1
|
Pyka-Fościak G, Fościak M, Pabijan J, Lis GJ, Litwin JA, Lekka M. Changes in stiffness of the optic nerve and involvement of neurofilament light chains in the course of experimental autoimmune encephalomyelitis, an animal model of multiple sclerosis. Biochim Biophys Acta Mol Basis Dis 2023:166796. [PMID: 37400000 DOI: 10.1016/j.bbadis.2023.166796] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2023] [Revised: 06/23/2023] [Accepted: 06/23/2023] [Indexed: 07/05/2023]
Abstract
Multiple sclerosis and its animal model, experimental autoimmune encephalomyelitis (EAE), are often accompanied by optic neuritis associated with neurofilament disruption. In this study, the stiffness of the optic nerve was investigated by atomic force microscopy (AFM) in mice with induced EAE in the successive phases of the disease: onset, peak, and chronic. AFM results were compared with the intensity of the main pathological processes in the optic nerve: inflammation, demyelination, and axonal loss, as well as with the density of astrocytes, assessed by quantitative histology and immunohistochemistry. Optic nerve tissue and serum levels of neurofilament light chain protein (NEFL) were also examined by immunostaining and ELISA, respectively. The stiffness of the optic nerve in EAE mice was lower than that in control and naïve animals. It increased in the onset and peak phases and sharply decreased in the chronic phase. Serum NEFL level showed similar dynamics, while tissue NEFL level decreased in the onset and peak phases, indicating a leak of NEFL from the optic nerve to body fluids. Inflammation and demyelination gradually increased to reach the maximum in the peak phase of EAE, and inflammation slightly declined in the chronic phase, while demyelination did not. The axonal loss also gradually increased and had the highest level in the chronic phase. Among these processes, demyelination and especially axonal loss most effectively decrease the stiffness of the optic nerve. NEFL level in serum can be regarded as an early indicator of EAE, as it rapidly grows in the onset phase of the disease.
Collapse
Affiliation(s)
- G Pyka-Fościak
- Department of Histology, Jagiellonian University Medical College, Kopernika 7, 31-034 Krakow, Poland.
| | - M Fościak
- Medical Department, Novartis Poland Sp. z o.o., Marynarska 15, 02-674 Warszawa, Poland
| | - J Pabijan
- Department of Biophysical Microstructures, Institute of Nuclear Physics, Polish Academy of Sciences, PL-31342 Krakow, Poland
| | - G J Lis
- Department of Histology, Jagiellonian University Medical College, Kopernika 7, 31-034 Krakow, Poland
| | - J A Litwin
- Department of Histology, Jagiellonian University Medical College, Kopernika 7, 31-034 Krakow, Poland
| | - M Lekka
- Department of Biophysical Microstructures, Institute of Nuclear Physics, Polish Academy of Sciences, PL-31342 Krakow, Poland
| |
Collapse
|
2
|
Bianchi L, Cavarzan F, Ciampitti L, Cremonesi M, Grilli F, Saccomandi P. Thermophysical and mechanical properties of biological tissues as a function of temperature: a systematic literature review. Int J Hyperthermia 2022; 39:297-340. [DOI: 10.1080/02656736.2022.2028908] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022] Open
Affiliation(s)
- Leonardo Bianchi
- Department of Mechanical Engineering, Politecnico di Milano, Milan, Italy
| | - Fabiana Cavarzan
- Department of Mechanical Engineering, Politecnico di Milano, Milan, Italy
| | - Lucia Ciampitti
- Department of Mechanical Engineering, Politecnico di Milano, Milan, Italy
| | - Matteo Cremonesi
- Department of Mechanical Engineering, Politecnico di Milano, Milan, Italy
| | - Francesca Grilli
- Department of Mechanical Engineering, Politecnico di Milano, Milan, Italy
| | - Paola Saccomandi
- Department of Mechanical Engineering, Politecnico di Milano, Milan, Italy
| |
Collapse
|
3
|
Zemła J, Iyer PS, Pyka-Fościak G, Mermod N, Lekka M. Rheological properties of skeletal muscles in a Duchenne muscular dystrophy murine model before and after autologous cell therapy. J Biomech 2021; 128:110770. [PMID: 34628203 DOI: 10.1016/j.jbiomech.2021.110770] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2021] [Revised: 08/30/2021] [Accepted: 09/22/2021] [Indexed: 12/25/2022]
Abstract
