1
|
Yan S, Qiu R, Wu Z, Luo X, Hu Z, Li J. Individualized dose calculation for internal exposure on radionuclide intake: GPU acceleration approach. Phys Med Biol 2024; 69:175002. [PMID: 39084645 DOI: 10.1088/1361-6560/ad69fa] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2024] [Accepted: 07/31/2024] [Indexed: 08/02/2024]
Abstract
Objective. The rapid and accurate assessment of internal exposure dose is a crucial safeguard for personnel health and safety. This study aims to investigate a precise and efficient GPU Monte Carlo simulation approach for internal exposure dose calculation. It directly calculates doses from common radioactive nuclides intake, like60Co for occupational exposure, allowing personalized assessments.Approach. This study developed a GPU-accelerated Monte Carlo program for internal exposure on radionuclide intake, successfully realizing photoelectronic coupled transport, nuclide simulation, and optimized acceleration. The generation of internal irradiation sources and sampling methods were achieved, along with the establishment of a personalized phantom construction process. Three irradiation scenarios were simulated to assess computational accuracy and efficiency, and to investigate the influence of posture variations on internal dose estimations.Main results. Using the International Commission on Radiological Protection (ICRP) voxel-type phantom, the internal dose of radionuclides in individual organs was calculated, exhibiting relative deviation of less than 3% in comparison to organ dose results interpolated by Specific Absorbed Fractions in ICRP Publication 133. Employing the Chinese reference phantom for calculating internal irradiation dose from the intake of various radionuclides, the use of GPU Monte Carlo program significantly shortened the simulation time compared to using CPU programs, by a factor of 150-500. Internal dose estimation utilizing a seated Chinese phantom revealed up to a 75% maximum difference in organ dose compared to the same phantom in a standing posture.Significance. This study presents a rapid GPU-based simulation method for internal irradiation doses, capable of directly simulating dose outcomes from nuclide intake and accommodating individualized phantoms for more realistic and expeditious calculations tailored to specific internal irradiation scenarios. It provides an effective and feasible tool for precisely calculating internal irradiation doses in real-world scenarios.
Collapse
Affiliation(s)
- Shuchang Yan
- Department of Engineering Physics, Tsinghua University, Beijing , People's Republic of China
- Key Laboratory of Particle & Radiation Imaging, Tsinghua University, Ministry of Education , Beijing, People's Republic of China
| | - Rui Qiu
- Department of Engineering Physics, Tsinghua University, Beijing , People's Republic of China
- Key Laboratory of Particle & Radiation Imaging, Tsinghua University, Ministry of Education , Beijing, People's Republic of China
| | - Zhen Wu
- Department of Engineering Physics, Tsinghua University, Beijing , People's Republic of China
- Key Laboratory of Particle & Radiation Imaging, Tsinghua University, Ministry of Education , Beijing, People's Republic of China
- Nuctech Company Limited , Beijing, People's Republic of China
| | - Xiyu Luo
- Department of Engineering Physics, Tsinghua University, Beijing , People's Republic of China
- Key Laboratory of Particle & Radiation Imaging, Tsinghua University, Ministry of Education , Beijing, People's Republic of China
| | - Ziyi Hu
- Department of Engineering Physics, Tsinghua University, Beijing , People's Republic of China
- Key Laboratory of Particle & Radiation Imaging, Tsinghua University, Ministry of Education , Beijing, People's Republic of China
| | - Junli Li
- Department of Engineering Physics, Tsinghua University, Beijing , People's Republic of China
- Key Laboratory of Particle & Radiation Imaging, Tsinghua University, Ministry of Education , Beijing, People's Republic of China
| |
Collapse
|
2
|
Spink S, Gillett D, Heard S, Harper I, Casey R, Aloj L. Estimation of kidney doses from [ 177Lu]Lu-DOTA-TATE PRRT using single time point post-treatment SPECT/CT. EJNMMI Phys 2024; 11:68. [PMID: 39052172 PMCID: PMC11272758 DOI: 10.1186/s40658-024-00665-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2023] [Accepted: 07/01/2024] [Indexed: 07/27/2024] Open
Abstract
BACKGROUND Dosimetry after [177Lu]Lu-DOTA-TATE therapy can be demanding for both patients and the clinical service due to the need for imaging at several time points. In this work we compare three methods of single time point (STP) kidney dosimetry after [177Lu]Lu-DOTA-TATE therapy with a multiple time point (MTP) dosimetry method. METHOD Method 1 (MTP): Kidney doses were calculated from 31 patients including 107 therapy cycles. Post-therapy SPECT images were acquired on day 0, 4 and 7 along with a CT scan on day 4. A mono-exponential fit was used to calculate kidney doses using cycle specific data. Method 2 (Consistent effective half-life): The effective half-life [Formula: see text] calculated in cycle 1 was assumed consistent for subsequent cycles of therapy and the activity scaled using a single day 3-5 SPECT/CT. Methods 3 and 4 (Hänscheid and Madsen approximations): The Hänscheid approximation and Madsen approximation were both evaluated using a single SPECT/CT acquired on day 0, 4 and 7. All STP methods were compared to the MTP method for accuracy. RESULTS Using the MTP method, mean right and left kidney doses were calculated to be 2.9 ± 1.1 Gy and 2.8 ± 0.9 Gy respectively and the population [Formula: see text] was 56 ± 13 h. For the consistent [Formula: see text], Hänscheid and Madsen methods, the percentage of results within ± 20% of MTP method were 96% (n = 70), 95% (n = 80) and 94% (n = 80) respectively. CONCLUSION All three single time point methods had > 94% of results within ± 20% of the MTP method, however the consistent [Formula: see text] method resulted in the highest alignment with the MTP method and is the only method which allows for calculation of the patient-specific [Formula: see text]. If only a single scan can be performed, day 4 is optimal for kidney dosimetry where the Hänscheid or Madsen approximation can be implemented with good accuracy.
Collapse
Affiliation(s)
- Safia Spink
- Department of Nuclear Medicine, Cambridge University Hospitals NHSFT, Cambridge, UK.
