1
|
Carneiro TDS, Favoreto MW, Rodrigues JPF, Sutil E, Centenaro GG, Freitas IDMD, Reis A, García LC, Loguercio AD. In-office dental bleaching in adolescents using 6% hydrogen peroxide with and without gingival barrier: a randomized double-blind clinical trial. J Appl Oral Sci 2024; 32:e20230416. [PMID: 38536995 PMCID: PMC11037928 DOI: 10.1590/1678-7757-2023-0416] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2023] [Revised: 01/19/2024] [Accepted: 01/31/2024] [Indexed: 04/26/2024] Open
Abstract
BACKGROUND At low concentrations used for in-office bleaching gels, such as 6% HP, gingival barrier continues to be performed. If we take into account that, in the at-home bleaching technique, no barrier is indicated, it seems that the use of a gingival barrier fails to make much sense when bleaching gel in low concentration is used for in-office bleaching. OBJECTIVE This double-blind, split-mouth, randomized clinical trial evaluated the gingival irritation (GI) of in-office bleaching using 6% hydrogen peroxide (HP) with and without a gingival barrier in adolescents, as well as color change and the impact of oral condition on quality of life. METHODOLOGY Overall, 60 participants were randomized into which side would or would not receive the gingival barrier. In-office bleaching was performed for 50 minutes with 6% HP in three sessions. The absolute risk and intensity of GI were assessed with a visual analogue scale. Color change was assessed using a digital spectrophotometer and color guides. The impact of oral condition on quality of life was assessed using the Brazilian version of the Oral Health Impact Profile (α=0.05). RESULTS The proportion of patients who presented GI for the "with barrier" group was 31.6% and for the "without barrier" group, 30% (p=1.0). There is an equivalence for the evaluated groups regarding GI intensity (p<0.01). Color change was detected with no statistical differences (p>0.29). There was a significant impact of oral condition on quality of life after bleaching (p<0.001). CONCLUSIONS The use or not of the gingival barrier for in-office bleaching with 6% HP was equivalent for GI, as well as for bleaching efficacy, with improvement in the impact of oral condition on quality of life.
Collapse
Affiliation(s)
- Taynara de Souza Carneiro
- Universidade Estadual de Ponta Grossa, Departamento de Dentística Restauradora, Ponta Grossa, Brasil
- Universidad Rey Juan Carlos, Facultad de Ciencias de la Salud, IDIBO, Madrid, España
| | - Michael Willian Favoreto
- Universidade Estadual de Ponta Grossa, Departamento de Dentística Restauradora, Ponta Grossa, Brasil
| | | | - Elisama Sutil
- Universidade Estadual de Ponta Grossa, Departamento de Dentística Restauradora, Ponta Grossa, Brasil
| | - Gabrielle Gomes Centenaro
- Universidade Estadual de Ponta Grossa, Departamento de Dentística Restauradora, Ponta Grossa, Brasil
| | | | - Alessandra Reis
- Universidade Estadual de Ponta Grossa, Departamento de Dentística Restauradora, Ponta Grossa, Brasil
| | - Laura Ceballos García
- Universidad Rey Juan Carlos, Facultad de Ciencias de la Salud, IDIBO, Madrid, España
| | | |
Collapse
|
2
|
Hortkoff D, da Silva KL, Farago PV, Gomes JC, Reis A, Gomes GM. Effect of topical application of ibuprofen/arginine on the in-office bleaching-induced tooth sensitivity: A randomized, triple-blind controlled trial. J Dent 2024; 142:104875. [PMID: 38309571 DOI: 10.1016/j.jdent.2024.104875] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2023] [Revised: 01/22/2024] [Accepted: 01/31/2024] [Indexed: 02/05/2024] Open
Abstract
OBJECTIVE The application of anti-inflammatories as topical desensitizers before dental bleaching is an approach to reduce bleaching-induced tooth sensitivity (TS). This randomized controlled trial compared the risk and intensity of TS and the color change resulting from in-office dental bleaching after using an experimental desensitizing gel containing ibuprofen and arginine. METHODS Sixty-two participants with upper canine shades A2 or darker were randomly assigned to either the ibuprofen-arginine desensitizing group or the placebo group. The desensitizing gel was applied for 15 min before in-office bleaching with 35 % hydrogen peroxide gel for 50 min (2 sessions). To assess the absolute risk and intensity of TS, visual (0-10) and numeric rating (0-5) scales were used, and group comparisons were made using the McNemar test, Wilcoxon test, and paired Student t-test (α = 0.05). Color change was evaluated using Vita Classical, Vita Bleachedguide (ΔSGU), and Vita EasyShade (ΔEab, ΔE00, and ΔWID) before and one month after the bleaching procedure. Group comparisons for color change were done using a paired t-test (α = 0.05). RESULTS The odds ratio for TS was 0.14 [95 % CI 0.02 to 0.6], meaning lower odds of TS for the desensitizing gel. A lower intensity of TS was also observed for the experimental group (p < 0.005) up to 48 h after bleaching. All color evaluation tools demonstrated effective and similar whitening for both groups (p > 0.05). CONCLUSIONS Using the experimental desensitizing gel containing ibuprofen and arginine effectively reduced the risk and intensity of TS without compromising the bleaching efficacy. CLINICAL RELEVANCE The topical application of ibuprofen/arginine on the in-office bleaching reduced risk and intensity of bleaching-induced tooth sensitivity.
Collapse
Affiliation(s)
- Diego Hortkoff
- Department of Dentistry, State University of Ponta Grossa - UEPG, 4748, Uvaranas - Ponta Grossa, Ponta Grossa, Paraná 84030-900, Brazil
| | - Karine Letícia da Silva
- Department of Dentistry, State University of Ponta Grossa - UEPG, 4748, Uvaranas - Ponta Grossa, Ponta Grossa, Paraná 84030-900, Brazil
| | - Paulo Vitor Farago
- Department of Pharmacy, State University of Ponta Grossa - UEPG, Ponta Grossa, Paraná, Brazil
| | - João Carlos Gomes
- Department of Dentistry, State University of Ponta Grossa - UEPG, 4748, Uvaranas - Ponta Grossa, Ponta Grossa, Paraná 84030-900, Brazil
| | - Alessandra Reis
- Department of Dentistry, State University of Ponta Grossa - UEPG, 4748, Uvaranas - Ponta Grossa, Ponta Grossa, Paraná 84030-900, Brazil
| | - Giovana Mongruel Gomes
- Department of Dentistry, State University of Ponta Grossa - UEPG, 4748, Uvaranas - Ponta Grossa, Ponta Grossa, Paraná 84030-900, Brazil.
| |
Collapse
|
3
|
Carneiro TDS, Favoreto MW, Ferreira MWC, Bernardi LG, Andrade HFD, Bandeca MC, Reis A, Ceballos García L, Loguercio AD. In-office dental bleaching in adolescents using 6% hydrogen peroxide with different application tips: randomized clinical trial. J Appl Oral Sci 2023; 31:e20230216. [PMID: 37909527 PMCID: PMC10609651 DOI: 10.1590/1678-7757-2023-0216] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2023] [Revised: 08/29/2023] [Accepted: 09/12/2023] [Indexed: 11/03/2023] Open
Abstract
OBJECTIVE Despite the availability of in-office bleaching gels with a 6% concentration of hydrogen peroxide (HP), these gels have not been evaluated in younger patients. They are commercially available with a tip, associated or not with a brush, where the tip with a brush spreads the gel over the entire surface to have a smaller thickness (thin layer) since the manufacturers indicate the application of a thin layer of gel. This randomized, split-mouth, double-blind clinical trial evaluated the efficacy of in-office bleaching with 6% HP in adolescents using different application tips, as well tooth sensitivity (TS) and aesthetic self-perception. METHODOLOGY Sixty participants were randomized for 6% HP self-mixing bleaching gel tip design: without brush and with brush. In-office bleaching was performed in 3 sessions of 50 minutes. Color change was evaluated using a digital spectrophotometer (ΔE ab , ΔE 00 , and ΔWI D ) and color guide (ΔSGU), the absolute risk and intensity of TS with a visual analogue scale and aesthetic self-perception with the oral aesthetic scale (a=0.05). RESULTS The groups achieved similar bleaching regardless of the application tip (p>0.05). However, only for ΔWI D , a significant mean difference (MD) was observed in the third week (MD 2.3; 95% CI 1.2 to 3.3; p < 0.001) and at one month (MD 1.6; 95% CI 0.6 to 2.6; p < 0.03) favoring the tip without brush. Regarding TS, 45% in the tip-without-brush group and 33% in the tip-with-brush group reported TS (odds ratio 0.61; 95% CI 0.29 to 1.28; p<0.02), with low TS intensity (MD 0.05; 95% CI -0.06 to 0.17; p>0.36). All patients reported improved aesthetic self-perception after bleaching (MD -1.3; 95% -1.8 to -0.9; p<0.001). CONCLUSIONS Regardless of the tip used bleaching with 6% HP achieved a bleaching efficacy and improved the aesthetic self-perception. However, a lower risk of TS for application using the tip with brush was observed.