Duchenne muscular dystrophy (DMD) is still an incurable muscle degenerative disease; thus, numerous studies focused on novel therapeutic approaches. However, a simple assay of muscle function restoration remains needed. Herein, we used an oscillatory shear rheometer to evaluate changes in rheological properties of mouse muscles (tibialis anterior, TA) and their restoration upon autologous cell therapy by comparing the viscoelastic properties of normal, diseased and treated muscles. Amplitude sweep tests of muscle samples were performed under 20% compression over a range of shear strain between 0.01 and 2% and frequency of 1 rad/s. The samples were tested in plane-plane geometry and horizontal myofiber alignment. Typical linear viscoelastic region (LVER) patterns were found for each muscle type. For healthy muscles, a broad LVER between shear deformations (γ) of 0.013-0.62% was observed. The LVER of DMD mdx/SCID muscles was found at 0.14% to 0.46% shear deformation, and no shear dependence of storage (G') and loss (G") moduli at γ range changing from 0.034% to 0.26% was found for transplanted tissues. G'LVER and G"LVER moduli of healthy muscles were significantly higher than G'LVER and G"LVER of dystrophic tissues. Additionally, muscle resistance assessment by rheometer indicated that muscles transplanted with stem cells restored elastic properties to levels close to those of healthy muscles. Interestingly, histological staining and rheological data indicate that the loss factor is strongly related to structural changes of examined muscles.
Collapse
Affiliation(s)
- Joanna Zemła
- Institute of Nuclear Physics Polish Academy of Sciences, PL-31342 Krakow, Poland.
| | - Pavithra S Iyer
- Institute of Biotechnology and Department of Fundamental Microbiology, University of Lausanne, Lausanne, Switzerland
| | - Grażyna Pyka-Fościak
- Department of Histology, Jagiellonian University Medical College, Kopernika 7, 31-034 Krakow, Poland
| | - Nicolas Mermod
- Institute of Biotechnology and Department of Fundamental Microbiology, University of Lausanne, Lausanne, Switzerland
| | - Małgorzata Lekka
- Institute of Nuclear Physics Polish Academy of Sciences, PL-31342 Krakow, Poland
| |
Collapse
|
4
|
Enhanced precision of real-time control photothermal therapy using cost-effective infrared sensor array and artificial neural network. Comput Biol Med 2021; 141:104960. [PMID: 34776096 DOI: 10.1016/j.compbiomed.2021.104960] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2021] [Revised: 10/14/2021] [Accepted: 10/16/2021] [Indexed: 12/31/2022]
Abstract
Photothermal therapy (PTT) requires tight thermal dose control to achieve tumor ablation with minimal thermal injury on surrounding healthy tissues. In this study, we proposed a real-time closed-loop system for monitoring and controlling the temperature of PTT using a non-contact infrared thermal sensor array and an artificial neural network (ANN) to induce a predetermined area of thermal damage on the tissue. A cost-effective infrared thermal sensor array was used to monitor the temperature development for feedback control during the treatment. The measured and predicted temperatures were used as inputs of fuzzy control logic controllers that were implemented on an embedded platform (Jetson Nano) for real-time thermal control. Three treatment groups (continuous wave = CW, conventional fuzzy logic = C-Fuzzy, and ANN-based predictive fuzzy logic = P-Fuzzy) were examined and compared to investigate the laser heating performance and collect temperature data for ANN model training. The ex vivo experiments validated the efficiency of fuzzy control with temperature method on maintaining the constant interstitial tissue temperature (80 ± 1.4 °C) at a targeted surface of the tissue. The linear relationship between coagulation areas and the treatment time was indicated in this study, with the averaged coagulation rate of 0.0196 cm2/s. A thermal damage area of 1.32 cm2 (diameter ∼1.3 cm) was observed under P-Fuzzy condition for 200 s, which covered the predetermined thermal damage area (diameter ∼1 cm). The integration of real-time feedback temperature control with predictive ANN could be a feasible approach to precisely induce the preset extent of thermal coagulation for treating papillary thyroid microcarcinoma.
