Lari S, Kohandel M, Kwon HJ. Model based deep learning method for focused ultrasound pathway scanning. Sci Rep 2024; 14:20042. [PMID: 39198623 PMCID: PMC11358149 DOI: 10.1038/s41598-024-70689-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2024] [Accepted: 08/20/2024] [Indexed: 09/01/2024] Open
Abstract
The primary purpose of high-intensity focused ultrasound (HIFU), a non-invasive medical therapy, is to precisely target and ablate tumors by focusing high-frequency ultrasound from an external power source. A series of ablations must be performed in order to treat a big volume of tumors, as a single ablation can only remove a small amount of tissue. To maximize therapeutic efficacy while minimizing adverse side effects such as skin burns, preoperative treatment planning is essential in determining the focal site and sonication duration for each ablation. Here, we introduce a machine learning-based approach for designing HIFU treatment plans, which makes use of a map of the material characteristics unique to a patient alongside an accurate thermal simulation. A numerical model was employed to solve the governing equations of HIFU process and to simulate the HIFU absorption mechanism, including ensuing heat transfer process and the temperature rise during the sonication period. To validate the accuracy of this numerical model, a series of tests was conducted using ex vivo bovine liver. The findings indicate that the developed models properly represent the considerable variances observed in tumor geometrical shapes and proficiently generate well-defined closed treated regions based on imaging data. The proposed strategy facilitated the formulation of high-quality treatment plans, with an average tissue over- or under-treatment rate of less than 0.06%. The efficacy of the numerical model in accurately predicting the heating process of HIFU, when combined with machine learning techniques, was validated through quantitative comparison with experimental data. The proposed approach in cooperation with HIFU simulation holds the potential to enhance presurgical HIFU plan.
Collapse
Affiliation(s)
- Salman Lari
- Department of Mechanical and Mechatronics Engineering, University of Waterloo, Waterloo, ON, N2L 3G1, Canada
| | - Mohammad Kohandel
- Department of Applied Mathematics, University of Waterloo, Waterloo, ON, N2L 3G1, Canada
| | - Hyock Ju Kwon
- Department of Mechanical and Mechatronics Engineering, University of Waterloo, Waterloo, ON, N2L 3G1, Canada.
| |
Collapse
|
2
|
MR Imaging in Real Time Guiding of Therapies in Prostate Cancer. Life (Basel) 2022; 12:life12020302. [PMID: 35207589 PMCID: PMC8878909 DOI: 10.3390/life12020302] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2022] [Revised: 01/31/2022] [Accepted: 02/11/2022] [Indexed: 11/22/2022] Open
Abstract
Magnetic resonance imaging (MRI)-guided therapy for prostate cancer (PCa) aims to reduce the treatment-associated comorbidity of existing radical treatment, including radical prostatectomy and radiotherapy. Although active surveillance has been used as a conservative method to reduce overtreatment, there is a growing demand for less morbidity and personalized (focal) treatment. The development of multiparametric MRI was of real importance in improving the detection, localization and staging of PCa. Moreover, MRI has been useful for lesion targeting within the prostate, as it is used in the guidance of prostate biopsies, by means of cognitive registration, MRI-ultrasound fusion guidance or direct in-bore MRI-guidance. With regard to PCa therapies, MRI is used for precise probe placement into the lesion and to accurately monitor the treatment in real-time. Moreover, advances in MR-compatible thermal ablation allow for noninvasive real-time temperature mapping during treatment. In this review, we present an overview of the current status of MRI-guided therapies in PCa, focusing on cryoablation, focal laser ablation, high intensity focused ultrasound and transurethral ultrasound ablation. We explain the important role of MRI in the evaluation of the completeness of the ablation and during follow-up. Finally, we will discuss the challenges and future development inherent to these new technologies.
Collapse
|
3
|
Hatiboglu G, Popeneciu V, Bonekamp D, Burtnyk M, Staruch R, Distler F, Radtke JP, Motsch J, Schlemmer HP, Pahernik S, Nyarangi-Dix J. Single-Center Evaluation of Treatment Success Using Two Different Protocols for MRI-Guided Transurethral Ultrasound Ablation of Localized Prostate Cancer. Front Oncol 2021; 11:782546. [PMID: 34778095 PMCID: PMC8579125 DOI: 10.3389/fonc.2021.782546] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2021] [Accepted: 10/11/2021] [Indexed: 11/13/2022] Open
Abstract
Objectives To assess differences in 24-month oncologic and functional outcomes in men with low to intermediate-risk prostate cancer treated with MRI-guided transurethral ultrasound ablation (TULSA) using intentionally conservative versus intensified treatment parameters. Patients and Methods Patients from a single center involved in two multicenter trials were included in this analysis. This included 14 of 30 patients with Gleason 3 + 3 from a Phase I study using intentionally conservative treatment parameters, and 15 of 115 patients with Gleason ≤ 3 + 4 from a pivotal study using intensified parameters. Follow-up data compared across these cohorts included 12-month biopsy and MRI for all patients, and 24-month PSA, micturition and quality of life (IIEF, IPSS, IPSS-QOL). The prognostic value of baseline parameters and PSA kinetics on 12-month histological recurrence was evaluated by logistic regression. Results 12-month biopsy revealed clinically significant residual disease in 4 (29%) and 2 (14%) patients from the Phase I and pivotal studies, respectively. PSA nadir was 0.7 ng/ml for Phase I and 0.5 ng/ml for pivotal study patients. Patient age at diagnosis, use of MRI fusion/systematic prostate biopsy, number of obtained cores at initial biopsy, PSA course, and PSA nadir were identified as prognostic factors for treatment success. All but one patient from each cohort maintained erection firmness sufficient for penetration. No cases of pad use were reported at 24 months. There were no Grade 4 or higher adverse events, and no late toxicity related to the procedure. Conclusion Two-year follow-up demonstrated the efficacy of TULSA for the treatment of localized prostate cancer, and the durability of PSA and functional outcomes. Intensifying treatment parameters in the pivotal trial had no impact on safety or functional outcomes through 24 months, while reducing the recurrence rate for clinically significant disease. Careful patient selection by MRI fusion/systematic prostate biopsy and adequate follow-up through routine 12-month biopsy are recommended.
