Yao F, Li J, Huang M, Gao X, Zhang Y. Comparison of computed versus acquired readout-segmented diffusion-weighted imaging in visualizing scrotal or testicular lesions. Clin Radiol 2024:S0009-9260(24)00396-9. [PMID: 39122632 DOI: 10.1016/j.crad.2024.07.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2024] [Revised: 06/26/2024] [Accepted: 07/15/2024] [Indexed: 08/12/2024]
Abstract
PURPOSE Combining computed diffusion-weighted imaging (DWI) with readout-segmented echo-planar-imaging may shorten acquisition time and improve imaging quality. This study aimed to compare computed vs. acquired DWI qualitatively and quantitatively in visualizing scrotal or testicular lesions. MATERIALS AND METHODS We retrospectively enrolled 57 consecutive men who underwent scrotal MRI. Four computed DWI sets (cDWI800, cDWI1000, cDWI1200, and cDWI1400) were generated from acquired DWI with two lower b-values (150 and 600 s/mm2). Acquired DWI (DWI800 and DWI1000) and computed DWI were compared through qualitative (susceptibility artifact, signal loss artifact, anatomic clarity, and lesion conspicuity) and quantitative assessment (signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and lesion-to-testicular parenchyma contrast ratio (CR)). RESULTS Computed DWI was prone to signal loss artifact and slightly lower assessment scores in terms of anatomic clarity and lesion conspicuity, comparing with acquired DWI. The SNR of computed and acquired DWI decreased with increasing b value. Under the same b-values (800 and 1,000 s/mm2), there was no difference in the median SNR and CR between computed and acquired DWI. The median CR of cDWI1400 was significantly higher than that of the other DWI sets excepting cDWI1200 (P=1.000). The median CNR tended to be lower for computed vs. acquired DWI, while no significant difference (P=0.233). CONCLUSIONS Computed and acquired DWI were nearly equivalent in both qualitative and quantitative evaluations at the b values of 800 and 1,000 s/mm2. Computed DWI could enhance the contrast of scrotal or testicular lesions.
Collapse
Affiliation(s)
- F Yao
- Department of MRI, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan Province 450052, China.
| | - J Li
- Department of MRI, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan Province 450052, China
| | - M Huang
- Department of MRI, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan Province 450052, China
| | - X Gao
- Department of MRI, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan Province 450052, China
| | - Y Zhang
- Department of MRI, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan Province 450052, China
| |
Collapse
|
2
|
Kazama T, Takahara T, Endo J, Yamamuro H, Sekiguchi T, Niwa T, Niikura N, Okamura T, Kumaki N, Hashimoto J. Computed diffusion-weighted imaging with a low-apparent diffusion coefficient-pixel cut-off technique for breast cancer detection. Br J Radiol 2023; 96:20220951. [PMID: 37393536 PMCID: PMC10607411 DOI: 10.1259/bjr.20220951] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2022] [Revised: 06/15/2023] [Accepted: 06/24/2023] [Indexed: 07/03/2023] Open
Abstract
OBJECTIVE This study aimed to compare the image quality and diagnostic performance of computed diffusion-weighted imaging (DWI) with low-apparent diffusion coefficient (ADC)-pixel cut-off technique (cDWI cut-off) and actual measured DWI (mDWI). METHODS Eighty-seven consecutive patients with malignant breast lesions and 72 with negative breast lesions who underwent breast MRI were retrospectively evaluated. Computed DWI with high b-values of 800, 1200, and 1500 s/mm2 and ADC cut-off thresholds of none, 0, 0.3, and 0.6 (×10-3 mm2/s) were generated from DWI with two b-values (0 and 800 s/mm2). To identify the optimal conditions, two radiologists evaluated the fat suppression and lesion reduction failure using a cut-off technique. The contrast between breast cancer and glandular tissue was evaluated using region of interest analysis. Three other board-certified radiologists independently assessed the optimised cDWI cut-off and mDWI data sets. Diagnostic performance was evaluated using receiver operating characteristic (ROC) analysis. RESULTS When an ADC cut-off threshold of 0.3 or 0.6 (× 10-3 mm2/s) was applied, fat suppression improved significantly (p < .05). The contrast of the cDWI cut-off with a b-value of 1200 or 1500 s/mm2 was better than the mDWI (p < .01). The ROC area under the curve for breast cancer detection was 0.837 for the mDWI and 0.909 for the cDWI cut-off (p < .01). CONCLUSION The cDWI cut-off provided better diagnostic performance than mDWI for breast cancer detection. ADVANCES IN KNOWLEDGE Using the low-ADC-pixel cut-off technique, computed DWI can improve diagnostic performance by increasing contrast and eliminating un-suppressed fat signals.
