1
|
Liu G, Gu T, Chen S, Gu Y, Yu H, Shi H. Total-body dynamic PET/CT imaging reveals kinetic distribution of [ 13N]NH 3 in normal organs. Eur J Nucl Med Mol Imaging 2024:10.1007/s00259-024-06826-3. [PMID: 38976037 DOI: 10.1007/s00259-024-06826-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2024] [Accepted: 06/30/2024] [Indexed: 07/09/2024]
Abstract
PURPOSE To systematically investigate kinetic metrics and metabolic trapping of [13N]NH3 in organs. METHODS Eleven participants performed total-body [13N]NH3 dynamic positron emission tomography (PET). Regions of interest were drawn in organs to obtain time-to-activity curves (TACs), which were fitted with an irreversible two-tissue compartment model (2TC) to investigate constant rates K1, k2 and k3, and to calculate Ki. Additionally, one-tissue compartment model using full data (1TCfull) and the first four minutes of data (1TC4min) were fitted to TAC data. K1 and k2 were compared among different models to assess [13N]NH3 trapping in organs. RESULTS Kinetic rates of [13N]NH3 varied significantly among organs. The mean K1 ranged from 0.049 mL/cm3/min in the muscle to 2.936 mL/cm3/min in the kidney. The k2 and k3 were lowest in the liver (0.001 min- 1) and in the pituitary (0.009 min- 1), while highest in the kidney (0.587 min- 1) and in the liver (0.800 min- 1), respectively. The Ki was largest in the myocardium (0.601 ± 0.259 mL/cm3/min) while smallest in the bone marrow (0.028 ± 0.022 mL/cm3/min). Three groups of organs with similar kinetic characteristics were revealed: (1) the thyroid, the lung, the spleen, the pancreas, and the kidney; (2) the liver and the muscle; and (3) the cortex, the white matter, the cerebellum, the pituitary, the parotid, the submandibular gland, the myocardium, the bone, and the bone marrow. Obvious k3 was identified in multiple organs, and significant changes of K1 in multiple organs and k2 in most organs were found between 2TC and 1TCfull, but both K1 and k2 were comparable between 2TC and 1TC4min. CONCLUSION The kinetic rates of [13N]NH3 differed among organs with some have obvious 13N-anmmonia trapping. The normal distribution of kinetic metrics of 13N-anmmonia in organs can serve as a reference for its potential use in tumor imaging.
Collapse
Affiliation(s)
- Guobing Liu
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, No. 180 in Fenglin Road, Shanghai, 200032, P.R. China
- Institute of Nuclear Medicine, Fudan University, Shanghai, China
- Shanghai Institute of Medical Imaging, Shanghai, China
- Cancer Prevention and Treatment Center, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Taoying Gu
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, No. 180 in Fenglin Road, Shanghai, 200032, P.R. China
- Institute of Nuclear Medicine, Fudan University, Shanghai, China
- Shanghai Institute of Medical Imaging, Shanghai, China
- Cancer Prevention and Treatment Center, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Shuguang Chen
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, No. 180 in Fenglin Road, Shanghai, 200032, P.R. China
- Institute of Nuclear Medicine, Fudan University, Shanghai, China
- Shanghai Institute of Medical Imaging, Shanghai, China
- Cancer Prevention and Treatment Center, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Yushen Gu
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, No. 180 in Fenglin Road, Shanghai, 200032, P.R. China
- Institute of Nuclear Medicine, Fudan University, Shanghai, China
- Shanghai Institute of Medical Imaging, Shanghai, China
- Cancer Prevention and Treatment Center, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Haojun Yu
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, No. 180 in Fenglin Road, Shanghai, 200032, P.R. China
- Institute of Nuclear Medicine, Fudan University, Shanghai, China
- Shanghai Institute of Medical Imaging, Shanghai, China
- Cancer Prevention and Treatment Center, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Hongcheng Shi
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, No. 180 in Fenglin Road, Shanghai, 200032, P.R. China.
- Institute of Nuclear Medicine, Fudan University, Shanghai, China.
- Shanghai Institute of Medical Imaging, Shanghai, China.
- Cancer Prevention and Treatment Center, Zhongshan Hospital, Fudan University, Shanghai, China.
| |
Collapse
|
2
|
Yin H, Liu G, Mao W, Lv J, Yu H, Cheng D, Cai L, Shi H. Parametric net influx rate imaging of 68Ga-DOTATATE in patients with neuroendocrine tumors: assessment of lesion detectability. Ann Nucl Med 2024; 38:483-492. [PMID: 38573411 DOI: 10.1007/s12149-024-01922-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2023] [Accepted: 03/07/2024] [Indexed: 04/05/2024]
Abstract
OBJECTIVES There has been developed a clinical dynamic total-body 68Ga-DOTATATE PET/CT imaging protocol that allows quantitative imaging of net influx rate (Ki). Using qualitative and quantitative analyses of clinical studies, this retrospective study aims to assess whether parametric Ki images improve lesion detectability. METHODS Using a 194-cm axial field-of-view PET/CT scanner, 52 patients with neuroendocrine tumors underwent a 60-min dynamic total-body 68Ga-DOTATATE scan. Parametric Ki images and static standardized uptake value (SUV) images were generated. In addition to visual inspection of both sets of images, a quantitative analysis of 249 individual lesions was conducted using the target-to-background (TBR) metric. RESULTS There were 52 patients who underwent dynamic total-body 68Ga-DOTATATE PET/CT scans. A total of 249 lesions were evaluated, of which 66 lesions were biopsy-proven and 183 lesions were unproven. Ki images produced two fewer false positives than the SUV images. Overall, our results from 66 proven NET lesions suggested similar sensitivity (98.5%) but improved accuracy (from 95.6 to 97.1%) and potentially enhanced specificity with Ki over SUV imaging. Besides, there was no difference in the number of pathological lesions identified visually in both images. However, Ki TBR was significantly higher than SUV TBR quantitatively (P < 0.001). CONCLUSIONS Patlak Ki imaging provides nuclear physicians with a PET image with higher tumor contrast which may enhance confidence in diagnosis with possibly reduced false positive results, albeit an equivalent detectability, compared to static SUV image.
Collapse
Affiliation(s)
- Hongyan Yin
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, No. 180 in Fenglin Road, Shanghai, 200032, People's Republic of China
| | - Guobing Liu
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, No. 180 in Fenglin Road, Shanghai, 200032, People's Republic of China
| | - Wujian Mao
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, No. 180 in Fenglin Road, Shanghai, 200032, People's Republic of China
| | - Jing Lv
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, No. 180 in Fenglin Road, Shanghai, 200032, People's Republic of China
| | - Haojun Yu
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, No. 180 in Fenglin Road, Shanghai, 200032, People's Republic of China
| | - Dengfeng Cheng
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, No. 180 in Fenglin Road, Shanghai, 200032, People's Republic of China
| | - Liang Cai
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, No. 180 in Fenglin Road, Shanghai, 200032, People's Republic of China
| | - Hongcheng Shi
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, No. 180 in Fenglin Road, Shanghai, 200032, People's Republic of China.
| |
Collapse
|
3
|
Burasothikul P, Navikhacheevin C, Pasawang P, Sontrapornpol T, Sukprakun C, Khamwan K. Dual-time-point dynamic 68Ga-PSMA-11 PET/CT for parametric imaging generation in prostate cancer. Ann Nucl Med 2024:10.1007/s12149-024-01939-z. [PMID: 38761312 DOI: 10.1007/s12149-024-01939-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2024] [Accepted: 05/07/2024] [Indexed: 05/20/2024]
Abstract
PURPOSE To investigate the optimal dual-time-point (DTP) approaches using dynamic 68Ga-PSMA-11 PET/CT imaging to generate parametric images for prostate cancer patients. METHODS Fifteen patients with prostate cancer were intravenously administered 68Ga-PSMA-11 of 181.9 ± 47.2 MBq, followed by an immediate 60 min dynamic PET/CT scan. List-mode data were reconstructed into 25 timeframes (6 × 10 s, 8 × 30 s, and 11 × 300 s) and corrected for motion and partial volume effect. DTP parametric images were generated using different interval time points of 5 min and 10 min, with a minimum of 30 min time interval. Net influx rates (Ki) were calculated through the fitting of a single irreversible two-tissue compartmental model. Intraclass correlation coefficient (ICC) values between DTP protocols and 60 min Ki were obtained. Lesion-to-background ratios (LBRs) of Ki and standardized uptake value (SUV) images in each DTP protocol were determined. RESULTS The DTP protocol of 5-10 min with a 40-45 min interval showed the highest ICC of 0.988 compared with the 60 min Ki, whereas the ICC values for the intervals of 0-5 min with 55-60 min and 0-10 min with 50-60 min were 0.941. The LBRs of the 60 min Ki, 5-10 min with 40-45 min Ki, 0-5 min with 55-60 min Ki, 0-10 min with 50-60 min Ki, SUVmean, and SUVmax images were 29.53 ± 27.33, 13.05 ± 15.28, 45.15 ± 53.11, 45.52 ± 70.31, 19.77 ± 23.43, and 25.06 ± 30.07, respectively. CONCLUSION The 0-5 min with 55-60 min DTP parametric imaging exhibits a comparable Ki to 60 min parametric imaging and remarkable image quality and contrast than SUV imaging, enhancing prostate cancer diagnosis while maintaining time efficiency.
