Rohfritsch A, Barrere V, Estienne L, Melodelima D. 2D ultrasound thermometry during thermal ablation with high-intensity focused ultrasound. ULTRASONICS 2024; 142:107372. [PMID: 38850600 DOI: 10.1016/j.ultras.2024.107372] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/18/2023] [Revised: 06/02/2024] [Accepted: 06/03/2024] [Indexed: 06/10/2024]
Abstract
The clinical use of high intensity focused ultrasound (HIFU) therapy for noninvasive tissue ablation has recently gained momentum. Guidance is provided by either magnetic resonance imaging (MRI) or conventional B-mode ultrasound imaging, each with its own advantages and disadvantages. The main limitation of ultrasound imaging is its inability to provide temperature measurements over the ranges corresponding to the target temperatures during ablative thermal therapies (between 55 °C and 70 °C). Here, variations in ultrasound backscattered energy (ΔBSE) were used to monitor temperature increases in liver tissue up to an absolute value of 90 °C during and after HIFU treatment. In vitro experimental measurements were performed in 47 bovine liver samples using a toroidal HIFU transducer operating at 2.5 MHz to increase the temperature of tissues. An ultrasound imaging probe working at 7.5 MHz was placed in the center of the HIFU transducer to monitor the backscattered signals. The free-field acoustic power was set to 9 W, 12 W or 16 W in the different experiments. HIFU sonications were performed for 240 s using a duty cycle of 83 % to allow ultrasound imaging and raw radiofrequency data acquisition during exposures. Measurements showed a linear relationship between ΔBSE (in dB) and temperature (r = 0.94, p < 0.001) over a temperature range from 37 °C to 90 °C, with a high reliability of temperature measurements below 75 °C. Monitoring can be performed at the frame rate of ultrasound imaging scanners with an accuracy within an acceptable threshold of 5 °C, given the temperatures targeted during thermal ablations. If the maximum temperature reached is below 70 °C, ΔBSE is also a reliable approach for estimating the temperature during cooling. Histological analysis shown the impact of the treatment on the spatial arrangement of cells that can explain the observed variation of ΔBSE. These results demonstrate the ability of ΔBSE measurements to estimate temperature in ultrasound images within an effective therapeutic range. This method can be implemented clinically and potentially applied to other thermal-based therapies.
Collapse
Affiliation(s)
- Adrien Rohfritsch
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, F-69003, Lyon, France
| | - Victor Barrere
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, F-69003, Lyon, France
| | - Laura Estienne
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, F-69003, Lyon, France
| | - David Melodelima
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, F-69003, Lyon, France.
| |
Collapse
|
2
|
Calik J, Zawada T, Sauer N, Bove T. High Intensity Focused Ultrasound (20 MHz) and Cryotherapy as Therapeutic Options for Granuloma Annulare and Other Inflammatory Skin Conditions. Dermatol Ther (Heidelb) 2024; 14:1189-1210. [PMID: 38703308 PMCID: PMC11116313 DOI: 10.1007/s13555-024-01163-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2024] [Accepted: 04/08/2024] [Indexed: 05/06/2024] Open
Abstract
INTRODUCTION In dermatology, inflammatory skin conditions impose a substantial burden worldwide, with existing therapies showing limited efficacy and side effects. This report aims to compare a novel immunological activation induced by hyperthermic 20 MHz high intensity focused ultrasound (HIFU) with conventional cryotherapy. The bioeffects from the two methods are initially investigated by numerical models, and subsequently compared to clinical observations after treatment of a patient with the inflammatory disease granuloma annulare (GA). METHODS Clinical responses to moderate energy HIFU and cryotherapy were analysed using numerical models. HIFU-induced pressure and heat transfer were calculated, and a three-layer finite element model simulated temperature distribution and necrotic volume in the skin. Model output was compared to 22 lesions treated with HIFU and 10 with cryotherapy in a patient with GA. RESULTS Cryotherapy produced a necrotic volume of 138.5 mm3 at - 92.7 °C. HIFU at 0.3-0.6 J/exposure and focal depths of 0.8 or 1.3 mm generated necrotic volumes up to only 15.99 mm3 at temperatures of 68.3-81.2 °C. HIFU achieved full or partial resolution in all treated areas, confirming its hyperthermic immunological activation effect, while cryotherapy also resolved lesions but led to scarring and dyspigmentation. CONCLUSION Hyperthermic immunological activation of 20 MHz HIFU shows promise for treating inflammatory skin conditions as exemplified by GA. Numerical models demonstrate minimal skin necrosis compared to cryotherapy. Suggested optimal HIFU parameters are 1.3 mm focal depth, 0.4-0.5 J/exposure, 1 mm spacing, and 1 mm margin. Further studies on GA and other inflammatory diseases are recommended.
Collapse
Affiliation(s)
- Jacek Calik
- Old Town Clinic, Wszystkich Świętych 2a, 50-127, Wrocław, Poland
- Department of Clinical Oncology, Wroclaw Medical University, 50-556, Wrocław, Poland
| | - Tomasz Zawada
- TOOsonix A/S, Agern Allé 1, 2970, Hoersholm, Denmark.
| | - Natalia Sauer
- Old Town Clinic, Wszystkich Świętych 2a, 50-127, Wrocław, Poland
- Faculty of Pharmacy, Wroclaw Medical University, 50-556, Wrocław, Poland
| | - Torsten Bove
- TOOsonix A/S, Agern Allé 1, 2970, Hoersholm, Denmark
| |
Collapse
|
3
|
Martin E, Aubry JF, Schafer M, Verhagen L, Treeby B, Pauly KB. ITRUSST consensus on standardised reporting for transcranial ultrasound stimulation. Brain Stimul 2024; 17:607-615. [PMID: 38670224 DOI: 10.1016/j.brs.2024.04.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2024] [Revised: 03/30/2024] [Accepted: 04/18/2024] [Indexed: 04/28/2024] Open
Abstract
As transcranial ultrasound stimulation (TUS) advances as a precise, non-invasive neuromodulatory method, there is a need for consistent reporting standards to enable comparison and reproducibility across studies. To this end, the International Transcranial Ultrasonic Stimulation Safety and Standards Consortium (ITRUSST) formed a subcommittee of experts across several domains to review and suggest standardised reporting parameters for low intensity TUS, resulting in the guide presented here. The scope of the guide is limited to reporting the ultrasound aspects of a study. The guide and supplementary material provide a simple checklist covering the reporting of: (1) the transducer and drive system, (2) the drive system settings, (3) the free field acoustic parameters, (4) the pulse timing parameters, (5) in situ estimates of exposure parameters in the brain, and (6) intensity parameters. Detailed explanations for each of the parameters, including discussions on assumptions, measurements, and calculations, are also provided.