| | - Daniel Gillett
- Department of Nuclear Medicine, Cambridge University Hospitals NHSFT, Cambridge, UK
| | - Sarah Heard
- Department of Nuclear Medicine, Cambridge University Hospitals NHSFT, Cambridge, UK
| | - Ines Harper
- Department of Nuclear Medicine, Cambridge University Hospitals NHSFT, Cambridge, UK
| | - Ruth Casey
- Department of Endocrinology, Cambridge University Hospitals NHSFT, Cambridge, UK
- Department of Genetics, University of Cambridge, Cambridge, UK
| | - Luigi Aloj
- Department of Nuclear Medicine, Cambridge University Hospitals NHSFT, Cambridge, UK
- Department of Radiology, University of Cambridge, Cambridge, UK
| |
Collapse
|
3
|
Song H, Leonio MI, Ferri V, Duan H, Aparici CM, Davidzon G, Franc BL, Moradi F, Shah J, Bergstrom CP, Fan AC, Shah S, Khaki AR, Srinivas S, Iagaru A. Same-day post-therapy imaging with a new generation whole-body digital SPECT/CT in assessing treatment response to [ 177Lu]Lu-PSMA-617 in metastatic castration-resistant prostate cancer. Eur J Nucl Med Mol Imaging 2024; 51:2784-2793. [PMID: 38635050 DOI: 10.1007/s00259-024-06718-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2024] [Accepted: 04/15/2024] [Indexed: 04/19/2024]
Abstract
PURPOSE Lutetium-177 [177Lu]Lu-PSMA-617 radioligand therapy (RLT) represents a significant advancement for metastatic castration-resistant prostate cancer (mCRPC), demonstrating improvements in radiographic progression free survival (rPFS) and overall survival (OS) with a low rate of associated side effects. Currently, most post-therapy SPECT/CT is conducted at 24 h after infusion. This study examines the clinical utility of a next-generation multi-detector Cadmium-Zinc-Telluride (CZT) SPECT/CT system (StarGuide) in same-day post-infusion assessment and early treatment response to [177Lu]Lu-PSMA-617. METHODS In this retrospective study, 68 men with progressive mCRPC treated with [177Lu]Lu-PSMA-617 at our center from June 2022 to June 2023 were evaluated. Digital whole-body SPECT/CT imaging was performed after [177Lu]Lu-PSMA-617infusion (mean ± SD: 1.8 ± 0.6 h, range 1.1-4.9 h). Quantitative analysis of [177Lu]Lu-PSMA-617 positive lesions was performed in patients who underwent at least 2 post-therapy SPECT/CT, using liver parenchyma uptake as reference. Metrics including [177Lu]Lu-PSMA-617 positive total tumor volume (Lu-TTV), SUVmax and SUVmean were calculated. These quantitative metrics on post-infusion SPECT/CT images after cycles 1, 2 and 3 were correlated with overall survival (OS), prostate specific antigen-progression free survival (PSA-PFS) as defined by prostate cancer working group 3 (PCWG3), and PSA decrease over 50% (PSA50) response rates. RESULTS 56 patients (means age 76.2 ± 8.1 years, range: 60-93) who underwent at least 2 post-therapy SPECT/CT were included in the image analysis. The whole-body SPECT/CT scans (~ 12 min per scan) were well tolerated, with 221 same-day scans performed (89%). At a median of 10-months follow-up, 33 (58.9%) patients achieved PSA50 after [177Lu]Lu-PSMA-617 treatment and median PSA-PFS was 5.0 months (range: 1.0-15 months) while median OS was not reached. Quantitative analysis of SPECT/CT images showed that 37 patients (66%) had > 30% reduction in Lu-TTV, associated with significantly improved overall survival (median not reached vs. 6 months, P = 0.008) and PSA-PFS (median 6 months vs. 1 months, P < 0.001). However, changes in SUVmax or SUVmean did not correlate with PSA-PFS or OS. CONCLUSION We successfully implemented same-day post-therapy SPECT/CT after [177Lu]Lu-PSMA-617 infusions. Quantitation of 1-2 h post-therapy SPECT/CT images is a promising method for assessing treatment response. However, the approach is currently limited by its suboptimal detection of small tumor lesions and the necessity of incorporating a third-cycle SPECT/CT to mitigate the effects of any potential treatment-related flare-up. Further investigation in a larger patient cohort and prospective validation is essential to confirm these findings and to explore the role of SPECT/CT as a potential adjunct to PSMA PET/CT in managing mCRPC.
Collapse
Affiliation(s)
- Hong Song
- Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Stanford University, 300 Pasteur Drive, H2200, Stanford, CA, 94305, USA
| | - Maria Isabel Leonio
- Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Stanford University, 300 Pasteur Drive, H2200, Stanford, CA, 94305, USA
| | - Valentina Ferri
- Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Stanford University, 300 Pasteur Drive, H2200, Stanford, CA, 94305, USA
| | - Heying Duan
- Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Stanford University, 300 Pasteur Drive, H2200, Stanford, CA, 94305, USA
| | - Carina Mari Aparici
- Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Stanford University, 300 Pasteur Drive, H2200, Stanford, CA, 94305, USA
| | - Guido Davidzon
- Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Stanford University, 300 Pasteur Drive, H2200, Stanford, CA, 94305, USA
| | - Benjamin L Franc
- Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Stanford University, 300 Pasteur Drive, H2200, Stanford, CA, 94305, USA
| | - Farshad Moradi
- Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Stanford University, 300 Pasteur Drive, H2200, Stanford, CA, 94305, USA
| | - Jagruti Shah
- Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Stanford University, 300 Pasteur Drive, H2200, Stanford, CA, 94305, USA
| | - Colin P Bergstrom
- Department of Medicine, Division of Oncology, Stanford University, Stanford, CA, 94305, USA
| | - Alice C Fan
- Department of Medicine, Division of Oncology, Stanford University, Stanford, CA, 94305, USA
| | - Sumit Shah
- Department of Medicine, Division of Oncology, Stanford University, Stanford, CA, 94305, USA
| | - Ali Raza Khaki
- Department of Medicine, Division of Oncology, Stanford University, Stanford, CA, 94305, USA
| | - Sandy Srinivas
- Department of Medicine, Division of Oncology, Stanford University, Stanford, CA, 94305, USA
| | - Andrei Iagaru
- Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Stanford University, 300 Pasteur Drive, H2200, Stanford, CA, 94305, USA.
| |
Collapse
|
4
|
De Benetti F, Brosch-Lenz J, Guerra González JM, Uribe C, Eiber M, Navab N, Wendler T. DosePatch: physics-inspired cropping layout for patch-based Monte Carlo simulations to provide fast and accurate internal dosimetry. EJNMMI Phys 2024; 11:51. [PMID: 38922372 PMCID: PMC11208390 DOI: 10.1186/s40658-024-00646-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2023] [Accepted: 05/08/2024] [Indexed: 06/27/2024] Open
Abstract
BACKGROUND Dosimetry-based personalized therapy was shown to have clinical benefits e.g. in liver selective internal radiation therapy (SIRT). Yet, there is no consensus about its introduction into clinical practice, mainly as Monte Carlo simulations (gold standard for dosimetry) involve massive computation time. We addressed the problem of computation time and tested a patch-based approach for Monte Carlo simulations for internal dosimetry to improve parallelization. We introduce a physics-inspired cropping layout for patch-based MC dosimetry, and compare it to cropping layouts of the literature as well as dosimetry using organ-S-values, and dose kernels, taking whole-body Monte Carlo simulations as ground truth. This was evaluated in five patients receiving Yttrium-90 liver SIRT. RESULTS The patch-based Monte Carlo approach yielded the closest results to the ground truth, making it a valid alternative to the conventional approach. Our physics-inspired cropping layout and mosaicking scheme yielded a voxel-wise error of < 2% compared to whole-body Monte Carlo in soft tissue, while requiring only ≈ 10% of the time. CONCLUSIONS This work demonstrates the feasibility and accuracy of physics-inspired cropping layouts for patch-based Monte Carlo simulations.
Collapse
Affiliation(s)
- Francesca De Benetti
- Chair for Computer Aided Medical Procedures and Augmented Reality, Technical University of Munich, Garching, Germany
| | - Julia Brosch-Lenz
- Department of Nuclear Medicine, Klinikum Rechts der Isar, Technical University of Munich, Munich, Germany
| | - Jorge Mario Guerra González
- Chair for Computer Aided Medical Procedures and Augmented Reality, Technical University of Munich, Garching, Germany
| | - Carlos Uribe
- Department of Integrative Oncology, BC Cancer Research Institute, Vancouver, Canada
| | - Matthias Eiber
- Department of Nuclear Medicine, Klinikum Rechts der Isar, Technical University of Munich, Munich, Germany
| | - Nassir Navab
- Chair for Computer Aided Medical Procedures and Augmented Reality, Technical University of Munich, Garching, Germany
| | - Thomas Wendler
- Chair for Computer Aided Medical Procedures and Augmented Reality, Technical University of Munich, Garching, Germany.
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Augsburg, Augsburg, Germany.
- Institute of Digital Medicine, University Hospital Augsburg, Neusaess, Germany.