Collapse
Affiliation(s)
- Paphawarin Burasothikul
- Medical Physics Program, Department of Radiology, Faculty of Medicine, Chulalongkorn University, Bangkok, 10330, Thailand
- School of Radiological Technology, Faculty of Health Science Technology, HRH Princess Chulabhorn College of Medical Science, Bangkok, 10210, Thailand
- Chulalongkorn University Biomedical Imaging Group, Department of Radiology, Faculty of Medicine, Chulalongkorn University, Bangkok, 10330, Thailand
| | - Chatchai Navikhacheevin
- Division of Nuclear Medicine, King Chulalongkorn Memorial Hospital, Thai Red Cross Society, Bangkok, 10330, Thailand
| | - Panya Pasawang
- Division of Nuclear Medicine, King Chulalongkorn Memorial Hospital, Thai Red Cross Society, Bangkok, 10330, Thailand
| | - Tanawat Sontrapornpol
- Division of Nuclear Medicine, King Chulalongkorn Memorial Hospital, Thai Red Cross Society, Bangkok, 10330, Thailand
| | - Chanan Sukprakun
- Division of Nuclear Medicine, Department of Radiology, Faculty of Medicine, Chulalongkorn University, Bangkok, 10330, Thailand
| | - Kitiwat Khamwan
- Medical Physics Program, Department of Radiology, Faculty of Medicine, Chulalongkorn University, Bangkok, 10330, Thailand.
- Chulalongkorn University Biomedical Imaging Group, Department of Radiology, Faculty of Medicine, Chulalongkorn University, Bangkok, 10330, Thailand.
- Division of Nuclear Medicine, Department of Radiology, Faculty of Medicine, Chulalongkorn University, Bangkok, 10330, Thailand.
| |
Collapse
|
4
|
Ince S, Laforest R, Itani M, Prasad V, Ashrafinia S, Smith AM, Wahl RL, Fraum TJ. Patlak Slope versus Standardized Uptake Value Image Quality in an Oncologic PET/CT Population: A Prospective Cross-Sectional Study. Diagnostics (Basel) 2024; 14:883. [PMID: 38732298 PMCID: PMC11083784 DOI: 10.3390/diagnostics14090883] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2024] [Revised: 04/12/2024] [Accepted: 04/22/2024] [Indexed: 05/13/2024] Open
Abstract
Patlak slope (PS) images have the potential to improve lesion conspicuity compared with standardized uptake value (SUV) images but may be more artifact-prone. This study compared PS versus SUV image quality and hepatic tumor-to-background ratios (TBRs) at matched time points. Early and late SUV and PS images were reconstructed from dynamic positron emission tomography (PET) data. Two independent, blinded readers scored image quality metrics (a four-point Likert scale) and counted tracer-avid lesions. Hepatic lesions and parenchyma were segmented and quantitatively analyzed. Differences were assessed via the Wilcoxon signed-rank test (alpha, 0.05). Forty-three subjects were included. For overall quality and lesion detection, early PS images were significantly inferior to other reconstructions. For overall quality, late PS images (reader 1 [R1]: 3.95, reader 2 [R2]: 3.95) were similar (p > 0.05) to early SUV images (R1: 3.88, R2: 3.84) but slightly superior (p ≤ 0.002) to late SUV images (R1: 2.97, R2: 3.44). For lesion detection, late PS images were slightly inferior to late SUV images (R1 only) but slightly superior to early SUV images (both readers). PS-based TBRs were significantly higher than SUV-based TBRs at the early time point, with opposite findings at the late time point. In conclusion, late PS images are similar to early/late SUV images in image quality and lesion detection; the superiority of SUV versus PS hepatic TBRs is time-dependent.
Collapse
Affiliation(s)
- Semra Ince
- Department of Radiology, Washington University School of Medicine, 510 S. Kingshighway Blvd, Campus Box 8131, St. Louis, MO 63110, USA; (S.I.); (R.L.); (M.I.); (V.P.); (R.L.W.)
| | - Richard Laforest
- Department of Radiology, Washington University School of Medicine, 510 S. Kingshighway Blvd, Campus Box 8131, St. Louis, MO 63110, USA; (S.I.); (R.L.); (M.I.); (V.P.); (R.L.W.)
| | - Malak Itani
- Department of Radiology, Washington University School of Medicine, 510 S. Kingshighway Blvd, Campus Box 8131, St. Louis, MO 63110, USA; (S.I.); (R.L.); (M.I.); (V.P.); (R.L.W.)
| | - Vikas Prasad
- Department of Radiology, Washington University School of Medicine, 510 S. Kingshighway Blvd, Campus Box 8131, St. Louis, MO 63110, USA; (S.I.); (R.L.); (M.I.); (V.P.); (R.L.W.)
| | - Saeed Ashrafinia
- Siemens Medical Solutions USA, Inc., 810 Innovation Drive, Knoxville, TN 37932, USA; (S.A.); (A.M.S.)
| | - Anne M. Smith
- Siemens Medical Solutions USA, Inc., 810 Innovation Drive, Knoxville, TN 37932, USA; (S.A.); (A.M.S.)
| | - Richard L. Wahl
- Department of Radiology, Washington University School of Medicine, 510 S. Kingshighway Blvd, Campus Box 8131, St. Louis, MO 63110, USA; (S.I.); (R.L.); (M.I.); (V.P.); (R.L.W.)
- Department of Radiation Oncology, Washington University School of Medicine, 660 S. Euclid Ave, MSC 8224-35-LL, St. Louis, MO 63110, USA
| | - Tyler J. Fraum
- Department of Radiology, Washington University School of Medicine, 510 S. Kingshighway Blvd, Campus Box 8131, St. Louis, MO 63110, USA; (S.I.); (R.L.); (M.I.); (V.P.); (R.L.W.)
| |
Collapse
|
5
|
Liu G, Shi Y, Hou X, Yu H, Hu Y, Zhang Y, Shi H. Dynamic total-body PET/CT imaging with reduced acquisition time shows acceptable performance in quantification of [ 18F]FDG tumor kinetic metrics. Eur J Nucl Med Mol Imaging 2024; 51:1371-1382. [PMID: 38078950 DOI: 10.1007/s00259-023-06526-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2023] [Accepted: 11/14/2023] [Indexed: 03/22/2024]
Abstract
PURPOSE To investigate the feasibility of reducing the acquisition time for continuous dynamic positron emission tomography (PET) while retaining acceptable performance in quantifying kinetic metrics of 2-[18F]-fluoro-2-deoxy-D-glucose ([18F]FDG) in tumors. METHODS In total, 78 oncological patients underwent total-body dynamic PET imaging for ≥ 60 min, with 8, 20, and 50 patients receiving full activity (3.7 MBq/kg), half activity (1.85 MBq/kg), and ultra-low activity (0.37 MBq/kg) of [18F]FDG, respectively. The dynamic data were divided into 21-, 30-, 45- and ≥ 60-min groups. The kinetic analysis involved model fitting to derive constant rates (VB, K1 to k3, and Ki) for both tumors and normal tissues, using both reversible and irreversible two-tissue-compartment models. One-way ANOVA with repeated measures or the Freidman test compared the kinetic metrics among groups, while the Deming regression assessed the correlation of kinetic metrics among groups. RESULTS All kinetic metrics in the 30-min and 45-min groups were statistically comparable to those in the ≥ 60-min group. The relative differences between the 30-min and ≥ 60-min groups ranged from 12.3% ± 15.1% for K1 to 29.8% ± 30.0% for VB, and those between the 45-min and ≥ 60-min groups ranged from 7.5% ± 8.7% for Ki to 24.0% ± 24.3% for VB. However, this comparability was not observed between the 21-min and ≥ 60-min groups. The significance trend of these comparisons remained consistent across different models (reversible or irreversible), administrated activity levels, and partial volume corrections for lesions. Significant correlations in tumor kinetic metrics were identified between the 30-/45-min and ≥ 60-min groups, with Deming regression slopes > 0.813. In addition, the comparability of kinetic metrics between the 30-min and ≥ 60-min groups were established for normal tissues. CONCLUSION The acquisition time for dynamic PET imaging can be reduced to 30 min without compromising the ability to reveal tumor kinetic metrics of [18F]FDG, using the total-body PET/CT system.
