1
|
Ávila Filho SH, Moura VMBD, Queiroz PJB, Faleiro MBR, Lima BSG, Freitas SLR, Santos AS, Silva LAF. Chitosan thread in the healing of the cecal wall of rabbits (Oryctolagus cuniculus) submitted to cecorrhaphy. J Biomed Mater Res B Appl Biomater 2024; 112:e35314. [PMID: 37565785 DOI: 10.1002/jbm.b.35314] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2023] [Revised: 07/03/2023] [Accepted: 08/01/2023] [Indexed: 08/12/2023]
Abstract
The development and evaluation of synthesis materials are crucial to reducing the morbidity and magnitude of post-enterorrhaphy surgical complications. Despite the possibility of production, chitosan thread has not yet been used in enterorrhaphy, and its effects on intestinal healing have not been evaluated. Therefore, this study aimed to evaluate the effects of chitosan thread on the intestinal wall repair of rabbits submitted to cecorrhaphy. For this, 42 rabbits were allocated into two groups with 21 animals. One group was submitted to cecorrhaphy with chitosan suture thread (CG) and the other with poliglecaprone suture thread (PG). The occurrence of postoperative complications, the intensity of edema, cellular response, formation of granulation tissue, as well as the deposition and maturation of collagen fibers, and the intensity of vascular endothelial growth factor (VEGF-α) expression, were evaluated during the intestinal wall repair process. The evaluations occurred on the 5th, 15th, and 25th postoperative (PO) days. The animals did not develop peritonitis, but adherence was observed in six animals from CG and seven from PG, with no difference between groups. The polymorphonuclear infiltrate showed higher intensity and higher amount of type III collagen fibers in CG on the 15th PO day. In contrast, a lower amount of type I collagen fibers was observed in CG samples on the 25th PO day. Therefore, the chitosan thread used for cecorrhaphy in rabbits results in minimal postoperative complications, presents biocompatibility, and bioactively assists the tissue repair process of the cecal wall, inducing minimal tissue reaction, stimulating the deposition of type III collagen fibers in the proliferative phase, with sustained VEGF-α expression, but with reduced deposition of type I fibers, indicating a delay in collagen maturation.
Collapse
Affiliation(s)
- S H Ávila Filho
- Department of Veterinary Surgery, Federal University Goiás and Goiano Federal Institute, Goiás, Brazil
| | - V M B D Moura
- Department of Veterinary Pathology, Federal University Goiás, Goiás, Brazil
| | - P J B Queiroz
- Department of Veterinary Surgery, Federal University Goiás, Goiás, Brazil
| | - M B R Faleiro
- Department of Veterinary Pathology, Federal University Goiás, Goiás, Brazil
| | - B S G Lima
- Department of Veterinary Pathology, Federal University Goiás, Goiás, Brazil
| | - S L R Freitas
- Department of Veterinary Surgery, Goiano Federal Institute, Goiás, Brazil
| | - A S Santos
- Department of Veterinary Pathology, Goiano Federal Institute, Goiás, Brazil
| | - L A F Silva
- Department of Veterinary Surgery, Federal University Goiás, Goiás, Brazil
| |
Collapse
|
2
|
Blumenthal M, Bertran J, Regier P, Cole J, Maxwell EA. Evaluation of automated staple sizes on gastric layer incorporation and intraluminal pressure for partial gastrectomy closure in an ex vivo canine model. Vet Med Sci 2023; 9:2586-2593. [PMID: 37817443 PMCID: PMC10650250 DOI: 10.1002/vms3.1294] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Revised: 08/24/2023] [Accepted: 09/22/2023] [Indexed: 10/12/2023] Open
Abstract
OBJECTIVE To evaluate the performance of automated staple sizes on a cadaveric canine partial gastrectomy model. METHODS Stomachs were transected through the gastric body axis and randomly allocated to two closure groups: Group B, thoracoabdominal (TA) stapler 3.5 mm staple cartridge (blue); Group G, TA stapler 4.8 mm staple cartridge (green). After construct completion, leak testing was performed for both groups and compared. Initial leakage pressure (ILP), maximal leakage pressure (MLP) and leakage location were recorded. Staple lines were evaluated by direct observation and fluoroscopy to assess sub-mucosal layer incorporation and staple conformation. Staple shape was classified as optimal or suboptimal. Significance was set at p less than 0.5. RESULTS Following gastrectomy, the mean double gastric wall thickness was 7.82 ± 2.05 mm at the gastric body. Mean ILP was significantly lower in groups G (17.13 ± 1.19 mmHg) compared to group B (50.46 ± 6.03 mmHg, p = 0.0013). Similarly, mean MLP was significantly lower in group G (21.41 ± 1.39 mmHg) compared to group B (64.61 ± 10.21 mmHg, p < 0.0001). Although group G had higher percentage of B-shaped staple formation compared to group B, this was not significant (group G; 92.38%, group B; 54.56%; p = 0.054). CONCLUSION The 3.5 mm TA staple cartridge (blue) achieved superior bursting pressures compared with the 4.8 mm TA staple cartridge (blue) for the closure of a canine partial gastrectomy model. Both staple sizes incorporated all gastric layers. No differences were noticed in optimal staple conformation between groups. In vivo investigation is warranted to evaluate the use of different staple sizes on gastric tissue perfusion, successful healing and post-operative stasis and dehiscence.
Collapse
Affiliation(s)
- Michael Blumenthal
- Small Animal Clinical Sciences DepartmentUniversity of FloridaGainesvilleFloridaUSA
| | - Judith Bertran
- Small Animal Clinical Sciences DepartmentUniversity of FloridaGainesvilleFloridaUSA
| | - Penny Regier
- Small Animal Clinical Sciences DepartmentUniversity of FloridaGainesvilleFloridaUSA
| | - James Cole
- Small Animal Clinical Sciences DepartmentUniversity of FloridaGainesvilleFloridaUSA
| | - Elizabeth A Maxwell
- Small Animal Clinical Sciences DepartmentUniversity of FloridaGainesvilleFloridaUSA
| |
Collapse
|
3
|
Williams EA, Monnet E. Clinical outcomes of the use of unidirectional barbed sutures in gastrointestinal surgery for dogs and cats: A retrospective study. Vet Surg 2023; 52:1009-1014. [PMID: 37332126 DOI: 10.1111/vsu.13978] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2022] [Revised: 04/26/2023] [Accepted: 05/29/2023] [Indexed: 06/20/2023]
Abstract
OBJECTIVE To report the clinical outcomes of gastrointestinal surgery using unidirectional barbed sutures in single-layer appositional closure in dogs and cats. STUDY DESIGN Retrospective and descriptive study. SAMPLE POPULATION Twenty-six client-owned dogs; three client-owned cats. METHODS Medical records of dogs and cats that received gastrointestinal surgery closed with unidirectional barbed sutures were reviewed to collect information on signalment, physical examinations, diagnostics, surgical procedures, and complications. Short- and long-term follow-up information was collected from the medical records, the owners, or the referring veterinarians. RESULTS Six gastrotomies, 21 enterotomies, and nine enterectomies were closed with a simple continuous pattern with unidirectional barbed glycomer 631 sutures. Nine dogs had multiple surgical sites closed with unidirectional barbed sutures. None of the cases in the study developed leakage, dehiscence, or septic peritonitis during the 14-day short-term follow up. Long-term follow up information was collected for 19 patients. The median long-term follow-up time was 1076 days (range: 20-2179 days). Two dogs had intestinal obstruction due to strictures at the surgical site 20 and 27 days after surgery. Both were resolved with an enterectomy of the original surgical site. CONCLUSION Unidirectional barbed suture was not associated with a risk of leakage or dehiscence after gastrointestinal surgery in dogs and cats. However, strictures may develop in the long term. CLINICAL SIGNIFICANCE Unidirectional barbed sutures can be used during gastrointestinal surgery in client-owned dogs and cats. Further investigation of the role of unidirectional barbed sutures leading to abscess, fibrosis, or stricture is necessary.
