21
|
Santos Armentia E, Martín Noguerol T, Silva Priegue N, Delgado Sánchez-Gracián C, Trinidad López C, Prada González R. Strengths, weaknesses, opportunities, and threat analysis of dual-energy CT in head and neck imaging. RADIOLOGIA 2022; 64:333-347. [DOI: 10.1016/j.rxeng.2022.05.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2022] [Accepted: 05/19/2022] [Indexed: 11/29/2022]
|
22
|
Santos Armentia E, Martín-Noguerol T, Silva Priegue N, Delgado Sánchez-Gracián C, Trinidad López C, Prada González R. Análisis de las fortalezas, oportunidades, debilidades y amenazas de la tomografía computarizada de doble energía en el diagnóstico por la imagen de la cabeza y el cuello. RADIOLOGIA 2022. [DOI: 10.1016/j.rx.2022.05.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
23
|
Lennartz S, Hokamp NG, Kambadakone A. Dual-Energy CT of the Abdomen: Radiology In Training. Radiology 2022; 305:19-27. [PMID: 35727149 DOI: 10.1148/radiol.212914] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
A 61-year-old man with an esophageal cancer diagnosis underwent staging dual-energy CT of the chest and abdomen in the portal venous phase after contrast media administration. Aside from the primary tumor and suspicious local lymph nodes, CT revealed hypoattenuating ambiguous liver lesions, an incidental right adrenal nodule, and a right renal lesion with soft-tissue attenuation. In addition, advanced atherosclerosis of the abdominal aorta and its major branches was noted. This article provides a case-based review of dual-energy CT technologies and their applications in the abdomen. The clinical utility of virtual monoenergetic images, virtual unenhanced images, and iodine maps is discussed.
Collapse
Affiliation(s)
- Simon Lennartz
- From the Institute for Diagnostic and Interventional Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Kerpener Strasse 62, 50937 Cologne, Germany (S.L., N.G.H.); and Department of Radiology, Division of Abdominal Imaging, Massachusetts General Hospital, Boston, Mass (A.K.)
| | - Nils Große Hokamp
- From the Institute for Diagnostic and Interventional Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Kerpener Strasse 62, 50937 Cologne, Germany (S.L., N.G.H.); and Department of Radiology, Division of Abdominal Imaging, Massachusetts General Hospital, Boston, Mass (A.K.)
| | - Avinash Kambadakone
- From the Institute for Diagnostic and Interventional Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Kerpener Strasse 62, 50937 Cologne, Germany (S.L., N.G.H.); and Department of Radiology, Division of Abdominal Imaging, Massachusetts General Hospital, Boston, Mass (A.K.)
| |
Collapse
|
24
|
Ding Y, Meyer M, Lyu P, Rigiroli F, Ramirez-Giraldo JC, Lafata K, Yang S, Marin D. Can radiomic analysis of a single-phase dual-energy CT improve the diagnostic accuracy of differentiating enhancing from non-enhancing small renal lesions? Acta Radiol 2022; 63:828-838. [PMID: 33878931 DOI: 10.1177/02841851211010396] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND The value of dual-energy computed tomography (DECT)-based radiomics in renal lesions is unknown. PURPOSE To develop DECT-based radiomic models and assess their incremental values in comparison to conventional measurements for differentiating enhancing from non-enhancing small renal lesions. MATERIAL AND METHODS A total of 349 patients with 519 small renal lesions (390 non-enhancing, 129 enhancing) who underwent contrast-enhanced nephrographic phase DECT examinations between June 2013 and January 2020 on multiple DECT platforms were retrospectively recruited. Cohort A included all lesions, while cohort B included Bosniak II-IV and solid enhancing renal lesions. Radiomic models were built with features selected by the least absolute shrinkage and selection operator regression (LASSO). ROC analyses were performed to compare the diagnostic accuracy among conventional and radiomic models for predicting enhancing renal lesions. RESULTS The individual iodine concentration (IC), normalized IC, mean attenuation on 75-keV images, radiomic model of iodine images, 75-keV images and a combined model integrating all the above-mentioned features all demonstrated high AUCs for predicting renal lesion enhancement in cohort A (AUCs = 0.934-0.979) as well as in the test dataset (AUCs = 0.892-0.962) of cohort B (P values with Bonferroni correction >0.003). The AUC (0.864) of mean attenuation on 75-keV images was significantly lower than those of other models (all P values ≤0.001) except the radiomic model of 75-keV images (P = 0.038) in the training dataset of cohort B. CONCLUSION No incremental value was found by adding radiomic and machine learning analyses to iodine images for differentiating enhancing from non-enhancing renal lesions.
Collapse
Affiliation(s)
- Yuqin Ding
- Department of Radiology, Duke University Medical Center, Durham, NC, USA
- Department of Radiology, Zhongshan Hospital, Fudan University; Shanghai Institute of Medical Imaging, Shanghai, PR China
| | - Mathias Meyer
- Department of Radiology, Duke University Medical Center, Durham, NC, USA
| | - Peijie Lyu
- Department of Radiology, Duke University Medical Center, Durham, NC, USA
- Department of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan Province, PR China
| | - Francesca Rigiroli
- Department of Radiology, Duke University Medical Center, Durham, NC, USA
| | | | - Kyle Lafata
- Department of Radiology, Duke University Medical Center, Durham, NC, USA
- Department of Radiation Oncology, Duke University Medical Center, Durham, NC, USA
| | - Siyun Yang
- Department of Biostatistics and Bioinformatics, Duke University School of Medicine, Durham, NC, USA
| | - Daniele Marin
- Department of Radiology, Duke University Medical Center, Durham, NC, USA
| |
Collapse
|
25
|
Prognostic Utility of Parameters Derived From Pretreatment Dual-Layer Spectral-Detector CT in Patients With Metastatic Renal Cell Carcinoma. AJR Am J Roentgenol 2021; 218:867-876. [PMID: 34910540 DOI: 10.2214/ajr.21.26911] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Background: New therapies have emerged for metastatic renal cell carcinoma (mRCC), though corresponding imaging markers are lacking. Dual-layer spectral-detector CT (DLCT) can quantify iodine concentration (IC) and effective atomic number (Zeffective), providing information beyond attenuation that may indicate mRCC prognosis. Objective: To assess the utility of the DLCT-derived parameters IC and Zeffective for predicting mRCC treatment response and survival. Methods: This prospective study (ClinicalTrials.gov identifier: NCT03616951) enrolled 120 participants with mRCC from January 2018 to January 2020 who underwent DLCT before treatment initiation, with reconstruction of IC and Zeffective maps. Final analysis included 115 participants (86 men, 29 women; median age, 65.1 years), incorporating 313 target lesions that were clinically selected using RECIST version 1.1 on arterial-phase acquisitions of the chest and abdomen. Semiautomatic volumetric segmentation was performed of the target lesions. Pixels from all lesions were combined to a single histogram per patient. Median IC and Zeffective of the combined histograms were recorded. Measurements above and below the cohort median values were considered high and low, respectively. Univariable associations were explored between IC and Zeffective, with objective response rate (ORR), progression-free survival (PFS), and overall survival (OS). Multivariable associations were explored between IC and ORR, PFS, and OS, adjusting for treatment (tyrosine kinase inhibitor versus checkpoint immunotherapy) and significant univariable predictors [including tumor histology and International mRCC Database Consortium (IMDC) risk factors]. Results: At baseline, median IC was 2.26 mg/ml, and median Zeffective was 8.49. In univariable analysis, high IC and high Zeffective were associated with better ORR (both OR=4.35, p=.001), better PFS (both HR=0.51, p=.004), and better OS (both HR=0.38, p<.001). In multivariable models, high IC independently predicted better ORR (OR=4.35, p=.001), better PFS (HR=0.51, p=.004), and better OS (HR=0.37, p<.001); neutrophilia independently predicted worse PFS (HR=2.10, p=.004) and worse OS (HR=2.28, p=.003). The estimated c-index for predicting OS using IMDC risk factors was 0.650, versus 0.687 when incorporating high attention and 0.692 when incorporating high IC or high Zeffective. Conclusions: High IC and high Zeffective are significant predictors of better treatment response and survival in mRCC. Clinical impact: Baseline DLCT parameters may improve current mRCC prognostic models.
Collapse
|
26
|
Cano Alonso R, Álvarez Vázquez A, Andreu Vázquez C, Thuissard Vasallo I, Fernández Alfonso A, Recio Rodríguez M, Martínez de Vega V. Tomografía computarizada con energía espectral en la diferenciación de los adenomas y metástasis suprarrenales: utilidad de los mapas de descomposición de materiales y de imágenes monocromáticas. RADIOLOGIA 2021. [DOI: 10.1016/j.rx.2021.10.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
27
|
A Method for Reducing Variability Across Dual-Energy CT Manufacturers in Quantification of Low Iodine Content Levels. AJR Am J Roentgenol 2021; 218:746-755. [PMID: 34668387 DOI: 10.2214/ajr.21.26714] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Background: Clinical use of the dual-energy CT (DECT) iodine quantification technique is hindered by between-platform (i.e., across different manufacturers) variability in iodine concentration (IC), particularly at low iodine levels. Objective: To develop in an anthropomorphic phantom a method for reducing between-platform variability in quantification of low iodine content levels using DECT and to evaluate the method's performance in patients undergoing serial clinical DECT examinations on different platforms. Methods: An anthropomorphic phantom in three body sizes, incorporating varied lesion types and scanning conditions, was imaged with three distinct DECT implementations from different manufacturers at varying radiation exposures. A cross-platform iodine quantification model for correcting between-platform variability at low iodine content was developed using the phantom data. The model was tested in a retrospective series of 30 patients (20 men, 10 women; median age, 62 years) who each underwent three serial contrast-enhanced DECT examinations of the abdomen and pelvis (90 scans total) for routine oncology surveillance, using the same three DECT platforms as in the phantom. Estimated accuracy of phantom IC values was summarized using rootmean-squared error (RMSE) relative to known IC. Between-platform variability in patients was summarized using root-mean-square-deviation (RMSD). RMSE and RMSD were compared between platform-based IC (ICPB) and cross-platform IC (ICCP). ICPB was normalized to aorta and portal vein. Results: In the phantom study, mean RMSE of ICPB across platforms and other experimental conditions was 0.65 ± 0.18 mgI/mL compared with 0.40 ± 0.075 mgI/mL for ICCP (38% decrease in mean RMSE; P<.05). Intra-patient between-platform variability across serial DECT examinations was lower for ICPB than ICCP (RMSD: 97% vs 88%; P<.001). Between-platform variability was not reduced by normalization of ICPB to aorta (RMSD: 97% vs 101%; P=.12) or portal vein (RMSD: 97% vs 97%; P=.81). Conclusion: The developed cross-platform method significantly decreased between-platform variability occurring at low iodine content with platform-based DECT iodine quantification. Clinical Impact: With further validation, the cross-platform method, which has been implemented as a webbased app, may expand clinical use of DECT iodine quantification, yielding meaningful IC values that reflect tissue biologic viability or treatment response in patients who undergo serial examinations on different platforms.