Collapse
Affiliation(s)
- Guobing Liu
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, 180 Fenglin Road, Shanghai, 200032, P.R. China
- Department of Nuclear Medicine, Zhongshan Hospital (Xiamen), Fudan University, Xiamen, 361015, China
- Institute of Nuclear Medicine, Fudan University, Shanghai, 200032, China
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China
- Cancer Prevention and Treatment Center, Zhongshan Hospital, Fudan University, Shanghai, 200032, China
- Xiamen Municipal Clinical Research Center for Medical Imaging, Xiamen, 361015, China
| | - Yimeng Shi
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, 180 Fenglin Road, Shanghai, 200032, P.R. China
- Institute of Nuclear Medicine, Fudan University, Shanghai, 200032, China
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China
- Cancer Prevention and Treatment Center, Zhongshan Hospital, Fudan University, Shanghai, 200032, China
| | - Xiaoguang Hou
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, 180 Fenglin Road, Shanghai, 200032, P.R. China
- Institute of Nuclear Medicine, Fudan University, Shanghai, 200032, China
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China
- Cancer Prevention and Treatment Center, Zhongshan Hospital, Fudan University, Shanghai, 200032, China
| | - Haojun Yu
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, 180 Fenglin Road, Shanghai, 200032, P.R. China
- Institute of Nuclear Medicine, Fudan University, Shanghai, 200032, China
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China
- Cancer Prevention and Treatment Center, Zhongshan Hospital, Fudan University, Shanghai, 200032, China
| | - Yan Hu
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, 180 Fenglin Road, Shanghai, 200032, P.R. China
- Institute of Nuclear Medicine, Fudan University, Shanghai, 200032, China
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China
- Cancer Prevention and Treatment Center, Zhongshan Hospital, Fudan University, Shanghai, 200032, China
| | - Yiqiu Zhang
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, 180 Fenglin Road, Shanghai, 200032, P.R. China
- Institute of Nuclear Medicine, Fudan University, Shanghai, 200032, China
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China
- Cancer Prevention and Treatment Center, Zhongshan Hospital, Fudan University, Shanghai, 200032, China
| | - Hongcheng Shi
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, 180 Fenglin Road, Shanghai, 200032, P.R. China.
- Department of Nuclear Medicine, Zhongshan Hospital (Xiamen), Fudan University, Xiamen, 361015, China.
- Institute of Nuclear Medicine, Fudan University, Shanghai, 200032, China.
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China.
- Cancer Prevention and Treatment Center, Zhongshan Hospital, Fudan University, Shanghai, 200032, China.
- Xiamen Municipal Clinical Research Center for Medical Imaging, Xiamen, 361015, China.
| |
Collapse
|
6
|
Reshtebar N, Hosseini SA, Zhuang M, Sheikhzadeh P. Estimation of kinetic parameters in dynamic FDG PET imaging based on shortened protocols: a virtual clinical study. Phys Eng Sci Med 2024; 47:199-213. [PMID: 38078995 DOI: 10.1007/s13246-023-01356-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2023] [Accepted: 11/12/2023] [Indexed: 03/26/2024]
Abstract
This study investigated the estimation of kinetic parameters and production of related parametric Ki images in FDG PET imaging using the proposed shortened protocol (three 3-min/bed routine static images) by means of the simulated annealing (SA) algorithm. Six realistic heterogeneous tumors and various levels of [18F] FDG uptake were simulated by the XCAT phantom. An irreversible two-tissue compartment model (2TCM) using population-based input function was employed. By keeping two routine clinical scans fixed (60-min and 90-min post injection), the effect of the early scan time on optimizing the estimation of the pharmacokinetic parameters was investigated. The SA optimization algorithm was applied to estimate micro- and macro-parameters (K1, k2, k3, Ki). The minimum bias for most parameters was observed at a scan time of 20-min, which was < 10%. A highly significant correlation (> 0.9) as well as limited bias (< 10%) were observed between kinetic parameters generated from two methods [two-tissue compartment full dynamic scan (2TCM-full) and two-tissue compartment by SA algorithm (2TCM-SA)]. The analysis showed a strong correlation (> 0.8) between (2TCM-SA) Ki and SUV images. In addition, the tumor-to-background ratio (TBR) metric in the parametric (2TCM-SA) Ki images was significantly higher than SUV, although the SUV images provide better Contrast-to-noise ratio relative to parametric (2TCM-SA) Ki images. The proposed shortened protocol by the SA algorithm can estimate the kinetic parameters in FDG PET scan with high accuracy and robustness. It was also concluded that the parametric Ki images obtained from the 2TCM-SA as a complementary image of the SUV possess more quantification information than SUV images and can be used by the nuclear medicine specialist. This method has the potential to be an alternative to a full dynamic PET scan.
Collapse
Affiliation(s)
- Niloufar Reshtebar
- Department of Energy Engineering, Sharif University of Technology, Tehran, 8639-11365, Iran
| | - Seyed Abolfazl Hosseini
- Department of Energy Engineering, Sharif University of Technology, Tehran, 8639-11365, Iran.
| | - Mingzan Zhuang
- Department of Nuclear Medicine, Meizhou People's Hospital, Meizhou, 514011, China
| | - Peyman Sheikhzadeh
- Department of Medical Physics and Biomedical Engineering, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran
- Nuclear Medicine Department, Imam Khomeini Hospital Complex, Tehran University of Medical Sciences, Tehran, Iran
| |
Collapse
|
7
|
Dynamic Total-Body PET/CT Imaging Reveals Kinetic Distribution of 68Ga-DOTATATE in Normal Organs. CONTRAST MEDIA & MOLECULAR IMAGING 2023; 2023:4722499. [PMID: 36713636 PMCID: PMC9876673 DOI: 10.1155/2023/4722499] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/13/2022] [Revised: 12/29/2022] [Accepted: 12/30/2022] [Indexed: 01/20/2023]
Abstract
Objective To investigate the biodistribution and kinetic constants of 68Ga-DOTATATE in normal organs through dynamic total-body positron emission tomography/computed tomography (PET/CT). Methods Seven patients who experienced endoscopic resection of gastric neuroendocrine tumor were enrolled. Dynamic total-body PET/CT scans over 60 min were performed. Time-activity curves were obtained by drawing regions of interest in normal organs. Rate constants, including K 1, k 2, k 3, and vB, were computed using a two-tissue compartment model. Factor analysis was used to compare the rate constants among subjects and regions. Hierarchical cluster analysis was performed to identify organs with similar kinetic characteristics. Results The highest uptake of 68Ga-DOTATATE was observed in the spleen followed by kidneys, adrenals, liver, pituitary gland, pancreas head, prostate, pancreas body, and thyroid, parotid, and submandibular glands. Low background level of 68Ga-DOTATATE uptake was observed in the nasal mucosa, bone, blood pool, and cerebrum. In addition, the uptake in the pancreas head was noted to be higher than the pancreas body (P < 0.001) on the basis of each time point of dynamic PET. There were differences of rate constants among different organs. The mean K 1 ranged from 0.0507 min-1 in the left nasal mucosa to 1.21 min-1 in the left kidney, and mean k 2 ranged from 0.0174 min-1 in the spleen to 4.4487 min-1 in the left cerebrum. The mean k 3 ranged from 0.0563 min-1 in the right cerebrum to 4.6309 min-1 in the left adrenal, and mean vB ranged from 0.0001 in the left cerebrum to 0.2489 in the right adrenal. However, none of the rate constants was significantly different among subjects or among different sites within a single organ. Three groups of organs with similar kinetic characteristics were identified: (1) cerebrum; (2) pituitary gland, liver, adrenal, and prostate; and (3) nasal mucosa, parotid and submandibular glands, thyroid, spleen, pancreas, kidney, and bone. Conclusion Uptake and clearance of 68Ga-DOTATATE, in terms of kinetic constants, were different in different organs. The kinetic parameters of 68Ga-DOTATATE in different organs provide a reference for future dynamic PET imaging.