Collapse
Affiliation(s)
- Gencay Hatiboglu
- Department of Urology, University of Heidelberg, Heidelberg, Germany
| | | | - David Bonekamp
- German Cancer Research Center Deutsches Krebsforschungszentrum (DKFZ), Heidelberg, Germany
| | | | | | - Florian Distler
- Department of Urology, University of Heidelberg, Heidelberg, Germany
| | | | - Johann Motsch
- Department of Anaesthesiology, University of Heidelberg, Heidelberg, Germany
| | - Heinz Peter Schlemmer
- German Cancer Research Center Deutsches Krebsforschungszentrum (DKFZ), Heidelberg, Germany
| | - Sascha Pahernik
- Department of Urology, University of Heidelberg, Heidelberg, Germany
| | | |
Collapse
|
4
|
Kok HP, Cressman ENK, Ceelen W, Brace CL, Ivkov R, Grüll H, Ter Haar G, Wust P, Crezee J. Heating technology for malignant tumors: a review. Int J Hyperthermia 2021; 37:711-741. [PMID: 32579419 DOI: 10.1080/02656736.2020.1779357] [Citation(s) in RCA: 147] [Impact Index Per Article: 49.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
The therapeutic application of heat is very effective in cancer treatment. Both hyperthermia, i.e., heating to 39-45 °C to induce sensitization to radiotherapy and chemotherapy, and thermal ablation, where temperatures beyond 50 °C destroy tumor cells directly are frequently applied in the clinic. Achievement of an effective treatment requires high quality heating equipment, precise thermal dosimetry, and adequate quality assurance. Several types of devices, antennas and heating or power delivery systems have been proposed and developed in recent decades. These vary considerably in technique, heating depth, ability to focus, and in the size of the heating focus. Clinically used heating techniques involve electromagnetic and ultrasonic heating, hyperthermic perfusion and conductive heating. Depending on clinical objectives and available technology, thermal therapies can be subdivided into three broad categories: local, locoregional, or whole body heating. Clinically used local heating techniques include interstitial hyperthermia and ablation, high intensity focused ultrasound (HIFU), scanned focused ultrasound (SFUS), electroporation, nanoparticle heating, intraluminal heating and superficial heating. Locoregional heating techniques include phased array systems, capacitive systems and isolated perfusion. Whole body techniques focus on prevention of heat loss supplemented with energy deposition in the body, e.g., by infrared radiation. This review presents an overview of clinical hyperthermia and ablation devices used for local, locoregional, and whole body therapy. Proven and experimental clinical applications of thermal ablation and hyperthermia are listed. Methods for temperature measurement and the role of treatment planning to control treatments are discussed briefly, as well as future perspectives for heating technology for the treatment of tumors.
Collapse
Affiliation(s)
- H Petra Kok
- Department of Radiation Oncology, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| | - Erik N K Cressman
- Department of Interventional Radiology, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - Wim Ceelen
- Department of GI Surgery, Ghent University Hospital, Ghent, Belgium
| | - Christopher L Brace
- Department of Radiology and Biomedical Engineering, University of Wisconsin-Madison, Madison, WI, USA
| | - Robert Ivkov
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Baltimore, MD, USA.,Department of Oncology, Johns Hopkins University School of Medicine, Baltimore, MD, USA.,Department of Mechanical Engineering, Whiting School of Engineering, Johns Hopkins University, Baltimore, MD, USA.,Department of Materials Science and Engineering, Whiting School of Engineering, Johns Hopkins University, Baltimore, MD, USA
| | - Holger Grüll
- Department of Diagnostic and Interventional Radiology, Faculty of Medicine, University Hospital of Cologne, University of Cologne, Cologne, Germany
| | - Gail Ter Haar
- Department of Physics, The Institute of Cancer Research, London, UK
| | - Peter Wust
- Department of Radiation Oncology, Charité Universitätsmedizin Berlin, Berlin, Germany
| | - Johannes Crezee
- Department of Radiation Oncology, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| |
Collapse
|
5
|
Nair SM, Stern N, Dewar M, Siddiqui K, Smith E, Gomez JA, Moussa M, Chin JL. Salvage open radical prostatectomy for recurrent prostate cancer following MRI-guided transurethral ultrasound ablation (TULSA) of the prostate: feasibility and efficacy. Scand J Urol 2020; 54:215-219. [PMID: 32308085 DOI: 10.1080/21681805.2020.1752795] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
Introduction: MRI-guided transurethral ultrasound ablation (TULSA) is a novel modality for minimally invasive ablation in patients with localised prostate cancer (PCa). A multi-national Phase 1 (30 patients) and subsequent Phase 2 (115 patients) study showed TULSA to be feasible, safe and well tolerated. However, technical viability and safety of salvage prostatectomy for those who failed TULSA is unclear. Herein, we report the feasibility and morbidity of salvage radical prostatectomy (sRP) post-TULSA.Methods: Four patients with biopsy-proven residual cancer following TULSA underwent open retropubic sRP within 39 months of TULSA. Peri-and post-operative morbidity were reported. Detailed histopathologic assessment is reported.Results: Median follow-up was 43 months after sRP. Mean operating times, blood loss, and length of stay were 210 min, 866 ml, and 3.5 days, respectively. Intraoperative finding of some fibrotic reaction of endopelvic and Denonvilliers fascia was characteristic. There were no perioperative complications. Whole-mount pathology sections showed one pT2b and three pT3a, suggesting under-staging pre-TULSA. Location of disease was compatible with persistent cancer mostly in the untreated peripheral safety region. One man received an artificial urinary sphincter. All men experienced erectile dysfunction responsive to treatment. Two patients with positive surgical margins had PSA progression requiring salvage radiation, with one requiring long-term androgen deprivation therapy.Conclusions: RP is a viable and safe salvage option if TULSA fails. Technical difficulty and perioperative morbidity were negligible and attributable to minimal peri-prostatic reaction from TULSA.