Collapse
Affiliation(s)
- Eleanor Martin
- Department of Medical Physics and Biomedical Engineering, University College London, London, UK; Wellcome/EPSRC Centre for Interventional and Surgical Sciences, University College London, London, UK
| | - Jean-François Aubry
- Physics for Medicine Paris, Inserm U1273, ESPCI Paris, CNRS UMR8063, PSL University, Paris, France
| | - Mark Schafer
- School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, PA, USA
| | - Lennart Verhagen
- Donders Institute for Brain, Cognition and Behaviour, Radboud University, 6525 GD Nijmegen, The Netherlands
| | - Bradley Treeby
- Department of Medical Physics and Biomedical Engineering, University College London, London, UK
| | - Kim Butts Pauly
- Department of Radiology, Stanford University, Stanford, CA, USA.
| |
Collapse
|
4
|
Cornelssen C, Finlinson E, Rolston JD, Wilcox KS. Ultrasonic therapies for seizures and drug-resistant epilepsy. Front Neurol 2023; 14:1301956. [PMID: 38162441 PMCID: PMC10756913 DOI: 10.3389/fneur.2023.1301956] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2023] [Accepted: 11/09/2023] [Indexed: 01/03/2024] Open
Abstract
Ultrasonic therapy is an increasingly promising approach for the treatment of seizures and drug-resistant epilepsy (DRE). Therapeutic focused ultrasound (FUS) uses thermal or nonthermal energy to either ablate neural tissue or modulate neural activity through high- or low-intensity FUS (HIFU, LIFU), respectively. Both HIFU and LIFU approaches have been investigated for reducing seizure activity in DRE, and additional FUS applications include disrupting the blood-brain barrier in the presence of microbubbles for targeted-drug delivery to the seizure foci. Here, we review the preclinical and clinical studies that have used FUS to treat seizures. Additionally, we review effective FUS parameters and consider limitations and future directions of FUS with respect to the treatment of DRE. While detailed studies to optimize FUS applications are ongoing, FUS has established itself as a potential noninvasive alternative for the treatment of DRE and other neurological disorders.
Collapse
Affiliation(s)
- Carena Cornelssen
- Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, United States
- Department of Pharmacology and Toxicology, University of Utah, Salt Lake City, UT, United States
| | - Eli Finlinson
- Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, United States
- Department of Pharmacology and Toxicology, University of Utah, Salt Lake City, UT, United States
| | - John D. Rolston
- Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, United States
- Department of Neurosurgery, Brigham and Women’s Hospital and Harvard Medical School, Boston, MA, United States
| | - Karen S. Wilcox
- Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, United States
- Department of Pharmacology and Toxicology, University of Utah, Salt Lake City, UT, United States
- Interdepartmental Program in Neuroscience, University of Utah, Salt Lake City, UT, United States
| |
Collapse
|
5
|
Moradi Kashkooli F, Jakhmola A, Hornsby TK, Tavakkoli JJ, Kolios MC. Ultrasound-mediated nano drug delivery for treating cancer: Fundamental physics to future directions. J Control Release 2023; 355:552-578. [PMID: 36773959 DOI: 10.1016/j.jconrel.2023.02.009] [Citation(s) in RCA: 11] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2022] [Revised: 02/03/2023] [Accepted: 02/06/2023] [Indexed: 02/13/2023]
Abstract
The application of biocompatible nanocarriers in medicine has provided several benefits over conventional treatment methods. However, achieving high treatment efficacy and deep penetration of nanocarriers in tumor tissue is still challenging. To address this, stimuli-responsive nano-sized drug delivery systems (DDSs) are an active area of investigation in delivering anticancer drugs. While ultrasound is mainly used for diagnostic purposes, it can also be applied to affect cellular function and the delivery/release of anticancer drugs. Therapeutic ultrasound (TUS) has shown potential as both a stand-alone anticancer treatment and a method to induce targeted drug release from nanocarrier systems. TUS approaches have been used to overcome various physiological obstacles, including endothelial barriers, the tumor microenvironment (TME), and immunological hurdles. Combining nanomedicine and ultrasound as a smart DDS can increase in situ drug delivery and improve access to impermeable tissues. Furthermore, smart DDSs can perform targeted drug release in response to distinctive TMEs, external triggers, or dual/multi-stimulus. This results in enhanced treatment efficacy and reduced damage to surrounding healthy tissue or organs at risk. Integrating DDSs and ultrasound is still in its early stages. More research and clinical trials are required to fully understand ultrasound's underlying physical mechanisms and interactions with various types of nanocarriers and different types of cells and tissues. In the present review, ultrasound-mediated nano-sized DDS, specifically focused on cancer treatment, is presented and discussed. Ultrasound interaction with nanoparticles (NPs), drug release mechanisms, and various types of ultrasound-sensitive NPs are examined. Additionally, in vitro, in vivo, and clinical applications of TUS are reviewed in light of the critical challenges that need to be considered to advance TUS toward an efficient, secure, straightforward, and accessible cancer treatment. This study also presents effective TUS parameters and safety considerations for this treatment modality and gives recommendations about system design and operation. Finally, future perspectives are considered, and different TUS approaches are examined and discussed in detail. This review investigates drug release and delivery through ultrasound-mediated nano-sized cancer treatment, both pre-clinically and clinically.