Collapse
|
28
|
Adam SZ, Rabinowich A, Kessner R, Blachar A. Spectral CT of the abdomen: Where are we now? Insights Imaging 2021; 12:138. [PMID: 34580788 PMCID: PMC8476679 DOI: 10.1186/s13244-021-01082-7] [Citation(s) in RCA: 30] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2021] [Accepted: 08/16/2021] [Indexed: 12/14/2022] Open
Abstract
Spectral CT adds a new dimension to radiological evaluation, beyond assessment of anatomical abnormalities. Spectral data allows for detection of specific materials, improves image quality while at the same time reducing radiation doses and contrast media doses, and decreases the need for follow up evaluation of indeterminate lesions. We review the different acquisition techniques of spectral images, mainly dual-source, rapid kV switching and dual-layer detector, and discuss the main spectral results available. We also discuss the use of spectral imaging in abdominal pathologies, emphasizing the strengths and pitfalls of the technique and its main applications in general and in specific organs.
Collapse
Affiliation(s)
- Sharon Z Adam
- Department of Diagnostic Radiology, Tel Aviv Sourasky Medical Center, 6 Weizmann St., 6423906, Tel Aviv, Israel. .,Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel.
| | - Aviad Rabinowich
- Department of Diagnostic Radiology, Tel Aviv Sourasky Medical Center, 6 Weizmann St., 6423906, Tel Aviv, Israel.,Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Rivka Kessner
- Department of Diagnostic Radiology, Tel Aviv Sourasky Medical Center, 6 Weizmann St., 6423906, Tel Aviv, Israel.,Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Arye Blachar
- Department of Diagnostic Radiology, Tel Aviv Sourasky Medical Center, 6 Weizmann St., 6423906, Tel Aviv, Israel.,Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel
| |
Collapse
|
29
|
Green CA, Solomon JB, Ruchala KJ, Samei E. Design and implementation of a practical quality control program for dual-energy CT. J Appl Clin Med Phys 2021; 22:249-260. [PMID: 34472700 PMCID: PMC8504583 DOI: 10.1002/acm2.13396] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2021] [Revised: 07/10/2021] [Accepted: 07/16/2021] [Indexed: 12/16/2022] Open
Abstract
A novel routine dual‐energy computed tomography (DECT) quality control (QC) program was developed to address the current deficiency of routine QC for this technology. The dual‐energy quality control (DEQC) program features (1) a practical phantom with clinically relevant materials and concentrations, (2) a clinically relevant acquisition, reconstruction, and postprocessing protocol, and (3) a fully automated analysis software to extract quantitative data for database storage and trend analysis. The phantom, designed for easy set up for standalone or adjacent imaging next to the ACR phantom, was made in collaboration with an industry partner and informed by clinical needs to have four iodine inserts (0.5, 1, 2, and 5 mg/ml) and one calcium insert (100 mg/ml) equally spaced in a cylindrical water‐equivalent background. The imaging protocol was based on a clinical DECT abdominal protocol capable of producing material specific concentration maps, virtual unenhanced images, and virtual monochromatic images. The QC automated analysis software uses open‐source technologies which integrates well with our current automated CT QC database. The QC program was tested on a GE 750 HD scanner and two Siemens SOMATOM FLASH scanners over a 3‐month period. The automated algorithm correctly identified the appropriate region of interest (ROI) locations and stores measured values in a database for monitoring and trend analysis. Slight variations in protocol settings were noted based on manufacturer. Overall, the project proved to provide a convenient and dependable clinical tool for routine oversight of DE CT imaging within the clinic.
Collapse
Affiliation(s)
- Crystal A Green
- Department of Radiology, Clinical Imaging Physics Group, Duke University Medical Center, Durham, North Carolina, USA
| | - Justin B Solomon
- Clinical Imaging Physics Group, Carl E. Ravin Advanced Imaging Laboratories, Duke University Medical Center, Durham, North Carolina, USA
| | | | - Ehsan Samei
- Department of Radiology, Clinical Imaging Physics Group, Carl E. Ravin Advanced Imaging Laboratories, Duke University Medical Center, Durham, North Carolina, USA
| |
Collapse
|
30
|
Mastrodicasa D, Willemink MJ, Madhuripan N, Chima RS, Ho AA, Ding Y, Marin D, Patel BN. Diagnostic performance of single-phase dual-energy CT to differentiate vascular and nonvascular incidental renal lesions on portal venous phase: comparison with CT. Eur Radiol 2021; 31:9600-9611. [PMID: 34114058 DOI: 10.1007/s00330-021-08097-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2021] [Revised: 05/13/2021] [Accepted: 05/25/2021] [Indexed: 01/14/2023]
Abstract
OBJECTIVES To determine whether single-phase dual-energy CT (DECT) differentiates vascular and nonvascular renal lesions in the portal venous phase (PVP). Optimal iodine threshold was determined and compared to Hounsfield unit (HU) measurements. METHODS We retrospectively included 250 patients (266 renal lesions) who underwent a clinically indicated PVP abdominopelvic CT on a rapid-kilovoltage-switching single-source DECT (rsDECT) or a dual-source DECT (dsDECT) scanner. Iodine concentration and HU measurements were calculated by four experienced readers. Diagnostic accuracy was determined using biopsy results and follow-up imaging as reference standard. Area under the curve (AUC) was calculated for each DECT scanner to differentiate vascular from nonvascular lesions and vascular lesions from hemorrhagic/proteinaceous cysts. Univariable and multivariable logistic regression analyses evaluated the association between variables and the presence of vascular lesions. RESULTS A normalized iodine concentration threshold of 0.25 mg/mL yielded high accuracy in differentiating vascular and nonvascular lesions (AUC 0.93, p < 0.001), with comparable performance to HU measurements (AUC 0.93). Both iodine concentration and HU measurements were independently associated with vascular lesions when adjusted for age, gender, body mass index, and lesion size (AUC 0.95 and 0.95, respectively). When combined, diagnostic performance was higher (AUC 0.96). Both absolute and normalized iodine concentrations performed better than HU measurements (AUC 0.92 vs. AUC 0.87) in differentiating vascular lesions from hemorrhagic/proteinaceous cysts. CONCLUSION A single-phase (PVP) DECT scan yields high accuracy to differentiate vascular from nonvascular renal lesions. Iodine concentration showed a slightly higher performance than HU measurements in differentiating vascular lesions from hemorrhagic/proteinaceous cysts. KEY POINTS • A single-phase dual-energy CT scan in the portal venous phase differentiates vascular from nonvascular renal lesions with high accuracy (AUC 0.93). • When combined, iodine concentration and HU measurements showed the highest diagnostic performance (AUC 0.96) to differentiate vascular from nonvascular renal lesions. • Compared to HU measurements, iodine concentration showed a slightly higher performance in differentiating vascular lesions from hemorrhagic/proteinaceous cysts.
Collapse
Affiliation(s)
- Domenico Mastrodicasa
- Department of Radiology, Stanford University School of Medicine, 300 Pasteur Dr, Stanford, CA, 94305, USA
| | - Martin J Willemink
- Department of Radiology, Stanford University School of Medicine, 300 Pasteur Dr, Stanford, CA, 94305, USA
| | - Nikhil Madhuripan
- Department of Radiology, Stanford University School of Medicine, 300 Pasteur Dr, Stanford, CA, 94305, USA.,Department of Radiology, University of Colorado, 12401 East 17th Avenue, Aurora, CO, 80045, USA
| | - Ranjit Singh Chima
- Department of Radiology, Stanford University School of Medicine, 300 Pasteur Dr, Stanford, CA, 94305, USA
| | - Amanzo A Ho
- Department of Radiology, Stanford University School of Medicine, 300 Pasteur Dr, Stanford, CA, 94305, USA
| | - Yuqin Ding
- Department of Radiology, Duke University Medical Center, 2301 Erwin Rd, Durham, NC, 27710, USA.,Department of Radiology, Zhongshan Hospital, Fudan University; Shanghai Institute of Medical Imaging, Shanghai, 200032, People's Republic of China
| | - Daniele Marin
- Department of Radiology, Duke University Medical Center, 2301 Erwin Rd, Durham, NC, 27710, USA
| | - Bhavik N Patel
- Department of Radiology, Mayo Clinic, 13400 E Shea Blvd, Scottsdale, AZ, 85259, USA.
| |
Collapse
|
31
|
Non-invasive assessment of cirrhosis using multiphasic dual-energy CT iodine maps: correlation with model for end-stage liver disease score. Abdom Radiol (NY) 2021; 46:1931-1940. [PMID: 33211150 DOI: 10.1007/s00261-020-02857-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2020] [Revised: 10/29/2020] [Accepted: 11/05/2020] [Indexed: 12/23/2022]
Abstract
PURPOSE To determine whether multiphasic dual-energy (DE) CT iodine quantitation correlates with the severity of chronic liver disease. METHODS We retrospectively included 40 cirrhotic and 28 non-cirrhotic patients who underwent a multiphasic liver protocol DECT. All three phases (arterial, portal venous (PVP), and equilibrium) were performed in DE mode. Iodine (I) values (mg I/ml) were obtained by placing regions of interest in the liver, aorta, common hepatic artery, and portal vein (PV). Iodine slopes (λ) were calculated as follows: (Iequilibrium-Iarterial)/time and (Iequilibrium-IPVP)/time. Spearman correlations between λ and MELD scores were evaluated, and the area under the curve of the receiver operating characteristic (AUROC) was calculated to distinguish cirrhotic and non-cirrhotic patients. RESULTS Cirrhotic and non-cirrhotic patients had significantly different λequilibrium-arterial [IQR] for the caudate (λ = 2.08 [1.39-2.98] vs 1.46 [0.76-1.93], P = 0.007), left (λ = 2.05 [1.50-2.76] vs 1.51 [0.59-1.90], P = 0.002) and right lobes (λ = 1.72 [1.12-2.50] vs 1.13 [0.41-0.43], P = 0.003) and for the PV (λ = 3.15 [2.20-5.00] vs 2.29 [0.85-2.71], P = 0.001). λequilibrium-PVP were significantly different for the right (λ = 0.11 [- 0.45-1.03] vs - 0.44 [- 0.83-0.12], P = 0.045) and left lobe (λ = 0.30 [- 0.25-0.98] vs - 0.10 [- 0.35-0.24], P = 0.001). Significant positive correlations were found between MELD scores and λequilibrium-arterial for the caudate lobe (ρ = 0.34, P = 0.004) and λequilibrium-PVP for the caudate (ρ = 0.26, P = 0.028) and right lobe (ρ = 0.33, P = 0.007). AUROC in distinguishing cirrhotic and non-cirrhotic patients were 0.72 (P = 0.002), 0.71 (P = 0.003), and 0.75 (P = 0.001) using λequilibrium-arterial for the left lobe, right lobe, and PV, respectively. The λequilibrium-PVP AUROC of the right lobe was 0.73 (P = 0.001). CONCLUSION Multiphasic DECT iodine quantitation over time is significantly different between cirrhotic and non-cirrhotic patients, correlates with the MELD score, and it could potentially serve as a non-invasive measure of cirrhosis and disease severity with acceptable diagnostic accuracy.