Collapse
Affiliation(s)
- Evan A Williams
- Department of Clinical Sciences, Colorado State University, Fort Collins, Colorado, USA
| | - Eric Monnet
- Department of Clinical Sciences, Colorado State University, Fort Collins, Colorado, USA
| |
Collapse
|
4
|
Liu C, Wang Y, Zhao AR, Hu FA, Fan Q, Han G, Ding G, Fu T, Geng L, Yin H. An alternative asymmetric figure-of-eight single-layer suture technique for bowel anastomosis in an in vitro porcine model. Front Surg 2022; 9:896542. [PMID: 36248362 PMCID: PMC9554239 DOI: 10.3389/fsurg.2022.896542] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2022] [Accepted: 09/05/2022] [Indexed: 11/13/2022] Open
Abstract
Anastomotic techniques are of vital importance in restoring gastrointestinal continuity after resection. An alternative asymmetric figure-of-eight single-layer suture anastomotic technique was introduced and its effects were evaluated in an in vitro porcine model. Twelve 15-cm grossly healthy small intestine segments from a porcine cadaver were harvested and randomly divided into asymmetric figure-of-eight single-layer suture (figure-of-eight suture) and single-layer interrupted suture technique (interrupted suture) groups (n = 6 in each group). The anastomosed bowel was infused with methylene blue solution to test anastomotic leakage. Anastomosis construction time, leakage, and suture material cost were recorded and analyzed statistically using Fisher's exact test and Student's t-test. One anastomotic leakage occurred (16.67%) in the figure-of-eight suture group, and two (33.33%) in the interrupted suture group (p > 0.9999). The anastomosis construction time was relatively short in the figure-of-eight suture group, but the difference did not reach a statistically significant level between the two groups. The mean number of suture knots and the cost of suture material in the figure-of-eight suture group were significantly decreased in comparison to the interrupted suture group (15.67 ± 3.30 vs. 22.17 ± 2.03, 167.11 ± 35.20 vs. 236.45 ± 21.70 CNY, p < 0.01, respectively). Our results suggested that the alternative asymmetric figure-of-eight suture technique was safe and economic for intestinal anastomosis. An in vivo experiment is required to elucidate the effects of this suture technique on the physiological anastomotic healing process.
Collapse
Affiliation(s)
- Chen Liu
- The Department of Pediatric Surgery, Binzhou Medical University Hospital, Binzhou, China
- The Department of Surgery, Shanghai Children's Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Yewen Wang
- The Department of Pediatric Surgery, Binzhou Medical University Hospital, Binzhou, China
| | - Ai-rong Zhao
- The Department of Pharmacy, Binzhou Medical University Hospital, Binzhou, China
| | - Feng-ai Hu
- The Clinical Laboratory, Binzhou Medical University Hospital, Binzhou, China
| | - Qizhong Fan
- The Department of Pharmacy, Binzhou Medical University Hospital, Binzhou, China
| | - Guoxiu Han
- The Department of Pediatric Surgery, Binzhou Medical University Hospital, Binzhou, China
| | - Guojian Ding
- The Department of Pediatric Surgery, Binzhou Medical University Hospital, Binzhou, China
| | - Tingliang Fu
- The Department of Pediatric Surgery, Binzhou Medical University Hospital, Binzhou, China
| | - Lei Geng
- The Department of Pediatric Surgery, Binzhou Medical University Hospital, Binzhou, China
- Correspondence: Lei Geng Hongshan Yin
| | - Hongshan Yin
- The Department of Urology, Binzhou Medical University Hospital, Binzhou, China
- Correspondence: Lei Geng Hongshan Yin
| |
Collapse
|
5
|
Duffy DJ, Chang YJ, Moore GE. Influence of barbed suture oversew of the transverse staple line during functional end-to-end stapled anastomosis in a canine jejunal enterectomy model. Vet Surg 2022; 51:801-808. [PMID: 35614547 PMCID: PMC9324082 DOI: 10.1111/vsu.13827] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2021] [Revised: 02/14/2022] [Accepted: 04/22/2022] [Indexed: 11/30/2022]
Abstract
Objective To evaluate the influence of barbed suture oversew of the transverse staple line during functional end‐to‐end stapled anastomosis (FEESA) in dogs. Study design Randomized, experimental, ex vivo. Animals or sample population Grossly normal jejunal segments from 14 adult canine cadavers. Methods Ninety‐eight jejunal segments (n = 14/FEESA group, n = 14 controls) were harvested and randomly assigned to a control group, FEESA + monofilament suture oversew, FEESA + unidirectional barbed suture oversew or FEESA + bidirectional barbed suture oversew. Oversew techniques were performed using a Cushing suture pattern. Initial (ILP) and maximum leakage pressure (MLP), repair time (s), and location of observed leakage were recorded. Results No differences were detected in ILP (p = .439) or MLP (p = .644) respectively between experimental groups. Repairs times using barbed suture were ~ 18% faster (~25 s faster; p < .001) compared to monofilament suture. There was no difference between barbed suture types (p = .697). Mean ILP (p < .001) and MLP (p < .0001) were 6.6x and 5.1x greater respectively in the control group. Leakage location occurred predominately at the crotch of the FEESA in all groups. Conclusion FEESAs closed with a transverse staple line oversew using barbed suture, regardless of barb orientation, were completed faster and resulted in similar resistance to anastomotic leakage compared to monofilament suture. Clinical significance Oversewing the transverse staple line following FEESA using barbed suture offers similar resistance to anastomotic leakage, and may be associated with decreased surgical times in dogs compared to monofilament suture. Further studies are necessary to determine the benefits of barbed suture use in both open and laparoscopic gastrointestinal surgical applications following FEESA in dogs.
Collapse
Affiliation(s)
- Daniel J Duffy
- Department of Clinical Sciences, College of Veterinary Medicine, Purdue University, West Lafayette, Indiana, USA
| | - Yi-Jen Chang
- Department of Clinical Sciences, College of Veterinary Medicine, Purdue University, West Lafayette, Indiana, USA
| | - George E Moore
- Veterinary Administration, College of Veterinary Medicine, Purdue University, West Lafayette, Indiana, USA
| |
Collapse
|
6
|
Quitzan JG, Singh A, Beaufrère H, Saleh TM. Influence of staple line number and configuration on the leakage of small intestinal functional end‐to‐end stapled anastomosis: An ex vivo study. Vet Surg 2022; 51:781-787. [DOI: 10.1111/vsu.13818] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2021] [Revised: 02/23/2022] [Accepted: 04/11/2022] [Indexed: 11/28/2022]
Affiliation(s)
- Juliany Gomes Quitzan
- School of Veterinary Medicine and Animal Science Sao Paulo State University Botucatu Sao Paulo Brazil
- Department of Clinical Studies, Ontario Veterinary College University of Guelph Guelph Ontario Canada
| | - Ameet Singh
- Department of Clinical Studies, Ontario Veterinary College University of Guelph Guelph Ontario Canada
| | - Hugues Beaufrère
- Department of Clinical Studies, Ontario Veterinary College University of Guelph Guelph Ontario Canada
| | - Tarek M. Saleh
- Department of Biomedical Sciences, Ontario Veterinary College University of Guelph Guelph Ontario Canada
| |
Collapse
|
7
|
Regier PJ. Current Concepts in Small Animal Gastrointestinal Surgery. Vet Clin North Am Small Anim Pract 2022; 52:437-454. [DOI: 10.1016/j.cvsm.2021.11.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
8
|
Chang YJ, Duffy DJ, Moore GE. Influence of preconstructed effector loop location using a barbed unidirectional suture on leakage pressures following canine enterotomy closure. Vet Surg 2021; 50:1502-1509. [PMID: 34405426 DOI: 10.1111/vsu.13710] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2021] [Revised: 07/12/2021] [Accepted: 07/30/2021] [Indexed: 11/29/2022]
Abstract
OBJECTIVE To evaluate the influence of preconstructed effector loop location using a barbed unidirectional suture on leakage pressures following canine enterotomy closure. STUDY DESIGN Randomized, experimental, cadaveric. ANIMALS OR SAMPLE POPULATION Grossly normal jejunal segments from three canine cadavers. METHODS Jejunal segments were harvested and randomly assigned based upon effector loop location from the beginning of the incisional line. Groups (n = 12/group) included 0 mm, 5 mm, 10 mm, 15 mm, and intact controls (n = 6/group), repaired using a 3-0 unidirectional barbed suture in a simple continuous pattern. Initial leakage pressure (ILP), maximum intraluminal pressure (MIP), repair time, and leakage location were recorded. RESULTS Mean ILP for 0 mm group (24.42 ± 8.43 mmHg) was lower (p ≤ .001) compared to all experimental groups with ILP ~40% lower. There was no difference in MIP among experimental groups (p = .239). Repair time increased (p < .0001) as the distance of the effector loop increased ≥5 mm from the beginning of the incisional line. Leakage location differed among groups (p < .001) with leakage in the 0 mm group from the incisional line (75%), compared to leakage from predominantly from the suture holes in other groups, respectively. CONCLUSION Effector loop location influenced ILP and leakage location. Effector loops placed at the beginning of the incisional line (0 mm) decreased ILP compared to loops placed at 5, 10, and 15 mm. CLINICAL SIGNIFICANCE Effector loop location using a unidirectional barbed suture should be placed ≥5 mm from beginning of the incisional line for enterotomy closure. Further in vivo studies are necessary to determine the clinical significance of these findings.
