1
|
Batu Eken Z, Ilie N. A Critical Review on the Factors Affecting the Bond Strength of Direct Restorative Material Alternatives to Amalgam. MATERIALS (BASEL, SWITZERLAND) 2024; 17:4853. [PMID: 39410424 PMCID: PMC11478171 DOI: 10.3390/ma17194853] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/07/2024] [Revised: 09/27/2024] [Accepted: 09/28/2024] [Indexed: 10/20/2024]
Abstract
This article comprehensively reviews the performance of simplified direct restorative materials that have the potential to be an alternative to amalgam. Following an understanding of the material structures and clinical performances, this review provides an analysis of the bonding mechanisms and influential factors on the bond strength. These factors include substrate-related variations, involving primary vs. permanent dentin, sound- vs. caries-affected/demineralized dentin comparisons and surface-related factors and pretreatments. Special attention is given to the factors changing the substrate surface, such as different contaminants, remedy methods after contamination and different conditioning methods related to the materials. Variations in sample preparation and bond strength test parameters are also evaluated for the analysis of the outcomes. This review aims to provide an overview of the factors involved in the application procedure of direct restorations together with in vitro testing variations to guide the selection of suitable materials by understanding strengths and shortcomings.
Collapse
Affiliation(s)
- Zeynep Batu Eken
- Department of Conservative Dentistry and Periodontology, LMU University Hospital, LMU Munich, Goethestr. 70, 80336 Munich, Germany;
| | | |
Collapse
|
2
|
Aljdaimi A, Devlin H, Dickinson M. Effect of the Er: YAG laser on the shear bond strength of conventional glass ionomer and Biodentine™ to dentine. Eur J Dent 2018; 12:380-385. [PMID: 30147403 PMCID: PMC6089046 DOI: 10.4103/ejd.ejd_410_17] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022] Open
Abstract
OBJECTIVES The purpose of this study was to determine if Er: YAG laser etching improves the shear bond strength (SBS) of Biodentin™ and GC Fuji IX® to dentine. MATERIALS AND METHODS Forty human dentine specimens were standardized and embedded in stone. The specimens were randomized into four groups (n = 10). Twenty samples were treated with the Er: YAG laser radiation and 10 of these restored with GC Fuji IX® and 10 with Biodentine™. The remaining 20 specimens acted as controls (no laser treatment); 10 were restored with GC Fuji IX® and 10 with Biodentin™. All samples were then stored in an incubator at 37.5°C and 100% humidity for 7 days. The SBS was determined using a Zwick universal testing machine. A two-way analysis of variance test was used to evaluate the statistical difference in SBS between the groups. An independent sample t-test was used to determine the statistical significance of differences between control and lased groups within the same material. RESULTS A highly statistically significant difference in SBS was found with the laser treatment (P = 0.0001) and material (i.e., Biodentin™ or Fuji IX® (P = 0.0001). The GC Fuji IX® group recorded the highest mean SBS required to dislodge the material from the laser-treated dentine surface (1.77 ± 0.22 Mega-Pascal [MPa]). The mean SBS of Biodentin™ to dentine following the laser radiation (1.12 ± 0.16 MPa) was significantly greater compared to the nonlased dentine (0.53 ± 0.09). Pearson Chi-square test indicated a nonsignificant relation between shear strength and mode of failure (P = 0.467). CONCLUSION Laser etching of the dentine surfaces yielded a significant increase in the bond strength for both GC Fuji IX® and Biodentin™. The SBS of Biodentin™ to dentine is greater than with conventional glass ionomer (Fuji IX®).