Collapse
|
32
|
Investigating new CT contrast agents: a phantom study exploring quantification and differentiation methods for high-Z elements using dual-energy CT. Eur Radiol 2021; 31:8060-8067. [PMID: 33856524 DOI: 10.1007/s00330-021-07886-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2020] [Revised: 03/05/2021] [Accepted: 03/15/2021] [Indexed: 12/31/2022]
Abstract
OBJECTIVES To develop a dual-energy CT method for differentiating and quantifying high-Z contrast elements and to evaluate the limitations based on element concentration and atomic number by using an anthropomorphic phantom study. METHODS Mass spectrometry standards for iodine, barium, gadolinium, ytterbium, tantalum, gold, and bismuth were diluted from 10.0 to 0.3 mg/mL, placed inside 7-mL vials, and scanned with dual-energy CT using an abdominal phantom and cylindrical water-filled insert. This procedure was repeated with all seven high-Z elements at six isoattenuating values from 250 to 8 HU. Quantification accuracy was measured using a linear regression model and residual error analysis with 90% limits of agreement. The limit of detection for each element was evaluated using the limit of blank of water. Pairwise differentiation of isoattenuating vials was evaluated using AUC values and the difference in fit angles between the two elements. RESULTS Each high-Z element had a unique concentration vector in a two-dimensional plot of Compton scattering versus photoelectric effect attenuations. Mean quantification values were within ± 0.1 mg/mL of the true values for each element with no proportional bias. Limits of detection ranged from 0.35 to 0.56 mg/mL. Pairwise differentiations were proportional to the isoattenuating HU and the angle between the linear fits with mean AUC values increasing from 0.61 to 0.98 at 8 to 250 HU, respectively. CONCLUSION Dual-energy CT can differentiate and quantify isoattenuating high-Z elements. The high-attenuation characteristics and unique concentration vectors of ytterbium, tantalum, gold, and bismuth are well suited for new dual-energy CT contrast agents especially when simultaneously imaged with iodine, barium, or gadolinium. KEY POINTS • Dual-energy CT can accurately quantify high-Z contrast elements and readily differentiate iodine, barium, and gadolinium from ytterbium, tantalum, gold, and bismuth. • The differentiation and quantification capabilities for high-Z contrast elements are largely unaffected by phantom size and transaxial location within the phantom. • Potential benefits of new CT contrast agents based on these high-Z elements include alternatives for patients with iodine sensitivity, high conspicuity at both 120 and 140 kVp, simultaneous imaging of two contrast agents, and reduced injection volume.
Collapse
|
33
|
Zopfs D, Reimer RP, Sonnabend K, Rinneburger M, Hentschke CM, Persigehl T, Lennartz S, Große Hokamp N. Intraindividual Consistency of Iodine Concentration in Dual-Energy Computed Tomography of the Chest and Abdomen. Invest Radiol 2021; 56:181-187. [PMID: 32932376 DOI: 10.1097/rli.0000000000000724] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
OBJECTIVES Dual-energy computed tomography (DECT)-derived quantification of iodine concentration (IC) is increasingly used in oncologic imaging to characterize lesions and evaluate treatment response. However, only limited data are available on intraindividual consistency of IC and its variation. This study investigates the longitudinal reproducibility of IC in organs, vessels, and lymph nodes in a large cohort of healthy patients who underwent repetitive DECT imaging. MATERIALS AND METHODS A total of 159 patients, who underwent a total of 469 repetitive (range, 2-4), clinically indicated portal-venous phase DECT examinations of the chest and abdomen, were retrospectively included. At time of imaging, macroscopic tumor burden was excluded by follow-up imaging (≥3 months). Iodine concentration was measured region of interest-based (N = 43) in parenchymatous organs, vessels, lymph nodes, and connective tissue. Normalization of IC to the aorta and to the trigger delay as obtained from bolus tracking was performed. For statistical analysis, intraclass correlation coefficient and modified variation coefficient (MVC) were used to assess intraindividual agreement of IC and its variation between different time points, respectively. Furthermore, t tests and analysis of variance with Tukey-Kramer post hoc test were used. RESULTS The mean intraclass correlation coefficient over all regions of interest was good to excellent (0.642-0.936), irrespective of application of normalization or the normalization technique. Overall, MVC ranged from 1.8% to 25.4%, with significantly lower MVC in data normalized to the aorta (5.8% [1.8%-15.8%]) in comparison with the MVC of not normalized data and data normalized to the trigger delay (P < 0.01 and P = 0.04, respectively). CONCLUSIONS Our study confirms intraindividual, longitudinal variation of DECT-derived IC, which varies among vessels, lymph nodes, organs, and connective tissue, following different perfusion characteristics; normalizing to the aorta seems to improve reproducibility when using a constant contrast media injection protocol.
Collapse
Affiliation(s)
- David Zopfs
- From the Faculty of Medicine, University Cologne, and Institute for Diagnostic and Interventional Radiology, University Hospital Cologne, Germany
| | - Robert Peter Reimer
- From the Faculty of Medicine, University Cologne, and Institute for Diagnostic and Interventional Radiology, University Hospital Cologne, Germany
| | - Kristina Sonnabend
- From the Faculty of Medicine, University Cologne, and Institute for Diagnostic and Interventional Radiology, University Hospital Cologne, Germany
| | - Miriam Rinneburger
- From the Faculty of Medicine, University Cologne, and Institute for Diagnostic and Interventional Radiology, University Hospital Cologne, Germany
| | | | - Thorsten Persigehl
- From the Faculty of Medicine, University Cologne, and Institute for Diagnostic and Interventional Radiology, University Hospital Cologne, Germany
| | | | - Nils Große Hokamp
- From the Faculty of Medicine, University Cologne, and Institute for Diagnostic and Interventional Radiology, University Hospital Cologne, Germany
| |
Collapse
|
34
|
Kupik O, Metin Y, Eren G, Orhan Metin N, Arpa M. A comparison study of dual-energy spectral CT and 18F-FDG PET/CT in primary tumors and lymph nodes of lung cancer. ACTA ACUST UNITED AC 2021; 27:275-282. [PMID: 33455897 DOI: 10.5152/dir.2021.20016] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
Abstract
PURPOSE We aimed to investigate whether there is a correlation between dual-energy spectral computed tomography (DESCT) and 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) parameters in primary tumor and metastatic lymph nodes in patients with newly diagnosed lung cancer. METHODS Primary tumor and metastatic lymph nodes of 68 patients diagnosed with lung cancer were evaluated retrospectively with 18F-FDG PET/CT and DESCT imaging. The histologic subtypes were adenocarcinoma (n=29), squamous cell carcinoma (SCC) (n=26), small cell lung cancer (SCLC) (n=11), and large cell neuroendocrine cancer (LCNEC) (n=2). In terms of PET parameters, SUVmax, SUVmean, SULmax, SULmean, SULpeak, and normalized SUL values were obtained for primary tumors and metastatic lymph nodes. In terms of DESCT parameters, maximum and mean iodine content (IC), normalized IC values, iodine enhancement (IE) and normalized IE values were calculated. RESULTS We found no correlation between DESCT and 18F-FDG PET/CT parameters in primary tumors and metastatic lymph nodes. In addition, no correlation was found in the analysis performed in any of the histologic subgroups. In patients with a primary tumor <3 cm, there was a moderate negative correlation between the parameters SUVmax-ICmax (r= -0.456, p = 0.043), SUVmean-ICmax (r= -0.464, p = 0.039) SULmean-ICmax (r= -0.497, p = 0.026), SUVmax-ICmean (r= -0.527, p = 0.020), SULmean-ICmean (r= -0.499, p = 0.025), and SULpeak-ICmean (r= -0.488, p = 0.029). CONCLUSION We consider that DESCT and 18F-FDG PET/CT indicate different characteristics of the tumors and should not supersede each other.
Collapse
Affiliation(s)
- Osman Kupik
- Department of Nuclear Medicine Recep Tayyip Erdoğan University School of Medicine, Rize, Turkey
| | - Yavuz Metin
- Department of Radiology, Ankara University School of Medicine, Ibni Sina Hospital, Ankara, Turkey
| | - Gülnihan Eren
- Department of Radiation Oncology, Recep Tayyip Erdoğan University School of Medicine, Rize, Turkey
| | - Nurgul Orhan Metin
- Department of Radiology, Recep Tayyip Erdoğan University School of Medicine, Rize, Turkey
| | - Medeni Arpa
- Department of Biochemistry, Recep Tayyip Erdoğan University School of Medicine, Rize, Turkey
| |
Collapse
|
35
|
Xiao JM, Hippe DS, Zecevic M, Zamora DA, Cai LM, Toia GV, Chandler AG, Dighe MK, O'Malley RB, Shuman WP, Wang CL, Mileto A. Virtual Unenhanced Dual-Energy CT Images Obtained with a Multimaterial Decomposition Algorithm: Diagnostic Value for Renal Mass and Urinary Stone Evaluation. Radiology 2021; 298:611-619. [PMID: 33464180 DOI: 10.1148/radiol.2021192448] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
Abstract
Background Virtual unenhanced (VUE) images obtained by using a dual-energy CT (DECT) multimaterial decomposition algorithm hold promise for diagnostic use in the abdomen in lieu of true unenhanced (TUE) images. Purpose To assess VUE images obtained from a DECT multimaterial decomposition algorithm in patients undergoing renal mass and urinary stone evaluation. Materials and Methods In this retrospective Health Insurance Portability and Accountability Act-compliant study, DECT was performed in patients undergoing evaluation for renal mass or urinary stone. VUE images were compared quantitatively to TUE images and qualitatively assessed by four independent radiologists. Differences in attenuation between VUE and TUE images were summarized by using 95% limits of agreement. Diagnostic performance in urinary stone detection was summarized by using area under the receiver operating characteristic curve, sensitivity, and specificity. Results A total of 221 patients (mean age ± standard deviation, 61 years ± 14; 129 men) with 273 renal masses were evaluated. Differences in renal mass attenuation between VUE and TUE images were within 3 HU for both enhancing masses (95% limits of agreement, -3.1 HU to 2.7 HU) and nonenhancing cysts (95% limits of agreement, -2.9 HU to 2.5 HU). Renal mass classification as enhancing mass versus nonenhancing cyst did not change (reclassification rate of enhancing masses, 0% [0 of 78]; 95% CI: 0, 5; reclassification rate of nonenhancing cysts, 0% [0 of 193]; 95% CI: 0, 2) with use of VUE in lieu of TUE images. Among 166 urinary stones evaluated, diagnostic performance of VUE images for stone detection was lower compared with that of TUE images (area under the receiver operating characteristic curve, 0.79 [95% CI: 0.73, 0.84] vs 0.93 [95% CI: 0.91, 0.95]; P < .001) due to reduced sensitivity of VUE for detection of stones 3 mm in diameter or less compared with those greater than 3 mm (sensitivity, 23% [25 of 108; 95% CI: 12, 40] vs 88% [126 of 144; 95% CI: 77, 94]; P < .001). Conclusion Compared with true unenhanced images, virtual unenhanced (VUE) images were unlikely to change renal mass classification as enhancing mass versus nonenhancing cyst. Diagnostic performance of VUE images remained suboptimal for urinary stone detection due to subtraction of stones 3 mm or less in diameter. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Sosna in this issue.