Collapse
Affiliation(s)
- Toshiki Kazama
- Department of Diagnostic Radiology, Tokai University School of Medicine, Isehara, Japan
| | - Taro Takahara
- Department of Biomedical Engineering, Tokai University School of Engineering, Hiratsuka, Japan
| | - Jun Endo
- Department of Diagnostic Radiology, Tokai University School of Medicine, Isehara, Japan
| | - Hiroshi Yamamuro
- Department of Diagnostic Radiology, Tokai University School of Medicine, Isehara, Japan
| | - Tatsuya Sekiguchi
- Department of Diagnostic Radiology, Tokai University School of Medicine, Isehara, Japan
| | - Tetsu Niwa
- Department of Diagnostic Radiology, Tokai University School of Medicine, Isehara, Japan
| | - Naoki Niikura
- Department of Breast Oncology, Tokai University School of Medicine, Isehara, Japan
| | - Takuho Okamura
- Department of Breast Oncology, Tokai University School of Medicine, Isehara, Japan
| | - Nobue Kumaki
- Department of Pathology, Tokai University School of Medicine, Isehara, Japan
| | - Jun Hashimoto
- Department of Diagnostic Radiology, Tokai University School of Medicine, Isehara, Japan
| |
Collapse
|
3
|
Harder FN, Jung E, Weiss K, Graf MM, Kamal O, McTavish S, Van AT, Demir IE, Friess H, Phillip V, Schmid RM, Lohöfer FK, Kaissis GA, Makowski MR, Karampinos DC, Braren RF. Computed high-b-value high-resolution DWI improves solid lesion detection in IPMN of the pancreas. Eur Radiol 2023; 33:6892-6901. [PMID: 37133518 PMCID: PMC10511579 DOI: 10.1007/s00330-023-09661-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2022] [Revised: 02/15/2023] [Accepted: 02/26/2023] [Indexed: 05/04/2023]
Abstract
OBJECTIVES To examine the effect of high-b-value computed diffusion-weighted imaging (cDWI) on solid lesion detection and classification in pancreatic intraductal papillary mucinous neoplasm (IPMN), using endoscopic ultrasound (EUS) and histopathology as a standard of reference. METHODS Eighty-two patients with known or suspected IPMN were retrospectively enrolled. Computed high-b-value images at b = 1000 s/mm2 were calculated from standard (b = 0, 50, 300, and 600 s/mm2) DWI images for conventional full field-of-view (fFOV, 3 × 3 × 4 mm3 voxel size) DWI. A subset of 39 patients received additional high-resolution reduced-field-of-view (rFOV, 2.5 × 2.5 × 3 mm3 voxel size) DWI. In this cohort, rFOV cDWI was compared against fFOV cDWI additionally. Two experienced radiologists evaluated (Likert scale 1-4) image quality (overall image quality, lesion detection and delineation, fluid suppression within the lesion). In addition, quantitative image parameters (apparent signal-to-noise ratio (aSNR), apparent contrast-to-noise ratio (aCNR), contrast ratio (CR)) were assessed. Diagnostic confidence regarding the presence/absence of diffusion-restricted solid nodules was assessed in an additional reader study. RESULTS High-b-value cDWI at b = 1000 s/mm2 outperformed acquired DWI at b = 600 s/mm2 regarding lesion detection, fluid suppression, aCNR, CR, and lesion classification (p = < .001-.002). Comparing cDWI from fFOV and rFOV revealed higher image quality in high-resolution rFOV-DWI compared to conventional fFOV-DWI (p ≤ .001-.018). High-b-value cDWI images were rated non-inferior to directly acquired high-b-value DWI images (p = .095-.655). CONCLUSIONS High-b-value cDWI may improve the detection and classification of solid lesions in IPMN. Combining high-resolution imaging and high-b-value cDWI may further increase diagnostic precision. CLINICAL RELEVANCE STATEMENT This study shows the potential of computed high-resolution high-sensitivity diffusion-weighted magnetic resonance imaging for solid lesion detection in pancreatic intraductal papillary mucinous neoplasia (IPMN). The technique may enable early cancer detection in patients under surveillance. KEY POINTS • Computed high-b-value diffusion-weighted imaging (cDWI) may improve the detection and classification of intraductal papillary mucinous neoplasms (IPMN) of the pancreas. • cDWI calculated from high-resolution imaging increases diagnostic precision compared to cDWI calculated from conventional-resolution imaging. • cDWI has the potential to strengthen the role of MRI for screening and surveillance of IPMN, particularly in view of the rising incidence of IPMNs combined with now more conservative therapeutic approaches.
