1
|
Abuqbeitah M, Sağer S, Demir M, Yeyin N, Akovalı B, Sönmezoğlu K. The impact of different computational assumptions in
131
I dosimetry for hyperthyroidism therapy. Med Phys 2020; 47:5810-5816. [DOI: 10.1002/mp.14478] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2020] [Revised: 07/21/2020] [Accepted: 08/10/2020] [Indexed: 11/09/2022] Open
Affiliation(s)
- Mohammad Abuqbeitah
- Nuclear Medicine Department Istanbul University‐CerrahpasaCerrahpasa Medical School Istanbul Fatih0090 Turkey
| | - Sait Sağer
- Nuclear Medicine Department Istanbul University‐CerrahpasaCerrahpasa Medical School Istanbul Fatih0090 Turkey
| | - Mustafa Demir
- Nuclear Medicine Department Istanbul University‐CerrahpasaCerrahpasa Medical School Istanbul Fatih0090 Turkey
| | - Nami Yeyin
- Nuclear Medicine Department Istanbul University‐CerrahpasaCerrahpasa Medical School Istanbul Fatih0090 Turkey
| | - Burak Akovalı
- Nuclear Medicine Department Istanbul University‐CerrahpasaCerrahpasa Medical School Istanbul Fatih0090 Turkey
| | - Kerim Sönmezoğlu
- Nuclear Medicine Department Istanbul University‐CerrahpasaCerrahpasa Medical School Istanbul Fatih0090 Turkey
| |
Collapse
|
2
|
Gosewisch A, Ilhan H, Tattenberg S, Mairani A, Parodi K, Brosch J, Kaiser L, Gildehaus FJ, Todica A, Ziegler S, Bartenstein P, Böning G. 3D Monte Carlo bone marrow dosimetry for Lu-177-PSMA therapy with guidance of non-invasive 3D localization of active bone marrow via Tc-99m-anti-granulocyte antibody SPECT/CT. EJNMMI Res 2019; 9:76. [PMID: 31414241 PMCID: PMC6694348 DOI: 10.1186/s13550-019-0548-z] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2019] [Accepted: 07/30/2019] [Indexed: 11/15/2022] Open
Abstract
BACKGROUND The bone marrow (BM) is a main risk organ during Lu-177-PSMA ligand therapy of metastasized castration-resistant prostate cancer (mCRPC) patients. So far, BM dosimetry relies on S values, which are pre-computed for reference anatomies, simplified activity distributions, and a physiological BM distribution. However, mCRPC patients may show a considerable bone lesion load, which leads to a heterogeneous and patient-specific activity accumulation close to BM-bearing sites. Furthermore, the patient-specific BM distribution might be significantly altered in the presence of bone lesions. The aim was to perform BM absorbed dose calculations through Monte Carlo (MC) simulations and to investigate the potential value of image-based BM localization. This study is based on 11 Lu-177-PSMA-617 therapy cycles of 10 patients (10 first cycles), who obtained a pre-therapeutic Ga-68-PSMA-11 PET/CT; quantitative Lu-177 SPECT acquisitions of the abdomen 24 (+CT), 48, and 72 h p.i.; and a Lu-177 whole-body planar acquisition at 24 h post-therapy. Patient-specific 3D volumes of interest were segmented from the Ga-68-PSMA-11 PET/CT, filled with activity information from the Lu-177 data, and imported into the FLUKA MC code together with the patient CT. MC simulations of the BM absorbed dose were performed assuming a physiological BM distribution according to the ICRP 110 reference male (MC1) or a displacement of active BM from the direct location of bone lesions (MC2). Results were compared with those from S values (SMIRD). BM absorbed doses were correlated with the decrease of lymphocytes, total white blood cells, hemoglobin level, and platelets. For two patients, an additional pre-therapeutic Tc-99m-anti-granulocyte antibody SPECT/CT was performed for BM localization. RESULTS Median BM absorbed doses were 130, 37, and 11 mGy/GBq for MC1, MC2, and SMIRD, respectively. Significant strong correlation with the decrease of platelet counts was found, with highest correlation for MC2 (MC1: r = - 0.63, p = 0.04; MC2: r = - 0.71, p = 0.01; SMIRD: r = - 0.62, p = 0.04). For both investigated patients, BM localization via Tc-99m-anti-granulocyte antibody SPECT/CT indicated a displacement of active BM from the direct location of lesions similar to model MC2 and led to a reduction in the BM absorbed dose of 40 and 41% compared to MC1. CONCLUSION Higher BM absorbed doses were observed for MC-based models; however, for MC2, all absorbed doses were still below 2 Gy. MC1 resulted in critical values for some patients, but is suspected to yield strongly exaggerated absorbed doses by neglecting bone marrow displacement. Image-based BM localization might be beneficial, and future studies are recommended to support an improvement for the prediction of hematoxicities.