Collapse
Affiliation(s)
- Taynara de Souza Carneiro
- Universidade Estadual de Ponta Grossa , Departamento de Dentística Restauradora , Ponta Grossa , Brasil
- Universidad Rey Juan Carlos , Facultad de Ciencias de la Salud , IDIBO, Madrid , España
| | - Michael Willian Favoreto
- Universidade Estadual de Ponta Grossa , Departamento de Dentística Restauradora , Ponta Grossa , Brasil
| | | | - Laís Giacomini Bernardi
- Universidade Estadual de Ponta Grossa , Departamento de Dentística Restauradora , Ponta Grossa , Brasil
| | | | - Matheus Coelho Bandeca
- Universidade Estadual de Ponta Grossa , Departamento de Dentística Restauradora , Ponta Grossa , Brasil
| | - Alessandra Reis
- Universidade Estadual de Ponta Grossa , Departamento de Dentística Restauradora , Ponta Grossa , Brasil
| | - Laura Ceballos García
- Universidad Rey Juan Carlos , Facultad de Ciencias de la Salud , IDIBO, Madrid , España
| | | |
Collapse
|
4
|
Carlos NR, Basting RT, Amaral FLBD, França FMG, Turssi CP, Kantovitz KR, Bronze-Uhle ES, Lisboa Filho PN, Cavalli V, Basting RT. Physicochemical evaluation of hydrogen peroxide bleaching gels containing titanium dioxide catalytic agent, and their influence on dental color change associated with violet LED. Photodiagnosis Photodyn Ther 2022; 41:103254. [PMID: 36572111 DOI: 10.1016/j.pdpdt.2022.103254] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2022] [Revised: 12/14/2022] [Accepted: 12/21/2022] [Indexed: 12/24/2022]
Abstract
BACKGROUND The purpose of this study was: 1) to analyze the physical-chemical properties of hydrogen peroxide (HP) agents at 7.5% (HP7) and 35% (HP35), and the association with or without TiO2 nanotubes; 2) to evaluate dental bleaching effectiveness by using HP7 and HP35 together with or without TiO2 nanotubes, and applied with or without violet LED (VL). METHODOLOGY 80 bovine incisors were treated according to groups (n = 10): HP35; HP35 + VL; HP35T (HP35 + TiO2); HP35T + VL; HP7; HP7 + VL; HP7T (HP7 + TiO2); HP7T + VL. Bleaching effectiveness was measured at 4 time points according to the Vita Classical, CIEL*a*b*, CIEDE2000, and WID parameters. HP35, HP35T, HP7, and HP7T were evaluated for mass change, pH, mean particle size (P), polydispersity (PDI), and zeta potential (ZP), over 6 months of storage. RESULTS The pH of HP35 thickener was higher when associated to TiO2. At baseline, both of the bleaching gels containing TiO2 had lower P, PDI, and PZ (p < 0.05). All groups showed a significant decrease in Vita Classical color scores (p = 0.0037). There was a higher L* value, and lower b* values for HP7 when associated to VL after the 3rd session. (p < 0.05). HP35T showed higher color change (ΔEab, ΔE00), and lower a* value in the presence of VL (p < 0.05). ΔWID presented lower values for both gels, when TiO2 was incorporated (p ≤ 0.05). CONCLUSION The incorporation of TiO2 to the bleaching gel showed good stability with minimal variations in physical-chemical properties. The color change in HP35 was more effective than in HP7, but the VL boosted the bleaching effectiveness of HP7, whereas TiO2 did not increase bleaching effectiveness.
Collapse
Affiliation(s)
- Natália Russo Carlos
- Faculdade São Leopoldo Mandic, Rua José Rocha Junqueira 13, Bairro Swift, Campinas, CEP: 13045-755, São Paulo, Brazil
| | - Rosanna Tarkany Basting
- Faculdade São Leopoldo Mandic, Rua José Rocha Junqueira 13, Bairro Swift, Campinas, CEP: 13045-755, São Paulo, Brazil
| | | | | | - Cecilia Pedroso Turssi
- Faculdade São Leopoldo Mandic, Rua José Rocha Junqueira 13, Bairro Swift, Campinas, CEP: 13045-755, São Paulo, Brazil
| | - Kamila Rosamilia Kantovitz
- Faculdade São Leopoldo Mandic, Rua José Rocha Junqueira 13, Bairro Swift, Campinas, CEP: 13045-755, São Paulo, Brazil
| | - Erika Soares Bronze-Uhle
- São Paulo State University (UNESP), School of Sciences, Av. Eng. Luís Edmundo Carrijo Coube, 2085, Nucleo Res. Pres. Geisel, Bauru, CEP: 17033-360, São Paulo, Brazil
| | - Paulo Noronha Lisboa Filho
- São Paulo State University (UNESP), School of Sciences, Av. Eng. Luís Edmundo Carrijo Coube, 2085, Nucleo Res. Pres. Geisel, Bauru, CEP: 17033-360, São Paulo, Brazil
| | - Vanessa Cavalli
- Piracicaba Dental School, University of Campinas, 901 Limeira Avenue, Areião, 13414-903, Piracicaba, São Paulo, Brazil
| | - Roberta Tarkany Basting
- Faculdade São Leopoldo Mandic, Rua José Rocha Junqueira 13, Bairro Swift, Campinas, CEP: 13045-755, São Paulo, Brazil.
| |
Collapse
|
5
|
Manzoli TM, Costa JLDSG, Besegato JF, Gelio MB, Galvani LD, Bordini EAF, Kuga MC, Dantas AAR. Violet LED associated with high concentration hydrogen peroxide: Effects on bleaching efficacy, pH, and temperature. Photodiagnosis Photodyn Ther 2022; 40:103133. [PMID: 36162757 DOI: 10.1016/j.pdpdt.2022.103133] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2022] [Revised: 09/13/2022] [Accepted: 09/21/2022] [Indexed: 12/14/2022]
Abstract
BACKGROUND This study aimed to evaluate the bleaching efficacy, pH, and temperature of 35% hydrogen peroxide (HP) gel used alone or associated with violet LED. METHODS Sixty bovine crowns were sectioned (5 × 5 × 2mm). After staining with black tea, the specimens were randomized into four groups (n = 10) according to the bleaching protocol: HP35R: 3 × 15 min 35% HP; HP35: 1 × 45 min 35% HP; HP35VR: 3 × 8min 35% HP + Violet LED; HP35V: 1 × 24 min + Violet LED. Two bleaching sessions were performed for all the groups. Color change was evaluated before, 24h after each session, 7 days and 15 days after the last session. The variables ∆E00 [CIEDE2000] and WID were used for color analysis. The pH variation (initial and final) and the temperature of the gel were recorded (n = 5). ANOVA two-way for repeated measures and Bonferroni post-test was used at a significance level of 5%. RESULTS HP35VR and HP35V the most noticeable color change(p < 0.05). The final values of pH were lower than the initial ones, but with no difference between the groups (p > 0.05). Groups HP35VR and HP35V showed an increase in temperature in relation to HP35R (p < 0.05). CONCLUSIONS Violet LED improved the bleaching efficacy of 35% HP in a time-saving manner without negatively affecting the pH and temperature of 35% HP. The renewal of HP did not influence the outcomes.
Collapse
Affiliation(s)
- Tatiane Miranda Manzoli
- Department of Restorative Dentistry, School of Dentistry, Araraquara, São Paulo State University - UNESP, 1680 Humaitá Street - 3rd floor, Centro, Mail Box: 331, ZIP Code 14801-903, Araraquara, São Paulo, Brazil.
| | - Joatan Lucas de Sousa Gomes Costa
- Department of Restorative Dentistry, School of Dentistry, Araraquara, São Paulo State University - UNESP, 1680 Humaitá Street - 3rd floor, Centro, Mail Box: 331, ZIP Code 14801-903, Araraquara, São Paulo, Brazil.
| | - João Felipe Besegato
- Department of Restorative Dentistry, School of Dentistry, Araraquara, São Paulo State University - UNESP, 1680 Humaitá Street - 3rd floor, Centro, Mail Box: 331, ZIP Code 14801-903, Araraquara, São Paulo, Brazil.
| | - Mariana Bena Gelio
- Department of Restorative Dentistry, School of Dentistry, Araraquara, São Paulo State University - UNESP, 1680 Humaitá Street - 3rd floor, Centro, Mail Box: 331, ZIP Code 14801-903, Araraquara, São Paulo, Brazil.
| | - Lucas David Galvani
- Department of Restorative Dentistry, School of Dentistry, Araraquara, São Paulo State University - UNESP, 1680 Humaitá Street - 3rd floor, Centro, Mail Box: 331, ZIP Code 14801-903, Araraquara, São Paulo, Brazil.