Collapse
Affiliation(s)
- Felix N Harder
- Institute of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine, Munich, Germany.
| | - Eva Jung
- Institute of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine, Munich, Germany
| | - Kilian Weiss
- Philips GmbH Market DACH, Röntgenstrasse 22, 22335, Hamburg, Germany
| | - Markus M Graf
- Institute of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine, Munich, Germany
| | - Omar Kamal
- Institute of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine, Munich, Germany
| | - Sean McTavish
- Institute of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine, Munich, Germany
| | - Anh T Van
- Institute of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine, Munich, Germany
| | - Ihsan E Demir
- Department of Surgery, Klinikum Rechts Der Isar, School of Medicine, Technical University of Munich, Munich, Germany
| | - Helmut Friess
- Department of Medicine II, University Hospital Rechts Der Isar, Technical University Munich, Munich, Germany
| | - Veit Phillip
- Department of Medicine II, University Hospital Rechts Der Isar, Technical University Munich, Munich, Germany
| | - Roland M Schmid
- Department of Medicine II, University Hospital Rechts Der Isar, Technical University Munich, Munich, Germany
| | - Fabian K Lohöfer
- Institute of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine, Munich, Germany
| | - Georgios A Kaissis
- Institute of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine, Munich, Germany
- Department of Computing, Faculty of Engineering, Imperial College of Science, Technology and Medicine, London, SW7 2AZ, UK
- Institute for Artificial Intelligence in Medicine, Technical University of Munich, Munich, Germany
| | - Marcus R Makowski
- Institute of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine, Munich, Germany
| | - Dimitrios C Karampinos
- Institute of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine, Munich, Germany
- Munich Institute of Biomedical Engineering, Technical University of Munich, Garching, Germany
| | - Rickmer F Braren
- Institute of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine, Munich, Germany.
| |
Collapse
|
4
|
Shin HJ, Son NH, Hwang SH, Song K. Reliability of synthetic diffusion-weighted imaging with a high b-value for paediatric abdominal MRI. Clin Radiol 2023; 78:616-621. [PMID: 37149417 DOI: 10.1016/j.crad.2023.04.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2022] [Revised: 03/01/2023] [Accepted: 04/10/2023] [Indexed: 05/08/2023]
Abstract
AIM To evaluate the reliability of synthetic diffusion-weighted imaging (DWI) using a high b-value in comparison to conventional DWI for paediatric abdominal MRI. MATERIALS AND METHODS Paediatric patients (<19 years old) who underwent liver or pancreatobiliary MRI with DWI using 10 b-values (b = 0, 25, 50, 75, 100, 200, 400, 600, 800, 1,500 s/mm2) from March to October 2021 were included in this retrospective study. Using the software, synthetic DWI using b = 1,500 s/mm2 was generated automatically by selecting the b-value required as output. Conventional and synthetic DWI values for b = 1,500 s/mm2 were measured at the liver, spleen, paraspinal muscle, and mass lesions, if present, and apparent diffusion coefficient (ADC) values were calculated using the mono-exponential model. Intraclass correlation coefficients (ICCs) were calculated to assess the reliability of conventional and synthetic DWI and ADC values with b = 1,500 s/mm2. RESULTS Thirty paediatric patients (M:F = 22:8, mean 10.8 ± 3.1 years old) were included and four had tumours on abdominal MRI. ICC values were 0.906-0.995 between conventional and synthetic DWI and ADC with b = 1,500 s/mm2 in the liver, spleen and muscle. For mass lesions, ICC values were 0.997-0.999 for both synthetic DWI and ADC images. CONCLUSIONS Synthetic DWI and ADC values obtained using a high b-value showed excellent agreement with conventional DWI for the liver, spleen, muscle, and mass in paediatric MRI.
