1
|
Jamshidi S, Alaghemand H, Esmaeili B, Gholinia H. Effects of Different Concentrations of Carbamide Peroxide on Color, Surface Roughness, and Hardness of CAD/CAM Dental Ceramics. Clin Exp Dent Res 2024; 10:e916. [PMID: 38970227 PMCID: PMC11226538 DOI: 10.1002/cre2.916] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2023] [Revised: 05/10/2024] [Accepted: 05/21/2024] [Indexed: 07/08/2024] Open
Abstract
OBJECTIVES This study assessed the effects of 15% and 20% carbamide peroxide (CP) on color, surface roughness, and hardness of computer-aided design/computer-aided manufacturing (CAD/CAM) dental ceramics. MATERIALS AND METHODS This in vitro study was conducted on 120 Vita Mark II, Celtra Duo, and Suprinity CAD/CAM ceramic specimens. The ceramic specimens in each group (n = 40) were randomly assigned to two subgroups (n = 20) for polishing and glazing, and their baseline color, surface roughness (Ra), and hardness were assessed. In each subgroup, half of the specimens were exposed to 15% CP, while the other half were exposed to 20% CP. Their color change (ΔE), surface roughness, and hardness were then measured again. Surface roughness, hardness, and color were analyzed sequentially by profilometer, Vickers hardness tester, and spectrophotometer, respectively. Data were analyzed by repeated measures ANOVA, one-way ANOVA, and post hoc Bonferroni test (α = 0.05). RESULTS The surface roughness of all groups significantly increased after bleaching treatment (p < 0.05). Surface hardness of all groups decreased after bleaching treatment, but this reduction was only significant in Vita Mark II subgroups (glazed, polished, 15%, and 20% CP). The ΔE was not clinically and visually perceivable in any group. CONCLUSION The present results revealed that concentration of CP and type of surface treatment affected the surface properties of CAD/CAM ceramics. Type of surface treatment only affected the surface hardness of Vita Mark II ceramics (p < 0.05). Concentration of CP had a significant effect only on polished Vita Mark II.
Collapse
Affiliation(s)
- Saman Jamshidi
- Department of Restorative Dentistry, School of DentistryBabol University of Medical SciencesBabolIran
| | - Homayoun Alaghemand
- Department of Restorative Dentistry, Dental Materials Research Center, School of Dentistry, Health Research InstituteBabol University of Medical SciencesBabolIran
| | - Behnaz Esmaeili
- Health Research Department, Oral Health Research Center, Health Research InstituteBabol University of Medical SciencesBabolIran
| | - Hemmat Gholinia
- Health Research Department, School of Dentistry, Health Research InstituteBabol University of Medical SciencesBabolIran
| |
Collapse
|
2
|
Laborie M, Naveau A, Menard A. CAD-CAM resin-ceramic material wear: A systematic review. J Prosthet Dent 2024; 131:812-818. [PMID: 35459543 DOI: 10.1016/j.prosdent.2022.01.027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2021] [Revised: 01/24/2022] [Accepted: 01/24/2022] [Indexed: 10/18/2022]
Abstract
STATEMENT OF PROBLEM The increasing use of computer-aided design and computer-aided manufacturing (CAD-CAM) systems has led to the development of resin-ceramic materials that meet the requirements of minimally invasive dentistry, including the resin nanoceramic (RNC) and polymer-infiltrated ceramic network (PICN). The wear characteristics of these materials are unclear. PURPOSE The purpose of this systematic review was to compare the wear resistance of resin-ceramic materials when compared with one another or with lithium disilicate glass-ceramics. MATERIAL AND METHODS The PubMed, Scopus, and DOSS search engines were used to identify articles published between 2013 and 2021. Two independent researchers conducted the systematic review by following the preferred reporting items for systematic reviews and meta-analyses (PRISMA) guidelines and by following a combination of keywords. RESULTS Of a total of 310 articles, 26 were selected, including only 1 clinical study. Among these, 15 compared resin-ceramic materials with each other, while 11 compared resin-ceramic materials with lithium disilicate ceramics. Two types of wear were used to compare the materials: attrition and abrasion. The most commonly studied materials were 2 RNCs (Lava Ultimate and Cerasmart), 1 PICN (Vita Enamic), and 1 ceramic (IPS e.max CAD). Among the resin-ceramic materials, the PICN (Vita Enamic) showed less wear than the RNCs. Of the RNCs, Cerasmart had less attrition wear and less wear of the opposing teeth. CONCLUSIONS Lithium disilicate glass-ceramics have a higher wear resistance than resin-ceramic materials, but they cause more wear of the opposing teeth.