Collapse
Affiliation(s)
- Yi-Jen Chang
- Department of Clinical Sciences, College of Veterinary Medicine, North Carolina State University, Raleigh, North Carolina, USA
| | - Daniel J Duffy
- Department of Clinical Sciences, College of Veterinary Medicine, North Carolina State University, Raleigh, North Carolina, USA
| | - George E Moore
- Veterinary Administration, College of Veterinary Medicine, Purdue University, West Lafayette, Indiana, USA
| |
Collapse
|
9
|
Culbertson TF, Smeak DD, Pogue JM, Vitt MA, Downey AC. Intraoperative surgeon probe inspection compared to leak testing for detecting gaps in canine jejunal continuous anastomoses: A cadaveric study. Vet Surg 2021; 50:1472-1482. [PMID: 34374997 DOI: 10.1111/vsu.13708] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2020] [Revised: 07/25/2021] [Accepted: 07/26/2021] [Indexed: 12/16/2022]
Abstract
OBJECTIVE To compare the detection of gaps in jejunal continuous anastomoses by probing (PT) versus leak testing (LT). STUDY DESIGN Experimental study. ANIMALS Normal jejunal segments (n = 24) from two fresh canine cadavers. METHODS Intestinal segments were randomly selected by four volunteers who created six simple continuous anastomoses: two constructs using standard technique with 2-3 mm suture spacing (ST, 8 total), and four constructs with one 4-mm gap (IG, 16 total). All 24 anastomoses were examined with PT (1 volunteer) prior to LT (3 volunteers). LT was performed within a maximal peristaltic pressure range (34-54 cmH2 O). The presence and location of anastomotic leaks (LA ) detected with LT were compared with gaps detected with PT. RESULTS Nineteen out of twenty-four (79.2%) samples had at least one probe drop, and four out of twenty-three (17.4%) samples leaked. LT results from one sample were excluded due to iatrogenic suture failure. PT was 100% sensitive (95% CI: 51.01, 100%) with a 100% negative predictive value (95% CI: 56.55, 100%) at detecting gaps compared with LT. The location of all LA was accurately identified with PT and confirmed during LT. CONCLUSION PT was highly sensitive at detecting gaps compared with LT. All LA were accurately detected by PT. None of the segments negative during PT leaked. CLINICAL SIGNIFICANCE The diagnostic value of PT appears adequate to recognize gaps in cadaveric small intestinal anastomoses. PT offers surgeons an alternative to detect suture gaps that may contribute to postoperative dehiscence of intestinal anastomoses.
Collapse
Affiliation(s)
- Tricia F Culbertson
- Department of Clinical Sciences, Colorado State University, Fort Collins, Colorado, USA
| | - Daniel D Smeak
- Department of Clinical Sciences, Colorado State University, Fort Collins, Colorado, USA
| | - Joanna M Pogue
- Department of Clinical Sciences, Colorado State University, Fort Collins, Colorado, USA
| | - Molly A Vitt
- Department of Clinical Sciences, Colorado State University, Fort Collins, Colorado, USA
| | - Amy C Downey
- Department of Clinical Sciences, Colorado State University, Fort Collins, Colorado, USA
| |
Collapse
|
10
|
Sapora JA, Hafez A, Monnet E. Ex vivo comparison of hand-sutured versus circular stapled anastomosis in canine large intestine. Vet Surg 2021; 50:1495-1501. [PMID: 34355807 DOI: 10.1111/vsu.13705] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2021] [Revised: 06/29/2021] [Accepted: 07/25/2021] [Indexed: 10/20/2022]
Abstract
OBJECTIVE To compare leakage pressures of colonic anastomoses performed with circular staplers to conventional hand-sewn techniques in dogs. STUDY DESIGN Ex-vivo study. ANIMALS Colon from 11 canine cadavers. METHODS Thirty-two colonic anastomoses were performed. Four segments from each colon were randomly assigned to one of four techniques: hand-sewn colonic anastomoses performed with 4-0 glycomer 631 (G) and 4-0 barbed glycomer 631 (BG), and circular stapled colonic anastomoses using 4.8 mm End-to-End Anastomosis (EEA C4.8mm) and 3.5 mm End-to-End Anastomosis (EEA C3.5mm), 21 mm diameter circular staples in cadaveric canine colon. Leakage pressure was defined as the pressure at which dye-containing solution was first observed to leak from the anastomosis site. RESULTS Leakage pressures were 49.5 mmHg (range:16-72) in group G, 45.5 mmHg (range:19-80) in group BG, 5.3 mmHg (range:0-31) in group C3.5mm, and 29.5 mmHg (range:23-50.3) in group C4.8mm. Anastomoses leaked at lower pressures when stapled rather than hand-sewn (C4.8mm-G p = .0313, C4.8mm-BG p = .0131, C3.5mm-G p = .0469, C3.5mm-BG p = .0313). Two of the C3.5mm constructs leaked immediately after saline infusion with 4/6 leaking at <5.3 mmHg. CONCLUSION End-to-end colonic anastomoses closed with circular stapler leaked at lower pressures than hand-sutured anastomoses. Use of the EEA stapler with a staple height of 3.5 mm did not result in safe colonic anastomoses. CLINICAL SIGNIFICANCE These results provide evidence to support hand-suturing colonic anatomoses with G and BG in dogs. The 4.8 mm staples may be considered in anatomical locations difficult to reach.
Collapse
Affiliation(s)
- Joseph A Sapora
- Department of Clinical Sciences, College of Veterinary Medicine and Biomedical Sciences, Colorado State University, Fort Collins, Colorado, USA
| | - Ahmed Hafez
- Faculty of Veterinary Medicine, Department of Surgery, Anesthesiology, and Radiology, Beni-Suef University, Beni-Suef, Egypt
| | - Eric Monnet
- Department of Clinical Sciences, College of Veterinary Medicine and Biomedical Sciences, Colorado State University, Fort Collins, Colorado, USA
| |
Collapse
|
11
|
Lima HCGD, Ribeiro AP, Souza JÁD, Vieira RR, Fernandes MF. Evaluation of barbed suture for celiorrhaphy and subcutaneous closure in bitches with pyometra submitted to ovariohysterectomy. Acta Cir Bras 2021; 36:e360502. [PMID: 34133504 PMCID: PMC8205441 DOI: 10.1590/acb360502] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2021] [Accepted: 04/14/2021] [Indexed: 11/21/2022] Open
Abstract
Purpose To evaluate the use of barbed sutures over the surgical time, the leukogram,
the tissue thickness in which the sutures were employed (ultrasonography),
the costs, and the possible complications in bitches with pyometra submitted
to ovariohysterectomy (OH). Methods Convectional 2.0 polyglyconate suture was used in the control group (CG n =
10) and 2.0 barbed polyglyconate suture in the barbed group (BG n = 10) to
perform celiorrhaphy (simple continuous pattern) and subcutaneous closure
(continuous intradermal pattern). Data were assessed using paired (leukogram
between 24 and 48 h within the same group) and unpaired (leukogram, surgical
time, tissue thickness, and costs) Student’s t-test. The Fisher exact test
was used to assess the occurrence of seroma between groups (p < 0.05).
Results are shown as mean ± standard error of mean. Results The time spent to perform the celiorrhaphy (195.30 ± 17.37 s vs. 204 ± 16.00
s), subcutaneous closure (174.0 ± 15.86 s vs. 198.0 ± 15.62 s), and the
total surgical time (24.30 ± 1.44 min vs. 23.00 ± 1.30 min) did not differ
between BG and CG, respectively (p > 0.05). Leukogram at 48 h
post-surgery did not differ between groups (p = 0.20). No differences were
observed in the subcutaneous and the abdominal wall thickness (cm) assessed
by ultrasonography at 48 h in BG (0.31 ± 0.04, 0.80 ± 0.05) and CG (0.34 ±
0.03, 0.72 ± 0.06), respectively. Similarly, 15 days post-surgery the same
structures did not differ between BG (0.26 ± 0.02, 0.74 ± 0.08) and CG (0.26
± 0.03, 0.64 ± 0.05) (p > 0.05). In one bitch from each group, a mild
seroma was observed on one side of the surgical wound 48 h after surgery (p
= 1.00). The procedures in which barbed sutures were used had an average
additional cost of R$ 200.00 ± 11.66 (p < 0.0001). Conclusions Barbed suture has proven to be efficient and safe for abdominal and
subcutaneous closure. However, considering its current high cost in addition
thatthe surgical time of bitches with pyometra undergone OH was not reduced,
no advantages were observed with theuse of barbed sutures for this type of
surgery.