- Clinical Computational Medical Imaging Research, University of Augsburg, Augsburg, Germany.
| |
Collapse
|
5
|
Lawless M, Byrns K, Bednarz BP, Meudt J, Shanmuganayagam D, Shah J, McMillan A, Li K, Pirasteh A, Miller J. Feasibility of identifying proliferative active bone marrow with fat fraction MRI and multi-energy CT. Phys Med Biol 2024; 69:135007. [PMID: 38876111 DOI: 10.1088/1361-6560/ad58a0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2024] [Accepted: 06/14/2024] [Indexed: 06/16/2024]
Abstract
Objective.Active bone marrow (ABM) can serve as both an organ at risk and a target in external beam radiotherapy.18F-fluorothymidine (FLT) PET is the current gold standard for identifying proliferative ABM but it is not approved for human use, and PET scanners are not always available to radiotherapy clinics. Identifying ABM through other, more accessible imaging modalities will allow more patients to receive treatment specific to their ABM distribution. Multi-energy CT (MECT) and fat-fraction MRI (FFMRI) show promise in their ability to characterize bone marrow adiposity, but these methods require validation for identifying proliferative ABM.Approach.Six swine subjects were imaged using FFMRI, fast-kVp switching (FKS) MECT and sequential-scanning (SS) MECT to identify ABM volumes relative to FLT PET-derived ABM volumes. ABM was contoured on FLT PET images as the region within the bone marrow with a SUV above the mean. Bone marrow was then contoured on the FFMRI and MECT images, and thresholds were applied within these contours to determine which threshold produced the best agreement with the FLT PET determined ABM contour. Agreement between contours was measured using the Dice similarity coefficient (DSC).Main results.FFMRI produced the best estimate of the PET ABM contour. Compared to FLT PET ABM volumes, the FFMRI, SS MECT and FKS MECT ABM contours produced average peak DSC of 0.722 ± 0.080, 0.619 ± 0.070, and 0.464 ± 0.080, respectively. The ABM volume was overestimated by 40.51%, 97.63%, and 140.13% by FFMRI, SS MECT and FKS MECT, respectively.Significance.This study explored the ability of FFMRI and MECT to identify the proliferative relative to ABM defined by FLT PET. Of the methods investigated, FFMRI emerged as the most accurate approximation to FLT PET-derived active marrow contour, demonstrating superior performance by both DSC and volume comparison metrics. Both FFMRI and SS MECT show promise for providing patient-specific ABM treatments.
Collapse
Affiliation(s)
- M Lawless
- Department of Human Oncology, University of Wisconsin-Madison, 600 Highland Ave, Madison, WI 53792, United States of America
| | - K Byrns
- St. Lukes Radiation Oncology Associates, 915 E 1st St, Duluth, MN 55805, United States of America
| | - B P Bednarz
- Department of Medical Physics, University of Wisconsin-Madison, 1111 Highland Ave, Madison, WI 53705, United States of America
| | - J Meudt
- Department of Animal and Dairy Sciences, University of Wisconsin-Madison, 1675 Observatory Drive, Madison, WI 53706, United States of America
| | - D Shanmuganayagam
- Department of Animal and Dairy Sciences, University of Wisconsin-Madison, 1675 Observatory Drive, Madison, WI 53706, United States of America
| | - J Shah
- Siemens Healthineers, 221 Gregson Dr, Cary, NC 27511, United States of America
| | - A McMillan
- Department of Radiology, University of Wisconsin-Madison, 600 Highland Ave, Madison, WI 53792, United States of America
| | - K Li
- Department of Medical Physics, University of Wisconsin-Madison, 1111 Highland Ave, Madison, WI 53705, United States of America
| | - A Pirasteh
- Department of Radiology, University of Wisconsin-Madison, 600 Highland Ave, Madison, WI 53792, United States of America
| | - J Miller
- Department of Human Oncology, University of Wisconsin-Madison, 600 Highland Ave, Madison, WI 53792, United States of America
| |
Collapse
|
6
|
Zanzonico P. The MIRD Schema for Radiopharmaceutical Dosimetry: A Review. J Nucl Med Technol 2024; 52:74-85. [PMID: 38839128 DOI: 10.2967/jnmt.123.265668] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2023] [Revised: 01/20/2024] [Indexed: 06/07/2024] Open
Abstract
Internal dosimetry evaluates the amount and spatial and temporal distributions of radiation energy deposited in tissue from radionuclides within the body. Historically, nuclear medicine had been largely a diagnostic specialty, and the implicitly performed risk-benefit analyses have been straightforward, with relatively low administered activities yielding important diagnostic information whose benefit far outweighs any potential risk associated with the attendant normal-tissue radiation doses. Although dose estimates based on anatomic models and population-average kinetics in this setting may deviate rather significantly from the actual normal-organ doses for individual patients, the large benefit-to-risk ratios are very forgiving of any such inaccuracies. It is in this context that the MIRD schema was originally developed and has been largely applied. The MIRD schema, created and maintained by the MIRD committee of the Society of Nuclear Medicine and Molecular Imaging, comprises the notation, terminology, mathematic formulas, and reference data for calculating tissue radiation doses from radiopharmaceuticals administered to patients. However, with the ongoing development of new radiopharmaceuticals and the increasing therapeutic application of such agents, internal dosimetry in nuclear medicine and the MIRD schema continue to evolve-from population-average and organ-level to patient-specific and suborgan to voxel-level to cell-level dose estimation. This article will review the basic MIRD schema, relevant quantities and units, reference anatomic models, and its adaptation to small-scale and patient-specific dosimetry.
Collapse
Affiliation(s)
- Pat Zanzonico
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York
| |
Collapse
|
7
|
George SC, Tolakanahalli R, Aguirre S, Kim TP, Samuel EJJ, Mishra V. A single-institution experience with 177Lu RPT workflow improvements and qualifying the SPECT/CT imaging for dosimetry. Front Oncol 2024; 14:1331266. [PMID: 38469241 PMCID: PMC10925616 DOI: 10.3389/fonc.2024.1331266] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2023] [Accepted: 01/22/2024] [Indexed: 03/13/2024] Open
Abstract
Background and purpose Implementing any radiopharmaceutical therapy (RPT) program requires a comprehensive review of system readiness, appropriate workflows, and training to ensure safe and efficient treatment delivery. A quantitative assessment of the dose delivered to targets and organs at risk (OAR) using RPT is possible by correlating the absorbed doses with the delivered radioactivity. Integrating dosimetry into an established RPT program demands a thorough analysis of the necessary components and system fine-tuning. This study aims to report an optimized workflow for molecular radiation therapy using 177Lu with a primary focus on integrating patient-specific dosimetry into an established radiopharmaceutical program in a radiation oncology setting. Materials and methods We comprehensively reviewed using the Plan-Do-Check-Act (PDCA) cycle, including efficacy and accuracy of delivery and all aspects of radiation safety of the RPT program. The GE Discovery SPECT/CT 670DR™ system was calibrated per MIM protocol for dose calculation on MIM SurePlan™ MRT software. Jaszcak Phantom with 15-20 mCi of 177Lu DOTATATE with 2.5 µM EDTA solution was used, with the main energy window defined as 208 keV ±10% (187.6 to 229.2 keV); the upper scatter energy window was set to 240 keV ±5% (228 to 252 keV), while the lower scatter energy window was 177.8 keV ±5% (168.9 to 186.7 keV). Volumetric quality control tests and adjustments were performed to ensure the correct alignment of the table, NM, and CT gantry on SPECT/CT. A comprehensive end-to-end (E2E) test was performed to ensure workflow, functionality, and quantitative dose accuracy. Results Workflow improvements and checklists are presented after systematically analyzing over 400 administrations of 177Lu-based RPT. Injected activity to each sphere in the NEMA Phantom scan was quantified, and the MIM Sureplan MRT reconstruction images calculated activities within ±12% of the injected activity. Image alignment tests on the SPECT/CT showed a discrepancy of more than the maximum tolerance of 2.2 mm on any individual axis. As a result of servicing the machine and updating the VQC and COR corrections, the hybrid imaging system was adjusted to achieve an accuracy of <1 mm in all directions. Conclusion Workflows and checklists, after analysis of system readiness and adequate training for staff and patients, are presented. Hardware and software components for patient-specific dosimetry are presented with a focus on hybrid image registration and correcting any errors that affect dosimetric quantification calculation. Moreover, this manuscript briefly overviews the necessary quality assurance requirements for converting diagnostic images into dosimetry measurement tools and integrating dosimetry for RPT based on 177Lu.