Collapse
|
8
|
Liu G, Yu H, Shi D, Hu P, Hu Y, Tan H, Zhang Y, Yin H, Shi H. Short-time total-body dynamic PET imaging performance in quantifying the kinetic metrics of 18F-FDG in healthy volunteers. Eur J Nucl Med Mol Imaging 2022; 49:2493-2503. [PMID: 34417855 DOI: 10.1007/s00259-021-05500-2] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2021] [Accepted: 07/18/2021] [Indexed: 02/07/2023]
Abstract
PURPOSE To investigate the performance of short-time dynamic imaging in quantifying kinetic metrics of 2-[18F]-fluoro-2-deoxy-D-glucose (18F-FDG). METHODS Dynamic total-body positron emission tomography (PET) imaging was performed in 11 healthy volunteers for 75 min. The data were divided into 30-, 45- and 75-min groups. Nonlinear regression (NLR) generated constant rates (k1 to k3) and NLR-based Ki in various organs. The Patlak method calculated parametric Ki images to generate Patlak-based Ki values. Paired samples t-test or the Wilcoxon signed-rank test compared the kinetic metrics between the groups, depending on data normality. Deming regression and Bland-Altman analysis assessed the correlation and agreement between NLR- and Patlak-based Ki. A two-sided P < 0.05 was considered statistically significant. RESULTS The 45- and 75-min groups were similar in NLR-based kinetic metrics. The relative difference ranges were as follows: k1, from 3.4% (P = 0.627) in the spleen to 57.9% (P = 0.130) in the white matter; k2, from 6.0% (P = 0.904) in the spleen to 60.7% (P = 0.235) in the left ventricle (LV) myocardium; k3, from 45.6% (P = 0.302) in the LV myocardium to 96.3% (P = 0.478) in the liver; Ki, from 14.0% (P = 0.488) in the liver to 77.8% (P = 0.067) in the kidney. Patlak-based Ki values were also similar between these groups in all organs, except the grey matter (9.6%, P = 0.029) and cerebellum (14.4%, P = 0.002). However, significant differences in kinetic metrics were found between the 30-min and 75-min groups in most organs both in NLR- and Patlak-based analyses. The NLR- and Patlak-based Ki values significantly correlated, with no bias in any of the organs. CONCLUSION Dynamic imaging using a high-sensitivity total-body PET scanner for a shorter time of 45 min could achieve relevant kinetic metrics of 18F-FDG as done by long-time imaging.
Collapse
Affiliation(s)
- Guobing Liu
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, 180 Fenglin Road, Shanghai, 200032, People's Republic of China
- Institute of Nuclear Medicine, Fudan University, Shanghai, 200032, China
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China
- Cancer Prevention and Treatment Center, Zhongshan Hospital, Fudan University, Shanghai, 200032, China
| | - Haojun Yu
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, 180 Fenglin Road, Shanghai, 200032, People's Republic of China
- Institute of Nuclear Medicine, Fudan University, Shanghai, 200032, China
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China
- Cancer Prevention and Treatment Center, Zhongshan Hospital, Fudan University, Shanghai, 200032, China
| | - Dai Shi
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, 180 Fenglin Road, Shanghai, 200032, People's Republic of China
- Institute of Nuclear Medicine, Fudan University, Shanghai, 200032, China
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China
- Cancer Prevention and Treatment Center, Zhongshan Hospital, Fudan University, Shanghai, 200032, China
| | - Pengcheng Hu
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, 180 Fenglin Road, Shanghai, 200032, People's Republic of China
- Institute of Nuclear Medicine, Fudan University, Shanghai, 200032, China
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China
- Cancer Prevention and Treatment Center, Zhongshan Hospital, Fudan University, Shanghai, 200032, China
| | - Yan Hu
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, 180 Fenglin Road, Shanghai, 200032, People's Republic of China
- Institute of Nuclear Medicine, Fudan University, Shanghai, 200032, China
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China
- Cancer Prevention and Treatment Center, Zhongshan Hospital, Fudan University, Shanghai, 200032, China
| | - Hui Tan
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, 180 Fenglin Road, Shanghai, 200032, People's Republic of China
- Institute of Nuclear Medicine, Fudan University, Shanghai, 200032, China
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China
- Cancer Prevention and Treatment Center, Zhongshan Hospital, Fudan University, Shanghai, 200032, China
| | - Yiqiu Zhang
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, 180 Fenglin Road, Shanghai, 200032, People's Republic of China
- Institute of Nuclear Medicine, Fudan University, Shanghai, 200032, China
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China
- Cancer Prevention and Treatment Center, Zhongshan Hospital, Fudan University, Shanghai, 200032, China
| | - Hongyan Yin
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, 180 Fenglin Road, Shanghai, 200032, People's Republic of China
- Institute of Nuclear Medicine, Fudan University, Shanghai, 200032, China
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China
- Cancer Prevention and Treatment Center, Zhongshan Hospital, Fudan University, Shanghai, 200032, China
| | - Hongcheng Shi
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, 180 Fenglin Road, Shanghai, 200032, People's Republic of China.
- Institute of Nuclear Medicine, Fudan University, Shanghai, 200032, China.
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China.
- Cancer Prevention and Treatment Center, Zhongshan Hospital, Fudan University, Shanghai, 200032, China.
| |
Collapse
|
9
|
Driscoll B, Shek T, Vines D, Sun A, Jaffray D, Yeung I. Phantom Validation of a Conservation of Activity-Based Partial Volume Correction Method for Arterial Input Function in Dynamic PET Imaging. Tomography 2022; 8:842-857. [PMID: 35314646 PMCID: PMC8938778 DOI: 10.3390/tomography8020069] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2022] [Revised: 03/10/2022] [Accepted: 03/16/2022] [Indexed: 11/16/2022] Open
Abstract
Dynamic PET (dPET) imaging can be utilized to perform kinetic modelling of various physiologic processes, which are exploited by the constantly expanding range of targeted radiopharmaceuticals. To date, dPET remains primarily in the research realm due to a number of technical challenges, not least of which is addressing partial volume effects (PVE) in the input function. We propose a series of equations for the correction of PVE in the input function and present the results of a validation study, based on a purpose built phantom. 18F-dPET experiments were performed using the phantom on a set of flow tubes representing large arteries, such as the aorta (1" 2.54 cm ID), down to smaller vessels, such as the iliac arteries and veins (1/4" 0.635 cm ID). When applied to the dPET experimental images, the PVE correction equations were able to successfully correct the image-derived input functions by as much as 59 ± 35% in the presence of background, which resulted in image-derived area under the curve (AUC) values within 8 ± 9% of ground truth AUC. The peak heights were similarly well corrected to within 9 ± 10% of the scaled DCE-CT curves. The same equations were then successfully applied to correct patient input functions in the aorta and internal iliac artery/vein. These straightforward algorithms can be applied to dPET images from any PET-CT scanner to restore the input function back to a more clinically representative value, without the need for high-end Time of Flight systems or Point Spread Function correction algorithms.
Collapse
Affiliation(s)
- Brandon Driscoll
- Quantitative Imaging for Personalized Cancer Medicine (QIPCM)—Techna Institute, University Health Network, Toronto, ON M5G 2C4, Canada; (T.S.); (D.J.); (I.Y.)
- Correspondence:
| | - Tina Shek
- Quantitative Imaging for Personalized Cancer Medicine (QIPCM)—Techna Institute, University Health Network, Toronto, ON M5G 2C4, Canada; (T.S.); (D.J.); (I.Y.)
| | - Douglass Vines
- Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, ON M5G 2M9, Canada; (D.V.); (A.S.)
- Department of Radiation Oncology, University of Toronto, Toronto, ON M5T 1P5, Canada
| | - Alex Sun
- Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, ON M5G 2M9, Canada; (D.V.); (A.S.)
- Department of Radiation Oncology, University of Toronto, Toronto, ON M5T 1P5, Canada
| | - David Jaffray
- Quantitative Imaging for Personalized Cancer Medicine (QIPCM)—Techna Institute, University Health Network, Toronto, ON M5G 2C4, Canada; (T.S.); (D.J.); (I.Y.)
- Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, ON M5G 2M9, Canada; (D.V.); (A.S.)
- Department of Radiation Oncology, University of Toronto, Toronto, ON M5T 1P5, Canada
| | - Ivan Yeung
- Quantitative Imaging for Personalized Cancer Medicine (QIPCM)—Techna Institute, University Health Network, Toronto, ON M5G 2C4, Canada; (T.S.); (D.J.); (I.Y.)
- Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, ON M5G 2M9, Canada; (D.V.); (A.S.)
- Department of Radiation Oncology, University of Toronto, Toronto, ON M5T 1P5, Canada
| |
Collapse
|
10
|
Rogasch JMM, Hofheinz F, van Heek L, Voltin CA, Boellaard R, Kobe C. Influences on PET Quantification and Interpretation. Diagnostics (Basel) 2022; 12:diagnostics12020451. [PMID: 35204542 PMCID: PMC8871060 DOI: 10.3390/diagnostics12020451] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2021] [Revised: 01/06/2022] [Accepted: 02/08/2022] [Indexed: 01/21/2023] Open
Abstract
Various factors have been identified that influence quantitative accuracy and image interpretation in positron emission tomography (PET). Through the continuous introduction of new PET technology—both imaging hardware and reconstruction software—into clinical care, we now find ourselves in a transition period in which traditional and new technologies coexist. The effects on the clinical value of PET imaging and its interpretation in routine clinical practice require careful reevaluation. In this review, we provide a comprehensive summary of important factors influencing quantification and interpretation with a focus on recent developments in PET technology. Finally, we discuss the relationship between quantitative accuracy and subjective image interpretation.