Collapse
Affiliation(s)
- Jennifer M Xiao
- From the Department of Radiology, University of Washington School of Medicine, Box 357115, 1959 NE Pacific St, Seattle, WA 98195 (J.M.X., D.S.H., M.Z., D.A.Z., L.M.C., G.V.T., M.K.D., R.B.O., W.P.S., C.L.W., A.M.); and Global Research Organization, GE Healthcare, Houston, Tex (A.G.C.)
| | - Daniel S Hippe
- From the Department of Radiology, University of Washington School of Medicine, Box 357115, 1959 NE Pacific St, Seattle, WA 98195 (J.M.X., D.S.H., M.Z., D.A.Z., L.M.C., G.V.T., M.K.D., R.B.O., W.P.S., C.L.W., A.M.); and Global Research Organization, GE Healthcare, Houston, Tex (A.G.C.)
| | - Mladen Zecevic
- From the Department of Radiology, University of Washington School of Medicine, Box 357115, 1959 NE Pacific St, Seattle, WA 98195 (J.M.X., D.S.H., M.Z., D.A.Z., L.M.C., G.V.T., M.K.D., R.B.O., W.P.S., C.L.W., A.M.); and Global Research Organization, GE Healthcare, Houston, Tex (A.G.C.)
| | - David A Zamora
- From the Department of Radiology, University of Washington School of Medicine, Box 357115, 1959 NE Pacific St, Seattle, WA 98195 (J.M.X., D.S.H., M.Z., D.A.Z., L.M.C., G.V.T., M.K.D., R.B.O., W.P.S., C.L.W., A.M.); and Global Research Organization, GE Healthcare, Houston, Tex (A.G.C.)
| | - Larry M Cai
- From the Department of Radiology, University of Washington School of Medicine, Box 357115, 1959 NE Pacific St, Seattle, WA 98195 (J.M.X., D.S.H., M.Z., D.A.Z., L.M.C., G.V.T., M.K.D., R.B.O., W.P.S., C.L.W., A.M.); and Global Research Organization, GE Healthcare, Houston, Tex (A.G.C.)
| | - Giuseppe V Toia
- From the Department of Radiology, University of Washington School of Medicine, Box 357115, 1959 NE Pacific St, Seattle, WA 98195 (J.M.X., D.S.H., M.Z., D.A.Z., L.M.C., G.V.T., M.K.D., R.B.O., W.P.S., C.L.W., A.M.); and Global Research Organization, GE Healthcare, Houston, Tex (A.G.C.)
| | - Adam G Chandler
- From the Department of Radiology, University of Washington School of Medicine, Box 357115, 1959 NE Pacific St, Seattle, WA 98195 (J.M.X., D.S.H., M.Z., D.A.Z., L.M.C., G.V.T., M.K.D., R.B.O., W.P.S., C.L.W., A.M.); and Global Research Organization, GE Healthcare, Houston, Tex (A.G.C.)
| | - Manjiri K Dighe
- From the Department of Radiology, University of Washington School of Medicine, Box 357115, 1959 NE Pacific St, Seattle, WA 98195 (J.M.X., D.S.H., M.Z., D.A.Z., L.M.C., G.V.T., M.K.D., R.B.O., W.P.S., C.L.W., A.M.); and Global Research Organization, GE Healthcare, Houston, Tex (A.G.C.)
| | - Ryan B O'Malley
- From the Department of Radiology, University of Washington School of Medicine, Box 357115, 1959 NE Pacific St, Seattle, WA 98195 (J.M.X., D.S.H., M.Z., D.A.Z., L.M.C., G.V.T., M.K.D., R.B.O., W.P.S., C.L.W., A.M.); and Global Research Organization, GE Healthcare, Houston, Tex (A.G.C.)
| | - William P Shuman
- From the Department of Radiology, University of Washington School of Medicine, Box 357115, 1959 NE Pacific St, Seattle, WA 98195 (J.M.X., D.S.H., M.Z., D.A.Z., L.M.C., G.V.T., M.K.D., R.B.O., W.P.S., C.L.W., A.M.); and Global Research Organization, GE Healthcare, Houston, Tex (A.G.C.)
| | - Carolyn L Wang
- From the Department of Radiology, University of Washington School of Medicine, Box 357115, 1959 NE Pacific St, Seattle, WA 98195 (J.M.X., D.S.H., M.Z., D.A.Z., L.M.C., G.V.T., M.K.D., R.B.O., W.P.S., C.L.W., A.M.); and Global Research Organization, GE Healthcare, Houston, Tex (A.G.C.)
| | - Achille Mileto
- From the Department of Radiology, University of Washington School of Medicine, Box 357115, 1959 NE Pacific St, Seattle, WA 98195 (J.M.X., D.S.H., M.Z., D.A.Z., L.M.C., G.V.T., M.K.D., R.B.O., W.P.S., C.L.W., A.M.); and Global Research Organization, GE Healthcare, Houston, Tex (A.G.C.)
| |
Collapse
|
36
|
Parakh A, Lennartz S, An C, Rajiah P, Yeh BM, Simeone FJ, Sahani DV, Kambadakone AR. Dual-Energy CT Images: Pearls and Pitfalls. Radiographics 2021; 41:98-119. [PMID: 33411614 PMCID: PMC7853765 DOI: 10.1148/rg.2021200102] [Citation(s) in RCA: 42] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2020] [Revised: 07/10/2020] [Accepted: 07/16/2020] [Indexed: 01/10/2023]
Abstract
Dual-energy CT (DECT) is a tremendous innovation in CT technology that allows creation of numerous imaging datasets by enabling discrete acquisitions at more than one energy level. The wide range of images generated from a single DECT acquisition provides several benefits such as improved lesion detection and characterization, superior determination of material composition, reduction in the dose of iodine, and more robust quantification. Technological advances and the proliferation of various processing methods have led to the availability of diverse vendor-based DECT approaches, each with a different acquisition and image reconstruction process. The images generated from various DECT scanners differ from those from conventional single-energy CT because of differences in their acquisition techniques, material decomposition methods, image reconstruction algorithms, and postprocessing methods. DECT images such as virtual monochromatic images, material density images, and virtual unenhanced images have different imaging appearances, texture features, and quantitative capabilities. This heterogeneity creates challenges in their routine interpretation and has certain associated pitfalls. Some artifacts such as residual iodine on virtual unenhanced images and an appearance of pseudopneumatosis in a gas-distended bowel loop on material-density iodine images are specific to DECT, while others such as pseudoenhancement seen on virtual monochromatic images are also observed at single-energy CT. Recognizing the potential pitfalls associated with DECT is necessary for appropriate and accurate interpretation of the results of this increasingly important imaging tool. Online supplemental material is available for this article. ©RSNA, 2021.
Collapse
Affiliation(s)
- Anushri Parakh
- From the Department of Radiology, Massachusetts General Hospital, 55 Fruit St, White 270, Boston, MA 02114 (A.P., S.L., F.J.S., A.R.K.); Department of Radiology and Biomedical Imaging, University of California–San Francisco, San Francisco, Calif (C.A., B.M.Y.); Department of Radiology, Mayo Clinic, Rochester, Minn (P.R.); Department of Radiology, University of Washington, Seattle, Wash (D.V.S.); and Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany (S.L.)
| | - Simon Lennartz
- From the Department of Radiology, Massachusetts General Hospital, 55 Fruit St, White 270, Boston, MA 02114 (A.P., S.L., F.J.S., A.R.K.); Department of Radiology and Biomedical Imaging, University of California–San Francisco, San Francisco, Calif (C.A., B.M.Y.); Department of Radiology, Mayo Clinic, Rochester, Minn (P.R.); Department of Radiology, University of Washington, Seattle, Wash (D.V.S.); and Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany (S.L.)
| | - Chansik An
- From the Department of Radiology, Massachusetts General Hospital, 55 Fruit St, White 270, Boston, MA 02114 (A.P., S.L., F.J.S., A.R.K.); Department of Radiology and Biomedical Imaging, University of California–San Francisco, San Francisco, Calif (C.A., B.M.Y.); Department of Radiology, Mayo Clinic, Rochester, Minn (P.R.); Department of Radiology, University of Washington, Seattle, Wash (D.V.S.); and Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany (S.L.)
| | - Prabhakar Rajiah
- From the Department of Radiology, Massachusetts General Hospital, 55 Fruit St, White 270, Boston, MA 02114 (A.P., S.L., F.J.S., A.R.K.); Department of Radiology and Biomedical Imaging, University of California–San Francisco, San Francisco, Calif (C.A., B.M.Y.); Department of Radiology, Mayo Clinic, Rochester, Minn (P.R.); Department of Radiology, University of Washington, Seattle, Wash (D.V.S.); and Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany (S.L.)
| | - Benjamin M. Yeh
- From the Department of Radiology, Massachusetts General Hospital, 55 Fruit St, White 270, Boston, MA 02114 (A.P., S.L., F.J.S., A.R.K.); Department of Radiology and Biomedical Imaging, University of California–San Francisco, San Francisco, Calif (C.A., B.M.Y.); Department of Radiology, Mayo Clinic, Rochester, Minn (P.R.); Department of Radiology, University of Washington, Seattle, Wash (D.V.S.); and Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany (S.L.)
| | - Frank J. Simeone
- From the Department of Radiology, Massachusetts General Hospital, 55 Fruit St, White 270, Boston, MA 02114 (A.P., S.L., F.J.S., A.R.K.); Department of Radiology and Biomedical Imaging, University of California–San Francisco, San Francisco, Calif (C.A., B.M.Y.); Department of Radiology, Mayo Clinic, Rochester, Minn (P.R.); Department of Radiology, University of Washington, Seattle, Wash (D.V.S.); and Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany (S.L.)
| | - Dushyant V. Sahani
- From the Department of Radiology, Massachusetts General Hospital, 55 Fruit St, White 270, Boston, MA 02114 (A.P., S.L., F.J.S., A.R.K.); Department of Radiology and Biomedical Imaging, University of California–San Francisco, San Francisco, Calif (C.A., B.M.Y.); Department of Radiology, Mayo Clinic, Rochester, Minn (P.R.); Department of Radiology, University of Washington, Seattle, Wash (D.V.S.); and Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany (S.L.)
| | - Avinash R. Kambadakone
- From the Department of Radiology, Massachusetts General Hospital, 55 Fruit St, White 270, Boston, MA 02114 (A.P., S.L., F.J.S., A.R.K.); Department of Radiology and Biomedical Imaging, University of California–San Francisco, San Francisco, Calif (C.A., B.M.Y.); Department of Radiology, Mayo Clinic, Rochester, Minn (P.R.); Department of Radiology, University of Washington, Seattle, Wash (D.V.S.); and Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany (S.L.)