Collapse
Affiliation(s)
- Shiva Madhwan Nair
- Division of Urology, Department of Surgery, Western University, London, ON, Canada
| | - Noah Stern
- Division of Urology, Department of Surgery, Western University, London, ON, Canada
| | | | - Khurram Siddiqui
- Department of Surgery, Sultan Qaboos University Hospital, Muscat, Oman
| | | | - Jose A Gomez
- Department of Pathology, Western University, London, ON, Canada
| | | | - Joseph L Chin
- Division of Urology, Department of Surgery, Western University, London, ON, Canada
| |
Collapse
|
6
|
Adams MS, Diederich CJ. Deployable cylindrical phased-array applicator mimicking a concentric-ring configuration for minimally-invasive delivery of therapeutic ultrasound. Phys Med Biol 2019; 64:125001. [PMID: 31108478 DOI: 10.1088/1361-6560/ab2318] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
A novel design for a deployable catheter-based ultrasound applicator for endoluminal and laparoscopic intervention is introduced. By combining a 1D cylindrical ring phased array with an expandable paraboloid or conical-shaped balloon-based reflector, the applicator can be controllably collapsed for compact delivery and deployed to mimic a forward-firing larger diameter concentric ring array with tight focusing and electronic steering capabilities in depth. Comprehensive acoustic and biothermal parametric studies were employed to characterize the capabilities of the applicator design as a function of transducer dimensions, phased array configuration, and balloon reflector geometry. Modeling results indicate that practical balloon sizes (43-57 mm expanded diameter), transducer array configurations (e.g. 1.5 MHz, 10 mm OD × 20 mm length, 8 or 16 array elements), and sonication durations (30 s) are capable of producing spatially-localized acoustic intensity focal patterns and ablative thermal lesions (width: 2.8-4.8 mm; length: 5.3-40.1 mm) in generalized soft tissue across a 5-100 mm depth range. Larger focal intensity gain magnitudes and narrower focal dimensions are attainable using paraboloid-shaped balloon reflectors with natural geometric focal depths of 25-55 mm, whereas conical-shaped reflectors (angled 45-55°) produce broader foci and extend electronic steering range in depth. A proof-of-concept phased array applicator assembly was fabricated and characterized using hydrophone and radiation force balance measurements and demonstrated good agreement with simulation. The results of this study suggest that combining small diameter cylindrical phased arrays with expandable balloon reflectors can enhance minimally invasive ultrasound-based intervention by augmenting achievable focal gains and penetration depths with dynamic adjustment of treatment depth.
Collapse
|
7
|
Magnetic resonance imaging-guided transurethral ultrasound ablation of prostate tissue in patients with localized prostate cancer: single-center evaluation of 6-month treatment safety and functional outcomes of intensified treatment parameters. World J Urol 2019; 38:343-350. [DOI: 10.1007/s00345-019-02784-w] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2019] [Accepted: 04/25/2019] [Indexed: 10/26/2022] Open
|
8
|
Hynynen K, Jones RM. Image-guided ultrasound phased arrays are a disruptive technology for non-invasive therapy. Phys Med Biol 2016; 61:R206-48. [PMID: 27494561 PMCID: PMC5022373 DOI: 10.1088/0031-9155/61/17/r206] [Citation(s) in RCA: 78] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Focused ultrasound offers a non-invasive way of depositing acoustic energy deep into the body, which can be harnessed for a broad spectrum of therapeutic purposes, including tissue ablation, the targeting of therapeutic agents, and stem cell delivery. Phased array transducers enable electronic control over the beam geometry and direction, and can be tailored to provide optimal energy deposition patterns for a given therapeutic application. Their use in combination with modern medical imaging for therapy guidance allows precise targeting, online monitoring, and post-treatment evaluation of the ultrasound-mediated bioeffects. In the past there have been some technical obstacles hindering the construction of large aperture, high-power, densely-populated phased arrays and, as a result, they have not been fully exploited for therapy delivery to date. However, recent research has made the construction of such arrays feasible, and it is expected that their continued development will both greatly improve the safety and efficacy of existing ultrasound therapies as well as enable treatments that are not currently possible with existing technology. This review will summarize the basic principles, current statures, and future potential of image-guided ultrasound phased arrays for therapy.
