Stinis CT, Abbas AE, Teirstein P, Makkar RR, Chung CJ, Iyer V, Généreux P, Kipperman RM, Harrison JK, Hughes GC, Lyons JM, Rahman A, Kakouros N, Walker J, Roberts DK, Huang PH, Kar B, Dhoble A, Logsdon DP, Khanna PK, Aragon J, McCabe JM. Real-World Outcomes for the Fifth-Generation Balloon Expandable Transcatheter Heart Valve in the United States. JACC Cardiovasc Interv 2024; 17:1032-1044. [PMID: 38456883 DOI: 10.1016/j.jcin.2024.02.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/17/2024] [Revised: 02/14/2024] [Accepted: 02/14/2024] [Indexed: 03/09/2024]
Abstract
BACKGROUND The fifth-generation SAPIEN 3 Ultra Resilia valve (S3UR) incorporates several design changes as compared with its predecessors, the SAPIEN 3 (S3) and SAPIEN 3 Ultra (S3U) valves, including bovine leaflets treated with a novel process intended to reduce structural valve deterioration via calcification, as well as a taller external skirt on the 29-mm valve size to reduce paravalvular leak (PVL). The clinical performance of S3UR compared with S3 and S3U in a large patient population has not been previously reported. OBJECTIVES The aim of this study was to compare S3UR to S3/S3U for procedural, in-hospital, and 30-day clinical and echocardiographic outcomes after transcatheter aortic valve replacement (TAVR). METHODS Patients enrolled in the STS/ACC TVT (Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy) Registry between January 1, 2021, and June 30, 2023, who underwent TAVR with S3UR or S3U/S3 valve platforms were propensity-matched and evaluated for procedural, in-hospital, and 30-day clinical and echocardiographic outcomes. RESULTS 10,314 S3UR patients were propensity matched with 10,314 patients among 150,539 S3U/S3 patients. At 30 days, there were no statistically significant differences in death, stroke, or bleeding, but a numerically higher hospital readmission rate in the S3UR cohort (8.5% vs 7.7%; P = 0.04). At discharge, S3UR patients exhibited significantly lower mean gradients (9.2 ± 4.6 mm Hg vs 12.0 ± 5.7 mm Hg; P < 0.0001) and larger aortic valve area (2.1 ± 0.7 cm2 vs 1.9 ± 0.6 cm2; P < 0.0001) than patients treated with S3/S3U. The 29-mm valve size exhibited significant reduction in mild PVL (5.3% vs 9.4%; P < 0.0001). CONCLUSIONS S3UR TAVR is associated with lower mean gradients and lower rates of PVL than earlier generations of balloon expandable transcatheter heart valve platforms.
Collapse
Affiliation(s)
- Curtiss T Stinis
- Division of Cardiology, Scripps Clinic, La Jolla, California, USA.
| | - Amr E Abbas
- Corewell Health East, William Beaumont University Hospital, Royal Oak, Michigan, USA
| | - Paul Teirstein
- Division of Cardiology, Scripps Clinic, La Jolla, California, USA
| | - Raj R Makkar
- Cedars-Sinai Medical Center, Los Angeles, California, USA
| | - Christine J Chung
- University of Washington Medical Center, Department of Medicine, Division of Cardiology, Seattle, Washington, USA
| | - Vijay Iyer
- Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, Buffalo, New York, New York, USA
| | - Philippe Généreux
- Gagnon Cardiovascular Institute at Morristown Medical Center, Morristown, New Jersey, USA
| | - Robert M Kipperman
- Atlantic Health System Morristown Medical Center, Morristown, New Jersey, USA
| | - John K Harrison
- Division of Cardiology, Department of Medicine, Duke University Hospital, Durham, North Carolina, USA
| | - G Chad Hughes
- Division of Cardiology, Department of Medicine, Duke University Hospital, Durham, North Carolina, USA
| | | | - Ayaz Rahman
- Cardiology Associates of East Tennessee, Knoxville, Tennessee, USA
| | - Nikolaos Kakouros
- Division of Cardiology, University of Massachusetts School of Medicine, Worcester, MA, USA
| | - Jennifer Walker
- Department of Medicine, Division of Cardiology, University of North Carolina at Chapel Hill, North Carolina, USA
| | | | | | - Biswajit Kar
- Division of Cardiology, Department of Internal Medicine, University of Texas Health Science Center, Houston, Texas, USA
| | - Abhijeet Dhoble
- Division of Cardiology, Department of Internal Medicine, University of Texas Health Science Center, Houston, Texas, USA
| | | | | | - Joseph Aragon
- Santa Barbara Cottage Hospital, Santa Barbara, California, USA
| | - James M McCabe
- Division of Cardiology, University of Washington Medical Center, Seattle, Washington, USA
| |
Collapse
|
2
|
Akodad M, Meier D, Sellers S, de Backer O, Mylotte D, Landes U, Frawley C, Lynch L, Tang GHL, Sondergaard L, Wood DA, Webb JG, Sathananthan J. A bench study of balloon-expandable valves for the treatment of self-expanding valve failure. EUROINTERVENTION 2023; 19:93-102. [PMID: 36621917 PMCID: PMC10174185 DOI: 10.4244/eij-d-22-00769] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/31/2022] [Accepted: 11/08/2022] [Indexed: 01/10/2023]
Abstract
BACKGROUND Coronary obstruction and access are concerns in patients undergoing redo transcatheter aortic valve implantation (TAVI). AIMS We sought to assess the neoskirt height, leaflet overhang, leaflet deflection,and transcatheter heart valve (THV) expansion and performance, at 2 different implant depths, of the SAPIEN 3 Ultra (S3U) within the ACURATE neo2 (ACn2) THV. METHODS An in vitro study was performed with a 23 mm S3U deployed within a small (S) ACn2 and a 26 mm S3U deployed within a medium (M) and a large (L) ACn2. The S3U outflow was positioned at the top of the ACn2 crown (low implant) and at the base of the commissural post of the ACn2 (high implant). Testing was performed under physiological conditions as per ISO-5840-3 standard. RESULTS The neoskirt height was shorter when the S3U outflow was positioned at a low implantation depth (S: 9.6 mm, M: 12.2 mm, L: 13.8 mm vs S: 15.2 mm, M: 15.1 mm, L: 17.8 mm ACn2 for high implants). Hydrodynamic performance was acceptable for all configurations. Leaflet overhang was <50% for all configurations except the low implant of the 26 mm S3U in the L ACn2 (77.6%). There was a gap from the side of the neoskirt to the outer border of the THV frame which was >2 mm for all configurations. The S3U was underexpanded for all configurations, and the achieved area was 77.9%-92.9% of the expected nominal area. CONCLUSIONS Redo TAVI with an S3U within an ACn2 has favourable hydrodynamics and moderate leaflet overhang. Importantly, the design of the ACn2 results in a neoskirt that is not deflected all the way to the outer dimensions of the THV, hence creating a space that facilitates coronary flow and access.
