Brüggenjürgen B, Braatz F, Greitemann B, Drewitz H, Ruetz A, Schäfer M, Seifert W, Steinfeldt F, Weichold C, Yao D, Stukenborg-Colsman C. Experts' Perceived Patient Burden and Outcomes of Knee-ankle-foot-orthoses (Kafos) Vs. Microprocessor-stance-and-swing-phase-controlled-knee-ankle-foot Orthoses (Mp-sscos).
CANADIAN PROSTHETICS & ORTHOTICS JOURNAL 2022;
5:37795. [PMID:
37614478 PMCID:
PMC10443469 DOI:
10.33137/cpoj.v5i1.37795]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2021] [Accepted: 02/10/2022] [Indexed: 11/23/2022] Open
Abstract
BACKGROUND
Patients with neuromuscular knee-instability assisted with orthotic devices experience problems including pain, falls, mobility issues and limited engagement in daily activities.
OBJECTIVES
The aim of this study was to analyse current real-life burden, needs and orthotic device outcomes in patients in need for advanced orthotic knee-ankle-foot-orthoses (KAFOs).
METHODOLOGY
An observer-based semi-structured telephone interview with orthotic care experts in Germany was applied. Interviews were transcribed and content-analysed. Quantitative questions were analysed descriptively.
FINDINGS
Clinical experts from eight centres which delivered an average of 49.9 KAFOs per year and 13.3 microprocessor-stance-and-swing-phase-controlled-knee-ankle-foot orthoses (MP-SSCOs) since product availability participated. Reported underlying conditions comprised incomplete paraplegia (18%), peripheral nerve lesions (20%), poliomyelitis (41%), post-traumatic lesions (8%) and other disorders (13%). The leading observed patient burdens were "restriction of mobility" (n=6), followed by "emotional strain" (n=5) and "impaired gait pattern" (n=4). Corresponding results for potential patient benefits were seen in "improved quality-of-life" (n=8) as well as "improved gait pattern" (n=8) followed by "high reliability of the orthosis" (n=7). In total, experts reported falls occurring in 71.5% of patients at a combined annual frequency of 7.0 fall events per year when using KAFOs or stance control orthoses (SCOs). In contrast, falls were observed in only 7.2 % of MPSSCO users.
CONCLUSION
Advanced orthotic technology might contribute to better quality of life of patients, improved gait pattern and perceived reliability of orthosis. In terms of safety a substantial decrease in frequency of falls was observed when comparing KAFO and MP-SSCO users.