Collapse
Affiliation(s)
- Kullervo Hynynen
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Canada. Department of Medical Biophysics, University of Toronto, Toronto, Canada. Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Canada
| | | |
Collapse
|
9
|
Tillander M, Hokland S, Koskela J, Dam H, Andersen NP, Pedersen M, Tanderup K, Ylihautala M, Köhler M. High intensity focused ultrasound induced
in vivo
large volume hyperthermia under 3D MRI temperature control. Med Phys 2016; 43:1539-49. [DOI: 10.1118/1.4942378] [Citation(s) in RCA: 45] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023] Open
Affiliation(s)
| | - Steffen Hokland
- Department of Clinical Medicine, Aarhus University Hospital, Aarhus 8000, Denmark
| | | | - Høgni Dam
- Department of Clinical Medicine, Aarhus University Hospital, Aarhus 8000, Denmark
| | - Niels Peter Andersen
- Department of Clinical Medicine, Aarhus University Hospital, Aarhus 8000, Denmark
| | - Michael Pedersen
- Department of Clinical Medicine, Aarhus University Hospital, Aarhus 8000, Denmark
| | - Kari Tanderup
- Department of Clinical Medicine, Aarhus University Hospital, Aarhus 8000, Denmark
| | | | - Max Köhler
- MR‐Therapy, Philips Healthcare, Uusimaa 01510, Finland
| |
Collapse
|
10
|
Adams MS, Scott SJ, Salgaonkar VA, Sommer G, Diederich CJ. Thermal therapy of pancreatic tumours using endoluminal ultrasound: Parametric and patient-specific modelling. Int J Hyperthermia 2016; 32:97-111. [PMID: 27097663 DOI: 10.3109/02656736.2015.1119892] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
Abstract
PURPOSE The aim of this study is to investigate endoluminal ultrasound applicator configurations for volumetric thermal ablation and hyperthermia of pancreatic tumours using 3D acoustic and biothermal finite element models. MATERIALS AND METHODS Parametric studies compared endoluminal heating performance for varying applicator transducer configurations (planar, curvilinear-focused, or radial-diverging), frequencies (1-5 MHz), and anatomical conditions. Patient-specific pancreatic head and body tumour models were used to evaluate feasibility of generating hyperthermia and thermal ablation using an applicator positioned in the duodenal or stomach lumen. Temperature and thermal dose were calculated to define ablation (> 240 EM(43 °C)) and moderate hyperthermia (40-45 °C) boundaries, and to assess sparing of sensitive tissues. Proportional-integral control was incorporated to regulate maximum temperature to 70-80 °C for ablation and 45 °C for hyperthermia in target regions. RESULTS Parametric studies indicated that 1-3 MHz planar transducers are the most suitable for volumetric ablation, producing 5-8 cm(3) lesion volumes for a stationary 5-min sonication. Curvilinear-focused geometries produce more localised ablation to 20-45 mm depth from the GI tract and enhance thermal sparing (T(max) < 42 °C) of the luminal wall. Patient anatomy simulations show feasibility in ablating 60.1-92.9% of head/body tumour volumes (4.3-37.2 cm(3)) with dose < 15 EM(43 °C) in the luminal wall for 18-48 min treatment durations, using 1-3 applicator placements in GI lumen. For hyperthermia, planar and radial-diverging transducers could maintain up to 8 cm(3) and 15 cm(3) of tissue, respectively, between 40-45 °C for a single applicator placement. CONCLUSIONS Modelling studies indicate the feasibility of endoluminal ultrasound for volumetric thermal ablation or hyperthermia treatment of pancreatic tumour tissue.
Collapse
Affiliation(s)
- Matthew S Adams
- a Thermal Therapy Research Group, University of California , San Francisco , California .,b University of California, Berkeley - University of California, San Francisco Graduate Program in Bioengineering , California , and
| | - Serena J Scott
- a Thermal Therapy Research Group, University of California , San Francisco , California
| | - Vasant A Salgaonkar
- a Thermal Therapy Research Group, University of California , San Francisco , California
| | - Graham Sommer
- c Stanford Medical Center , Stanford , California , USA
| | - Chris J Diederich
- a Thermal Therapy Research Group, University of California , San Francisco , California .,b University of California, Berkeley - University of California, San Francisco Graduate Program in Bioengineering , California , and
| |
Collapse
|
11
|
Chin JL, Billia M, Relle J, Roethke MC, Popeneciu IV, Kuru TH, Hatiboglu G, Mueller-Wolf MB, Motsch J, Romagnoli C, Kassam Z, Harle CC, Hafron J, Nandalur KR, Chronik BA, Burtnyk M, Schlemmer HP, Pahernik S. Magnetic Resonance Imaging-Guided Transurethral Ultrasound Ablation of Prostate Tissue in Patients with Localized Prostate Cancer: A Prospective Phase 1 Clinical Trial. Eur Urol 2016; 70:447-55. [PMID: 26777228 DOI: 10.1016/j.eururo.2015.12.029] [Citation(s) in RCA: 60] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2015] [Accepted: 12/16/2015] [Indexed: 02/07/2023]
Abstract
BACKGROUND Magnetic resonance imaging-guided transurethral ultrasound ablation (MRI-TULSA) is a novel minimally invasive technology for ablating prostate tissue, potentially offering good disease control of localized cancer and low morbidity. OBJECTIVE To determine the clinical safety and feasibility of MRI-TULSA for whole-gland prostate ablation in a primary treatment setting of localized prostate cancer (PCa). DESIGN, SETTING, AND PARTICIPANTS A single-arm prospective phase 1 study was performed at three tertiary referral centers in Canada, Germany, and the United States. Thirty patients (median age: 69 yr; interquartile range [IQR]: 67-71 yr) with biopsy-proven low-risk (80%) and intermediate-risk (20%) PCa were treated and followed for 12 mo. INTERVENTION MRI-TULSA treatment was delivered with the therapeutic intent of conservative whole-gland ablation including 3-mm safety margins and 10% residual viable prostate expected around the capsule. OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS Primary end points were safety (adverse events) and feasibility (technical accuracy and precision of conformal thermal ablation). Exploratory outcomes included quality of life, prostate-specific antigen (PSA), and biopsy at 12 mo. RESULTS AND LIMITATIONS Median treatment time was 36min (IQR: 26-44) and prostate volume was 44ml (IQR: 38-48). Spatial control of thermal ablation was ±1.3mm on MRI thermometry. Common Terminology Criteria for Adverse Events included hematuria (43% grade [G] 1; 6.7% G2), urinary tract infections (33% G2), acute urinary retention (10% G1; 17% G2), and epididymitis (3.3% G3). There were no rectal injuries. Median pretreatment International Prostate Symptom Score 8 (IQR: 5-13) returned to 6 (IQR: 4-10) at 3 mo (mean change: -2; 95% confidence interval [CI], -4 to 1). Median pretreatment International Index of Erectile Function 13 (IQR: 6-28) recovered to 13 (IQR: 5-25) at 12 mo (mean change: -1; 95% CI, -5 to 3). Median PSA decreased 87% at 1 mo and was stable at 0.8 ng/ml (IQR: 0.6-1.1) to 12 mo. Positive biopsies showed 61% reduction in total cancer length, clinically significant disease in 9 of 29 patients (31%; 95% CI, 15-51), and any disease in 16 of 29 patients (55%; 95% CI, 36-74). CONCLUSIONS MRI-TULSA was feasible, safe, and technically precise for whole-gland prostate ablation in patients with localized PCa. Phase 1 data are sufficiently compelling to study MRI-TULSA further in a larger prospective trial with reduced safety margins. PATIENT SUMMARY We used magnetic resonance imaging-guided transurethral ultrasound to heat and ablate the prostate in men with prostate cancer. We showed that the treatment can be targeted within a narrow range (1mm) and has a well-tolerated side effect profile. A larger study is under way. TRIAL REGISTRATION NCT01686958, DRKS00005311.