Collapse
Affiliation(s)
- H J Shin
- Department of Radiology, Research Institute of Radiological Science and Center for Clinical Imaging Data Science, Yongin Severance Hospital, Yonsei University College of Medicine, 363, Dongbaekjukjeon-daero, Giheung-gu, Yongin-si, Gyeonggi-do, 16995, Republic of Korea.
| | - N-H Son
- Department of Statistics, Keimyung University, 1095 Dalgubeol-daero, Dalseo-gu, Daegu, 42601, Republic of Korea
| | - S H Hwang
- Department of Radiology, Research Institute of Radiological Science and Center for Clinical Imaging Data Science, Yongin Severance Hospital, Yonsei University College of Medicine, 363, Dongbaekjukjeon-daero, Giheung-gu, Yongin-si, Gyeonggi-do, 16995, Republic of Korea
| | - K Song
- Department of Paediatrics, Division of Paediatric Endocrinology, Yonsei University College of Medicine, 363, Dongbaekjukjeon-daero, Giheung-gu, Yongin-si, Gyeonggi-do, 16995, Republic of Korea
| |
Collapse
|
5
|
High-Resolution, High b-Value Computed Diffusion-Weighted Imaging Improves Detection of Pancreatic Ductal Adenocarcinoma. Cancers (Basel) 2022; 14:cancers14030470. [PMID: 35158737 PMCID: PMC8833466 DOI: 10.3390/cancers14030470] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2021] [Accepted: 01/13/2022] [Indexed: 02/04/2023] Open
Abstract
Background: Our purpose was to investigate the potential of high-resolution, high b-value computed DWI (cDWI) in pancreatic ductal adenocarcinoma (PDAC) detection. Materials and Methods: We retrospectively enrolled 44 patients with confirmed PDAC. Respiratory-triggered, diffusion-weighted, single-shot echo-planar imaging (ss-EPI) with both conventional (i.e., full field-of-view, 3 × 3 × 4 mm voxel size, b = 0, 50, 300, 600 s/mm2) and high-resolution (i.e., reduced field-of-view, 2.5 × 2.5 × 3 mm voxel size, b = 0, 50, 300, 600, 1000 s/mm2) imaging was performed for suspected PDAC. cDWI datasets at b = 1000 s/mm2 were generated for the conventional and high-resolution datasets. Three radiologists were asked to subjectively rate (on a Likert scale of 1–4) the following metrics: image quality, lesion detection and delineation, and lesion-to-pancreas intensity relation. Furthermore, the following quantitative image parameters were assessed: apparent signal-to-noise ratio (aSNR), contrast-to-noise ratio (aCNR), and lesion-to-pancreas contrast ratio (CR). Results: High-resolution, high b-value computed DWI (r-cDWI1000) enabled significant improvement in lesion detection and a higher incidence of a high lesion-to-pancreas intensity relation (type 1, clear hyperintense) compared to conventional high b-value computed and high-resolution high b-value acquired DWI (f-cDWI1000 and r-aDWI1000, respectively). Image quality was rated inferior in the r-cDWI1000 datasets compared to r-aDWI1000. Furthermore, the aCNR and CR were higher in the r-cDWI1000 datasets than in f-cDWI1000 and r-aDWI1000. Conclusion: High-resolution, high b-value computed DWI provides significantly better visualization of PDAC compared to the conventional high b-value computed and high-resolution high b-value images acquired by DWI.