Collapse
Affiliation(s)
- Julian M. M. Rogasch
- Department of Nuclear Medicine, Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, 13353 Berlin, Germany;
- Berlin Institute of Health at Charité, Universitätsmedizin Berlin, 10178 Berlin, Germany
| | - Frank Hofheinz
- Institute of Radiopharmaceutical Cancer Research, Helmholtz Center Dresden-Rossendorf, 01328 Dresden, Germany;
| | - Lutz van Heek
- Department of Nuclear Medicine, Faculty of Medicine and University Hospital Cologne, University of Cologne, 50937 Cologne, Germany; (L.v.H.); (C.-A.V.)
| | - Conrad-Amadeus Voltin
- Department of Nuclear Medicine, Faculty of Medicine and University Hospital Cologne, University of Cologne, 50937 Cologne, Germany; (L.v.H.); (C.-A.V.)
| | - Ronald Boellaard
- Department of Radiology and Nuclear Medicine, Cancer Center Amsterdam (CCA), Amsterdam University Medical Center, Free University Amsterdam, 1081 HV Amsterdam, The Netherlands;
| | - Carsten Kobe
- Department of Nuclear Medicine, Faculty of Medicine and University Hospital Cologne, University of Cologne, 50937 Cologne, Germany; (L.v.H.); (C.-A.V.)
- Correspondence: ; Tel.: +49-221-478-7534
| |
Collapse
|
11
|
Ding W, Yu J, Zheng C, Fu P, Huang Q, Feng DD, Yang Z, Wahl RL, Zhou Y. Machine Learning-Based Noninvasive Quantification of Single-Imaging Session Dual-Tracer 18F-FDG and 68Ga-DOTATATE Dynamic PET-CT in Oncology. IEEE TRANSACTIONS ON MEDICAL IMAGING 2022; 41:347-359. [PMID: 34520350 DOI: 10.1109/tmi.2021.3112783] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
68Ga-DOTATATE PET-CT is routinely used for imaging neuroendocrine tumor (NET) somatostatin receptor subtype 2 (SSTR2) density in patients, and is complementary to FDG PET-CT for improving the accuracy of NET detection, characterization, grading, staging, and predicting/monitoring NET responses to treatment. Performing sequential 18F-FDG and 68Ga-DOTATATE PET scans would require 2 or more days and can delay patient care. To align temporal and spatial measurements of 18F-FDG and 68Ga-DOTATATE PET, and to reduce scan time and CT radiation exposure to patients, we propose a single-imaging session dual-tracer dynamic PET acquisition protocol in the study. A recurrent extreme gradient boosting (rXGBoost) machine learning algorithm was proposed to separate the mixed 18F-FDG and 68Ga-DOTATATE time activity curves (TACs) for the region of interest (ROI) based quantification with tracer kinetic modeling. A conventional parallel multi-tracer compartment modeling method was also implemented for reference. Single-scan dual-tracer dynamic PET was simulated from 12 NET patient studies with 18F-FDG and 68Ga-DOTATATE 45-min dynamic PET scans separately obtained within 2 days. Our experimental results suggested an 18F-FDG injection first followed by 68Ga-DOTATATE with a minimum 5 min delayed injection protocol for the separation of mixed 18F-FDG and 68Ga-DOTATATE TACs using rXGBoost algorithm followed by tracer kinetic modeling is highly feasible.
Collapse
|
12
|
Jahn U, Ilan E, Velikyan I, Fröss-Baron K, Lubberink M, Sundin A. Receptor depletion and recovery in small-intestinal neuroendocrine tumors and normal tissues after administration of a single intravenous dose of octreotide measured by 68Ga-DOTATOC PET/CT. EJNMMI Res 2021; 11:118. [PMID: 34822040 PMCID: PMC8617112 DOI: 10.1186/s13550-021-00860-0] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2021] [Accepted: 11/03/2021] [Indexed: 01/04/2023] Open
Abstract
BACKGROUND Low-grade neuroendocrine tumors (NETs) are characterized by an abundance of somatostatin receptors (SSTR) that can be targeted with somatostatin analogs (SSA). When activated with a single dose of SSA, the receptor-ligand complex is internalized, and the receptor is by default recycled within 24 h. Ongoing medication with long-acting SSAs at 68Ga-DOTA-SSA-PET has been shown to increase the tumor-to-normal organ contrast. This study was performed to investigate the time-dependent extended effect (7 h) of a single intravenous dose of 400 µg short-acting octreotide on the tumor versus normal tissue uptake of 68Ga-DOTATOC. METHODS Patients with small-intestinal NETs received a single intravenous dose of 400 µg octreotide and underwent dynamic abdominal 68Ga-DOTATOC-PET/CT at three sessions (0, 3 and 6 h) plus static whole-body (WB) PET/CT (1, 4 and 7 h), starting each PET/CT session by administering 167 ± 21 MBq, 23.5 ± 4.2 µg (mean ± SD, n = 12) of 68Ga-DOTATOC. A previously acquired clinical whole-body 68Ga-DOTATOC scan was used as baseline. SUV and net uptake rate Ki were calculated in tumors, and SUV in healthy organs. RESULTS Tumor SUV decreased significantly from baseline to 1 h post-injection but subsequently increased over time and became similar to baseline at 4 h and 7 h. The tumor net uptake rate, Ki, similarly increased significantly over time and showed a linear correlation both with SUV and tumor-to-blood ratio. By contrast, the uptake in liver, spleen and pancreas remained significantly below baseline levels also at 7 h and the receptor turn-over in tumors thus exceeded that in the normal tissue, with restitution of tumor 68Ga-DOTATOC uptake mainly completed at 7 h. These results however differed depending on tumor size, with significant increases in Ki and SUV between the 1st and 2nd PET, in large tumors (≥ 4 mL) but not in small (> 1 to < 4 mL) tumors. CONCLUSION SSTR recycling is faster in small-intestinal NETs than in liver, spleen and pancreas. This opens the possibility to protect normal tissues during PRRT by administering a single dose of cold peptide hours before peptide receptor radionuclide therapy (PRRT), and most likely additionally improve the availability and uptake of the therapeutic preparation in the tumors.
Collapse
Affiliation(s)
- Ulrika Jahn
- Radiology and Molecular Imaging, Department of Surgical Sciences, Uppsala University, Uppsala, Sweden. .,Uppsala University Hospital, 75185, Uppsala, Sweden.
| | - Ezgi Ilan
- Radiology and Molecular Imaging, Department of Surgical Sciences, Uppsala University, Uppsala, Sweden.,Uppsala University Hospital, 75185, Uppsala, Sweden.,Medical Physics, Uppsala University Hospital, Uppsala, Sweden
| | - Irina Velikyan
- Radiology and Molecular Imaging, Department of Surgical Sciences, Uppsala University, Uppsala, Sweden.,Uppsala University Hospital, 75185, Uppsala, Sweden.,Medical Imaging Centre, Uppsala University Hospital, Uppsala, Sweden
| | - Katarzyna Fröss-Baron
- Radiology and Molecular Imaging, Department of Surgical Sciences, Uppsala University, Uppsala, Sweden.,Uppsala University Hospital, 75185, Uppsala, Sweden.,Medical Imaging Centre, Uppsala University Hospital, Uppsala, Sweden
| | - Mark Lubberink
- Radiology and Molecular Imaging, Department of Surgical Sciences, Uppsala University, Uppsala, Sweden.,Uppsala University Hospital, 75185, Uppsala, Sweden.,Medical Physics, Uppsala University Hospital, Uppsala, Sweden
| | - Anders Sundin
- Radiology and Molecular Imaging, Department of Surgical Sciences, Uppsala University, Uppsala, Sweden.,Uppsala University Hospital, 75185, Uppsala, Sweden.,Medical Imaging Centre, Uppsala University Hospital, Uppsala, Sweden
| |
Collapse
|
13
|
Dimitrakopoulou-Strauss A, Pan L, Sachpekidis C. Parametric Imaging With Dynamic PET for Oncological Applications: Protocols, Interpretation, Current Applications and Limitations for Clinical Use. Semin Nucl Med 2021; 52:312-329. [PMID: 34809877 DOI: 10.1053/j.semnuclmed.2021.10.002] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Nuclear medicine imaging modalities, and in particular positron emission tomography (PET), provide functional images that demonstrate the mean radioactivity distribution at a defined point in time. With the help of mathematical model's, it is possible to depict isolated parameters of the radiotracers' pharmacokinetics and to visualize them. These so called parametric images add a new dimension to the existing conventional PET images and provide more detailed information about the tracer distribution over time and space. Prerequisite for the calculation of parametric images, which reflect specific pharmacokinetic parameters, is the dynamic PET (dPET) data acquisition. Hitherto, PET parametric imaging has mainly found use for research purposes. However, it has not been yet implemented into clinical routine, since it is more time-consuming, it requires a complicated analysis and still lacks a clear benefit over conventional PET imaging. However, the recent introduction of new PET-CT scanners with an ultralong field of view, which allow a faster data acquisition and are associated with higher sensitivity, as well as the development of more sophisticated evaluation software packages will probably lead to a renaissance of dPET and parametric maps even of the whole body. The implementation of dPET imaging in daily routine with appropriate acquisition protocols, as well as the calculation, interpretation and potential clinical applications of parametric images will be discussed in this review article.
