1
|
Hong H, Habib A, Bi L, Wen L. Gas phase ion-molecule reactions of nitroaromatic explosive compounds studied by hollow cathode discharge ionization-mass spectrometry. Talanta 2022; 236:122834. [PMID: 34635224 DOI: 10.1016/j.talanta.2021.122834] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2021] [Revised: 08/26/2021] [Accepted: 08/30/2021] [Indexed: 12/14/2022]
Abstract
In this study, we have developed a variable pressure operating hollow cathode discharge (HCD) ion source to investigate the gas phase ion-molecule reactions of nitroaromatic explosive compounds. The developed HCD ion source coupled MS system has also been validated as an analytical method to analyze explosives at trace levels. The ion source was designed in such a way that the plasma can be generated alternatively at high pressure (~30 Torr), medium pressure (~5 Torr) and low pressure (~1 Torr) regions. The plasma contains a sufficient amount of reactant ions, electrons and excited species, thus the gaseous analyte molecules were efficiently ionized when they passed through the plasma. In the ion-molecule reactions of the nitroaromatic explosives, the discharge products of NOx- (x = 2,3), O3 and HNO3 originating from the plasma-excited air were suggested to contribute to the formation of mostly [M - H]-, [M - NO]-, [M+NO3-HNO2]- and [M-NO+HNO3]- adduct ions at the higher ion source pressures (~5 and 28 Torr) while the electron rich plasma leads to the formation of molecular ion, M-•, at the lower ion source pressure (~1 Torr). Formation of the hydride-adduct ions of the nitroaromatic compounds reveals the surface-assisted Birch type reduction in the HCD plasma. The variety of spectral patterns in the air-assisted glow discharge would be useful for high through-put detection of TNT and TNT-related explosives. An ambient helium dielectric barrier discharge (DBD) ion source was also used and gave identical mass spectra of the nitroaromatic explosive compounds to those observed by the HCD ion source, but did not give any hydride-adduct ions of the explosive compounds. Ion formation mechanism of these ions is also discussed.
Collapse
Affiliation(s)
- Huanhuan Hong
- The Research Institute of Advanced Technologies, Ningbo University, Ningbo, 315211, Zhejiang, China; China Innovation Instrument Co., Ltd, Ningbo, 315000, Zhejiang, China
| | - Ahsan Habib
- The Research Institute of Advanced Technologies, Ningbo University, Ningbo, 315211, Zhejiang, China; Department of Chemistry, University of Dhaka, Dhaka, 1000, Bangladesh.
| | - Lei Bi
- The Research Institute of Advanced Technologies, Ningbo University, Ningbo, 315211, Zhejiang, China; China Innovation Instrument Co., Ltd, Ningbo, 315000, Zhejiang, China
| | - Luhong Wen
- The Research Institute of Advanced Technologies, Ningbo University, Ningbo, 315211, Zhejiang, China; China Innovation Instrument Co., Ltd, Ningbo, 315000, Zhejiang, China.
| |
Collapse
|
2
|
Habib A, Bi L, Wen L. Simultaneous detection and quantification of explosives by a modified hollow cathode discharge ion source. Talanta 2021; 233:122596. [PMID: 34215084 DOI: 10.1016/j.talanta.2021.122596] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2021] [Revised: 06/02/2021] [Accepted: 06/05/2021] [Indexed: 01/13/2023]
Abstract
Detection of explosives at trace levels is crucial for security purposes because of increasing worldwide terrorist threats at public places. Previously, a hollow cathode discharge (HCD) ion source has been fabricated for detection of explosives. Recently, the HCD ion source has been modified for a dual pressures operating system and coupled to a linear ion trap MS to analyze explosives simultaneously. Here, trinitrotoluene (TNT), nitroglycerin (NG), pentaerythritol tetranitrate (PETN) and 1,3,5-trinitroperhydro-1,3,5-triazine (RDX) were taken as model explosive compounds and the mass spectra were recorded in the negative mode ionization. At the higher ion source pressure (~28.0-30.0 Torr), NG, PETN and RDX gave adduct ions with the NO3- ion while TNT showed the [TNT + NO3-HNO2]- (m/z 242) simultaneously. However, NG and PETN did not give any ion signals at the lower ion source pressure (~0.8-1.0 Torr) while TNT exhibited its molecular ion, [TNT]-• (m/z 227), as a major ion through electron attachment and RDX showed fragment ions that followed electron capture dissociation concurrently. The modified HCD ion source exhibited better sensitivity in simultaneous detection and quantification of the explosives. The NO3- and NO2- as reagent ions in the air HCD plasma form stable adduct ions with the NG, PETN and RDX even with TNT at the higher temperature (140-200 °C). The formation of the NO3-, NO2- in the HCD plasma also causes the formation of [TNT-H]- (m/z 226) at the higher ion source pressure. The inner metallic surface of the hollow tube assists the Birch reduction type reaction that results in the formation of hydride ion of the TNT, [TNT + H]- (m/z 228). No significant difference in the spectral pattern for simultaneous and individual measurements for the explosives was observed at the higher ion source pressure. Therefore, it may conclude that the present modified HCD ion source can be used for simultaneous detection and quantification of the explosive compounds at trace and/or ultra-trace levels using air as a carrier gas.