Collapse
Affiliation(s)
| | - Adrien Naveau
- Associate Professor, Prosthodontics Department, Dental Faculty, University of Bordeaux, Bordeaux, France; Head of Unit, Periodontology and Prosthodontics Unit, Saint Andre Hospital, Bordeaux University Hospital, Bordeaux, France
| | - Aude Menard
- Assistant Professor, Prosthodontics Department, Dental Faculty, University of Bordeaux, Bordeaux, France; Assistant Professor, Periodontology and Prosthodontics Unit, Xavier Arnozan Hospital, Bordeaux University Hospital, Bordeaux, France
| |
Collapse
|
3
|
Mao Z, Beuer F, Hey J, Schmidt F, Sorensen JA, Prause E. Antagonist enamel tooth wear produced by different dental ceramic systems: A systematic review and network meta-analysis of controlled clinical trials. J Dent 2024; 142:104832. [PMID: 38211687 DOI: 10.1016/j.jdent.2024.104832] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2023] [Revised: 12/14/2023] [Accepted: 01/04/2024] [Indexed: 01/13/2024] Open
Abstract
OBJECTIVES The aim of this study was to evaluate the amount of enamel tooth wear induced by different antagonistic ceramic crown materials in the posterior area within a follow-up period up to 24 months in function. A network meta-analysis was performed to assess the effect of the materials on the mean vertical loss (MVL) of the antagonist enamel tooth surface. DATA Main search terms used in combination: ceramic, dental materials, metal ceramic, tooth wear and dental enamel. SOURCES An electronic search was conducted in PubMed/Medline, Embase, and Cochrane CENTRAL plus hand-searching. STUDY SELECTION Eligibility criteria included clinical studies reporting on MVL on antagonist's tooth up to 24 months following the permanent crown placement. From a total of 5697 articles, 7 studies reporting on 261 crowns for 177 subjects with 3 ceramic materials (Lithium disilicate, metal-ceramic, monolithic zirconia) were included. Among all, metal-ceramic and zirconia caused significantly higher enamel tooth wear on antagonist teeth, representing 82.5 µm [54.4; 110.6]) and 40.1 µm [22.2; 58.0]) more MVL than natural teeth group. In contrast, lithium disilicate showed only 5.0 µm [-48.2; 58.1]) more MVL than occurs on opposing natural teeth. CONCLUSIONS This systematic review demonstrated that prosthodontic ceramic materials produced significantly more antagonist enamel tooth wear than opposing natural enamel tooth wear, and ceramic material type was correlated to the degree of enamel tooth wear. Additional well-conducted, randomized controlled trials with homogeneous specimens are required due to inadequate sample size and number of the clinical studies included in the analyses. CLINICAL SIGNIFICANCE The amount of wear caused by different restorative materials has a high influence on the antagonistic natural teeth and should therefore be evaluated intensively by the dentist.
Collapse
Affiliation(s)
- Zhen Mao
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Aßmannshauser Str. 4-6 14197, Berlin, Germany.
