La Rosa GRM, Canova FS, Leotta ML, Pedullà E. Effects of heating on bioceramic sealers: a scoping review of chemo-physical properties and clinical implications. Odontology 2025; 113:1-14. [PMID: 38977543 PMCID: PMC11717877 DOI: 10.1007/s10266-024-00969-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2024] [Accepted: 06/20/2024] [Indexed: 07/10/2024]
Abstract
This scoping review aims to summarize current research to assess the impact of heating on the chemo-physical properties of bioceramic sealers. Following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) Extension for Scoping Reviews guidelines, a comprehensive literature search was conducted in April 2024 across PubMed and Scopus databases. Inclusion criteria referred to all study types evaluating the effect of heating temperature on bioceramic sealers' properties, with no language or time restrictions applied. Studies were independently screened by two reviewers, and relevant data were extracted and synthesized qualitatively. Out of 91 initially identified studies, 19 met the eligibility criteria for inclusion in the qualitative synthesis. The selected studies ranged from 2014 to 2024 and comprised laboratory-based investigations. Various bioceramic sealers, including EndoSequence BC Sealer, BioRoot RCS, and TotalFill BC, were analyzed across different heating techniques. The findings revealed divergent responses of bioceramic sealers to heat, with some demonstrating stability while others exhibited alterations in properties such as flow, setting time, and chemical composition. The impact of heat on bioceramic sealers depends on the sealer's composition and laboratory setting. While some sealers are affected significantly, others remain stable. Clinicians should carefully consider these factors when bioceramic sealers are used with warm obturation techniques, but caution is needed as real-world conditions may vary. Integrating laboratory results with clinical evidence is essential for improving treatment efficacy and patient care.
Collapse
Affiliation(s)
- Giusy Rita Maria La Rosa
- Department of General Surgery and Medical-Surgical Specialties, University of Catania, Catania, Italy.
| | - Francesco Saverio Canova
- Department of General Surgery and Medical-Surgical Specialties, University of Catania, Catania, Italy
| | - Maria Laura Leotta
- Department of General Surgery and Medical-Surgical Specialties, University of Catania, Catania, Italy
| | - Eugenio Pedullà
- Department of General Surgery and Medical-Surgical Specialties, University of Catania, Catania, Italy
| |
Collapse
|
2
|
da Costa RP, Alves Dos Santos GN, Petean IBF, Silva-Sousa AC, Camargo RV, Lopes-Olhê FC, Silva-Sousa YTC, Mazzi-Chaves JF, Sousa-Neto MD. Impact of low-fusion gutta-percha cones used in variations of the continuous wave condensation technique with filling sealers based on bioceramic compounds on the quality of root canal filling. Odontology 2024; 112:1167-1177. [PMID: 38514512 DOI: 10.1007/s10266-024-00924-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2023] [Accepted: 02/21/2024] [Indexed: 03/23/2024]
Abstract
To evaluate the impact on the quality of filling with of low-fusion and conventional gutta-percha cones. Thirty-six maxillary canines were prepared and divided into three groups: I-conventional cone with Downpack at 200 °C at 4 mm from the WL; II-low-fusion cone with Downpack at 100 °C up to 4 mm from the WL; III-low-fusion cone with Downpack at 100 °C up to 7 mm from the WL. Temperature variations were measured in thirds on the external surface of the root. The bond strength was evaluated using the push-out test. The adhesive interface was analyzed by scanning electron microscopy. The bond strength and the temperature variation data were analyzed using analysis of variance and the failure type using the chi-square test. The low-fusion cone group with 7 mm Downpack showed higher bond strength (4.2 ± 2.7) compared with conventional cones (2.8 ± 1.6) and low-fusion cones with 4 mm Downpack (2.9 ± 1.6) (p < 0.05), with occurrence of a higher number of adhesive failures to the filling material and mixed failures. Relative to temperature variation, there was less temperature change in the apical third, in the low-fusion cone with Downpack 7 mm (1.0 ± 1.0) (p < 0.05). The use of low-fusion cones allowed the continuous wave condensation technique to be performed at a lower depth of Downpack at 100 °C at 7 mm, with less heating in the apical third, without compromising the quality of filling. Using gutta-percha cones with low fusion, which permits a lower condensation temperature and reduced Downpack depth, maintains the quality of filling, in order to minimize possible damage to the periapical tissues.