Collapse
Affiliation(s)
- Siju C. George
- Department of Radiation Oncology, Miami Cancer Institute, Baptist Health, Miami, FL, United States
- Department of Physics, School of Advanced Sciences, Vellore Institute of Technology, Vellore, India
| | - Ranjini Tolakanahalli
- Department of Radiation Oncology, Miami Cancer Institute, Baptist Health, Miami, FL, United States
| | - Santiago Aguirre
- Department of Radiation Oncology, Miami Cancer Institute, Baptist Health, Miami, FL, United States
| | - Taehyung Peter Kim
- Department of Radiation Oncology, Miami Cancer Institute, Baptist Health, Miami, FL, United States
| | | | - Vivek Mishra
- Department of Radiation Oncology, Miami Cancer Institute, Baptist Health, Miami, FL, United States
| |
Collapse
|
8
|
Vernekar S, Budha RR, Alavala RR. Radiopharmaceuticals: A New Vista for Diagnosis and Treatment of Thyroid Cancer. Curr Radiopharm 2024; 17:148-162. [PMID: 38213166 DOI: 10.2174/0118744710277275231112081003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2023] [Revised: 09/26/2023] [Accepted: 10/02/2023] [Indexed: 01/13/2024]
Abstract
Radiopharmaceuticals are in the diagnosis and treatment of cancerous and noncancerous diseases, and a hope for optimistic effort in the field of nuclear medicine. They play a crucial role in clinical nuclear medicine by providing a tool to comprehend human disease and create efficient treatments. A detailed analysis is provided regarding the crux of molecular imaging including PET and SPECT overview for the detection of cancers. For a specified understanding of radiation therapy, topics include ranging from the selection of radionuclide to its development and manufacture, and dosage requirements to establishing the importance of I- 131 Radiotherapy in thyroid cancer. In this review, we also discussed the current state of the art of nuclear medicine in thyroid cancer, including the role of radioiodine (RAI) therapeutic scans in the diagnosis of differentiated thyroid cancer. In addition, we established a brief outlook into the current status of the research in thyroid cancer and discussed the future directions in this field.
Collapse
Affiliation(s)
- Siddhi Vernekar
- Shobhaben Pratapbhai Patel School of Pharmacy & Technology Management, SVKM's NMIMS, V.L. Mehta Road, Vile Parle (W), Mumbai, 400056, India
| | - Roja Rani Budha
- Amity Institute of Pharmacy, Amity University, Panvel, Mumbai, Maharashtra, 410206, India
| | - Rajasekhar Reddy Alavala
- Shobhaben Pratapbhai Patel School of Pharmacy & Technology Management, SVKM's NMIMS, V.L. Mehta Road, Vile Parle (W), Mumbai, 400056, India
| |
Collapse
|
9
|
Bensiali M, Anizan N, Leboulleux S, Lamart S, Davesne E, Broggio D, Desbrée A, Franck D. Patient-specific biokinetics and hybrid 2D/3D approach integration in OEDIPE software: Application to radioiodine therapy. Phys Med 2023; 113:102462. [PMID: 36424255 DOI: 10.1016/j.ejmp.2022.09.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/08/2022] [Revised: 09/08/2022] [Accepted: 09/27/2022] [Indexed: 11/23/2022] Open
Abstract
BACKGROUND The progression of targeted radionuclide therapy requires the development of dosimetry software accounting for patient-specific biokinetics. New functionalities were thus developed in the OEDIPE software, to deal with multiple 3D images or multiple planar images and a SPECT image. MATERIEL & METHOD Methods were implemented to recover patient biokinetics in volumes of interest. If several 3D SPECT images are available, they are registered to a reference CT scan. When several planar images and a single SPECT are available, the planar images are registered to the SPECT and counts of the planar images converted to activity. To validate these developments, six SPECT/CT and planar images of a Jaszczak phantom containing I-131 were acquired at different dates. Cumulated activity was estimated in each sphere using the SPECT/CT images only or the planar series associated to one SPECT/CT. Biokinetics and doses in lesions and in the lungs of a patient treated with I-131 for differentiated thyroid cancer were then estimated using four planar images and a SPECT/CT scan. Whole-body retention data were used to compare the biokinetics obtained from the planar and SPECT data. RESULTS Activities and cumulated activities estimated using OEDIPE in the phantom spheres agreed well with the reference values for both approaches. Results obtained for the patient compared well with those derived from whole-body retention data. CONCLUSION The implemented features allow automatic evaluation of patient-specific biokinetics from different series of patient images, enabling patient-specific dosimetry without the need for external software to estimate the cumulated activities in different VOIs.
Collapse
Affiliation(s)
- M Bensiali
- Laboratoire d'Évaluation de la Dose Interne, Institut de Radioprotection et de Sûreté Nucléaire, IRSN/PSE-SANTE/SDOS/LEDI, Fontenay-aux-Roses, France
| | - N Anizan
- Gustave Roussy and Université Paris-Saclay, Medical Physics Department, Villejuif, France; Gustave Roussy and Université Paris-Saclay, Nuclear Medicine Department, Villejuif, France
| | - S Leboulleux
- Gustave Roussy and Université Paris-Saclay, Nuclear Medicine Department, Villejuif, France
| | - S Lamart
- Laboratoire d'Évaluation de la Dose Interne, Institut de Radioprotection et de Sûreté Nucléaire, IRSN/PSE-SANTE/SDOS/LEDI, Fontenay-aux-Roses, France.