Collapse
Affiliation(s)
| | - Anshuman Jakhmola
- Department of Physics, Toronto Metropolitan University, Toronto, Ontario, Canada
| | - Tyler K Hornsby
- Department of Physics, Toronto Metropolitan University, Toronto, Ontario, Canada
| | - Jahangir Jahan Tavakkoli
- Department of Physics, Toronto Metropolitan University, Toronto, Ontario, Canada; Institute for Biomedical Engineering, Science and Technology (iBEST), Keenan Research Centre for Biomedical Science, St. Michael's Hospital, Toronto, Ontario, Canada
| | - Michael C Kolios
- Department of Physics, Toronto Metropolitan University, Toronto, Ontario, Canada; Institute for Biomedical Engineering, Science and Technology (iBEST), Keenan Research Centre for Biomedical Science, St. Michael's Hospital, Toronto, Ontario, Canada.
| |
Collapse
|
6
|
Harris GR, Howard SM, Hurrell AM, Lewin PA, Schafer ME, Wear KA, Wilkens V, Zeqiri B. Hydrophone Measurements for Biomedical Ultrasound Applications: A Review. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2023; 70:85-100. [PMID: 36215339 PMCID: PMC10079648 DOI: 10.1109/tuffc.2022.3213185] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
This article presents basic principles of hydrophone measurements, including mechanisms of action for various hydrophone designs, sensitivity and directivity calibration procedures, practical considerations for performing measurements, signal processing methods to correct for both frequency-dependent sensitivity and spatial averaging across the hydrophone sensitive element, uncertainty in hydrophone measurements, special considerations for high-intensity therapeutic ultrasound, and advice for choosing an appropriate hydrophone for a particular measurement task. Recommendations are made for information to be included in hydrophone measurement reporting.
Collapse
|
7
|
Li L, Zhang X, Zhou J, Zhang L, Xue J, Tao W. Non-Invasive Thermal Therapy for Tissue Engineering and Regenerative Medicine. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2022; 18:e2107705. [PMID: 35475541 DOI: 10.1002/smll.202107705] [Citation(s) in RCA: 26] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/12/2021] [Revised: 03/11/2022] [Indexed: 06/14/2023]
Abstract
Owing to the development of nanotechnology and noninvasive treatment, thermal therapy in combination with external stimuli has been applied for tissue engineering and regenerative medicine (TERM), which has attracted more and more attention in recent years. In this review, the recent progress of applying a variety of non-invasive thermal therapeutic modalities for TERM, including photothermal therapy, magnetic thermotherapy, and ultrasound thermotherapy, as well as other thermal therapeutics are discussed. The parameters and conditions that need to be considered and regulated to realize a well-controlled thermal therapy for tissue regeneration are also discussed. Afterwards, the current concerns and challenges of putting thermal therapy into clinical applications are pointed out. At last, perspectives are provided for the future development directions, aiming to providing opportunities and a novel pathway for TERM.
Collapse
Affiliation(s)
- Longfei Li
- Beijing Laboratory of Biomedical Materials, Beijing University of Chemical Technology, Beijing, 100029, P. R. China
- State Key Laboratory of Organic-Inorganic Composites, Beijing University of Chemical Technology, Beijing, 100029, P. R. China
| | - Xiaodi Zhang
- Beijing Laboratory of Biomedical Materials, Beijing University of Chemical Technology, Beijing, 100029, P. R. China
- State Key Laboratory of Organic-Inorganic Composites, Beijing University of Chemical Technology, Beijing, 100029, P. R. China
- Center for Nanomedicine and Department of Anesthesiology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, 02115, United States
| | - Jun Zhou
- Center for Nanomedicine and Department of Anesthesiology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, 02115, United States
| | - Liqun Zhang
- Beijing Laboratory of Biomedical Materials, Beijing University of Chemical Technology, Beijing, 100029, P. R. China
- State Key Laboratory of Organic-Inorganic Composites, Beijing University of Chemical Technology, Beijing, 100029, P. R. China
| | - Jiajia Xue
- Beijing Laboratory of Biomedical Materials, Beijing University of Chemical Technology, Beijing, 100029, P. R. China
- State Key Laboratory of Organic-Inorganic Composites, Beijing University of Chemical Technology, Beijing, 100029, P. R. China
| | - Wei Tao
- Center for Nanomedicine and Department of Anesthesiology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, 02115, United States
| |
Collapse
|
8
|
Payne A, Chopra R, Ellens N, Chen L, Ghanouni P, Sammet S, Diederich C, Ter Haar G, Parker D, Moonen C, Stafford J, Moros E, Schlesinger D, Benedict S, Wear K, Partanen A, Farahani K. AAPM Task Group 241: A medical physicist's guide to MRI-guided focused ultrasound body systems. Med Phys 2021; 48:e772-e806. [PMID: 34224149 DOI: 10.1002/mp.15076] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2020] [Revised: 04/28/2021] [Accepted: 06/21/2021] [Indexed: 11/07/2022] Open
Abstract
Magnetic resonance-guided focused ultrasound (MRgFUS) is a completely non-invasive technology that has been approved by FDA to treat several diseases. This report, prepared by the American Association of Physicist in Medicine (AAPM) Task Group 241, provides background on MRgFUS technology with a focus on clinical body MRgFUS systems. The report addresses the issues of interest to the medical physics community, specific to the body MRgFUS system configuration, and provides recommendations on how to successfully implement and maintain a clinical MRgFUS program. The following sections describe the key features of typical MRgFUS systems and clinical workflow and provide key points and best practices for the medical physicist. Commonly used terms, metrics and physics are defined and sources of uncertainty that affect MRgFUS procedures are described. Finally, safety and quality assurance procedures are explained, the recommended role of the medical physicist in MRgFUS procedures is described, and regulatory requirements for planning clinical trials are detailed. Although this report is limited in scope to clinical body MRgFUS systems that are approved or currently undergoing clinical trials in the United States, much of the material presented is also applicable to systems designed for other applications.