Collapse
Affiliation(s)
- Abtesam Aljdaimi
- Department of Restorative Dentistry, School of Dentistry, University of Manchester, Manchester, UK
- Department of Restorative Dentistry, College of Dentistry, Asmarya University, Zliten, Libya
| | - Hugh Devlin
- Department of Restorative Dentistry, School of Dentistry, University of Manchester, Manchester, UK
| | - Mark Dickinson
- Department of Photon Physics, Photon Science Institute, School of Physics and Astronomy, University of Manchester, UK
| |
Collapse
|
3
|
Soares DG, Marcomini N, Basso FG, Pansani TN, Hebling J, de Souza Costa CA. Influence of Restoration Type on the Cytotoxicity of a 35% Hydrogen Peroxide Bleaching Gel. Oper Dent 2015; 41:293-304. [PMID: 26652021 DOI: 10.2341/14-325-l] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
OBJECTIVES The tooth/restoration interface may act as a pathway for hydrogen peroxide (H2O2) diffusion into the pulp chamber. Therefore, the influence of resin-modified glass ionomer cement (RMGIC) and resin composite simulated restorations on the cytotoxicity of an in-office bleaching gel was assessed in vitro. MATERIALS AND METHODS Cavities in enamel/dentin discs restored with RMGIC Vitremer (3M ESPE) or Single Bond/Filtek Z350 (3M ESPE) resin composite (RC) were subjected or not subjected to hydrolytic degradation (HD). A 35%-H2O2 bleaching gel was applied to simulated restored and nonrestored enamel surfaces, and culture medium in contact with the dentin substrate (extract) was collected and applied to MDPC-23 cells. Nonrestored discs subjected or not subjected to bleaching were used as positive and negative controls, respectively. Cell viability, oxidative stress, interleukin (IL)-1β expression, alkaline phosphatase (ALP) activity, and mineralized nodule deposition were evaluated. The H2O2 in the extracts was quantified. Data were subjected to statistical analysis. RESULTS Higher oxidative stress associated with reduced cell viability, ALP activity, and mineralized nodule deposition was observed for all bleached groups compared with the negative control group. The RMGIC/HD group, which presented the highest H2O2 diffusion, had the lowest values of cell viability, ALP activity, and mineralized nodule deposition, as well as significantly increased IL-1β expression. CONCLUSIONS Dental cavities restored with the RMGIC subjected to hydrolytic degradation allowed for more intense diffusion of H2O2 into the pulp chamber, intensifying the toxicity of a 35%-H2O2 bleaching gel to pulp cells.
Collapse
|
4
|
Altunsoy M, Botsali MS, Korkut E, Kucukyilmaz E, Sener Y. Effect of different surface treatments on the shear and microtensile bond strength of resin-modified glass ionomer cement to dentin. Acta Odontol Scand 2014; 72:874-9. [PMID: 24844786 DOI: 10.3109/00016357.2014.919664] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
OBJECTIVE The aim of this study was to evaluate the effect of different surface treatments on the microtensile bond strength (μTBS) and shear bond strength (SBS) of resin-modified glass ionomer cement (RMGIC) to dentin. MATERIALS AND METHODS Fifty-two extracted human molars were flattened to obtain dentin surfaces. For SBS assessment 40 teeth were divided into four groups according to their surface treatments (acid etching, Er:YAG laser QSP mode, Er:YAG laser MSP mode and control-SiC) (n = 10). A plastic cylinder was placed over the differently treated dentin surfaces and RMGIC was placed into the rings and polymerized. Twelve teeth were used for the μTBS test. The treated dentin surfaces described above were restored with 4 mm high RMGIC and light cured; then, the specimens were sectioned into serial sticks (n = 15) and μTBS and SBS were tested for failure in a testing machine with a 1 mm/min crosshead speed. The data were analyzed by one-way ANOVA and Tukey HSD tests (α = 0.05). RESULTS Acid etching showed significantly higher SBS than the other groups (p < 0.05). Er:YAG QSP and MSP-treated groups showed higher SBS values than the control group, but the difference was not statistically significant (p > 0.05). Er:YAG MSP showed the highest μTBS value followed by acid etching, whereas the control group exhibited the lowest value (p < 0.05) and the differences between the control group and Er:YAG QSP were not significant (p > 0.05). CONCLUSIONS The application of Er:YAG MSP mode and acid etching to dentin can be used for improving the bond strength of RMGIC.