Collapse
|
12
|
Lorange M, Smeak DD. Comparison of a simple continuous versus simple interrupted suture pattern for the repair of a large, open duodenal defect with a jejunal serosal patch in a canine cadaveric model. Am J Vet Res 2020; 81:985-991. [PMID: 33251840 DOI: 10.2460/ajvr.81.12.985] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
OBJECTIVE To determine whether jejunal serosal patches could securely seal large, open defects in duodenal segments harvested from canine cadavers and to compare intraluminal pressures at which leakage first occurred and maximal intraluminal pressures for repaired duodenal segments between 2 suture patterns. SAMPLE Duodenal and jejunal segments from 9 canine cadavers. PROCEDURES 20 constructs were created through repair of large, open duodenal defects with circumferential suturing of an intact jejunal segment (jejunal serosal patch). Constructs were randomly assigned to have the serosal patch anastomosed to the duodenal segment by a simple continuous or simple interrupted suture pattern. The pressure at which the first leakage was observed and the maximum pressure obtained during testing were recorded and compared between suture patterns. RESULTS Initial leakage pressure was significantly higher with the simple interrupted pattern (mean ± SD, 68.89 ± 5.62 mm Hg), compared with the simple continuous pattern (59.8 ± 20.03 mm Hg). Maximum intraluminal pressures did not significantly differ between the simple interrupted (91 ± 8.27 mm Hg) and simple continuous patterns (90.7 ± 16.91 mm Hg). All constructs, regardless of suture pattern, withstood supraphysiologic pressures. CONCLUSIONS AND CLINICAL RELEVANCE Jejunal serosal patches adequately sealed large, open duodenal defects and prevented leakage in these constructs. Constructs with simple continuous or simple interrupted suture patterns withstood physiologic and supraphysiologic intraluminal pressures, although constructs with a simple interrupted suture pattern initially leaked at higher pressures. (Am J Vet Res 2020;81:985-991).
Collapse
|
13
|
Regier PJ, Fealey MJ, Kim SE, Case JB, Garcia-Pereira F. Comparison of intestinal leak pressure between cadaveric canine and commercial synthetic intestinal tissue that did and did not undergo enterotomy. Am J Vet Res 2020; 81:827-831. [PMID: 32969730 DOI: 10.2460/ajvr.81.10.827] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
OBJECTIVE To compare initial leak pressure (ILP) between cadaveric canine and synthetic small intestinal segments that did and did not undergo enterotomy. SAMPLE Eight 8-cm grossly normal jejunal segments from 1 canine cadaver and eight 8-cm synthetic small intestinal segments. PROCEDURES Intestinal segments were randomly assigned to undergo enterotomy (6 cadaveric and 6 synthetic segments) or serve as untreated controls (2 cadaveric and 2 synthetic segments). For segments designated for enterotomy, a 2-cm full-thickness incision was created along the antimesenteric border. The incision was closed in a single layer with 4-0 suture in a simple continuous pattern. Leak testing was performed with intestinal segments occluded at both ends and infused with dilute dye solution (999 mL/h) until the solution was observed leaking from the suture line or serosal tearing occurred. Intraluminal pressure was continuously monitored. The ILP at construct failure was compared between cadaveric and synthetic control segments and between cadaveric and synthetic enterotomy segments. RESULTS Mean ± SD ILP did not differ significantly between cadaveric (345.11 ± 2.15 mm Hg) and synthetic (329.04 ± 24.69 mm Hg) control segments but was significantly greater for cadaveric enterotomy segments (60.77 ± 15.81 mm Hg), compared with synthetic enterotomy segments (15.03 ± 6.41 mm Hg). CONCLUSIONS AND CLINICAL RELEVANCE Leak testing should not be used to assess the accuracy or security of enterotomy suture lines in synthetic intestinal tissue. Synthetic intestinal tissue is best used for students to gain confidence and proficiency in performing enterotomies before performing the procedure on live animals.
Collapse
|
14
|
Mullen KM, Regier PJ, Waln M, Fox-Alvarez WA, Colee J. Gastrointestinal thickness, duration, and leak pressure of six intestinal anastomoses in dogs. Vet Surg 2020; 49:1315-1325. [PMID: 32697359 DOI: 10.1111/vsu.13490] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2020] [Revised: 05/17/2020] [Accepted: 06/18/2020] [Indexed: 12/13/2022]
Abstract
OBJECTIVE To compare leak pressures and construct completion time of six intestinal anastomoses and report normal canine gastrointestinal thickness. STUDY DESIGN Experimental study. ANIMALS Grossly normal jejunal segments (n = 140) from 10 fresh canine cadavers. METHODS Gastrointestinal thickness was recorded. Eight-centimeter cooled canine cadaveric jejunal segments were randomly assigned to a control group (20 segments) and six treatment groups (20 segments/group [10 constructs/group]): (1) handsewn anastomosis (HSA), (2) functional end-to-end stapled anastomosis (FEESA)-blue thoracoabdominal (TA; FEESA-TAB), (3) FEESA-green TA (FEESA-TAG), (4) FEESA TA-gastrointestinal anastomosis (GIA), (5) FEESA with suture oversew (FEESA-O), and (6) skin staples (SS). Construct assembly time, initial leak pressure (ILP), maximum intraluminal pressure (MIP), and leakage location were compared. RESULTS Initial leak pressures (mean ± SD) for control (308.38 ± 115.91 mm Hg), HSA (41.96 ± 15.97), FEESA-TAB (31.71 ± 15.71), FEESA-TAG (27.24 ± 14.11), FEESA-GIA (25.62 ± 11.22), FEESA-O (31.01 ± 17.38), and SS (44.42 ± 28.88) groups were compared. No difference in ILP (P > .24) or MIP (P > .17) was detected between treatment groups. Sutured anastomoses took up to 10 times longer to complete (P = .0025). The stomach, duodenum, jejunum, and ileum mural thicknesses (mean ± SD) were 3.99 ± 0.44 mm, 2.34 ± 0.16, 2.49 ± 0.28, and 2.30 ± 0.31, respectively. CONCLUSION The ILP of all anastomoses exceeded maximum intraluminal peristaltic pressures. Stapled anastomoses were faster to complete. CLINICAL SIGNIFICANCE All anastomoses may be considered when performing an intestinal resection and anastomosis, with stapled anastomoses resulting in a shorter surgical time. Canine intestinal thickness may warrant use of a larger staple size.
Collapse
Affiliation(s)
- Kaitlyn M Mullen
- Department of Small Animal Clinical Sciences, College of Veterinary Medicine, University of Florida, Florida, USA
| | - Penny J Regier
- Department of Small Animal Clinical Sciences, College of Veterinary Medicine, University of Florida, Florida, USA
| | - Monica Waln
- Department of Small Animal Clinical Sciences, College of Veterinary Medicine, University of Florida, Florida, USA
| | - W Alexander Fox-Alvarez
- Department of Small Animal Clinical Sciences, College of Veterinary Medicine, University of Florida, Florida, USA
| | - James Colee
- Department of Statistics, College of Liberal Arts and Sciences University of Florida, Florida, USA
| |
Collapse
|
15
|
Duffy DJ, Chang YJ, Balko JA, Moore GE. Effect of presurgical storage conditions on leakage pressures of enterotomy sites closed with unidirectional barbed suture material in fresh, chilled, and frozen-thawed cadaveric canine jejunal specimens. Am J Vet Res 2020; 81:220-226. [PMID: 32101038 DOI: 10.2460/ajvr.81.3.220] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
OBJECTIVE To evaluate the effect of presurgical storage conditions on leakage pressures of enterotomy sites closed with unidirectional barbed suture material in fresh, chilled, and frozen-thawed cadaveric canine jejunal specimens. SAMPLE 36 grossly normal jejunal segments obtained from 4 dog cadavers. PROCEDURES 9 jejunal segments were harvested immediately from each euthanized dog and randomly assigned to be tested within 4 hours after collection (fresh segments), stored at 4°C for 24 hours before testing (chilled segments), or stored at -20°C for 7 days and thawed at 21°C for 6 hours before testing (frozen-thawed segments). For leakage pressure testing, a 3-cm-long antimesenteric enterotomy was performed and repaired with 3-0 unidirectional barbed suture material in a simple continuous pattern in each segment. Time to complete the enterotomy, initial leakage pressure, maximum intraluminal pressure, and leakage location were recorded for each segment. RESULTS Mean ± SD initial leakage pressure for fresh, chilled, and frozen-thawed segments was 52.8 ± 14.9 mm Hg, 51.8 ± 11.9 mm Hg, and 33.3 ± 7.7 mm Hg, respectively. Frozen-thawed segments had significantly lower mean initial leakage pressure, compared with findings for fresh or chilled segments. Time to complete the enterotomy, maximum intraluminal pressure, and leakage location did not differ among groups. CONCLUSIONS AND CLINICAL RELEVANCE Leak pressure testing of cadaveric jejunal segments that are fresh or chilled at 4°C for 24 hours is recommended for enterotomy studies involving barbed suture material in dogs. Freezing and thawing of cadaveric jejunal tissues prior to investigative use is not recommended because leak pressure data may be falsely low.