Collapse
Affiliation(s)
- Allison Payne
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, UT, USA
| | - Rajiv Chopra
- Department of Radiology, UT Southwestern Medical Center, Dallas, TX, USA
| | | | - Lili Chen
- Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA, USA
| | - Pejman Ghanouni
- Department of Radiology, Stanford University, Stanford, CA, USA
| | - Steffen Sammet
- Department of Radiology, University of Chicago, Chicago, IL, USA
| | - Chris Diederich
- Department of Radiation Oncology, University of California San Francisco, San Francisco, CA, USA
| | | | - Dennis Parker
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, UT, USA
| | - Chrit Moonen
- Imaging Division, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Jason Stafford
- Department of Imaging Physics, MD Anderson Cancer Center, Houston, TX, USA
| | - Eduardo Moros
- Department of Radiation Oncology, Moffitt Cancer Center, Tampa, FL, USA
| | - David Schlesinger
- Department of Radiation Oncology, University of Virginia, Charlottesville, VA, USA
| | | | - Keith Wear
- U.S. Food and Drug Administration, Silver Spring, MD, USA
| | | | - Keyvan Farahani
- National Cancer Institute, National Institutes of Health, Rockville, MD, USA
| |
Collapse
|
9
|
Snehota M, Vachutka J, Ter Haar G, Dolezal L, Kolarova H. Therapeutic ultrasound experiments in vitro: Review of factors influencing outcomes and reproducibility. ULTRASONICS 2020; 107:106167. [PMID: 32402858 DOI: 10.1016/j.ultras.2020.106167] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/06/2019] [Revised: 04/16/2020] [Accepted: 04/23/2020] [Indexed: 05/07/2023]
Abstract
Current in vitro sonication experiments show immense variability in experimental set-ups and methods used. As a result, there is uncertainty in the ultrasound field parameters experienced by sonicated samples, poor reproducibility of these experiments and thus reduced scientific value of the results obtained. The scope of this narrative review is to briefly describe mechanisms of action of ultrasound, list the most frequently used experimental set-ups and focus on a description of factors influencing the outcomes and reproducibility of these experiments. The factors assessed include: proper reporting of ultrasound exposure parameters, experimental geometry, coupling medium quality, influence of culture vessels, formation of standing waves, motion/rotation of the sonicated sample and the characteristics of the sample itself. In the discussion we describe pros and cons of particular exposure geometries and factors, and make a few recommendations as to how to increase the reproducibility and validity of the experiments performed.
Collapse
Affiliation(s)
- Martin Snehota
- Department of Medical Biophysics, Faculty of Medicine and Dentistry, Palacky University Olomouc, Hnevotinska 3, Olomouc 775 15, Czech Republic; Institute of Molecular and Translational Medicine, Faculty of Medicine and Dentistry, Palacky University Olomouc, Hnevotinska 5, Olomouc 779 00, Czech Republic
| | - Jaromir Vachutka
- Department of Medical Biophysics, Faculty of Medicine and Dentistry, Palacky University Olomouc, Hnevotinska 3, Olomouc 775 15, Czech Republic.
| | - Gail Ter Haar
- Joint Department of Physics and Cancer Research UK Cancer Imaging Centre, Division of Radiotherapy and Imaging, The Institute of Cancer Research, London and The Royal Marsden NHS Foundation Trust, Sutton, London SM2 5PT, United Kingdom
| | - Ladislav Dolezal
- Department of Medical Biophysics, Faculty of Medicine and Dentistry, Palacky University Olomouc, Hnevotinska 3, Olomouc 775 15, Czech Republic
| | - Hana Kolarova
- Department of Medical Biophysics, Faculty of Medicine and Dentistry, Palacky University Olomouc, Hnevotinska 3, Olomouc 775 15, Czech Republic; Institute of Molecular and Translational Medicine, Faculty of Medicine and Dentistry, Palacky University Olomouc, Hnevotinska 5, Olomouc 779 00, Czech Republic
| |
Collapse
|
10
|
Legon W, Adams S, Bansal P, Patel PD, Hobbs L, Ai L, Mueller JK, Meekins G, Gillick BT. A retrospective qualitative report of symptoms and safety from transcranial focused ultrasound for neuromodulation in humans. Sci Rep 2020; 10:5573. [PMID: 32221350 PMCID: PMC7101402 DOI: 10.1038/s41598-020-62265-8] [Citation(s) in RCA: 47] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2019] [Accepted: 03/04/2020] [Indexed: 02/08/2023] Open
Abstract
Low intensity transcranial focused ultrasound (LIFU) is a promising method of non-invasive neuromodulation that uses mechanical energy to affect neuronal excitability. LIFU confers high spatial resolution and adjustable focal lengths for precise neuromodulation of discrete regions in the human brain. Before the full potential of low intensity ultrasound for research and clinical application can be investigated, data on the safety of this technique is indicated. Here, we provide an evaluation of the safety of LIFU for human neuromodulation through participant report and neurological assessment with a comparison of symptomology to other forms of non-invasive brain stimulation. Participants (N = 120) that were enrolled in one of seven human ultrasound neuromodulation studies in one laboratory at the University of Minnesota (2015–2017) were queried to complete a follow-up Participant Report of Symptoms questionnaire assessing their self-reported experience and tolerance to participation in LIFU research (Isppa 11.56–17.12 W/cm2) and the perceived relation of symptoms to LIFU. A total of 64/120 participant (53%) responded to follow-up requests to complete the Participant Report of Symptoms questionnaire. None of the participants experienced serious adverse effects. From the post-hoc assessment of safety using the questionnaire, 7/64 reported mild to moderate symptoms, that were perceived as ‘possibly’ or ‘probably’ related to participation in LIFU experiments. These reports included neck pain, problems with attention, muscle twitches and anxiety. The most common unrelated symptoms included sleepiness and neck pain. There were initial transient reports of mild neck pain, scalp tingling and headache that were extinguished upon follow-up. No new symptoms were reported upon follow up out to 1 month. The profile and incidence of symptoms looks to be similar to other forms of non-invasive brain stimulation.
