1
|
Chen TC, Huang YC, Chou TY, Hsu ST, Chen MY, Nosaka K. Effects of far-infrared radiation lamp therapy on recovery from muscle damage induced by eccentric exercise. Eur J Sport Sci 2023; 23:1638-1646. [PMID: 36825876 DOI: 10.1080/17461391.2023.2185163] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/25/2023]
Abstract
The present study investigated the effects of a far-infrared radiation (FIR) lamp therapy on changes in muscle damage and proprioception markers after maximal eccentric exercise of the elbow flexors (EF: Study 1) and the knee flexors (KF: Study 2) in comparison to a sham treatment condition. In each study, 24 healthy sedentary women were assigned to a FIR or a sham treatment group (n = 12/group). They performed 72 maximal EF eccentric contractions (Study 1) or 100 maximal KF eccentric contractions (Study 2) with their non-dominant limbs. They received a 30-min FIR (wavelength: 8-14 µm) or sham treatment at 1, 25, 49, 73 and 97 h post-exercise to the exercised muscles. Maximum voluntary isometric contraction (MVC) torque, muscle soreness, plasma creatine kinase activity, and proprioception assessed by position sense, joint reaction angle, and force match were measured before, and 0.5, 24, 48, 72, 96 and 120 h post-exercise. The outcome measures showed significant changes (P < 0.05) at 0.5-hour post-exercise (before treatment) similarly (P > 0.05) between the conditions in both studies. However, changes in all measures at 24-120 h post-exercise were smaller (P < 0.05) for the FIR than sham condition in both studies. For example, MVC torque returned to the baseline by 72 h post-exercise for the FIR condition in both studies, but was still 19 ± 6% (Study 1) or 17 ± 12% (Study 2) lower than the baseline at 120 h post-exercise for the sham condition. These results suggested that the FIR lamp therapy was effective for accelerating recovery from muscle damage.
Collapse
Affiliation(s)
- Trevor C Chen
- Department of Physical Education and Sport Sciences, National Taiwan Normal University, Taipei City, Taiwan
| | - Yuh-Chuan Huang
- Physical Education Office, Ming Chuan University, Taipei City, Taiwan
| | - Tai-Ying Chou
- Department of Physical Education and Sport Sciences, National Taiwan Normal University, Taipei City, Taiwan
- Department of Athletic Performance, National Taiwan Normal University, Taipei City, Taiwan
| | - Sheng-Tsung Hsu
- Department of Physical Education and Sport Sciences, National Taiwan Normal University, Taipei City, Taiwan
| | - Mei-Yen Chen
- Graduate Institute of Sport, Leisure and Hospitality Management, National Taiwan Normal University, Taipei City, Taiwan
| | - Kazunori Nosaka
- School of Medical and Health Sciences, Centre for Human Performance, Edith Cowan University, Joondalup, Australia
| |
Collapse
|
2
|
Ahokas EK, Ihalainen JK, Hanstock HG, Savolainen E, Kyröläinen H. A post-exercise infrared sauna session improves recovery of neuromuscular performance and muscle soreness after resistance exercise training. Biol Sport 2023; 40:681-689. [PMID: 37398966 PMCID: PMC10286597 DOI: 10.5114/biolsport.2023.119289] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2022] [Revised: 06/19/2022] [Accepted: 08/17/2022] [Indexed: 11/25/2023] Open
Abstract
The aim of this study was to investigate effects of a single infrared sauna (IRS) session on post-exercise recovery of neuromuscular performance, autonomic nervous system function, subjective sleep quality, and muscle soreness. Male basketball players (n = 16) performed two trials consisting of a complex resistance exercise protocol (maximal strength with plyometrics), followed by either 20 min passive recovery (PAS) or IRS (temperature 43 ± 5°C), in a randomized crossover design, with trials separated by one week. Recovery of neuromuscular performance was assessed using 20 m maximal sprint, maximal countermovement-jump (CMJ), and isometric leg press tests, performed 14 hours after exercise. Heart rate (HR), heart rate variability (HRV), sleep diary, muscle soreness, and indirect muscle damage markers were measured pre and post exercise. The decrease in CMJ performance from pre- to post-exercise was attenuated after IRS compared to PAS (p < 0.01). The IRS session resulted in higher HR and lower root mean square of successive differences between normal heartbeats (RMSSD), and high and low frequency power, compared to PAS (p < 0.002). Post-exercise night-time HR and HRV did not differ following IRS vs. PAS. Muscle soreness was less severe, and perceived recovery was higher after IRS compared to PAS (p < 0.01). Post-exercise IRS attenuated the drop in explosive performance and decreased subjective muscle soreness after resistance training, which may enhance mood, readiness, and physical performance of an athlete. A single IRS session had no detrimental effects on recovery of the autonomic nervous system.