| |
Collapse
|
37
|
A Universal Protocol for Abdominal CT Examinations Performed on a Photon-Counting Detector CT System: A Feasibility Study. Invest Radiol 2020; 55:226-232. [PMID: 32049691 DOI: 10.1097/rli.0000000000000634] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVE The aims of this study were to investigate the feasibility of using a universal abdominal acquisition protocol on a photon-counting detector computed tomography (PCD-CT) system and to compare its performance to that of single-energy (SE) and dual-energy (DE) CT using energy-integrating detectors (EIDs). METHODS Iodine inserts of various concentrations and sizes were embedded into different sizes of adult abdominal phantoms. Phantoms were scanned on a research PCD-CT and a clinical EID-CT with SE and DE modes. Virtual monoenergetic images (VMIs) were generated from PCD-CT and DE mode of EID-CT. For each image type and phantom size, contrast-to-noise ratio (CNR) was measured for each iodine insert and the area under the receiver operating characteristic curve (AUC) for iodine detectability was calculated using a channelized Hotelling observer. The optimal energy (in kiloelectrovolt) of VMIs was determined separately as the one with highest CNR and the one with the highest AUC. The PCD-CT VMIs at the optimal energy were then compared with DE VMIs and SE images in terms of CNR and AUC. RESULTS Virtual monoenergetic image at 50 keV had both the highest CNR and highest AUC for PCD-CT and DECT. For 1.0 mg I/mL iodine and 35 cm phantom, the CNRs of 50 keV VMIs from PCD-CT (2.01 ± 0.67) and DE (1.96 ± 0.52) were significantly higher (P < 0.001, Wilcoxon signed-rank test) than SE images (1.11 ± 0.35). The AUC of PCD-CT (0.98 ± 0.01) was comparable to SE (0.98 ± 0.01), and both were slightly lower than DE (0.99 ± 0.01, P < 0.01, Wilcoxon signed-rank test). A similar trend was observed for other phantom sizes and iodine concentrations. CONCLUSIONS Virtual monoenergetic images at a fixed energy from a universal acquisition protocol on PCD-CT demonstrated higher iodine CNR and comparable iodine detectability than SECT images, and similar performance compared with DE VMIs.
Collapse
|
38
|
Thiravit S, Brunnquell C, Cai LM, Flemon M, Mileto A. Use of dual-energy CT for renal mass assessment. Eur Radiol 2020; 31:3721-3733. [PMID: 33210200 DOI: 10.1007/s00330-020-07426-z] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2020] [Revised: 08/11/2020] [Accepted: 10/14/2020] [Indexed: 12/22/2022]
Abstract
Although dual-energy CT (DECT) may prove useful in a variety of abdominal imaging tasks, renal mass evaluation represents the area where this technology can be most impactful in abdominal imaging compared to routinely performed contrast-enhanced-only single-energy CT exams. DECT post-processing techniques, such as creation of virtual unenhanced and iodine density images, can help in the characterization of incidentally discovered renal masses that would otherwise remain indeterminate based on post-contrast imaging only. The purpose of this article is to review the use of DECT for renal mass assessment, including its benefits and existing limitations. KEY POINTS: • If DECT is selected as the scanning mode for most common abdominal protocols, many incidentally found renal masses can be fully triaged within the same exam. • Virtual unenhanced and iodine density DECT images can provide additional information when renal masses are discovered in the post-contrast-only setting. • For renal mass evaluation, virtual unenhanced and iodine density DECT images should be interpreted side-by-side to troubleshoot pitfalls that can potentially lead to erroneous interpretation.
Collapse
Affiliation(s)
- Shanigarn Thiravit
- Department of Radiology, University of Washington School of Medicine, 1959 NE Pacific Street, Box 357115, Seattle, WA, 98195, USA.,Division of Diagnostic Radiology, Department of Radiology, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Christina Brunnquell
- Department of Radiology, University of Washington School of Medicine, 1959 NE Pacific Street, Box 357115, Seattle, WA, 98195, USA
| | - Larry M Cai
- Department of Radiology, University of Washington School of Medicine, 1959 NE Pacific Street, Box 357115, Seattle, WA, 98195, USA
| | - Mena Flemon
- Department of Radiology, University of Washington School of Medicine, 1959 NE Pacific Street, Box 357115, Seattle, WA, 98195, USA
| | - Achille Mileto
- Department of Radiology, University of Washington School of Medicine, 1959 NE Pacific Street, Box 357115, Seattle, WA, 98195, USA.
| |
Collapse
|
39
|
Split-Bolus, Single-Acquisition, Dual-Phase Abdominopelvic CT Angiography for the Evaluation of Lung Transplant Candidates: Image Quality and Resource Utilization. AJR Am J Roentgenol 2020; 215:1520-1527. [PMID: 33052735 DOI: 10.2214/ajr.19.22335] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE. The purpose of this study was to assess the image quality and resource utilization of single-injection, split-bolus, dual-enhancement abdominopelvic CT angiography (hereafter referred to as dual-enhancement CTA) performed for combined vascular and solid organ assessment compared with those of single-injection, single-enhancement abdominopelvic CT angiography (hereafter referred to as single-enhancement CTA) for vascular assessment in combination with additional examinations (CT, MRI, and US) performed to assess for malignancy in lung transplant candidates. MATERIALS AND METHODS. We retrospectively reviewed 100 patients who underwent abdominopelvic CTA examinations before lung transplant. Cohort A (n = 50) underwent dual-enhancement CTA and cohort B (n = 50) underwent single-enhancement CTA. Contrast opacification of the vasculature was assessed along the abdominal aorta through the right femoral artery. Solid organ enhancement was assessed in the right lobe of the liver and the right renal cortex. Measurements of mean radiation dose, contrast exposure, and cost of the studies (in U.S. dollars) were compared. RESULTS. Mean (± SD) vascular enhancement on dual-enhancement CTA and single-enhancement CTA was 334.2 ± 26.5 HU (coefficient of variation, 8.3%) and 340.0 ± 21.6 HU (coefficient of variation, 6.5%) (p = 0.23), respectively. For dual-enhancement CTA and single-enhancement CTA, mean liver enhancement was 125.8 ± 30.5 HU and 60.4 ± 6.9 HU (p < 0.01), respectively, whereas mean renal cortical enhancement was 260.3 ± 62.2 HU and 133.4 ± 38.6 HU (p < 0.01), respectively. The mean IV contrast volume was 150 mL for dual-enhancement CTA and 75 mL for single-enhancement CTA. Cohort A underwent six additional imaging studies (one of which was a CT colonography study with an effective dose of 19.0 mSv) at a total cost of $9840 per patient. Cohort B underwent 44 additional imaging studies (mean effective dose, 12.7 ± 6.5 mSv) at a total cost of $12,846 per patient (resulting in a 30.6% reduction in cost for dual-enhancement CTA studies; p < 0.0001). CONCLUSION. Dual-enhancement abdominopelvic CTA allows combined vascular and abdominopelvic solid organ assessment with improved image quality and a lower cost compared with traditional imaging pathways.
Collapse
|
40
|
Normalized Dual-Energy Iodine Ratio Best Differentiates Renal Cell Carcinoma Subtypes Among Quantitative Imaging Biomarkers From Perfusion CT and Dual-Energy CT. AJR Am J Roentgenol 2020; 215:1389-1397. [PMID: 33052738 DOI: 10.2214/ajr.19.22612] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
OBJECTIVE. The objective of our study was to assess and compare the diagnostic accuracy of perfusion CT (PCT) and dual-energy CT (DECT) in differentiating clear cell renal cell carcinoma (ccRCC) from non-ccRCC. MATERIALS AND METHODS. This retrospective study included 51 patients with 52 renal cell carcinomas (RCCs) (36 ccRCCs and 16 non-ccRCCs) who underwent both PCT and DECT before surgery or biopsy between January 2014 and December 2018. Three independent readers measured blood flow, blood volume (BV), and permeability using PCT and iodine concentration (IC) and iodine ratio using DECT. Interreader agreement was calculated using the intraclass correlation coefficient (ICC). Multivariable logistic regression analysis was performed to assess PCT and DECT models. Size-specific dose estimates of the two methods were compared. RESULTS. BV (ICC, 0.93) and iodine ratio (ICC, 0.85) were the most reproducible parameters. Both PCT and DECT were significant models (p < 0.05, all readers) for differentiating ccRCC from non-ccRCC. There was no significant difference in diagnostic accuracy between PCT and DECT (p > 0.05). BV and iodine ratio were independent predictors of nonccRCC (p < 0.05). However, the mean size-specific dose estimate was 16 times lower with DECT than with PCT (p < 0.001). The AUC of iodine ratio was 0.95, and sensitivity, specificity, and accuracy with an iodine ratio cutoff of 63.72% was 0.90, 0.86, and 0.87, respectively. CONCLUSION. PCT and DECT had comparable and high diagnostic accuracy in differentiating RCC subtypes; however, because of the significantly lower radiation dose of DECT, iodine ratio may be used as the best independent predictor.
Collapse
|
41
|
Xu JJ, Taudorf M, Ulriksen PS, Achiam MP, Resch TA, Nielsen MB, Lönn LB, Hansen KL. Gastrointestinal Applications of Iodine Quantification Using Dual-Energy CT: A Systematic Review. Diagnostics (Basel) 2020; 10:diagnostics10100814. [PMID: 33066281 PMCID: PMC7602017 DOI: 10.3390/diagnostics10100814] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2020] [Revised: 10/04/2020] [Accepted: 10/07/2020] [Indexed: 12/15/2022] Open
Abstract
Dual-energy computed tomography (DECT) can estimate tissue vascularity and perfusion via iodine quantification. The aim of this systematic review was to outline current and emerging clinical applications of iodine quantification within the gastrointestinal tract using DECT. The search was conducted with three databases: EMBASE, Pubmed and The Cochrane Library. This identified 449 studies after duplicate removal. From a total of 570 selected studies, 30 studies were enrolled for the systematic review. The studies were categorized into four main topics: gastric tumors (12 studies), colorectal tumors (8 studies), Crohn’s disease (4 studies) and miscellaneous applications (6 studies). Findings included a significant difference in iodine concentration (IC) measurements in perigastric fat between T1–3 vs. T4 stage gastric cancer, poorly and well differentiated gastric and colorectal cancer, responders vs. non-responders following chemo- or chemoradiotherapy treatment among cancer patients, and a positive correlation between IC and Crohn’s disease activity. In conclusion, iodine quantification with DECT may be used preoperatively in cancer imaging as well as for monitoring treatment response. Future studies are warranted to evaluate the capabilities and limitations of DECT in splanchnic flow.
Collapse
Affiliation(s)
- Jack Junchi Xu
- Department of Diagnostic Radiology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark; (M.B.N.); (L.B.L.); (K.L.H.)
- Department of Surgical Gastroenterology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark; (M.T.); (P.S.U.); (M.P.A.); (T.A.R.)