Collapse
Affiliation(s)
- Wynn Legon
- Division of Physical Therapy and Rehabilitation Science, Department of Rehabilitation Medicine, School of Medicine, University of Minnesota, MN, Minneapolis, USA. .,Department of Neurological Surgery, School of Medicine, University of Virginia, VA, Charlottesville, USA.
| | - Sarah Adams
- Department of Neurological Surgery, School of Medicine, University of Virginia, VA, Charlottesville, USA
| | - Priya Bansal
- Division of Physical Therapy and Rehabilitation Science, Department of Rehabilitation Medicine, School of Medicine, University of Minnesota, MN, Minneapolis, USA
| | - Parantap D Patel
- School of Medicine, University of Virginia, VA, Charlottesville, USA
| | - Landon Hobbs
- School of Medicine, University of Virginia, VA, Charlottesville, USA
| | - Leo Ai
- Division of Physical Therapy and Rehabilitation Science, Department of Rehabilitation Medicine, School of Medicine, University of Minnesota, MN, Minneapolis, USA
| | - Jerel K Mueller
- Division of Physical Therapy and Rehabilitation Science, Department of Rehabilitation Medicine, School of Medicine, University of Minnesota, MN, Minneapolis, USA
| | - Gregg Meekins
- Department of Neurology, School of Medicine, University of Minnesota, MN, Minneapolis, USA
| | - Bernadette T Gillick
- Division of Physical Therapy and Rehabilitation Science, Department of Rehabilitation Medicine, School of Medicine, University of Minnesota, MN, Minneapolis, USA
| |
Collapse
|
11
|
Wear KA, Howard SM. Correction for Spatial Averaging Artifacts in Hydrophone Measurements of High-Intensity Therapeutic Ultrasound: An Inverse Filter Approach. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2019; 66:1453-1464. [PMID: 31247548 PMCID: PMC6936621 DOI: 10.1109/tuffc.2019.2924351] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
High-intensity therapeutic ultrasound (HITU) pressure is often measured using a hydrophone. HITU pressure waves typically contain multiple harmonics due to nonlinear propagation. As harmonic frequency increases, harmonic beamwidth decreases. For sufficiently high harmonic frequency, beamwidth may become comparable to the hydrophone effective sensitive element diameter, resulting in signal reduction due to spatial averaging. An analytic formula for a hydrophone spatial averaging filter for beams with Gaussian harmonic radial profiles was tested on HITU pressure signals generated by three transducers (1.45 MHz, F/1; 1.53 MHz, F/1.5; 3.91 MHz, F/1) with focal pressures up to 48 MPa. The HITU signals were measured using fiber-optic and needle hydrophones (nominal geometrical sensitive element diameters: 100 and [Formula: see text]). Harmonic radial profiles were measured with transverse scans in the focal plane using the fiber-optic hydrophone. Harmonic radial profiles were accurately approximated by Gaussian functions with root-mean-square (rms) differences between transverse scans and Gaussian fits less than 9% for frequencies up to approximately 50 MHz. The Gaussian harmonic beamwidth parameter σn varied with harmonic number n according to a power law, σn = σ1/nq where . RMS differences between experimental and theoretical spatial averaging filters were 11% ± 1% (1.45 MHz), 8% ± 1% (1.53 MHz), and 4% ± 1% (3.91 MHz). For the two more highly focused (F/1) transducers, the effect of spatial averaging was to underestimate peak compressional pressure (pcp), peak rarefactional pressure (prp), and pulse intensity integral (pii) by (mean ± standard deviation) (pcp: 4.9% ± 0.5%, prp: 0.4% ± 0.2%, pii: 2.9% ± 1%) and (pcp: 28.3% ± 9.6%, prp: 6% ± 2.4%, pii: 24.3% ± 6.7%) for the 100- and 400- [Formula: see text]-diameter hydrophones, respectively. These errors can be suppressed by the application of the inverse spatial averaging filter.
Collapse
|
12
|
Beisenova A, Issatayeva A, Sovetov S, Korganbayev S, Jelbuldina M, Ashikbayeva Z, Blanc W, Schena E, Sales S, Molardi C, Tosi D. Multi-fiber distributed thermal profiling of minimally invasive thermal ablation with scattering-level multiplexing in MgO-doped fibers. BIOMEDICAL OPTICS EXPRESS 2019; 10:1282-1296. [PMID: 30891346 PMCID: PMC6420269 DOI: 10.1364/boe.10.001282] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/27/2018] [Revised: 01/10/2019] [Accepted: 01/14/2019] [Indexed: 05/03/2023]
Abstract
We propose a setup for multiplexed distributed optical fiber sensors capable of resolving temperature distribution in thermo-therapies, with a spatial resolution of 2.5 mm over multiple fibers interrogated simultaneously. The setup is based on optical backscatter reflectometry (OBR) applied to optical fibers having backscattered power significantly larger than standard fibers (36.5 dB), obtained through MgO doping. The setup is based on a scattering-level multiplexing, which allows interrogating all the sensing fibers simultaneously, thanks to the fact that the backscattered power can be unambiguously associated to each fiber. The setup has been validated for the planar measurement of temperature profiles in ex vivo radiofrequency ablation, obtaining the measurement of temperature over a surface of 96 total points (4 fibers, 8 sensing points per cm2). The spatial resolution obtained for the planar measurement allows extending distributed sensing to surface, or even three-dimensional, geometries performing temperature sensing in the tissue with millimeter resolution in multiple dimensions.