Collapse
Affiliation(s)
- Astrid Gosewisch
- Department of Nuclear Medicine, University Hospital, LMU Munich, Marchioninistrasse 15, 81377 Munich, Germany
| | - Harun Ilhan
- Department of Nuclear Medicine, University Hospital, LMU Munich, Marchioninistrasse 15, 81377 Munich, Germany
| | - Sebastian Tattenberg
- Department of Nuclear Medicine, University Hospital, LMU Munich, Marchioninistrasse 15, 81377 Munich, Germany
| | - Andrea Mairani
- Heidelberg Ion Beam Therapy Center, University Hospital Heidelberg, Heidelberg, Germany
| | - Katia Parodi
- Department of Medical Physics, Ludwig-Maximilians-Universität München, Garching b. München, Germany
| | - Julia Brosch
- Department of Nuclear Medicine, University Hospital, LMU Munich, Marchioninistrasse 15, 81377 Munich, Germany
| | - Lena Kaiser
- Department of Nuclear Medicine, University Hospital, LMU Munich, Marchioninistrasse 15, 81377 Munich, Germany
| | - Franz Josef Gildehaus
- Department of Nuclear Medicine, University Hospital, LMU Munich, Marchioninistrasse 15, 81377 Munich, Germany
| | - Andrei Todica
- Department of Nuclear Medicine, University Hospital, LMU Munich, Marchioninistrasse 15, 81377 Munich, Germany
| | - Sibylle Ziegler
- Department of Nuclear Medicine, University Hospital, LMU Munich, Marchioninistrasse 15, 81377 Munich, Germany
| | - Peter Bartenstein
- Department of Nuclear Medicine, University Hospital, LMU Munich, Marchioninistrasse 15, 81377 Munich, Germany
| | - Guido Böning
- Department of Nuclear Medicine, University Hospital, LMU Munich, Marchioninistrasse 15, 81377 Munich, Germany
| |
Collapse
|
3
|
Gosewisch A, Delker A, Tattenberg S, Ilhan H, Todica A, Brosch J, Vomacka L, Brunegraf A, Gildehaus FJ, Ziegler S, Bartenstein P, Böning G. Patient-specific image-based bone marrow dosimetry in Lu-177-[DOTA 0,Tyr 3]-Octreotate and Lu-177-DKFZ-PSMA-617 therapy: investigation of a new hybrid image approach. EJNMMI Res 2018; 8:76. [PMID: 30076556 PMCID: PMC6081875 DOI: 10.1186/s13550-018-0427-z] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2018] [Accepted: 07/16/2018] [Indexed: 12/22/2022] Open
Abstract
BACKGROUND The bone marrow (BM) is a main organ at risk in Lu-177-PSMA-617 therapy of prostate cancer and Lu-177-Octreotate therapy of neuroendocrine tumours. BM dosimetry is challenging and time-consuming, as different sequential quantitative measurements must be combined. The BM absorbed dose from the remainder of the body (ROB) can be determined from sequential whole-body planar (WB-P) imaging, while quantitative Lu-177-SPECT allows for more robust tumour and organ absorbed doses. The aim was to investigate a time-efficient and patient-friendly hybrid protocol (HP) for the ROB absorbed dose to the BM. It combines three abdominal quantitative SPECT (QSPECT) scans with a single WB-P acquisition and was compared with a reference protocol (RP) using sequential WB-P in combination with sequential QSPECT images. We investigated five patients receiving 7.4 GBq Lu-177-Octreotate and five patients treated with 3.7 GBq Lu-177-PSMA-617. Each patient had WB-P and abdominal SPECT acquisitions 24 (+ CT), 48, and 72 h post-injection. Blood samples were drawn 30 min, 80 min, 24 h, 48 h, and 72 h post-injection. BM absorbed doses from the ROB were estimated from sequential WB-P images (RP), via a mono-exponential fit and mass-scaled organ-level S values. For the HP, a mono-exponential fit on the QSPECT data was scaled with the activity of one WB-P image acquired either 24, 48, or 72 h post-injection (HP24, HP48, HP72). Total BM absorbed doses were determined as a sum of ROB, blood, major organ, and tumour contributions. RESULTS Compared with the RP and for Lu-177-Octreotate therapy, median differences of the total BM absorbed doses were 13% (9-17%), 8% (4-15%), and 1% (0-5%) for the HP24, HP48, and HP72, respectively. For Lu-177-PSMA-617 therapy, total BM absorbed doses deviated 10% (2-20%), 3% (0-6%), and 2% (0-6%). CONCLUSION For both Lu-177-Octreotate and Lu-177-PSMA-617 therapy, BM dosimetry via sequential QSPECT imaging and a single WB-P acquisition is feasible, if this WB-P image is acquired at a late time point (48 or 72 h post-injection). The reliability of the HP can be well accepted considering the uncertainties of quantitative Lu-177 imaging and BM dosimetry using standardised organ-level S values.