Collapse
Affiliation(s)
- Mariama Akodad
- Centre for Heart Valve Innovation, St Paul's Hospital, University of British Columbia, Vancouver, BC, Canada
- Centre for Cardiovascular Innovation, University of British Columbia, Vancouver, BC, Canada
- Cardiovascular Translational Laboratory, Centre for Heart Lung Innovation & Providence Research, Vancouver, BC, Canada
- Institut Cardiovasculaire Paris Sud, Hôpital privé Jacques-Cartier, Ramsay Santé, Massy, France
| | - David Meier
- Centre for Heart Valve Innovation, St Paul's Hospital, University of British Columbia, Vancouver, BC, Canada
- Centre for Cardiovascular Innovation, University of British Columbia, Vancouver, BC, Canada
- Cardiovascular Translational Laboratory, Centre for Heart Lung Innovation & Providence Research, Vancouver, BC, Canada
| | - Stephanie Sellers
- Centre for Heart Valve Innovation, St Paul's Hospital, University of British Columbia, Vancouver, BC, Canada
- Centre for Cardiovascular Innovation, University of British Columbia, Vancouver, BC, Canada
- Cardiovascular Translational Laboratory, Centre for Heart Lung Innovation & Providence Research, Vancouver, BC, Canada
| | - Ole de Backer
- Department of Cardiology, The Heart Centre, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark
| | - Darren Mylotte
- Department of Cardiology, National University of Ireland, Galway, (NUIG), Galway, Ireland
| | - Uri Landes
- Edith Wolfson Medical Center, Holon, Israel and Tel-Aviv University, Tel-Aviv, Israel
| | | | - Lisa Lynch
- Boston Scientific Corporation, Marlborough, MA, USA
| | - Gilbert H L Tang
- Department of Cardiovascular Surgery, Mount Sinai Hospital, New York, NY, USA
| | - Lars Sondergaard
- Department of Cardiology, The Heart Centre, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark
| | - David A Wood
- Centre for Heart Valve Innovation, St Paul's Hospital, University of British Columbia, Vancouver, BC, Canada
- Centre for Cardiovascular Innovation, University of British Columbia, Vancouver, BC, Canada
- Cardiovascular Translational Laboratory, Centre for Heart Lung Innovation & Providence Research, Vancouver, BC, Canada
| | - John G Webb
- Centre for Heart Valve Innovation, St Paul's Hospital, University of British Columbia, Vancouver, BC, Canada
- Centre for Cardiovascular Innovation, University of British Columbia, Vancouver, BC, Canada
- Cardiovascular Translational Laboratory, Centre for Heart Lung Innovation & Providence Research, Vancouver, BC, Canada
| | - Janarthanan Sathananthan
- Centre for Heart Valve Innovation, St Paul's Hospital, University of British Columbia, Vancouver, BC, Canada
- Centre for Cardiovascular Innovation, University of British Columbia, Vancouver, BC, Canada
- Cardiovascular Translational Laboratory, Centre for Heart Lung Innovation & Providence Research, Vancouver, BC, Canada
| |
Collapse
|
3
|
Tugaoen Z, Nguyen P, Arora S, Vavalle J. The selection of transcatheter heart valves in transcatheter aortic valve replacement. Trends Cardiovasc Med 2021; 32:513-522. [PMID: 34634481 DOI: 10.1016/j.tcm.2021.10.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/10/2021] [Revised: 10/04/2021] [Accepted: 10/05/2021] [Indexed: 10/20/2022]
Abstract
Transcatheter heart valve technology has rapidly progressed since initial approval in the United States. There are currently two widely available transcatheter heart valve delivery systems approved in the US; however limited data exist on optimal device selection for various patient populations. This review explores the characteristics of currently approved transcatheter heart valve systems and scenarios where one valve system may be favored over others. We provide a simplified decision tree for selecting the optimal transcatheter valve system for specific patient-centered characteristics.
Collapse
Affiliation(s)
- Zachary Tugaoen
- Department of Medicine, University of North Carolina, Chapel Hill, NC, United States
| | - Peter Nguyen
- Division of Cardiology, University of North Carolina, Chapel Hill, NC, United States
| | - Sameer Arora
- Division of Cardiology, University of North Carolina, Chapel Hill, NC, United States
| | - John Vavalle
- Division of Cardiology, University of North Carolina, Chapel Hill, NC, United States.
| |
Collapse
|