Collapse
|
5
|
Traboulsi-Garet B, González-Barnadas A, Camps-Font O, Figueiredo R, Valmaseda-Castellón E. Influence of Different Incision Designs on Flap Extension: A Cadaveric Animal Model. J ORAL IMPLANTOL 2021; 47:395-400. [PMID: 33031545 DOI: 10.1563/aaid-joi-d-20-00026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
It is well known that wound dehiscence is one of the most frequent complications in guided bone regeneration. The main cause of this complication may be a lack of tension-free and primary wound closure. The aim of this study was to evaluate and compare the effect of periosteal releasing incisions (PRI) on the extension of 3 different flap designs: envelope, triangular, and trapezoidal. Twelve pig mandibles were used to quantify extension of the flap designs. The mandibles were equally and randomly distributed into the 3 flap groups. Each mandible was divided into 2 sides: 1 was subjected to a PRI and the other not. The flap was pulled with a force of 1.08 N, and the extension was recorded. The subgroups without PRI showed an average extension of 5.14 mm with no statistically significant differences among them (P = .165). The PRI provided an average extension of 7.37 mm with statistically significant differences among the subgroups (P < .001). The releasing incisions significantly increased flap extension in each flap design. The increase in extension of the trapezoidal flap with PRI was significantly greater than in the other subgroups. In cases where primary closure is required, surgeons should consider performing trapezoidal flaps with PRI in order to reduce tension.
Collapse
Affiliation(s)
| | | | - Octavi Camps-Font
- Faculty of Medicine and Health Sciences, University of Barcelona, Barcelona, Spain
| | - Rui Figueiredo
- Faculty of Medicine and Health Sciences, University of Barcelona, Barcelona, Spain
| | | |
Collapse
|
6
|
Dynamic mechanical characterization and viscoelastic modeling of bovine brain tissue. J Mech Behav Biomed Mater 2020; 114:104204. [PMID: 33218929 DOI: 10.1016/j.jmbbm.2020.104204] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2020] [Revised: 10/23/2020] [Accepted: 11/07/2020] [Indexed: 01/12/2023]
Abstract
Brain tissue is vulnerable and sensitive, predisposed to potential damage under various conditions of mechanical loading. Although its material properties have been investigated extensively, the frequency-dependent viscoelastic characterization is currently limited. Computational models can provide a non-invasive method by which to analyze brain injuries and predict the mechanical response of the tissue. The brain injuries are expected to be induced by dynamic loading, mostly in compression and measurement of dynamic viscoelastic properties are essential to improve the accuracy and variety of finite element simulations on brain tissue. Thus, the aim of this study was to investigate the compressive frequency-dependent properties of brain tissue and present a mathematical model in the frequency domain to capture the tissue behavior based on experimental results. Bovine brain specimens, obtained from four locations of corona radiata, corpus callosum, basal ganglia and cortex, were tested under compression using dynamic mechanical analysis over a range of frequencies between 0.5 and 35 Hz to characterize the regional and directional response of the tissue. The compressive dynamic properties of bovine brain tissue were heterogenous for regions but not sensitive to orientation showing frequency dependent statistical results, with viscoelastic properties increasing with frequency. The mean storage and loss modulus were found to be 12.41 kPa and 5.54 kPa, respectively. The material parameters were obtained using the linear viscoelastic model in the frequency domain and the numeric simulation can capture the compressive mechanical behavior of bovine brain tissue across a range of frequencies. The frequency-dependent viscoelastic characterization of brain tissue will improve the fidelity of the computational models of the head and provide essential information to the prediction and analysis of brain injuries in clinical treatments.
