1
|
Abbasvandi F, Miripour ZS, Bayat M, Mousavi-Kiasary SMS, Shayanfar S, Shojaeian F, Aghaei F, Jahanbakhshi F, Abbasvandi N, Omranihashemi M, Akbari A, Yousefi M, Hadizadeh M, Farahani NS, Hosseinpoor P, Parniani M, Nourinjad Z, Abdolahad M, Akbari ME. Clinical validation on role of cancer diagnostic probe in detecting the involved cavity margins missed in permanent pathology of tumor side in breast cancer surgery. Diagn Pathol 2024; 19:148. [PMID: 39568025 PMCID: PMC11577628 DOI: 10.1186/s13000-024-01574-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2023] [Accepted: 11/04/2024] [Indexed: 11/22/2024] Open
Abstract
Cancer diagnostic probe (CDP) as a newly entered tool in real-time breast cavity margin evaluation showed great improvement in smart margin shaving intra-operatively. This system increased the rate of involved margin detection to 30% with respect to frozen section. In this study for the first time we showed the independent role of CDP in finding the involved cavity side margins which were not diagnosed by permananet pathology of their tumor side interface. Among 147 detected margins by CDP, 23 lesions with invasive component and ductal carcinoma in-situ/ductal cancerization weren't reported as involved margins in permanent pathology of tumor side. Our gold standard was the histology of cavity margin specimen had been scored as involved lesion by CDP. It seems that even when the permanent pathology of surgical margins is used for final declaration, role of CDP is irreplaceable. This distinguished achievement has been obtained intra-operatively in real-time by CDP while involved report in permanent pathology of tumor margins induce re-surgery for the patient.
Collapse
MESH Headings
- Humans
- Breast Neoplasms/pathology
- Breast Neoplasms/surgery
- Female
- Margins of Excision
- Frozen Sections
- Middle Aged
- Aged
- Carcinoma, Intraductal, Noninfiltrating/surgery
- Carcinoma, Intraductal, Noninfiltrating/pathology
- Carcinoma, Ductal, Breast/surgery
- Carcinoma, Ductal, Breast/pathology
- Mastectomy, Segmental
- Adult
- Neoplasm, Residual
Collapse
Affiliation(s)
- Fereshteh Abbasvandi
- Nano Bioelectronics Devices Lab, Cancer Electronics Research Group, School of Electrical and Computer Engineering, Faculty of Engineering, University of Tehran, 4563-11155, Tehran, Iran
- ATMP Department, Breast Cancer Research Center, Motamed Cancer Institute, ACECR, 1517964311, Tehran, Iran
- Cancer Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Zohreh Sadat Miripour
- Nano Bioelectronics Devices Lab, Cancer Electronics Research Group, School of Electrical and Computer Engineering, Faculty of Engineering, University of Tehran, 4563-11155, Tehran, Iran
| | - Mahdis Bayat
- Nano Bioelectronics Devices Lab, Cancer Electronics Research Group, School of Electrical and Computer Engineering, Faculty of Engineering, University of Tehran, 4563-11155, Tehran, Iran
- Cancer Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Seyed Mohamad Sadegh Mousavi-Kiasary
- Nano Bioelectronics Devices Lab, Cancer Electronics Research Group, School of Electrical and Computer Engineering, Faculty of Engineering, University of Tehran, 4563-11155, Tehran, Iran
| | - Samira Shayanfar
- Cancer Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Fatemeh Shojaeian
- Nano Bioelectronics Devices Lab, Cancer Electronics Research Group, School of Electrical and Computer Engineering, Faculty of Engineering, University of Tehran, 4563-11155, Tehran, Iran
- Cancer Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Faeze Aghaei
- Nano Bioelectronics Devices Lab, Cancer Electronics Research Group, School of Electrical and Computer Engineering, Faculty of Engineering, University of Tehran, 4563-11155, Tehran, Iran
| | - Fahimeh Jahanbakhshi
- Nano Bioelectronics Devices Lab, Cancer Electronics Research Group, School of Electrical and Computer Engineering, Faculty of Engineering, University of Tehran, 4563-11155, Tehran, Iran
| | - Niloofar Abbasvandi
- Nano Bioelectronics Devices Lab, Cancer Electronics Research Group, School of Electrical and Computer Engineering, Faculty of Engineering, University of Tehran, 4563-11155, Tehran, Iran
- ATMP Department, Breast Cancer Research Center, Motamed Cancer Institute, ACECR, 1517964311, Tehran, Iran
| | - Maryam Omranihashemi
- Cancer Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Atieh Akbari
- Cancer Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Morteza Yousefi
- Cancer Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Mohammad Hadizadeh
- Nano Bioelectronics Devices Lab, Cancer Electronics Research Group, School of Electrical and Computer Engineering, Faculty of Engineering, University of Tehran, 4563-11155, Tehran, Iran
| | | | - Parisa Hosseinpoor
- Nano Bioelectronics Devices Lab, Cancer Electronics Research Group, School of Electrical and Computer Engineering, Faculty of Engineering, University of Tehran, 4563-11155, Tehran, Iran
- ATMP Department, Breast Cancer Research Center, Motamed Cancer Institute, ACECR, 1517964311, Tehran, Iran
- SEPAS Pathology Laboratory, Tehran, Iran
| | - Mohammad Parniani
- ATMP Department, Breast Cancer Research Center, Motamed Cancer Institute, ACECR, 1517964311, Tehran, Iran
| | - Zeinab Nourinjad
- ATMP Department, Breast Cancer Research Center, Motamed Cancer Institute, ACECR, 1517964311, Tehran, Iran
| | - Mohammad Abdolahad
- Nano Bioelectronics Devices Lab, Cancer Electronics Research Group, School of Electrical and Computer Engineering, Faculty of Engineering, University of Tehran, 4563-11155, Tehran, Iran.
- Cancer Institute, Imam-Khomeini Hospital, Tehran University of Medical Sciences, Tehran, Iran.
| | | |
Collapse
|
2
|
Byun YH, Won JK, Hong DH, Kang H, Kim JH, Yu MO, Kim MS, Kim YH, Park KJ, Jeong MJ, Hwang K, Kong DS, Park CK, Kang SH. A prospective multicenter assessor blinded pilot study using confocal laser endomicroscopy for intraoperative brain tumor diagnosis. Sci Rep 2024; 14:6784. [PMID: 38514670 PMCID: PMC10957981 DOI: 10.1038/s41598-024-52494-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2023] [Accepted: 01/19/2024] [Indexed: 03/23/2024] Open
Abstract
In this multi-center, assessor-blinded pilot study, the diagnostic efficacy of cCeLL-Ex vivo, a second-generation confocal laser endomicroscopy (CLE), was compared against the gold standard frozen section analysis for intraoperative brain tumor diagnosis. The study was conducted across three tertiary medical institutions in the Republic of Korea. Biopsy samples from newly diagnosed brain tumor patients were categorized based on location and divided for permanent section analysis, frozen section analysis, and cCeLL-Ex vivo imaging. Of the 74 samples from 55 patients, the majority were from the tumor core (74.3%). cCeLL-Ex vivo exhibited a relatively higher diagnostic accuracy (89.2%) than frozen section analysis (86.5%), with both methods showing a sensitivity of 92.2%. cCeLL-Ex vivo also demonstrated higher specificity (70% vs. 50%), positive predictive value (PPV) (95.2% vs. 92.2%), and negative predictive value (NPV) (58.3% vs. 50%). Furthermore, the time from sample preparation to diagnosis was notably shorter with cCeLL-Ex vivo (13 min 17 s) compared to frozen section analysis (28 min 28 s) (p-value < 0.005). These findings underscore cCeLL-Ex vivo's potential as a supplementary tool for intraoperative brain tumor diagnosis, with future studies anticipated to further validate its clinical utility.
Collapse
Affiliation(s)
- Yoon Hwan Byun
- Department of Neurosurgery, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea
| | - Jae-Kyung Won
- Department of Pathology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea
| | - Duk Hyun Hong
- Department of Neurosurgery, Korea University Hospital, Korea University College of Medicine, 73, Goryeodae-ro, Seongbuk-gu, Seoul, 02841, Republic of Korea
| | - Ho Kang
- Department of Neurosurgery, Seoul National University Bundang Hospital, Gyeonggi-Do, Republic of Korea
| | - Jang Hun Kim
- Department of Neurosurgery, Korea University Hospital, Korea University College of Medicine, 73, Goryeodae-ro, Seongbuk-gu, Seoul, 02841, Republic of Korea
| | - Mi Ok Yu
- Department of Neurosurgery, Korea University Hospital, Korea University College of Medicine, 73, Goryeodae-ro, Seongbuk-gu, Seoul, 02841, Republic of Korea
| | - Min-Sung Kim
- Department of Neurosurgery, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea
| | - Yong Hwy Kim
- Department of Neurosurgery, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea
| | - Kyung-Jae Park
- Department of Neurosurgery, Korea University Hospital, Korea University College of Medicine, 73, Goryeodae-ro, Seongbuk-gu, Seoul, 02841, Republic of Korea
| | | | | | - Doo-Sik Kong
- Department of Neurosurgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| | - Chul-Kee Park
- Department of Neurosurgery, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea
| | - Shin-Hyuk Kang
- Department of Neurosurgery, Korea University Hospital, Korea University College of Medicine, 73, Goryeodae-ro, Seongbuk-gu, Seoul, 02841, Republic of Korea.