Collapse
|
16
|
Mullen KM, Regier PJ, Ellison GW, Londoño L. A Review of Normal Intestinal Healing, Intestinal Anastomosis, and the Pathophysiology and Treatment of Intestinal Dehiscence in Foreign Body Obstructions in Dogs. Top Companion Anim Med 2020; 41:100457. [PMID: 32823156 DOI: 10.1016/j.tcam.2020.100457] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2020] [Revised: 06/05/2020] [Accepted: 06/15/2020] [Indexed: 12/18/2022]
Abstract
Small intestinal anastomoses are commonly performed in veterinary medicine following resection of diseased or devitalized intestinal tissue. Traditionally, suture has been employed to anastomose intestinal ends. However, use of intestinal staplers has become increasingly popular due to the ability to produce a rapid anastomosis with purported superior healing properties. Under normal conditions, intestinal healing occurs in three phases: inflammatory, proliferative, and maturation. Dehiscence, a devastating consequence of intestinal anastomosis surgery, most often occurs during the inflammatory phase of healing where the biomechanical strength of the anastomosis is almost entirely dependent on the anastomotic technique (suture or staple line). The resulting septic peritonitis is associated with a staggering morbidity rate upwards of 85% secondary to the severe systemic aberrations and financial burden induced by septic peritonitis and requirement of a second surgery, respectively. Intraoperative and postoperative consideration of the multifactorial nature of dehiscence is required for successful patient management to mitigate recurrence. Moreover, intensive postoperative critical care management is necessitated and includes antibiotic and fluid therapy, vasopressor or colloidal support, and monitoring of the patient's fluid balance and cardiovascular status. An understanding of anastomotic techniques and their relation to intestinal healing will facilitate intraoperative decision-making and may minimize the occurrence of postoperative dehiscence.
Collapse
Affiliation(s)
- Kaitlyn M Mullen
- Department of Small Animal Clinical Sciences, University of Florida, Gainesville, FL, USA
| | - Penny J Regier
- Department of Small Animal Clinical Sciences, University of Florida, Gainesville, FL, USA.
| | - Gary W Ellison
- Department of Small Animal Clinical Sciences, University of Florida, Gainesville, FL, USA
| | - Leonel Londoño
- Department of Small Animal Clinical Sciences, University of Florida, Gainesville, FL, USA
| |
Collapse
|
17
|
Duffy DJ, Moore GE. Influence of oversewing the transverse staple line during functional end-to-end stapled intestinal anastomoses in dogs. Vet Surg 2020; 49:1221-1229. [PMID: 32502297 DOI: 10.1111/vsu.13451] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2020] [Revised: 03/16/2020] [Accepted: 05/02/2020] [Indexed: 12/15/2022]
Abstract
OBJECTIVE To determine the effect of oversewing the transverse staple line after functional end-to-end stapled intestinal anastomoses (FEESA) on canine jejunal leakage pressures. STUDY DESIGN Experimental, ex vivo, randomized study. SAMPLE POPULATION Jejunal segments from three adult canine cadavers. METHODS Jejunal segments were harvested within 2 hours of euthanasia and anastomosed (24 jejunal segments per group, consisting of two segments per construct with n = 12/ group). Constructs were then randomly assigned to receive FEESA alone, FEESA + Cushing oversew, or FEESA + simple-continuous oversew of the transverse staple line with 3-0 polydioxanone. Results for initial leakage pressure (ILP) and maximal leakage pressure (MLP) and initial leakage location (LL) were compared between groups. RESULTS Mean ILP was 1.8-fold higher for FEESA + Cushing oversew (62.4 ± 7.8 mm Hg) compared with FEESA alone and FEESA + simple-continuous oversew (P < .001). Mean MLP were higher for both oversewn techniques compared with FEESA alone (P < .001). Oversewing the transverse staple line with either pattern increased mean MLP by 1.4-fold compared with FEESA alone. Leakage occurred at the level of the transverse staple line in nonoversewn constructs (P < .001). CONCLUSION Oversewing the transverse staple line after FEESA increased MLP and decreased the occurrence of leakage at this location. Oversewing with a Cushing pattern increased ILP compared with oversew with a simple-continuous pattern. CLINICAL SIGNIFICANCE Our results provide evidence to support oversewing the transverse staple line after FEESA. Doing so may reduce the occurrence of postoperative dehiscence. These findings warrant additional focused investigation in vivo through a prospective randomized clinical trial.
Collapse
Affiliation(s)
- Daniel J Duffy
- Department of Clinical Sciences, College of Veterinary Medicine, North Carolina State University, Raleigh, North Carolina
| | - George E Moore
- Department of Veterinary Administration, College of Veterinary Medicine, Purdue University, West Lafayette, Indiana
| |
Collapse
|
18
|
Chu KL, Duffy DJ, Vieson MD, Moore GE. Ex vivo comparison of leakage pressures and leakage location with a novel technique for creation of functional side-to-side canine small intestinal anastomoses. Vet Surg 2020; 49:1024-1034. [PMID: 32255208 DOI: 10.1111/vsu.13408] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2019] [Revised: 04/08/2019] [Accepted: 05/19/2019] [Indexed: 11/27/2022]
Abstract
OBJECTIVE To determine the ability of functional side-to-side small intestinal anastomoses (FSS-SIA) created with an electrothermal bipolar vessel sealing (EBVS) device to resist leakage. STUDY DESIGN Experimental, ex vivo. SAMPLE POPULATION Jejunal segments (n = 130) from 10 healthy canine cadavers. METHODS Four types of anastomoses were created (two segments/construct and 15 constructs/group): EBVS (group A), EBVS + transverse stapling (group B), stapled (group C), and EBVS + suture augmentation (group D). Initial leakage pressure (ILP), initial leakage location (ILL), and maximal intraluminal pressure were compared between groups, and five group A constructs were analyzed histologically. RESULTS Initial leakage pressure was greater in group D than in groups A, B, and C (P < .011). There was a difference in ILL among groups (P = .003). Leakage occurred at the side-to-side intestinal anastomosis fusion line in 13 of 15 (87%) constructs for groups A and B and in nine of 15 (60%) constructs for group D. Maximal intraluminal pressure was greater in group C than in groups A, B, and D (P < .004). Histological examination was consistent with collagenous fusion without cavitation defects. CONCLUSION Functional side-to-side small intestinal anastomosis was consistently achieved with an EBVS device. Augmentation of EBVS anastomoses with simple interrupted sutures along the anastomotic fusion line increased ILP compared with stapled anastomoses. CLINICAL SIGNIFICANCE Despite the success and feasibility of creating an FSS-SIA with an EBVS device, additional in vivo studies are required to determine the effectiveness of intestinal fusion prior to clinical implementation.
Collapse
Affiliation(s)
- Kyle L Chu
- Department of Veterinary Clinical Medicine, College of Veterinary Medicine, University of Illinois, Urbana, Illinois
| | - Daniel J Duffy
- Department of Clinical Sciences, College of Veterinary Medicine, North Carolina State University, Raleigh, North Carolina
| | - Miranda D Vieson
- Department of Veterinary Clinical Medicine, College of Veterinary Medicine, University of Illinois, Urbana, Illinois
| | - George E Moore
- Veterinary Administration, College of Veterinary Medicine, Purdue University, West Lafayette, Indiana
| |
Collapse
|
19
|
Duffy DJ, Chang YJ, Moore GE. Influence of closure technique on leakage pressures in an ex vivo canine typhlectomy model. Vet Surg 2020; 49:1213-1220. [PMID: 32255202 DOI: 10.1111/vsu.13405] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2019] [Revised: 02/10/2020] [Accepted: 02/20/2020] [Indexed: 12/17/2022]
Abstract
OBJECTIVE To determine the influence of three closure techniques on leakage pressures of canine typhlectomies. STUDY DESIGN Experimental, ex vivo. SAMPLE POPULATION Grossly normal cecal segments from 24 adult canine cadavers. METHODS Typhlectomies were assigned to one of three closure techniques: simple continuous closure with a Parker-Kerr pattern with 4-0 polydioxanone (group 1), closure with a 60-mm gastrointestinal stapler loaded with a 3.8-mm staple cartridge (group 2), and placement of a Cushing suture to augment the stapled closure (group 3). The median (range) of initial leakage pressure (ILP) and maximum leakage pressure (MLP) was compared between groups along with leakage location. RESULTS Typhlectomies in group 3 leaked at higher ILP (310 mm Hg; 188-310) than those in groups 1 (43 mm Hg; 31-80) and 2 (109.5 mm Hg; 68-173; P < .0001). Maximum leakage pressure were greater in group 3 than in other groups (P < .0001). Leakage was detected in 20 of 24 (83%) typhlectomies, located at the incisional line in 13 of 24 (54%) specimens and from suture holes in seven of 24 (29%) specimens. CONCLUSION Placement of a Cushing suture pattern to augment stapled incisions improved the ability of typhlectomies to sustain pressure compared with sutured or stapled cadaveric specimens alone. CLINICAL SIGNIFICANCE These results provide evidence to support placement of a Cushing suture pattern to augment the staple line for typhlectomies in dogs, although in vivo studies are required to determine the clinical significance of these findings.