Collapse
Affiliation(s)
- Rui Pereira da Costa
- Department of Restorative Dentistry, School of Dentistry of Ribeirão Preto, University of São Paulo (USP), Av. do Café, s/n., Ribeirão Preto, SP, 14020-904, Brazil
| | - Guilherme Nilson Alves Dos Santos
- Department of Restorative Dentistry, School of Dentistry of Ribeirão Preto, University of São Paulo (USP), Av. do Café, s/n., Ribeirão Preto, SP, 14020-904, Brazil
| | - Igor Bassi Ferreira Petean
- Department of Restorative Dentistry, School of Dentistry of Ribeirão Preto, University of São Paulo (USP), Av. do Café, s/n., Ribeirão Preto, SP, 14020-904, Brazil
| | - Alice Corrêa Silva-Sousa
- Department of Restorative Dentistry, School of Dentistry of Ribeirão Preto, University of São Paulo (USP), Av. do Café, s/n., Ribeirão Preto, SP, 14020-904, Brazil
| | - Rafael Verardino Camargo
- Department of Restorative Dentistry, School of Dentistry of Ribeirão Preto, University of São Paulo (USP), Av. do Café, s/n., Ribeirão Preto, SP, 14020-904, Brazil
| | - Fabiane Carneiro Lopes-Olhê
- Department of Restorative Dentistry, School of Dentistry of Ribeirão Preto, University of São Paulo (USP), Av. do Café, s/n., Ribeirão Preto, SP, 14020-904, Brazil
| | | | - Jardel Francisco Mazzi-Chaves
- Department of Restorative Dentistry, School of Dentistry of Ribeirão Preto, University of São Paulo (USP), Av. do Café, s/n., Ribeirão Preto, SP, 14020-904, Brazil
| | - Manoel Damião Sousa-Neto
- Department of Restorative Dentistry, School of Dentistry of Ribeirão Preto, University of São Paulo (USP), Av. do Café, s/n., Ribeirão Preto, SP, 14020-904, Brazil.
| |
Collapse
|
3
|
Karam M, Faraj M, Mhanna R, Khalil I, Habib M, Makhlouf M, Zogheib C. Effect of heat application on the physicochemical properties of new endodontic sealers: an in vitro and SEM study. Odontology 2024; 112:512-525. [PMID: 38070028 DOI: 10.1007/s10266-023-00871-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Accepted: 10/24/2023] [Indexed: 03/12/2024]
Abstract
Understanding the properties of endodontic sealers is vital for treatment planning. Calcium silicate-based sealers are important in modern endodontics. This study investigates the effect of heat on the physicochemical properties of new calcium silicate sealers, addressing concerns raised by clinicians seeking to combine their benefits with the gutta-percha obturation technique. Five endodontic sealers (AH Plus Bioceramic®, Total Fill® BC®, One-fil® Bioceramic, K-Biocer, Any-seal®) were evaluated. Each sealer (n = 16/group) was either kept at 37 °C or subjected to heat at 60 or 200 °C for 30 s. ISO 6876-2012 standards were used to measure setting time, flow, film thickness, and dimensional changes over time. SEM and EDS were utilized for surface and chemical analysis. Data analysis employed IBM SPSS Statistics version 26 with a 5% significance level for two-sided tests. The sealers' setting times were shortened by heat, except for Total Fill® BC with extended setting time. All sealers had significantly longer setting times than manufacturer specifications. Film thickness increased with temperature, while flow values decreased. K-Biocer sealer showed the highest flow (16.89 ± 0.57 mm) at 200 °C, while Total Fill® sealer had the lowest (15.32 ± 0.62 mm). Shrinkage was significant at 60 °C and 200 °C, with greater shrinkage at 200 °C. Heat caused surface deformations in all sealers. The 200 °C groups exhibited more voids in AH Plus Bioceramic®, Any-seal®, and One-fil® sealers, and higher void area in Total Fill®, One-fil®, and K-Biocer sealers (p value < 0.001). EDX analysis confirmed heat-induced chemical and elemental changes in all tested sealers. Elevated temperature affects the physicochemical properties and structure of the tested endodontic sealers. The consideration of endodontic sealer compatibility is essential when warm gutta-percha obturation techniques are used.