| |
Collapse
|
3
|
Bonosi L, Marrone S, Benigno UE, Buscemi F, Musso S, Porzio M, Silven MP, Torregrossa F, Grasso G. Maximal Safe Resection in Glioblastoma Surgery: A Systematic Review of Advanced Intraoperative Image-Guided Techniques. Brain Sci 2023; 13:brainsci13020216. [PMID: 36831759 PMCID: PMC9954589 DOI: 10.3390/brainsci13020216] [Citation(s) in RCA: 21] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2022] [Revised: 01/15/2023] [Accepted: 01/24/2023] [Indexed: 01/31/2023] Open
Abstract
Glioblastoma multiforme (GBM) represents the most common and aggressive central nervous system tumor associated with a poor prognosis. The aim of this study was to depict the role of intraoperative imaging techniques in GBM surgery and how they can ensure the maximal extent of resection (EOR) while preserving the functional outcome. The authors conducted a systematic review following PRISMA guidelines on the PubMed/Medline and Scopus databases. A total of 1747 articles were identified for screening. Studies focusing on GBM-affected patients, and evaluations of EOR and functional outcomes with the aid of advanced image-guided techniques were included. The resulting studies were assessed for methodological quality using the Risk of Bias in Systematic Review tool. Open Science Framework registration DOI 10.17605/OSF.IO/3FDP9. Eighteen studies were eligible for this systematic review. Among the selected studies, eight analyzed Sodium Fluorescein, three analyzed 5-aminolevulinic acid, two evaluated IoMRI imaging, two evaluated IoUS, and three evaluated multiple intraoperative imaging techniques. A total of 1312 patients were assessed. Gross Total Resection was achieved in the 78.6% of the cases. Follow-up time ranged from 1 to 52 months. All studies assessed the functional outcome based on the Karnofsky Performance Status scale, while one used the Neurologic Assessment in Neuro-Oncology score. In 77.7% of the cases, the functional outcome improved or was stable over the pre-operative assessment. Combining multiple intraoperative imaging techniques could provide better results in GBM surgery than a single technique. However, despite good surgical outcomes, patients often present a neurocognitive decline leading to a marked deterioration of the quality of life. Advanced intraoperative image-guided techniques can allow a better understanding of the anatomo-functional relationships between the tumor and the surrounding brain, thus maximizing the EOR while preserving functional outcomes.
Collapse
|
4
|
Skyrman S, Burström G, Lai M, Manni F, Hendriks B, Frostell A, Edström E, Persson O, Elmi-Terander A. Diffuse reflectance spectroscopy sensor to differentiate between glial tumor and healthy brain tissue: a proof-of-concept study. BIOMEDICAL OPTICS EXPRESS 2022; 13:6470-6483. [PMID: 36589562 PMCID: PMC9774850 DOI: 10.1364/boe.474344] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/29/2022] [Revised: 11/03/2022] [Accepted: 11/06/2022] [Indexed: 06/17/2023]
Abstract
Glial tumors grow diffusely in the brain. Survival is correlated to the extent of tumor removal, but tumor borders are often invisible. Resection beyond the borders as defined by conventional methods may further improve prognosis. In this proof-of-concept study, we evaluate diffuse reflectance spectroscopy (DRS) for discrimination between glial tumors and normal brain ex vivo. DRS spectra and histology were acquired from 22 tumor samples and nine brain tissue samples retrieved from 30 patients. The content of biological chromophores and scattering features were estimated by fitting a model derived from diffusion theory to the DRS spectra. DRS parameters differed significantly between tumor and normal brain tissue. Classification using random forest yielded a sensitivity and specificity for the detection of low-grade gliomas of 82.0% and 82.7%, respectively, and the area under curve (AUC) was 0.91. Applied in a hand-held probe or biopsy needle, DRS has the potential to provide intra-operative tissue analysis.
Collapse
Affiliation(s)
- Simon Skyrman
- Department of Neurosurgery, Karolinska University Hospital, 171 64 Stockholm, Sweden
- Department of Clinical Neuroscience, Karolinska Institutet, 171 77 Stockholm, Sweden
| | - Gustav Burström
- Department of Neurosurgery, Karolinska University Hospital, 171 64 Stockholm, Sweden
- Department of Clinical Neuroscience, Karolinska Institutet, 171 77 Stockholm, Sweden
| | - Marco Lai
- Philips Research, 5656 AE, Eindhoven, The Netherlands
- Eindhoven University of Technology (TU/e), Eindhoven, The Netherlands
| | - Francesca Manni
- Eindhoven University of Technology (TU/e), Eindhoven, The Netherlands
| | - Benno Hendriks
- Philips Research, 5656 AE, Eindhoven, The Netherlands
- Department of Biomechanical Engineering, Delft University of Technology, 2628 CD, Delft, The Netherlands
| | - Arvid Frostell
- Department of Neurosurgery, Karolinska University Hospital, 171 64 Stockholm, Sweden
- Department of Clinical Neuroscience, Karolinska Institutet, 171 77 Stockholm, Sweden
| | - Erik Edström
- Department of Neurosurgery, Karolinska University Hospital, 171 64 Stockholm, Sweden
| | - Oscar Persson
- Department of Neurosurgery, Karolinska University Hospital, 171 64 Stockholm, Sweden
- Department of Clinical Neuroscience, Karolinska Institutet, 171 77 Stockholm, Sweden
| | - Adrian Elmi-Terander
- Department of Neurosurgery, Karolinska University Hospital, 171 64 Stockholm, Sweden
- Department of Clinical Neuroscience, Karolinska Institutet, 171 77 Stockholm, Sweden
- Stockholm Spine Center, 194 45 Upplands-Väsby, Sweden
| |
Collapse
|
5
|
Park MT, Abramov I, Gooldy TC, Smith KA, Porter RW, Little AS, Lawton MT, Eschbacher JM, Preul MC. Introduction of In Vivo Confocal Laser Endomicroscopy and Real-Time Telepathology for Remote Intraoperative Neurosurgery-Pathology Consultation. Oper Neurosurg (Hagerstown) 2022; 23:261-267. [PMID: 35972091 DOI: 10.1227/ons.0000000000000288] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2021] [Accepted: 03/22/2022] [Indexed: 02/04/2023] Open
Abstract
BACKGROUND Precise communication between neurosurgeons and pathologists is crucial for optimizing patient care, especially for intraoperative diagnoses. Confocal laser endomicroscopy (CLE) combined with a telepathology software platform (TSP) provides a novel venue for neurosurgeons and pathologists to review CLE images and converse intraoperatively in real-time. OBJECTIVE To describe the feasibility of integrating CLE and a TSP in the surgical workflow for real-time review of in vivo digital fluorescence tissue imaging in 3 patients with intracranial tumors. METHODS Although the neurosurgeon used the CLE probe to generate fluorescence images of histoarchitecture within the operative field that were displayed on monitors in the operating room, the pathologist simultaneously remotely viewed the CLE images. The neurosurgeon and pathologist discussed in real-time the histological structures of intraoperative imaging locations. RESULTS The neurosurgeon placed the CLE probe at various locations on and around the tumor, in the surgical resection bed, and on surrounding brain tissue with communication through the TSP. The neurosurgeon oriented the pathologist to the location of the CLE, and the pathologist and neurosurgeon discussed the CLE images in real-time. The TSP and CLE were integrated successfully and rapidly in the operating room in all 3 cases. No patient had perioperative complications. CONCLUSION Two novel digital neurosurgical cellular imaging technologies were combined with intraoperative neurosurgeon-pathologist communication to guide the identification of abnormal histoarchitectural tissue features in real-time. CLE with the TSP may allow rapid decision-making during tumor resection that may hold significant advantages over the frozen section process and surgical workflow in general.