Collapse
|
7
|
Estermann SJ, Pahr DH, Reisinger A. Hyperelastic and viscoelastic characterization of hepatic tissue under uniaxial tension in time and frequency domain. J Mech Behav Biomed Mater 2020; 112:104038. [PMID: 32889334 DOI: 10.1016/j.jmbbm.2020.104038] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2020] [Revised: 08/03/2020] [Accepted: 08/10/2020] [Indexed: 01/28/2023]
Abstract
In order to create accurate anatomical models for medical training and research, mechanical properties of biological tissues need to be studied. However, non-linear and viscoelastic behaviour of most soft biological tissues complicates the evaluation of their mechanical properties. In the current study, a method for measuring hyperelasticity and viscoelasticity of bovine and porcine hepatic parenchyma in tension is presented. First, non-linear stress-stretch curves resulting from ramp loading and unloading, were interpreted based on a hyperelastic framework, using a Veronda-Westmann strain energy function. Strain-specific elastic moduli, such as initial stiffness EI, were thereupon defined in certain parts of the stress-stretch curves. Furthermore, dissipated and stored energy density were calculated. Next, the viscoelastic nature of liver tissue was examined with two different methods: stress relaxation and dynamic cyclic testing. Both tests yielded dissipated and stored energy density, as well as loss tangent (tanδ), storage modulus (E'), and loss modulus (E''). In tension, stress relaxation was experimentally more convenient than dynamic cyclic testing. Thus we considered whether relaxation could be used for approximating the results of the cyclic tests. Regarding the resulting elastic moduli, initial stiffness was similar for porcine and bovine liver (EI∼30kPa), while porcine liver was stiffer for higher strains. Comparing stress relaxation with dynamic cyclic testing, tanδ of porcine and bovine liver was the same for both methods (tanδ=0.05-0.25 at 1 Hz). Storage and loss moduli matched well for bovine, but not as well for porcine tissue. In conclusion, the utilized Veronda-Westmann model was appropriate for representing the hyperelasticity of liver tissue seen in ramp tests. Concerning viscoelasticity, both chosen testing methods - stress relaxation and dynamic cyclic testing - yielded comparable results for E', E'', and tanδ, as long as elasticity non-linearities were heeded. The here presented method provides novel insight into the tensile viscoelastic properties of hepatic tissue, and provides guidelines for convenient evaluation of soft tissue mechanical properties.
Collapse
Affiliation(s)
- Sarah-Jane Estermann
- Department Anatomy and Biomechanics, Karl Landsteiner University of Health Sciences, Dr.-Karl-Dorrek-Straße 30, 3500 Krems an der Donau, Austria; Austrian Center for Medical Innovation and Technology, Viktor Kaplan-Straße 2/1, 2700 Wiener Neustadt, Austria; Institute for Lightweight Design and Structural Biomechanics, TU-Wien, Getreidemarkt 9, 1060 Wien, Austria
| | - Dieter H Pahr
- Department Anatomy and Biomechanics, Karl Landsteiner University of Health Sciences, Dr.-Karl-Dorrek-Straße 30, 3500 Krems an der Donau, Austria; Institute for Lightweight Design and Structural Biomechanics, TU-Wien, Getreidemarkt 9, 1060 Wien, Austria
| | - Andreas Reisinger
- Department Anatomy and Biomechanics, Karl Landsteiner University of Health Sciences, Dr.-Karl-Dorrek-Straße 30, 3500 Krems an der Donau, Austria.