Collapse
Affiliation(s)
- Mariana Karam
- Department of Endodontics, Faculty of Dental Medicine, Saint Joseph University of Beirut, Beirut, Lebanon.
| | - Marwa Faraj
- Biomedical Engineering Program, Maroun Semaan Faculty of Engineering and Architecture, Biochemistry and Molecular Genetics Program, Faculty of Medicine, American University of Beirut, Beirut, Lebanon
| | - Rami Mhanna
- Biomedical Engineering Program, Maroun Semaan Faculty of Engineering and Architecture, American University of Beirut, Beirut, Lebanon
| | - Issam Khalil
- Department of Endodontics, Faculty of Dental Medicine, Saint Joseph University of Beirut, Beirut, Lebanon
| | - Marc Habib
- Department of Endodontics, Faculty of Dental Medicine, Saint Joseph University of Beirut, Beirut, Lebanon
| | - Michèle Makhlouf
- Department of Endodontics, Faculty of Dental Medicine, Saint Joseph University of Beirut, Beirut, Lebanon
| | - Carla Zogheib
- Department of Endodontics, Faculty of Dental Medicine, Saint Joseph University of Beirut, Beirut, Lebanon
| |
Collapse
|
4
|
Shen I, Daniel J, Vo K, Ahn C, Primus C, Komabayashi T. Use of micro-CT to examine effects of heat on coronal obturation. J Oral Sci 2022; 64:224-227. [PMID: 35661644 DOI: 10.2334/josnusd.22-0013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022]
Abstract
PURPOSE The aim of this study was to categorize the effects of heat on coronal obturation with gutta-percha and sealer using X-ray micro-computed tomography (micro-CT). METHODS Ten single-rooted, extracted human teeth were shaped using ProTaper NEXT files to size X5 (#50/Taper 6%) with 2.5% NaOCl irrigation. A single ProTaper NEXT X5 gutta-percha point was then inserted with epoxy resin (AH Plus) or tricalcium silicate (EndoSequence BC) sealer (n = 5/group), and cut at the cemento-enamel junction. The teeth were scanned using micro-CT (SkyScan1272) to obtain 11 sagittal 2-D images. Three calibrated raters categorized the coronal 0.5 mm of the images into four categories: "swirled sealer and/or gutta-percha without voids" (I), "uniform voids and sealer/gutta-percha" (II), "non-uniform voids and sealer/gutta-percha" (III), and "swirled sealer and/or gutta-percha with voids" (IV). Intra-rater and inter-rater reliability were then calculated. Chi-square tests were conducted to determine the significance of differences in each category between sealers. RESULTS The intra-class correlation coefficient was 0.55 (same rater/two different times) and Fleiss' kappa (different raters/same image) was 0.34. Categories I, II, III, and IV accounted for 16.4%, 4.2%, 30.3%, and 49.1% for AH Plus, and 6.7%, 4.2%, 27.3%, and 61.8% for EndoSequence BC, respectively. CONCLUSION Category IV was most common and Category II the least common. Significant differences were evident between sealers for Category I (P < 0.01).
Collapse
Affiliation(s)
- Ivy Shen
- University of New England College of Dental Medicine
| | - Joan Daniel
- University of New England College of Dental Medicine
| | - Kali Vo
- University of New England College of Dental Medicine
| | - Chul Ahn
- Department of Population and Data Sciences, University of Texas Southwestern Medical Center
| | | | | |
Collapse
|