Collapse
Affiliation(s)
- Mustafa Altunsoy
- Department of Pediatric Dentistry, Faculty of Dentistry, Sifa University , Izmir , Turkey
| | | | | | | | | |
Collapse
|
5
|
Shahabi S, Bagheri HG, Ramazani K. Tensile bond strength of sealants following Er:YAG laser etching compared to acid etching in permanent teeth. Lasers Med Sci 2011; 27:371-5. [PMID: 21336680 DOI: 10.1007/s10103-010-0869-7] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2010] [Accepted: 11/30/2010] [Indexed: 10/18/2022]
Abstract
The aim of this in vitro study was to assess the effect of Er:YAG laser surface treatment on the tensile bond strength of a sealant in permanent teeth. A total of 30 sound third molars were selected and embedded in cold-cure acrylic resin. The enamel surfaces were flattened by a grinding. The teeth were randomly divided into three groups and pretreated as follows: (1) 37% phosphoric acid; (2) Er:YAG laser (1.5 ml/min water spray, 100 mJ energy output, 10 Hz frequency, focal distance 17 mm); (3) Er:YAG laser + 37% phosphoric acid. The treated surfaces were isolated by double adhesive Sellotape and after insertion of a split Teflon matrix at an isolated site, sealant was applied. The specimens were thermocycled and stored at 37°C in distilled water for 72 h, then subjected to a tensile bond strength test (50 kgf at 0.5 mm/min). The mean tensile bond strengths (± SD, in megapascals) were: 18.51 ± 5.68 in group 1, 8.06 ± 2.69 in group 2, and 17.33 ± 5.04 in group 3. Data were submitted to analysis of variance and the Tukey test. No significant difference were found between groups 1 (37% phosphoric acid) and group 3 (Er:YAG laser + 37% phosphoric acid) but treatment with the Er:YAG laser alone (group 2) resulted in significantly lower tensile bond strength than seen in the other groups. In this setting, the Er:YAG laser prepared the enamel surface for sealing but did not eliminate the need for acid etching before sealant application.
Collapse
Affiliation(s)
- Sima Shahabi
- Laser Research Center in Dentistry (LRCD), Tehran University of Medical Sciences, Tehran, Iran.
| | | | | |
Collapse
|
6
|
Capa N, Aykor A, Ozel E, Calikkocaoglu S, Soyman M. Effect of Er:YAG Laser Irradiations on Shear Bond Strength of Three Self-Adhesive Resin Cements to Dentin. Photomed Laser Surg 2010; 28:809-21. [DOI: 10.1089/pho.2009.2670] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Affiliation(s)
- Nuray Capa
- Department of Prosthodontics, Faculty of Dentistry, Yeditepe University, Istanbul, Turkey
| | - Arzu Aykor
- Department of Operative Dentistry, Faculty of Dentistry, Yeditepe University, Istanbul, Turkey
| | - Emre Ozel
- Department of Operative Dentistry, Faculty of Dentistry, University of Kocaeli, Kocaeli, Turkey
| | - Senih Calikkocaoglu
- Department of Prosthodontics, Faculty of Dentistry, Yeditepe University, Istanbul, Turkey
| | - Mubin Soyman
- Department of Operative Dentistry, Faculty of Dentistry, Yeditepe University, Istanbul, Turkey
| |
Collapse
|
7
|
Cardoso MV, Delmé KI, Mine A, Neves ADA, Coutinho E, De Moor RJ, Van Meerbeek B. Towards a better understanding of the adhesion mechanism of resin-modified glass-ionomers by bonding to differently prepared dentin. J Dent 2010; 38:921-9. [DOI: 10.1016/j.jdent.2010.08.009] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2010] [Revised: 08/12/2010] [Accepted: 08/13/2010] [Indexed: 10/19/2022] Open
|
8
|