Collapse
Affiliation(s)
- Joseph L Chin
- University of Western Ontario, London Health Sciences Centre, London, ON, Canada.
| | - Michele Billia
- University of Western Ontario, London Health Sciences Centre, London, ON, Canada
| | | | | | | | - Timur H Kuru
- University Hospital Heidelberg, Heidelberg, Germany
| | | | | | | | - Cesare Romagnoli
- University of Western Ontario, London Health Sciences Centre, London, ON, Canada
| | - Zahra Kassam
- University of Western Ontario, London Health Sciences Centre, London, ON, Canada
| | - Christopher C Harle
- University of Western Ontario, London Health Sciences Centre, London, ON, Canada
| | | | | | - Blaine A Chronik
- University of Western Ontario, London Health Sciences Centre, London, ON, Canada
| | | | | | | |
Collapse
|
12
|
Abstract
Advances in medical imaging have enabled the development of new minimally and completely noninvasive therapies that produce a desired biological effect in a target, such as a tumor, with minimal damage to the surrounding tissue. One means of noninvasively achieving bioeffects in tissue is the use of ultrasound to generate heat. Specialized ultrasound transducers can be used to generate focal regions of heating non invasively, without inserting anything into the body or affecting the tissue outside the target region. Ultrasound thermal therapy can be used with magnetic resonance (MR) imaging (MRI) guidance and MRI temperature feedback to automatically control temperature distributions during heating, producing accurate thermal lesions, or maintaining optimal conditions to enhance drug delivery.
Collapse
|
13
|
Odéen H, de Bever J, Almquist S, Farrer A, Todd N, Payne A, Snell JW, Christensen DA, Parker DL. Treatment envelope evaluation in transcranial magnetic resonance-guided focused ultrasound utilizing 3D MR thermometry. J Ther Ultrasound 2014; 2:19. [PMID: 25343028 PMCID: PMC4199783 DOI: 10.1186/2050-5736-2-19] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2014] [Accepted: 09/17/2014] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Current clinical targets for transcranial magnetic resonance-guided focused ultrasound (tcMRgFUS) are all located close to the geometric center of the skull convexity, which minimizes challenges related to focusing the ultrasound through the skull bone. Non-central targets will have to be reached to treat a wider variety of neurological disorders and solid tumors. Treatment envelope studies utilizing two-dimensional (2D) magnetic resonance (MR) thermometry have previously been performed to determine the regions in which therapeutic levels of FUS can currently be delivered. Since 2D MR thermometry was used, very limited information about unintended heating in near-field tissue/bone interfaces could be deduced. METHODS In this paper, we present a proof-of-concept treatment envelope study with three-dimensional (3D) MR thermometry monitoring of FUS heatings performed in a phantom and a lamb model. While the moderate-sized transducer used was not designed for transcranial geometries, the 3D temperature maps enable monitoring of the entire sonication field of view, including both the focal spot and near-field tissue/bone interfaces, for full characterization of all heating that may occur. 3D MR thermometry is achieved by a combination of k-space subsampling and a previously described temporally constrained reconstruction method. RESULTS We present two different types of treatment envelopes. The first is based only on the focal spot heating-the type that can be derived from 2D MR thermometry. The second type is based on the relative near-field heating and is calculated as the ratio between the focal spot heating and the near-field heating. This utilizes the full 3D MR thermometry data achieved in this study. CONCLUSIONS It is shown that 3D MR thermometry can be used to improve the safety assessment in treatment envelope evaluations. Using a non-optimal transducer, it is shown that some regions where therapeutic levels of FUS can be delivered, as suggested by the first type of envelope, are not necessarily safely treated due to the amount of unintended near-field heating occurring. The results presented in this study highlight the need for 3D MR thermometry in tcMRgFUS.
