1
|
Chen PH, Elamin E, Sayed Ahmed A, Givan DA, Fu CC, Lawson NC. The Effect of Restoration Thickness on the Fracture Resistance of 5 mol% Yttria-Containing Zirconia Crowns. MATERIALS (BASEL, SWITZERLAND) 2024; 17:365. [PMID: 38255531 PMCID: PMC10817558 DOI: 10.3390/ma17020365] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/18/2023] [Revised: 01/04/2024] [Accepted: 01/08/2024] [Indexed: 01/24/2024]
Abstract
BACKGROUND To determine what thickness of 5 mol% yttria zirconia (5Y-Z) translucent crowns cemented with different cements and surface treatments would have equivalent fracture resistance as 3 mol% yttria (3Y-Z) crowns. METHODS The study included 0.8 mm, 1.0 mm, and 1.2 mm thickness 5Y-Z (Katana UTML) crowns and 0.5 and 1.0 mm thickness 3Y-Z (Katana HT) crowns as controls. The 5Y-Z crowns were divided among three treatment subgroups (n = 10/subgroup): (1) cemented using RMGIC (Rely X Luting Cement), (2) alumina particle-abraded then luted with the same cement, (3) alumina particle-abraded and cemented using a resin cement (Panavia SA Cement Universal). The 3Y-Z controls were alumina particle-abraded then cemented with RMGIC. The specimens were then loaded in compression at 30° until failure. RESULTS All 5Y-Z crowns (regardless of thickness or surface treatment) had a similar to or higher fracture force than the 0.5 mm 3Y-Z crowns. Only the 1.2 mm 5Y-Z crowns with resin cement showed significantly similar fracture force to the 1 mm 3Y-Z crowns. CONCLUSION In order to achieve a similar fracture resistance to 0.5 mm 3Y-Z crowns cemented with RMGIC, 5Y-Z crowns may be as thin as 0.8 mm. To achieve a similar fracture resistance to 1.0 mm 3Y-Z crowns cemented with RMGIC, 5Y-Z crowns must be 1.2 mm and bonded with resin cement.
Collapse
Affiliation(s)
- Po-Hsu Chen
- Division of Prosthodontics, University of Alabama at Birmingham School of Dentistry, Birmingham, AL 35209, USA; (P.-H.C.); (E.E.); (D.A.G.); (C.-C.F.)
| | - Esra Elamin
- Division of Prosthodontics, University of Alabama at Birmingham School of Dentistry, Birmingham, AL 35209, USA; (P.-H.C.); (E.E.); (D.A.G.); (C.-C.F.)
| | - Akram Sayed Ahmed
- Faculty of Dentistry, Department of Dental Biomaterials, Tanta University, Tanta 31527, Egypt;
| | - Daniel A. Givan
- Division of Prosthodontics, University of Alabama at Birmingham School of Dentistry, Birmingham, AL 35209, USA; (P.-H.C.); (E.E.); (D.A.G.); (C.-C.F.)
| | - Chin-Chuan Fu
- Division of Prosthodontics, University of Alabama at Birmingham School of Dentistry, Birmingham, AL 35209, USA; (P.-H.C.); (E.E.); (D.A.G.); (C.-C.F.)
| | - Nathaniel C. Lawson
- Division of Prosthodontics, University of Alabama at Birmingham School of Dentistry, Birmingham, AL 35209, USA; (P.-H.C.); (E.E.); (D.A.G.); (C.-C.F.)
| |
Collapse
|
2
|
Tomm AGF, Machado PS, Rosa LSD, Pereira GKR, Spazzin AO, Alessandretti R. Fatigue resistance of monolithic and multilayer zirconia crowns using veneer layering or CAD-on technique. Braz Dent J 2023; 34:150-159. [PMID: 38133089 PMCID: PMC10742353 DOI: 10.1590/0103-6440202305687] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2023] [Accepted: 11/24/2023] [Indexed: 12/23/2023] Open
Abstract
This study aims to evaluate the fatigue resistance of monolithic zirconia (Yz) and multilayer ceramic structures using the CAD-on technique in different thicknesses. Fifty (N=50) standardized single crowns preparations were made in fiberglass-reinforced epoxy resin (NEMA grade G10), digitalized, and restorations were machined in CAD-CAM, composing 5 groups (n= 10): Control: 1.5 mm (milled zirconia framework + manual layered porcelain); Yz monolithic 1.5 mm; Yz monolithic 1.0 mm; CAD-on 1.5 mm; and CAD-on 1.0 mm (milled zirconia framework 0.5 mm thickness bonded by a low fuse ceramic to a milled lithium disilicate layer of 1.0 mm or 0.5 mm, respectively). The G10 bases were conditioned with 10% hydrofluoric acid; the crowns were air abraded with 110 μm alumina particles; and then luted onto each other with self-adhesive resin cement. A cyclic fatigue test was performed (initial load: 400N for 10,000 cycles, frequency of 20 Hz, step size of 200N) until failure, and the data was submitted to a survival statistical analysis. No failures were observed at Yz monolithic 1.5 mm. High and similar performance was observed for Cad-On groups and Yz monolithic 1.0 mm. The control group depicted the worst behavior. The Weibull modulus of CAD-on 1.5 mm was higher than the control while being similar to the other conditions. Both the monolithic systems and the CAD-on technique showed high and similar fatigue fracture behavior and survival rates, which were also higher than the control bilayer system. Both systems reduced the occurrence of delamination failures, making them suitable for clinical use.