| | - Florian Beuer
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Aßmannshauser Str. 4-6 14197, Berlin, Germany
| | - Jeremias Hey
- Department of Prosthodontics, School of Dental Medicine, Martin-Luther-University, Halle, Germany
| | - Franziska Schmidt
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Aßmannshauser Str. 4-6 14197, Berlin, Germany
| | - John A Sorensen
- Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, USA
| | - Elisabeth Prause
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Aßmannshauser Str. 4-6 14197, Berlin, Germany
| |
Collapse
|
4
|
Nascimento VA, Bento VAA, Cruz KH, Silva LS, Pesqueira AA, Pellizzer EP. Color stability and surface roughness of resin-ceramics with different surface treatments: A systematic review and meta-analysis of in vitro studies. J Prosthet Dent 2023:S0022-3913(23)00567-X. [PMID: 37805289 DOI: 10.1016/j.prosdent.2023.08.023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Revised: 08/22/2023] [Accepted: 08/23/2023] [Indexed: 10/09/2023]
Abstract
STATEMENT OF PROBLEM Surface treatments for resin-ceramics have been developed to obtain a smooth surface and improve color stability. However, a consensus on the best treatment for these materials is lacking. PURPOSE The purpose of this systematic review and meta-analysis was to evaluate the color stability and roughness of glass-ceramics versus resin-ceramics with different surface treatments. MATERIAL AND METHODS The preferred reporting items for systematic reviews and meta-analyses (PRISMA) guidelines were followed, and the study was registered in the open science framework (OSF) for in vitro studies. The population, intervention, control, and outcome (PICO) question was "Is there a difference in color stability and roughness between resin-ceramic vs vitreous ceramics in different surface treatment protocols?" A literature search was performed in PubMed/MEDLINE, Embase, Web of Science, Scopus, Cochrane Library, and ProQuest databases up to January 2023. The Joanna Briggs Institute's critical assessment guidelines for quasi-experimental studies were used for quality assessment. The meta-analysis was based on the inverse variance (IV) method (α=.05). RESULTS A total of 18 laboratory studies were published between 2015 and 2022, with a total of 2160 specimens, all of which were analyzed qualitatively. The meta-analysis indicated significantly less optical alteration for lithium disilicate ceramics (P<.01; MD: 2.69; 95% CI: 2.00-3.39; I²=89%, P<.01), even when compared with resin-ceramics with polish or sealants (P<.01; MD: 2.45; 95% CI: 1.59-3.30; I²=87%, P<.01) and (P<.01; MD: 3.24; 95% CI: 2.02-4.47; I²=89%, P<.01), while there was no significant difference in surface roughness (P=.08; MD: -0.71; CI 95%: -1.52 to 0.09; I²=87%, P<.01) (P=.33; MD: -0.31; CI 95%: -0.94 to 0.32; I²=87%, P<.01), respectively. CONCLUSIONS Resin-ceramics that have been polished or treated with sealants have lower color stability than glazed glass-ceramics; however, they are similar in terms of surface roughness.
Collapse
Affiliation(s)
- Victor Alves Nascimento
- Postgraduate student, Department of Dental Materials and Prosthodontics, Araçatuba Dental School, São Paulo State University (UNESP), Araçatuba, São Paulo, Brazil.
| | - Victor Augusto Alves Bento
- Postgraduate student, Department of Dental Materials and Prosthodontics, Araçatuba Dental School, São Paulo State University (UNESP), Araçatuba, São Paulo, Brazil
| | - Kevin Henrique Cruz
- Postgraduate student, Department of Dental Materials and Prosthodontics, Araçatuba Dental School, São Paulo State University (UNESP), Araçatuba, São Paulo, Brazil
| | - Lorena Scaion Silva
- Postgraduate student, Department of Dental Materials and Prosthodontics, Araçatuba Dental School, São Paulo State University (UNESP), Araçatuba, São Paulo, Brazil
| | - Aldiéris Alves Pesqueira
- Adjunct Professor, Department of Dental Materials and Prosthodontics, Araçatuba Dental School, São Paulo State University (UNESP), Araçatuba, São Paulo, Brazil
| | - Eduardo Piza Pellizzer
- Full Professor, Department of Dental Materials and Prosthodontics, Araçatuba Dental School, São Paulo State University (UNESP), Araçatuba, São Paulo, Brazil
| |
Collapse
|
5
|