- Correspondence:
| | - Mikkel Taudorf
- Department of Surgical Gastroenterology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark; (M.T.); (P.S.U.); (M.P.A.); (T.A.R.)
| | - Peter Sommer Ulriksen
- Department of Surgical Gastroenterology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark; (M.T.); (P.S.U.); (M.P.A.); (T.A.R.)
| | - Michael Patrick Achiam
- Department of Surgical Gastroenterology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark; (M.T.); (P.S.U.); (M.P.A.); (T.A.R.)
- Department of Vascular Surgery, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark
| | - Timothy Andrew Resch
- Department of Surgical Gastroenterology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark; (M.T.); (P.S.U.); (M.P.A.); (T.A.R.)
- Department of Clinical Medicine, University of Copenhagen, 2100 Copenhagen, Denmark
| | - Michael Bachmann Nielsen
- Department of Diagnostic Radiology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark; (M.B.N.); (L.B.L.); (K.L.H.)
- Department of Surgical Gastroenterology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark; (M.T.); (P.S.U.); (M.P.A.); (T.A.R.)
| | - Lars Birger Lönn
- Department of Diagnostic Radiology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark; (M.B.N.); (L.B.L.); (K.L.H.)
- Department of Surgical Gastroenterology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark; (M.T.); (P.S.U.); (M.P.A.); (T.A.R.)
| | - Kristoffer Lindskov Hansen
- Department of Diagnostic Radiology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark; (M.B.N.); (L.B.L.); (K.L.H.)
- Department of Surgical Gastroenterology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark; (M.T.); (P.S.U.); (M.P.A.); (T.A.R.)
| |
Collapse
|
42
|
Sauter AP, Kössinger A, Beck S, Deniffel D, Dapper H, Combs SE, Rummeny EJ, Pfeiffer D. Dual-energy CT parameters in correlation to MRI-based apparent diffusion coefficient: evaluation in rectal cancer after radiochemotherapy. Acta Radiol Open 2020; 9:2058460120945316. [PMID: 32995044 PMCID: PMC7503032 DOI: 10.1177/2058460120945316] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2020] [Accepted: 07/03/2020] [Indexed: 01/04/2023] Open
Abstract
Background Rectal cancer (RC) is a frequent malignancy for which magnetic resonance imaging (MRI) is the most common and accurate imaging. Iodine concentration (IC) can be quantified with spectral dual-layer computed tomography CT (DL-CT), which could improve imaging of RC, especially for evaluation of response to radiochemotherapy (RCT). Purpose To compare a DL-CT system to MRI as the non-invasive imaging gold standard for imaging of RC to evaluate the possibility of a response evaluation with DL-CT. Material and Methods Eleven patients who received DL-CT as well as MRI before and after RCT of RC were retrospectively included into this study. For each examination, a region of interest (ROI) was placed within the tumor. For MRI, the mean apparent diffusion coefficient (ADC) was assessed. For DL-CT, IC, z-effective, and Hounsfield Units (HU) were measured. IC, z-effective, and HU were normalized to the aorta. ADC was correlated to absolute and relative normalized IC, z-effective, and HU with Spearman’s ρ. Differences before and after treatment were tested with Wilcoxon signed-rank test. Results HU, IC, and Z-effective values in DL-CT images decreased significantly after RCT (P<0.01 for each comparison). The mean ADC increased significantly after RCT. Spearman’s ρ of the absolute IC difference and the absolute ADC (both before and after RCT) is high and significant (ρ = 0.73; P = 0.01), whereas the ρ-value for z-effective (ρ = 0.56) or HU (ρ = 0.45) to ADC was lower and non-significant. Conclusion Response evaluation of RC after RCT could be possible with DL-CT via the measurement of IC.
Collapse
Affiliation(s)
- Andreas P Sauter
- Department of Diagnostic and Interventional Radiology, School of Medicine, Technical University of Munich, Klinikum rechts der Isar, Munich, Germany
| | - Antonia Kössinger
- Department of Diagnostic and Interventional Radiology, School of Medicine, Technical University of Munich, Klinikum rechts der Isar, Munich, Germany
| | - Stefanie Beck
- Department of Diagnostic and Interventional Radiology, School of Medicine, Technical University of Munich, Klinikum rechts der Isar, Munich, Germany
| | - Dominik Deniffel
- Department of Diagnostic and Interventional Radiology, School of Medicine, Technical University of Munich, Klinikum rechts der Isar, Munich, Germany
| | - Hendrik Dapper
- Department of Radiation Oncology, School of Medicine, Technical University of Munich, Klinikum rechts der Isar, Munich, Germany.,Department of Radiation Sciences (DRS), Institute of Radiation Medicine (IRM), Helmholtz Zentrum München, Neuherberg, Germany.,Deutsches Konsortium für Translationale Krebsforschung (dktk), Partner Site Munich, Munich, Germany
| | - Stephanie E Combs
- Department of Radiation Oncology, School of Medicine, Technical University of Munich, Klinikum rechts der Isar, Munich, Germany.,Department of Radiation Sciences (DRS), Institute of Radiation Medicine (IRM), Helmholtz Zentrum München, Neuherberg, Germany.,Deutsches Konsortium für Translationale Krebsforschung (dktk), Partner Site Munich, Munich, Germany
| | - Ernst J Rummeny
- Department of Diagnostic and Interventional Radiology, School of Medicine, Technical University of Munich, Klinikum rechts der Isar, Munich, Germany
| | - Daniela Pfeiffer
- Department of Diagnostic and Interventional Radiology, School of Medicine, Technical University of Munich, Klinikum rechts der Isar, Munich, Germany
| |
Collapse
|
43
|
Çamlıdağ İ, Nural MS, Kalkan C, Danacı M. Discrimination of papillary renal cell carcinoma from benign proteinaceous cyst based on iodine and water content on rapid kV-switching dual-energy CT. ACTA ACUST UNITED AC 2020; 26:390-395. [PMID: 32755880 DOI: 10.5152/dir.2020.19483] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
PURPOSE We aimed to evaluate whether rapid kV-switching dual energy CT (rsDECT) can discriminate between papillary renal cell carcinoma (RCC) and benign proteinaceous cysts (BPCs) based on iodine and water content. METHODS Twenty-four patients with histopathologically proven papillary RCC and 38 patients with 41 BPCs were retrospectively included. Patients with BPCs were eligible for inclusion when the cysts were stable in size and appearance for at least 2 years or proved to be a cyst on ultrasound or MRI. All patients underwent delayed phase (70-90 s) rsDECT. Iodine and water content of each lesion was measured on the workstation. RESULTS Of papillary RCC patients, 4 (16%) were female and 20 (84%) were male. Mean tumor size was 39±20 mm. Mean iodine and water content was 2.08±0.7 mg/mL and 1021±14 mg/mL, respectively. Of BPC patients, 9 were female and 29 were male. Mean cyst size was 20±7 mm. Mean iodine and water content was 0.82±0.4 mg/mL and 1012±14 mg/mL, respectively. There were significant differences between iodine and water contents of papillary RCCs and BPCs (P < 0.001). The best cutoff of iodine content for differentiating papillary RCC from BPC was 1.21 mg/mL (area under the curve [AUC]=0.97, P < 0.001, sensitivity 96%, specificity 88%, positive predictive value [PPV] 82%, negative predictive value [NPV] 97%, accuracy 91%,); the best cutoff of water content was 1015.5 mg/mL (AUC=0.68, P = 0.016, sensitivity 83%, specificity 56%, PPV 52%, NPV 85%, accuracy 66%). CONCLUSION An iodine content threshold of 1.21 mg/mL accurately differentiates papillary RCC from BPCs on a single postcontrast rsDECT. Despite having a high sensitivity, water content has inferior diagnostic accuracy.
Collapse
Affiliation(s)
- İlkay Çamlıdağ
- Department of Radiology, Ondokuz Mayıs University School of Medicine, Samsun, Turkey
| | - Mehmet Selim Nural
- Department of Radiology, Ondokuz Mayıs University School of Medicine, Samsun, Turkey
| | - Cihan Kalkan
- Department of Radiology, Ondokuz Mayıs University School of Medicine, Samsun, Turkey
| | - Murat Danacı
- Department of Urology, Ondokuz Mayıs University School of Medicine, Samsun, Turkey
| |
Collapse
|
44
|
Patel BN, Boltyenkov AT, Martinez MG, Mastrodicasa D, Marin D, Jeffrey RB, Chung B, Pandharipande P, Kambadakone A. Cost-effectiveness of dual-energy CT versus multiphasic single-energy CT and MRI for characterization of incidental indeterminate renal lesions. Abdom Radiol (NY) 2020; 45:1896-1906. [PMID: 31894384 DOI: 10.1007/s00261-019-02380-x] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
PURPOSE To evaluate the cost-effectiveness of DECT versus multiphasic CT and MRI for characterizing small incidentally detected indeterminate renal lesions using a Markov Monte Carlo decision-analytic model. BACKGROUND Incidental renal lesions are commonly encountered due to the increasing utilization of medical imaging and the increasing prevalence of renal lesions with age. Currently recommended imaging modalities to further characterize incidental indeterminate renal lesions have some inherent drawbacks. Single-phase DECT may overcome these limitations, but its cost-effectiveness remains uncertain. MATERIALS AND METHODS A decision-analytic (Markov) model was constructed to estimate life expectancy and lifetime costs for otherwise healthy 64-year-old patients with small (≤ 4 cm) incidentally detected, indeterminate renal lesions on routine imaging (e.g., ultrasound or single-phase CT). Three strategies for evaluating renal lesions for enhancement were compared: multiphase SECT (e.g., true unenhanced and nephrographic phase), multiphasic MRI, and single-phase DECT (nephrographic phase in dual-energy mode). The model incorporated modality-specific diagnostic test performance, incidence, and prevalence of incidental renal cell carcinomas (RCCs), effectiveness, costs, and health outcomes. An incremental cost-effectiveness analysis was performed to identify strategy preference at willingness-to-pay (WTP) thresholds of $50,000 and $100,000 per quality-adjusted life-year (QALY) gained. Deterministic and probabilistic sensitivity analysis were performed. RESULTS In the base case analysis, expected mean costs per patient undergoing characterization of incidental renal lesions were $2567 for single-phase DECT, $3290 for multiphasic CT, and $3751 for multiphasic MRI. Associated quality-adjusted life-years were the highest for single-phase DECT at 0.962, for multiphasic MRI it was 0.940, and was the lowest for multiphasic CT at 0.925. Because of lower associated costs and higher effectiveness, the single-phase DECT strategy dominated the other two strategies. CONCLUSIONS Single-phase DECT is potentially more cost-effective than multiphasic SECT and MRI for evaluating small incidentally detected indeterminate renal lesions.
Collapse
|
45
|
Sauter AP, Shapira N, Kopp FK, Aichele J, Bodden J, Knipfer A, Rummeny EJ, Noël PB. CTPA with a conventional CT at 100 kVp vs. a spectral-detector CT at 120 kVp: Comparison of radiation exposure, diagnostic performance and image quality. Eur J Radiol Open 2020; 7:100234. [PMID: 32420413 PMCID: PMC7215101 DOI: 10.1016/j.ejro.2020.100234] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2020] [Revised: 04/10/2020] [Accepted: 04/18/2020] [Indexed: 12/15/2022] Open
Abstract
With SD-CT, increased radiation exposure is not present. In the current study, CTDIvol was lower with SD-CT than with C-CT, even when 100 kVp was used for the latter. With SD-CT, higher levels of diagnostic performance and image quality can be achieved. SD-CT may be the system of choice due to the availability of spectral data and thus additional image information.
