Langaa SS, Lauridsen TG, Mose FH, Fynbo CA, Theil J, Bech JN. Estimation of renal perfusion based on measurement of rubidium-82 clearance by PET/CT scanning in healthy subjects.
EJNMMI Phys 2021;
8:43. [PMID:
34057645 PMCID:
PMC8167076 DOI:
10.1186/s40658-021-00389-0]
[Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2020] [Accepted: 05/12/2021] [Indexed: 11/18/2022] Open
Abstract
Background
Changes in renal blood flow (RBF) may play a pathophysiological role in hypertension and kidney disease. However, RBF determination in humans has proven difficult. We aimed to confirm the feasibility of RBF estimation based on positron emission tomography/computed tomography (PET/CT) and rubidium-82 (82Rb) using the abdominal aorta as input function in a 1-tissue compartment model.
Methods
Eighteen healthy subjects underwent two dynamic 82Rb PET/CT scans in two different fields of view (FOV). FOV-A included the left ventricular blood pool (LVBP), the abdominal aorta (AA) and the majority of the kidneys. FOV-B included AA and the kidneys in their entirety. In FOV-A, an input function was derived from LVBP and from AA, in FOV-B from AA. One-tissue compartmental modelling was performed using tissue time activity curves generated from volumes of interest (VOI) contouring the kidneys, where the renal clearance of 82Rb is represented by the K1 kinetic parameter. Total clearance for both kidneys was calculated by multiplying the K1 values with the volume of VOIs used for analysis. Intra-assay coefficients of variation and inter-observer variation were calculated.
Results
For both kidneys, K1 values derived from AA did not differ significantly from values obtained from LVBP, neither were significant differences seen between AA in FOV-A and AA in FOV-B, nor between the right and left kidneys. For both kidneys, the intra-assay coefficients of variation were low (~ 5%) for both input functions. The measured K1 of 2.80 ml/min/cm3 translates to a total clearance for both kidneys of 766 ml/min/1.73 m2.
Conclusion
Measurement of renal perfusion based on PET/CT and 82Rb using AA as input function in a 1-tissue compartment model is feasible in a single FOV. Based on previous studies showing 82Rb to be primarily present in plasma, the measured K1 clearance values are most likely representative of effective renal plasma flow (ERPF) rather than estimated RBF values, but as the accurate calculation of total clearance/flow is very much dependent on the analysed volume, a standardised definition for the employed renal volumes is needed to allow for proper comparison with standard ERPF and RBF reference methods.