| | - E Davesne
- Laboratoire d'Évaluation de la Dose Interne, Institut de Radioprotection et de Sûreté Nucléaire, IRSN/PSE-SANTE/SDOS/LEDI, Fontenay-aux-Roses, France; Laboratoire Radioprotection et Santé, Commissariat à l'Energie Atomique et aux Energies Alternatives, INSTN/UES/LRS, Gif-sur-Yvette, France
| | - D Broggio
- Laboratoire d'Évaluation de la Dose Interne, Institut de Radioprotection et de Sûreté Nucléaire, IRSN/PSE-SANTE/SDOS/LEDI, Fontenay-aux-Roses, France
| | - A Desbrée
- Laboratoire d'Évaluation de la Dose Interne, Institut de Radioprotection et de Sûreté Nucléaire, IRSN/PSE-SANTE/SDOS/LEDI, Fontenay-aux-Roses, France
| | - D Franck
- Laboratoire d'Évaluation de la Dose Interne, Institut de Radioprotection et de Sûreté Nucléaire, IRSN/PSE-SANTE/SDOS/LEDI, Fontenay-aux-Roses, France
| |
Collapse
|
10
|
George SC, Samuel EJJ. Developments in 177Lu-based radiopharmaceutical therapy and dosimetry. Front Chem 2023; 11:1218670. [PMID: 37583569 PMCID: PMC10424930 DOI: 10.3389/fchem.2023.1218670] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2023] [Accepted: 06/27/2023] [Indexed: 08/17/2023] Open
Abstract
177Lu is a radioisotope that has become increasingly popular as a therapeutic agent for treating various conditions, including neuroendocrine tumors and metastatic prostate cancer. 177Lu-tagged radioligands are molecules precisely designed to target and bind to specific receptors or proteins characteristic of targeted cancer. This review paper will present an overview of the available 177Lu-labelled radioligands currently used to treat patients. Based on recurring, active, and completed clinical trials and other available literature, we evaluate current status, interests, and developments in assessing patient-specific dosimetry, which will define the future of this particular treatment modality. In addition, we will discuss the challenges and opportunities of the existing dosimetry standards to measure and calculate the radiation dose delivered to patients, which is essential for ensuring treatments' safety and efficacy. Finally, this article intends to provide an overview of the current state of 177Lu- tagged radioligand therapy and highlight the areas where further research can improve patient treatment outcomes.
Collapse
Affiliation(s)
- Siju C. George
- Radiation Oncology Department, Miami Cancer Institute, Baptist Health, Miami, FL, United States
- Department of Physics, School of Advanced Sciences, Vellore Institute of Technology, Vellore, India
| | | |
Collapse
|
11
|
Kesner AL, Carter LM, Ramos JCO, Lafontaine D, Olguin EA, Brown JL, President B, Jokisch DW, Fisher DR, Bolch WE. MIRD Pamphlet No. 28, Part 1: MIRDcalc-A Software Tool for Medical Internal Radiation Dosimetry. J Nucl Med 2023; 64:1117-1124. [PMID: 37268428 PMCID: PMC10315701 DOI: 10.2967/jnumed.122.264225] [Citation(s) in RCA: 12] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2022] [Revised: 03/21/2023] [Indexed: 06/04/2023] Open
Abstract
Medical internal radiation dosimetry constitutes a fundamental aspect of diagnosis, treatment, optimization, and safety in nuclear medicine. The MIRD committee of the Society of Nuclear Medicine and Medical Imaging developed a new computational tool to support organ-level and suborgan tissue dosimetry (MIRDcalc, version 1). Based on a standard Excel spreadsheet platform, MIRDcalc provides enhanced capabilities to facilitate radiopharmaceutical internal dosimetry. This new computational tool implements the well-established MIRD schema for internal dosimetry. The spreadsheet incorporates a significantly enhanced database comprising details for 333 radionuclides, 12 phantom reference models (International Commission on Radiological Protection), 81 source regions, and 48 target regions, along with the ability to interpolate between models for patient-specific dosimetry. The software also includes sphere models of various composition for tumor dosimetry. MIRDcalc offers several noteworthy features for organ-level dosimetry, including modeling of blood source regions and dynamic source regions defined by user input, integration of tumor tissues, error propagation, quality control checks, batch processing, and report-preparation capabilities. MIRDcalc implements an immediate, easy-to-use single-screen interface. The MIRDcalc software is available for free download (www.mirdsoft.org) and has been approved by the Society of Nuclear Medicine and Molecular Imaging.
Collapse
Affiliation(s)
- Adam L Kesner
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York;
| | - Lukas M Carter
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York
| | - Juan C Ocampo Ramos
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York
| | - Daniel Lafontaine
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York
| | - Edmond A Olguin
- Beth Israel Deaconess Medical Center, Department of Radiology, Harvard Medical School, Boston, Massachusetts
| | - Justin L Brown
- J. Crayton Pruitt Department of Biomedical Engineering, University of Florida, Gainesville, Florida
| | - Bonnie President
- J. Crayton Pruitt Department of Biomedical Engineering, University of Florida, Gainesville, Florida
| | - Derek W Jokisch
- Department of Physics and Engineering, Francis Marion University, Florence, South Carolina
- Center for Radiation Protection Knowledge, Oak Ridge National Laboratory, Oak Ridge, Tennessee; and
| | - Darrell R Fisher
- University of Washington and Versant Medical Physics and Radiation Safety, Richland, Washington
| | - Wesley E Bolch
- J. Crayton Pruitt Department of Biomedical Engineering, University of Florida, Gainesville, Florida
| |
Collapse
|
12
|
Song H, Ferri V, Duan H, Aparici CM, Davidzon G, Franc BL, Moradi F, Nguyen J, Shah J, Iagaru A. SPECT at the speed of PET: a feasibility study of CZT-based whole-body SPECT/CT in the post 177Lu-DOTATATE and 177Lu-PSMA617 setting. Eur J Nucl Med Mol Imaging 2023; 50:2250-2257. [PMID: 36869177 DOI: 10.1007/s00259-023-06176-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2022] [Accepted: 01/21/2023] [Indexed: 03/05/2023]
Abstract
PURPOSE To evaluate the feasibility of using the StarGuide (General Electric Healthcare, Haifa, Israel), a new generation multi-detector cadmium-zinc-telluride (CZT)-based SPECT/CT, for whole-body imaging in the setting of post-therapy imaging of 177Lu-labeled radiopharmaceuticals. METHODS Thirty-one patients (34-89 years old; mean ± SD, 65.5 ± 12.1) who were treated with either 177Lu-DOTATATE (n=17) or 177Lu-PSMA617 (n=14) as part of standard of care were scanned post-therapy with the StarGuide; some were also scanned with the standard GE Discovery 670 Pro SPECT/CT. All patients had either 64Cu-DOTATATE or 18F-DCFPyL PET/CT prior to first cycle of therapy for eligibility check. The detection/targeting rate (lesion uptake greater than blood pool uptake) of large lesions meeting RECIST 1.1 size criteria on post-therapy StarGuide SPECT/CT was evaluated and compared to the standard design GE Discovery 670 Pro SPECT/CT (when available) and pre-therapy PET by two nuclear medicine physicians with consensus read. RESULTS This retrospective analysis identified a total of 50 post-therapy scans performed with the new imaging protocol from November 2021 to August 2022. The StarGuide system acquired vertex to mid-thighs post-therapy SPECT/CT scans with 4 bed positions, 3 min/bed and a total scan time of 12 min. In comparison, the standard GE Discovery 670 Pro SPECT/CT system typically acquires images in 2 bed positions covering the chest, abdomen, and pelvis with a total scan time of 32 min. The pre-therapy 64Cu-DOTATATE PET takes 20 min with 4 bed positions on GE Discovery MI PET/CT, and 18F-DCFPyL PET takes 8-10 min with 4-5 bed positions on GE Discovery MI PET/CT. This preliminary evaluation showed that the post-therapy scans acquired with faster scanning time using StarGuide system had comparable detection/targeting rate compared to the Discovery 670 Pro SPECT/CT system and detected large lesions defined by RECIST criteria on the pre-therapy PET scans. CONCLUSION Fast acquisition of whole-body post-therapy SPECT/CT is feasible with the new StarGuide system. Short scanning time improves the patients' clinical experience and compliance which may lead to increased adoption of post-therapy SPECT. This opens the possibility to offer imaged-based treatment response assessment and personalized dosimetry to patients referred for targeted radionuclide therapies.