| |
Collapse
|
8
|
Lada E, Anna M, Patrik M, Zbynek T, Miroslav J, Hynek M, Richard P, Sarah L, Vaclav L. Porcine Liver Anatomy Applied to Biomedicine. J Surg Res 2020; 250:70-79. [DOI: 10.1016/j.jss.2019.12.038] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2019] [Revised: 12/16/2019] [Accepted: 12/28/2019] [Indexed: 02/06/2023]
|
9
|
Frequency dependent viscoelastic properties of porcine brain tissue. J Mech Behav Biomed Mater 2020; 102:103460. [DOI: 10.1016/j.jmbbm.2019.103460] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2019] [Revised: 09/24/2019] [Accepted: 09/28/2019] [Indexed: 02/06/2023]
|
10
|
Massalou D, Masson C, Afquir S, Baqué P, Arnoux PJ, Bège T. Influence of gender, age, shelf-life, and conservation method on the biomechanical behavior of colon tissue under dynamic solicitation. Clin Biomech (Bristol, Avon) 2019; 65:34-40. [PMID: 30954683 DOI: 10.1016/j.clinbiomech.2019.03.017] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/04/2018] [Revised: 03/19/2019] [Accepted: 03/27/2019] [Indexed: 02/07/2023]
Abstract
BACKGROUND Data from biomechanical tissue sample studies of the human digestive tract are highly variable. The aim of this study was to investigate 4 factors which could modify the mechanical response of human colonic specimens placed under dynamic solicitation until tissue rupture: gender, age, shelf-life and conservation method. METHODS We performed uniaxial dynamic tests of human colonic specimens. Specimens were taken according to three different protocols: refrigerated cadavers without embalming, embalmed cadavers and fresh colonic tissue. A total of 143 specimens were subjected to tensile tests, at a speed of 1 m s-1. FINDINGS Young's modulus of the different conservation protocols are as follows: embalmed, 3.08 ± 1.99; fresh, 2.97 ± 2.59; and refrigerated 3.17 ± 2.05. The type of conservation does not modify the stiffness of the tissue (p = 0.26) but does modify the stress necessary for rupture (p < 0.001) and the strain required to obtain lesions of the outer layer and the inner layer (p < 0.001 and p < 0.05, respectively). Gender is also a factor responsible for a change in the mechanical response of the colon. The age of the subjects and the shelf-life of the bodies did not represent factors influencing the mechanical behavior of the colon (p > 0.05). INTERPRETATION The mechanical response of the colon tissue showed a biphasic injury process depending on gender and method of preservation. The age and shelf-life of anatomical subjects do not alter the mechanical response of the colon.
Collapse
Affiliation(s)
- D Massalou
- Emergency Surgery Unit, University Hospital of Nice, CHU de Nice Hôpital Pasteur 2, Université de Nice Sophia-Antipolis, France; Biomechanical Applied Laboratory, UMRT24, IFSTTAR, Aix-Marseille University, France.
| | - C Masson
- Biomechanical Applied Laboratory, UMRT24, IFSTTAR, Aix-Marseille University, France.
| | - S Afquir
- Biomechanical Applied Laboratory, UMRT24, IFSTTAR, Aix-Marseille University, France
| | - P Baqué
- Emergency Surgery Unit, University Hospital of Nice, CHU de Nice Hôpital Pasteur 2, Université de Nice Sophia-Antipolis, France.
| | - P-J Arnoux
- Biomechanical Applied Laboratory, UMRT24, IFSTTAR, Aix-Marseille University, France.
| | - T Bège
- Department of Visceral Surgery, AP-HM Hôpital Nord, Aix-Marseille University, France; Biomechanical Applied Laboratory, UMRT24, IFSTTAR, Aix-Marseille University, France.