Collapse
|
6
|
Matsuura K, Inoue K, Hoshino E, Yasuda M, Hasegawa K, Okada Y, Baba Y, Kozawa E. Utility of magnetic resonance imaging for differentiating malignant mesenchymal tumors of the uterus from T2-weighted hyperintense leiomyomas. Jpn J Radiol 2021; 40:385-395. [PMID: 34750737 PMCID: PMC8977266 DOI: 10.1007/s11604-021-01217-2] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2021] [Accepted: 10/28/2021] [Indexed: 02/07/2023]
Abstract
PURPOSE To generate a new discrimination method to distinguish between malignant mesenchymal tumors of the uterus and T2-weighted hyperintense leiomyoma based on magnetic resonance imaging findings and clinical features. MATERIALS AND METHODS Data from 32 tumors of 32 patients with malignant mesenchymal tumors of the uterus and from 34 tumors of 30 patients with T2-weighted hyperintense leiomyoma were analyzed. Clinical parameters, qualitative magnetic resonance imaging features, including computed diffusion-weighted imaging, and quantitative characteristics of magnetic resonance imaging of these two tumor types were compared. Predictive values for malignant mesenchymal tumors of the uterus were calculated using variant discriminant analysis. RESULTS The T1 bright area on qualitative assessment and mean apparent diffusion coefficient value on quantitative assessment yielded the most independent magnetic resonance imaging differentiators of malignant mesenchymal tumors of the uterus and T2-weighted hyperintense leiomyoma. The classification accuracy of the variant discriminant analysis based on three selected findings, i.e., a T1 bright area, computed diffusion-weighted imaging with a b-value of 2000s/mm2 (cDWI2000), and T2-hypointense bands, was 84.8% (56/66), indicating high accuracy. CONCLUSIONS Variant discriminant analysis using the T1 bright area, cDWI2000, and T2-hypointense bands yielded high accuracy for differentiating between malignant mesenchymal tumors of the uterus and T2-weighted hyperintense leiomyoma.
Collapse
Affiliation(s)
- Koichiro Matsuura
- Department of Radiology, Saitama Medical University, 38, Morohongo, Moroyamamachi, Saitama, Japan.
| | - Kaiji Inoue
- Department of Radiology, Saitama Medical University, 38, Morohongo, Moroyamamachi, Saitama, Japan
| | - Eri Hoshino
- Department of Radiology, Saitama Medical University, 38, Morohongo, Moroyamamachi, Saitama, Japan
| | - Masanori Yasuda
- Department of Pathology, Saitama Medical University, 38, Morohongo, Moroyamamachi, Saitama, Japan
| | - Kosei Hasegawa
- Department of Gynecologic Oncology, Saitama Medical University, 38, Morohongo, Moroyamamachi, Saitama, Japan
| | - Yoshitaka Okada
- Department of Diagnostic Radiology, Saitama Medical University International Medical Center, 1397-1 Yamane, Hidaka, Saitama, Japan
| | - Yasutaka Baba
- Department of Diagnostic Radiology, Saitama Medical University International Medical Center, 1397-1 Yamane, Hidaka, Saitama, Japan
| | - Eito Kozawa
- Department of Radiology, Saitama Medical University, 38, Morohongo, Moroyamamachi, Saitama, Japan
| |
Collapse
|
7
|
DelPriore MR, Biswas D, Hippe DS, Zecevic M, Parsian S, Scheel JR, Rahbar H, Partridge SC. Breast Cancer Conspicuity on Computed Versus Acquired High b-Value Diffusion-Weighted MRI. Acad Radiol 2021; 28:1108-1117. [PMID: 32307271 DOI: 10.1016/j.acra.2020.03.011] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2020] [Revised: 03/07/2020] [Accepted: 03/08/2020] [Indexed: 12/30/2022]
Abstract
RATIONALE AND OBJECTIVES On unenhanced diffusion-weighted imaging (DWI), computing or synthesizing high b-value images from lower b-value acquisitions can enhance breast cancer visibility. This study aimed to evaluate relative lesion conspicuity on computed versus acquired diffusion-weighted images and investigate clinical characteristics influencing optimal b-values. MATERIALS AND METHODS Women with newly diagnosed breast cancer were prospectively enrolled and underwent 3T breast MRI with DWI. Lesion contrast-to-noise ratio (CNR) was measured across a range of b-values (0-2500 s/mm2) for computed and acquired DWI. Three readers independently compared lesion visibility between computed and acquired DWI and selected the optimal b-value. Computed versus acquired DWI was compared quantitatively based on CNR by paired t-test and qualitatively based on reader preference using a sign test. Optimal b-values by qualitative and quantitative assessment were compared by paired t-test, and associations with clinical characteristics were assessed by Wilcoxon rank sum test. RESULTS The study included 30 women (median age, 48 years); 28 with invasive carcinoma, 2 DCIS. Lesion CNR was higher on acquired versus computed images (p = 0.018), while lesion visibility by reader assessment was not different (p = 0.36). Optimal b-values selected by readers (mean, b = 1411 ± 383 s/mm2) were slightly higher than those based on peak CNR (b = 1233 ± 463 s/mm2, p = 0.023), and were higher for younger (≤50 years) versus older women (p = 0.002) and dense versus nondense breasts (p = 0.015). CONCLUSION Lesion CNR on computed high b-value images was slightly reduced versus acquired images, but our study suggests that this did not significantly impact lesion visibility. Computing high b-value images offers extra flexibility to adjust b-value during interpretation.