Collapse
Affiliation(s)
- Henrik Odéen
- Utah Center for Advanced Imaging Research, Department of Radiology, University of Utah, Salt Lake City, Utah 84108, USA
- Department of Physics and Astronomy, University of Utah, Salt Lake City, Utah 84112, USA
| | - Joshua de Bever
- School of Computing, University of Utah, Salt Lake City, Utah 84112, USA
| | - Scott Almquist
- School of Computing, University of Utah, Salt Lake City, Utah 84112, USA
| | - Alexis Farrer
- Department of Bioengineering, University of Utah, Salt Lake City, Utah 84112, USA
| | - Nick Todd
- Utah Center for Advanced Imaging Research, Department of Radiology, University of Utah, Salt Lake City, Utah 84108, USA
| | - Allison Payne
- Utah Center for Advanced Imaging Research, Department of Radiology, University of Utah, Salt Lake City, Utah 84108, USA
| | - John W Snell
- Focused Ultrasound Foundation, Charlottesville, Virginia 22903, USA
- Department of Neurological Surgery, University of Virginia, Charlottesville, Virginia 22908, USA
| | - Douglas A Christensen
- Department of Bioengineering, University of Utah, Salt Lake City, Utah 84112, USA
- Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, Utah 84112, USA
| | - Dennis L Parker
- Utah Center for Advanced Imaging Research, Department of Radiology, University of Utah, Salt Lake City, Utah 84108, USA
| |
Collapse
|
14
|
Goharrizi AY, Kwong RH, Chopra R. A self-tuning adaptive controller for 3-D image-guided ultrasound cancer therapy. IEEE Trans Biomed Eng 2014; 61:911-9. [PMID: 24557692 DOI: 10.1109/tbme.2013.2292559] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
One of the challenges in MRI-controlled hyperthermia cancer treatment for localized tumor is that the tissue properties are dynamic and difficult to measure. Therefore, tuning the optimal gains for a constant gain controller can be challenging. In this paper, a new multi-input single-output adaptive controller strategy is proposed to address these problems. The inputs to the controller block are the frequency, rotation rate, and applied power level of an interstitial applicator, and the output is the boundary temperature during treatment. The time-varying gains of the new controller are updated over time using Lyapunov-based stability analysis. The robustness of the new controller to changes in the parameters of the tissue is investigated and compared to a constant gain controller through simulation studies. Simulations take into account changes in tissue properties and other conditions that may be encountered in a practical clinical situation. Finally, the effectiveness of the proposed controller is validated through an experimental study.
Collapse
|
15
|
|
16
|
Schlesinger D, Benedict S, Diederich C, Gedroyc W, Klibanov A, Larner J. MR-guided focused ultrasound surgery, present and future. Med Phys 2014; 40:080901. [PMID: 23927296 DOI: 10.1118/1.4811136] [Citation(s) in RCA: 82] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
MR-guided focused ultrasound surgery (MRgFUS) is a quickly developing technology with potential applications across a spectrum of indications traditionally within the domain of radiation oncology. Especially for applications where focal treatment is the preferred technique (for example, radiosurgery), MRgFUS has the potential to be a disruptive technology that could shift traditional patterns of care. While currently cleared in the United States for the noninvasive treatment of uterine fibroids and bone metastases, a wide range of clinical trials are currently underway, and the number of publications describing advances in MRgFUS is increasing. However, for MRgFUS to make the transition from a research curiosity to a clinical standard of care, a variety of challenges, technical, financial, clinical, and practical, must be overcome. This installment of the Vision 20∕20 series examines the current status of MRgFUS, focusing on the hurdles the technology faces before it can cross over from a research technique to a standard fixture in the clinic. It then reviews current and near-term technical developments which may overcome these hurdles and allow MRgFUS to break through into clinical practice.
Collapse
Affiliation(s)
- David Schlesinger
- Department of Radiation Oncology, University of Virginia, Charlottesville, Virginia 22908, USA.
| | | | | | | | | | | |
Collapse
|
17
|
Applicators for magnetic resonance-guided ultrasonic ablation of benign prostatic hyperplasia. Invest Radiol 2014; 48:387-94. [PMID: 23462673 DOI: 10.1097/rli.0b013e31827fe91e] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
OBJECTIVES The aims of this study were to evaluate in a canine model applicators designed for ablation of human benign prostatic hyperplasia (BPH) in vivo under magnetic resonance imaging (MRI) guidance, including magnetic resonance thermal imaging (MRTI), determine the ability of MRI techniques to visualize ablative changes in prostate, and evaluate the acute and longer term histologic appearances of prostate tissue ablated during these studies. MATERIALS AND METHODS An MRI-compatible transurethral device incorporating a tubular transducer array with dual 120° sectors was used to ablate canine prostate tissue in vivo, in zones similar to regions of human BPH (enlarged transition zones). Magnetic resonance thermal imaging was used for monitoring of ablation in a 3-T environment, and postablation MRIs were performed to determine the visibility of ablated regions. Three canine prostates were ablated in acute studies, and 2 animals were rescanned before killing at 31 days postablation. Acute and chronic appearances of ablated prostate tissue were evaluated histologically and were correlated with the MRTI and postablation MRI scans. RESULTS It was possible to ablate regions similar in size to enlarged transition zone in human BPH in 6 to 18 minutes. Regions of acute ablation showed a central "heat-fixed" region surrounded by a region of more obvious necrosis with complete disruption of tissue architecture. After 31 days, ablated regions demonstrated complete apparent resorption of ablated tissue with formation of cystic regions containing fluid. The inherent cooling of the urethra using the technique resulted in complete urethral preservation in all cases. CONCLUSIONS Prostatic ablation of zones of size and shape corresponding to human BPH is possible using appropriate transurethral applicators using MRTI, and ablated tissue may be depicted clearly in contrast-enhanced magnetic resonance images. The ability accurately to monitor prostate tissue heating, the apparent resorption of ablated regions over 1 month, and the inherent urethral preservation suggest that the magnetic resonance-guided techniques described are highly promising for the in vivo ablation of symptomatic human BPH.