Collapse
Affiliation(s)
- Marian T Park
- The Loyal and Edith Davis Neurosurgical Research Laboratory, Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona
| | - Irakliy Abramov
- The Loyal and Edith Davis Neurosurgical Research Laboratory, Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona
| | - Timothy C Gooldy
- The Loyal and Edith Davis Neurosurgical Research Laboratory, Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona
| | - Kris A Smith
- The Loyal and Edith Davis Neurosurgical Research Laboratory, Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona
| | - Randall W Porter
- The Loyal and Edith Davis Neurosurgical Research Laboratory, Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona
| | - Andrew S Little
- The Loyal and Edith Davis Neurosurgical Research Laboratory, Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona
| | - Michael T Lawton
- The Loyal and Edith Davis Neurosurgical Research Laboratory, Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona
| | - Jennifer M Eschbacher
- Department of Neuropathology, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona
| | - Mark C Preul
- The Loyal and Edith Davis Neurosurgical Research Laboratory, Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona
| |
Collapse
|
6
|
Miripour ZS, Abbasvandi F, Aghaee P, Shojaeian F, Faramarzpour M, Mohaghegh P, Hoseinpour P, Namdar N, Hassanpour Amiri M, Ghafari H, Parniani M, Kaviani A, Alamdar S, NajafiKhoshnoo S, Sanati H, Mapar M, Sadeghian N, Akbari ME, Yunesian M, Abdolahad M. Human study on cancer diagnostic probe (CDP) for real-time excising of breast positive cavity side margins based on tracing hypoxia glycolysis; checking diagnostic accuracy in non-neoadjuvant cases. Cancer Med 2022; 11:1630-1645. [PMID: 35224879 PMCID: PMC8986141 DOI: 10.1002/cam4.4503] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2021] [Revised: 10/25/2021] [Accepted: 11/18/2021] [Indexed: 01/05/2023] Open
Abstract
BACKGROUND Cancer diagnostic probe (CDP) had been developed to detect involved breast cavity side margins in real-time (Miripour et al. Bioeng Transl Med. e10236.). Here, we presented the results of the in vivo human model CDP studies on non-neoadjuvant cases. METHODS This study is a prospective, blind comparison to a gold standard, and the medical group recruited patients. CDP and frozen data were achieved before the permanent pathology experiment. The main outcome of the study is surgical margin status. From November 2018 to April 2020, 202 patients were registered, and 188 were assigned for the study. Breast-conserving surgery at any age or gender, re-surgery due to re-currency, or involved margins are acceptable. Patients must be non-neoadjuvant. The reliability of CDP scoring had been evaluated by the pathology of the scored IMs. Then, three models of the study were designed to compare CDP with the frozen sections. Receiver operating characteristic (ROC) curves and AUC were measured based on the permanent postoperative pathology gold standard. RESULTS A matched clinical diagnostic categorization between the pathological results of the tested IMs and response peaks of CDP on 113 cases, was reported (sensitivity = 97%, specificity = 89.3%, accuracy = 92%, positive predictive value (PPV) = 84.2%, and negative predictive value (NPV) = 98%). Study A showed the independent ability of CDP for IM scoring (sensitivity = 80%, specificity = 90%, accuracy = 90%, PPV = 22.2%, and NPV = 99.2%). Study B showed the complementary role of CDP to cover the missed lesions of frozen sections (sensitivity = 93.8%, specificity = 91%, accuracy = 91%, PPV = 55.6%, and NPV = 99.2%). Study C showed the ability of CDP in helping the pathologist to reduce his/her frozen miss judgment (specificity = 92%, accuracy = 93%, PPV = 42.1%, and NPV = 100%). Results were reported based on the post-surgical permanent pathology gold standard. CONCLUSION CDP scoring ability in intra-operative margin detection was verified on non-neoadjuvant breast cancer patients. Non-invasive real-time diagnosis of IMs with pathological values may make CDP a distinct tool with handheld equipment to increase the prognosis of breast cancer patients.
Collapse
Affiliation(s)
- Zohreh Sadat Miripour
- Nano Bio Electronic Devices LabSchool of Electrical and Computer EngineeringCollege of EngineeringUniversity of TehranTehranIran
- Nano Electronic Center of ExcellenceThin Film and Nanoelectronics LabSchool of Electrical and Computer EngineeringCollege of EngineeringUniversity of TehranTehranIran
| | - Fereshteh Abbasvandi
- Nano Bio Electronic Devices LabSchool of Electrical and Computer EngineeringCollege of EngineeringUniversity of TehranTehranIran
- ATMP DepartmentBreast Cancer Research CenterMotamed Cancer InstituteACECRTehranIran
- Cancer Research CenterShahid Beheshti University of Medical SciencesTehranIran
| | - Parisa Aghaee
- Nano Bio Electronic Devices LabSchool of Electrical and Computer EngineeringCollege of EngineeringUniversity of TehranTehranIran
- Nano Electronic Center of ExcellenceThin Film and Nanoelectronics LabSchool of Electrical and Computer EngineeringCollege of EngineeringUniversity of TehranTehranIran
| | - Fatemeh Shojaeian
- Cancer Research CenterShahid Beheshti University of Medical SciencesTehranIran
| | - Mahsa Faramarzpour
- Nano Bio Electronic Devices LabSchool of Electrical and Computer EngineeringCollege of EngineeringUniversity of TehranTehranIran
- Nano Electronic Center of ExcellenceThin Film and Nanoelectronics LabSchool of Electrical and Computer EngineeringCollege of EngineeringUniversity of TehranTehranIran
| | - Pooneh Mohaghegh
- Nano Bio Electronic Devices LabSchool of Electrical and Computer EngineeringCollege of EngineeringUniversity of TehranTehranIran
- Nano Electronic Center of ExcellenceThin Film and Nanoelectronics LabSchool of Electrical and Computer EngineeringCollege of EngineeringUniversity of TehranTehranIran
| | | | - Naser Namdar
- Nano Bio Electronic Devices LabSchool of Electrical and Computer EngineeringCollege of EngineeringUniversity of TehranTehranIran
- Nano Electronic Center of ExcellenceThin Film and Nanoelectronics LabSchool of Electrical and Computer EngineeringCollege of EngineeringUniversity of TehranTehranIran
| | - Morteza Hassanpour Amiri
- Nano Bio Electronic Devices LabSchool of Electrical and Computer EngineeringCollege of EngineeringUniversity of TehranTehranIran
- Nano Electronic Center of ExcellenceThin Film and Nanoelectronics LabSchool of Electrical and Computer EngineeringCollege of EngineeringUniversity of TehranTehranIran
| | - Hadi Ghafari
- Nano Bio Electronic Devices LabSchool of Electrical and Computer EngineeringCollege of EngineeringUniversity of TehranTehranIran
| | - Mohammad Parniani
- Pathology DepartmentBreast Cancer Research CenterMotamed Cancer InstituteACECRTehranIran
| | - Ahmad Kaviani
- Institute of CancerImam Khomeini HospitalTehran University of Medical SciencesTehranIran
| | - Sedigheh Alamdar
- Department of PathobiologyIran University of Medical SciencesShahid Hemmat HighwayTehranIran
| | - Sahar NajafiKhoshnoo
- Nano Bio Electronic Devices LabSchool of Electrical and Computer EngineeringCollege of EngineeringUniversity of TehranTehranIran
| | - Hassan Sanati
- ATMP DepartmentBreast Cancer Research CenterMotamed Cancer InstituteACECRTehranIran
| | - Mahna Mapar
- Nano Bio Electronic Devices LabSchool of Electrical and Computer EngineeringCollege of EngineeringUniversity of TehranTehranIran
| | - Nastaran Sadeghian
- ATMP DepartmentBreast Cancer Research CenterMotamed Cancer InstituteACECRTehranIran
| | | | - Masud Yunesian
- Department of Environmental HealthSchool of Public HealthTehran University of Medical SciencesTehranIran
- Department of Research Methodology and Data AnalysisInstitute for Environmental ResearchTehran University of Medical SciencesTehranIran
| | - Mohammad Abdolahad
- Nano Bio Electronic Devices LabSchool of Electrical and Computer EngineeringCollege of EngineeringUniversity of TehranTehranIran
- Nano Electronic Center of ExcellenceThin Film and Nanoelectronics LabSchool of Electrical and Computer EngineeringCollege of EngineeringUniversity of TehranTehranIran
- Institute of CancerImam Khomeini HospitalTehran University of Medical SciencesTehranIran
- UT&TUMS Cancer Electronics Research CenterTehran University of Medical SciencesTehranIran
| |
Collapse
|
7
|
Miripour ZS, Abbasvandi F, Aghaee P, NajafiKhoshnoo S, Faramarzpour M, Mohaghegh P, Hoseinpour P, Namdar N, Amiri MH, Ghafari H, Zareie S, Shojaeian F, Sanati H, Mapar M, Sadeghian N, Akbari ME, Khayamian MA, Abdolahad M. Electrochemical tracing of hypoxia glycolysis by carbon nanotube sensors, a new hallmark for intraoperative detection of suspicious margins to breast neoplasia. Bioeng Transl Med 2022; 7:e10236. [PMID: 35079624 PMCID: PMC8780057 DOI: 10.1002/btm2.10236] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2021] [Accepted: 05/18/2021] [Indexed: 12/03/2022] Open
Abstract
For most people, the first step in treatment is to take out the tumor (surgery), so precise and fast diagnosis of any sign of high-risk and neoplastic cells, especially in surgical cavity margins, is significant. The frozen pathology method is the conventional standard of intraoperative diagnosis, but the low number of slides prepared from non-fixed tissues prevents us from achieving a perfect diagnosis. Although many improvements in intraoperative margin detection were achieved, still real-time detection of neoplastic lesions is crucial to improving diagnostic quality. Functionalized carbon nanotubes grown on the electrode needles lively and selectively determine the H2O2 released from cancer/atypical cells through reverse Warburg effect and hypoxia assisted glycolysis pathways in a quantitative electrochemical manner. The study was carried out on cell lines, 57 in vivo mice models with breast cancer, and 258 fresh in vitro samples of breast cancer tumors. A real-time electrotechnical system, named cancer diagnostic probe (CDP) (US Patent Pub. No.: US 2018/02991 A1, US 2021/0007638 A1, and US 2021/0022650 A1 [publications], and US 10,786,188 B1 [granted]), has been developed to find pre-neoplastic/neoplastic cells in vivo in a quantitative electrochemical manner by tracing hypoxia glycolysis byproducts. Matched pathological evaluations with response peaks of CDP were found based on the presence of neoplasia (from atypia to invasive carcinoma) in live breast tissues. The ability of CDP to find neoplastic lesions in mice models in vivo and fresh breast tumors in vitro was verified with sensitivity and specificity of 95% and 97%, respectively. The system may help a surgeon assistant system for usage in the operating room after passing many trials and standard examinations in the future.
