1
|
Wang J, Bermudez D, Chen W, Durgavarjhula D, Randell C, Uyanik M, McMillan A. Motion-correction strategies for enhancing whole-body PET imaging. FRONTIERS IN NUCLEAR MEDICINE (LAUSANNE, SWITZERLAND) 2024; 4:1257880. [PMID: 39118964 PMCID: PMC11308502 DOI: 10.3389/fnume.2024.1257880] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Indexed: 08/10/2024]
Abstract
Positron Emission Tomography (PET) is a powerful medical imaging technique widely used for detection and monitoring of disease. However, PET imaging can be adversely affected by patient motion, leading to degraded image quality and diagnostic capability. Hence, motion gating schemes have been developed to monitor various motion sources including head motion, respiratory motion, and cardiac motion. The approaches for these techniques have commonly come in the form of hardware-driven gating and data-driven gating, where the distinguishing aspect is the use of external hardware to make motion measurements vs. deriving these measures from the data itself. The implementation of these techniques helps correct for motion artifacts and improves tracer uptake measurements. With the great impact that these methods have on the diagnostic and quantitative quality of PET images, much research has been performed in this area, and this paper outlines the various approaches that have been developed as applied to whole-body PET imaging.
Collapse
Affiliation(s)
- James Wang
- Department of Radiology, University of Wisconsin Madison, Madison, WI, United States
- Department of Medical Physics, University of Wisconsin Madison, Madison, WI, United States
| | - Dalton Bermudez
- Department of Medical Physics, University of Wisconsin Madison, Madison, WI, United States
| | - Weijie Chen
- Department of Radiology, University of Wisconsin Madison, Madison, WI, United States
- Department of Electrical and Computer Engineering, University of Wisconsin Madison, Madison, WI, United States
| | - Divya Durgavarjhula
- Department of Radiology, University of Wisconsin Madison, Madison, WI, United States
- Department of Computer Science, University of Wisconsin Madison, Madison, WI, United States
| | - Caitlin Randell
- Department of Radiology, University of Wisconsin Madison, Madison, WI, United States
- Department of Biomedical Engineering, University of Wisconsin Madison, Madison, WI, United States
| | - Meltem Uyanik
- Department of Radiology, University of Wisconsin Madison, Madison, WI, United States
- Department of Medical Physics, University of Wisconsin Madison, Madison, WI, United States
| | - Alan McMillan
- Department of Radiology, University of Wisconsin Madison, Madison, WI, United States
- Department of Medical Physics, University of Wisconsin Madison, Madison, WI, United States
- Department of Electrical and Computer Engineering, University of Wisconsin Madison, Madison, WI, United States
- Department of Biomedical Engineering, University of Wisconsin Madison, Madison, WI, United States
- Data Science Institute, University of Wisconsin Madison, Madison, WI, United States
| |
Collapse
|
2
|
Grootjans W, Rietbergen DDD, van Velden FHP. Added Value of Respiratory Gating in Positron Emission Tomography for the Clinical Management of Lung Cancer Patients. Semin Nucl Med 2022; 52:745-758. [DOI: 10.1053/j.semnuclmed.2022.04.006] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2022] [Accepted: 04/21/2022] [Indexed: 12/24/2022]
|
3
|
Low-Dose PET Imaging of Tumors in Lung and Liver Regions Using Internal Motion Estimation. Diagnostics (Basel) 2021; 11:diagnostics11112138. [PMID: 34829485 PMCID: PMC8625002 DOI: 10.3390/diagnostics11112138] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2021] [Revised: 11/12/2021] [Accepted: 11/15/2021] [Indexed: 11/23/2022] Open
Abstract
Motion estimation and compensation are necessary for improvement of tumor quantification analysis in positron emission tomography (PET) images. The aim of this study was to propose adaptive PET imaging with internal motion estimation and correction using regional artificial evaluation of tumors injected with low-dose and high-dose radiopharmaceuticals. In order to assess internal motion, molecular sieves imitating tumors were loaded with 18F and inserted into the lung and liver regions in rats. All models were classified into two groups, based on the injected radiopharmaceutical activity, to compare the effect of tumor intensity. The PET study was performed with injection of F-18 fluorodeoxyglucose (18F-FDG). Respiratory gating was carried out by external trigger device. Count, signal to noise ratio (SNR), contrast and full width at half maximum (FWHM) were measured in artificial tumors in gated images. Motion correction was executed by affine transformation with estimated internal motion data. Monitoring data were different from estimated motion. Contrast in the low-activity group was 3.57, 4.08 and 6.19, while in the high-activity group it was 10.01, 8.36 and 6.97 for static, 4 bin and 8 bin images, respectively. The results of the lung target in 4 bin and the liver target in 8 bin showed improvement in FWHM and contrast with sufficient SNR. After motion correction, FWHM was improved in both regions (lung: 24.56%, liver: 10.77%). Moreover, with the low dose of radiopharmaceuticals the PET image visualized specific accumulated radiopharmaceutical areas in the liver. Therefore, low activity in PET images should undergo motion correction before quantification analysis using PET data. We could improve quantitative tumor evaluation by considering organ region and tumor intensity.