Collapse
Affiliation(s)
- Daniel J Duffy
- Department of Clinical Sciences, College of Veterinary Medicine, North Carolina State University, Raleigh, North Carolina
| | - Yi-Jen Chang
- Department of Clinical Sciences, College of Veterinary Medicine, North Carolina State University, Raleigh, North Carolina
| | - George E Moore
- Veterinary Administration, College of Veterinary Medicine, Purdue University, West Lafayette, Indiana
| |
Collapse
|
20
|
Fealey MJ, Regier PJ, Steadman Bs C, Brad Case J, Garcia-Pereira F. Initial leak pressures of four anastomosis techniques in cooled cadaveric canine jejunum. Vet Surg 2020; 49:480-486. [PMID: 32034924 DOI: 10.1111/vsu.13392] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2019] [Revised: 12/10/2019] [Accepted: 01/11/2020] [Indexed: 12/18/2022]
Abstract
OBJECTIVE To compare the effectiveness of four different intestinal anastomosis techniques at preventing leakage after enterectomy. STUDY DESIGN Experimental study. SAMPLE POPULATION Grossly normal jejunal segments (N = 70) from three fresh canine cadavers. METHODS Eight-centimeter cooled canine cadaveric jejunal segments were randomly assigned to a control group (six segments) and four treatment groups (16 segments each [two segments/anastomotic construct]): (1) handsewn anastomosis (HSA), (2) barbed suture anastomosis (B-HSA), (3) stapled functional end-to-end anastomosis (SFEEA), and (4) stapled functional end-to-end anastomosis with an oversew (SFEEA-O). Control segments and anastomotic constructs were infused intraluminally to the point of leakage. Initial leak pressures were recorded and compared. RESULTS Initial leak pressures (median + range) for jejunal control segments, HSA, B-HSA, SFEEA, and SFEEA-O were 331.88 mmHg (range, 315.34-346.64), 35.17 (20.29-56.24), 24.99 (6.08-38.64), 28.77 (18.80-85.09), and 35.92 (12.05-80.71), respectively. No difference was detected between leak pressures of anastomosed segments (P = .35), all of which were more variable and lower than those of intact segments. CONCLUSION No difference in initial leak pressures was detected between the four anastomosis techniques tested in cooled canine cadaveric jejunum. CLINICAL SIGNIFICANCE All four anastomosis techniques evaluated in this study may be suitable in dogs.
Collapse
Affiliation(s)
- Mark J Fealey
- Department of Small Animal Clinical Sciences, College of Veterinary Medicine, University of Florida, Gainesville, Florida
| | - Penny J Regier
- Department of Small Animal Clinical Sciences, College of Veterinary Medicine, University of Florida, Gainesville, Florida
| | - Charles Steadman Bs
- Department of Small Animal Clinical Sciences, College of Veterinary Medicine, University of Florida, Gainesville, Florida
| | - J Brad Case
- Department of Small Animal Clinical Sciences, College of Veterinary Medicine, University of Florida, Gainesville, Florida
| | - Fernando Garcia-Pereira
- Department of Small Animal Clinical Sciences, College of Veterinary Medicine, University of Florida, Gainesville, Florida
| |
Collapse
|
21
|
Duffy DJ, Chang YJ, Balko JA, Moore GE. Ex vivo comparison of the effect of storage temperature on canine intestinal leakage pressures. Vet Surg 2019; 49:496-501. [PMID: 31721267 DOI: 10.1111/vsu.13339] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2019] [Revised: 08/11/2019] [Accepted: 09/12/2019] [Indexed: 12/01/2022]
Abstract
OBJECTIVE To determine the effect of storage temperature on cadaveric small intestinal leakage pressures after enterotomy. STUDY DESIGN Experimental ex vivo study. ANIMALS Grossly normal jejunal segments from four canine cadavers. METHODS Thirty-six jejunal segments (n = 12 segments/group) were harvested immediately after euthanasia and assigned to a fresh group (tested within 4 hours), chilled group (stored for 24 hours at 4°C before testing), or freeze-thaw group (frozen at -20°C for 7 days and thawed at 21°C for 6 hours before testing). A 2-cm antimesenteric enterotomy was performed and repaired with 4-0 monofilament suture in a simple-continuous pattern. Initial leakage pressure (ILP), maximal intraluminal pressure (MIP), and leakage location were recorded, with testing performed at room temperature. RESULTS Mean ± SD ILP for fresh, chilled, and frozen-thawed specimens was 52.9 ± 8.4, 51.8 ± 11.9 and 29.8 ± 4.4 mm Hg, respectively. There was a difference in ILP among groups (P < .003), with freeze-thaw samples demonstrating lower ILP compared with other groups. There was no difference in MIP between groups (P = .186) There was a difference in leakage location among groups (P = .004), with the majority of chilled and freeze-thaw samples leaking at the suture holes compared with the incisional line in fresh samples. CONCLUSION Freezing and subsequent thawing prior to specimen testing reduced ILP compared with use of fresh and chilled specimens but did not affect MIP among experimental groups. CLINICAL SIGNIFICANCE Cadaveric canine intestinal specimens tested immediately after collection or after chilling for 24 hours should be recommended for ex vivo burst pressure assessment in dogs. Additional studies to evaluate loss in testing viability of chilled intestinal specimens are warranted to help govern experimental methodologies.
Collapse
Affiliation(s)
- Daniel J Duffy
- Department of Clinical Sciences, College of Veterinary Medicine, North Carolina State University, Raleigh, North Carolina
| | - Yi-Jen Chang
- Department of Clinical Sciences, College of Veterinary Medicine, North Carolina State University, Raleigh, North Carolina
| | - Julie A Balko
- Department of Molecular and Biomedical Sciences, College of Veterinary Medicine, North Carolina State University, Raleigh, North Carolina
| | - George E Moore
- Veterinary Administration, College of Veterinary Medicine, Purdue University, West Lafayette, Indiana
| |
Collapse
|
22
|
Frame K, Ben‐Amotz O, Simpler R, Zuckerman J, Ben‐Amotz R. The use of bidirectional barbed suture in the treatment of a complete common calcanean tendon rupture in a dog: Long-term clinical and ultrasonographic evaluation. Clin Case Rep 2019; 7:1565-1572. [PMID: 31428393 PMCID: PMC6692997 DOI: 10.1002/ccr3.2287] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2019] [Revised: 05/31/2019] [Accepted: 06/04/2019] [Indexed: 11/22/2022] Open
Abstract
The canine common calcanean tendon can be repaired successfully using a modified Kessler knotless barbed technique. A long-term ultrasound follow-up showed improved and increased normal tendon fibrillar echotexture and homogeneity.