Collapse
Affiliation(s)
- Astrid Gosewisch
- Department of Nuclear Medicine, University Hospital, LMU Munich, Marchioninistrasse 15, 81377 Munich, Germany
| | - Andreas Delker
- Department of Nuclear Medicine, University Hospital, LMU Munich, Marchioninistrasse 15, 81377 Munich, Germany
| | - Sebastian Tattenberg
- Department of Nuclear Medicine, University Hospital, LMU Munich, Marchioninistrasse 15, 81377 Munich, Germany
| | - Harun Ilhan
- Department of Nuclear Medicine, University Hospital, LMU Munich, Marchioninistrasse 15, 81377 Munich, Germany
| | - Andrei Todica
- Department of Nuclear Medicine, University Hospital, LMU Munich, Marchioninistrasse 15, 81377 Munich, Germany
| | - Julia Brosch
- Department of Nuclear Medicine, University Hospital, LMU Munich, Marchioninistrasse 15, 81377 Munich, Germany
| | - Lena Vomacka
- Department of Nuclear Medicine, University Hospital, LMU Munich, Marchioninistrasse 15, 81377 Munich, Germany
| | - Anika Brunegraf
- Department of Nuclear Medicine, University Hospital, LMU Munich, Marchioninistrasse 15, 81377 Munich, Germany
| | - Franz Josef Gildehaus
- Department of Nuclear Medicine, University Hospital, LMU Munich, Marchioninistrasse 15, 81377 Munich, Germany
| | - Sibylle Ziegler
- Department of Nuclear Medicine, University Hospital, LMU Munich, Marchioninistrasse 15, 81377 Munich, Germany
| | - Peter Bartenstein
- Department of Nuclear Medicine, University Hospital, LMU Munich, Marchioninistrasse 15, 81377 Munich, Germany
| | - Guido Böning
- Department of Nuclear Medicine, University Hospital, LMU Munich, Marchioninistrasse 15, 81377 Munich, Germany
| |
Collapse
|
4
|
Hesterman JY, Kost SD, Holt RW, Dobson H, Verma A, Mozley PD. Three-Dimensional Dosimetry for Radiation Safety Estimates from Intrathecal Administration. J Nucl Med 2017; 58:1672-1678. [PMID: 28336783 DOI: 10.2967/jnumed.117.190611] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2017] [Accepted: 03/13/2017] [Indexed: 11/16/2022] Open
Abstract
Intrathecal administration is of growing interest for drug delivery, and its utility is being increasingly investigated through imaging. In this work, the 3-dimensional Voxel-Based Internal Dosimetry Application (VIDA) and 4D Extended Cardiac Torso Phantom (XCAT) were extended to provide radiation safety estimates specific to intrathecal administration. Methods: The 3-dimensional VIDA dosimetry application Monte Carlo simulation was run using a modified XCAT phantom with additional and edited cerebrospinal fluid (CSF) regions to produce voxel-level absorbed dose per unit cumulated activity maps for 9 selected source regions. Simulation validation was performed to compare absorbed dose estimates for common organs in a preexisting dosimetry tool (OLINDA/EXM). Dynamic planar imaging data were acquired in 6 healthy subjects using administered volumes of 5 or 15 mL (n = 3 each) of 185 MBq of 99mTc-diethylenetriaminepentaacetic acid. Absorbed dose was estimated for each subject using the intrathecal-specific dosimetry application. Results: Simulation results were within 6% of OLINDA estimates for common organs. Absorbed dose estimates were highest (0.3-0.8 mGy/MBq) in the lumbar CSF space. A whole-body effective dose estimate of 0.003 mSv/MBq was observed. An administered volume dependency was observed with a 15-mL volume, resulting in lower absorbed dose estimates for several intrathecal and nonintrathecal regions. Conclusion: The intrathecal-specific VIDA implementation enables tailored dosimetry estimation for regions most relevant in intrathecal administration. Absorbed doses are highly localized to CSF and spinal regions and should be taken into consideration when designing intrathecal imaging studies. A potentially interesting relationship was observed between absorbed dose and administered volume, which merits further investigation.