Collapse
Affiliation(s)
- Aidana Beisenova
- Nazarbayev University, Department of Electrical and Computer Engineering, 010000 Astana, Kazakhstan
| | - Aizhan Issatayeva
- Nazarbayev University, Department of Electrical and Computer Engineering, 010000 Astana, Kazakhstan
| | - Sultan Sovetov
- Nazarbayev University, Department of Electrical and Computer Engineering, 010000 Astana, Kazakhstan
| | - Sanzhar Korganbayev
- Laboratory of Biosensors and Bioinstruments, National Laboratory Astana, 010000 Astana, Kazakhstan
| | - Madina Jelbuldina
- Nazarbayev University, Department of Electrical and Computer Engineering, 010000 Astana, Kazakhstan
- Laboratory of Biosensors and Bioinstruments, National Laboratory Astana, 010000 Astana, Kazakhstan
| | - Zhannat Ashikbayeva
- Nazarbayev University, Department of Electrical and Computer Engineering, 010000 Astana, Kazakhstan
- Laboratory of Biosensors and Bioinstruments, National Laboratory Astana, 010000 Astana, Kazakhstan
| | - Wilfried Blanc
- Université Côte d’Azur, INPHYNI–CNRS UMR 7010, Parc Valrose, 06108 Nice, France
| | - Emiliano Schena
- E. Unit of Measurements and Biomedical Instrumentation, University Campus Bio-Medico of Rome, via Alvaro del Portillo 21, 00128 Rome, Italy
| | - Salvador Sales
- Institute of Telecommunications and Multimedia Applications (iTEAM), Universitat Politècnica de València, Camino de Vera s/n, 46022 Valencia, Spain
| | - Carlo Molardi
- Nazarbayev University, Department of Electrical and Computer Engineering, 010000 Astana, Kazakhstan
| | - Daniele Tosi
- Nazarbayev University, Department of Electrical and Computer Engineering, 010000 Astana, Kazakhstan
- Laboratory of Biosensors and Bioinstruments, National Laboratory Astana, 010000 Astana, Kazakhstan
| |
Collapse
|
13
|
Mouratidis PXE, Rivens I, Civale J, Symonds-Tayler R, Ter Haar G. 'Relationship between thermal dose and cell death for "rapid" ablative and "slow" hyperthermic heating'. Int J Hyperthermia 2019; 36:229-243. [PMID: 30700171 DOI: 10.1080/02656736.2018.1558289] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2018] [Revised: 11/30/2018] [Accepted: 12/05/2018] [Indexed: 02/07/2023] Open
Abstract
AIM Thermal isoeffective dose (TID) has not been convincingly validated for application to predict biological effects from rapid thermal ablation (e.g., using >55 °C). This study compares the classical method of quantifying TID (derived from hyperthermia data) with a temperature-adjusted method based on the Arrhenius model for predicting cell survival in vitro, after either 'rapid' ablative or 'slow' hyperthermic exposures. METHODS MTT assay viability data was obtained from two human colon cancer cell lines, (HCT116, HT29), subjected to a range of TIDs (120-720 CEM43) using a thermal cycler for hyperthermic (>2 minutes, <50 °C) treatments, or a novel pre-heated water bath based technique for ablative exposures (<10 seconds, >55 °C). TID was initially estimated using a constant RCEM>43°C=0.5, and subsequently using RCEM(T), derived from temperature dependent cell survival (injury rate) Arrhenius analysis. RESULTS 'Slow' and 'rapid' exposures resulted in cell survival and significant regrowth (both cell lines) 10 days post-treatment for 240 CEM43 (RCEM>43°C=0.5), while 340-550 CEM43 (RCEM>43°C =0.5) delivered using 'rapid' exposures showed 12 ± 6% viability and 'slow' exposures resulted in undetectable viability. Arrhenius analysis of experimental data (activation energy ΔE = 5.78 ± 0.04 × 105 J mole-1, frequency factor A = 3.27 ± 11 × 1091 sec-1) yielded RCEM=0.42 * e0.0041*T which better-predicted cell survival than using R CEM> 43°C=0.5. CONCLUSIONS TID calculated using an RCEM(T) informed by Arrhenius kinetic parameters provided a more consistent, heating strategy independent, predictor of cell viability, improving dosimetry of ablative thermal exposures. Cell viability was only undetectable above 305 ± 10 CEM43 using this revised measure.
Collapse
Affiliation(s)
- Petros X E Mouratidis
- a Joint Department of Physics, Division of Radiotherapy and Imaging , The Institute of Cancer Research: Royal Marsden Hospital , Sutton , UK
| | - Ian Rivens
- a Joint Department of Physics, Division of Radiotherapy and Imaging , The Institute of Cancer Research: Royal Marsden Hospital , Sutton , UK
| | - John Civale
- a Joint Department of Physics, Division of Radiotherapy and Imaging , The Institute of Cancer Research: Royal Marsden Hospital , Sutton , UK
| | - Richard Symonds-Tayler
- a Joint Department of Physics, Division of Radiotherapy and Imaging , The Institute of Cancer Research: Royal Marsden Hospital , Sutton , UK
| | - Gail Ter Haar
- a Joint Department of Physics, Division of Radiotherapy and Imaging , The Institute of Cancer Research: Royal Marsden Hospital , Sutton , UK
| |
Collapse
|
14
|
Liu Y, Chen X, Guo A, Liu S, Hu G. Quantitative Assessments of Mechanical Responses upon Radial Extracorporeal Shock Wave Therapy. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2018; 5:1700797. [PMID: 29593978 PMCID: PMC5867036 DOI: 10.1002/advs.201700797] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/30/2017] [Indexed: 05/03/2023]
Abstract
Although radial extracorporeal shock wave therapy (rESWT) has been widely used to treat orthopedic disorders with promising clinical results, rESWT largely relies on clinicians' personal experiences and arbitrary judgments, without knowing relationships between administration doses and effective doses at target sites. In fact, practitioners lack a general and reliable way to assess propagation and distribution of pressure waves inside biological tissues quantitatively. This study develops a methodology to combine experimental measurements and computational simulations to obtain pressure fields from rESWT through calibrating and validating computational models with experimental measurements. Wave pressures at the bottom of a petri dish and inside biological tissues are measured, respectively, by attaching and implanting flexible membrane sensors. Detailed wave dynamics are simulated through explicit finite element analyses. The data decipher that waves from rESWT radiate directionally and can be modeled as acoustic waves generated from a vibrating circular piston. Models are thus established to correlate pressure amplitudes at the bottom of petri dishes and in the axial direction of biological tissues. Additionally, a pilot simulation upon rESWT for human lumbar reveals a detailed and realistic pressure field mapping. This study will open a new avenue of personalized treatment planning and mechanism research for rESWT.