| | - Ester Alves Ferreira Bordini
- Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo - USP, Alameda Dr. Octávio Pinheiro Brisolla, 9-75, ZIP Code 17012-901, Bauru, São Paulo, Brazil.
| | - Milton Carlos Kuga
- Department of Restorative Dentistry, School of Dentistry, Araraquara, São Paulo State University - UNESP, 1680 Humaitá Street - 3rd floor, Centro, Mail Box: 331, ZIP Code 14801-903, Araraquara, São Paulo, Brazil.
| | - Andréa Abi Rached Dantas
- Department of Restorative Dentistry, School of Dentistry, Araraquara, São Paulo State University - UNESP, 1680 Humaitá Street - 3rd floor, Centro, Mail Box: 331, ZIP Code 14801-903, Araraquara, São Paulo, Brazil.
| |
Collapse
|
6
|
Costa JLDSG, Nogueira BR, Batista de Oliveira Junior O, Pretel H. The influence of hydrogen peroxide concentration on the chemical kinetics of photo-accelerated tooth whitening. Photodiagnosis Photodyn Ther 2022; 40:103175. [PMID: 36332894 DOI: 10.1016/j.pdpdt.2022.103175] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2022] [Revised: 09/20/2022] [Accepted: 09/21/2022] [Indexed: 11/11/2022]
Abstract
BACKGROUND The bleaching procedure consists of chemical principles of free radical release that react with chromophores, which results in an amount of energy released in this process. However, the evaluation of the electrical potential generated in these protocols has not yet been thoroughly investigated in the literature. Thus, this study aimed to examine variations in pH, mV, and temperature of different concentrations of hydrogen peroxide in the presence or absence of an intermittent LED/LASER photo acceleration system. METHODS The study was divided into six groups (n = 9) according to the concentration of hydrogen peroxide (6%, 15%, and 35%), associated or not with the photo acceleration system LED/LASER. We followed the variation of pH, mV, and temperature at 1, 5, 10, 15, and 30 min after gel manipulation. Data were evaluated by two-way ANOVA of repeated measures (α =0.05). RESULTS pH, mV, and temperature of the groups showed statistical differences both in the light and bleach and in the interaction between the two factors (p < 0.0001), where pH and mV were more influenced by the bleach and light factor, while the temperature was influenced by the bleach factor associated with light. HP15 presented the most significant change in pH, mV, and temperature. CONCLUSION The use of LED/laser increased the temperature of the gels and altered the pH and mV kinetics of HP6 and HP15, which did not occur in HP35, possibly due to the high ionic potential linked to the concentration.
Collapse
Affiliation(s)
- Joatan Lucas de Sousa Gomes Costa
- Department of Restorative Dentistry, School of Dentistry, São Paulo State University - UNESP, 3rd floor, Humaitá Street, 1680 - Centro, Mail Box: 331, Araraquara, São Paulo 14801-903, Brazil
| | - Básia Rabelo Nogueira
- Department of Restorative Dentistry, School of Dentistry, São Paulo State University - UNESP, 3rd floor, Humaitá Street, 1680 - Centro, Mail Box: 331, Araraquara, São Paulo 14801-903, Brazil
| | - Osmir Batista de Oliveira Junior
- Department of Restorative Dentistry, School of Dentistry, São Paulo State University - UNESP, 3rd floor, Humaitá Street, 1680 - Centro, Mail Box: 331, Araraquara, São Paulo 14801-903, Brazil
| | - Hermes Pretel
- Department of Restorative Dentistry, School of Dentistry, São Paulo State University - UNESP, 3rd floor, Humaitá Street, 1680 - Centro, Mail Box: 331, Araraquara, São Paulo 14801-903, Brazil.
| |
Collapse
|
7
|
Costa JLDSG, Besegato JF, Zaniboni JF, Galvani LD, Kuga MC. Effects of tooth bleaching protocols with violet LED and hydrogen peroxide on enamel properties. Photodiagnosis Photodyn Ther 2022; 38:102733. [PMID: 35065278 DOI: 10.1016/j.pdpdt.2022.102733] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2021] [Revised: 01/13/2022] [Accepted: 01/18/2022] [Indexed: 11/19/2022]
Abstract
BACKGROUND This study evaluated the color change, enamel surface roughness and microhardness after different tooth bleaching protocols, using hydrogen peroxide (HP) and/or violet LED. METHODS Forty bovine specimens (7 × 7 × 2 mm) were randomly distributed into 4 groups: 35% HP, 6% HP, 6% HP + violet LED and violet LED alone. First, the specimens were stained with black tea and then submitted to two bleaching sessions of 30 min with an interval of 7 days. Color change (∆L*, ∆a*, ∆b* and ∆E00) after 24 h of each session and 1 week after the last session was evaluated. Enamel roughness and microhardness were evaluated immediately before the sessions, 24 h and 1 week after the last session. Data were evaluated by ANOVA for repeated measures and Bonferroni post-test or Kruskall-Wallis and Dunn tests (α = 0.05). Representative specimens from each group were analyzed by scanning electron microscopy. RESULTS 6% HP + violet LED and 35% HP showed the highest color change, while violet LED alone had the lowest results. Enamel roughness analyses showed that 6% HP + violet LED and 35% HP showed changes after two bleaching sessions. No differences were observed regarding enamel microhardness. CONCLUSIONS The use of 6% HP + violet LED showed enhanced bleaching efficacy compared to 35% HP. However, violet LED used alone exhibited the lowest color change. 6% HP + violet LED and 35% HP promoted changes on enamel roughness, while no microhardness changes was observed for any group.
Collapse
Affiliation(s)
- Joatan Lucas de Sousa Gomes Costa
- Department of Restorative Dentistry, School of Dentistry, Araraquara, São Paulo State University - UNESP, 1680 Humaitá Street, 3rd floor - Centro, Mail Box: 331, Araraquara, SP, Zip Code 14801-903, Brazil.
| | - João Felipe Besegato
- Department of Restorative Dentistry, School of Dentistry, Araraquara, São Paulo State University - UNESP, 1680 Humaitá Street, 3rd floor - Centro, Mail Box: 331, Araraquara, SP, Zip Code 14801-903, Brazil.
| | - Joissi Ferrari Zaniboni
- Department of Restorative Dentistry, School of Dentistry, Araraquara, São Paulo State University - UNESP, 1680 Humaitá Street, 3rd floor - Centro, Mail Box: 331, Araraquara, SP, Zip Code 14801-903, Brazil.
| | - Lucas David Galvani
- Department of Restorative Dentistry, School of Dentistry, Araraquara, São Paulo State University - UNESP, 1680 Humaitá Street, 3rd floor - Centro, Mail Box: 331, Araraquara, SP, Zip Code 14801-903, Brazil.
| | - Milton Carlos Kuga
- Department of Restorative Dentistry, School of Dentistry, Araraquara, São Paulo State University - UNESP, 1680 Humaitá Street, 3rd floor - Centro, Mail Box: 331, Araraquara, SP, Zip Code 14801-903, Brazil.
| |
Collapse
|
8
|
Trevisan TC, Bortolatto JF, Rizzi G, Meloto BT, Dantas AAR, de Oliveira Junior OB. Clinical performance of 6% hydrogen peroxide containing TiO 2N nanoparticles activated by LED in varying wavelengths-a randomized clinical trial. Lasers Med Sci 2021; 37:2017-2024. [PMID: 34778937 DOI: 10.1007/s10103-021-03464-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2021] [Accepted: 11/05/2021] [Indexed: 11/22/2022]
Abstract
This randomized, controlled, and double-blinded clinical trial evaluated the clinical performance of dental bleaching performed with 6% hydrogen peroxide containing TiO2-N nanoparticles exposed to blue and violet activation lights. Forty volunteers, selected according to the inclusion and exclusion criteria, were randomly distributed into four experimental groups (n = 10): 35% hydrogen peroxide (PH35)-control; 6% hydrogen peroxide (PH6) containing TiO2-N nanoparticles without light activation; PH6 activated with a blue LED (PH6A); and PH6 activated with a violet LED (PH6V). The three bleaching sessions consisted of 3 consecutive 16-min applications of the bleaching agent described for each group. The groups receiving LED activation were exposed to light intermittently every 1 min, with a total exposure time of 8 min in each application. Efficacy was determined by the color variation in the upper central incisors and canines, using reflectance spectroscopy analysis performed by a calibrated evaluator (ICC = 0.83). Tooth sensitivity was characterized according to the presence and intensity (SI) self-recorded in specific forms. The group treated with PH6V was as effective as the control group (PH35), whereas the groups PH6A and PH6 showed lower efficacy. Regardless of the activation, all groups treated with 6% hydrogen peroxide were less likely to cause sensitivity compared to the control group (PH35). The use pf PH6 activated by LED violet resulted in an effective and safe clinical protocol for in-office dental bleaching.Trial registration number: RBR-8pbydg; registration date: 08/29/2017.