Purpose To compare CT pulmonary angiographies (CTPAs) as well as phantom scans obtained at 100 kVp with a conventional CT (C-CT) to virtual monochromatic images (VMI) obtained with a spectral detector CT (SD-CT) at equivalent dose levels as well as to compare the radiation exposure of both systems. Material and Methods In total, 2110 patients with suspected pulmonary embolism (PE) were examined with both systems. For each system (C-CT and SD-CT), imaging data of 30 patients with the same mean CT dose index (4.85 mGy) was used for the reader study. C-CT was performed with 100 kVp and SD-CT was performed with 120 kVp; for SD-CT, virtual monochromatic images (VMI) with 40, 60 and 70 keV were calculated. All datasets were evaluated by three blinded radiologists regarding image quality, diagnostic confidence and diagnostic performance (sensitivity, specificity). Contrast-to-noise ratio (CNR) for different iodine concentrations was evaluated in a phantom study. Results CNR was significantly higher with VMI at 40 keV compared to all other datasets. Subjective image quality as well as sensitivity and specificity showed the highest values with VMI at 60 keV and 70 keV. Hereby, a significant difference to 100 kVp (C-CT) was found for image quality. The highest sensitivity was found using VMI at 60 keV with a sensitivity of more than 97 % for all localizations of PE. For diagnostic confidence and subjective contrast, highest values were found with VMI at 40 keV. Conclusion Higher levels of diagnostic performance and image quality were achieved for CPTAs with SD-CT compared to C-CT given similar dose levels. In the clinical setting SD-CT may be the modality of choice as additional spectral information can be obtained.
Collapse
Key Words
- BMI, body mass index
- C-CT, conventional spiral CT
- CNR, contrast-to-noise ratio
- CT, computed tomography
- CTDIVOL, volume-weighted CT dose index
- CTPA, CT pulmonary angiography
- Computed tomography angiography
- DE-CT, dual-Energy CT
- DLP, dose length product
- DS-CT, dual-Source CT
- ED, effective dose
- HU, Hounsfield Units
- IQ, image quality
- PE, pulmonary embolism
- Patient safety
- Pulmonary embolism
- ROI, region of interest
- Radiation exposure
- Radiologic
- SD-CT, spectral-detector CT
- Technology
- VMI, virtual monochromatic images
- kVp, peak kilovoltage
- keV, kilo-electronvolt
Collapse
Affiliation(s)
- Andreas P Sauter
- Technical University of Munich, School of Medicine, Klinikum rechts der Isar, Department of Diagnostic and Interventional Radiology, Munich, Germany
| | - Nadav Shapira
- Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, USA.,Philips Healthcare, Haifa, Israel
| | - Felix K Kopp
- Technical University of Munich, School of Medicine, Klinikum rechts der Isar, Department of Diagnostic and Interventional Radiology, Munich, Germany
| | - Juliane Aichele
- Technical University of Munich, School of Medicine, Klinikum rechts der Isar, Department of Diagnostic and Interventional Radiology, Munich, Germany
| | - Jannis Bodden
- Technical University of Munich, School of Medicine, Klinikum rechts der Isar, Department of Diagnostic and Interventional Radiology, Munich, Germany
| | - Andreas Knipfer
- Technical University of Munich, School of Medicine, Klinikum rechts der Isar, Department of Diagnostic and Interventional Radiology, Munich, Germany
| | - Ernst J Rummeny
- Technical University of Munich, School of Medicine, Klinikum rechts der Isar, Department of Diagnostic and Interventional Radiology, Munich, Germany
| | - Peter B Noël
- Technical University of Munich, School of Medicine, Klinikum rechts der Isar, Department of Diagnostic and Interventional Radiology, Munich, Germany.,Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, USA
| |
Collapse
|
46
|
Byrne D, Walsh JP, Schmiedeskamp H, Settecase F, Heran MKS, Niu B, Salmeen AK, Rohr B, Field TS, Murray N, Rohr A. Prediction of Hemorrhage after Successful Recanalization in Patients with Acute Ischemic Stroke: Improved Risk Stratification Using Dual-Energy CT Parenchymal Iodine Concentration Ratio Relative to the Superior Sagittal Sinus. AJNR Am J Neuroradiol 2020; 41:64-70. [PMID: 31896566 DOI: 10.3174/ajnr.a6345] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2019] [Accepted: 10/08/2019] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE Brain parenchymal hyperdensity on postthrombectomy CT in patients with acute stroke can be due to hemorrhage and/or contrast staining. We aimed to determine whether iodine concentration within contrast-stained parenchyma compared with an internal reference in the superior sagittal sinus on dual-energy CT could predict subsequent intracerebral hemorrhage. MATERIALS AND METHODS Seventy-one patients with small infarct cores (ASPECTS ≥ 7) and good endovascular recanalization (modified TICI 2b or 3) for anterior circulation large-vessel occlusion were included. Brain parenchymal iodine concentration as per dual-energy CT and the percentage of contrast staining relative to the superior sagittal sinus were recorded and correlated with the development of intracerebral hemorrhage using Mann-Whitney U and Fisher exact tests. RESULTS Forty-three of 71 patients had parenchymal hyperdensity on initial dual-energy CT. The median relative iodine concentration compared with the superior sagittal sinus was significantly higher in those with subsequent intracerebral hemorrhage (137.9% versus 109.2%, P = .007). By means of receiver operating characteristic analysis, a cutoff value of 100% (iodine concentration relative to the superior sagittal sinus) enabled identification of patients going on to develop intracerebral hemorrhage with 94.75% sensitivity, 43.4% specificity, and a likelihood ratio of 1.71. CONCLUSIONS Within our cohort of patients, the relative percentage of iodine concentration at dual-energy CT compared with the superior sagittal sinus was a reliable predictor of intracerebral hemorrhage development and may be a useful imaging biomarker for risk stratification after endovascular treatment.
Collapse
Affiliation(s)
- D Byrne
- From the Division of Neuroradiology (D.B., F.S., M.K.S.H., A.R.) .,University of British Columbia (D.B., J.P.W., F.S., M.K.S.H., B.R., T.S.F., N.M., A.R.), Vancouver, British Columbia, Canada
| | - J P Walsh
- Department of Emergency Radiology (J.P.W., N.M.).,University of British Columbia (D.B., J.P.W., F.S., M.K.S.H., B.R., T.S.F., N.M., A.R.), Vancouver, British Columbia, Canada
| | | | - F Settecase
- From the Division of Neuroradiology (D.B., F.S., M.K.S.H., A.R.).,University of British Columbia (D.B., J.P.W., F.S., M.K.S.H., B.R., T.S.F., N.M., A.R.), Vancouver, British Columbia, Canada
| | - M K S Heran
- From the Division of Neuroradiology (D.B., F.S., M.K.S.H., A.R.).,University of British Columbia (D.B., J.P.W., F.S., M.K.S.H., B.R., T.S.F., N.M., A.R.), Vancouver, British Columbia, Canada
| | - B Niu
- Vancouver Imaging (B.N.), Vancouver General Hospital, Vancouver, British Columbia, Canada
| | - A K Salmeen
- Division of Neurology (A.K.S., T.S.F.), Department of Medicine, Vancouver Stroke Program, Brain Research Center, University of British Columbia, Vancouver, British Columbia, Canada
| | - B Rohr
- University of British Columbia (D.B., J.P.W., F.S., M.K.S.H., B.R., T.S.F., N.M., A.R.), Vancouver, British Columbia, Canada
| | - T S Field
- Division of Neurology (A.K.S., T.S.F.), Department of Medicine, Vancouver Stroke Program, Brain Research Center, University of British Columbia, Vancouver, British Columbia, Canada.,University of British Columbia (D.B., J.P.W., F.S., M.K.S.H., B.R., T.S.F., N.M., A.R.), Vancouver, British Columbia, Canada
| | - N Murray
- Department of Emergency Radiology (J.P.W., N.M.).,University of British Columbia (D.B., J.P.W., F.S., M.K.S.H., B.R., T.S.F., N.M., A.R.), Vancouver, British Columbia, Canada
| | - A Rohr
- From the Division of Neuroradiology (D.B., F.S., M.K.S.H., A.R.).,University of British Columbia (D.B., J.P.W., F.S., M.K.S.H., B.R., T.S.F., N.M., A.R.), Vancouver, British Columbia, Canada
| |
Collapse
|
47
|
Udare A, Walker D, Krishna S, Chatelain R, McInnes MD, Flood TA, Schieda N. Characterization of clear cell renal cell carcinoma and other renal tumors: evaluation of dual-energy CT using material-specific iodine and fat imaging. Eur Radiol 2019; 30:2091-2102. [PMID: 31858204 DOI: 10.1007/s00330-019-06590-1] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2019] [Revised: 11/02/2019] [Accepted: 11/12/2019] [Indexed: 12/16/2022]
Abstract
OBJECTIVE This study aimed to assess material-specific iodine and fat images for diagnosis of clear cell renal cell carcinoma (cc-RCC) compared to papillary RCC (p-RCC) and other renal masses. MATERIALS AND METHODS With IRB approval, we identified histologically confirmed solid renal masses that underwent rapid-kVp-switch DECT between 2016 and 2018: 25 cc-RCC (7 low grade versus 18 high grade), 11 p-RCC, and 6 other tumors (2 clear cell papillary RCC, 2 chromophobe RCC, 1 oncocytoma, 1 renal angiomyomatous tumor). A blinded radiologist measured iodine and fat concentration on material-specific iodine-water and fat-water basis pair images. Comparisons were performed between groups using univariate analysis and diagnostic accuracy calculated by ROC. RESULTS Iodine concentration was higher in cc-RCC (6.14 ± 1.79 mg/mL) compared to p-RCC (1.40 ± 0.54 mg/mL, p < 0.001), but not compared to other tumors (5.0 ± 2.2 mg/mL, p = 0.370). Intratumoral fat was seen in 36.0% (9/25) cc-RCC (309.6 ± 234.3 mg/mL [71.1-762.3 ng/mL]), 9.1% (1/11) papillary RCC (97.11 mg/mL), and no other tumors (p = 0.036). Iodine concentration ≥ 3.99 mg/mL achieved AUC and sensitivity/specificity of 0.88 (CI 0.76-1.00) and 92.31%/82.40% to diagnose cc-RCC. To diagnose p-RCC, iodine concentration ≤ 2.5 mg/mL achieved AUC and sensitivity/specificity of 0.99 (0.98-1.00) and 100%/100%. The presence of intratumoral fat had AUC 0.64 (CI 0.53-0.75) and sensitivity/specificity of 34.6%/93.8% to diagnose cc-RCC. A logistic regression model combining iodine concentration and presence of fat increased AUC to 0.91 (CI 0.81-1.0) with sensitivity/specificity of 80.8%/93.8% to diagnose cc-RCC. CONCLUSION Iodine concentration values are highly accurate to differentiate clear cell RCC from papillary RCC; however, they overlap with other tumors. Fat-specific images may improve differentiation of clear cell RCC from other avidly enhancing tumors. KEY POINTS • Clear cell renal cell carcinoma (RCC) has significantly higher iodine concentration than papillary RCC, but there is an overlap in values comparing clear cell RCC to other renal tumors. • Iodine concentration ≤ 2.5 mg/mL is highly accurate to differentiate papillary RCC from clear cell RCC and other renal tumors. • The presence of microscopic fat on material-specific fat images was specific for clear cell RCC, helping to differentiate clear cell RCC from other avidly enhancing renal tumors.