Collapse
Affiliation(s)
| | - Pablo Soares Machado
- Post-Graduate Program in Oral Sciences, Center for Development of Advanced Materials, Division of Prosthodontics-Biomaterials, Federal University of Santa Maria (UFSM), Santa Maria, Brazil
| | - Lucas Saldanha da Rosa
- Post-Graduate Program in Oral Sciences, Center for Development of Advanced Materials, Division of Prosthodontics-Biomaterials, Federal University of Santa Maria (UFSM), Santa Maria, Brazil
| | - Gabriel Kalil Rocha Pereira
- Post-Graduate Program in Oral Sciences, Center for Development of Advanced Materials, Division of Prosthodontics-Biomaterials, Federal University of Santa Maria (UFSM), Santa Maria, Brazil
| | | | | |
Collapse
|
3
|
Munoz A, Zhao Z, Paolone G, Louca C, Vichi A. Flexural Strength of CAD/CAM Lithium-Based Silicate Glass-Ceramics: A Narrative Review. MATERIALS (BASEL, SWITZERLAND) 2023; 16:4398. [PMID: 37374581 DOI: 10.3390/ma16124398] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/11/2023] [Revised: 06/01/2023] [Accepted: 06/09/2023] [Indexed: 06/29/2023]
Abstract
Amongst chairside CAD/CAM materials, the use of lithium-based silicate glass-ceramics (LSGC) for indirect restorations has recently been increasing. Flexural strength is one of the most important parameters to consider in the clinical selection of materials. The aim of this paper is to review the flexural strength of LSGC and the methods used to measure it. METHODS The electronic search was completed within PubMed database from 2 June 2011 to 2 June 2022. English-language papers investigating the flexural strength of IPS e.max CAD, Celtra Duo, Suprinity PC, and n!ce CAD/CAM blocks were included in the search strategy. RESULTS From 211 potential articles, a total of 26 were identified for a comprehensive analysis. Categorization per material was carried out as follows: IPS e.max CAD (n = 27), Suprinity PC (n = 8), Celtra Duo (n = 6), and n!ce (n = 1). The three-point bending test (3-PBT) was used in 18 articles, followed by biaxial flexural test (BFT) in 10 articles, with one of these using the four-point bending test (4-PBT) as well. The most common specimen dimension was 14 × 4 × 1.2 mm (plates) for the 3-PBT and 12 × 1.2 mm (discs) for BFT. The flexural strength values for LSGC materials varied widely between the studies. SIGNIFICANCE As new LSGC materials are launched on the market, clinicians need to be aware of their flexural strength differences, which could influence the clinical performance of restorations.