Collapse
Affiliation(s)
- Tamara Carolina Trevisan
- Department of Restorative Dentistry, Araraquara School of Dentistry, UNESP - Univ, Estadual Paulista, Araraquara, 14801-903, Brazil.
| | - Janaina Freitas Bortolatto
- Department of Restorative Dentistry, Araraquara School of Dentistry, UNESP - Univ, Estadual Paulista, Araraquara, 14801-903, Brazil
| | - Giovana Rizzi
- Department of Restorative Dentistry, Araraquara School of Dentistry, UNESP - Univ, Estadual Paulista, Araraquara, 14801-903, Brazil
| | - Bruna Tavoni Meloto
- Department of Restorative Dentistry, Araraquara School of Dentistry, UNESP - Univ, Estadual Paulista, Araraquara, 14801-903, Brazil
| | - Andrea Abi Rached Dantas
- Department of Restorative Dentistry, Araraquara School of Dentistry, UNESP - Univ, Estadual Paulista, Araraquara, 14801-903, Brazil
| | - Osmir Batista de Oliveira Junior
- Department of Restorative Dentistry, Araraquara School of Dentistry, UNESP - Univ, Estadual Paulista, Araraquara, 14801-903, Brazil
| |
Collapse
|
9
|
Kury M, Lins RBE, Resende BDA, Picolo MZD, André CB, Cavalli V. The influence of the renewal or the single application of the peroxide gel on the efficacy and tooth sensitivity outcomes of in-office bleaching-A systematic review and meta-analysis. J ESTHET RESTOR DENT 2021; 34:490-502. [PMID: 34623017 DOI: 10.1111/jerd.12827] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2021] [Revised: 09/22/2021] [Accepted: 09/26/2021] [Indexed: 01/14/2023]
Abstract
OBJECTIVE To answer the question: "Does the peroxide gel application regimen (single application vs. renewal) influence the efficacy and the tooth sensitivity outcomes of in-office tooth bleaching?" METHODS The search was done in Pubmed, Cochrane, LILACS, Scopus, Web of Science, and EMBASE in February 2021 (updated in July 2021). Randomized clinical trials (RCT) comparing the single application vs. the renewal protocols of HP were included. The meta-analyses were performed for the objective (ΔEab ), subjective (ΔSGU) color changes, and absolute risk of tooth sensitivity (TS). Heterogeneity was evaluated using Q test (I2 ). Cochrane Collaboration tool assessed the risk of bias (RoB). The GRADE evaluated the certainty of evidence. RESULTS Five RCT studies remained. Two studies showed high RoB, and three presented some concerns. No significant differences were observed between the protocols in terms of the ΔEab , ΔSGU, and TS. ΔEab exhibited substantial heterogeneity (I2 = 87%), while ΔSGU (I2 = 60%) and the TS (I2 = 62%) presented a moderate one. The certainty of evidence was considered low or very low, depending on the variable response and the evaluation time. CONCLUSION The application regimen (single vs. renewal of HP) did not impact color change or the absolute risk of TS. CLINICAL SIGNIFICANCE The renewal of bleaching gel during the in-office appointment may not be necessary. However, there is at least a low certainty of evidence. Because of this, further randomized clinical trials with appropriate methodology on this topic are encouraged.
Collapse
Affiliation(s)
- Matheus Kury
- Department of Restorative Dentistry, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil
| | - Rodrigo Barros Esteves Lins
- Department of Restorative Dentistry, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil
| | - Bruna de Almeida Resende
- Department of Restorative Dentistry, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil
| | - Mayara Zaghi Dal Picolo
- Department of Restorative Dentistry, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil
| | - Carolina Bosso André
- Department of Restorative Dentistry, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil.,Department of Restorative Dentistry, Dental School, Federal University of Minas Gerais, Belo Horizonte, MG, Brazil
| | - Vanessa Cavalli
- Department of Restorative Dentistry, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil
| |
Collapse
|
10
|
Bersezio C, Pardo C, Miranda S, Medeiros Maran B, Jorquera G, Rosa da Silva A, Tonetto Rodrigues M, Fernández E. Evaluation of the effectiveness in teeth whitening of a single session with 6% hydrogen peroxide Laser/LED system. Photodiagnosis Photodyn Ther 2021; 36:102532. [PMID: 34520881 DOI: 10.1016/j.pdpdt.2021.102532] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2021] [Revised: 08/26/2021] [Accepted: 09/10/2021] [Indexed: 10/20/2022]
Abstract
BACKGROUND Due to the current importance of dental whitening, multiple studies have been carried out in order to achieve an efficient, effective, and innocuous procedure. This study aimed to compare the effectiveness and sensitivity of in-office dental bleaching with one versus two applications of 6% hydrogen peroxide (HP) gel with nitrogen titanium dioxide (TiO2) nanoparticles activated by LED/Laser lamp in a single-session. METHODS This RCT with a split-mouth design was performed in twenty-seven volunteers. The in-office dental bleaching technique was performed using 6% HP with nitrogen TiO2 nanoparticles. In each patient, groups were randomized by hemiarch: Group 1 received one application of 72 minutes and Group 2 received two applications of 36 minutes, both groups in a single-session. RESULTS There were no significant differences in the effectiveness of a single-session with one or two applications of 6% HP with nitrogen TiO2 nanoparticles between both groups(p>0.05). A positive and increase of ∆E value was observed in both groups. Group 1 showed an increase of 4.45 in the immediate measurement, remaining at 4.41 until the one-week control, to increase up to an ∆E of 4.99 at one-month control. Group 2 showed a sustained increase of 4.02 units in the immediate control until reaching the maximum value of 5.46 units of ∆E at one-month control. CONCLUSION One session single application protocol of 6% Hydrogen Peroxide gel with nanoparticulate TiO2 activated by LED/Laser is effective and efficient for dental bleaching.
Collapse
Affiliation(s)
- Cristian Bersezio
- Restorative Dentistry Departament, Faculty of Dentistry, University of Chile.
| | - Carolina Pardo
- PhD program, Faculty of Dentistry, University of Chile, Chile; Faculty of Dentistry, Universidad de Los Andes, Santiago, Chile; Universidad de Valparaíso, Faculty of Dentistry, Valparaíso, Chile..
| | - Scarlet Miranda
- Restorative Dentistry Departament, Faculty of Dentistry, University of Chile.
| | - Bianca Medeiros Maran
- Universidad de Valparaíso, Faculty of Dentistry, Valparaíso, Chile.; Department of Restorative Dentistry, School of Dentistry, State University of Western Paraná, Cascavel, PR, Brazil.
| | - Gilbert Jorquera
- Department of Prosthodontics, College of Dentistry, Universidad de Los Andes, Santiago, Chile.
| | | | | | - Eduardo Fernández
- Restorative Dentistry Departament, Faculty of Dentistry, University of Chile; Instituto de Ciencias Biomédicas, Universidad Autónoma de Chile, Chile.
| |
Collapse
|
11
|
Costa JLDSG, Besegato JF, Zaniboni JF, Kuga MC. LED/laser photoactivation enhances the whitening efficacy of low concentration hydrogen peroxide without microstructural enamel changes. Photodiagnosis Photodyn Ther 2021; 36:102511. [PMID: 34469795 DOI: 10.1016/j.pdpdt.2021.102511] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2021] [Accepted: 08/27/2021] [Indexed: 10/20/2022]
Abstract
BACKGROUND The association of low concentration hydrogen peroxide (HP) and a light source has been widely used to achieve efficient bleaching. We investigated the colorimetric and microstructural changes of bovine enamel bleached with 6% HP associated or not with a hybrid light source system of violet light and laser (LED/laser). METHODS Twenty bovine crowns were used to obtain specimens of 7 × 7 × 2 mm. Then, they were randomized in two groups (n=10): 6% HP and 6% HP + LED/laser. After staining with dark tea solution, three bleaching sessions were performed. Colorimetric evaluation (∆L*, ∆a*, ∆b*, ∆E00 [CIEDE2000] and WID) after 24 hours of each session and 7 days after the final bleaching session was performed. Enamel Vickers microhardness at baseline, 24 hours and 7 days after the last bleaching session were also evaluated. Two-way repeated measures ANOVA and Bonferroni post-test was used at a significance level of 5%. RESULTS 6% HP and 6% + HP LED/laser showed satisfactory bleaching results. The group photoactivated showed higher WID values (p<0.05). Differences between groups were observed for ∆E00, ∆L* and ∆a* (p<0.05), except for ∆b* (p>0.05). Intra-group differences were also found (p<0.05). Regarding microhardness, no inter or intra-group differences were observed (p>0.05). CONCLUSIONS The photoactivation with LED/laser enhanced the whitening efficacy of 6% HP compared to the group without photoactivation. Thus, the LED/laser activation appears to be a good option when using low concentration HP-based agents. In addition, both bleaching protocols did not cause changes on enamel microhardness.