Collapse
Affiliation(s)
- Essi K. Ahokas
- Neuromuscular Research Center, Faculty of Sport and Health Sciences, University of Jyväskylä, Finland
| | - Johanna K. Ihalainen
- Neuromuscular Research Center, Faculty of Sport and Health Sciences, University of Jyväskylä, Finland
| | - Helen G. Hanstock
- Swedish Winter Sports Research Centre, Department of Health Sciences, Mid Sweden University, Östersund, Sweden
| | - Eero Savolainen
- Neuromuscular Research Center, Faculty of Sport and Health Sciences, University of Jyväskylä, Finland
| | - Heikki Kyröläinen
- Neuromuscular Research Center, Faculty of Sport and Health Sciences, University of Jyväskylä, Finland
| |
Collapse
|
3
|
Brisola GMP, Dobbs WC, Zagatto AM, Esco MR. Tracking the Fatigue Status after a Resistance Exercise through Different Parameters. Int J Sports Med 2022; 43:941-948. [PMID: 35853461 DOI: 10.1055/a-1766-5945] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
The purpose of the study was to investigate the sensitivity of back squat bar velocity, isometric mid-thigh pull, heart rate variability parameters, perceived recovery scale and step counts for tracking the muscular fatigue time-course (reduction in countermovement jump [CMJ] performance) after strenuous acute lower limb resistance exercise. Sixteen healthy men performed heart rate variability assessment, perceived recovery scale, CMJ, back squat bar velocity, isometric mid-thigh pull, and daily step counts before and 24 h, 48 h and 72 h post a strenuous acute lower limb resistance exercise (8×10 repetitions). The CMJ height decreased at 24 and 48 h after exercise session (p≤0.017), evidencing the muscular fatigue. The perceived recovery scale presented lower values compared to baseline until 72 h after exercise session (p<0.001 for all). The heart rate variability parameters and step counts were not significantly different across time. At 24 h post, only mean force of mid-thigh pull was decreased (p=0.044), while at 48 h post, only peak force of mid-thigh pull was decreased (p=0.020). On the last day (72 h), only bar velocity (mean) presented reduction (p=0.022). Therefore, the perceived recovery scale was the only variable sensible to tracking muscular fatigue, i. e. presenting a similar time-course to CMJ height.