Collapse
Affiliation(s)
- Zohreh Sadat Miripour
- Nano Bio Electronic Devices Lab, School of Electrical and Computer Engineering, College of EngineeringUniversity of TehranTehranIran
- Nano Electronic Center of Excellence, Thin Film and Nanoelectronics Lab, School of Electrical and Computer Engineering, College of EngineeringUniversity of TehranTehranIran
| | - Fereshteh Abbasvandi
- ATMP DepartmentBreast Cancer Research Center, Motamed Cancer Institute, ACECRTehranIran
| | - Parisa Aghaee
- Nano Bio Electronic Devices Lab, School of Electrical and Computer Engineering, College of EngineeringUniversity of TehranTehranIran
- Nano Electronic Center of Excellence, Thin Film and Nanoelectronics Lab, School of Electrical and Computer Engineering, College of EngineeringUniversity of TehranTehranIran
| | - Sahar NajafiKhoshnoo
- Nano Bio Electronic Devices Lab, School of Electrical and Computer Engineering, College of EngineeringUniversity of TehranTehranIran
| | - Mahsa Faramarzpour
- Nano Bio Electronic Devices Lab, School of Electrical and Computer Engineering, College of EngineeringUniversity of TehranTehranIran
- Nano Electronic Center of Excellence, Thin Film and Nanoelectronics Lab, School of Electrical and Computer Engineering, College of EngineeringUniversity of TehranTehranIran
| | - Pooneh Mohaghegh
- Nano Bio Electronic Devices Lab, School of Electrical and Computer Engineering, College of EngineeringUniversity of TehranTehranIran
- Nano Electronic Center of Excellence, Thin Film and Nanoelectronics Lab, School of Electrical and Computer Engineering, College of EngineeringUniversity of TehranTehranIran
| | | | - Naser Namdar
- Nano Bio Electronic Devices Lab, School of Electrical and Computer Engineering, College of EngineeringUniversity of TehranTehranIran
- Nano Electronic Center of Excellence, Thin Film and Nanoelectronics Lab, School of Electrical and Computer Engineering, College of EngineeringUniversity of TehranTehranIran
| | - Morteza Hassanpour Amiri
- Nano Bio Electronic Devices Lab, School of Electrical and Computer Engineering, College of EngineeringUniversity of TehranTehranIran
- Nano Electronic Center of Excellence, Thin Film and Nanoelectronics Lab, School of Electrical and Computer Engineering, College of EngineeringUniversity of TehranTehranIran
| | - Hadi Ghafari
- Nano Bio Electronic Devices Lab, School of Electrical and Computer Engineering, College of EngineeringUniversity of TehranTehranIran
| | - Sarah Zareie
- Nano Bio Electronic Devices Lab, School of Electrical and Computer Engineering, College of EngineeringUniversity of TehranTehranIran
- Nano Electronic Center of Excellence, Thin Film and Nanoelectronics Lab, School of Electrical and Computer Engineering, College of EngineeringUniversity of TehranTehranIran
| | - Fatemeh Shojaeian
- Cancer Research CenterShahid Beheshti University of Medical SciencesTehranIran
| | - Hassan Sanati
- Integrative Oncology DepartmentBreast Cancer Research Center, Motamed Cancer Institute, ACECRTehranIran
| | - Mahna Mapar
- Nano Bio Electronic Devices Lab, School of Electrical and Computer Engineering, College of EngineeringUniversity of TehranTehranIran
| | - Nastaran Sadeghian
- ATMP DepartmentBreast Cancer Research Center, Motamed Cancer Institute, ACECRTehranIran
| | | | - Mohammad Ali Khayamian
- Nano Bio Electronic Devices Lab, School of Electrical and Computer Engineering, College of EngineeringUniversity of TehranTehranIran
- Nano Electronic Center of Excellence, Thin Film and Nanoelectronics Lab, School of Electrical and Computer Engineering, College of EngineeringUniversity of TehranTehranIran
| | - Mohammad Abdolahad
- Nano Bio Electronic Devices Lab, School of Electrical and Computer Engineering, College of EngineeringUniversity of TehranTehranIran
- Nano Electronic Center of Excellence, Thin Film and Nanoelectronics Lab, School of Electrical and Computer Engineering, College of EngineeringUniversity of TehranTehranIran
- Cancer Institute, Imam Khomeini HospitalTehran University of Medical SciencesTehranIran
- UT&TUMS Cancer Electrotechnique Research CenterYAS Hospital, Tehran University of Medical SciencesTehranIran
| |
Collapse
|
8
|
Socio-Organizational Impact of Confocal Laser Endomicroscopy in Neurosurgery and Neuropathology: Results from a Process Analysis and Expert Survey. Diagnostics (Basel) 2021; 11:diagnostics11112128. [PMID: 34829475 PMCID: PMC8623423 DOI: 10.3390/diagnostics11112128] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2021] [Revised: 11/04/2021] [Accepted: 11/09/2021] [Indexed: 11/16/2022] Open
Abstract
During brain tumor resection surgery, it is essential to determine the tumor borders as the extent of resection is important for post-operative patient survival. The current process of removing a tissue sample for frozen section analysis has several shortcomings that might be overcome by confocal laser endomicroscopy (CLE). CLE is a promising new technology enabling the digital in vivo visualization of tissue structures in near real-time. Research on the socio-organizational impact of introducing this new methodology to routine care in neurosurgery and neuropathology is scarce. We analyzed a potential clinical workflow employing CLE by comparing it to the current process. Additionally, a small expert survey was conducted to collect data on the opinion of clinical staff working with CLE. While CLE can contribute to a workload reduction for neuropathologists and enable a shorter process and a more efficient use of resources, the effort for neurosurgeons and surgery assistants might increase. Experts agree that CLE offers huge potential for better diagnosis and therapy but also see challenges, especially due to the current state of experimental use, including a risk for misinterpretations and the need for special training. Future studies will show whether CLE can become part of routine care.
Collapse
|
9
|
Abramov I, Dru AB, Belykh E, Park MT, Bardonova L, Preul MC. Redosing of Fluorescein Sodium Improves Image Interpretation During Intraoperative Ex Vivo Confocal Laser Endomicroscopy of Brain Tumors. Front Oncol 2021; 11:668661. [PMID: 34660258 PMCID: PMC8514872 DOI: 10.3389/fonc.2021.668661] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2021] [Accepted: 09/13/2021] [Indexed: 12/15/2022] Open
Abstract
Background Fluorescein sodium (FNa) is a fluorescence agent used with a wide-field operating microscope for intraoperative guidance and with confocal laser endomicroscopy (CLE) to evaluate brain tissue. Susceptibility of FNa to degradation over time may affect CLE image quality during prolonged surgeries. This study describes improved characteristics of CLE images after intraoperative redosing with FNa. Methods A retrospective analysis was performed using CLE images obtained ex vivo from samples obtained during tumor resections with FNa-based fluorescence guidance with a wide-field operating microscope. The comparison groups included CLE images acquired after FNa redosing (redose imaging group), images from the same patients acquired after the initial FNa dose (initial-dose imaging group), and images from patients in whom redosing was not used (single-dose imaging group). A detailed assessment of image quality and interpretation regarding different FNa dosage and timing of imaging after FNa administration was conducted for all comparison groups. Results The brightest and most contrasting images were observed in the redose group compared to the initial-dose and single-dose groups (P<0.001). The decay of FNa signal negatively correlated with brightness (rho = -0.52, P<0.001) and contrast (rho = -0.57, P<0.001). Different doses of FNa did not significantly affect the brightness (P=0.15) or contrast (P=0.09) in CLE images. As the mean timing of imaging increased, the percentage of accurately diagnosed images decreased (P=0.03). Conclusions The decay of the FNa signal is directly associated with image brightness and contrast. The qualitative interpretation scores of images were highest for the FNa redose imaging group. Redosing with FNa to improve the utility of CLE imaging should be considered a safe and beneficial strategy during prolonged surgeries.