Collapse
Affiliation(s)
- Joatan Lucas de Sousa Gomes Costa
- Department of Restorative Dentistry, School of Dentistry, Araraquara, São Paulo State University - UNESP, 3rd floor, Humaitá Street, 1680 - Centro, Mail Box: 331, Araraquara, São Paulo 14801-903, Brazil.
| | - João Felipe Besegato
- Department of Restorative Dentistry, School of Dentistry, Araraquara, São Paulo State University - UNESP, 3rd floor, Humaitá Street, 1680 - Centro, Mail Box: 331, Araraquara, São Paulo 14801-903, Brazil.
| | - Joissi Ferrari Zaniboni
- Department of Restorative Dentistry, School of Dentistry, Araraquara, São Paulo State University - UNESP, 3rd floor, Humaitá Street, 1680 - Centro, Mail Box: 331, Araraquara, São Paulo 14801-903, Brazil.
| | - Milton Carlos Kuga
- Department of Restorative Dentistry, School of Dentistry, Araraquara, São Paulo State University - UNESP, 3rd floor, Humaitá Street, 1680 - Centro, Mail Box: 331, Araraquara, São Paulo 14801-903, Brazil.
| |
Collapse
|
12
|
Youssef SA, Cunha SR, Mayer-Santos E, Brito SA, de Freitas PM, Ramalho J, Morimoto S, Gonçalves F, Ramalho KM. Influence of 35% hydrogen peroxide gel renewal on color change during in-office dental photobleaching with violet LED: A split-mouth randomized controlled clinical trial. Photodiagnosis Photodyn Ther 2021; 36:102509. [PMID: 34455106 DOI: 10.1016/j.pdpdt.2021.102509] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2021] [Revised: 08/22/2021] [Accepted: 08/24/2021] [Indexed: 11/27/2022]
Abstract
BACKGROUND To clinically evaluate the effect of 35% hydrogen peroxide gel renewal in association with violet LED (405-410nm) through a split-mouth randomized controlled clinical trial. METHODS The treatment consisted in 3 bleaching sessions of 15 min each, with an interval of 7 days between them, using 35% hydrogen peroxide combined to violet LED irradiation. Selected patients had two experimental segments for the split-mouth design: No change of the bleaching gel during each session (NBGR) and 3 changes of the bleaching gel every 5 min for each session (BGR). During the 3 bleaching sessions, the selected quadrant received the same treatment. Patients had their upper canines and central incisors teeth color measured with a subjective (color scale - VITA Classical) and an objective (spectrophotometer - VITA Easyshade) method and their teeth sensitivity measured using a Visual Analog Scale (VAS) before, immediately after each bleaching session, and 14 days and 2 months (60 days) after the end of the treatment. RESULTS The protocol adopted in the present study reached satisfactory results regarding color change. No statistical difference between groups was observed immediately after the end of the treatment and in the follow-up analysis for both subjective and objective color evaluation. No difference in tooth sensitivity between segments was observed. CONCLUSION There is no need for bleaching gel renewal when following the clinical protocol of 3 sessions of 15 min in a bleaching protocol of 35% hydrogen peroxide combined with violet LED.
Collapse
Affiliation(s)
- Shady A Youssef
- Universidade Ibirapuera, Av. Interlagos, 1329, São Paulo, SP 04661-100, Brazil
| | - Sandra Ribeiro Cunha
- College of Dentistry, University of Iowa, 801 Newton Road, Iowa City, IA, United States
| | - Eric Mayer-Santos
- Laboratório Especial de Laser em Odontologia (LELO), Universidade de São Paulo, Faculdade de Odontologia, Av. Professor Lineu Prestes, 2227, São Paulo, SP, Brazil
| | - Sara Alves Brito
- Universidade Ibirapuera, Av. Interlagos, 1329, São Paulo, SP 04661-100, Brazil
| | - Patrícia Moreira de Freitas
- Laboratório Especial de Laser em Odontologia (LELO), Universidade de São Paulo, Faculdade de Odontologia, Av. Professor Lineu Prestes, 2227, São Paulo, SP, Brazil
| | - Juliana Ramalho
- Universidade Ibirapuera, Av. Interlagos, 1329, São Paulo, SP 04661-100, Brazil
| | - Susana Morimoto
- Universidade Ibirapuera, Av. Interlagos, 1329, São Paulo, SP 04661-100, Brazil
| | - Flavia Gonçalves
- Universidade Ibirapuera, Av. Interlagos, 1329, São Paulo, SP 04661-100, Brazil
| | | |
Collapse
|
13
|
In-office bleaching protocols using violet LED: A split mouth case report. Photodiagnosis Photodyn Ther 2021; 36:102497. [PMID: 34428577 DOI: 10.1016/j.pdpdt.2021.102497] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2021] [Revised: 04/22/2021] [Accepted: 08/19/2021] [Indexed: 11/20/2022]
Abstract
A new LED wavelength, violet LED (VL) with a wavelength between 405 - 410 nm was recently introduced to be used for in-office dental bleaching. In comparison to the blue LED system (440 to 485 nm), the shorter wavelength has more energy carried in its photons and also corresponds to the absorption peak of the stained particles, which lead to whitening utilizing a physical process. Considering the need to suggest and develop new protocols with this new technology, this article reports 2 different dental bleaching protocols developed in a split-mouth model using VL. A 25-year-old male patient was submitted to in-office dental bleaching. On the teeth from the left side, the bleaching gel (35% H2O2) was renewed 3 times (every 8 mins), and on the right side, the gel was maintained without renewal during the bleaching session. The irradiation with Violet LED Light (405 nm ± 10 nm) was performed with the following protocol: 1 min of irradiation with 30 s light off until 8 min of total time. A total of 3 cycles were performed (total time of 24 min). Two bleaching sessions were performed with an interval of 7 days between sessions. Based on the results of this split-mouth case report, there was no visible difference in the final color outcome and sensitivity between both bleaching protocols tested.
Collapse
|
14
|
Costa JLDSG, Besegato JF, Kuga MC. Bleaching and microstructural effects of low concentration hydrogen peroxide photoactivated with LED/laser system on bovine enamel. Photodiagnosis Photodyn Ther 2021; 35:102352. [PMID: 34051345 DOI: 10.1016/j.pdpdt.2021.102352] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2021] [Revised: 05/14/2021] [Accepted: 05/21/2021] [Indexed: 11/30/2022]
Abstract
BACKGROUND Tooth whitening protocols with low concentration hydrogen peroxide (HP) appear to minimize the microstructural effect on teeth. In addition, light sources have been used to enhance bleaching efficiency. This study evaluated the color change and microhardness of a protocol with 6% HP photoactivated by LED/laser in comparison with 35% HP. METHODS Twenty bovine incisors were randomized in two groups: 6% HP + LED/laser and 35% HP (n=10). Teeth were submitted to staining using dark tea. Three whitening sessions were carried out according to the manufacturer's instructions. Enamel microhardness (VHN) and color change evaluation (∆L*, ∆a*, ∆b*, ∆E00 [CIEDE2000], and WID) before 24 hours and 7 days after the last whitening session were performed. Two-way repeated ANOVA and Bonferroni post-test was used (α = 0.05). RESULTS Both groups showed perceptible color changes, being more pronounce for 35% HP. Differences were observed for ∆a*, ∆b* and ∆E00 (p≤0.027), except for ∆L* (p>0.05). Differences were also found in the comparison among the evaluation times within the same group (p≤0.027), except for ∆a* results (p>0.05). WID showed that 35% HP exhibited high whiteness values. Regarding microhardness, the groups did not show significant differences (p>0.05). However, 35% HP showed decreased values after 7 days of the last whitening session compared to the baseline (p≤0.027). CONCLUSIONS 6% HP + LED/laser promoted perceptible color change, but not comparable with 35% HP. No differences on enamel microhardness were observed between the whitening protocols. However, 35% HP showed decreased hardness after 7 days of whitening compared to baseline.
Collapse
Affiliation(s)
- Joatan Lucas de Sousa Gomes Costa
- Department of Restorative Dentistry, School of Dentistry, Araraquara, São Paulo State University - UNESP, Araraquara, São Paulo 14801-903, Brazil.
| | - João Felipe Besegato
- Department of Restorative Dentistry, School of Dentistry, Araraquara, São Paulo State University - UNESP, Araraquara, São Paulo 14801-903, Brazil.
| | - Milton Carlos Kuga
- Department of Restorative Dentistry, School of Dentistry, Araraquara, São Paulo State University - UNESP, Araraquara, São Paulo 14801-903, Brazil.
| |
Collapse
|
15
|
Costa JLDSG, Nogueira BR, de Oliveira Junior OB, Pretel H. Association of microabrasion and tooth whitening with LED/laser system in the treatment of incisor hypomineralization: 3-year follow-up. Photodiagnosis Photodyn Ther 2021; 33:102197. [PMID: 33515762 DOI: 10.1016/j.pdpdt.2021.102197] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2020] [Revised: 01/11/2021] [Accepted: 01/22/2021] [Indexed: 10/22/2022]
Abstract
The hypomineralization of enamel is characterized as a defect in the quality of the enamel during the maturation process. This presents with clinical consequence as a whitish and rough appearance that effects the aesthetics of the dental elements. In recent years there has been a significant increase in this pathology, which has led to a great demand from professionals in the search for knowledge and appropriate technique to treat cases. Minimally invasive therapy may be sufficient for the aesthetic return of the altered enamel. Thus, the present clinical case aimed to present an aesthetic treatment of enamel hypomineralization in the upper incisors with a minimally invasive approach of association of microabrasion with low concentration tooth whitening photoaccelerated by violet LED and infrared laser. The follow-up of the case was performed for 3 years and the association of the techniques proved effective in returning the aesthetics and well-being of the patient, appearing as a good conservative alternative for the treatment of enamel hypomineralization.