Collapse
|
18
|
Muller BG, Fütterer JJ, Gupta RT, Katz A, Kirkham A, Kurhanewicz J, Moul JW, Pinto PA, Rastinehad AR, Robertson C, de la Rosette J, Sanchez-Salas R, Jones JS, Ukimura O, Verma S, Wijkstra H, Marberger M. The role of magnetic resonance imaging (MRI) in focal therapy for prostate cancer: recommendations from a consensus panel. BJU Int 2013; 113:218-27. [PMID: 24215670 DOI: 10.1111/bju.12243] [Citation(s) in RCA: 74] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
OBJECTIVE To establish a consensus on the utility of multiparametric magnetic resonance imaging (mpMRI) to identify patients for focal therapy. METHODS Urological surgeons, radiologists, and basic researchers, from Europe and North America participated in a consensus meeting about the use of mpMRI in focal therapy of prostate cancer. The consensus process was face-to-face and specific clinical issues were raised and discussed with agreement sought when possible. All participants are listed among the authors. Topics specifically did not include staging of prostate cancer, but rather identifying the optimal requirements for performing MRI, and the current status of optimally performed mpMRI to (i) determine focality of prostate cancer (e.g. localising small target lesions of ≥0.5 mL), (ii) to monitor and assess the outcome of focal ablation therapies, and (iii) to identify the diagnostic advantages of new MRI methods. In addition, the need for transperineal template saturation biopsies in selecting patients for focal therapy was discussed, if a high quality mpMRI is available. In other words, can mpMRI replace the role of transperineal saturation biopsies in patient selection for focal therapy? RESULTS Consensus was reached on most key aspects of the meeting; however, on definition of the optimal requirements for mpMRI, there was one dissenting voice. mpMRI is the optimum approach to achieve the objectives needed for focal therapy, if made on a high quality machine (3T with/without endorectal coil or 1.5T with endorectal coil) and judged by an experienced radiologist. Structured and standardised reporting of prostate MRI is paramount. State of the art mpMRI is capable of localising small tumours for focal therapy. State of the art mpMRI is the technique of choice for follow-up of focal ablation. CONCLUSIONS The present evidence for MRI in focal therapy is limited. mpMRI is not accurate enough to consistently grade tumour aggressiveness. Template-guided saturation biopsies are no longer necessary when a high quality state of the art mpMRI is available; however, suspicious lesions should always be confirmed by (targeted) biopsy.
Collapse
Affiliation(s)
- Berrend G Muller
- Department of Urology, AMC University Hospital, Amsterdam, the Netherlands
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
19
|
Prakash P, Salgaonkar VA, Diederich CJ. Modelling of endoluminal and interstitial ultrasound hyperthermia and thermal ablation: applications for device design, feedback control and treatment planning. Int J Hyperthermia 2013; 29:296-307. [PMID: 23738697 PMCID: PMC4087028 DOI: 10.3109/02656736.2013.800998] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Endoluminal and catheter-based ultrasound applicators are currently under development and are in clinical use for minimally invasive hyperthermia and thermal ablation of various tissue targets. Computational models play a critical role in device design and optimisation, assessment of therapeutic feasibility and safety, devising treatment monitoring and feedback control strategies, and performing patient-specific treatment planning with this technology. The critical aspects of theoretical modelling, applied specifically to endoluminal and interstitial ultrasound thermotherapy, are reviewed. Principles and practical techniques for modeling acoustic energy deposition, bioheat transfer, thermal tissue damage, and dynamic changes in the physical and physiological state of tissue are reviewed. The integration of these models and applications of simulation techniques in identification of device design parameters, development of real time feedback-control platforms, assessing the quality and safety of treatment delivery strategies, and optimisation of inverse treatment plans are presented.
Collapse
Affiliation(s)
- Punit Prakash
- Department of Electrical and Computer Engineering, Kansas State University, Manhattan, KS 66506, USA.
| | | | | |
Collapse
|
20
|
|
21
|
Goharrizi AY, N'Djin WA, Kwong R, Chopra R. Development of a new control strategy for 3D MRI-controlled interstitial ultrasound cancer therapy. Med Phys 2013; 40:033301. [DOI: 10.1118/1.4793261] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
22
|
Ramsay E, Mougenot C, Köhler M, Bronskill M, Klotz L, Haider MA, Chopra R. MR thermometry in the human prostate gland at 3.0T for transurethral ultrasound therapy. J Magn Reson Imaging 2013; 38:1564-71. [PMID: 23440850 DOI: 10.1002/jmri.24063] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2012] [Accepted: 01/10/2013] [Indexed: 11/05/2022] Open
Abstract
PURPOSE To investigate the spatial, temporal, and temperature resolution of a segmented gradient echo echo-planar imaging (EPI) technique as applied to proton resonance frequency (PRF) shift thermometry at 3 T in the human prostate gland, and to determine appropriate sequence parameters for magnetic resonance imaging (MRI)-controlled transurethral ultrasound thermal therapy. MATERIALS AND METHODS Eleven healthy volunteers (age range 23-58) were scanned at 3 T with a 16-channel torso coil to study the behavior of a gradient echo EPI thermometry sequence. The temperature stability and geometric distortion were assessed for 11 different parameter sets. In a further five volunteers, the prostate T2* was measured. RESULTS For all scan parameters investigated, the temperature standard deviation within the prostate was less than 1°C, while the distortion was less than 1 mm. Temperature stability was best with higher TE values (up to 25 msec), larger voxel sizes and lower EPI factors, but this had to be balanced against requirements for good spatial and temporal resolution. Prostate T2* values ranged from 30-50 msec. CONCLUSION A good balance between temperature stability and temporal/spatial resolution is obtained with TE = 15 msec, voxel size = 1.14 mm, and EPI factor = 9, resulting in a dynamic scan time of 7.2 seconds for the nine slices.