Collapse
Affiliation(s)
- Irakliy Abramov
- The Loyal and Edith Davis Neurosurgical Research Laboratory, Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, AZ, United States
| | - Alexander B Dru
- The Loyal and Edith Davis Neurosurgical Research Laboratory, Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, AZ, United States
| | - Evgenii Belykh
- Department of Neurosurgery, Rutgers New Jersey Medical School, Newark, NJ, United States
| | - Marian T Park
- The Loyal and Edith Davis Neurosurgical Research Laboratory, Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, AZ, United States
| | - Liudmila Bardonova
- The Loyal and Edith Davis Neurosurgical Research Laboratory, Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, AZ, United States
| | - Mark C Preul
- The Loyal and Edith Davis Neurosurgical Research Laboratory, Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, AZ, United States
| |
Collapse
|
10
|
Ziebart A, Stadniczuk D, Roos V, Ratliff M, von Deimling A, Hänggi D, Enders F. Deep Neural Network for Differentiation of Brain Tumor Tissue Displayed by Confocal Laser Endomicroscopy. Front Oncol 2021; 11:668273. [PMID: 34046358 PMCID: PMC8147727 DOI: 10.3389/fonc.2021.668273] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2021] [Accepted: 04/09/2021] [Indexed: 01/31/2023] Open
Abstract
Background Reliable on site classification of resected tumor specimens remains a challenge. Implementation of high-resolution confocal laser endoscopic techniques (CLEs) during fluorescence-guided brain tumor surgery is a new tool for intraoperative tumor tissue visualization. To overcome observer dependent errors, we aimed to predict tumor type by applying a deep learning model to image data obtained by CLE. Methods Human brain tumor specimens from 25 patients with brain metastasis, glioblastoma, and meningioma were evaluated within this study. In addition to routine histopathological analysis, tissue samples were stained with fluorescein ex vivo and analyzed with CLE. We trained two convolutional neural networks and built a predictive level for the outputs. Results Multiple CLE images were obtained from each specimen with a total number of 13,972 fluorescein based images. Test accuracy of 90.9% was achieved after applying a two-class prediction for glioblastomas and brain metastases with an area under the curve (AUC) value of 0.92. For three class predictions, our model achieved a ratio of correct predicted label of 85.8% in the test set, which was confirmed with five-fold cross validation, without definition of confidence. Applying a confidence rate of 0.999 increased the prediction accuracy to 98.6% when images with substantial artifacts were excluded before the analysis. 36.3% of total images met the output criteria. Conclusions We trained a residual network model that allows automated, on site analysis of resected tumor specimens based on CLE image datasets. Further in vivo studies are required to assess the clinical benefit CLE can have.
Collapse
Affiliation(s)
- Andreas Ziebart
- Department of Neurosurgery, University Hospital Mannheim, Medical Faculty Mannheim, University of Heidelberg, Mannheim, Germany
| | - Denis Stadniczuk
- Department of Software Engineering, Clevertech Inc., New York, NY, United States
| | - Veronika Roos
- Department of Neurosurgery, University Hospital Mannheim, Medical Faculty Mannheim, University of Heidelberg, Mannheim, Germany
| | - Miriam Ratliff
- Department of Neurosurgery, University Hospital Mannheim, Medical Faculty Mannheim, University of Heidelberg, Mannheim, Germany
| | - Andreas von Deimling
- Department of Neuropathology, University Hospital Heidelberg, and CCU Neuropathology, DKFZ, Heidelberg, Germany
| | - Daniel Hänggi
- Department of Neurosurgery, University Hospital Mannheim, Medical Faculty Mannheim, University of Heidelberg, Mannheim, Germany.,Department of Neurosurgery, Medical Faculty, Heinrich-Heine-University Düsseldorf, Düsseldorf, Germany
| | - Frederik Enders
- Department of Neurosurgery, University Hospital Mannheim, Medical Faculty Mannheim, University of Heidelberg, Mannheim, Germany
| |
Collapse
|
11
|
Restelli F, Pollo B, Vetrano IG, Cabras S, Broggi M, Schiariti M, Falco J, de Laurentis C, Raccuia G, Ferroli P, Acerbi F. Confocal Laser Microscopy in Neurosurgery: State of the Art of Actual Clinical Applications. J Clin Med 2021; 10:jcm10092035. [PMID: 34068592 PMCID: PMC8126060 DOI: 10.3390/jcm10092035] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2021] [Revised: 05/01/2021] [Accepted: 05/04/2021] [Indexed: 12/11/2022] Open
Abstract
Achievement of complete resections is of utmost importance in brain tumor surgery, due to the established correlation among extent of resection and postoperative survival. Various tools have recently been included in current clinical practice aiming to more complete resections, such as neuronavigation and fluorescent-aided techniques, histopathological analysis still remains the gold-standard for diagnosis, with frozen section as the most used, rapid and precise intraoperative histopathological method that permits an intraoperative differential diagnosis. Unfortunately, due to the various limitations linked to this technique, it is still unsatisfactorily for obtaining real-time intraoperative diagnosis. Confocal laser technology has been recently suggested as a promising method to obtain near real-time intraoperative histological data in neurosurgery, due to its established use in other non-neurosurgical fields. Still far to be widely implemented in current neurosurgical clinical practice, this technology was initially studied in preclinical experiences confirming its utility in identifying brain tumors, microvasculature and tumor margins. Hence, ex vivo and in vivo clinical studies evaluated the possibility with this technology of identifying and classifying brain neoplasms, discerning between normal and pathologic tissue, showing very promising results. This systematic review has the main objective of presenting a state-of-the-art summary on actual clinical applications of confocal laser imaging in neurosurgical practice.
Collapse
Affiliation(s)
- Francesco Restelli
- Department of Neurosurgery, Fondazione IRCCS Istituto Neurologico Carlo Besta, 20133 Milan, Italy; (F.R.); (I.G.V.); (S.C.); (M.B.); (M.S.); (J.F.); (C.d.L.); (G.R.); (P.F.)
| | - Bianca Pollo
- Neuropathology Unit, Fondazione IRCCS Istituto Neurologico Carlo Besta, 20133 Milan, Italy;
| | - Ignazio Gaspare Vetrano
- Department of Neurosurgery, Fondazione IRCCS Istituto Neurologico Carlo Besta, 20133 Milan, Italy; (F.R.); (I.G.V.); (S.C.); (M.B.); (M.S.); (J.F.); (C.d.L.); (G.R.); (P.F.)
| | - Samuele Cabras
- Department of Neurosurgery, Fondazione IRCCS Istituto Neurologico Carlo Besta, 20133 Milan, Italy; (F.R.); (I.G.V.); (S.C.); (M.B.); (M.S.); (J.F.); (C.d.L.); (G.R.); (P.F.)
| | - Morgan Broggi
- Department of Neurosurgery, Fondazione IRCCS Istituto Neurologico Carlo Besta, 20133 Milan, Italy; (F.R.); (I.G.V.); (S.C.); (M.B.); (M.S.); (J.F.); (C.d.L.); (G.R.); (P.F.)
| | - Marco Schiariti
- Department of Neurosurgery, Fondazione IRCCS Istituto Neurologico Carlo Besta, 20133 Milan, Italy; (F.R.); (I.G.V.); (S.C.); (M.B.); (M.S.); (J.F.); (C.d.L.); (G.R.); (P.F.)
| | - Jacopo Falco
- Department of Neurosurgery, Fondazione IRCCS Istituto Neurologico Carlo Besta, 20133 Milan, Italy; (F.R.); (I.G.V.); (S.C.); (M.B.); (M.S.); (J.F.); (C.d.L.); (G.R.); (P.F.)
| | - Camilla de Laurentis
- Department of Neurosurgery, Fondazione IRCCS Istituto Neurologico Carlo Besta, 20133 Milan, Italy; (F.R.); (I.G.V.); (S.C.); (M.B.); (M.S.); (J.F.); (C.d.L.); (G.R.); (P.F.)
| | - Gabriella Raccuia
- Department of Neurosurgery, Fondazione IRCCS Istituto Neurologico Carlo Besta, 20133 Milan, Italy; (F.R.); (I.G.V.); (S.C.); (M.B.); (M.S.); (J.F.); (C.d.L.); (G.R.); (P.F.)
| | - Paolo Ferroli
- Department of Neurosurgery, Fondazione IRCCS Istituto Neurologico Carlo Besta, 20133 Milan, Italy; (F.R.); (I.G.V.); (S.C.); (M.B.); (M.S.); (J.F.); (C.d.L.); (G.R.); (P.F.)
| | - Francesco Acerbi
- Department of Neurosurgery, Fondazione IRCCS Istituto Neurologico Carlo Besta, 20133 Milan, Italy; (F.R.); (I.G.V.); (S.C.); (M.B.); (M.S.); (J.F.); (C.d.L.); (G.R.); (P.F.)
- Correspondence: ; Tel.: +39-022-3932-309
| |
Collapse
|
12
|
Soliton microcomb based spectral domain optical coherence tomography. Nat Commun 2021; 12:427. [PMID: 33462200 PMCID: PMC7813855 DOI: 10.1038/s41467-020-20404-9] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2020] [Accepted: 11/05/2020] [Indexed: 12/22/2022] Open
Abstract
Spectral domain optical coherence tomography (OCT) is a widely employed, minimally invasive bio-medical imaging technique, which requires a broadband light source, typically implemented by super-luminescent diodes. Recent advances in soliton based photonic integrated frequency combs (soliton microcombs) have enabled the development of low-noise, broadband chipscale frequency comb sources, whose potential for OCT imaging has not yet been unexplored. Here, we explore the use of dissipative Kerr soliton microcombs in spectral domain OCT and show that, by using photonic chipscale Si3N4 resonators in conjunction with 1300 nm pump lasers, spectral bandwidths exceeding those of commercial OCT sources are possible. We characterized the exceptional noise properties of our source (in comparison to conventional OCT sources) and demonstrate that the soliton states in microresonators exhibit a residual intensity noise floor at high offset frequencies that is ca. 3 dB lower than a traditional OCT source at identical power, and can exhibit significantly lower noise performance for powers at the milli-Watt level. Moreover, we demonstrate that classical amplitude noise of all soliton comb teeth are correlated, i.e., common mode, in contrast to superluminescent diodes or incoherent microcomb states, which opens a new avenue to improve imaging speed and performance beyond the thermal noise limit. Superluminescent diodes, that provide a broadband spectrum are typically used in spectral domain coherence tomography. Here, the authors use chipscale silicon nitride resonators to generate soliton microcombs with a lower noise flor that could substitute the diode sources.