Collapse
Affiliation(s)
| | - Básia Rabelo Nogueira
- Department of Restorative Dentistry, Araraquara School of Dentistry, São Paulo State University, UNESP, Araraquara, SP, Brazil.
| | | | - Hermes Pretel
- Department of Restorative Dentistry, Araraquara School of Dentistry, São Paulo State University, UNESP, Araraquara, SP, Brazil.
| |
Collapse
|
16
|
Estay J, Angel P, Bersezio C, Tonetto M, Jorquera G, Peña M, Fernández E. The change of teeth color, whiteness variations and its psychosocial and self-perception effects when using low vs. high concentration bleaching gels: a one-year follow-up. BMC Oral Health 2020; 20:255. [PMID: 32917192 PMCID: PMC7488418 DOI: 10.1186/s12903-020-01244-x] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2019] [Accepted: 09/02/2020] [Indexed: 11/29/2022] Open
Abstract
Background Dental bleaching in traditional concentrations generates greater sensitivity. In this respect, new systems of lower concentration of hydrogen peroxide for tooth bleaching appeared, with color stability unknown over time. The aim of this study was to compare the change and stability of color with low-concentration (6%) hydrogen peroxide gel in an in-office bleaching setting relative to conventional 37.5% gel, including their effects on psychosocial and esthetic self-perception, after 1 year. Methods Patients (n = 25) were assessed at 12 months post bleaching treatment (whitening with 6% chemo-activated alkaline formula gel versus 37.5% traditional concentration gel). Color changes were measured objectively using total variation in color (ΔE), and subjectively using Vita Classical and Vita Bleached scale (ΔSGU) by calibrated evaluators (Kappa = 0.85). The Psychosocial Impact of Dental Aesthetics Questionnaire (PIDAQ) and Oral Health Impact Profile (OHIP-14) aesthetic questionnaires were used to measure the self-perception and the psychosocial impact of the bleaching protocols. Results The effect (ΔE) of 37.5% HP (8.37 ± 2.73) was significantly better than that of 6% HP (5.27 ± 2.53) in terms of color rebound after 1 year of follow-up. There were significant differences in psychosocial impact and esthetic self-perception measurements prior to bleaching versus one-year post-whitening time points; positive effects were maintained. Conclusions Low concentration (6%) achieved effective bleaching with good stability after 1 year, accompanied by a positive psychosocial impact and enhanced self-perception at follow-up. Trial registration NCT03217994 (before enrollment of the first participant). Data register: July 14, 2017.
Collapse
Affiliation(s)
- J Estay
- Department of Restorative Dentistry - Faculty of Dentistry, University of Chile, Sergio Livingstone Pohlhammer 943, Independencia, Santiago, Chile
| | - P Angel
- Department of Restorative Dentistry - Faculty of Dentistry, University of Chile, Sergio Livingstone Pohlhammer 943, Independencia, Santiago, Chile
| | - C Bersezio
- Department of Restorative Dentistry - Faculty of Dentistry, University of Chile, Sergio Livingstone Pohlhammer 943, Independencia, Santiago, Chile
| | - M Tonetto
- Postgraduate Program in Integrated Dental Sciences, University of Cuiabá, Cuiabá, Brazil
| | - G Jorquera
- Department of Prosthodontics, College of Dentistry, Universidad de Los Andes, Santiago, Chile
| | - M Peña
- Department of Restorative Dentistry - Faculty of Dentistry, University of Chile, Sergio Livingstone Pohlhammer 943, Independencia, Santiago, Chile
| | - E Fernández
- Department of Restorative Dentistry - Faculty of Dentistry, University of Chile, Sergio Livingstone Pohlhammer 943, Independencia, Santiago, Chile. .,Instituto de Ciencias Biomédicas - Universidad Autónoma de Chile, Av. Pedro de Valdivia 425, Providencia, Santiago, Chile.
| |
Collapse
|
17
|
Chen YH, Yang S, Hong DW, Attin T, Yu H. Short-term effects of stain-causing beverages on tooth bleaching: A randomized controlled clinical trial. J Dent 2020; 95:103318. [PMID: 32169479 DOI: 10.1016/j.jdent.2020.103318] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2020] [Revised: 03/05/2020] [Accepted: 03/09/2020] [Indexed: 11/25/2022] Open
Abstract
OBJECTIVES To evaluate the short-term effects of stain-causing beverages on the effectiveness of in-office tooth bleaching. METHODS Participants were recruited and randomly divided into 3 groups based on beverages used for rinsing during and after the bleaching procedure: group N (tap water, control group), group C (coffee), and group T (tea). Participants were instructed to rinse with the respective solutions for 30 s, 4 times daily for 4 weeks. All participants received two in-office bleaching treatment sessions with 40 % hydrogen peroxide (Opalescence BOOST PF 40 %, Ultradent); the sessions were separated by a 1-week interval. Tooth colour was assessed using a spectrophotometer (Easyshade, Vita ZahnFabrik) before the bleaching procedure (T0), immediately after the first session of bleaching (T1), immediately after the second session of bleaching (T2), as well as one week (T3) and three weeks after (T4) the end of bleaching. Tooth sensitivity (TS) was ranked using a numerical rating scale (NRS) and a visual analogue scale (VAS) at different time points. RESULTS No significant difference in the whiteness index (W), △E, △a* and △b* values among the 3 groups was observed at any time interval (P for all > 0.05). At T4, the △L* value in group C was significantly lower than that in groups T and N (P = 0.022 and P = 0.001, respectively), though no significant difference in △L* values was observed among the 3 groups at T1 (P = 0.402), T2 (P = 0.643) and T3 (P = 0.177). Additionally, no significant difference was found in the TS values among the 3 groups at any of the evaluation time points (P for all > 0.05). CONCLUSIONS Exposure to coffee or tea during the bleaching treatment period did not affect the effectiveness of the treatment. However, exposure to coffee after the bleaching treatment did affect the effectiveness of the treatment. Exposure to stain-causing beverages did not affect the bleaching-induced TS (ClinicalTrials.gov Identifier: NCT03933527). CLINICAL SIGNIFICANCE The consumption of coffee or tea during tooth bleaching may not interfere with the colour change produced by the treatment. However, clinicians should advise their patients to refrain from, at least to some extent, consuming coffee after the bleaching procedure to maintain the effectiveness of the treatment.
Collapse
Affiliation(s)
- Ying-Hui Chen
- Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key Laboratory of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University, China
| | - Song Yang
- Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key Laboratory of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University, China
| | - Deng-Wei Hong
- Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key Laboratory of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University, China
| | - Thomas Attin
- Clinic of Conservative and Preventive Dentistry, Center of Dental Medicine, University Zurich, Zurich, Switzerland
| | - Hao Yu
- Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key Laboratory of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University, China; Department of Applied Prosthodontics, Graduate School of Biomedical Sciences, Nagasaki University, Japan.
| |
Collapse
|
18
|
Abbasi M, Pordel E, Chiniforush N, Firuzjaee SG, Omrani LR. Hydrogen peroxide penetration into the pulp chamber during conventional in-office bleaching and diode laser-assisted bleaching with three different wavelengths. Laser Ther 2019; 28:285-290. [PMID: 32255920 PMCID: PMC7087340 DOI: 10.5978/islsm.19-or-20] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2019] [Accepted: 11/11/2019] [Indexed: 11/06/2022]
Abstract
BACKGROUND AND AIMS Penetration of hydrogen peroxide into the pulp chamber and subsequent tooth hypersensitivity is a common concern in dental bleaching. The aim of this study was to assess the penetration of hydrogen peroxide (H2O2) into the pulp chamber in diode-laser activated bleaching with different laser wavelengths. MATERIALS AND METHODS Fifty extracted human maxillary anterior teeth were collected and divided into five groups(n = 10). Group 1: conventional in-office bleaching using Opalescence Boost gel. Group 2: Bleaching with Biolase Laser White 20 gel activated by 980 nm diode laser. Group 3: Bleaching with Biolase Laser White 20 gel activated by 810 nm diode laser. Group 4: Bleaching with Biolase Laser White 20 gel activated by 940 nm diode laser. Group 5: No bleaching control group.After bleaching, the solution into the pulp chamber was collected and analyzed using a spectrophotometer. The recorded data were compared with a standard sample and the results were analyzed and compared using one-way ANOVA and Tukey's HSD tests. RESULTS In all bleached groups, H2O2 had infiltrated into the pulp chamber. The highest level of penetration was noted in group 2 (2.32 ± 0.25 µg), while the lowest level was noted in group 3 (1.85 ± 0.33 µg). The difference in this regard was significant between groups 2 and 3 (P = 0.024), but the differences between other groups were not statistically significant (P ≥ 0.42). CONCLUSION Considering the results of this study, it can be stated that hydroge peroxide penetration in to pulp chamber in diode laser activation of bleaching agent according to manufactures instruction is not higher than in-office bleaching. The wavelength of diode laser had significant effect on penetration of hydrogen peroxide into pulp chamber.