Collapse
Affiliation(s)
- Alvaro Munoz
- Faculty of Dentistry, University of Chile, Santiago 8380544, Chile
| | - Zejiao Zhao
- Dental Academy, University of Portsmouth, Portsmouth PO1 2QG, UK
| | - Gaetano Paolone
- Dental School, IRCCS San Raffaele Hospital, Vita-Salute University, 20132 Milan, Italy
| | - Chris Louca
- Dental Academy, University of Portsmouth, Portsmouth PO1 2QG, UK
| | - Alessandro Vichi
- Dental Academy, University of Portsmouth, Portsmouth PO1 2QG, UK
| |
Collapse
|
4
|
Adabo GL, Longhini D, Baldochi MR, Bergamo ETP, Bonfante EA. Reliability and lifetime of lithium disilicate, 3Y-TZP, and 5Y-TZP zirconia crowns with different occlusal thicknesses. Clin Oral Investig 2023:10.1007/s00784-023-05001-6. [PMID: 37022529 DOI: 10.1007/s00784-023-05001-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2022] [Accepted: 03/28/2023] [Indexed: 04/07/2023]
Abstract
OBJECTIVES To assess the probability of survival of crowns made with a 3Y-TZP, a 5Y-TZP, and a lithium disilicate. MATERIALS AND METHODS CAD-CAM premolar crowns with occlusal thicknesses of 1.0 mm or 1.5 mm and cemented on a metal dye. Step-stress accelerated life testing (SSALT) was performed to access the use level probability Weibull curves and reliability were calculated for the completion of a mission of 100,000 cycles at 300 to 1200 N. RESULTS All ceramics showed a high probability of survival (87-99%) at 300 N, irrespective of thickness. 3Y-TZP shows no significant decrease in the probability of survival up to 1200 N (83-96%). Lithium disilicate presented lower reliability than zirconia under the 600 N mission. 5Y-TZP showed lower reliability than 3Y-TZP at 1200 N. There was no significant difference in the Weibull modulus (3.23-7.12). 3Y-TZP had the highest characteristic strength (2483-2972 N), followed by 5Y-TZP (1512-1547 N) and lithium disilicate (971-1154 N). CONCLUSION Zirconia ceramics have a high probability of survival (up to 900 N-load), while lithium disilicate survives up to 300 N load only, irrespective of the thickness (1.0 mm or 1.5 mm). CLINICAL RELEVANCE The probability of survival of posterior crowns made with zirconia ceramics resists extreme loads while glass ceramics resist normal chewing loads. In addition, crowns with thinner occlusal face showed sufficient mechanical behavior.
Collapse
Grants
- 2016/09640-0, 2012/19078-7, 2021/06730-7, EMU 2016/18818-8, 2019/08693-1 Fundação de Amparo à Pesquisa do Estado de São Paulo
- 2016/09640-0, 2012/19078-7, 2021/06730-7, EMU 2016/18818-8, 2019/08693-1 Fundação de Amparo à Pesquisa do Estado de São Paulo
- 2016/09640-0, 2012/19078-7, 2021/06730-7, EMU 2016/18818-8, 2019/08693-1 Fundação de Amparo à Pesquisa do Estado de São Paulo
- Finance Code 001 Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
- Finance Code 001 Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
- 307255/2021-2 Conselho Nacional de Desenvolvimento Científico e Tecnológico
Collapse
Affiliation(s)
- Gelson Luis Adabo
- School of Dentistry, Sao Paulo State University (Unesp), Araraquara, Sao Paulo, Brazil.
| | - Diogo Longhini
- School of Dentistry, Sao Paulo State University (Unesp), Araraquara, Sao Paulo, Brazil
| | | | | | | |
Collapse
|
5
|
da Silva AO, Fiorin L, Faria ACL, Ribeiro RF, Rodrigues RCS. Translucency and mechanical behavior of partially stabilized monolithic zirconia after staining, finishing procedures and artificial aging. Sci Rep 2022; 12:16094. [PMID: 36167885 PMCID: PMC9515067 DOI: 10.1038/s41598-022-20120-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2022] [Accepted: 09/08/2022] [Indexed: 11/09/2022] Open
Abstract
Partially stabilized zirconia (5Y-PSZ) has been widely used to manufacture indirect monolithic restorations, and the effect of finishing procedures on the optical and mechanical properties of these materials are still unclear. The purpose of this study was to evaluate the effect of staining, polishing and glazing on surface roughness, crystalline phase content, microhardness, fracture toughness, dynamic elastic modulus, three-point flexural strength, strain distribution, color (∆E00/∆L/∆a/∆b), and translucency before and after artificial accelerated aging (water spray and ultraviolet) of 5Y-PSZ. Bar-shaped and rectangle-shaped specimens of the 5Y-PSZ were prepared and divided into six groups, according to finishing procedure: GC (control), GS (staining), GG (glazing), GSG (staining and glazing), GP (polishing), GSP (staining and polishing). There was a significant difference between groups for surface roughness (p < 0.05), dynamic elastic modulus (p = 0.007), microhardness (p = < 0.05), ∆E00 (p = 0.010), and ∆a (p = 0.008). GC presented higher cubic phase content, and the stained groups (GS, GSG and GSP) presented higher monoclinic content. The different finishing procedures affected roughness, dynamic elastic modulus, microhardness, and color of 5Y-PSZ; polishing being the finish that provides minors changes to the 5Y- PSZ. Accelerated artificial aging caused color change, regardless of finishing procedure used.