Collapse
Affiliation(s)
| | - Leyun Pan
- Clinical Cooperation Unit Nuclear Medicine, German Cancer Research Center, Heidelberg, Germany
| | - Christos Sachpekidis
- Clinical Cooperation Unit Nuclear Medicine, German Cancer Research Center, Heidelberg, Germany
| |
Collapse
|
14
|
Prospective study of dynamic whole-body 68Ga-DOTATOC-PET/CT acquisition in patients with well-differentiated neuroendocrine tumors. Sci Rep 2021; 11:4727. [PMID: 33649421 PMCID: PMC7921579 DOI: 10.1038/s41598-021-83965-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2020] [Accepted: 02/04/2021] [Indexed: 12/04/2022] Open
Abstract
To present the feasibility of a dynamic whole-body (DWB) 68Ga-DOTATOC-PET/CT acquisition in patients with well-differentiated neuroendocrine tumors (WD-NETs). Sixty-one patients who underwent a DWB 68Ga-DOTATOC-PET/CT for a histologically proven/highly suspected WD-NET were prospectively included. The acquisition consisted in single-bed dynamic acquisition centered on the heart, followed by the DWB and static acquisitions. For liver, spleen and tumor (1–5/patient), Ki values (in ml/min/100 ml) were calculated according to Patlak's analysis and tumor-to-liver (TLR-Ki) and tumor-to-spleen ratios (TSR-Ki) were recorded. Ki-based parameters were compared to static parameters (SUVmax/SUVmean, TLR/TSRmean, according to liver/spleen SUVmean), in the whole-cohort and according to the PET system (analog/digital). A correlation analysis between SUVmean/Ki was performed using linear and non-linear regressions. Ki-liver was not influenced by the PET system used, unlike SUVmax/SUVmean. The regression analysis showed a non-linear relation between Ki/SUVmean (R2 = 0.55,0.68 and 0.71 for liver, spleen and tumor uptake, respectively) and a linear relation between TLRmean/TLR-Ki (R2 = 0.75). These results were not affected by the PET system, on the contrary of the relation between TSRmean/TSR-Ki (R2 = 0.94 and 0.73 using linear and non-linear regressions in digital and analog systems, respectively). Our study is the first showing the feasibility of a DWB 68Ga-DOTATOC-PET/CT acquisition in WD-NETs.
Collapse
|
15
|
Advances in Development of Radiometal Labeled Amino Acid-Based Compounds for Cancer Imaging and Diagnostics. Pharmaceuticals (Basel) 2021; 14:ph14020167. [PMID: 33669938 PMCID: PMC7924883 DOI: 10.3390/ph14020167] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2021] [Revised: 02/13/2021] [Accepted: 02/18/2021] [Indexed: 02/08/2023] Open
Abstract
Radiolabeled biomolecules targeted at tumor-specific enzymes, receptors, and transporters in cancer cells represent an intensively investigated and promising class of molecular tools for the cancer diagnosis and therapy. High specificity of such biomolecules is a prerequisite for the treatment with a lower burden to normal cells and for the effective and targeted imaging and diagnosis. Undoubtedly, early detection is a key factor in efficient dealing with many severe tumor types. This review provides an overview and critical evaluation of novel approaches in the designing of target-specific probes labeled with metal radionuclides for the diagnosis of most common death-causing cancers, published mainly within the last three years. Advances are discussed such traditional peptide radiolabeling approaches, and click and nanoparticle chemistry. The progress of radiolabeled peptide based ligands as potential radiopharmaceuticals is illustrated via novel structure and application studies, showing how the molecular modifications reflect their binding selectivity to significant onco-receptors, toxicity, and, by that, practical utilization. The most impressive outputs in categories of newly developed structures, as well as imaging and diagnosis approaches, and the most intensively studied oncological diseases in this context, are emphasized in order to show future perspectives of radiometal labeled amino acid-based compounds in nuclear medicine.
Collapse
|
16
|
Assessment of Lesion Detectability in Dynamic Whole-Body PET Imaging Using Compartmental and Patlak Parametric Mapping. Clin Nucl Med 2020; 45:e221-e231. [PMID: 32108696 DOI: 10.1097/rlu.0000000000002954] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
PURPOSE Hybrid dynamic imaging allows not only the estimation of whole-body (WB) macroparametric maps but also the estimation of microparameters in the initial bed position targeting the blood pool region containing the pathology owing to the limited axial field of view of PET scanners. In this work, we assessed the capability of multipass WB F-FDG PET parametric imaging in terms of lesion detectability through qualitative and quantitative evaluation of simulation and clinical studies. METHODS Simulation studies were conducted by generating data incorporating 3 liver and 3 lung lesions produced by 3 noise levels and 20 noise realizations for each noise level to estimate bias and lesion detection features. The total scan time for the clinical studies of 8 patients addressed for lung and liver lesions staging, including dynamic and static WB imaging, lasted 80 minutes. An in-house-developed MATLAB code was utilized to derive the microparametric and macroparametric maps. We compared lesion detectability and different image-derived PET metrics including the SUVs, Patlak-derived influx rate constant (Ki) and distribution volume (V) and K1, k2, k3, blood volume (bv) microparameters, and Ki estimated using the generalized linear least square approach. RESULTS In total, 104 lesions were detected, among which 47 were located in the targeted blood pool bed position where all quantitative parameters were calculated, thus enabling comparative analysis across all parameters. The evaluation encompassed visual interpretation performed by an expert nuclear medicine specialist and quantitative analysis. High correlation coefficients were observed between SUVmax and Kimax derived from the generalized linear least square approach, as well as Ki generated by Patlak graphical analysis. Moreover, 3 contrast-enhanced CT-proven malignant lesions located in the liver and a biopsy-proven malignant liver lesion not visible on static SUV images and Patlak maps were clearly pinpointed on K1 and k2 maps. CONCLUSIONS Our results demonstrate that full compartmental modeling for the region containing the pathology has the potential of providing complementary information and, in some cases, more accurate diagnosis than conventional static SUV imaging, favorably comparing to Patlak graphical analysis.
Collapse
|
17
|
Lindström E, Lindsjö L, Sundin A, Sörensen J, Lubberink M. Evaluation of block-sequential regularized expectation maximization reconstruction of 68Ga-DOTATOC, 18F-fluoride, and 11C-acetate whole-body examinations acquired on a digital time-of-flight PET/CT scanner. EJNMMI Phys 2020; 7:40. [PMID: 32542512 PMCID: PMC7295929 DOI: 10.1186/s40658-020-00310-1] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2019] [Accepted: 06/01/2020] [Indexed: 01/12/2023] Open
Abstract
Background Block-sequential regularized expectation maximization (BSREM) is a fully convergent iterative image reconstruction algorithm. We hypothesize that tracers with different distribution patterns will result in different optimal settings for the BSREM algorithm. The aim of this study was to evaluate the image quality with variations in the applied β-value and acquisition time for three positron emission tomography (PET) tracers. NEMA image quality phantom measurements and clinical whole-body digital time-of-flight (TOF) PET/computed tomography (CT) examinations with 68Ga-DOTATOC (n = 13), 18F-fluoride (n = 10), and 11C-acetate (n = 13) were included. Each scan was reconstructed using BSREM with β-values of 133, 267, 400, and 533, and ordered subsets expectation maximization (OSEM; 3 iterations, 16 subsets, and 5-mm Gaussian post-processing filter). Both reconstruction methods included TOF and point spread function (PSF) recovery. Quantitative measures of noise, signal-to-noise ratio (SNR), and signal-to-background ratio (SBR) were analysed for various acquisition times per bed position (bp). Results The highest β-value resulted in the lowest level of noise, which in turn resulted in the highest SNR and lowest SBR. Noise levels equal to or lower than those of OSEM were found with β-values equal to or higher than 400, 533, and 267 for 68Ga-DOTATOC, 18F-fluoride, and 11C-acetate, respectively. The specified β-ranges resulted in increased SNR at a minimum of 25% (P < 0.0001) and SBR at a maximum of 23% (P < 0.0001) as compared to OSEM. At a reduced acquisition time by 25% for 68Ga-DOTATOC and 18F-fluoride, and 67% for 11C-acetate, BSREM with β-values equal to or higher than 533 resulted in noise equal to or lower than that of OSEM at full acquisition duration (2 min/bp for 68Ga-DOTATOC and 18F-fluoride, 3 min/bp for 11C-acetate). The reduced acquisition time with β 533 resulted in increased SNR (16–26%, P < 0.003) and SBR (6–18%, P < 0.0001 (P = 0.07 for 11C-acetate)) compared to the full acquisition OSEM. Conclusions Within tracer-specific ranges of β-values, BSREM reconstruction resulted in increased SNR and SBR with respect to conventional OSEM reconstruction. Similar SNR, SBR, and noise levels could be attained with BSREM at relatively shorter acquisition times or, alternatively, lower administered dosages, compared to those attained with OSEM.