Collapse
Affiliation(s)
- Ahsan Habib
- The Research Institute of Advanced Technologies, Ningbo University, Ningbo, 315211, Zhejiang, China; Department of Chemistry, University of Dhaka, Dhaka, 1000, Bangladesh.
| | - Lei Bi
- The Research Institute of Advanced Technologies, Ningbo University, Ningbo, 315211, Zhejiang, China; China Innovation Instrument Co., Ltd, Ningbo, 315000, Zhejiang, China
| | - Luhong Wen
- The Research Institute of Advanced Technologies, Ningbo University, Ningbo, 315211, Zhejiang, China; China Innovation Instrument Co., Ltd, Ningbo, 315000, Zhejiang, China.
| |
Collapse
|
3
|
Habib A, Bi L, Hong H, Wen L. Challenges and Strategies of Chemical Analysis of Drugs of Abuse and Explosives by Mass Spectrometry. Front Chem 2021; 8:598487. [PMID: 33537286 PMCID: PMC7847941 DOI: 10.3389/fchem.2020.598487] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2020] [Accepted: 12/04/2020] [Indexed: 01/25/2023] Open
Abstract
In analytical science, mass spectrometry (MS) is known as a "gold analytical tool" because of its unique character of providing the direct molecular structural information of the relevant analyte molecules. Therefore, MS technique has widely been used in all branches of chemistry along with in proteomics, metabolomics, genomics, lipidomics, environmental monitoring etc. Mass spectrometry-based methods are very much needed for fast and reliable detection and quantification of drugs of abuse and explosives in order to provide fingerprint information for criminal investigation as well as for public security and safety at public places, respectively. Most of the compounds exist as their neutral form in nature except proteins, peptides, nucleic acids that are in ionic forms intrinsically. In MS, ion source is the heart of the MS that is used for ionizing the electrically neutral molecules. Performance of MS in terms of sensitivity and selectivity depends mainly on the efficiency of the ionization source. Accordingly, much attention has been paid to develop efficient ion sources for a wide range of compounds. Unfortunately, none of the commercial ion sources can be used for ionization of different types of compounds. Moreover, in MS, analyte molecules must be released into the gaseous phase and then ionize by using a suitable ion source for detection/quantification. Under these circumstances, fabrication of new ambient ion source and ultrasonic cutter blade-based non-thermal and thermal desorption methods have been taken into account. In this paper, challenges and strategies of mass spectrometry analysis of the drugs of abuse and explosives through fabrication of ambient ionization sources and new desorption methods for non-volatile compounds have been described. We will focus the literature progress mostly in the last decade and present our views for the future study.
Collapse
Affiliation(s)
- Ahsan Habib
- The Research Institute of Advanced Technologies, Ningbo University, Ningbo, China
- Department of Chemistry, University of Dhaka, Dhaka, Bangladesh
| | - Lei Bi
- The Research Institute of Advanced Technologies, Ningbo University, Ningbo, China
- China Innovation Instrument Co., Ltd., Ningbo, China
| | - Huanhuan Hong
- The Research Institute of Advanced Technologies, Ningbo University, Ningbo, China
- China Innovation Instrument Co., Ltd., Ningbo, China
| | - Luhong Wen
- The Research Institute of Advanced Technologies, Ningbo University, Ningbo, China
- China Innovation Instrument Co., Ltd., Ningbo, China
| |
Collapse
|
4
|
Usmanov DT, Chen LC, Yu Z, Yamabe S, Sakaki S, Hiraoka K. Atmospheric pressure chemical ionization of explosives using alternating current corona discharge ion source. JOURNAL OF MASS SPECTROMETRY : JMS 2015; 50:651-661. [PMID: 26149109 DOI: 10.1002/jms.3552] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/18/2014] [Revised: 10/28/2014] [Accepted: 11/19/2014] [Indexed: 06/04/2023]
Abstract
The high-sensitive detection of explosives is of great importance for social security and safety. In this work, the ion source for atmospheric pressure chemical ionization/mass spectrometry using alternating current corona discharge was newly designed for the analysis of explosives. An electromolded fine capillary with 115 µm inner diameter and 12 mm long was used for the inlet of the mass spectrometer. The flow rate of air through this capillary was 41 ml/min. Stable corona discharge could be maintained with the position of the discharge needle tip as close as 1 mm to the inlet capillary without causing the arc discharge. Explosives dissolved in 0.5 µl methanol were injected to the ion source. The limits of detection for five explosives with 50 pg or lower were achieved. In the ion/molecule reactions of trinitrotoluene (TNT), the discharge products of NOx (-) (x = 2,3), O3 and HNO3 originating from plasma-excited air were suggested to contribute to the formation of [TNT - H](-) (m/z 226), [TNT - NO](-) (m/z 197) and [TNT - NO + HNO3 ](-) (m/z 260), respectively. Formation processes of these ions were traced by density functional theory calculations. Copyright © 2015 John Wiley & Sons, Ltd.
Collapse
Affiliation(s)
- D T Usmanov
- Clean Energy Research Center, University of Yamanashi, 4-3-11 Takeda, Kofu, Yamanashi, 400-8511, Japan
- Institute of Ion-Plasma and Laser Technologies, Dormon Yoli Street 33, Akademgorodok, Tashkent, 100125, Uzbekistan
| | - L C Chen
- Interdisciplinary Graduate School of Medicine and Engineering, University of Yamanashi, 4-3-11 Takeda, Kofu, Yamanashi, 400-8511, Japan
| | - Z Yu
- Clean Energy Research Center, University of Yamanashi, 4-3-11 Takeda, Kofu, Yamanashi, 400-8511, Japan
- School of Chemical and Life Sciences, Shenyang Normal University, Shenyang, 110034, China
| | - S Yamabe
- Fukui Institute of Fundamental Chemistry, Kyoto University, Takano, Sakyoku, Kyoto, 606-8103, Japan
| | - S Sakaki
- Fukui Institute of Fundamental Chemistry, Kyoto University, Takano, Sakyoku, Kyoto, 606-8103, Japan
| | - K Hiraoka
- Clean Energy Research Center, University of Yamanashi, 4-3-11 Takeda, Kofu, Yamanashi, 400-8511, Japan
| |
Collapse
|