Collapse
Affiliation(s)
- Allan Oliveira da Silva
- Department of Dental Materials and Prosthesis, School of Dentistry of Ribeirão Preto, University of São Paulo (USP), Ribeirão Preto, SP, Brazil
| | - Lívia Fiorin
- Department of Dental Materials and Prosthesis, School of Dentistry of Ribeirão Preto, University of São Paulo (USP), Ribeirão Preto, SP, Brazil
| | - Adriana Claudia Lapria Faria
- Department of Dental Materials and Prosthesis, School of Dentistry of Ribeirão Preto, University of São Paulo (USP), Ribeirão Preto, SP, Brazil
| | - Ricardo Faria Ribeiro
- Department of Dental Materials and Prosthesis, School of Dentistry of Ribeirão Preto, University of São Paulo (USP), Ribeirão Preto, SP, Brazil
| | - Renata Cristina Silveira Rodrigues
- Department of Dental Materials and Prosthesis, School of Dentistry of Ribeirão Preto, University of São Paulo (USP), Av. do Café, s/n, Ribeirão Preto, SP, 14040-904, Brazil.
| |
Collapse
|
6
|
Wear Behavior of Different Generations of Zirconia: Present Literature. Int J Dent 2022; 2022:9341616. [PMID: 35295406 PMCID: PMC8920625 DOI: 10.1155/2022/9341616] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2021] [Revised: 01/16/2022] [Accepted: 02/10/2022] [Indexed: 12/22/2022] Open
Abstract
Objective. The wear behavior of the novel zirconia generation is less well understood and may be affected by compositional modifications compared to the conventional zirconia. Materials and Methods. Combinations of keywords such as “zirconia,” “high translucent,” and “wear” were searched in PubMed and Google Scholar databases up to May 2021. The total of 23 relevant articles was selected according to inclusion criteria. Results. Reports show comparable wear resistance of translucent zirconia to the conventional zirconia despite an increased cubic phase content and lower mean flexural strength. A meticulously polished surface creates the lowest surface roughness, producing favorable zirconia wear resistance and antagonist wear compared to a glazed surface. In comparison to other ceramic materials, zirconia produces the least wear on an enamel antagonist and almost undetectable wear when opposed by zirconia. Wear when paired against resin materials yields a favorable outcome, whereas wear behavior against a metal antagonist varies with the surface hardness of the metal. Conclusions. All zirconia generations are considered wear-friendly to all types of antagonists. Nonetheless, comparative studies on antagonist wear opposing zirconia of different compositions are still limited and further investigation is required.
Collapse
|
7
|
Clinical Evaluation of Reduced-Thickness Monolithic Lithium-Disilicate Crowns: One-Year Follow-Up Results. Processes (Basel) 2021. [DOI: 10.3390/pr9122119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Purpose: The purpose of this in vivo study was to investigate whether the less invasive approach (reduced thickness of the restoration) will result in a comparable risk of failure and similar aesthetic results, compared to conventional layered full porcelain crowns, and can, therefore, be used as a good alternative. Material and Methods: The tested ceramic was lithium-disilicate ceramic (IPS e.max). Forty-four patients with endodontically treated premolars or molars were randomized into two groups and provided with single crowns. One group received conventional all-ceramic crowns made from a lithium-disilicate core and hand-veneered aesthetic ceramic, while another group received full-contoured lithium-disilicate ceramic crowns with reduced wall thickness than manufactures recommendations. The teeth for conventional crowns were prepared with 1 mm rounded shoulder and 2 mm occlusal reduction, while teeth for monolithic crowns were prepared with 0.6 mm wide rounded shoulder and 1 mm occlusal reduction. All crowns were prepared by the same clinician and manufactured in the same laboratory by the same technician. The survival and aesthetics of the crowns were assessed by the independent clinician. Apart from this, patients’ aesthetic satisfaction was evaluated. The assessment was double blind as both the examiner and the patients did not know which type of crown was provided. The observation period was 36 months. Survival of the crowns was assessed using the modified United States Public Health Service (USPHS) criteria and aesthetics and participants’ aesthetic satisfaction with the crowns was evaluated using a visual analogue scale. Results: The one-year survival rate for layered crowns was 100% and for monolithic crowns 95.5%. The median patients’ aesthetic satisfaction with both crowns was 100%. Conclusions: The results indicate similar one-year survival rate of reduced-thickness monolithic lithium-disilicate crowns and conventional veneered crowns. Differences with patients’ satisfaction with the aesthetics of both crowns were not statistically significant and it can be said that the patients’ aesthetic satisfaction was the same for both crowns.