Collapse
Affiliation(s)
- Mahdi Abbasi
- DDS, MSc's, assistant professor, Restorative Dentistry Department, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
| | - Edris Pordel
- Department of Pediatric Dentistry, Borujerd Branch, Islamic Azad University Boroujerd, Iran
| | - Nasim Chiniforush
- Dentist, PhD of laser dentistry, Laser Research Canter of Dentistry, Dental Research Institute, Tehran University of Medical Sciences, Tehran, Iran
| | - Sattar Gorgani Firuzjaee
- DDS. Department of Medical Laboratory Sciences, School of Allied Health Medicine, Aja University of Medical Sciences, Tehran, Iran
| | - Ladan Ranjbar Omrani
- DDS, MSc's, associate professor, Restorative Dentistry Department, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
| |
Collapse
|
19
|
Kikly A, Jaâfoura S, Sahtout S. Vital laser‐activated teeth bleaching and postoperative sensitivity: A systematic review. J ESTHET RESTOR DENT 2019; 31:441-450. [DOI: 10.1111/jerd.12482] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2019] [Revised: 03/17/2019] [Accepted: 03/27/2019] [Indexed: 11/29/2022]
Affiliation(s)
- Amira Kikly
- Assistant professor, Department of Conservative OdontologyFaculty of Dental Medicine, University of Monastir Monastir Tunisia
- ABCDF LaboratoryFaculty of Dental Medicine, University of Monastir Monastir Tunisia
| | - Sabra Jaâfoura
- Assistant professor, Department of Dental BiomaterialsFaculty of Dental Medicine, University of Monastir Monastir Tunisia
- ABCDF LaboratoryFaculty of Dental Medicine, University of Monastir Monastir Tunisia
| | - Saida Sahtout
- Professor, Department of Conservative OdontologyFaculty of Dental Medicine, University of Monastir Monastir Tunisia
- ABCDF LaboratoryFaculty of Dental Medicine, University of Monastir Monastir Tunisia
| |
Collapse
|
20
|
Lilaj B, Dauti R, Agis H, Schmid-Schwap M, Franz A, Kanz F, Moritz A, Schedle A, Cvikl B. Comparison of Bleaching Products With Up to 6% and With More Than 6% Hydrogen Peroxide: Whitening Efficacy Using BI and WI D and Side Effects - An in vitro Study. Front Physiol 2019; 10:919. [PMID: 31543822 PMCID: PMC6728628 DOI: 10.3389/fphys.2019.00919] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2019] [Accepted: 07/05/2019] [Indexed: 12/30/2022] Open
Abstract
The aim of this study was to evaluate the effect of bleaching agents containing different concentrations of hydrogen peroxide (HP) on color-change and on enamel-surface in bovine teeth. Furthermore the influence on cell viability and proliferation was investigated. Two hundred and forty teeth were randomly assigned into four groups (home bleaching ≤6%, in-office bleaching ≤6%, in-office bleaching > 6% HP, and control group). Bleaching was performed after artificial staining and the bleached index (BI) as well as the whiteness index (WID) was measured at several time points. Chemical analysis for HP concentrations and the pH of the bleaching products was done. Furthermore, enamel surfaces of randomly selected specimens were analyzed using scanning electron microscopy (SEM) and cytotoxicity of the tested bleaching products was evaluated in vitro using dental pulp cells (DPCs) and L929 cells. A statistically significant whitening effect was observed in almost all products. As expected all investigated products resulted in decreased cell viability, however, with different values of LC50 (median lethal concentration). SEM analysis showed an analog of enamel alterations with decreasing pH, increasing exposure time, and increasing HP concentration. Bleaching agents containing a low HP concentration are considered to be effective and to have less damaging effects on enamel and tested cells.
Collapse
Affiliation(s)
- Bledar Lilaj
- Department of Conservative Dentistry and Periodontology, University Clinic of Dentistry, Medical University of Vienna, Vienna, Austria
| | - Rinet Dauti
- Department of Conservative Dentistry and Periodontology, University Clinic of Dentistry, Medical University of Vienna, Vienna, Austria
| | - Hermann Agis
- Department of Conservative Dentistry and Periodontology, University Clinic of Dentistry, Medical University of Vienna, Vienna, Austria
| | - Martina Schmid-Schwap
- Department of Prosthodontics, University Clinic of Dentistry, Medical University of Vienna, Vienna, Austria
| | - Alexander Franz
- Department of Conservative Dentistry and Periodontology, University Clinic of Dentistry, Medical University of Vienna, Vienna, Austria
| | - Fabian Kanz
- Center for Forensic Medicine, Medical University of Vienna, Vienna, Austria
| | - Andreas Moritz
- Department of Conservative Dentistry and Periodontology, University Clinic of Dentistry, Medical University of Vienna, Vienna, Austria
| | - Andreas Schedle
- Department of Conservative Dentistry and Periodontology, University Clinic of Dentistry, Medical University of Vienna, Vienna, Austria
| | - Barbara Cvikl
- Department of Conservative Dentistry and Periodontology, University Clinic of Dentistry, Medical University of Vienna, Vienna, Austria.,Department of Conservative Dentistry, Sigmund Freud University, Vienna, Austria
| |
Collapse
|
21
|
Bersezio C, Estay J, Jorquera G, Peña M, Araya C, Angel P, Fernández E. Effectiveness of Dental Bleaching With 37.5% and 6% Hydrogen Peroxide and Its Effect on Quality of Life. Oper Dent 2019; 44:146-155. [DOI: 10.2341/17-229-c] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
SUMMARY
Objective:
This study investigated whether it is possible to achieve equally satisfactory results between 37.5% hydrogen peroxide (HP) gel and 6% HP gel. We also assessed the psychosocial impact and self-perception of esthetics generated by extracoronal tooth whitening.
Methods and Materials:
A prospective, double-blind, randomized clinical trial was carried out. A total of 33 patients were selected from the clinic of the Faculty of Dentistry at the University of Chile. The patients included men and women over 18 years old without prior tooth whitening treatments, tooth decay, or restorations of the maxillary anterior teeth. The patients had tooth colors of A3 or less according to the Vita Classical scale, which was determined with a Vita Easy Shade spectrophotometer. The study was carried out with a “split-mouth” design. One side of each mouth was randomly treated with 37.5% HP, and the other side was bleached with 6% HP. Each group received 3 to 12 minutes of treatment with the respective gel applications. Two sessions of bleaching were carried out each week. A spectrophotometer was used to measure the total variation of color (ΔE), and a subjective evaluation was made with Vita Classical scale (ΔSGU) between the baseline (session 1) and different measurement times. We compared ΔE and ΔSGU for both agents using the Mann-Whitney test (α=0.05).
Results:
In both groups, there was variation among the initial color and the color in the different measurement times. In the month after the treatment was completed, ΔE was 9.06 in the 37.5% HP group and 5.69 in the 6% HP group. The difference between the two groups was statistically significant starting in the second session (p=0.000).
Conclusion:
There was a significant difference between the effectiveness of the bleaching gel concentrations of 37.5% and 6% HP according to spectrophotometer measurements and subjective evaluations. There was also a positive effect on psychosocial impact and esthetic self-perception among patients.