Collapse
|
4
|
Kim DH, Yoo EH, Hong US, Kim JH, Ko YH, Moon SC, Cheon M, Yoo J. Image Registration of 18F-FDG PET/CT Using the MotionFree Algorithm and CT Protocols through Phantom Study and Clinical Evaluation. Healthcare (Basel) 2021; 9:669. [PMID: 34199705 PMCID: PMC8229608 DOI: 10.3390/healthcare9060669] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2021] [Revised: 05/25/2021] [Accepted: 06/03/2021] [Indexed: 12/25/2022] Open
Abstract
We evaluated the benefits of the MotionFree algorithm through phantom and patient studies. The various sizes of phantom and vacuum vials were linked to RPM moving with or without MotionFree application. A total of 600 patients were divided into six groups by breathing protocols and CT scanning time. Breathing protocols were applied as follows: (a) patients who underwent scanning without any breathing instructions; (b) patients who were instructed to hold their breath after expiration during CT scan; and (c) patients who were instructed to breathe naturally. The length of PET/CT misregistration was measured and we defined the misregistration when it exceeded 10 mm. In the phantom tests, the images produced by the MotionFree algorithm were observed to have excellent agreement with static images. There were significant differences in PET/CT misregistration according to CT scanning time and each breathing protocol. When applying the type (c) protocol, decreasing the CT scanning time significantly reduced the frequency and length of misregistrations (p < 0.05). The MotionFree application is able to correct respiratory motion artifacts and to accurately quantify lesions. The shorter time of CT scan can reduce the frequency, and the natural breathing protocol also decreases the lengths of misregistrations.
Collapse
Affiliation(s)
- Deok-Hwan Kim
- Department of Nuclear Medicine, Veterans Health Service Medical Center, Seoul 05368, Korea; (D.-H.K.); (E.-H.Y.); (U.-S.H.); (J.-H.K.); (Y.-H.K.); (M.C.)
| | - Eun-Hye Yoo
- Department of Nuclear Medicine, Veterans Health Service Medical Center, Seoul 05368, Korea; (D.-H.K.); (E.-H.Y.); (U.-S.H.); (J.-H.K.); (Y.-H.K.); (M.C.)
| | - Ui-Seong Hong
- Department of Nuclear Medicine, Veterans Health Service Medical Center, Seoul 05368, Korea; (D.-H.K.); (E.-H.Y.); (U.-S.H.); (J.-H.K.); (Y.-H.K.); (M.C.)
| | - Jun-Hyeok Kim
- Department of Nuclear Medicine, Veterans Health Service Medical Center, Seoul 05368, Korea; (D.-H.K.); (E.-H.Y.); (U.-S.H.); (J.-H.K.); (Y.-H.K.); (M.C.)
| | - Young-Heon Ko
- Department of Nuclear Medicine, Veterans Health Service Medical Center, Seoul 05368, Korea; (D.-H.K.); (E.-H.Y.); (U.-S.H.); (J.-H.K.); (Y.-H.K.); (M.C.)
| | | | - Miju Cheon
- Department of Nuclear Medicine, Veterans Health Service Medical Center, Seoul 05368, Korea; (D.-H.K.); (E.-H.Y.); (U.-S.H.); (J.-H.K.); (Y.-H.K.); (M.C.)
| | - Jang Yoo
- Department of Nuclear Medicine, Veterans Health Service Medical Center, Seoul 05368, Korea; (D.-H.K.); (E.-H.Y.); (U.-S.H.); (J.-H.K.); (Y.-H.K.); (M.C.)
| |
Collapse
|