| |
Collapse
|
11
|
Sensitivity of multifrequency magnetic resonance elastography and diffusion-weighted imaging to cellular and stromal integrity of liver tissue. J Biomech 2019; 88:201-208. [DOI: 10.1016/j.jbiomech.2019.03.037] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2019] [Revised: 03/27/2019] [Accepted: 03/27/2019] [Indexed: 12/16/2022]
|
12
|
Kelly NP, Flood HD, Hoey DA, Kiely PA, Giri SK, Coffey JC, Walsh MT. Direct mechanical characterization of prostate tissue-a systematic review. Prostate 2019; 79:115-125. [PMID: 30225866 DOI: 10.1002/pros.23718] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/30/2018] [Accepted: 08/21/2018] [Indexed: 12/11/2022]
Abstract
BACKGROUND Direct mechanical characterization of tissue is the application of engineering techniques to biological tissue to ascertain stiffness or elasticity, which can change in response to disease states. A number of papers have been published on the application of these techniques to prostate tissue with a range of results reported. There is a marked variability in the results depending on testing techniques and disease state of the prostate tissue. We aimed to clarify the utility of direct mechanical characterization of prostate tissue in identifying disease states. METHODS A systematic review of the published literature regarding direct mechanical characterization of prostate tissue was undertaking according to PRISMA guidelines. RESULTS A variety of testing methods have been used, including compression, indentation, and tensile testing, as well as some indirect testing techniques, such as shear-wave elastography. There is strong evidence of significant stiffness differences between cancerous and non-cancerous prostate tissue, as well as correlations with prostate cancer stage. There is a correlation with increasing prostate stiffness and increasing lower urinary tract symptoms in patients with benign prostate hyperplasia. There is a wide variation in the testing methods and protocols used in the literature making direct comparison between papers difficult. Most studies utilise ex-vivo or cadaveric tissue, while none incorporate in vivo testing. CONCLUSION Direct mechanical assessment of prostate tissue permits a better understanding of the pathological and physiological changes that are occurring within the tissue. Further work is needed to include prospective and in vivo data to aid medical device design and investigate non-surgical methods of managing prostate disease.
Collapse
Affiliation(s)
- Niall P Kelly
- Department of Urology, University Hospital Limerick, Limerick, Ireland
- Graduate Entry Medical School, University of Limerick, Limerick, Ireland
- BioScience BioEngineering Research (BioSciBER), Health Research Institute (HRI), Bernal Institute, School of Engineering, University of Limerick, Limerick, Ireland
| | - Hugh D Flood
- Department of Urology, University Hospital Limerick, Limerick, Ireland
| | - David A Hoey
- Trinity Centre for Bioengineering, Trinity Biomedical Sciences Institute, Department of Mechanical and Manufacturing Engineering, School of Engineering, Trinity College Dublin, Dublin, Ireland
- Advanced Materials and Bioengineering Research Centre, Trinity College Dublin & RCSI, Dublin, Ireland
| | - Patrick A Kiely
- Graduate Entry Medical School, University of Limerick, Limerick, Ireland
- BioScience BioEngineering Research (BioSciBER), Health Research Institute (HRI), Bernal Institute, School of Engineering, University of Limerick, Limerick, Ireland
| | - Subhasis K Giri
- Department of Urology, University Hospital Limerick, Limerick, Ireland
| | - J Calvin Coffey
- Graduate Entry Medical School, University of Limerick, Limerick, Ireland
| | - Michael T Walsh
- BioScience BioEngineering Research (BioSciBER), Health Research Institute (HRI), Bernal Institute, School of Engineering, University of Limerick, Limerick, Ireland
| |
Collapse
|
13
|
Qiu S, Zhao X, Chen J, Zeng J, Chen S, Chen L, Meng Y, Liu B, Shan H, Gao M, Feng Y. Characterizing viscoelastic properties of breast cancer tissue in a mouse model using indentation. J Biomech 2018; 69:81-89. [DOI: 10.1016/j.jbiomech.2018.01.007] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2017] [Revised: 01/06/2018] [Accepted: 01/08/2018] [Indexed: 10/24/2022]
|
14
|