Çakmak G, Subaşı MG, Sert M, Yilmaz B. Effect of surface treatments on wear and surface properties of different CAD-CAM materials and their enamel antagonists. J Prosthet Dent 2023; 129:495-506. [PMID: 34301415 DOI: 10.1016/j.prosdent.2021.06.023] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2020] [Revised: 06/15/2021] [Accepted: 06/15/2021] [Indexed: 10/20/2022]
Abstract
STATEMENT OF PROBLEM Which surface treatment provides optimal surface roughness, microhardness, and wear behavior for computer-aided design and computer-aided manufacturing (CAD-CAM) materials and their enamel antagonists is unclear. PURPOSE The purpose of this in vitro study was to evaluate the effect of surface treatment on the surface roughness, microhardness, and 2-body wear of different CAD-CAM materials and their enamel antagonists. MATERIAL AND METHODS Monolithic zirconia, polymer-infiltrated ceramic network, lithium disilicate, leucite-reinforced ceramic, zirconia-reinforced lithium silicate, and feldspathic ceramic specimens were sliced into 2-mm-thick rectangular plates and divided into polished or glazed subgroups (n=6). After surface roughness and microhardness measurements, the specimens were loaded at 49 N for 250 000 cycles and simultaneously thermocycled (5 °C and 55 °C). All specimens were scanned before and after the wear test by using a scanner. The volumetric loss and wear depth of the materials and the volumetric and height loss of the enamel were calculated, and scanning electron microscope images of the specimens were made. Multiple 2-way ANOVAs and Tukey honestly significant difference tests were used to assess the effect of material and surface treatment on surface roughness, microhardness, and wear behavior of materials and enamel (α=.05). RESULTS Material and surface treatment interactions affected the surface roughness (P<.001), microhardness (P<.001), volumetric loss of materials (P=.044), and height loss of enamel (P<.001). CONCLUSIONS Polishing resulted in higher surface roughness and microhardness than glazing. Volumetric loss depended on the material, which affected the height loss of the antagonists. Glazing and polishing had similar effects on the volumetric loss of materials and antagonists. No correlation was found between the wear of materials and the antagonists, nor between the surface roughness of materials and the volumetric loss of materials or antagonists.
Collapse
Affiliation(s)
- Gülce Çakmak
- Buser Foundation Scholar for Implant Dentistry, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.
| | - Meryem Gülce Subaşı
- Associate Professor, Department of Prosthodontics, Faculty of Dentistry, Kütahya Sağlık Bilimleri University, Kütahya, Turkey
| | - Murat Sert
- Assistant Professor, Department of Medical Laboratory Techniques, Ankara Yildirim Beyazit University, Ankara, Turkey
| | - Burak Yilmaz
- Associate Professor, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Associate Professor, Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland; Adjunct Professor, Division of Restorative and Prosthetic Dentistry, The Ohio State University, Columbus, Ohio
| |
Collapse
|
6
|
Murbay S, Yeung SKW, Yip CY, Pow EHN. Assessing Enamel Wear of Monolithic Ceramics With Micro-CT and Intra-oral Scanner. Int Dent J 2022:S0020-6539(22)00255-6. [DOI: 10.1016/j.identj.2022.10.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2022] [Revised: 10/19/2022] [Accepted: 10/30/2022] [Indexed: 11/24/2022] Open
|
7
|
Jurado CA, Tsujimoto A, Watanabe H, Fischer NG, Hasslen JA, Tomeh H, Baruth AG, Barkmeier WW, Garcia-Godoy F. Evaluation of Polishing Systems for CAD/CAM Polymer-Infiltrated Ceramic-Network Restorations. Oper Dent 2021; 46:219-225. [PMID: 34192321 DOI: 10.2341/20-006-l] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/22/2020] [Indexed: 11/23/2022]
Abstract