Collapse
Affiliation(s)
- Yajun Liu
- Orthopedic Shock Wave Treatment CenterSpine Surgery DepartmentBeijing Jishuitan HospitalBeijing100035China
| | - Xiaodong Chen
- The State Key Laboratory of Nonlinear MechanicsBeijing Key Laboratory of Engineered Construction and MechanobiologyInstitute of MechanicsChinese Academy of SciencesBeijing100190China
- School of Engineering ScienceUniversity of Chinese Academy of SciencesBeijing100049China
| | - Anyi Guo
- Orthopedic Shock Wave Treatment CenterSpine Surgery DepartmentBeijing Jishuitan HospitalBeijing100035China
| | - Sijin Liu
- The State Key Laboratory of Environmental Chemistry and EcotoxicologyResearch Center for Eco‐Environmental SciencesChinese Academy of SciencesBeijing100085China
| | - Guoqing Hu
- The State Key Laboratory of Nonlinear MechanicsBeijing Key Laboratory of Engineered Construction and MechanobiologyInstitute of MechanicsChinese Academy of SciencesBeijing100190China
- School of Engineering ScienceUniversity of Chinese Academy of SciencesBeijing100049China
| |
Collapse
|
15
|
Haller J, Wilkens V. Determination of Acoustic Cavitation Probabilities and Thresholds Using a Single Focusing Transducer to Induce and Detect Acoustic Cavitation Events: II. Systematic Investigation in an Agar Material. ULTRASOUND IN MEDICINE & BIOLOGY 2018; 44:397-415. [PMID: 29195755 DOI: 10.1016/j.ultrasmedbio.2017.10.007] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/05/2016] [Revised: 10/04/2017] [Accepted: 10/12/2017] [Indexed: 05/05/2023]
Abstract
In the accompanying article (Part I), a method is described to determine acoustic cavitation probabilities in tissue-mimicking materials (TMMs) using a high-intensity focused ultrasound (HIFU) transducer for both inducing and detecting the acoustic cavitation events, and its suitability for different sonication modes like continuous wave, single pulses (with pulse lengths from microseconds to milliseconds) and repeated burst signals is discussed. In Part II, the use of the method for a systematic study of the dependence of the acoustic cavitation thresholds in 3% (by weight) agar phantoms on the temporal sonication parameters is discussed. The values obtained at a frequency of 1.06 MHz, ranging from (0.58 ± 0.12) MPa for a 3-s continuous wave mode sonication to (5.2 ± 1.0) MPa for single shots with a length of 10 wave cycles, are discussed and interpreted on the basis of literature values and their self-consistency.
Collapse
Affiliation(s)
- Julian Haller
- Physikalisch-Technische Bundesanstalt, Braunschweig, Germany
| | - Volker Wilkens
- Physikalisch-Technische Bundesanstalt, Braunschweig, Germany.
| |
Collapse
|
16
|
Alvarenga AV, Wilkens V, Georg O, Costa-Félix RPB. Non-invasive Estimation of Temperature during Physiotherapeutic Ultrasound Application Using the Average Gray-Level Content of B-Mode Images: A Metrological Approach. ULTRASOUND IN MEDICINE & BIOLOGY 2017; 43:1938-1952. [PMID: 28619277 DOI: 10.1016/j.ultrasmedbio.2017.04.008] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/10/2016] [Revised: 03/03/2017] [Accepted: 04/09/2017] [Indexed: 06/07/2023]
Abstract
Healing therapies that make use of ultrasound are based on raising the temperature in biological tissue. However, it is not possible to heal impaired tissue by applying a high dose of ultrasound. The temperature of the tissue is ultimately the physical quantity that has to be assessed to minimize the risk of undesired injury. Invasive temperature measurement techniques are easy to use, despite the fact that they are detrimental to human well being. Another approach to assessing a rise in tissue temperature is to derive the material's general response to temperature variations from ultrasonic parameters. In this article, a method for evaluating temperature variations is described. The method is based on the analytical study of an ultrasonic image, in which gray-level variations are correlated to the temperature variations in a tissue-mimicking material. The physical assumption is that temperature variations induce wave propagation changes modifying the backscattered ultrasound signal, which are expressed in the ultrasonographic images. For a temperature variation of about 15°C, the expanded uncertainty for a coverage probability of 0.95 was found to be 2.5°C in the heating regime and 1.9°C in the cooling regime. It is possible to use the model proposed in this article in a straightforward manner to monitor temperature variation during a physiotherapeutic ultrasound application, provided the tissue-mimicking material approach is transferred to actual biological tissue. The novelty of such approach resides in the metrology-based investigation outlined here, as well as in its ease of reproducibility.