Effects of freezing, fixation and dehydration on surface roughness properties of porcine left anterior descending coronary arteries. Micron 2017; 101:78-86. [PMID: 28662414 DOI: 10.1016/j.micron.2017.06.009] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2017] [Revised: 06/15/2017] [Accepted: 06/19/2017] [Indexed: 12/23/2022]
Abstract
BACKGROUND To allow measurements of surface roughness to be made of coronary arteries using various imaging techniques, chemical processing, such as fixation and dehydration, is commonly used. Standard protocols suggest storing fresh biological tissue at -40°C. The aim of this study was to quantify the changes caused by freezing and chemical processing to the surface roughness measurements of coronary arteries, and to determine whether correction factors are needed for surface roughness measurements of coronary arteries following chemical processes typically used before imaging these arteries. METHODS Porcine left anterior descending coronary arteries were dissected ex vivo. Surface roughness was then calculated following three-dimensional reconstruction of surface images obtained using an optical microscope. Surface roughness was measured before and after a freeze cycle to assess changes during freezing, after chemical fixation, and again after dehydration, to determine changes during these steps of chemical processing. RESULTS No significant difference was caused due to the freeze cycle (p>0.05). There was no significant difference in the longitudinally measured surface roughness (RaL=0.99±0.39μm; p>0.05) of coronary arteries following fixation and dehydration either. However, the circumferentially measured surface roughness increased significantly following a combined method of processing (RaC=1.36±0.40, compared 1.98±0.27μm, respectively; p<0.05). A correction factor can compensate for the change RaCβ=RaC1+0.46in RaC due to processing of tissue, Where RaCβ, the corrected RaC, had a mean of 1.31±0.21μm. CONCLUSIONS Independently, freezing, fixation and dehydration do not alter the surface roughness of coronary arteries. Combined, however, fixation and dehydration significantly increase the circumferential, but not longitudinal, surface roughness of coronary arteries.
Collapse
|
15
|
Effect of freezing storage time on the elastic and viscous properties of the porcine TMJ disc. J Mech Behav Biomed Mater 2017; 71:314-319. [DOI: 10.1016/j.jmbbm.2017.03.035] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2017] [Revised: 03/21/2017] [Accepted: 03/31/2017] [Indexed: 11/17/2022]
|
16
|
Burton HE, Freij JM, Espino DM. Dynamic Viscoelasticity and Surface Properties of Porcine Left Anterior Descending Coronary Arteries. Cardiovasc Eng Technol 2017; 8:41-56. [PMID: 27957718 PMCID: PMC5320017 DOI: 10.1007/s13239-016-0288-4] [Citation(s) in RCA: 37] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/03/2016] [Accepted: 11/30/2016] [Indexed: 12/12/2022]
Abstract
The aim of this study was, for the first time, to measure and compare quantitatively the viscoelastic properties and surface roughness of coronary arteries. Porcine left anterior descending coronary arteries were dissected ex vivo. Viscoelastic properties were measured longitudinally using dynamic mechanical analysis, for a range of frequencies from 0.5 to 10 Hz. Surface roughness was calculated following three-dimensional reconstructed of surface images obtained using an optical microscope. Storage modulus ranged from 14.47 to 25.82 MPa, and was found to be frequency-dependent, decreasing as the frequency increased. Storage was greater than the loss modulus, with the latter found to be frequency-independent with a mean value of 2.10 ± 0.33 MPa. The circumferential surface roughness was significantly greater (p < 0.05) than the longitudinal surface roughness, ranging from 0.73 to 2.83 and 0.35 to 0.92 µm, respectively. However, if surface roughness values were corrected for shrinkage during processing, circumferential and longitudinal surface roughness were not significantly different (1.04 ± 0.47, 0.89 ± 0.27 µm, respectively; p > 0.05). No correlation was found between the viscoelastic properties and surface roughness. It is feasible to quantitatively measure the viscoelastic properties of coronary arteries and the roughness of their endothelial surface.