Collapse
Affiliation(s)
- Amar Udare
- Department of Medical Imaging, The Ottawa Hospital, University of Ottawa, 1053 Carling Avenue, Ottawa, ON, K1Y 4E9, Canada
| | - Daniel Walker
- Department of Medical Imaging, The Ottawa Hospital, University of Ottawa, 1053 Carling Avenue, Ottawa, ON, K1Y 4E9, Canada
| | - Satheesh Krishna
- Joint Department of Medical Imaging, Toronto General Hospital, The University of Toronto, Toronto, Canada
| | - Robert Chatelain
- Department of Medical Imaging, The Ottawa Hospital, University of Ottawa, 1053 Carling Avenue, Ottawa, ON, K1Y 4E9, Canada
| | - Matthew Df McInnes
- Department of Medical Imaging, The Ottawa Hospital, University of Ottawa, 1053 Carling Avenue, Ottawa, ON, K1Y 4E9, Canada
| | - Trevor A Flood
- Department of Anatomical Pathology, The Ottawa Hospital, University of Ottawa, Ottawa, ON, Canada
| | - Nicola Schieda
- Department of Medical Imaging, The Ottawa Hospital, University of Ottawa, 1053 Carling Avenue, Ottawa, ON, K1Y 4E9, Canada.
| |
Collapse
|
48
|
Zhou W, Michalak G, Weaver J, Ferrero A, Gong H, Fetterly KA, McCollough CH, Leng S. Determination of iodine detectability in different types of multiple-energy images for a photon-counting detector computed tomography system. J Med Imaging (Bellingham) 2019; 6:043501. [PMID: 31620546 DOI: 10.1117/1.jmi.6.4.043501] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2019] [Accepted: 09/16/2019] [Indexed: 11/14/2022] Open
Abstract
In addition to low-energy-threshold images (TLIs), photon-counting detector (PCD) computed tomography (CT) can generate virtual monoenergetic images (VMIs) and iodine maps. Our study sought to determine the image type that maximizes iodine detectability. Adult abdominal phantoms with iodine inserts of various concentrations and lesion sizes were scanned on a PCD-CT system. TLIs, VMIs at 50 keV, and iodine maps were generated, and iodine contrast-to-noise ratio (CNR) was measured. A channelized Hotelling observer was used to determine the area under the receiver-operating-characteristic curve (AUC) for iodine detectability. Iodine map CNR ( 0.57 ± 0.42 ) was significantly higher ( P < 0.05 ) than for TLIs ( 0.46 ± 0.26 ) and lower ( P < 0.001 ) than for VMIs at 50 keV ( 0.74 ± 0.33 ) for 0.5 mgI/cc and a 35-cm phantom. For the same condition and an 8-mm lesion, iodine detectability from iodine maps ( AUC = 0.95 ± 0.01 ) was significantly lower ( P < 0.001 ) than both TLIs ( AUC = 0.99 ± 0.00 ) and VMIs ( AUC = 0.99 ± 0.01 ). VMIs at 50 keV had similar detectability to TLIs and both outperformed iodine maps. The lowest detectable iodine concentration was 0.5 mgI/cc for an 8-mm lesion and 1.0 mgI/cc for a 4-mm lesion.
Collapse
Affiliation(s)
- Wei Zhou
- Mayo Clinic, Department of Radiology, Rochester, Minnesota, United States
| | - Gregory Michalak
- Mayo Clinic, Department of Radiology, Rochester, Minnesota, United States
| | - Jayse Weaver
- Mayo Clinic, Department of Radiology, Rochester, Minnesota, United States
| | - Andrea Ferrero
- Mayo Clinic, Department of Radiology, Rochester, Minnesota, United States
| | - Hao Gong
- Mayo Clinic, Department of Radiology, Rochester, Minnesota, United States
| | - Kenneth A Fetterly
- Mayo Clinic, Department of Radiology, Rochester, Minnesota, United States.,Mayo Clinic, Department of Cardiovascular Medicine, Rochester, Minnesota, United States
| | | | - Shuai Leng
- Mayo Clinic, Department of Radiology, Rochester, Minnesota, United States
| |
Collapse
|
49
|
Kessner R, Große Hokamp N, Ciancibello L, Ramaiya N, Herrmann KA. Renal cystic lesions characterization using spectral detector CT (SDCT): Added value of spectral results. Br J Radiol 2019; 92:20180915. [PMID: 31124701 DOI: 10.1259/bjr.20180915] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022] Open
Abstract
OBJECTIVES To evaluate the added value of spectral results derived from Spectral Detector CT (SDCT) to the characterization of renal cystic lesions (RCL). METHODS This retrospective study was approved by the local Institutional review board. 70 consecutive patients who underwent abdominopelvic SDCT and had at least one RCL were included. 84 RCL were categorized as simple, complex or neoplastic based on attenuation values on single-phase post-contrast images. Attenuation values were measured in each lesion on standard conventional CT images (stCI) and virtual monoenergetic images of 40keV and 100keV. A spectral curve slope was calculated and intra lesional iodine concentration (IC) was measured using iodine-density maps. Reference standard was established using histopathologic correlation, prior and follow-up imaging. Analysis of variance (ANOVA) was used to compare between the groups. RESULTS Mean attenuation values for benign simple and complex RCL differed significantly (42 ± 16 vs 8 ± 3 HU; p < 0.001). IC was almost identical in benign simple and complex RCL (0.23 ± 0.04 mg ml-1 vs 0.24 ± 0.04 mg ml-1), while IC in neoplastic RCL was significantly higher (2.10 ± 0.08 mg ml-1 ; p < 0.001). The mean spectral curve slope did not differ significantly between simple and complex RCL (0.30 ± 0.03 vs 0.33 ± 0.05) but was significantly higher in neoplastic RCL (2.60 ± 0.10; p < 0.001). CONCLUSIONS Spectral results of SDCT are highly promising in distinguishing benign complex RCL from enhancing neoplastic RCL based on single-phase post-contrast imaging only. ADVANCES IN KNOWLEDGE SDCT can assist in differentiating between benign complex and neoplastic renal cystic lesions.
Collapse
Affiliation(s)
- Rivka Kessner
- 1 Department of Radiology, University Hospitals Cleveland Medical Center and Case Western Reserve University, Cleveland, Ohio, USA.,2 Department of Diagnostic Imaging, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Nils Große Hokamp
- 1 Department of Radiology, University Hospitals Cleveland Medical Center and Case Western Reserve University, Cleveland, Ohio, USA.,3 University Hospital Cologne, Institute for Diagnostic and Interventional Radiology, Cologne, Germany
| | - Les Ciancibello
- 1 Department of Radiology, University Hospitals Cleveland Medical Center and Case Western Reserve University, Cleveland, Ohio, USA
| | - Nikhil Ramaiya
- 1 Department of Radiology, University Hospitals Cleveland Medical Center and Case Western Reserve University, Cleveland, Ohio, USA
| | - Karin A Herrmann
- 1 Department of Radiology, University Hospitals Cleveland Medical Center and Case Western Reserve University, Cleveland, Ohio, USA
| |
Collapse
|
50
|
Diagnostic Accuracy of Attenuation Difference and Iodine Concentration Thresholds at Rapid-Kilovoltage-Switching Dual-Energy CT for Detection of Enhancement in Renal Masses. AJR Am J Roentgenol 2019; 213:619-625. [PMID: 31120787 DOI: 10.2214/ajr.18.20990] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
OBJECTIVE. The objective of our study was to evaluate iodine concentration and attenuation change in Hounsfield unit (ΔHU) thresholds to diagnose enhancement in renal masses at rapid-kilovoltage-switching dual-energy CT (DECT). MATERIALS AND METHODS. We evaluated 30 consecutive histologically confirmed solid renal masses (including nine papillary renal cell carcinomas [RCCs]) and 27 benign cysts (17 simple and 10 hemorrhagic or proteinaceous cysts) with DECT December 2016 and May 2018. A blinded radiologist measured iodine concentration (in milligrams per milliliter) and ΔHU (attenuation on enhanced CT - attenuation on unenhanced CT) using 70-keV corticomedullary (CM) phase virtual monochromatic and 120-kVp nephrographic (NG) phase images. The accuracies of previously described enhancement thresholds were compared by ROC curve analysis. RESULTS. An iodine concentration of ≥ 2.0 mg/mL and an iodine concentration of ≥ 1.2 mg/mL achieved sensitivity, specificity, and the area under the ROC curve (AUC) of 73.3%, 100.0%, and 0.87 and 86.7%, 100.0%, and 0.93, respectively. On 70-keV CM phase images, ΔHU ≥ 20 HU and ΔHU ≥ 15 HU yielded sensitivity, specificity, and AUC of 80.0%, 100.0%, and 0.90 and 90.0%, 100.0%, and 0.95, respectively. The numbers of incorrectly classified papillary RCCs were as follows: iodine concentration of ≥ 2.0 mg/mL, 77.8% (7/9; range, 0.7-1.6 mg/mL); iodine concentration of ≥ 1.2 mg/mL, 44.4% (4/9; range, 0.7-0.9 mg/mL); ΔHU ≥ 20 HU on 70-keV CM phase images, 66.7% (6/9; range, 4-17 HU); and ΔHU ≥ 15 HU on 70-keV DECT images, 33.3% (3/9; 4-12 HU). No cyst pseudoenhancement occurred on DECT. For 120-kVp NG phase DECT, ΔHU ≥ 20 HU and ΔHU ≥ 15 HU yielded sensitivity, specificity, and AUC of 93.3%, 96.3%, and 0.95 and 100.0%, 88.9%, and 0.94, respectively. With ΔHU ≥ 20 HU, 22.2% (2/9) (range, 15-18 HU) of papillary RCCs were misclassified and there was one pseudoenhancing cyst. With ΔHU ≥ 15 HU, no papillary RCCs were misclassified but 11.1% (3/27) of cysts showed pseudoenhancement. Only an iodine concentration of ≥ 2.0 mg/mL showed significantly lower accuracy than other measures (p = 0.031-0.045). CONCLUSION. DECT applied in the CM phase performed best using an iodine concentration of ≥ 1.2 mg/mL or a 70-keV ΔHU ≥ 15 HU; these parameters improved sensitivity for the detection of enhancement in renal masses without instances of cyst pseudoenhancement.
Collapse
|