1
|
Hollestelle MJ, Kristoffersen AH, Idema RN, Meijer P, Sandberg S, de Maat MPM, Aarsand AK. Systematic review and meta-analysis of within-subject and between-subject biological variation data of coagulation and fibrinolytic measurands. Clin Chem Lab Med 2023; 61:1470-1480. [PMID: 36810291 DOI: 10.1515/cclm-2022-1207] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2022] [Accepted: 02/10/2023] [Indexed: 02/24/2023]
Abstract
OBJECTIVES The diagnosis and monitoring of bleeding and thrombotic disorders depend on correct haemostatic measurements. The availability of high-quality biological variation (BV) data is important in this context. Many studies have reported BV data for these measurands, but results are varied. The present study aims to deliver global within-subject (CVI) and between-subject (CVG) BV estimates for haemostasis measurands by meta-analyses of eligible studies, by assessment with the Biological Variation Data Critical Appraisal Checklist (BIVAC). METHODS Relevant BV studies were graded by the BIVAC. Weighted estimates for CVI and CVG were obtained via meta-analysis of the BV data derived from BIVAC-compliant studies (graded A-C; whereby A represents optimal study design) performed in healthy adults. RESULTS In 26 studies BV data were reported for 35 haemostasis measurands. For 9 measurands, only one eligible publication was identified and meta-analysis could not be performed. 74% of the publications were graded as BIVAC C. The CVI and CVG varied extensively between the haemostasis measurands. The highest estimates were observed for PAI-1 antigen (CVI 48.6%; CVG 59.8%) and activity (CVI 34.9%; CVG 90.2%), while the lowest were observed for activated protein C resistance ratio (CVI 1.5%; CVG 4.5%). CONCLUSIONS This study provides updated BV estimates of CVI and CVG with 95% confidence intervals for a wide range of haemostasis measurands. These estimates can be used to form the basis for analytical performance specifications for haemostasis tests used in the diagnostic work-up required in bleeding- and thrombosis events and for risk assessment.
Collapse
Affiliation(s)
- Martine J Hollestelle
- ECAT Foundation (External Quality Control for Assays and Tests), Voorschoten, The Netherlands
| | - Ann Helen Kristoffersen
- Department of Medical Biochemistry and Pharmacology, Haukeland University Hospital, Bergen, Norway
- Norwegian Organization for Quality Improvement of Laboratory Examinations (Noklus), Haraldsplass Deaconess Hospital, Bergen, Norway
| | - René N Idema
- Result Laboratory, Amphia Hospital, Breda, The Netherlands
| | - Piet Meijer
- ECAT Foundation (External Quality Control for Assays and Tests), Voorschoten, The Netherlands
| | - Sverre Sandberg
- Department of Medical Biochemistry and Pharmacology, Haukeland University Hospital, Bergen, Norway
- Norwegian Organization for Quality Improvement of Laboratory Examinations (Noklus), Haraldsplass Deaconess Hospital, Bergen, Norway
- European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) Working Group on Biological Variation and Task Group for the Biological Variation Database, Milan, Italy
| | - Moniek P M de Maat
- Department of Hematology, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands
| | - Aasne K Aarsand
- Department of Medical Biochemistry and Pharmacology, Haukeland University Hospital, Bergen, Norway
- Norwegian Organization for Quality Improvement of Laboratory Examinations (Noklus), Haraldsplass Deaconess Hospital, Bergen, Norway
- European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) Working Group on Biological Variation and Task Group for the Biological Variation Database, Milan, Italy
| |
Collapse
|
2
|
Wool GD. Benefits and Pitfalls of Point-of-Care Coagulation Testing for Anticoagulation Management: An ACLPS Critical Review. Am J Clin Pathol 2019; 151:1-17. [PMID: 30215666 DOI: 10.1093/ajcp/aqy087] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023] Open
Abstract
Objectives Point-of-care (POC) testing is generally less precise and has higher reagent costs per test than laboratory-based assays. However, POC hemostasis testing can offer significant advantages in particular situations: patient-managed warfarin therapy as well as rapid turnaround time heparin management for intraoperative patients. Of note, POC hemostasis testing is generally approved for the purposes of anticoagulation monitoring and is inferior to laboratory coagulation testing for the diagnosis of congenital or acquired coagulopathy. Methods The frequently used POC coagulation instruments for POC international normalized ratio and activated clotting time are reviewed, as well as their typical performance relative to central laboratory testing (where available). Results Several cases are discussed that highlight the benefits, as well as pitfalls, of POC coagulation testing. Conclusions POC coagulation testing for anticoagulation monitoring offers advantages in particular situations. Clear policies and protocols must be developed to guide proper use of POC versus central laboratory hemostasis testing.