Collapse
Affiliation(s)
- Hong Song
- Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Stanford University, 300 Pasteur Drive, H2200, Stanford, CA, 94305, USA
| | - Valentina Ferri
- Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Stanford University, 300 Pasteur Drive, H2200, Stanford, CA, 94305, USA
| | - Heying Duan
- Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Stanford University, 300 Pasteur Drive, H2200, Stanford, CA, 94305, USA
| | - Carina Mari Aparici
- Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Stanford University, 300 Pasteur Drive, H2200, Stanford, CA, 94305, USA
| | - Guido Davidzon
- Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Stanford University, 300 Pasteur Drive, H2200, Stanford, CA, 94305, USA
| | - Benjamin L Franc
- Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Stanford University, 300 Pasteur Drive, H2200, Stanford, CA, 94305, USA
| | - Farshad Moradi
- Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Stanford University, 300 Pasteur Drive, H2200, Stanford, CA, 94305, USA
| | - Judy Nguyen
- Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Stanford University, 300 Pasteur Drive, H2200, Stanford, CA, 94305, USA
| | - Jagruti Shah
- Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Stanford University, 300 Pasteur Drive, H2200, Stanford, CA, 94305, USA
| | - Andrei Iagaru
- Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Stanford University, 300 Pasteur Drive, H2200, Stanford, CA, 94305, USA.
| |
Collapse
|
13
|
Brosch-Lenz J, Ke S, Wang H, Frey E, Dewaraja YK, Sunderland J, Uribe C. An International Study of Factors Affecting Variability of Dosimetry Calculations, Part 2: Overall Variabilities in Absorbed Dose. J Nucl Med 2023; 64:1109-1116. [PMID: 37024302 PMCID: PMC10315703 DOI: 10.2967/jnumed.122.265094] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2022] [Revised: 02/07/2023] [Accepted: 02/07/2023] [Indexed: 04/08/2023] Open
Abstract
Dosimetry for personalized radiopharmaceutical therapy has gained considerable attention. Many methods, tools, and workflows have been developed to estimate absorbed dose (AD). However, standardization is still required to reduce variability of AD estimates across centers. One effort for standardization is the Society of Nuclear Medicine and Molecular Imaging 177Lu Dosimetry Challenge, which comprised 5 tasks (T1-T5) designed to assess dose estimate variability associated with the imaging protocol (T1 vs. T2 vs. T3), segmentation (T1 vs. T4), time integration (T4 vs. T5), and dose calculation (T5) steps of the dosimetry workflow. The aim of this work was to assess the overall variability in AD calculations for the different tasks. Methods: Anonymized datasets consisting of serial planar and quantitative SPECT/CT scans, organ and lesion contours, and time-integrated activity maps of 2 patients treated with 177Lu-DOTATATE were made available globally for participants to perform dosimetry calculations and submit their results in standardized submission spreadsheets. The data were carefully curated for formal mistakes and methodologic errors. General descriptive statistics for ADs were calculated, and statistical analysis was performed to compare the results of different tasks. Variability in ADs was measured using the quartile coefficient of dispersion. Results: ADs to organs estimated from planar imaging protocols (T2) were lower by about 60% than those from pure SPECT/CT (T1), and the differences were statistically significant. Importantly, the average differences in dose estimates when at least 1 SPECT/CT acquisition was available (T1, T3, T4, T5) were within ±10%, and the differences with respect to T1 were not statistically significant for most organs and lesions. When serial SPECT/CT images were used, the quartile coefficients of dispersion of ADs for organs and lesions were on average less than 20% and 26%, respectively, for T1; 20% and 18%, respectively, for T4 (segmentations provided); and 10% and 5%, respectively, for T5 (segmentation and time-integrated activity images provided). Conclusion: Variability in ADs was reduced as segmentation and time-integration data were provided to participants. Our results suggest that SPECT/CT-based imaging protocols generate more consistent and less variable results than planar imaging methods. Effort at standardizing segmentation and fitting should be made, as this may substantially reduce variability in ADs.
Collapse
Affiliation(s)
- Julia Brosch-Lenz
- Department of Integrative Oncology, BC Cancer Research Institute, Vancouver, British Columbia, Canada
| | - Suqi Ke
- Division of Quantitative Sciences, Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins University School of Medicine, Baltimore, Maryland
| | - Hao Wang
- Division of Quantitative Sciences, Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins University School of Medicine, Baltimore, Maryland
| | - Eric Frey
- Rapid, LLC, Baltimore, Maryland
- Department of Radiology, Johns Hopkins University, Baltimore, Maryland
| | - Yuni K Dewaraja
- Department of Radiology, University of Michigan, Ann Arbor, Michigan
| | - John Sunderland
- Department of Radiology, University of Iowa, Iowa City, Iowa
| | - Carlos Uribe
- Department of Integrative Oncology, BC Cancer Research Institute, Vancouver, British Columbia, Canada;
- Department of Functional Imaging, BC Cancer, Vancouver, British Columbia, Canada; and
- Department of Radiology, University of British Columbia, Vancouver, British Columbia, Canada
| |
Collapse
|
14
|
Adam DP, Hammer C, Malyshev JZ, Culberson WS, Bradshaw TJ, Grudzinski JJ, Harari PM, Bednarz BP. Creation of waterproof, TLD probes for dose measurements to validate image-based radiopharmaceutical therapy dosimetry workflow. Biomed Phys Eng Express 2023; 9:10.1088/2057-1976/accf22. [PMID: 37084718 PMCID: PMC11186108 DOI: 10.1088/2057-1976/accf22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2023] [Accepted: 04/21/2023] [Indexed: 04/23/2023]
Abstract
Voxel-level dosimetry based on nuclear medicine images offers patient-specific personalization of radiopharmaceutical therapy (RPT) treatments. Clinical evidence is emerging demonstrating improvements in treatment precision in patients when voxel-level dosimetry is used compared to MIRD. Voxel-level dosimetry requires absolute quantification of activity concentrations in the patient, but images from SPECT/CT scanners are not quantitative and require calibration using nuclear medicine phantoms. While phantom studies can validate a scanner's ability to recover activity concentrations, these studies provide only a surrogate for the true metric of interest: absorbed doses. Measurements using thermoluminescent dosimeters (TLDs) are a versatile and accurate method of measuring absorbed dose. In this work, a TLD probe was manufactured that can fit into currently available nuclear medicine phantoms for the measurement of absorbed dose of RPT agents. Next, 748 MBq of I-131 was administered to a 16 ml hollow source sphere placed in a 6.4 L Jaszczak phantom in addition to six TLD probes, each holding 4 TLD-100 1 × 1 × 1 mm TLD-100 (LiF:Mg,Ti) microcubes. The phantom then underwent a SPECT/CT scan in accordance with a standard SPECT/CT imaging protocol for I-131. The SPECT/CT images were then input into a Monte Carlo based RPT dosimetry platform named RAPID and a three dimensional dose distribution in the phantom was estimated. Additionally, a GEANT4 benchmarking scenario (denoted 'idealized') was created using a stylized representation of the phantom. There was good agreement for all six probes, the differences between measurement and RAPID ranged between -5.5% and 0.9%. The difference between the measured and the idealized GEANT4 scenario was calculated and ranged from -4.3% and -20.5%. This work demonstrates good agreement between TLD measurements and RAPID. In addition, it introduces a novel TLD probe that can be easily introduced into clinical nuclear medicine workflows to provide QA of image-based dosimetry for RPT treatments.