Collapse
Affiliation(s)
- Hanna E. Burton
- Department of Mechanical Engineering, University of Birmingham, Birmingham, B15 2TT UK
| | - Jenny M. Freij
- Department of Mechanical Engineering, University of Birmingham, Birmingham, B15 2TT UK
| | - Daniel M. Espino
- Department of Mechanical Engineering, University of Birmingham, Birmingham, B15 2TT UK
| |
Collapse
|
17
|
Wex C, Arndt S, Stoll A, Bruns C, Kupriyanova Y. Isotropic incompressible hyperelastic models for modelling the mechanical behaviour of biological tissues: a review. ACTA ACUST UNITED AC 2015; 60:577-92. [DOI: 10.1515/bmt-2014-0146] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2014] [Accepted: 05/07/2015] [Indexed: 11/15/2022]
Abstract
AbstractModelling the mechanical behaviour of biological tissues is of vital importance for clinical applications. It is necessary for surgery simulation, tissue engineering, finite element modelling of soft tissues, etc. The theory of linear elasticity is frequently used to characterise biological tissues; however, the theory of nonlinear elasticity using hyperelastic models, describes accurately the nonlinear tissue response under large strains. The aim of this study is to provide a review of constitutive equations based on the continuum mechanics approach for modelling the rate-independent mechanical behaviour of homogeneous, isotropic and incompressible biological materials. The hyperelastic approach postulates an existence of the strain energy function – a scalar function per unit reference volume, which relates the displacement of the tissue to their corresponding stress values. The most popular form of the strain energy functions as Neo-Hookean, Mooney-Rivlin, Ogden, Yeoh, Fung-Demiray, Veronda-Westmann, Arruda-Boyce, Gent and their modifications are described and discussed considering their ability to analytically characterise the mechanical behaviour of biological tissues. The review provides a complete and detailed analysis of the strain energy functions used for modelling the rate-independent mechanical behaviour of soft biological tissues such as liver, kidney, spleen, brain, breast, etc.
Collapse
|
18
|
Wex C, Fröhlich M, Brandstädter K, Bruns C, Stoll A. Experimental analysis of the mechanical behavior of the viscoelastic porcine pancreas and preliminary case study on the human pancreas. J Mech Behav Biomed Mater 2014; 41:199-207. [PMID: 25460416 DOI: 10.1016/j.jmbbm.2014.10.013] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2014] [Revised: 10/20/2014] [Accepted: 10/21/2014] [Indexed: 02/06/2023]
Abstract
The aim of this article is to study the mechanical properties of the pancreas. Up to now, the mechanical properties of the pancreas are not sufficiently characterized. The possibility of intraoperative mechanical testing of pathological pancreata will allow the classification of pancreatic diseases in the future. The application of mechanical parameters instead of the intraoperative frozen section analysis shortens waiting times in the operating room. This study proves the general applicability of shear rheology for the determination of the mechanical properties of pancreas and the assessment of graft quality for transplantation. Porcine and human pancreas samples were examined ex vivo and a nonlinear viscoelastic behavior was observed. Pancreas was found to be more viscous than liver but both abdominal organs showed a similar flow behavior. The shear deformation dependence of healthy human pancreas was similar to porcine pancreas. An increase in the post-mortem time led to an increase in the complex modulus for a post-mortem time up to 8.5 days. Histological investigations showed that an increased amount of collagen coincides with the stiffening of the pancreatic tissue.
Collapse
Affiliation(s)
- C Wex
- Clinic for General, Visceral and Vascular Surgery, University Clinic Magdeburg, Germany
| | - M Fröhlich
- Clinic for General, Visceral and Vascular Surgery, University Clinic Magdeburg, Germany
| | - K Brandstädter
- Center for Pathology and Forensic Medicine, University Clinic Magdeburg, Germany
| | - C Bruns
- Clinic for General, Visceral and Vascular Surgery, University Clinic Magdeburg, Germany
| | - A Stoll
- Clinic for General, Visceral and Vascular Surgery, University Clinic Magdeburg, Germany.
| |
Collapse
|