Collapse
|
13
|
Acerbi F, Pollo B, De Laurentis C, Restelli F, Falco J, Vetrano IG, Broggi M, Schiariti M, Tramacere I, Ferroli P, DiMeco F. Ex Vivo Fluorescein-Assisted Confocal Laser Endomicroscopy (CONVIVO® System) in Patients With Glioblastoma: Results From a Prospective Study. Front Oncol 2020; 10:606574. [PMID: 33425764 PMCID: PMC7787149 DOI: 10.3389/fonc.2020.606574] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2020] [Accepted: 11/19/2020] [Indexed: 01/02/2023] Open
Abstract
Background Confocal laser endomicroscopy (CLE) allowing intraoperative near real-time high-resolution cellular visualization is a promising method in neurosurgery. We prospectively tested the accuracy of a new-designed miniatured CLE (CONVIVO® system) in giving an intraoperative first-diagnosis during glioblastoma removal. Methods Between January and May 2018, 15 patients with newly diagnosed glioblastoma underwent fluorescein-guided surgery. Two biopsies from both tumor central core and margins were harvested, dividing each sample into two specimens. Biopsies were firstly intraoperatively ex vivo analyzed by CLE, subsequently processed for frozen and permanent fixation, respectively. Then, a blind comparison was conducted between CLE and standard permanent section analyses, checking for CLE ability to provide diagnosis and categorize morphological patterns intraoperatively. Results Blindly comparing CONVIVO® and frozen sections images we obtained a high rate of concordance in both providing a correct diagnosis and categorizing patterns at tumor central core (80 and 93.3%, respectively) and at tumor margins (80% for both objectives). Comparing CONVIVO® and permanent sections, concordance resulted similar at central core (total/partial concordance in 80 and 86.7% for diagnosis and morphological categorization, respectively) and lower at tumor margins (66.6% for both categories). Time from fluorescein injection and time from biopsy sampling to CONVIVO® scanning was 134 ± 31 min (122–214 min) and 9.23 min (1–17min), respectively. Mean time needed for CONVIVO® images interpretation was 5.74 min (1–7 min). Conclusions The high rate of diagnostic/morphological consistency found between CONVIVO® and frozen section analyses suggests the possibility to use CLE as a complementary tool for intraoperative diagnosis of ex vivo tissue specimens during glioblastoma surgery.
Collapse
Affiliation(s)
- Francesco Acerbi
- Department of Neurosurgery, Fondazione IRCCS Istituto Neurologico Carlo Besta, Milan, Italy
| | - Bianca Pollo
- Neuropathology Unit, Fondazione IRCCS Istituto Neurologico Carlo Besta, Milan, Italy
| | - Camilla De Laurentis
- Department of Neurosurgery, Fondazione IRCCS Istituto Neurologico Carlo Besta, Milan, Italy
| | - Francesco Restelli
- Department of Neurosurgery, Fondazione IRCCS Istituto Neurologico Carlo Besta, Milan, Italy
| | - Jacopo Falco
- Department of Neurosurgery, Fondazione IRCCS Istituto Neurologico Carlo Besta, Milan, Italy
| | - Ignazio G Vetrano
- Department of Neurosurgery, Fondazione IRCCS Istituto Neurologico Carlo Besta, Milan, Italy
| | - Morgan Broggi
- Department of Neurosurgery, Fondazione IRCCS Istituto Neurologico Carlo Besta, Milan, Italy
| | - Marco Schiariti
- Department of Neurosurgery, Fondazione IRCCS Istituto Neurologico Carlo Besta, Milan, Italy
| | - Irene Tramacere
- Department of Research and Clinical Development, Scientific Directorate, Fondazione IRCCS Istituto Neurologico Carlo Besta, Milan, Italy
| | - Paolo Ferroli
- Department of Neurosurgery, Fondazione IRCCS Istituto Neurologico Carlo Besta, Milan, Italy
| | - Francesco DiMeco
- Department of Neurosurgery, Fondazione IRCCS Istituto Neurologico Carlo Besta, Milan, Italy.,Department of Pathophysiology and Transplantation, University of Milano, Milan, Italy
| |
Collapse
|
14
|
Belykh E, Zhao X, Ngo B, Farhadi DS, Byvaltsev VA, Eschbacher JM, Nakaji P, Preul MC. Intraoperative Confocal Laser Endomicroscopy Ex Vivo Examination of Tissue Microstructure During Fluorescence-Guided Brain Tumor Surgery. Front Oncol 2020; 10:599250. [PMID: 33344251 PMCID: PMC7746822 DOI: 10.3389/fonc.2020.599250] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2020] [Accepted: 10/26/2020] [Indexed: 12/20/2022] Open
Abstract
Background Noninvasive intraoperative optical biopsy that provides real-time imaging of histoarchitectural (cell resolution) features of brain tumors, especially at the margin of invasive tumors, would be of great value. To assess clinical-grade confocal laser endomicroscopy (CLE) and to prepare for its use intraoperatively in vivo, we performed an assessment of CLE ex vivo imaging in brain lesions. Methods Tissue samples from patients who underwent intracranial surgeries with fluorescein sodium (FNa)–based wide-field fluorescence guidance were acquired for immediate intraoperative ex vivo optical biopsies with CLE. Hematoxylin-eosin–stained frozen section analysis of the same specimens served as the gold standard for blinded neuropathology comparison. FNa 2 to 5 mg/kg was administered upon induction of anesthesia, and FNa 5 mg/kg was injected for CLE contrast improvement. Histologic features were identified, and the diagnostic accuracy of CLE was assessed. Results Of 77 eligible patients, 47 patients with 122 biopsies were enrolled, including 32 patients with gliomas and 15 patients with other intracranial lesions. The positive predictive value of CLE optical biopsies was 97% for all specimens and 98% for gliomas. The specificity of CLE was 90% for all specimens and 94% for gliomas. The second FNa injection in seven patients, a mean of 2.6 h after the first injection, improved image quality and increased the percentage of accurately diagnosed images from 67% to 93%. Diagnostic CLE features of lesional glioma biopsies and normal brain were identified. Seventeen histologic features were identified. Conclusions Results demonstrated high specificity and positive predictive value of ex vivo intraoperative CLE optical biopsies and justify an in vivo intraoperative trial. This new portable, noninvasive intraoperative imaging technique provides diagnostic features to discriminate lesional tissue with high specificity and is feasible for incorporation into the fluorescence-guided surgery workflow, particularly for patients with invasive brain tumors.
Collapse
Affiliation(s)
- Evgenii Belykh
- Department of Neurosurgery, The Loyal and Edith Davis Neurosurgical Research Laboratory, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, AZ, United States
| | - Xiaochun Zhao
- Department of Neurosurgery, The Loyal and Edith Davis Neurosurgical Research Laboratory, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, AZ, United States
| | - Brandon Ngo
- Department of Neurosurgery, The Loyal and Edith Davis Neurosurgical Research Laboratory, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, AZ, United States
| | - Dara S Farhadi
- Department of Neurosurgery, The Loyal and Edith Davis Neurosurgical Research Laboratory, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, AZ, United States
| | - Vadim A Byvaltsev
- Department of Neurosurgery and Innovative Medicine, Irkutsk State Medical University, Irkutsk, Russia
| | - Jennifer M Eschbacher
- Department of Neuropathology, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, AZ, United States
| | - Peter Nakaji
- Department of Neurosurgery, The Loyal and Edith Davis Neurosurgical Research Laboratory, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, AZ, United States
| | - Mark C Preul
- Department of Neurosurgery, The Loyal and Edith Davis Neurosurgical Research Laboratory, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, AZ, United States
| |
Collapse
|
15
|
Belykh E, Ngo B, Farhadi DS, Zhao X, Mooney MA, White WL, Daniels JK, Little AS, Eschbacher JM, Preul MC. Confocal Laser Endomicroscopy Assessment of Pituitary Tumor Microstructure: A Feasibility Study. J Clin Med 2020; 9:jcm9103146. [PMID: 33003336 PMCID: PMC7600847 DOI: 10.3390/jcm9103146] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2020] [Revised: 09/12/2020] [Accepted: 09/23/2020] [Indexed: 12/12/2022] Open
Abstract
This is the first study to assess confocal laser endomicroscopy (CLE) use within the transsphenoidal approach and show the feasibility of obtaining digital diagnostic biopsies of pituitary tumor tissue after intravenous fluorescein injection. We confirmed that the CLE probe reaches the tuberculum sellae through the transnasal transsphenoidal corridor in cadaveric heads. Next, we confirmed that CLE provides images with identifiable histological features of pituitary adenoma. Biopsies from nine patients who underwent pituitary adenoma surgery were imaged ex vivo at various times after fluorescein injection and were assessed by a blinded board-certified neuropathologist. With frozen sections used as the standard, pituitary adenoma was diagnosed as “definitively” for 13 and as “favoring” in 3 of 16 specimens. CLE digital biopsies were diagnostic for pituitary adenoma in 10 of 16 specimens. The reasons for nondiagnostic CLE images were biopsy acquisition <1 min or >10 min after fluorescein injection (n = 5) and blood artifacts (n = 1). In conclusion, fluorescein provided sufficient contrast for CLE at a dose of 2 mg/kg, optimally 1–10 min after injection. These results provide a basis for further in vivo studies using CLE in transsphenoidal surgery.