Collapse
Affiliation(s)
| | | | | | | | | | - P David Mozley
- Weill Cornell Graduate College of Medical Sciences, New York, New York
| |
Collapse
|
5
|
Dosimetric evaluation of 153Sm-EDTMP, 177Lu-EDTMP and 166Ho-EDTMP for systemic radiation therapy: Influence of type and energy of radiation and half-life of radionuclides. Radiat Phys Chem Oxf Engl 1993 2015. [DOI: 10.1016/j.radphyschem.2014.11.015] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
6
|
Mínguez P, Genolla J, Celeiro JJ, Fombellida JC. Dosimetry in differentiated thyroid carcinoma. Med Phys 2012; 40:012502. [DOI: 10.1118/1.4769426] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
7
|
Wierts R, de Pont CD, Brans B, Mottaghy FM, Kemerink GJ. Dosimetry in molecular nuclear therapy. Methods 2011; 55:196-202. [DOI: 10.1016/j.ymeth.2011.09.016] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2011] [Revised: 09/11/2011] [Accepted: 09/13/2011] [Indexed: 01/06/2023] Open
|
8
|
Bouchat V, Nuttens VE, Michiels C, Masereel B, Feron O, Gallez B, Vander Borght T, Lucas S. Radioimmunotherapy with radioactive nanoparticles: biological doses and treatment efficiency for vascularized tumors with or without a central hypoxic area. Med Phys 2010; 37:1826-39. [PMID: 20443505 DOI: 10.1118/1.3368599] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE Radioactive atoms attached to monoclonal antibodies are used in radioimmunotherapy to treat cancer while limiting radiation to healthy tissues. One limitation of this method is that only one radioactive atom is linked to each antibody and the deposited dose is often insufficient to eradicate solid and radioresistant tumors. In a previous study, simulations with the Monte Carlo N-Particle eXtended code showed that physical doses up to 50 Gy can be delivered inside tumors by replacing the single radionuclide by a radioactive nanoparticle of 5 nm diameter containing hundreds of radioactive atoms. However, tumoral and normal tissues are not equally sensitive to radiation, and previous works did not take account the biological effects such as cellular repair processes or the presence of less radiosensitive cells such as hypoxic cells. METHODS The idea is to adapt the linear-quadratic expression to the tumor model and to determine biological effective doses (BEDs) delivered through and around a tumor. This BED is then incorporated into a Poisson formula to determine the shell control probability (SCP) which predicts the cell cluster-killing efficiency at different distances "r" from the center of the tumor. BED and SCP models are used to analyze the advantages of injecting radioactive nanoparticles instead of a single radionuclide per vector in radioimmunotherapy. RESULTS Calculations of BED and SCP for different distances r from the center of a solid tumor, using the non-small-cell lung cancer as an example, were investigated for 90Y2O3 nanoparticles. With a total activity of about 3.5 and 20 MBq for tumor radii of 0.5 and 1.0 cm, respectively, results show that a very high BED is deposited in the well oxygenated part of the spherical carcinoma. CONCLUSIONS For either small or large solid tumors, BED and SCP calculations highlight the important benefit in replacing the single beta-emitter 90Y attached to each antibody by a 90Y2O3 nanoparticle.
Collapse
Affiliation(s)
- V Bouchat
- Research Center in Physics of Matter and Radiation, Laboratoire d'Analyses par Réactions Nucléaires, University of Namur, Rue de Bruxelles 61, B-5000 Namur, Belgium.
| | | | | | | | | | | | | | | |
Collapse
|
9
|
Abstract
The development of patient-specific treatment planning systems is of outmost importance in the development of radionuclide dosimetry, taking into account that quantitative three-dimensional nuclear medical imaging can be used in this regard. At present, the established method for dosimetry is based on the measurement of the biokinetics by serial gamma-camera scans, followed by calculations of the administered activity and the residence times, resulting in the radiation-absorbed doses of critical organs. However, the quantification of the activity in different organs from planar data is hampered by inaccurate attenuation and scatter correction as well as because of background and organ overlay. In contrast, dosimetry based on quantitative three-dimensional data can be more accurate and allows an individualized approach, provided that all effects that degrade the quantitative content of the images have been corrected for. In addition, inhomogeneous organ accumulation of the radionuclide can be detected and possibly taken into account. The aim of this work is to provide adequate information on internal emitter dosimetry and a state-of-the-art review of the current methodology and future trends.
Collapse
|
10
|
Coleman RE, Stubbs JB, Barrett JA, de la Guardia M, LaFrance N, Babich JW. Radiation Dosimetry, Pharmacokinetics, and Safety of Ultratrace™ Iobenguane I-131 in Patients with Malignant Pheochromocytoma/Paraganglioma or Metastatic Carcinoid. Cancer Biother Radiopharm 2009; 24:469-75. [DOI: 10.1089/cbr.2008.0584] [Citation(s) in RCA: 48] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Affiliation(s)
- R. Edward Coleman
- Division of Nuclear Medicine, Duke University Medical Center, Durham, North Carolina
| | | | - John A. Barrett
- Molecular Insight Pharmaceuticals, Inc., Cambridge, Massachusetts
| | | | - Norman LaFrance
- Molecular Insight Pharmaceuticals, Inc., Cambridge, Massachusetts
| | - John W. Babich
- Molecular Insight Pharmaceuticals, Inc., Cambridge, Massachusetts
| |
Collapse
|