Moslemi M, Erfanparast L, Fekrazad R, Tadayon N, Tadayon N, Dadjo H, Shadkar MM, Khalili Z. The effect of Er,Cr:YSGG laser and air abrasion on shear bond strength of a fissure sealant to enamel. J Am Dent Assoc 2010; 141:157-61. [PMID: 20123873 DOI: 10.14219/jada.archive.2010.0133] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE The authors conducted an in vitro study to evaluate the shear bond strength of a fissure sealant to enamel pretreated with erbium,chromium:yttrium, scandium,gallium,garnet (Er,Cr:YSGG) laser or air abrasion followed by acid etching. METHODS The authors sectioned extracted sound premolars mesiodistally and used the buccal and lingual surfaces for experimental analysis. They divided specimens randomly into three groups of 15 each according to the enamel surface pretreatment methods: group A, 37 percent phosphoric acid; group B, air abrasion followed by acid etching with 37 percent phosphoric acid; group C, irradiation with Er,Cr:YSGG laser followed by acid etching with 37 percent phosphoric acid. After applying a bonding system, the authors bonded cylinders of sealant to the enamel surfaces by using transparent gelatin tubes (0.7 millimeter in diameter and 1 mm in height) and then polymerized them. They stored all specimens in distilled water at 37 degrees C for 24 hours. They tested shear bond strength by using a universal testing machine with a crosshead speed of 0.5 mm per second. The authors analyzed the data by means of one-way analysis of variance and Tukey-Kramer post hoc tests (alpha = .05). RESULTS The bond strength of group B specimens was statistically higher than those of group A and group C specimens (P < .05). The authors found no statistically significant differences in shear bond strength between surfaces treated with Er,Cr:YSGG laser and those treated with acid etching alone (P > .05). CONCLUSION Pretreatment of enamel surfaces with air abrasion increased the bond strength of fissure sealant, but pretreatment with Er,Cr:YSGG laser did not increase the effectiveness of conventional acid etching of enamel in sealant bonds.
Collapse
Affiliation(s)
- Masoumeh Moslemi
- Department of Pediatric Dentistry, Dental School, Shahid Beheshti University of Medical Sciences, Evin, Tehran, Iran.
| | | | | | | | | | | | | | | |
Collapse
|
9
|
Korkmaz Y, Ozel E, Attar N, Ozge Bicer C. Influence of different conditioning methods on the shear bond strength of novel light-curing nano-ionomer restorative to enamel and dentin. Lasers Med Sci 2009; 25:861-6. [PMID: 19688586 DOI: 10.1007/s10103-009-0718-8] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2008] [Accepted: 07/15/2009] [Indexed: 11/25/2022]
Abstract
The purpose of this study was to investigate shear bond strength (SBS) between a light-curing nano-ionomer restorative and enamel or dentin after acid etching, after erbium:yttrium-aluminum-garnet (Er:YAG) laser etching, or after combined treatment. Forty third molars were selected, the crowns were sectioned, and 80 tooth slabs were obtained. The specimens were assigned to two groups, which were divided into four subgroups(n = 10). Group 1 [enamel (e)], treated with 37% phosphoric acid (A) + Ketac nano-primer (K); group 2 [dentin (d)], (A) + (K); group 3(e), Er:YAG laser etching (L) + (A) + (K); group 4(d), (L) + (A) + (K); group 5(e), (L) + (K); group 6(d), (L) + (K); group 7(e), (K); group 8(d), (K). The SBS of the specimens was measured with a universal test machine (1 mm/min). Data were analyzed by independent samples t-test, one-way analysis of variance (ANOVA) and a post-hoc Duncan test (p < 0.05). No difference was determined between groups 3 and 5 (p > 0.05). Group 7 exhibited higher SBS values than those of groups 3 and 5 (p < 0.05). Group 1 showed higher SBSs than those of groups 3, 5 and 7 (p < 0.05). There was no significant difference between groups 4 and 6 (p > 0.05). No difference was observed between groups 2 and 4 (p > 0.05). However, group 2 presented higher SBSs than did group 6 (p < 0.05). Group 8 exhibited the highest SBS values when compared with groups 2, 4 and 6 (p < 0.05). Er:YAG laser adversely affected the adhesion of the light-curing nano-ionomer restorative to both enamel and dentin.