Collapse
|
8
|
Ahn HS, Kim SH, Kim JY, Park CS, Grimm R, Son Y. Image quality and diagnostic value of diffusion-weighted breast magnetic resonance imaging: Comparison of acquired and computed images. PLoS One 2021; 16:e0247379. [PMID: 33617567 PMCID: PMC7899336 DOI: 10.1371/journal.pone.0247379] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2020] [Accepted: 02/06/2021] [Indexed: 11/18/2022] Open
Abstract
PURPOSE To compare the image quality of acquired diffusion-weighted imaging (DWI) and computed DWI and evaluate the lesion detectability and likelihood of malignancy in these datasets. MATERIALS AND METHODS This prospective study was approved by our institutional review board. A total of 29 women (mean age, 43.5 years) underwent DWI between August 2018 and April 2019 for 32 breast cancers and 16 benign breast lesions. Three radiologists independently reviewed the acquired DWI with b-values of 1000 and 2000 s/mm2 (A-b1000 and A-b2000) and the computed DWI with a b-value of 2000 s/mm2 (C-b2000). Image quality was scored and compared between the three DWI datasets. Lesion detectability was recorded, and the lesion's likelihood for malignancy was scored using a five-point scale. RESULTS The A-b1000 images were superior to the A-b2000 and C-b2000 images in chest distinction, fat suppression, and overall image quality. The A-b2000 and C-b2000 images showed comparable scores for all image quality parameters. C-b2000 showed the highest values for lesion detection among all readers, although there was no statistical difference in sensitivity, specificity, positive predictive value, negative predictive value, and accuracy between the DWI datasets. The malignancy scores of the DWI images were not significantly different among the three readers. CONCLUSIONS A-b1000 DWI is suitable for breast lesion evaluations, considering its better image quality and comparable diagnostic values compared to that of A-b2000 and C-b2000 images. The additional use of computed high b-value DWI may have the potential to increase the detectability of breast masses.
Collapse
Affiliation(s)
- Hye Shin Ahn
- Department of Radiology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul, Republic of Korea
| | - Sung Hun Kim
- Department of Radiology, College of Medicine, Seoul St. Mary’s Hospital, The Catholic University of Korea, Seoul, Republic of Korea
- * E-mail:
| | - Ji Youn Kim
- Department of Radiology, College of Medicine, Yeouido St. Mary’s Hospital, The Catholic University of Korea, Seoul, Republic of Korea
| | - Chang Suk Park
- Department of Radiology, College of Medicine, Incheon St. Mary’s Hospital, The Catholic University of Korea, Icheon, Republic of Korea
| | - Robert Grimm
- MR Applications Development, Siemens Healthcare, Erlangen, Germany
| | - Yohan Son
- Siemens Healthineers Ltd., Seoul, Republic of Korea
| |
Collapse
|
9
|
Ichikawa S, Kromrey ML, Motosugi U, Onishi H. Optimal target b-value on computed diffusion-weighted magnetic resonance imaging for visualization of pancreatic ductal adenocarcinoma and focal autoimmune pancreatitis. Abdom Radiol (NY) 2021; 46:636-646. [PMID: 32740865 DOI: 10.1007/s00261-020-02695-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2020] [Revised: 07/21/2020] [Accepted: 07/25/2020] [Indexed: 12/26/2022]
Abstract