Collapse
|
8
|
Machry RV, Cadore-Rodrigues AC, Borges ALS, Pereira GK, Kleverlaan CJ, Venturini AB, Valandro LF. Fatigue resistance of simplified CAD–CAM restorations: Foundation material and ceramic thickness effects on the fatigue behavior of partially- and fully-stabilized zirconia. Dent Mater 2021; 37:568-577. [DOI: 10.1016/j.dental.2021.01.001] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2020] [Revised: 10/15/2020] [Accepted: 01/09/2021] [Indexed: 10/22/2022]
|
9
|
Van den Breemer CRG, Buijs GJ, Cune MS, Özcan M, Kerdijk W, Van der Made S, Gresnigt MMM. Prospective clinical evaluation of 765 partial glass-ceramic posterior restorations luted using photo-polymerized resin composite in conjunction with immediate dentin sealing. Clin Oral Investig 2020; 25:1463-1473. [PMID: 32785851 PMCID: PMC7878261 DOI: 10.1007/s00784-020-03454-7] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2018] [Accepted: 07/07/2020] [Indexed: 11/19/2022]
Abstract
Objectives To evaluate the clinical performance of partial glass-ceramic (IPS e.max Press) posterior restorations. Materials and methods A total of 765 restorations in 158 patients were placed between 2008 and 2018 and evaluated in a prospective study during regular dental care visits between 2015 and 2018. The restorations were luted with a conventional photo-polymerized resin composite (HFO) in conjunction with an Immediate Dentin Sealing procedure (IDS). Intra-oral photographs and radiographs were made and evaluated using USPHS criteria. Results The mean observation time was 53.3 months (range 3–113 months). Three absolute failures occurred (tooth fractures, n = 2; apical re-infection, n = 1) all leading to the loss of the restored tooth. Repairable and salvageable failures occurred in 9 teeth (endodontic complications, n = 7; secondary caries, n = 1; debonding, n = 1). The survival and success rates according to Kaplan-Meier after 5 years cumulated to 99.6% and 98.6%, respectively. Location (premolar/molar and mandibula/maxilla), pre-restorative endodontic status (vital/devitalised) and extension of the indirect ceramic restoration (number of sides and cusps involved) did not significantly affect the cumulative success rate (log rank test, p > 0.05). The condition of the vast majority of the restorations remained unaffected for 5 years. Conclusions Partial glass-ceramic posterior restorations (pressed lithium disilicate (IPS e.max press, Ivoclar Vivadent) luted by means of a conventional photo-polymerized resin composite in conjunction with the use of an IDS procedure have an excellent medium-term prognosis. Clinical relevance Partial glass-ceramic posterior restorations can be considered as a highly reliable treatment option. Location and extension of the restoration and pre-restorative endodontic status do not affect success rate.
Collapse
Affiliation(s)
- Carline R G Van den Breemer
- Department of Restorative Dentistry and Biomaterials, Center for Dentistry and Oral Hygiene, University Medical Center Groningen, Antonius Deusinglaan 1, 9713, AV, Groningen, The Netherlands.
| | | | - Marco S Cune
- Department of Restorative Dentistry and Biomaterials, Center for Dentistry and Oral Hygiene, University Medical Center Groningen, Antonius Deusinglaan 1, 9713, AV, Groningen, The Netherlands.,Department of Oral-Maxillofacial Surgery, Prosthodontics and Special Dental Care, St. Antonius Hospital Nieuwegein, Nieuwegein, The Netherlands.,Department of Oral Maxillofacial Surgery, Prosthodontics and Special Dental Care, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Mutlu Özcan
- Division of Dental Materials, Center for Dental and Oral Medicine, Clinic for Fixed and Removable Prosthodontics and Dental Materials Science, University of Zurich, Zurich, Switzerland
| | - Wouter Kerdijk
- Department of Education and Research, Hanze University of Applied Sciences, Groningen, The Netherlands
| | | | - Marco M M Gresnigt
- Department of Restorative Dentistry and Biomaterials, Center for Dentistry and Oral Hygiene, University Medical Center Groningen, Antonius Deusinglaan 1, 9713, AV, Groningen, The Netherlands.,Department of Special Care, Martini Hospital, Groningen, The Netherlands
| |
Collapse
|