Collapse
Affiliation(s)
- David P Adam
- Department of Medical Physics, University of Wisconsin-Madison, Madison, WI, 53705, United States of America
| | - Clifford Hammer
- Department of Medical Physics, University of Wisconsin-Madison, Madison, WI, 53705, United States of America
| | - Julia Ziege Malyshev
- Department of Medical Physics, University of Wisconsin-Madison, Madison, WI, 53705, United States of America
| | - Wesley S Culberson
- Department of Medical Physics, University of Wisconsin-Madison, Madison, WI, 53705, United States of America
| | - Tyler J Bradshaw
- Department of Radiology, University of Wisconsin-Madison, Madison, WI, 53705, United States of America
| | - Joseph J Grudzinski
- Department of Radiology, University of Wisconsin-Madison, Madison, WI, 53705, United States of America
| | - Paul M Harari
- Department of Human Oncology, University of Wisconsin-Madison, Madison, WI, 53705, United States of America
| | - Bryan P Bednarz
- Department of Medical Physics, University of Wisconsin-Madison, Madison, WI, 53705, United States of America
| |
Collapse
|
15
|
Salerno KE, Roy S, Ribaudo C, Fisher T, Patel RB, Mena E, Escorcia FE. A Primer on Radiopharmaceutical Therapy. Int J Radiat Oncol Biol Phys 2023; 115:48-59. [PMID: 35970373 PMCID: PMC9772089 DOI: 10.1016/j.ijrobp.2022.08.010] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2022] [Revised: 07/25/2022] [Accepted: 08/03/2022] [Indexed: 12/24/2022]
Abstract
The goal of this article is to serve as a primer for the United States-based radiation oncologist who may be interested in learning more about radiopharmaceutical therapy (RPT). Specifically, we define RPT, review the data behind its current and anticipated indications, and discuss important regulatory considerations for incorporating it into clinical practice. RPT represents an opportunity for radiation oncologists to leverage 2 key areas of expertise, namely therapeutic radiation therapy and oncology, and apply them in a distinct context in collaboration with nuclear medicine and medical oncology colleagues. Although not every radiation oncologist will incorporate RPT into their day-to-day practice, it is important to understand the role for this modality and how it can be appropriately used in select patients.
Collapse
Affiliation(s)
- Kilian E Salerno
- Radiation Oncology Branch, National Cancer Institute, National Institutes of Health, Bethesda, Maryland
| | - Soumyajit Roy
- Radiation Oncology Department, Rush Medical Center, Chicago, Illinois
| | - Cathy Ribaudo
- Division of Radiation Safety, National Institutes of Health, Bethesda, Maryland
| | - Teresa Fisher
- Division of Radiation Safety, National Institutes of Health, Bethesda, Maryland
| | - Ravi B Patel
- Radiation Oncology Department, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania
| | - Esther Mena
- Molecular Imaging Branch, National Cancer Institute, National Institutes of Health, Bethesda, Maryland
| | - Freddy E Escorcia
- Radiation Oncology Branch, National Cancer Institute, National Institutes of Health, Bethesda, Maryland; Molecular Imaging Branch, National Cancer Institute, National Institutes of Health, Bethesda, Maryland.
| |
Collapse
|
16
|
Kerr CP, Grudzinski JJ, Nguyen TP, Hernandez R, Weichert JP, Morris ZS. Developments in Combining Targeted Radionuclide Therapies and Immunotherapies for Cancer Treatment. Pharmaceutics 2022; 15:128. [PMID: 36678756 PMCID: PMC9865370 DOI: 10.3390/pharmaceutics15010128] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2022] [Revised: 12/26/2022] [Accepted: 12/27/2022] [Indexed: 01/01/2023] Open
Abstract
Targeted radionuclide therapy (TRT) and immunotherapy are rapidly growing classes of cancer treatments. Basic, translational, and clinical research are now investigating therapeutic combinations of these agents. In comparison to external beam radiation therapy (EBRT), TRT has the unique advantage of treating all disease sites following intravenous injection and selective tumor uptake and retention-a particularly beneficial property in metastatic disease settings. The therapeutic value of combining radiation therapy with immune checkpoint blockade to treat metastases has been demonstrated in preclinical studies, whereas results of clinical studies have been mixed. Several clinical trials combining TRT and immune checkpoint blockade have been initiated based on preclinical studies combining these with EBRT and/or TRT. Despite the interest in translation of TRT and immunotherapy combinations, many questions remain surrounding the mechanisms of interaction and the optimal approach to clinical implementation of these combinations. This review highlights the mechanisms of interaction between anti-tumor immunity and radiation therapy and the status of basic and translational research and clinical trials investigating combinations of TRT and immunotherapies.
Collapse
Affiliation(s)
- Caroline P. Kerr
- Department of Radiology, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, WI 53705, USA
- Department of Human Oncology, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, WI 53705, USA
| | - Joseph J. Grudzinski
- Department of Radiology, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, WI 53705, USA
| | - Thanh Phuong Nguyen
- Department of Human Oncology, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, WI 53705, USA
| | - Reinier Hernandez
- Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, WI 53705, USA
| | - Jamey P. Weichert
- Department of Radiology, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, WI 53705, USA
| | - Zachary S. Morris
- Department of Human Oncology, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, WI 53705, USA
| |
Collapse
|
17
|
Sun J, Huangfu Z, Yang J, Wang G, Hu K, Gao M, Zhong Z. Imaging-guided targeted radionuclide tumor therapy: From concept to clinical translation. Adv Drug Deliv Rev 2022; 190:114538. [PMID: 36162696 DOI: 10.1016/j.addr.2022.114538] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2022] [Revised: 09/03/2022] [Accepted: 09/11/2022] [Indexed: 01/24/2023]
Abstract
Since the first introduction of sodium iodide I-131 for use with thyroid patients almost 80 years ago, more than 50 radiopharmaceuticals have reached the markets for a wide range of diseases, especially cancers. The nuclear medicine paradigm also shifts from solely molecular imaging or radionuclide therapy to imaging-guided radionuclide therapy, which is deemed a vital component of precision cancer therapy and an emerging medical modality for personalized medicine. The imaging-guided radionuclide therapy highlights the systematic integration of targeted nuclear diagnostics and radionuclide therapeutics. Regarding this, nuclear imaging serves to "visualize" the lesions and guide the therapeutic strategy, followed by administration of a precise patient specific dose of radiotherapeutics for treatment according to the absorbed dose to different organs and tumors calculated by dosimetry tools, and finally repeated imaging to predict the prognosis. This strategy leads to significantly enhanced therapeutic efficacy, improved patient outcomes, and manageable adverse events. In this review, we provide an overview of imaging-guided targeted radionuclide therapy for different tumors such as advanced prostate cancer and neuroendocrine tumors, with a focus on development of new radioligands and their preclinical and clinical results, and further discuss about challenges and future perspectives.