Collapse
Affiliation(s)
- Yonca Korkmaz
- Department of Conservative Dentistry, School of Dentistry, Baskent University, 11. Sok. No. 26, Bahcelievler, Ankara, Turkey.
| | | | | | | |
Collapse
|
10
|
Fagundes TC, Toledano M, Navarro MFL, Osorio R. Resistance to degradation of resin-modified glass-ionomer cements dentine bonds. J Dent 2009; 37:342-7. [DOI: 10.1016/j.jdent.2009.01.002] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2008] [Revised: 12/29/2008] [Accepted: 01/06/2009] [Indexed: 11/30/2022] Open
|
11
|
Lepri TP, Souza-Gabriel AE, Atoui JA, Palma-Dibb RG, Pécora JD, Milori Corona SA. Shear bond strength of a sealant to contaminated-enamel surface: influence of erbium : yttrium-aluminum-garnet laser pretreatment. J ESTHET RESTOR DENT 2009; 20:386-92; discussion 393-4. [PMID: 19120785 DOI: 10.1111/j.1708-8240.2008.00214.x] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
BACKGROUND Salivary contamination is one of the factors that can disturb the sealing process and interfere in the longevity of pit and fissure sealants. Erbium : yttrium-aluminum-garnet (Er : YAG) laser could influence the bond strength of enamel and increase the acid resistance. PURPOSE To evaluate the influence of Er : YAG laser on the shear bond strength of a sealant to a salivary contaminated enamel surface. METHODS Twenty-four third molars had the roots sectioned 2 mm coronal to the cementoenamel junction. The crowns were mesiodistally sectioned providing 48 halves that were embedded in polyester resin. Enamel was flattened and a 2-mm diameter bonding area was demarcated. Specimens were randomly assigned to two groups according to the superficial pretreatment-37% phosphoric acid (A) and Er : YAG laser (80 mJ/2 Hz) + phosphoric acid (L), which were subdivided into two groups (N = 12), without salivary contamination (C) and with salivary contamination (SC). To contaminate the specimens, 0.25 mL of human fresh saliva was applied for 20 seconds and then dried. Fluroshield sealant was applied in all specimens. After storage, shear bond strength of samples were tested in a universal testing machine. RESULTS Means in MPa were: AC-14.61 (+/-2.52); ASC-6.66 (+/-2.34); LC-11.91 (+/-1.34); and LSC-2.22 (+/-0.66). Statistical analysis revealed that surfaces without salivary contamination and with acid treatment had the highest mean (p < 0.05). The group with salivary contamination treated by Er : YAG laser followed by phosphoric acid application presented the lowest bond values (p < 0.05). CONCLUSIONS The phosphoric acid etching under dry condition yielded better bonding performance. Er : YAG laser was not able to increase the effectiveness of conventional acid etching of enamel in the bond of sealants in both dry and wet conditions. CLINICAL SIGNIFICANCE Under the conditions of this study, the conventional etching protocol (phosphoric acid without salivary contamination) is still preferable to laser-conditioning enamel surface prior to sealant application.
Collapse
Affiliation(s)
- Taísa Penazzo Lepri
- Department of Restorative Dentistry, Ribeirão Preto School of Dentistry, University of São Paolo (USP), São Paulo, Brazil
| | | | | | | | | | | |
Collapse
|
12
|
Delmé KI, Deman PJ, De Bruyne MA, De Moor RJG. Microleakage of Four Different Restorative Glass Ionomer Formulations in Class V Cavities: Er:YAG Laser versus Conventional Preparation. Photomed Laser Surg 2008; 26:541-9. [DOI: 10.1089/pho.2007.2227] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Affiliation(s)
- Katleen I.M. Delmé
- Department of Operative Dentistry and Endodontology, Ghent Dental Laser Center, Dental School, Ghent University, Gent, Belgium
| | - Peter J. Deman
- Dentist in private practice, Sint-Pieters-Leeuw, Belgium
| | - Mieke A.A. De Bruyne
- Department of Operative Dentistry and Endodontology, Ghent Dental Laser Center, Dental School, Ghent University, Gent, Belgium
| | - Roeland J. G. De Moor
- Department of Operative Dentistry and Endodontology, Ghent Dental Laser Center, Dental School, Ghent University, Gent, Belgium
| |
Collapse
|
13
|