Collapse
Affiliation(s)
- Elin Lindström
- Radiology & Nuclear Medicine, Department of Surgical Sciences, Uppsala University, SE-751 85, Uppsala, Sweden. .,Medical Physics, Uppsala University Hospital, SE-751 85, Uppsala, Sweden.
| | - Lars Lindsjö
- PET Centre, Uppsala University Hospital, SE-751 85, Uppsala, Sweden
| | - Anders Sundin
- Radiology & Nuclear Medicine, Department of Surgical Sciences, Uppsala University, SE-751 85, Uppsala, Sweden
| | - Jens Sörensen
- Radiology & Nuclear Medicine, Department of Surgical Sciences, Uppsala University, SE-751 85, Uppsala, Sweden.,PET Centre, Uppsala University Hospital, SE-751 85, Uppsala, Sweden
| | - Mark Lubberink
- Radiology & Nuclear Medicine, Department of Surgical Sciences, Uppsala University, SE-751 85, Uppsala, Sweden.,Medical Physics, Uppsala University Hospital, SE-751 85, Uppsala, Sweden
| |
Collapse
|
18
|
Dimitrakopoulou-Strauss A, Pan L, Sachpekidis C. Kinetic modeling and parametric imaging with dynamic PET for oncological applications: general considerations, current clinical applications, and future perspectives. Eur J Nucl Med Mol Imaging 2020; 48:21-39. [PMID: 32430580 PMCID: PMC7835173 DOI: 10.1007/s00259-020-04843-6] [Citation(s) in RCA: 79] [Impact Index Per Article: 19.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2020] [Accepted: 04/27/2020] [Indexed: 02/07/2023]
Abstract
Dynamic PET (dPET) studies have been used until now primarily within research purposes. Although it is generally accepted that the information provided by dPET is superior to that of conventional static PET acquisitions acquired usually 60 min post injection of the radiotracer, the duration of dynamic protocols, the limited axial field of view (FOV) of current generation clinical PET systems covering a relatively small axial extent of the human body for a dynamic measurement, and the complexity of data evaluation have hampered its implementation into clinical routine. However, the development of new-generation PET/CT scanners with an extended FOV as well as of more sophisticated evaluation software packages that offer better segmentation algorithms, automatic retrieval of the arterial input function, and automatic calculation of parametric imaging, in combination with dedicated shorter dynamic protocols, will facilitate the wider use of dPET. This is expected to aid in oncological diagnostics and therapy assessment. The aim of this review is to present some general considerations about dPET analysis in oncology by means of kinetic modeling, based on compartmental and noncompartmental approaches, and parametric imaging. Moreover, the current clinical applications and future perspectives of the modality are outlined.
Collapse
Affiliation(s)
- Antonia Dimitrakopoulou-Strauss
- Clinical Cooperation Unit Nuclear Medicine, German Cancer Research Center, Im Neuenheimer Feld 280, 69120, Heidelberg, Germany.
| | - Leyun Pan
- Clinical Cooperation Unit Nuclear Medicine, German Cancer Research Center, Im Neuenheimer Feld 280, 69120, Heidelberg, Germany
| | - Christos Sachpekidis
- Clinical Cooperation Unit Nuclear Medicine, German Cancer Research Center, Im Neuenheimer Feld 280, 69120, Heidelberg, Germany
| |
Collapse
|
19
|
Pharmacokinetic analysis of [ 68Ga]Ga-DOTA-TOC PET in meningiomas for assessment of in vivo somatostatin receptor subtype 2. Eur J Nucl Med Mol Imaging 2020; 47:2577-2588. [PMID: 32170347 DOI: 10.1007/s00259-020-04759-1] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2019] [Accepted: 03/04/2020] [Indexed: 01/10/2023]
Abstract
PURPOSE DOTA-D-Phe1-Tyr3-octreotide with gallium-68 ([68Ga]Ga-DOTA-TOC) is one of the PET tracers that forms the basis for peptide receptor radionuclide therapy based on somatostatin receptor subtype 2 (SSTR2) expression in meningiomas. Yet, the quantitative relationship between [68Ga]Ga-DOTA-TOC accumulation and SSTR2 is unknown. We conducted a correlative analysis of a range of [68Ga]Ga-DOTA-TOC PET metric(s) as imaging surrogate(s) of the receptor binding in meningiomas by correlating the PET results with SSTR2 expression from surgical specimens. We additionally investigated possible influences of secondary biological factors such as vascularization, inflammation and proliferation. METHODS Fifteen patients with MRI-presumed or recurrent meningiomas underwent a 60-min dynamic [68Ga]Ga-DOTA-TOC PET/CT before surgery. The PET data comprised maximum and mean standardized uptake values (SUVmax, SUVmean) with and without normalization to reference regions, and quantitative measurements derived from kinetic modelling using a reversible two-tissue compartment model with the fractional blood volume (VB). Expressions of SSTR2 and proliferation (Ki-67, phosphohistone-H3, proliferating cell nuclear antigen) were determined by immunohistochemistry and/or quantitative polymerase chain reaction (qPCR), while biomarkers of vascularization (vascular endothelial growth factor A (VEGFA), endothelial marker CD34) and inflammation (cytokine interleukin-18, microglia/macrophage-specific marker CD68) by qPCR. RESULTS Histopathology revealed 12 World Health Organization (WHO) grade I and three WHO grade II meningiomas showing no link to SSTR2. The majority of [68Ga]Ga-DOTA-TOC PET metrics showed significant associations with SSTR2 protein, while all PET metrics were positively correlated with SSTR2 mRNA with the best results for mean tumour-to-blood ratio (TBRmean) (r = 0.757, P = 0.001) and SUVmean (r = 0.714, P = 0.003). Significant positive correlations were also found between [68Ga]Ga-DOTA-TOC PET metrics, and VEGFA and VB. SSTR2 mRNA was moderately correlated with VEGFA (r = 0.539, P = 0.038). Neither [68Ga]Ga-DOTA-TOC PET metrics nor SSTR2 were correlated with proliferation or inflammation. CONCLUSION [68Ga]Ga-DOTA-TOC accumulation in meningiomas is associated with SSTR2 binding and vascularization with TBRmean being the best PET metric for assessing SSTR2.
Collapse
|
20
|
Lubberink M, Wilking H, Öst A, Ilan E, Sandström M, Andersson C, Fröss-Baron K, Velikyan I, Sundin A. In Vivo Instability of 177Lu-DOTATATE During Peptide Receptor Radionuclide Therapy. J Nucl Med 2020; 61:1337-1340. [PMID: 32005767 DOI: 10.2967/jnumed.119.237818] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2019] [Accepted: 01/03/2020] [Indexed: 12/29/2022] Open
Abstract
Peptide receptor radiotherapy using 177Lu-labeled somatostatin ligand analogs is a well-established treatment for neuroendocrine tumors, with 177Lu-DOTATATE having acquired marketing authorization in Europe and the United States. The investigation of the pharmacokinetics of these radiopharmaceuticals in vivo in humans is crucial for personalized treatment management and understanding of treatment effects. Such an investigation requires input data on the in vivo stability of the radiopharmaceuticals in blood and plasma. The work presented here is devoted to the investigation of the in vivo stability of 177Lu-DOTATATE in humans affected by neuroendocrine tumors. Methods: Blood samples of 6 patients undergoing 177Lu-DOTATATE were taken at 0.5, 4, 24, and 96 h after injection. Analysis of metabolic stability was performed using high-performance liquid chromatography. Results: A fast metabolism of the radiopharmaceutical was observed, with the fraction of intact 177Lu-DOTATATE in plasma decreasing rapidly to 23% ± 5% (mean ± SD) at 24 h and 1.7% ±0. 9% at 96 h after injection. Conclusion: The in vivo stability of 177Lu-DOTATATE is much lower than previously assumed, with the major part of radioactivity in plasma consisting of 177Lu-labeled metabolites already at 24 h after injection.