Collapse
Affiliation(s)
- Geoffrey D Wool
- The Department of Pathology, University of Chicago, Chicago, IL
| |
Collapse
|
3
|
Biedermann JS, van den Besselaar AMHP, de Maat MPM, Leebeek FWG, Kruip MJHA. Monitoring of treatment with vitamin K antagonists: recombinant thromboplastins are more sensitive to factor VII than tissue-extract thromboplastins. J Thromb Haemost 2017; 15:500-506. [PMID: 28055147 DOI: 10.1111/jth.13611] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2016] [Indexed: 11/29/2022]
Abstract
Essentials Differences in sensitivity to factor VII (FVII) have been suggested between thromboplastins. FVII-induced International Normalized Ratio (INR) changes differ between commercial reagents. Recombinant human thromboplastins are more sensitive to FVII than tissue-extract thromboplastins. Thromboplastin choice may affect FVII-mediated INR stability. SUMMARY Background Differences regarding sensitivity to factor VII have been suggested for recombinant human and tissue-extract thromboplastins used for International Normalized Ratio (INR) measurement, but the evidence is scarce. Differences in FVII sensitivity are clinically relevant, as they can affect INR stability during treatment with vitamin K antagonists (VKAs). Objectives To determine whether commercial thromboplastins react differently to changes in FVII. Methods We studied the effect of addition of FVII on the INR in plasma by using three tissue-extract (Neoplastin C1+, Hepato Quick, and Thromborel S) and three recombinant human (Recombiplastin 2G, Innovin, and CoaguChek XS) thromboplastins. Three different concentrations of purified human FVII (0.006, 0.012 and 0.062 μg mL-1 plasma), or buffer, were added to five certified pooled plasmas of patients using VKAs (INR of 1.5-3.5). Changes in FVII activity were measured with two bioassays (Neoplastin and Recombiplastin), and relative INR changes were compared between reagents. Results After addition of 0.062 μg mL-1 FVII, FVII activity in the pooled plasmas increased by approximately 20% (Neoplastin) or 32% (Recombiplastin) relative to the activity in pooled normal plasma. All thromboplastins showed dose-dependent INR decreases. The relative INR change in the pooled plasmas significantly differed between the six thromboplastins. No differences were observed among recombinant or tissue-extract thromboplastins. Pooled results indicated that the FVII-induced INR change was greater for recombinant than for tissue-extract thromboplastins. Conclusions Differences regarding FVII sensitivity exist between various thromboplastins used for VKA monitoring. Recombinant human thromboplastins are more sensitive to FVII than tissue-extract thromboplastins. Therefore, thromboplastin choice may affect FVII-mediated INR stability.
Collapse
Affiliation(s)
- J S Biedermann
- Department of Hematology, Erasmus University Medical Center, Rotterdam, the Netherlands
- Star-Medical Diagnostic Center, Rotterdam, the Netherlands
| | | | - M P M de Maat
- Department of Hematology, Erasmus University Medical Center, Rotterdam, the Netherlands
| | - F W G Leebeek
- Department of Hematology, Erasmus University Medical Center, Rotterdam, the Netherlands
| | - M J H A Kruip
- Department of Hematology, Erasmus University Medical Center, Rotterdam, the Netherlands
- Star-Medical Diagnostic Center, Rotterdam, the Netherlands
| |
Collapse
|
4
|
Biedermann JS, van den Besselaar AM, Leebeek FW, Kruip MJ. Impact of point-of-care international normalized ratio monitoring on quality of treatment with vitamin K antagonists in non-self-monitoring patients: a cohort study: reply. J Thromb Haemost 2016; 14:2312-2314. [PMID: 27565455 DOI: 10.1111/jth.13485] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- J S Biedermann
- Department of Hematology, Erasmus University Medical Center, Rotterdam, the Netherlands
- Star-Medical Diagnostic Center, Rotterdam, the Netherlands
| | - A M van den Besselaar
- Department of Thrombosis and Hemostasis, Leiden University Medical Center, Leiden, the Netherlands
| | - F W Leebeek
- Department of Hematology, Erasmus University Medical Center, Rotterdam, the Netherlands
| | - M J Kruip
- Department of Hematology, Erasmus University Medical Center, Rotterdam, the Netherlands
- Star-Medical Diagnostic Center, Rotterdam, the Netherlands
| |
Collapse
|
5
|
Biedermann JS, van Rein N, van den Besselaar AMHP, Buhre PN, de Maat MPM, van der Meer FJM, Leebeek FWG, Kruip MJHA. Impact of point-of-care international normalized ratio monitoring on quality of treatment with vitamin K antagonists in non-self-monitoring patients: a cohort study. J Thromb Haemost 2016; 14:695-703. [PMID: 26806724 DOI: 10.1111/jth.13272] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2015] [Accepted: 01/07/2016] [Indexed: 11/27/2022]
Abstract