Collapse
Affiliation(s)
- Kevin Frame
- Veterinary Specialty and Emergency CenterBluepearl Veterinary PartnersPhiladelphiaPennsylvania
| | - Oded Ben‐Amotz
- Rambam 80, Hand and Microsurgery UnitHealthcare CampusHaifaIsrael
| | - Renee Simpler
- Veterinary Specialty and Emergency CenterBluepearl Veterinary PartnersPhiladelphiaPennsylvania
| | - Josh Zuckerman
- Veterinary Specialty and Emergency CenterBluepearl Veterinary PartnersPhiladelphiaPennsylvania
- Cape Cod Veterinary SpecialistsBuzzards BayMassachusetts
| | - Ron Ben‐Amotz
- Veterinary Specialty and Emergency CenterBluepearl Veterinary PartnersPhiladelphiaPennsylvania
| |
Collapse
|
23
|
Brand KJ, Hess E, Risselada M. Effects of needle gauge and syringe size on small intestinal leakage at injection sites. Vet Surg 2019; 48:1237-1244. [PMID: 31286539 DOI: 10.1111/vsu.13278] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2018] [Revised: 05/08/2019] [Accepted: 06/09/2019] [Indexed: 02/05/2023]
Abstract
OBJECTIVE To determine the influence of needle gauge, syringe volume, and syringe size on needle tract leakage after injection in porcine jejunum. STUDY DESIGN Ex vivo experiment. SAMPLE POPULATION Three hundred sixty jejunal segments from 20 feedlot pigs. METHODS Fresh porcine intestines were divided into 5-cm or 10-cm segments and randomly assigned to the one of nine treatment groups: 25-gauge, 22-gauge, and 20-gauge needles attached to full 12-mL, half-full 20-mL, and full 20-mL syringes (n = 20/group). The jejunal segments were occluded with Rochester-Carmalt forceps prior to injection of diluted India ink. Injection time and leakage were noted by a blinded observer. Multivariate analysis was used with segment size, needle gauge, volume infused, time to inject per milliliter, and syringe size as variables. RESULTS Leakage occurred in 36% of 5-cm and 15% of 10-cm segments and was immediate without palpation in 33.8% and 11% of segments, respectively. Protective effects were seen for 22-gauge needles in both 5-cm (P = .002) and 10-cm (P = .001) segments, whereas injection of 20 mL had a higher odds ratio of leakage compared with injection of 10 mL and 12 mL in 5-cm segments (P = .003). CONCLUSION Injections with 22-gauge needles reduced the frequency of leakage, while 20 mL instilled in 5-cm segments increased the frequency of leakage in intact segments of porcine jejunum. CLINICAL SIGNIFICANCE Injection with a smaller syringe size attached to a 22-gauge needle through a 10-cm segment of small intestine may lower the frequency of leakage from the injection site, but influence on the detection of surgical site leakage remains unknown.
Collapse
Affiliation(s)
- Kenneth J Brand
- Purdue Veterinary Medicine, Department of Veterinary Clinical Sciences, West Lafayette, Indiana
| | - Emily Hess
- Purdue Veterinary Medicine, Department of Veterinary Clinical Sciences, West Lafayette, Indiana
| | - Marije Risselada
- Purdue Veterinary Medicine, Department of Veterinary Clinical Sciences, West Lafayette, Indiana
| |
Collapse
|
24
|
Giusto G, Iussich S, Tursi M, Perona G, Gandini M. Comparison of two different barbed suture materials for end-to-end jejuno-jejunal anastomosis in pigs. Acta Vet Scand 2019; 61:3. [PMID: 30611301 PMCID: PMC6321647 DOI: 10.1186/s13028-018-0437-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2017] [Accepted: 12/27/2018] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Hand-sewn intestinal anastomoses are a fundamental procedure in both open and laparoscopic intestinal surgery. Self-retaining barbed suture devices have been tested for a variety of surgical applications. With the exception of clinical reports and various experimental studies on enterotomy, little has been published so far on the use of barbed suture for end-to-end intestinal anastomoses. The aim of the study was to compare two different barbed suture materials for end-to-end jejuno-jejunal anastomosis in pigs. End-to-end jejuno-jejunal anastomosis were performed with unidirectional barbed (A group), bidirectional barbed (B group) or normal (C group) sutures in each animal. A comparison was then made between the groups based on adhesions scoring, suturing time, bursting pressure and histopathology. RESULTS Mean construction times in the A group (518 ± 40 s) and in the B group (487 ± 45 s) were significantly lower than in the C group (587 ± 63 s) but were not different between A and B group (P = 0.10). Mean bursting pressures were significantly higher in the intact intestine (197 ± 13 mmHg) than in any other group (group A 150 ± 16 mmHg, group B 145 ± 22 mmHg, group C 145 ± 24 mmHg). Among anastomotic techniques, the bursting pressures were not significantly different. Histologically no difference could be detected in the grade of inflammation, collagen deposition and neovascularization at the anastomotic sites. CONCLUSIONS Barbed sutures can be effectively used for handsewn end-to-end jejunojejunal anastomosis in pigs. They are comparable to normal suture but could provide a shorter surgical time.
Collapse
|
25
|
Bailey KL, Johnson M, Travers CJ, Fox-Alvarez WA. Biomechanical analysis of unidirectional knotless suture loop weld integrity after passage through a cadaveric body wall. Vet Surg 2018; 48:431-436. [PMID: 30370567 DOI: 10.1111/vsu.13122] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2018] [Revised: 09/23/2018] [Accepted: 09/24/2018] [Indexed: 11/30/2022]
Abstract
OBJECTIVE To evaluate the integrity of the welded end loop on unidirectional knotless suture after transabdominal passage in a canine cadaver. STUDY DESIGN Ex vivo biomechanical study. STUDY POPULATION Four variations of unidirectional knotless suture and 1 canine cadaver. METHODS Welded end loop on strands consisted of 0 Quill polydioxanone (QP; n = 22), 0 Quill monoderm (QM; n = 23), 2-0 V-Loc 90 (V9; n = 12), and 2-0 V-Loc 180 (V18; n = 12). Half of the suture strands in each group were passed percutaneously through an insufflated cadaveric body wall, and the remaining half served as intact controls. A linear testing machine was used to load the sutures to failure. Modes of and loads to failure were compared within and between suture types. RESULTS Loads to failure did not differ between sutures passed through the body wall and their controls when the loop remained intact. Sutures V9, V18, and QM sustained higher loads to failure compared with QP. All Quill suture lines failed at the weld during testing. Thirty-three percent of QP sutures failed at the weld during initial passage through the body wall. V-Loc sutures failed at the suture-apparatus interface, within the welded loop, or a combination. CONCLUSION Passing suture through a cadaveric body wall did not affect the integrity of the welded end loop of any of the unidirectional knotless sutures tested here when the loop remained intact. CLINICAL SIGNIFICANCE Unidirectional knotless suture (V9, V18 and QM) can be safely passed through a canine body wall for use in laparoscopic procedures. The use of QP in this manner cannot be recommended.
Collapse
Affiliation(s)
- Kristin L Bailey
- Department of Small Animal Clinical Sciences, College of Veterinary Medicine, University of Florida, Gainesville, Florida
| | - Matthew Johnson
- Department of Small Animal Clinical Sciences, College of Veterinary Medicine, University of Florida, Gainesville, Florida
| | - Colin J Travers
- College of Engineering, University of Florida, Gainesville, Florida
| | - W Alexander Fox-Alvarez
- Department of Small Animal Clinical Sciences, College of Veterinary Medicine, University of Florida, Gainesville, Florida
| |
Collapse
|
26
|
Aeschlimann KA, Mann FA, Middleton JR, Belter RC. Comparison of enterotomy leak pressure among fresh, cooled, and frozen-thawed porcine jejunal segments. Am J Vet Res 2018; 79:576-580. [DOI: 10.2460/ajvr.79.5.576] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
27
|
Kieves NR, Krebs AI, Zellner EM. A Comparison of Ex Vivo Leak Pressures for Four Enterotomy Closures in a Canine Model. J Am Anim Hosp Assoc 2018; 54:71-76. [DOI: 10.5326/jaaha-ms-6459] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
ABSTRACT
Initial and maximum intraluminal leak pressures of four enterotomy closures were compared. Closure patterns included a modified Gambee, simple interrupted, simple continuous, and skin staple closure. Forty-eight 3-cm enterotomy constructs were created from jejunal segments harvested from 12 dogs. Twelve each were randomly assigned to the four closure methods. Time of closure, as well as initial and maximum leak pressures, were measured and compared. The modified Gambee closure was the slowest closure to perform, with skin staple closure being the fastest. All suture patterns tested had higher mean initial leak pressures than reported physiologic intestinal pressures during peristalsis, although the skin staple closures resulted in leakage below normal physiologic pressure in several samples. The modified Gambee closure was able to sustain a significantly higher initial leak pressure than skin staple closures. The modified Gambee suture pattern had the greatest maximum leak pressure of all enterotomy closure patterns tested. Use of the modified Gambee suture pattern should be considered in enterotomy closure, although in vivo studies are required to determine if these differences are clinically significant.