Collapse
Affiliation(s)
- Juan Sun
- College of Pharmaceutical Sciences, and State Key Laboratory of Radiation Medicine and Protection, Soochow University, Suzhou 215123, People's Republic of China; Biomedical Polymers Laboratory, College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Suzhou 215123, People's Republic of China
| | - Zhenyuan Huangfu
- College of Pharmaceutical Sciences, and State Key Laboratory of Radiation Medicine and Protection, Soochow University, Suzhou 215123, People's Republic of China; Biomedical Polymers Laboratory, College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Suzhou 215123, People's Republic of China
| | - Jiangtao Yang
- College of Pharmaceutical Sciences, and State Key Laboratory of Radiation Medicine and Protection, Soochow University, Suzhou 215123, People's Republic of China; Biomedical Polymers Laboratory, College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Suzhou 215123, People's Republic of China
| | - Guanglin Wang
- State Key Laboratory of Radiation Medicine and Protection, School of Radiation Medicine and Protection & School for Radiological and Interdisciplinary Sciences (RAD-X), Collaborative Innovation Center of Radiation Medicine of Jiangsu Higher Education Institutions, Soochow University, Suzhou 215123, People's Republic of China.
| | - Kuan Hu
- Department of Advanced Nuclear Medicine Sciences, Institute for Quantum Medical Sciences, Quantum Life and Medical Science Directorate, National Institutes for Quantum Science and Technology, Chiba 263-8555, Japan.
| | - Mingyuan Gao
- State Key Laboratory of Radiation Medicine and Protection, School of Radiation Medicine and Protection & School for Radiological and Interdisciplinary Sciences (RAD-X), Collaborative Innovation Center of Radiation Medicine of Jiangsu Higher Education Institutions, Soochow University, Suzhou 215123, People's Republic of China
| | - Zhiyuan Zhong
- College of Pharmaceutical Sciences, and State Key Laboratory of Radiation Medicine and Protection, Soochow University, Suzhou 215123, People's Republic of China; Biomedical Polymers Laboratory, College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Suzhou 215123, People's Republic of China.
| |
Collapse
|
18
|
O'Donoghue J, Zanzonico P, Humm J, Kesner A. Dosimetry in Radiopharmaceutical Therapy. J Nucl Med 2022; 63:1467-1474. [PMID: 36192334 DOI: 10.2967/jnumed.121.262305] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2021] [Accepted: 07/14/2022] [Indexed: 11/27/2022] Open
Abstract
The application of radiopharmaceutical therapy for the treatment of certain diseases is well established, and the field is expanding. New therapeutic radiopharmaceuticals have been developed in recent years, and more are in the research pipeline. Concurrently, there is growing interest in the use of internal dosimetry as a means of personalizing, and potentially optimizing, such therapy for patients. Internal dosimetry is multifaceted, and the current state of the art is discussed in this continuing education article. Topics include the context of dosimetry, internal dosimetry methods, the advantages and disadvantages of incorporating dosimetry calculations in radiopharmaceutical therapy, a description of the workflow for implementing patient-specific dosimetry, and future prospects in the field.
Collapse
Affiliation(s)
- Joe O'Donoghue
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York
| | - Pat Zanzonico
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York
| | - John Humm
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York
| | - Adam Kesner
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York
| |
Collapse
|
19
|
Piwowarska-Bilska H, Kurkowska S, Birkenfeld B. Individualization of Radionuclide Therapies: Challenges and Prospects. Cancers (Basel) 2022; 14:cancers14143418. [PMID: 35884478 PMCID: PMC9316481 DOI: 10.3390/cancers14143418] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2022] [Revised: 07/04/2022] [Accepted: 07/12/2022] [Indexed: 02/01/2023] Open
Abstract
Simple Summary Currently, patient-specific treatment plans and dosimetry calculations are not routinely performed for radionuclide therapies. In external beam radiotherapy, it is quite the opposite. As a result, a small fraction of patients receives optimal radioactivity. This conservative approach provides “radiation safety” to healthy tissues but delivers a lower than indicated absorbed dose to the tumors, resulting in a lower response rate and a higher disease relapse rate. Evidence shows that better and more predictable outcomes can be achieved with patient-individualized dose assessment. Therefore, the incorporation of individual planning into radionuclide therapies is a high priority for nuclear medicine physicians and medical physicists alike. Internal dosimetry is used in tumor therapy to optimize the absorbed dose to the target tissue. The main reasons for the difficulties in incorporating patients’ internal dosimetry into routine clinical practice are discussed. The article presents the prospects for the routine implementation of personalized radionuclide therapies. Abstract The article presents the problems of clinical implementation of personalized radioisotope therapy. The use of radioactive drugs in the treatment of malignant and benign diseases is rapidly expanding. Currently, in the majority of nuclear medicine departments worldwide, patients receive standard activities of therapeutic radiopharmaceuticals. Intensively conducted clinical trials constantly provide more evidence of a close relationship between the dose of radiopharmaceutical absorbed in pathological tissues and the therapeutic effect of radioisotope therapy. Due to the lack of individual internal dosimetry (based on the quantitative analysis of a series of diagnostic images) before or during the treatment, only a small fraction of patients receives optimal radioactivity. The vast majority of patients receive too-low doses of ionizing radiation to the target tissues. This conservative approach provides “radiation safety” to healthy tissues, but also delivers lower radiopharmaceutical activity to the neoplastic tissue, resulting in a low level of response and a higher relapse rate. The article presents information on the currently used radionuclides in individual radioisotope therapies and on radionuclides newly introduced to the therapeutic market. It discusses the causes of difficulties with the implementation of individualized radioisotope therapies as well as possible changes in the current clinical situation.
Collapse
|
20
|
Soulek DK, Mastascusa NJ, Martin ME, Graves SA. Practical Considerations for Implementation of 177Lu-DOTATATE Neuroendocrine Tumor Treatment Programs. J Nucl Med Technol 2022; 50:jnmt.122.263813. [PMID: 35701215 DOI: 10.2967/jnmt.122.263813] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2022] [Accepted: 06/08/2022] [Indexed: 11/16/2022] Open
Abstract
The 2018 FDA approval of 177Lu-DOTATATE for the treatment of somatostatin receptor-positive (SSTR) neuroendocrine tumors (NETs) represents a paradigm shifting approach to cancer treatments around the globe. Gastroenteropancreatic (GEP) NETs overexpress the somatostatin subtype receptor 2, which is now exploited for receptor-based imaging and therapy, thus generating significant progress in the diagnosis and treatment of this orphan disease. The recent FDA approval of receptor-based PET radiopharmaceuticals and a new peptide receptor radiopharmaceutical therapy (PRRT), 177Lu-DOTATATE, has dramatically impacted NET patient management. The focus of this paper is to review clinical considerations associated with implementing a 177Lu-DOTATATE program. We review receptor-based NET radiopharmaceuticals, 177Lu-DOTATATE patient selection criteria, administration methods, clinical, regulatory, and radiation safety considerations, technical factors, tissue dosimetry, and reimbursement guidelines.
Collapse
|
21
|
Park EA, Graves SA, Menda Y. The Impact of Radiopharmaceutical Therapy on Renal Function. Semin Nucl Med 2022; 52:467-474. [DOI: 10.1053/j.semnuclmed.2022.02.004] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2022] [Revised: 02/13/2022] [Accepted: 02/20/2022] [Indexed: 11/11/2022]
|
22
|
Pettinato C, Richetta E, Cremonesi M. Dosimetry with single photon emission tomography (SPECT). Nucl Med Mol Imaging 2022. [DOI: 10.1016/b978-0-12-822960-6.00173-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
|
23
|
Wahl RL, Sgouros G, Iravani A, Jacene H, Pryma D, Saboury B, Capala J, Graves SA. Normal-Tissue Tolerance to Radiopharmaceutical Therapies, the Knowns and the Unknowns. J Nucl Med 2021; 62:23S-35S. [PMID: 34857619 DOI: 10.2967/jnumed.121.262751] [Citation(s) in RCA: 40] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2021] [Revised: 10/15/2021] [Indexed: 12/25/2022] Open
Affiliation(s)
- Richard L Wahl
- Mallinckrodt Institute of Radiology, Washington University, St. Louis, Missouri
| | - George Sgouros
- Department of Radiology, Johns Hopkins University, Baltimore, Maryland
| | - Amir Iravani
- Mallinckrodt Institute of Radiology, Washington University, St. Louis, Missouri
| | | | - Daniel Pryma
- Penn Medicine, University of Pennsylvania, Philadelphia, Pennsylvania
| | | | - Jacek Capala
- National Institutes of Health, Bethesda, Maryland
| | | |
Collapse
|