BACKGROUND Point-of-care (POC) international normalized ratio (INR) monitoring by healthcare professionals could eliminate the need for venous blood sampling in non-self-monitoring (NSM) patients on vitamin K antagonists (VKA). However, few studies have investigated the impact of POC INR monitoring on the quality of treatment in these patients and real-world data on this issue are lacking. OBJECTIVES To investigate the safety, efficacy and quality of anticoagulant control during POC INR monitoring as compared with laboratory INR monitoring in NSM patients. METHODS We performed a retrospective cohort study using data from the anticoagulation clinic of the Star-Medical Diagnostic Center (Rotterdam, the Netherlands). Patients who received treatment with VKA between 29 May 2012 and 29 May 2014 were eligible. Percentage of time in therapeutic range (TTR) and incidence rates of major clinical events (all-cause mortality, hospitalization, major bleeding and ischemic stroke) were compared for the year before and year after introduction of POC monitoring. Cox proportional hazard models were used to estimate hazard ratios and 95% confidence intervals for major clinical events between exposure groups. RESULTS In total, 1973 patients during the 1-year laboratory-monitoring observation period and 1959 patients during the 1-year POC-monitoring observation period were included. Median TTR was significantly lower during POC monitoring (77.9%; 95% CI, 67.2-87.4) than during laboratory INR monitoring (81.0%; 95% CI, 71.1-90.5). Adjusted hazard ratios for major clinical events were all around unity. CONCLUSIONS Although associated with lower TTR, POC INR monitoring is a safe and effective alternative to laboratory INR monitoring in NSM patients on VKA.
Collapse
Affiliation(s)
- J S Biedermann
- Department of Hematology, Erasmus University Medical Center, Rotterdam, the Netherlands
- Star-Medical Diagnostic Center, Rotterdam, the Netherlands
| | - N van Rein
- Department of Thrombosis and Hemostasis, Leiden University Medical Center, Leiden, the Netherlands
- Einthoven Laboratory for Experimental Vascular Medicine, Leiden University Medical Center, Leiden, the Netherlands
| | | | - P N Buhre
- Star-Medical Diagnostic Center, Rotterdam, the Netherlands
| | - M P M de Maat
- Department of Hematology, Erasmus University Medical Center, Rotterdam, the Netherlands
| | - F J M van der Meer
- Department of Thrombosis and Hemostasis, Leiden University Medical Center, Leiden, the Netherlands
| | - F W G Leebeek
- Department of Hematology, Erasmus University Medical Center, Rotterdam, the Netherlands
| | - M J H A Kruip
- Department of Hematology, Erasmus University Medical Center, Rotterdam, the Netherlands
- Star-Medical Diagnostic Center, Rotterdam, the Netherlands
| |
Collapse
|
6
|
Yan X, Yang F, Zhou H, Zhang H, Liu J, Ma K, Li Y, Zhu J, Ding J. Effects of VKORC1 Genetic Polymorphisms on Warfarin Maintenance Dose Requirement in a Chinese Han Population. Med Sci Monit 2015; 21:3577-84. [PMID: 26583785 PMCID: PMC4657763 DOI: 10.12659/msm.894414] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
Background VKORC1 is reported to be capable of treating several diseases with thrombotic risk, such as cardiac valve replacement. Some single-nucleotide polymorphisms (SNPs) in VKORC1 are documented to be associated with clinical differences in warfarin maintenance dose. This study explored the correlations of VKORC1–1639 G/A, 1173 C/T and 497 T/G genetic polymorphisms with warfarin maintenance dose requirement in patients undergoing cardiac valve replacement. Material/Methods A total of 298 patients undergoing cardiac valve replacement were recruited. During follow-up, clinical data were recorded. Polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP) method was applied to detect VKORC1–1639 G/A, 1173 C/T and 497 T/G polymorphisms, and genotypes were analyzed. Results Correlations between warfarin maintenance dose and baseline characteristics revealed statistical significances of age, gender and operation methods with warfarin maintenance dose (all P<0.05). Warfarin maintenance dose in VKORC1–1639 G/A AG + GG carriers was obviously higher than in AA carriers (P<0.001). As compared with patients with TT genotype in VKORC1 1173 C/T, warfarin maintenance dose was apparently higher in patients with CT genotype (P<0.001). Linear regression analysis revealed that gender, operation method, method for heart valve replacement, as well as VKORC1–1639 G/A and 1173 C/T gene polymorphisms were significantly related to warfarin maintenance dose (all P<0.05). Conclusions VKORC1 gene polymorphisms are key genetic factors to affect individual differences in warfarin maintenance dose in patients undergoing cardiac valve replacement; meanwhile, gender, operation method and method for heart valve replacement might also be correlate with warfarin maintenance dose.