Collapse
Affiliation(s)
- Nina R. Kieves
- From the Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Iowa State University, Ames, Iowa
| | - Alexander I. Krebs
- From the Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Iowa State University, Ames, Iowa
| | - Eric M. Zellner
- From the Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Iowa State University, Ames, Iowa
| |
Collapse
|
28
|
Ex vivo biomechanical comparison of barbed suture and standard polypropylene suture for acute tendon laceration in a canine model. Vet Comp Orthop Traumatol 2017; 28:263-9. [DOI: 10.3415/vcot-14-11-0174] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2014] [Accepted: 04/27/2015] [Indexed: 11/17/2022]
Abstract
SummaryObjectives: Evaluate performance and resistance to gap formation of a non-absorbable, barbed, monofilament suture, in comparison with a non-absorbable, smooth, monofilament polypropylene suture, in two different suture patterns: three-loop pulley (3LP) and modified Bunnell-Mayer (BM).Sample size: Seventy-two medium-sized cadaveric superficial digital flexor muscle tendon units.Methods: After manual transection and suture repair, individual specimens were placed in an electromechanical tensile testing machine and tested to monotonic failure using tensile ramp loading. Video data acquisition allowed evaluation of failure mode and quantification of gap formation.Results: Incidence of gap formation between tendon ends was significantly greater in tenorrhaphies repaired with barbed suture compared to those repaired with smooth polypropylene. Use of a 3LP suture pattern caused significantly less gapping between tendon ends when compared to the BM pattern.Conclusion: Smooth polypropylene suture was consistently superior in load performance than a unidirectional barbed suture. The 3LP pattern was more resistant than a BM pattern at preventing gap formation.Clinical significance: Smooth polypropylene should be recommended over barbed unidirectional suture for use in canine tendinous repair to provide increased resistance to gap formation. The 3LP is superior to the BM suture pattern, requiring significantly more force to cause tenorrhaphy gap formation and failure, which may translate to increased accrual of repair site strength and tendinous healing in clinical situations.
Collapse
|
29
|
Jones CT, Chen CY, Campbell BG, Fransson BA. Assessment of leakage pressure following enterotomy closure reinforced by tissue adhesive in a caprine cadaver model. N Z Vet J 2017. [DOI: 10.1080/00480169.2017.1344586] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
Affiliation(s)
- CT Jones
- Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Washington State University, Pullman, WA 99164-6610, USA
| | - CY Chen
- Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Washington State University, Pullman, WA 99164-6610, USA
- Atlantic Veterinary College, University of Prince Edward Island, 550 University Avenue, Charlottetown, Prince Edward Island, Canada C1A 4P3
| | - BG Campbell
- Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Washington State University, Pullman, WA 99164-6610, USA
| | - BA Fransson
- Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Washington State University, Pullman, WA 99164-6610, USA
| |
Collapse
|
30
|
Montel JS, Duffy DJ, Weng HY, Freeman LJ. Single layer cystotomy closure of excised porcine bladders with barbed versus smooth suture material. Vet Surg 2017; 46:580-586. [PMID: 28463428 DOI: 10.1111/vsu.12644] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2016] [Accepted: 11/23/2016] [Indexed: 11/29/2022]
Affiliation(s)
- Joshua S. Montel
- Department of Veterinary Clinical Sciences and Comparative Pathobiology; Purdue University Veterinary Teaching Hospital; West Lafayette Indiana
| | - Daniel J. Duffy
- Department of Veterinary Clinical Sciences and Comparative Pathobiology; Purdue University Veterinary Teaching Hospital; West Lafayette Indiana
| | - Hsin-Yi Weng
- Department of Veterinary Clinical Sciences and Comparative Pathobiology; Purdue University Veterinary Teaching Hospital; West Lafayette Indiana
| | - Lynetta J. Freeman
- Department of Veterinary Clinical Sciences and Comparative Pathobiology; Purdue University Veterinary Teaching Hospital; West Lafayette Indiana
| |
Collapse
|
31
|
Gandini M, Nannarone S, Giusto G, Pepe M, Comino F, Caramello V, Gialletti R. Laparoscopic nephrosplenic space ablation with barbed suture in eight horses. J Am Vet Med Assoc 2017; 250:431-436. [DOI: 10.2460/javma.250.4.431] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
32
|
Shimizu N, Tarlton J, Friend E, Doran I, Parsons K. Tensile Comparison of Polydioxanone, Polyglyconate, and Barbed Glycolide-Trimethylene Carbonate Suture in Canine Cadaveric Tensor Fascia Lata. Vet Surg 2016; 46:89-94. [DOI: 10.1111/vsu.12580] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2015] [Accepted: 08/15/2016] [Indexed: 12/12/2022]
Affiliation(s)
- Naomi Shimizu
- Department of Clinical Sciences (Companion Animals), College of Veterinary Medicine; University of Liège; Liège Belgium
| | - John Tarlton
- School of Veterinary Sciences; University of Bristol; Bristol United Kingdom
| | - Ed Friend
- School of Veterinary Sciences; University of Bristol; Bristol United Kingdom
| | - Ivan Doran
- School of Veterinary Sciences; University of Bristol; Bristol United Kingdom
| | - Kevin Parsons
- School of Veterinary Sciences; University of Bristol; Bristol United Kingdom
| |
Collapse
|
33
|
Law AY, Butler JR, Patnaik SS, Cooley JA, Elder SH. Biomechanical Testing and Histologic Examination of Intradermal Skin Closure in Dogs Using Barbed Suture Device and Non-Barbed Monofilament Suture. Vet Surg 2016; 46:59-66. [DOI: 10.1111/vsu.12576] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2015] [Accepted: 07/27/2016] [Indexed: 11/29/2022]
Affiliation(s)
- Andy Y. Law
- Department of Clinical Sciences, College of Veterinary Medicine; Mississippi State University; Mississippi State, Mississippi
| | - James R. Butler
- Department of Clinical Sciences, College of Veterinary Medicine; Mississippi State University; Mississippi State, Mississippi
| | - Sourav S. Patnaik
- Department of Agricultural and Biological Engineering, Bagley College of Engineering; Mississippi State University; Mississippi State, Mississippi
| | - James A. Cooley
- Department of Pathobiology and Population Medicine, College of Veterinary Medicine; Mississippi State University; Mississippi State, Mississippi
| | - Steven H. Elder
- Department of Agricultural and Biological Engineering, Bagley College of Engineering; Mississippi State University; Mississippi State, Mississippi
| |
Collapse
|
34
|
Albanese V, Hanson RR, McMaster MA, Koehler JW, Caldwell FJ. Use of a Barbed Knotless Suture for Laparoscopic Ablation of the Nephrosplenic Space in 8 Horses. Vet Surg 2016; 45:824-30. [DOI: 10.1111/vsu.12520] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2015] [Accepted: 04/25/2016] [Indexed: 11/30/2022]
Affiliation(s)
- Valeria Albanese
- Department of Clinical Sciences; JT Vaughan Large Animal Teaching Hospital; Auburn Alabama
| | - R. Reid Hanson
- Department of Clinical Sciences; JT Vaughan Large Animal Teaching Hospital; Auburn Alabama
| | - Mattie A. McMaster
- Department of Clinical Sciences; JT Vaughan Large Animal Teaching Hospital; Auburn Alabama
| | - Jennifer W. Koehler
- Department of Pathobiology, College of Veterinary Medicine; Auburn University; Auburn Alabama
| | - Fred J. Caldwell
- Department of Clinical Sciences; JT Vaughan Large Animal Teaching Hospital; Auburn Alabama
| |
Collapse
|
35
|
Hansen LA, Smeak DD. In vitro comparison of leakage pressure and leakage location for various staple line offset configurations in functional end-to-end stapled small intestinal anastomoses of canine tissues. Am J Vet Res 2015; 76:644-8. [DOI: 10.2460/ajvr.76.7.644] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
36
|
Alvarez WA, Scharf VF, Case JB. Comparison of Laparoscopic and Open Cystopexy in a Cadaveric Canine Model. Vet Surg 2015; 44 Suppl 1:44-9. [DOI: 10.1111/j.1532-950x.2014.12284.x] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2013] [Accepted: 05/01/2014] [Indexed: 11/27/2022]
Affiliation(s)
- W. Alexander Alvarez
- Department of Small Animal Clinical Sciences; College of Veterinary Medicine, University of Florida; Gainesville Florida
| | - Valery F. Scharf
- Department of Small Animal Clinical Sciences; College of Veterinary Medicine, University of Florida; Gainesville Florida
| | - J. Brad Case
- Department of Small Animal Clinical Sciences; College of Veterinary Medicine, University of Florida; Gainesville Florida
| |
Collapse
|
37
|
Hansen LA, Monnet EL. Evaluation of serosal patch supplementation of surgical anastomoses in intestinal segments from canine cadavers. Am J Vet Res 2013; 74:1138-41. [DOI: 10.2460/ajvr.74.8.1138] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|