Nagashima Y, Ishikawa T, Katsuragi J, Sasaki Y, Suzuki M, Umimura T, Sawada R, Hashiba D, Yamamoto M, Ohtori S. Radiation Exposure During Lumbar Interbody Fusion Surgery Can Be Reduced by Using a Three-Dimensional Patient-Specific Template Guide.
Cureus 2024;
16:e58787. [PMID:
38784365 PMCID:
PMC11112391 DOI:
10.7759/cureus.58787]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/22/2024] [Indexed: 05/25/2024] Open
Abstract
BACKGROUND
The use of posterior lumber interbody fusion (PLIF) using cortical bone trajectory (CBT) with a patient-specific 3D template guide is increasingly widespread. To our knowledge, no studies have extensively evaluated the reduction of radiation exposure when using patient-specific drill template guides. The purpose of this study is to compare the intra-operative radiation dose and surgeon's exposure to radiation in CBT-PLIF when using a patient-specific drill guide with that in traditional minimally invasive (MIS)-PLIF.
METHODS
In this observational study, we retrospectively compared data from five patients who were treated with single-level CBT-PLIF using a patient-specific drill guide (G group) and five patients who were treated with single-level traditional MIS-PLIF (M group). We compared the surgical time, surgeon's exposure to radiation, and intra-operative radiation time and dose between the two groups of patients.
RESULTS
The mean age of the patients was 67.0 years in the M group and 74.2 years in the G group. The average surgical time was 242.8 min in the M group and 189.6 min in the G group (p = 0.020). The surgeon's exposure to radiation was 373.7 µSv in the M group and 81.75 µSv in the G group at chest level outside the protector (p = 0.00092); 42.0 µSv (M group) and 3.6 µSv (G group) at chest level inside the protector (p = 0.0000062); and 4.33 µSv (M group) and 1.20 µSv (G group) at the buttocks of the surgeon (p = 0.0013). Radiation time was 269.8 s (M group) and 56.6 s (G group) (p = 0.0097), and radiation dose was 153.7 mGy (M group) and 30.42 mGy (G group) (p = 0.00057).
CONCLUSION
The patient-specific drill template guide is an invaluable tool that facilitates the safe insertion of CBT screws with a low radiation dose from the outset.
Collapse