PURPOSE To compare computed diffusion-weighted imaging (cDWI) feasibility with that of directly acquired DWI for visualizing pancreatic ductal adenocarcinoma (PDAC) and focal autoimmune pancreatitis (AIP). METHODS From April 2012 to January 2017, 135 patients with PDAC (n = 111) or focal AIP (n = 24) were retrospectively enrolled. They underwent DWI with b-values of 0, 500, and 1000 s/mm2. From DWI0 and DWI1000, we generated cDWIs with targeted b-values of 1500, 2000, and 3000 s/mm2. The lesions' signal intensities, image quality, signal intensity ratio (SIR) of lesions and pancreatic parenchyma to spinal cord, and lesion-to-pancreatic parenchyma contrast ratio (CR) were compared among the five DWI protocols (DWI500, DWI1000, cDWI1500, cDWI2000, and cDWI3000). SIR was analyzed by receiver operating characteristic (ROC) analyses. RESULTS DWI500, DWI1000, and cDWI1500 had higher image quality than cDWI2000 and cDWI3000 (P < 0.001). The incidence of clear hyperintense PDAC was highest on cDWI2000, followed by cDWI1500, and cDWI3000 (P < 0.001-0.002), while the incidence of clear hyperintense AIP was higher on DWI1000, cDWI1500, and cDWI2000 than on DWI500 and cDWI3000 (P = 0.001-0.022). SIRs decreased whereas CRs increased as the b-value increased, for both PDAC and AIP. The area under the ROC curve (AUC) of SIRlesion was significantly lower on cDWI1500 than on cDWI2000 and cDWI3000 (P < 0.001). CONCLUSION cDWI1500 or cDWI2000 generated from b-values of 0 and 1000 s/mm2 were the most effective for visualizing PDAC and focal AIP; however, the SIRlesion AUC was significantly lower on cDWI1500 than on cDWI2000 and cDWI3000.
Collapse
Affiliation(s)
- Shintaro Ichikawa
- Department of Radiology, University of Yamanashi, 1110 Shimokato, Chuo-shi, 409-3898, Yamanashi, Japan.
| | - Marie-Luise Kromrey
- Department of Radiology, University of Yamanashi, 1110 Shimokato, Chuo-shi, 409-3898, Yamanashi, Japan
- Department of Diagnostic Radiology and Neuroradiology, University Medicine Greifswald, Greifswald, Germany
| | - Utaroh Motosugi
- Department of Radiology, University of Yamanashi, 1110 Shimokato, Chuo-shi, 409-3898, Yamanashi, Japan
- Department of Diagnostic Radiology, Kofu Kyoritsu Hospital, Kofu, Yamanashi, Japan
| | - Hiroshi Onishi
- Department of Radiology, University of Yamanashi, 1110 Shimokato, Chuo-shi, 409-3898, Yamanashi, Japan
| |
Collapse
|
10
|
Daimiel Naranjo I, Lo Gullo R, Saccarelli C, Thakur SB, Bitencourt A, Morris EA, Jochelson MS, Sevilimedu V, Martinez DF, Pinker-Domenig K. Diagnostic value of diffusion-weighted imaging with synthetic b-values in breast tumors: comparison with dynamic contrast-enhanced and multiparametric MRI. Eur Radiol 2020; 31:356-367. [PMID: 32780207 PMCID: PMC7755636 DOI: 10.1007/s00330-020-07094-z] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2020] [Revised: 05/22/2020] [Accepted: 07/21/2020] [Indexed: 12/24/2022]
Abstract
Objectives To assess DWI for tumor visibility and breast cancer detection by the addition of different synthetic b-values. Methods Eighty-four consecutive women who underwent a breast-multiparametric-MRI (mpMRI) with enhancing lesions on DCE-MRI (BI-RADS 2–5) were included in this IRB-approved retrospective study from September 2018 to March 2019. Three readers evaluated DW acquired b-800 and synthetic b-1000, b-1200, b-1500, and b-1800 s/mm2 images for lesion visibility and preferred b-value based on lesion conspicuity. Image quality (1–3 scores) and breast composition (BI-RADS) were also recorded. Diagnostic parameters for DWI were determined using a 1–5 malignancy score based on qualitative imaging parameters (acquired + preferred synthetic b-values) and ADC values. BI-RADS classification was used for DCE-MRI and quantitative ADC values + BI-RADS were used for mpMRI. Results Sixty-four malignant (average = 23 mm) and 39 benign (average = 8 