Collapse
Affiliation(s)
- C Bersezio
- Cristian Bersezio, Department of Restorative Dentistry, Operative Dentistry, University of Chile, Santiago, Chile and Universidad Andres Bello, Santiago, Chile
| | - J Estay
- Juan Estay, Department of Restorative Dentistry, Operative Dentistry, University of Chile, Santiago, Chile
| | - G Jorquera
- Gilbert Jorquera, Department of Prosthodontics, College of Dentistry, Universidad de Los Andes, Santiago, Chile
| | - M Peña
- Manuel Peña, Departament of Restorative Dentistry, University of Chile Dental School, Santiago, Chile
| | - C Araya
- Carolina Araya, Departament of Restorative Dentistry, University of Chile Dental School, Santiago, Chile Pablo Angel, Departament of Restorative Dentistry, University of Chile Dental School, Santiago, Chile
| | - P Angel
- Carolina Araya, Departament of Restorative Dentistry, University of Chile Dental School, Santiago, Chile Pablo Angel, Departament of Restorative Dentistry, University of Chile Dental School, Santiago, Chile
| | | |
Collapse
|
22
|
Hortkoff D, Bittencourt BF, Nadal JM, Gomes OM, Rezende M, de Almeida Farhat PB. Clinical Study of Bleaching Gel Storage Temperature on Tooth Color and Sensitivity. Oper Dent 2019; 44:459-468. [PMID: 30702403 DOI: 10.2341/17-302-c] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
OBJECTIVE The objective of this triple-blind, split-mouth, randomized clinical trial was to evaluate the bleaching efficacy and tooth sensitivity of an in-office bleaching agent submitted to different storage temperatures (room temperature at 21.04°C±3.13°C or refrigeration at 5°C). METHODS AND MATERIALS Thirty volunteers were selected who had central incisors with color A2 or higher. The volunteers' maxillary hemi-arches received either the bleaching treatment with room temperature or refrigerated storage temperatures (two sessions of 3×15 minutes, one-week interval). Color variation was evaluated by subjective (Vita Classic and Vita Bleachedguide) and objective methods (Vita Easyshade spectrophotometer). Tooth sensitivity was evaluated with the visual analog scale (0-10) and the numerical rating scale (five points). The consistency of bleaching gels was evaluated by flow test, and pH was measured, both in triplicate. Color variation (SGU) and ΔE were analyzed by paired t-test (α=0.05). The absolute risk of pain was assessed by McNemar test (α=0.05), data from the numerical rating scale by the Wilcoxon signed-rank test (α=0.05), and visual analog scale by paired t-test. Comparison between the times within each group was analyzed by Friedman test. Gel consistency and pH were analyzed by one-way analysis of variance and Tukey post-test. RESULTS Regarding the absolute risk of tooth sensitivity, no significant difference was observed between the groups. The relative risk for tooth sensitivity was 1.13 (95%, confidence interval 0.70-1.82). Both tooth sensitivity scales were statistically similar. The results of the subjective evaluation (Vita Classic: p=0.73, Vita Bleachedguide: p=1.00) and the objective evaluation (p=1.00) of bleaching efficacy corresponded to the hypothesis of equality between groups after bleaching. Both pH values were around 7, and for the consistency test, there were significant differences between the groups (p=0.002). CONCLUSIONS Storage temperature of the analyzed in-office bleaching agent had no influence on tooth color effectiveness and tooth sensitivity.
Collapse
|
23
|
Jiang N, Zhang C, Agingu C, Attin T, Cheng H, Yu H. Comparison of Whitening Dentifrices on the Effectiveness of In-office Tooth Bleaching: A Double-blind Randomized Controlled Clinical Trial. Oper Dent 2018; 44:138-145. [PMID: 30106335 DOI: 10.2341/17-333-c] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
OBJECTIVES: To investigate the effect of whitening dentifrices on the effectiveness of in-office tooth bleaching. METHODS AND MATERIALS: A double-blind randomized controlled clinical trial was performed. The participants were randomly allocated into three groups according to the different dentifrices used during this clinical trial: regular dentifrice (group C), conventional whitening dentifrice (group CW), and whitening dentifrice containing blue covarine (group CU). All participants received in-office tooth bleaching for the maxillary anterior teeth (two sessions conducted at a one-week interval). Tooth color was measured with a spectrophotometer at baseline (T1), after the first bleaching session (T2), after the second bleaching session (T3); one week after the completion of in-office bleaching (T4); and three weeks after the completion of in-office bleaching (T5). The data were statistically analyzed through repeated analysis of variance and the Tukey test (α=0.05). RESULTS: Sixty participants completed the study (n=20 per group). At T3, group CU exhibited the lowest ΔE values ( p=0.008). The ΔE values increased from T4 to T5 in the CW and CU groups, whereas a decrease in ΔE values was observed for group C. CONCLUSIONS: The use of a whitening dentifrice containing blue covarine during in-office bleaching reduced color changes. After tooth bleaching, brighter tooth colors were observed in the participants who brushed with whitening dentifrices compared to those who brushed with a regular dentifrice.
Collapse
|
24
|
Bersezio C, Ledezma P, Estay J, Mayer C, Rivera O, Fernández E. Color Regression and Maintenance Effect of Intracoronal Whitening on the Quality of Life: RCT-A One-year Follow-up Study. Oper Dent 2018; 44:24-33. [PMID: 30059269 DOI: 10.2341/17-288-c] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
OBJECTIVE: This randomized clinical study evaluated two parameters: 1) the clinical color rebound of whitening patients' tooth discoloration using the walking bleaching technique and 2) the impact on psychological and aesthetic self-perception at the one-year follow-up of patients who underwent bleaching of nonvital teeth. METHODS AND MATERIALS: Fifty study participants with nonvital tooth discoloration were recruited. Teeth were assigned randomly into one of two groups: 1) 35% hydrogen peroxide (n=25) and 2) 37% carbamide peroxide (n=25). Intracoronal bleaching was carried out over the course of four sessions using the walking bleach technique. Tooth color was evaluated after each session in order to measure the total color variation (ΔE). The guide was arranged from highest (B1) to lowest values (C4) for evaluating color, and color changes using Vita Classical Shade (ΔSGUs) units were calculated. Subjective and objective assessments were compared with the counterpart of the tooth. Aesthetic perception and psychosocial factors were evaluated before and after treatment by the Oral Health Impact Profile (OHIP) and Psychological Impact of Dental Impact Questionnaire (PIDAQ) surveys. RESULTS: Color changes (ΔE) were 15.48 ± 5.17 and 14.02 ± 4.85 for carbamide and hydrogen peroxide groups, respectively. There were no significant differences ( p>0.05) between these two groups at the one-year follow-up. There was a decrease in the PIDAQ scores after treatment compared to baseline values ( p<0.05). The majority of OHIP values regressed to baseline values. CONCLUSION: The technique of walking bleaching was highly effective and showed minimal color rebound in nonvital teeth and had a positive effect on patients' psychological impact at the one-year follow-up.
Collapse
|
25
|
Bersezio C, Martín J, Angel P, Bottner J, Godoy I, Avalos F, Fernández E. Teeth whitening with 6% hydrogen peroxide and its impact on quality of life: 2 years of follow-up. Odontology 2018; 107:118-125. [DOI: 10.1007/s10266-018-0372-3] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2017] [Accepted: 06/19/2018] [Indexed: 12/21/2022]
|
26
|
Vildósola P, Bottner J, Avalos F, Godoy I, Martín J, Fernández E. Teeth bleaching with low concentrations of hydrogen peroxide (6%) and catalyzed by LED blue (450 ± 10 nm) and laser infrared (808 ± 10 nm) light for in-office treatment: Randomized clinical trial 1-year follow-up. J ESTHET RESTOR DENT 2017; 29:339-345. [PMID: 28712152 DOI: 10.1111/jerd.12318] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
OBJECTIVES The aim of this study was to evaluate color longevity after a year of in-office bleaching with gel (6% hydrogen peroxide HP, LED blue/laser infrared activation system) compared to a 35% control concentration in a split-mouth study model. MATERIALS AND METHODS Thirty-one patients were initially treated. The bleaching procedure with 6% or 35% gel HP was performed randomly in the upper half arcade of each patient. The color was measured at baseline and at 1 week, 1 month, and 1 year using the spectrophotometer Vita Easyshade, Vita Bleached, and Vita classical Shade guide organized by value. During the 1-year recall, the color was assessed before and after dental prophylaxis. RESULTS Only 27 patients were assessed in the 1-year recall. There was a significant difference in the ΔE between the two groups at all times assessed (P < .011). The ΔL, Δa, and Δb showed significant difference between both groups at all assessed times (P < .038). There was no significant difference between the ΔSGU at all times (P > .05) except for the Vita bleachedguide postprophylaxis comparison (P < .05). CONCLUSION The two compounds remained effective at 1 year. When objectively evaluated, color difference between groups was found, not seen when subjectively determined. CLINICAL SIGNIFICANCE A low concentration hydrogen peroxide bleaching agent can reach good clinical results at 1 year of follow-up.
Collapse
Affiliation(s)
- Patricio Vildósola
- Department of Restorative Dentistry, Faculty of Dentistry, University of Chile, Santiago, Chile.,Universidad Andres Bello
| | - Jessica Bottner
- Department of Restorative Dentistry, Faculty of Dentistry, University of Chile, Santiago, Chile
| | - Francisca Avalos
- Department of Restorative Dentistry, Faculty of Dentistry, University of Chile, Santiago, Chile
| | - Isidora Godoy
- Department of Restorative Dentistry, Faculty of Dentistry, University of Chile, Santiago, Chile
| | - Javier Martín
- Department of Restorative Dentistry, Faculty of Dentistry, University of Chile, Santiago, Chile
| | - Eduardo Fernández
- Department of Restorative Dentistry, Faculty of Dentistry, University of Chile, Santiago, Chile.,Instituto de Ciencias Biomédicas, Universidad Autónoma de Chile, Chile
| |
Collapse
|