Collapse
Affiliation(s)
- Elizabeth Ramsay
- Physical Sciences, Sunnybrook Research Institute, Toronto, Ontario, Canada
| | | | | | | | | | | | | |
Collapse
|
23
|
Zhou Y. Generation of uniform lesions in high intensity focused ultrasound ablation. ULTRASONICS 2013; 53:495-505. [PMID: 23106859 DOI: 10.1016/j.ultras.2012.09.001] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/04/2012] [Revised: 09/02/2012] [Accepted: 09/02/2012] [Indexed: 06/01/2023]
Abstract
High intensity focused ultrasound (HIFU) is emerging as an effective oncology treatment modality according to the clinical experience in the last decade. The temperature at the focus can reach over 65°C within seconds, denaturing cellular proteins and resulting in coagulative necrosis. HIFU parameters are usually kept the same for each treatment spot in tumor ablation. Because of the thermal diffusion from nearby spots, the lesion size will gradually increase as the HIFU therapy progresses, which leads to insufficient treatment of initial spots and over exposure of later ones. From the viewpoint of the physician, uniform lesions with the least energy exposure and the least energy are preferred in tumor ablation. In this study, an algorithm was developed to determine the number of HIFU pulses delivered to each spot in order to generate uniform lesions that fill the region-of-interest completely. The exposure energies required using different scanning pathways (raster scanning, spiral scanning from the center to the outside, and spiral scanning from the outside to the center), spot spacing (1mm, 2mm, 4mm, and 6mm) and motion time (from 0s to 400s) were compared with each other. It is found that spiral scanning from the outside to the center with spot spacing of 2mm and motion time less than 10s needs the least numbers of pulses or HIFU energy in uniform lesion production with the minimal temperature elevation. In addition, the effects of thermal properties of tissue (i.e., specific heat capacity, convective heat transfer coefficient, and thermal conductivity) on HIFU ablation were investigated in order to determine the HIFU treatment planning for various targets. Uniform lesion production in the transparent gel phantom and ex vivo bovine liver samples using the proposed algorithm proved effective and accord with the simulation for different scanning pathways by an extracorporeal clinical HIFU system. Therefore, dynamically adjusting ultrasound exposure energy can improve the efficacy and safety of HIFU ablation, and the treatment planning depends on the scanning protocol and thermal properties of the target.
Collapse
Affiliation(s)
- Yufeng Zhou
- School of Mechanical & Aerospace Engineering, Nanyang Technological University, 50 Nanyang Ave., Singapore 639798, Singapore.
| |
Collapse
|
24
|
Abstract
OBJECTIVE The purpose of this article is to evaluate MRI-guided therapies and to investigate their feasibility for focal therapy in prostate cancer patients. Relevant articles were retrieved using the PubMed online search engine. CONCLUSION Currently, MRI-guided laser ablation and MRI-guided focused ultrasound are the most promising options for focal treatment of the prostate in patients with prostate cancer. Other techniques-that is, cryosurgery, microwave ablation, and radiofrequency ablation-are, for several and different reasons, less suitable for MRI-guided focal therapy of the prostate.
Collapse
|
25
|
N'djin WA, Burtnyk M, Bronskill M, Chopra R. Investigation of power and frequency for 3D conformal MRI-controlled transurethral ultrasound therapy with a dual frequency multi-element transducer. Int J Hyperthermia 2012; 28:87-104. [PMID: 22235788 DOI: 10.3109/02656736.2011.622343] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Transurethral ultrasound therapy uses real-time magnetic resonance (MR) temperature feedback to enable the 3D control of thermal therapy accurately in a region within the prostate. Previous canine studies showed the feasibility of this method in vivo. The aim of this study was to reduce the procedure time, while maintaining targeting accuracy, by investigating new combinations of treatment parameters. Simulations and validation experiments in gel phantoms were used, with a collection of nine 3D realistic target prostate boundaries obtained from previous preclinical studies, where multi-slice MR images were acquired with the transurethral device in place. Acoustic power and rotation rate were varied based on temperature feedback at the prostate boundary. Maximum acoustic power and rotation rate were optimised interdependently, as a function of prostate radius and transducer operating frequency. The concept of dual frequency transducers was studied, using the fundamental frequency or the third harmonic component depending on the prostate radius. Numerical modelling enabled assessment of the effects of several acoustic parameters on treatment outcomes. The range of treatable prostate radii extended with increasing power, and tended to narrow with decreasing frequency. Reducing the frequency from 8 MHz to 4 MHz or increasing the surface acoustic power from 10 to 20 W/cm(2) led to treatment times shorter by up to 50% under appropriate conditions. A dual frequency configuration of 4/12 MHz with 20 W/cm(2) ultrasound intensity exposure can treat entire prostates up to 40 cm(3) in volume within 30 min. The interdependence between power and frequency may, however, require integrating multi-parametric functions in the controller for future optimisations.
Collapse
Affiliation(s)
- William Apoutou N'djin
- Imaging Research, Sunnybrook Health Sciences Centre, and Department of Medical Biophysics, University of Toronto, Ontario, Canada.
| | | | | | | |
Collapse
|
26
|
Da Rosa MR, Trachtenberg J, Chopra R, Haider MA. Early experience in MRI-guided therapies of prostate cancer: HIFU, laser and photodynamic treatment. Cancer Imaging 2011; 11 Spec No A:S3-8. [PMID: 22187023 PMCID: PMC3266567 DOI: 10.1102/1470-7330.2011.9003] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022] Open
Abstract
Prostate cancer screening has resulted in earlier diagnosis with lower-grade disease, leading to over-detection and over-treatment in a significant number of patients. Current whole-gland radical treatments are associated with significant rates of morbidity. The high prevalence of low-risk disease together with an inability to accurately identify those men harboring more aggressive cancers has led to tremendous research in low-morbidity focal therapies for prostate cancer. This review summarizes the early experiences with focal therapy with emphasis on early applications of laser, high-intensity focuses ultrasound, and photodynamic approaches.
Collapse
Affiliation(s)
- M R Da Rosa
- Department of Medical Imaging, University of Toronto, Toronto, ON, Canada
| | | | | | | |
Collapse
|