Collapse
Affiliation(s)
- Xiaojuan Yan
- Department of Respiratory Medicine, Xiangyang Central Hospital, Affiliated Hospital of Hubei College of Arts and Science, Xiangyang, Hubei, China (mainland)
| | - Feng Yang
- Department of Cardiovascular Medicine, Xiangyang Central Hospital, Affiliated Hospital of Hubei College of Arts and Science, Xiangyang, Hubei, China (mainland)
| | - Hanyun Zhou
- Department of Cardiovascular Medicine, Xiangyang Central Hospital, Affiliated Hospital of Hubei College of Arts and Science, Xiangyang, Hubei, China (mainland)
| | - Hongshen Zhang
- Department of Cardiovascular Medicine, Xiangyang Central Hospital, Affiliated Hospital of Hubei College of Arts and Science, Xiangyang, Hubei, China (mainland)
| | - Jianfei Liu
- Department of Cardiovascular Medicine, Xiangyang Central Hospital, Affiliated Hospital of Hubei College of Arts and Science, Xiangyang, Hubei, China (mainland)
| | - Kezhong Ma
- Department of Cardiovascular Medicine, Xiangyang Central Hospital, Affiliated Hospital of Hubei College of Arts and Science, Xiangyang, Hubei, China (mainland)
| | - Yi Li
- Department of Pharmacy, Ministry of Health Beijing Hospital, Beijing, China (mainland)
| | - Jun Zhu
- Medical Department, Henan Provincial Corps Hospital of Chinese People's Armed Police Force, Zhengzhou, Henan, China (mainland)
| | - Jianqiang Ding
- Medical Department, Henan Provincial Corps Hospital of Chinese People's Armed Police Force, Zhengzhou, Henan, China (mainland)
| |
Collapse
|
7
|
Li Y, Zhu J, Ding J. VKORC1 -1639G/A and 1173 C/T Genetic Polymorphisms Influence Individual Differences in Warfarin Maintenance Dose. Genet Test Mol Biomarkers 2015; 19:488-93. [PMID: 26167638 DOI: 10.1089/gtmb.2015.0097] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023] Open
Abstract
OBJECTIVE In this study, we investigated two VKORC1 gene polymorphisms, -1639G/A and 1173C/T, for effects on warfarin maintenance dosage in valvular heart disease (VHD) patients after cardiac valve replacement (CVR). METHODS A total of 219 VHD patients receiving warfarin therapy after CVR surgery were recruited to this study between June 2010 and December 2013. Basic clinical data, prothrombin time, warfarin maintenance dose, and blood samples were collected from all patients. Polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP) analyses were used to analyze the VKORC1 -1639G/A and 1173C/T polymorphisms. SPSS version 19.0 software was used for statistical analysis of the data. RESULTS Patients with either the AG+or GG genotype (n=32) of the VKORC1 -1639G/A polymorphism required a significantly higher warfarin dose compared to patients with the AA genotype (n=187) (4.36±1.03 mg/day vs. 2.95±0.94 mg/day; p<0.001). Similarly, patients carrying the CT genotype (n=28) of the VKORC1 1173C/T polymorphism also required a significantly higher warfarin dose compared to those with the TT genotype (n=191) (4.19±0.99 mg/day vs. 3.00±0.94 mg/day; p<0.001). Linear regression analysis showed that gender, age, weight, and VKORC1 -1639G/A and 1173C/T polymorphisms were correlated with individual differences in warfarin maintenance dose (all p<0.05). CONCLUSION We present evidence that the two VKORC1 polymorphisms, -1639G/A and 1173C/T, are key genetic factors influencing individual differences in warfarin maintenance dose in VHD patients who underwent CVR. Gender, age, and weight also independently correlated with warfarin maintenance dose.
Collapse
Affiliation(s)
- Yi Li
- 1 Department of Pharmacy, Ministry of Health Beijing Hospital , Beijing, People's Republic of China
| | - Jun Zhu
- 2 Medical Department, Henan Provincial Corps Hospital of Chinese People's Armed Police Force , Zhengzhou, People's Republic of China
| | - Jianqiang Ding
- 2 Medical Department, Henan Provincial Corps Hospital of Chinese People's Armed Police Force , Zhengzhou, People's Republic of China
| |
Collapse
|