mm) lesions were found in 80 women. Although b-800 achieved the best image quality score, synthetic b-values 1200–1500 s/mm2 were preferred for lesion conspicuity, especially in dense breast. b-800 and synthetic b-1000/b-1200 s/mm2 values allowed the visualization of 84–90% of cancers visible with DCE-MRI performing better than b-1500/b-1800 s/mm2. DWI was more specific (86.3% vs 65.7%, p < 0.001) but less sensitive (62.8% vs 90%, p < 0.001) and accurate (71% vs 80.7%, p = 0.003) than DCE-MRI for breast cancer detection, where mpMRI was the most accurate modality accounting for less false positive cases. Conclusion The addition of synthetic b-values enhances tumor conspicuity and could potentially improve tumor visualization particularly in dense breast. However, its supportive role for DWI breast cancer detection is still not definite. Key Points • The addition of synthetic b-values (1200–1500 s/mm2) to acquired DWI afforded a better lesion conspicuity without increasing acquisition time and was particularly useful in dense breasts. • Despite the use of synthetic b-values, DWI was less sensitive and accurate than DCE-MRI for breast cancer detection. • A multiparametric MRI modality still remains the best approach having the highest accuracy for breast cancer detection and thus reducing the number of unnecessary biopsies. Electronic supplementary material The online version of this article (10.1007/s00330-020-07094-z) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Isaac Daimiel Naranjo
- Department of Radiology, Breast Imaging Service, Memorial Sloan Kettering Cancer Center, 300 E 66th Street, New York, NY, 10065, USA
| | - Roberto Lo Gullo
- Department of Radiology, Breast Imaging Service, Memorial Sloan Kettering Cancer Center, 300 E 66th Street, New York, NY, 10065, USA.,Department of Radiology, Breast Imaging Division, Istituto Europeo di Oncologia, Via Giuseppe Ripamonti, 435, 20141, Milano, Italy
| | - Carolina Saccarelli
- Department of Radiology, Breast Imaging Service, Memorial Sloan Kettering Cancer Center, 300 E 66th Street, New York, NY, 10065, USA
| | - Sunitha B Thakur
- Department of Radiology, Breast Imaging Service, Memorial Sloan Kettering Cancer Center, 300 E 66th Street, New York, NY, 10065, USA.,Department of Medical Physics, Memorial Sloan Kettering Cancer Center, 1275 York Ave, New York, NY, 10065, USA
| | - Almir Bitencourt
- Department of Radiology, Breast Imaging Service, Memorial Sloan Kettering Cancer Center, 300 E 66th Street, New York, NY, 10065, USA.,Department of Imaging, A.C.Camargo Cancer Center, SP, São Paulo, Brazil
| | - Elizabeth A Morris
- Department of Radiology, Breast Imaging Service, Memorial Sloan Kettering Cancer Center, 300 E 66th Street, New York, NY, 10065, USA
| | - Maxine S Jochelson
- Department of Radiology, Breast Imaging Service, Memorial Sloan Kettering Cancer Center, 300 E 66th Street, New York, NY, 10065, USA
| | - Varadan Sevilimedu
- Department of Epidemiology and Biostatistics, Memorial Sloan Kettering Cancer Center, 1275 York Ave, New York, NY, 10065, USA
| | - Danny F Martinez
- Department of Radiology, Breast Imaging Service, Memorial Sloan Kettering Cancer Center, 300 E 66th Street, New York, NY, 10065, USA
| | - Katja Pinker-Domenig
- Department of Radiology, Breast Imaging Service, Memorial Sloan Kettering Cancer Center, 300 E 66th Street, New York, NY, 10065, USA. .,Department of Biomedical Imaging and Image-guided Therapy Division of Molecular and Gender Imaging, Medical University of Vienna, Waehringer Guertel 18-20, 1090, Vienna, Austria.
| |
Collapse
|