Collapse
Affiliation(s)
- Gabriel Motta Pinheiro Brisola
- Post-Graduate Program in Movement Sciences, São Paulo State University - UNESP, Brazil.,Laboratory of Physiology and Sport Performance (LAFIDE), Department of Physical Education, School of Sciences, São Paulo State University - UNESP, Bauru - SP, Brazil
| | - Ward C Dobbs
- Department of Exercise & Sport Science, University of Wisconsin-La Crosse, La Crosse, WI, United States.,Department of Kinesiology, The University of Alabama, Tuscaloosa, AL, United States
| | - Alessandro Moura Zagatto
- Department of Exercise & Sport Science, University of Wisconsin-La Crosse, La Crosse, WI, United States
| | - Michael R Esco
- Department of Kinesiology, The University of Alabama, Tuscaloosa, AL, United States
| |
Collapse
|
4
|
Ricci M, Mulone A, Elena N, Vecchini E, Valentini R, Gelmini M. Use of a non-medicated plaster in chronic lumbar back pain: a randomized controlled trial. ACTA BIO-MEDICA : ATENEI PARMENSIS 2022; 93:e2022260. [PMID: 36043965 PMCID: PMC9534234 DOI: 10.23750/abm.v93i4.12931] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/19/2022] [Accepted: 07/04/2022] [Indexed: 11/06/2022]
Abstract
BACKGROUND The latest technology on far infrared radiations reflects the radiations emitted by the human body and induces an antalgic and anti-inflammatory effect without active ingredients. Our primary aim was to assess pain level modifications throughout the treatment period with two different types of patches, compared to a placebo. As secondary aims, we focused on addressing patients' quality of life and range of motion changes with each patch. METHODS We assessed 54 patients with chronic lumbar back pain treated with FIT Therapy (far infrared technology) patch. Three different types of FIT Therapy patches (F4, F3, and placebo) were used according to the different power of action and patients allocated in a randomized fashion into the 3 arms of the study. Every single patient was assessed during the study using the VAS pain scale, the Roland Morris Disability Questionnaire for quality of life, and ROM for a total of 14 days. RESULTS Only the F4 patch group significantly reduced pain level at T14 compared to the placebo group (p<0.05). Meanwhile, F3 showed only a non-significant decrease compared to placebo (p=0.254). In terms of lifestyle improvements, both F3 and F4 recorded a decrease on the RMDQ of 4 and 6 points, respectively. CONCLUSIONS Currently, we still need further studies with longer follow-up to consider the FIT Therapy patches F4 a valid alternative as a "non-medicated pain relief", but it proved to have a role in alleviating painful symptoms and improving function in chronic lumbar back pain without adverse events.
Collapse
|
5
|
Coelho TM, Nunes RFH, Nakamura FY, Duffield R, Serpa MC, da Silva JF, Carminatt LJ, Cidral-Filho FJ, Goldim MP, Mathias K, Petronilho F, Martins DF, Guglielmo LGA. Post-Match Recovery in Soccer with Far-Infrared Emitting Ceramic Material or Cold-Water Immersion. J Sports Sci Med 2021; 20:732-742. [PMID: 35321145 DOI: 10.52082/jssm.2021.732] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2020] [Accepted: 09/01/2021] [Indexed: 01/10/2023]
Abstract
We investigated the effects of two common recovery methods; far-infrared emitting ceramic materials (Bioceramic) or cold-water immersion on muscular function and damage after a soccer match. Twenty-five university-level soccer players were randomized into Bioceramic (BIO; n = 8), Cold-water immersion (CWI; n = 9), or Control (CON; n = 8) groups. Heart rate [HR], rating of perceived exertion [RPE], and activity profile through Global Positioning Satellite Systems were measured during the match. Biochemical (thiobarbituric acid reactive species [TBARS], superoxide dismutase [SOD], creatine kinase [CK], lactate dehydrogenase [LDH]), neuromuscular (countermovement [CMJ] and squat jump [SJ], sprints [20-m]), and perceptual markers (delayed-onset muscle soreness [DOMS], and the perceived recovery scale [PRS]) were assessed at pre, post, 24 h, and 48 h post-match. One-way ANOVA was used to compare anthropometric and match performance data. A two-way ANOVA with post-hoc tests compared the timeline of recovery measures. No significant differences existed between groups for anthropometric or match load measures (P > 0.05). Significant post-match increases were observed in SOD, and decreases in TBARS in all groups (p < 0.05), without differences between conditions (p > 0.05). Significant increases in CK, LDH, quadriceps and hamstring DOMS (p < 0.05), as well as decreases in 20-m, SJ, CMJ, and PRS were observed post-match in all groups (p < 0.05), without significant differences between conditions (p > 0.05). Despite the expected post-match muscle damage and impaired performance, neither Bioceramic nor CWI interventions improved post-match recovery.