Collapse
Affiliation(s)
- Mark Lubberink
- Radiology and Nuclear Medicine, Department of Surgical Sciences, Uppsala University, Uppsala, Sweden .,Medical Physics, Uppsala University Hospital, Uppsala, Sweden; and
| | - Helena Wilking
- Medical Imaging Centre, Uppsala University Hospital, Uppsala, Sweden
| | - Amalia Öst
- Medical Imaging Centre, Uppsala University Hospital, Uppsala, Sweden
| | - Ezgi Ilan
- Radiology and Nuclear Medicine, Department of Surgical Sciences, Uppsala University, Uppsala, Sweden.,Medical Physics, Uppsala University Hospital, Uppsala, Sweden; and
| | - Mattias Sandström
- Radiology and Nuclear Medicine, Department of Surgical Sciences, Uppsala University, Uppsala, Sweden.,Medical Physics, Uppsala University Hospital, Uppsala, Sweden; and
| | - Camilla Andersson
- Radiology and Nuclear Medicine, Department of Surgical Sciences, Uppsala University, Uppsala, Sweden
| | - Katarzyna Fröss-Baron
- Radiology and Nuclear Medicine, Department of Surgical Sciences, Uppsala University, Uppsala, Sweden.,Medical Imaging Centre, Uppsala University Hospital, Uppsala, Sweden
| | - Irina Velikyan
- Radiology and Nuclear Medicine, Department of Surgical Sciences, Uppsala University, Uppsala, Sweden.,Medical Imaging Centre, Uppsala University Hospital, Uppsala, Sweden
| | - Anders Sundin
- Radiology and Nuclear Medicine, Department of Surgical Sciences, Uppsala University, Uppsala, Sweden.,Medical Imaging Centre, Uppsala University Hospital, Uppsala, Sweden
| |
Collapse
|
21
|
Ilan E, Velikyan I, Sandström M, Sundin A, Lubberink M. Tumor-to-Blood Ratio for Assessment of Somatostatin Receptor Density in Neuroendocrine Tumors Using 68Ga-DOTATOC and 68Ga-DOTATATE. J Nucl Med 2019; 61:217-221. [PMID: 31302632 DOI: 10.2967/jnumed.119.228072] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2019] [Accepted: 06/18/2019] [Indexed: 11/16/2022] Open
Abstract
PET/CT with 68Ga-DOTA-somatostatin analogs has been tested for therapy monitoring in patients with neuroendocrine tumors (NETs). However, SUVs in tumors do not correlate with the net influx rate (Ki), as a representation of the somatostatin receptor expression. In this study, tumor-to-blood ratio (TBR) was evaluated as an alternative tool for semiquantitative assessment of 68Ga-DOTATOC and 68Ga-DOTATATE tumor uptake and as a therapy monitoring tool for patients with NETs. Methods: Twenty-two NET patients underwent a 45-min dynamic PET/CT scan after injection of 68Ga-DOTATOC or 68Ga-DOTATATE. Ki was determined using the Patlak method, and TBR was calculated for the 40- to 45-min interval. Results: A linear relation was found between Ki and TBR, with a square of Pearson correlation of 0.98 and 0.93 for 68Ga-DOTATOC and 68Ga-DOTATATE, respectively. Conclusion: A high correlation was found between Ki and TBR. Hence, TBR reflects somatostatin receptor density more accurately than SUV and is suggested as the preferred metric for semiquantitative assessment of 68Ga-DOTATOC and 68Ga-DOTATATE tumor uptake.
Collapse
Affiliation(s)
- Ezgi Ilan
- Section of Nuclear Medicine and PET, Department of Surgical Sciences, Uppsala University, Uppsala, Sweden .,Medical Physics, Uppsala University Hospital, Uppsala, Sweden; and
| | - Irina Velikyan
- Section of Nuclear Medicine and PET, Department of Surgical Sciences, Uppsala University, Uppsala, Sweden.,PET Centre, Medical Imaging Centre, Uppsala University Hospital, Uppsala, Sweden
| | - Mattias Sandström
- Section of Nuclear Medicine and PET, Department of Surgical Sciences, Uppsala University, Uppsala, Sweden.,Medical Physics, Uppsala University Hospital, Uppsala, Sweden; and
| | - Anders Sundin
- Section of Nuclear Medicine and PET, Department of Surgical Sciences, Uppsala University, Uppsala, Sweden.,PET Centre, Medical Imaging Centre, Uppsala University Hospital, Uppsala, Sweden
| | - Mark Lubberink
- Section of Nuclear Medicine and PET, Department of Surgical Sciences, Uppsala University, Uppsala, Sweden.,Medical Physics, Uppsala University Hospital, Uppsala, Sweden; and
| |
Collapse
|
22
|
Hallen P, Schug D, Weissler B, Gebhardt P, Salomon A, Kiessling F, Schulz V. PET performance evaluation of the small-animal Hyperion II D PET/MRI insert based on the NEMA NU-4 standard. Biomed Phys Eng Express 2018; 4:065027. [PMID: 30675384 PMCID: PMC6329443 DOI: 10.1088/2057-1976/aae6c2] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2018] [Revised: 10/03/2018] [Accepted: 10/08/2018] [Indexed: 12/23/2022]
Abstract
The Hyperion IID PET insert is the first scanner using fully digital silicon photomultipliers for simultaneous PET/MR imaging of small animals up to rabbit size. In this work, we evaluate the PET performance based on the National Eletrical Manufacturers Association (NEMA) NU 4-2008 standard, whose standardized measurement protocols allow comparison of different small-animal PET scanners. The Hyperion IID small-animal PET/MR insert comprises three rings of 20 detector stacks with pixelated scintillator arrays with a crystal pitch of 1 mm, read out with digital silicon photomultipliers. The scanner has a large ring diameter of 209.6 mm and an axial field of view of 96.7 mm. We evaluated the spatial resolution, energy resolution, time resolution and sensitivity by scanning a 22Na point source. The count rates and scatter fractions were measured for a wide range of 18F activity inside a mouse-sized scatter phantom. We evaluated the image quality using the mouse-sized image quality phantom specified in the NEMA NU4 standard, filled with 18F. Additionally, we verified the in-vivo imaging capabilities by performing a simultaneous PET/MRI scan of a mouse injected with 18F-FDG. We processed all measurement data with an energy window of 250 keV to 625 keV and a coincidence time window of 2 ns. The filtered-backprojection reconstruction of the point source has a full width at half maximum (FWHM) of 1.7 mm near the isocenter and degrades to 2.5 mm at a radial distance of 50 mm. The scanner's average energy resolution is 12.7% (ΔE/E FWHM) and the coincidence resolution time is 609 ps. The peak absolute sensitivity is 4.0% and the true and noise-equivalent count rates reach their peak at an activity of 46 MBq with 483 kcps and 407 kcps, respectively, with a scatter fraction of 13%. The iterative reconstruction of the image quality phantom has a uniformity of 3.7%, and recovery coefficients from 0.29, 0.91 and 0.94 for rod diameters of 1 mm, 3 mm and 5 mm, respectively. After application of scatter and attenuation corrections, the air- and water-filled cold regions have spill-over ratios of 6.3% and 5.4%, respectively. The Hyperion IID PET/MR insert provides state-of-the-art PET performance while enabling simultaneous PET/MRI acquisition of small animals up to rabbit size.
Collapse
Affiliation(s)
- Patrick Hallen
- Department of Physics of Molecular Imaging Systems, Institute for Experimental Molecular Imaging, RWTH Aachen University, Aachen, Germany.,
| | - David Schug
- Department of Physics of Molecular Imaging Systems, Institute for Experimental Molecular Imaging, RWTH Aachen University, Aachen, Germany
| | - Bjoern Weissler
- Department of Physics of Molecular Imaging Systems, Institute for Experimental Molecular Imaging, RWTH Aachen University, Aachen, Germany
| | - Pierre Gebhardt
- Department of Physics of Molecular Imaging Systems, Institute for Experimental Molecular Imaging, RWTH Aachen University, Aachen, Germany
| | - André Salomon
- Department of Oncology Solutions, Philips Research, Eindhoven, Netherlands
| | - Fabian Kiessling
- Institute for Experimental Molecular Imaging, RWTH Aachen University, Aachen, Germany
| | - Volkmar Schulz
- Department of Physics of Molecular Imaging Systems, Institute for Experimental Molecular Imaging, RWTH Aachen University, Aachen, Germany.,Department of Oncology Solutions, Philips Research, Eindhoven, Netherlands
| |
Collapse
|
23
|
Zhuang M, Karakatsanis NA, Dierckx RAJO, Zaidi H. Quantitative Analysis of Heterogeneous [18F]FDG Static (SUV) vs. Patlak (Ki) Whole-body PET Imaging Using Different Segmentation Methods: a Simulation Study. Mol Imaging Biol 2018; 21:317-327. [DOI: 10.1007/s11307-018-1241-8] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|