Amaral FLB, Colucci V, Souza-Gabriel AE, Chinelatti MA, Palma-Dibb RG, Corona SAM. Bond durability in erbium:yttrium-aluminum-garnet laser-irradiated enamel. Lasers Med Sci 2008; 25:155-63. [PMID: 18685884 DOI: 10.1007/s10103-008-0593-8] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2008] [Accepted: 06/20/2008] [Indexed: 10/21/2022]
Abstract
This study sought to evaluate the influence of thermocycling and water storage on the microtensile bond strength of composite resin bonded to erbium:yttrium-aluminum-garnet (Er:YAG)-irradiated and bur-prepared enamel. Eighty bovine incisors were selected and sectioned. Specimens were ground to produce a flat enamel surface. Samples were randomly assigned according to cavity preparation device: (I) Er:YAG laser and (II) high-speed turbine, and were subsequently restored with composite resin. They were subdivided according to the duration of water storage (WS)/number of thermocycles (TCs): 24 h WS/no TCs; 7 days WS/500 TCs; 1 month WS/2,000 TCs; 6 months WS/12,000 TCs. The teeth were sectioned into 1.0 mm(2)-thick slabs and subjected to tensile stress in a universal testing machine. Data were submitted to two-way analysis of variance (ANOVA) and Tukey's test at a 0.05 significance level. The different periods of water storage and thermocycling did not influence the microtensile bond strength (microTBS) values in the Er:YAG laser-prepared groups. In bur-prepared enamel, the group submitted to 12,000 TCs/6 months' WS (IID) showed a significant decrease in bond strength values when compared to the group stored in water for 24 h and not submitted to thermocycling (IIA), but values were statistically similar to those obtained in all Er:YAG laser groups and in the bur- prepared groups degraded with 500 TCs/1 week WS (IIB) or 2,000 TCs/1 month WS (IIC). It may be concluded that adhesion of an etch-and-rinse adhesive to Er:YAG laser-irradiated enamel was not affected by the methods used to simulate degradation of the adhesive interface and was similar to adhesion in the bur-prepared groups in all periods of water storage and thermocycling.
Collapse
Affiliation(s)
- F L B Amaral
- Department of Operative Dentistry, Ribeirão Preto School of Dentistry, University of São Paulo (USP), Av. do Café, S/N, Monte Alegre, Ribeirão Preto, 14040-904 São Paulo, Brazi.
| | | | | | | | | | | |
Collapse
|
14
|
Korkmaz Y, Baseren M. Effect of Antibacterial Varnishes Applied to Root Dentin on Shear Bond Strength of Tooth-colored Restorative Materials. Oper Dent 2008; 33:65-71. [DOI: 10.2341/07-38] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/30/2023]
Abstract
Clinical RelevanceThe application of antibacterial varnish affects the shear bond strength of tooth-colored restorative materials after six months.
Collapse
|
15
|
Amaral FLB, Colucci V, Souza-Gabriel AE, Chinelatti MA, Palma-Dibb RG, Corona SAM. Adhesion to Er:YAG Laser-prepared Dentin After Long-term Water Storage and Thermocycling. Oper Dent 2008; 33:51-8. [DOI: 10.2341/07-30] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Clinical Relevance
Simulation of thermal stress and long-term degradation presented in the oral environment adversely affected the adhesion of an etch & rinse adhesive system to Er:YAG laser-irradiated dentin.
Collapse
|
16
|
Jordehi AY, Ghasemi A, Zadeh MM, Fekrazad R. Evaluation of Microtensile Bond Strength of Glass Ionomer Cements to Dentin after Conditioning with the Er,Cr:YSGG Laser. Photomed Laser Surg 2007; 25:402-6. [DOI: 10.1089/pho.2006.2074] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Affiliation(s)
- Atefeh Yousefi Jordehi
- Department of Operative Dentistry, Dental School, Qazvin University of Medical Sciences, Qazvin, Iran
| | - Amir Ghasemi
- Department of Operative Dentistry, Dental School, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Maryam Moezi Zadeh
- Department of Laser, Dental School, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Reza Fekrazad
- Department of Laser, Dental School, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| |
Collapse
|
17
|
Laser Literature Watch. Photomed Laser Surg 2006. [DOI: 10.1089/pho.2006.24.765] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
|