Collapse
Affiliation(s)
- Evgenii Belykh
- The Loyal and Edith Davis Neurosurgical Research Laboratory, Department of Neurosurgery, Barrow Neurological Institute, St. Joseph’s Hospital and Medical Center, Phoenix, AZ 85013, USA; (E.B.); (B.N.); (D.S.F.); (X.Z.); (M.A.M.); (W.L.W.); (A.S.L.)
| | - Brandon Ngo
- The Loyal and Edith Davis Neurosurgical Research Laboratory, Department of Neurosurgery, Barrow Neurological Institute, St. Joseph’s Hospital and Medical Center, Phoenix, AZ 85013, USA; (E.B.); (B.N.); (D.S.F.); (X.Z.); (M.A.M.); (W.L.W.); (A.S.L.)
| | - Dara S. Farhadi
- The Loyal and Edith Davis Neurosurgical Research Laboratory, Department of Neurosurgery, Barrow Neurological Institute, St. Joseph’s Hospital and Medical Center, Phoenix, AZ 85013, USA; (E.B.); (B.N.); (D.S.F.); (X.Z.); (M.A.M.); (W.L.W.); (A.S.L.)
| | - Xiaochun Zhao
- The Loyal and Edith Davis Neurosurgical Research Laboratory, Department of Neurosurgery, Barrow Neurological Institute, St. Joseph’s Hospital and Medical Center, Phoenix, AZ 85013, USA; (E.B.); (B.N.); (D.S.F.); (X.Z.); (M.A.M.); (W.L.W.); (A.S.L.)
| | - Michael A. Mooney
- The Loyal and Edith Davis Neurosurgical Research Laboratory, Department of Neurosurgery, Barrow Neurological Institute, St. Joseph’s Hospital and Medical Center, Phoenix, AZ 85013, USA; (E.B.); (B.N.); (D.S.F.); (X.Z.); (M.A.M.); (W.L.W.); (A.S.L.)
| | - William L. White
- The Loyal and Edith Davis Neurosurgical Research Laboratory, Department of Neurosurgery, Barrow Neurological Institute, St. Joseph’s Hospital and Medical Center, Phoenix, AZ 85013, USA; (E.B.); (B.N.); (D.S.F.); (X.Z.); (M.A.M.); (W.L.W.); (A.S.L.)
| | - Jessica K. Daniels
- Department of Neuropathology, Barrow Neurological Institute, St. Joseph’s Hospital and Medical Center, Phoenix, AZ 85013, USA; (J.K.D.); (J.M.E.)
| | - Andrew S. Little
- The Loyal and Edith Davis Neurosurgical Research Laboratory, Department of Neurosurgery, Barrow Neurological Institute, St. Joseph’s Hospital and Medical Center, Phoenix, AZ 85013, USA; (E.B.); (B.N.); (D.S.F.); (X.Z.); (M.A.M.); (W.L.W.); (A.S.L.)
| | - Jennifer M. Eschbacher
- Department of Neuropathology, Barrow Neurological Institute, St. Joseph’s Hospital and Medical Center, Phoenix, AZ 85013, USA; (J.K.D.); (J.M.E.)
| | - Mark C. Preul
- The Loyal and Edith Davis Neurosurgical Research Laboratory, Department of Neurosurgery, Barrow Neurological Institute, St. Joseph’s Hospital and Medical Center, Phoenix, AZ 85013, USA; (E.B.); (B.N.); (D.S.F.); (X.Z.); (M.A.M.); (W.L.W.); (A.S.L.)
- Correspondence: ; Tel.: +1-602-406-3593
| |
Collapse
|
16
|
Sibai M, Mehidine H, Moawad EK, Juchaux M, Varlet P, Devaux B, Abi Haidar D. Comparison of optically-derived biomarkers in healthy and brain tumor tissue under one- and two-photon excitation. JOURNAL OF BIOPHOTONICS 2019; 12:e201900111. [PMID: 31276313 DOI: 10.1002/jbio.201900111] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/25/2019] [Revised: 07/02/2019] [Accepted: 07/04/2019] [Indexed: 06/09/2023]
Abstract
The surgical outcome of brain tumor resection and needle biopsy is significantly correlated to the patient's prognosis. Brain tumor surgery is limited to resecting the solid portion of the tumor as current intraoperative imaging modalities are incapable of delineating infiltrative regions. For accurate delineation, in situ tissue interrogation at the submicron scale is warranted. Additionally, multimodal detection is required to remediate the genetically and molecularly heterogeneous nature of brain tumors, notably, that of gliomas, meningioma and brain metastasis. Multimodal detection, such as spectrally- and temporally-resolved fluorescence under one- and two-photon excitation, enables characterizing tissue based on several endogenous optical contrasts. In order to assign the optically-derived parameters to different tissue types, construction of an optical database obtained from biopsied tissue is warranted. This report showcases the different quantitative and semi-quantitative optical markers that may comprise the tissue discrimination database. These include: the optical index ratio, the optical redox ratio, the relative collagen density, spectrally-resolved fluorescence lifetime parameters, two-photon fluorescence imaging and second harmonic generation imaging.
Collapse
Affiliation(s)
- Mira Sibai
- Imagerie et Modélisation en Neurobiologie et Cancérologie (IMNC), CNRS, Univ Paris Sud, Université Paris-Saclay, Orsay, France
- Université de Paris, IMNC, Orsay, France
| | - Hussein Mehidine
- Imagerie et Modélisation en Neurobiologie et Cancérologie (IMNC), CNRS, Univ Paris Sud, Université Paris-Saclay, Orsay, France
- Université de Paris, IMNC, Orsay, France
| | - Emile Kaadou Moawad
- Imagerie et Modélisation en Neurobiologie et Cancérologie (IMNC), CNRS, Univ Paris Sud, Université Paris-Saclay, Orsay, France
- Université de Paris, IMNC, Orsay, France
| | - Marjorie Juchaux
- Imagerie et Modélisation en Neurobiologie et Cancérologie (IMNC), CNRS, Univ Paris Sud, Université Paris-Saclay, Orsay, France
- Université de Paris, IMNC, Orsay, France
| | - Pascale Varlet
- Neuropathology Department, Sainte-Anne Hospital, Paris, France
- IMA BRAIN, INSERMU894, Centre de Psychiatrie et de Neurosciences, Paris, France
- Paris Descartes University, Paris, France
| | - Bertrand Devaux
- Paris Descartes University, Paris, France
- Neurosurgery Department, Sainte-Anne Hospital, Paris, France
| | - Darine Abi Haidar
- Imagerie et Modélisation en Neurobiologie et Cancérologie (IMNC), CNRS, Univ Paris Sud, Université Paris-Saclay, Orsay, France
- Université de Paris, IMNC, Orsay, France
| |
Collapse
|
17
|
Schebesch KM, Rosengarth K, Brawanski A, Proescholdt M, Wendl C, Höhne J, Ott C, Lamecker H, Doenitz C. Clinical Benefits of Combining Different Visualization Modalities in Neurosurgery. Front Surg 2019; 6:56. [PMID: 31632980 PMCID: PMC6781653 DOI: 10.3389/fsurg.2019.00056] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2018] [Accepted: 09/04/2019] [Indexed: 12/30/2022] Open
Abstract
The prevailing philosophy in oncologic neurosurgery, has shifted from maximally invasive resection to the preservation of neurologic function. The foundation of safe surgery is the multifaceted visualization of the target region and the surrounding eloquent tissue. Recent advancements in pre-operative and intraoperative visualization modalities have changed the face of modern neurosurgery. Metabolic and functional data can be integrated into intraoperative guidance software, and fluorescent dyes under dedicated filters can potentially visualize patterns of blood flow and better define tumor borders or isolated tumor foci. High definition endoscopes enable the depiction of tiny vessels and tumor extension to the ventricles or skull base. Fluorescein sodium-based confocal endomicroscopy, which is under scientific evaluation, may further enhance the neurosurgical armamentarium. We aim to present our institutional workup of combining different neuroimaging modalities for surgical neuro-oncological procedures. This institutional algorithm (IA) was the basis of the recent publication by Haj et al. describing outcome and survival data of consecutive patients with high grade glioma (HGG) before and after the introduction of our Neuro-Oncology Center.