OBJECTIVE The purpose of this study was to evaluate the effectiveness of five different polishing systems on a computer-aided design and computer-aided manufacturing (CAD/CAM) polymer-infiltrated ceramic-network restoration with nanoscale assessment using atomic force microscopy (AFM) and visual assessment performed by dental school senior students and faculty members. METHOD Forty-eight full coverage crowns were milled out of polymer-infiltrated ceramic-network CAD/CAM blocks (Vita Enamic) for polishing with one company proprietary, two ceramic and two composite polishing systems. The prepared crowns were divided into six groups: (1) no polishing (control); (2) polishing with Vita Enamic Polishing Kit (VEna); (3) polishing with Shofu Porcelain Laminate Polishing Kit (SCer); (4) polishing with Brasseler Dialite Feather lite All- Ceramic Adjusting & Polishing System (BCer); (5) polishing with Shofu Composite Polishing Kit (SCom); and (6) polishing with Brasseler Composite Polishing Kit (BCom). The polished crown surface topography was observed, and surface roughness and area were measured with AFM. In addition, polished crowns were visually assessed by 15 senior dental students and 15 dental school faculty members. RESULTS All polishing treatments significantly reduced the surface roughness and area of the crown compared with the control. SCom and BCom showed significantly higher surface area than VEna, and the SCer and BCer groups were intermediate, showing no significant difference from either VEna or SCom and BCom. There were no significant differences in surface roughness between any of the systems. Dental students and faculty members classified the groups polished with VEna, SCer, and BCer groups as clinically acceptable, and they selected BCer group as the best polished restorations and the control group as the least polished restorations. CONCLUSIONS Ceramic and composite polishing systems produced similar polishing results as that observed using a company proprietary polishing system. However, effectiveness for polishing using a company proprietary and ceramic polishing system tends to be higher than composite polishing systems.
Collapse
|
8
|
Aladağ A, Oğuz D, Çömlekoğlu ME, Akan E. In vivo wear determination of novel CAD/CAM ceramic crowns by using 3D alignment. J Adv Prosthodont 2019; 11:120-127. [PMID: 31080573 PMCID: PMC6491363 DOI: 10.4047/jap.2019.11.2.120] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2018] [Revised: 03/22/2019] [Accepted: 04/17/2019] [Indexed: 11/17/2022] Open
Abstract
PURPOSE To determine wear amount of single molar crowns, made from four different restoratives, and opposing natural teeth through computerized fabrication techniques using 3D image alignment. MATERIALS AND METHODS A total of 24 single crowns (N = 24 patients, age range: 18 – 50) were made from lithium disilicate (IPS E-max CAD), lithium silicate and zirconia based (Vita Suprinity CAD), resin matrix ceramic material (Cerasmart, GC), and dual matrix (Vita Enamic CAD) blocks. After digital impressions (Cerec 3D Bluecam, DentsplySirona), the crowns were designed and manufactured (Cerec 3, DentsplySirona). A dual-curing resin cement was used for cementation (Variolink Esthetic DC, Ivoclar). Then, measurement and recording of crowns and the opposing enamel surfaces with the intraoral scanner were made as well as at the third and sixth month follow-ups. All measurements were superimposed with a software (David-Laserscanner, V3.10.4). Volume loss due to wear was calculated from baseline to follow-up periods with Siemens Unigraphics NX 10 software. Statistical analysis was accomplished by Repeated Measures for ANOVA (SPSS 21) at = .05 significance level. RESULTS After 6 months, insignificant differences of the glass matrix and resin matrix materials for restoration/enamel wear were observed (P>.05). While there were no significant differences between the glass matrix groups (P>.05), significant differences between the resin matrix group materials (P<.05) were obtained. Although Cerasmart and Enamic were both resin matrix based, they exhibited different wear characteristics. CONCLUSION Glass matrix materials showed less wear both on their own and opposing enamel surfaces than resin matrix ceramic materials.
Collapse
Affiliation(s)
- Akın Aladağ
- Department of Prosthodontics, Faculty of Dentistry, Ege University, Izmir, Turkey
| | - Didem Oğuz
- Department of Prosthodontics, Faculty of Dentistry, Ege University, Izmir, Turkey
| | | | - Ender Akan
- Department of Prosthodontics, Faculty of Dentistry, İzmir Katip Çelebi University, Izmir, Turkey
| |
Collapse
|
9
|
Esmaeili B, Soleimani L, Alaghemand H, Fatemi S. Effect of heat treatment and addition of 4-META to silane on microtensile bond strength of IPS e.max CAD ceramic to resin cement. Dent Res J (Isfahan) 2019. [DOI: 10.4103/1735-3327.266086] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
|