Collapse
Affiliation(s)
- Tiago M Coelho
- Physical Effort Laboratory, Department of Physical Education, Federal University of Santa Catarina, Florianópolis, SC, Brazil
| | - Renan F H Nunes
- Physical Effort Laboratory, Department of Physical Education, Federal University of Santa Catarina, Florianópolis, SC, Brazil
| | - Fabio Y Nakamura
- Associate Graduate Program in Physical Education UPE/UFPB, João Pessoa, Paraíba, Brazil
| | - Rob Duffield
- Sport & Exercise Discipline Group, University of Technology (UTS), Moore Park, Sydney, Australia
| | - Marília C Serpa
- Physical Effort Laboratory, Department of Physical Education, Federal University of Santa Catarina, Florianópolis, SC, Brazil
| | - Juliano F da Silva
- Physical Effort Laboratory, Department of Physical Education, Federal University of Santa Catarina, Florianópolis, SC, Brazil
| | - Lorival J Carminatt
- Human Performance Research Laboratory, Health Sciences and Sports Center, University of the State of Santa Catarina, Florianópolis, SC, Brazil
| | - Francisco J Cidral-Filho
- Laboratory of Experimental Neurosciences and Graduate Program in Health Sciences, University of Southern Santa Catarina, Palhoça, SC, Brazil
| | - Mariana P Goldim
- Laboratory of Neurobiology of Inflammatory and Metabolic Processes, University of Southern Santa Catarina, Tubarão, SC, Brazil
| | - Khiany Mathias
- Laboratory of Experimental Neurosciences and Graduate Program in Health Sciences, University of Southern Santa Catarina, Palhoça, SC, Brazil
| | - Fabricia Petronilho
- Laboratory of Neurobiology of Inflammatory and Metabolic Processes, University of Southern Santa Catarina, Tubarão, SC, Brazil
| | - Daniel F Martins
- Laboratory of Experimental Neurosciences and Graduate Program in Health Sciences, University of Southern Santa Catarina, Palhoça, SC, Brazil
| | - Luiz G A Guglielmo
- Physical Effort Laboratory, Department of Physical Education, Federal University of Santa Catarina, Florianópolis, SC, Brazil
| |
Collapse
|
6
|
Bontemps B, Gruet M, Vercruyssen F, Louis J. Utilisation of far infrared-emitting garments for optimising performance and recovery in sport: Real potential or new fad? A systematic review. PLoS One 2021; 16:e0251282. [PMID: 33956901 PMCID: PMC8101933 DOI: 10.1371/journal.pone.0251282] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2021] [Accepted: 04/21/2021] [Indexed: 11/26/2022] Open
Abstract
BACKGROUND Thanks to the specific materials they embed, far infrared (FIR)-emitting garments can interact with the body's physiological functions. Such effects have been sought in medicine and physiotherapy for a long time for the treatment/relief of a variety of pathologies and disabling conditions. Recently, FIR-emitting garments have been introduced in the sporting domain under the influence of manufacturers seeing here a new opportunity to support physical performance in athletes, though this is not clearly established. To fill this gap, in this systematic review, we summarize the scientific evidence on the use of FIR-emitting garments in sport and provide directions for future research by shedding light on current scientific limitations. METHOD Five scientific databases (PubMed, Cochrane, ScienceDirect, Scopus and SPORTDiscus) were searched by two independent reviewers. Studies investigating the effects of FIR-emitting garments on at least one physiological outcome related to exercise performance and/or recovery in humans were selected. The methodological quality of retained studies was assessed using the Physiotherapy Evidence Database (PEDro) scale. RESULTS AND DISCUSSION Eleven studies met the inclusion criteria and were included in the systematic review. Studies investigating similar outcomes related to exercise performance or recovery were scarce and results inconclusive, which prevents from drawing firm conclusion about the utilisation of FIR-emitting garments in athletes. However, these early results show that FIR-emitting garments may be of interest for exercise performance and recovery, mainly through their effects on the body's thermoregulation and haemodynamic function. The summary provided in this review can be used to inform the design of future studies. (PROSPERO registration number: CRD42021238029).
Collapse
Affiliation(s)
- Bastien Bontemps
- Université de Toulon, Laboratoire IAPS, Toulon, France
- Research Institute for Sport and Exercise Sciences, Liverpool John Moores University, Liverpool, United Kingdom
| | - Mathieu Gruet
- Université de Toulon, Laboratoire IAPS, Toulon, France
| | | | - Julien Louis
- Research Institute for Sport and Exercise Sciences, Liverpool John Moores University, Liverpool, United Kingdom
| |
Collapse
|