Collapse
Affiliation(s)
| | - Katharina Rosengarth
- Department of Neurosurgery, University Medical Center Regensburg, Regensburg, Germany
| | - Alexander Brawanski
- Department of Neurosurgery, University Medical Center Regensburg, Regensburg, Germany
| | - Martin Proescholdt
- Department of Neurosurgery, University Medical Center Regensburg, Regensburg, Germany
| | - Christina Wendl
- Department of Radiology, University Medical Center Regensburg, Regensburg, Germany
| | - Julius Höhne
- Department of Neurosurgery, University Medical Center Regensburg, Regensburg, Germany
| | - Christian Ott
- Department of Neurosurgery, University Medical Center Regensburg, Regensburg, Germany
| | | | - Christian Doenitz
- Department of Neurosurgery, University Medical Center Regensburg, Regensburg, Germany
| |
Collapse
|
18
|
Charalampaki P, Nakamura M, Athanasopoulos D, Heimann A. Confocal-Assisted Multispectral Fluorescent Microscopy for Brain Tumor Surgery. Front Oncol 2019; 9:583. [PMID: 31380264 PMCID: PMC6657348 DOI: 10.3389/fonc.2019.00583] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2019] [Accepted: 06/14/2019] [Indexed: 01/14/2023] Open
Abstract
Optimal surgical therapy for brain tumors is the combination of complete resection with minimal invasion and damage to the adjacent normal tissue. To achieve this goal, we need advanced imaging techniques on a scale from macro- to microscopic resolution. In the last decade, the development of fluorescence-guided surgery has been the most influential breakthrough, marginally improving outcomes in brain tumor surgery. Multispectral fluorescence microscopy (MFL) is a novel imaging technique that allows the overlapping of a fluorescent image and a white light image in real-time, with delivery of the merged image to the surgeon through the eyepieces of a surgical microscope. MFL permits the detection and characterization of brain tumors using fluorescent molecular markers such as 5-aminolevulinic acid (5-ALA) or indocyanine green (ICG), while simultaneously obtaining high definition white light images to create a pseudo-colored composite image in real-time. Limitations associated with the use of MFL include decreased light imaging intensity and decreased levels of magnification that may compromise maximal tumor resection on a cellular scale. Confocal laser endomicroscopy (CLE) is another novel advanced imaging technique that is based on miniaturization of the microscope imaging head in order to provide the possibility of in vivo microscopy at the cellular level. Clear visualization of the cellular cytoarchitecture can be achieved with 400-fold-1,000-fold magnification. CLE allows on the one hand the intra-operative detection and differentiation of single tumor cells (without the need for intra-operative histologic analysis of biopsy specimens) as well as the definition of borders between tumor and normal tissue at a cellular level, dramatically improving the accuracy of surgical resection. The application and implementation of CLE-assisted surgery in surgical oncology increases not only the number of options for real-time diagnostic imaging, but also the therapeutic options by extending the resection borders of cancer at a cellular level and, more importantly, by protecting the functionality of normal tissue in the adjacent areas of the human brain. In this article, we describe our experience using these new techniques of confocal-assisted fluorescent surgery including analysis on the technology, usability, indications, limitations, and further developments.
Collapse
Affiliation(s)
- Patra Charalampaki
- Department of Neurosurgery, Cologne Medical Center, University Witten-Herdecke, Witten, Germany
| | - Makoto Nakamura
- Department of Neurosurgery, Cologne Medical Center, University Witten-Herdecke, Witten, Germany
| | | | - Axel Heimann
- Institute of Neurosurgical Pathophysiology, Medical University Mainz, Mainz, Germany
| |
Collapse
|
19
|
Belykh E, Miller EJ, Carotenuto A, Patel AA, Cavallo C, Martirosyan NL, Healey DR, Byvaltsev VA, Scheck AC, Lawton MT, Eschbacher JM, Nakaji P, Preul MC. Progress in Confocal Laser Endomicroscopy for Neurosurgery and Technical Nuances for Brain Tumor Imaging With Fluorescein. Front Oncol 2019; 9:554. [PMID: 31334106 PMCID: PMC6616132 DOI: 10.3389/fonc.2019.00554] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2019] [Accepted: 06/06/2019] [Indexed: 12/12/2022] Open
Abstract
Background: Previous studies showed that confocal laser endomicroscopy (CLE) images of brain tumors acquired by a first-generation (Gen1) CLE system using fluorescein sodium (FNa) contrast yielded a diagnostic accuracy similar to frozen surgical sections and histologic analysis. We investigated performance improvements of a second-generation (Gen2) CLE system designed specifically for neurosurgical use. Methods: Rodent glioma models were used for in vivo and rapid ex vivo CLE imaging. FNa and 5-aminolevulinic acid were used as contrast agents. Gen1 and Gen2 CLE images were compared to distinguish cytoarchitectural features of tumor mass and margin and surrounding and normal brain regions. We assessed imaging parameters (gain, laser power, brightness, scanning speed, imaging depth, and Z-stack [3D image acquisition]) and evaluated optimal values for better neurosurgical imaging performance with Gen2. Results: Efficacy of Gen1 and Gen2 was similar in identifying normal brain tissue, vasculature, and tumor cells in masses or at margins. Gen2 had smaller field of view, but higher image resolution, and sharper, clearer images. Other advantages of the Gen2 were auto-brightness correction, user interface, image metadata handling, and image transfer. CLE imaging with FNa allowed identification of nuclear and cytoplasmic contours in tumor cells. Injection of higher dosages of FNa (20 and 40 mg/kg vs. 0.1–8 mg/kg) resulted in better image clarity and structural identification. When used with 5-aminolevulinic acid, CLE was not able to detect individual glioma cells labeled with protoporphyrin IX, but overall fluorescence intensity was higher (p < 0.01) than in the normal hemisphere. Gen2 Z-stack imaging allowed a unique 3D image volume presentation through the focal depth. Conclusion: Compared with Gen1, advantages of Gen2 CLE included a more responsive and intuitive user interface, collection of metadata with each image, automatic Z-stack imaging, sharper images, and a sterile sheath. Shortcomings of Gen2 were a slightly slower maximal imaging speed and smaller field of view. Optimal Gen2 imaging parameters to visualize brain tumor cytoarchitecture with FNa as a fluorescent contrast were defined to aid further neurosurgical clinical in vivo and rapid ex vivo use. Further validation of the Gen2 CLE for microscopic visualization and diagnosis of brain tumors is ongoing.
Collapse
Affiliation(s)
- Evgenii Belykh
- Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, AZ, United States.,Department of Neurosurgery, Irkutsk State Medical University, Irkutsk, Russia
| | - Eric J Miller
- Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, AZ, United States
| | - Alessandro Carotenuto
- Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, AZ, United States
| | - Arpan A Patel
- Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, AZ, United States
| | - Claudio Cavallo
- Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, AZ, United States
| | - Nikolay L Martirosyan
- Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, AZ, United States
| | - Debbie R Healey
- Department of Neuro-Oncology Research, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, AZ, United States
| | - Vadim A Byvaltsev
- Department of Neurosurgery, Irkutsk State Medical University, Irkutsk, Russia
| | - Adrienne C Scheck
- Department of Neuro-Oncology Research, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, AZ, United States
| | - Michael T Lawton
- Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, AZ, United States
| | - Jennifer M Eschbacher
- Department of Neuropathology, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, AZ, United States
| | - Peter Nakaji
- Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, AZ, United States
| | - Mark C Preul
- Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, AZ, United States
| |
Collapse
|
20
|
Wei L, Fujita Y, Sanai N, Liu JTC. Toward Quantitative Neurosurgical Guidance With High-Resolution Microscopy of 5-Aminolevulinic Acid-Induced Protoporphyrin IX. Front Oncol 2019; 9:592. [PMID: 31334117 PMCID: PMC6616084 DOI: 10.3389/fonc.2019.00592] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2019] [Accepted: 06/17/2019] [Indexed: 12/13/2022] Open
Abstract
Low-power fluorescence microscopy of 5-ALA-induced PpIX has emerged as a valuable intraoperative imaging technology for improving the resection of malignant gliomas. However, current fluorescence imaging tools are not highly sensitive nor quantitative, which limits their effectiveness for optimizing operative decisions near the surgical margins of gliomas, in particular non-enhancing low-grade gliomas. Intraoperative high-resolution optical-sectioning microscopy can potentially serve as a valuable complement to low-power fluorescence microscopy by providing reproducible quantification of tumor parameters at the infiltrative margins of diffuse gliomas. In this forward-looking perspective article, we provide a brief discussion of recent technical advancements, pilot clinical studies, and our vision of the future adoption of handheld optical-sectioning microscopy at the final stages of glioma surgeries to enhance the extent of resection. We list a number of challenges for clinical acceptance, as well as potential strategies to overcome such obstacles for the surgical implementation of these in vivo microscopy techniques.
Collapse
Affiliation(s)
- Linpeng Wei
- Department of Mechanical Engineering, University of Washington, Seattle, WA, United States
| | - Yoko Fujita
- Department of Neurological Surgery, Barrow Neurological Institute, Phoenix, AZ, United States
| | - Nader Sanai
- Department of Neurological Surgery, Barrow Neurological Institute, Phoenix, AZ, United States
| | - Jonathan T C Liu
- Department of Mechanical Engineering, University of Washington, Seattle, WA, United States.,Department of Pathology, University of Washington School of Medicine, Seattle, WA, United States
| |
Collapse
|