Collapse
Affiliation(s)
- André V Alvarenga
- Laboratory of Ultrasound, Directory of Scientific and Industrial Metrology (DIMCI), National Institute of Metrology, Quality and Technology (INMETRO), Rio de Janeiro, Brazil.
| | - Volker Wilkens
- Physikalisch-Technische Bundesanstalt, Braunschweig, Germany
| | - Olga Georg
- Physikalisch-Technische Bundesanstalt, Braunschweig, Germany
| | - Rodrigo P B Costa-Félix
- Laboratory of Ultrasound, Directory of Scientific and Industrial Metrology (DIMCI), National Institute of Metrology, Quality and Technology (INMETRO), Rio de Janeiro, Brazil
| |
Collapse
|
17
|
Landa FJO, Deán-Ben XL, Sroka R, Razansky D. Volumetric Optoacoustic Temperature Mapping in Photothermal Therapy. Sci Rep 2017; 7:9695. [PMID: 28851968 PMCID: PMC5575057 DOI: 10.1038/s41598-017-09069-5] [Citation(s) in RCA: 43] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2017] [Accepted: 07/21/2017] [Indexed: 12/27/2022] Open
Abstract
Photothermal therapy and ablation are commonplace medical procedures employed for treatment of tumors, vascular and brain abnormalities as well as other disorders that require selective destruction of tissues. Yet, accurate mapping of the dynamic temperature field distribution in the treated region represents an unmet clinical need, strongly affecting the clinical outcome of these interventions. We introduce a fast three-dimensional temperature mapping method based on real-time optoacoustic sensing of the treated region coupled with a thermal-diffusion-based model of heat distribution in tissues. Deviations of the optoacoustic temperature readings provided at 40 ms intervals remained below 10% in tissue-mimicking phantom experiments for temperature elevations above 3 °C, as validated by simultaneous thermocouple measurements. Performance of the new method to dynamically estimate the volumetric temperature distribution was further showcased in post-mortem mouse imaging experiments. The newly discovered capacity to non-invasively measure the temperature map in an entire treated volume with both high spatial and temporal resolutions holds potential for improving safety and efficacy of light-based therapeutic interventions.
Collapse
Affiliation(s)
- Francisco Javier Oyaga Landa
- Institute for Biological and Medical Imaging (IBMI), Helmholtz Center Munich, Neuherberg, Germany
- Faculty of Medicine, Technical University of Munich, Munich, Germany
| | - Xosé Luís Deán-Ben
- Institute for Biological and Medical Imaging (IBMI), Helmholtz Center Munich, Neuherberg, Germany
| | - Ronald Sroka
- Laser Research Laboratory/LIFE Center, Ludwig-Maximilian-University, Munich, Germany
| | - Daniel Razansky
- Institute for Biological and Medical Imaging (IBMI), Helmholtz Center Munich, Neuherberg, Germany.
- Faculty of Medicine, Technical University of Munich, Munich, Germany.
| |
Collapse
|
18
|
Salgarella AR, Cafarelli A, Ricotti L, Capineri L, Dario P, Menciassi A. Optimal Ultrasound Exposure Conditions for Maximizing C2C12 Muscle Cell Proliferation and Differentiation. ULTRASOUND IN MEDICINE & BIOLOGY 2017; 43:1452-1465. [PMID: 28433437 DOI: 10.1016/j.ultrasmedbio.2017.03.003] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/15/2016] [Revised: 02/27/2017] [Accepted: 03/06/2017] [Indexed: 05/07/2023]
Abstract
Described here is an in vitro systematic investigation of the effects on C2C12 myoblasts of exposure to finely controlled and repeatable low-intensity pulsed ultrasound of different frequencies (500 kHz, 1 MHz, 3 MHz and 5 MHz) and different intensities (250, 500 and 1000 mW/cm2). An in-house stimulation system and an ultrasound-transparent cell culture well minimized reflections and attenuations, allowing precise control of ultrasound delivery. Results indicated that a 3 MHz stimulation at 1 W/cm2 intensity maximized cell proliferation in comparison with the other exposure conditions and untreated controls. In contrast, cell differentiation and the consequent formation of multinucleated myotubes were maximized by 1 MHz stimulation at 500 mW/cm2 intensity. The highly controlled exposure conditions employed allowed precise correlation of the ultrasound delivery to the bio-effects produced, thus overcoming the inconsistency of some results available in the literature and contributing to the potential of ultrasound treatment for muscle therapy and regeneration.
Collapse
Affiliation(s)
| | - Andrea Cafarelli
- The BioRobotics Institute, Scuola Superiore Sant'Anna, Pontedera (Pisa), Italy
| | - Leonardo Ricotti
- The BioRobotics Institute, Scuola Superiore Sant'Anna, Pontedera (Pisa), Italy
| | - Lorenzo Capineri
- Department of Information Engineering, University of Florence, Florence, Italy
| | - Paolo Dario
- The BioRobotics Institute, Scuola Superiore Sant'Anna, Pontedera (Pisa), Italy
| | - Arianna Menciassi
- The BioRobotics Institute, Scuola Superiore Sant'Anna, Pontedera (Pisa), Italy
| |
Collapse
|
19
|
Thermal and mechanical high-intensity focused ultrasound: perspectives on tumor ablation, immune effects and combination strategies. Cancer Immunol Immunother 2016; 66:247-258. [PMID: 27585790 PMCID: PMC5281669 DOI: 10.1007/s00262-016-1891-9] [Citation(s) in RCA: 158] [Impact Index Per Article: 19.8] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2016] [Accepted: 08/18/2016] [Indexed: 12/21/2022]
Abstract
Tumor ablation technologies, such as radiofrequency-, cryo- or high-intensity focused ultrasound (HIFU) ablation will destroy tumor tissue in a minimally invasive manner. Ablation generates large volumes of tumor debris in situ, releasing multiple bio-molecules like tumor antigens and damage-associated molecular patterns. To initiate an adaptive antitumor immune response, antigen-presenting cells need to take up tumor antigens and, following activation, present them to immune effector cells. The impact of the type of tumor ablation on the precise nature, availability and suitability of the tumor debris for immune response induction, however, is poorly understood. In this review, we focus on immune effects after HIFU-mediated ablation and compare these to findings using other ablation technologies. HIFU can be used both for thermal and mechanical destruction of tissue, inducing coagulative necrosis or subcellular fragmentation, respectively. Preclinical and clinical results of HIFU tumor ablation show increased infiltration and activation of CD4+ and CD8+ T cells. As previously observed for other types of tumor ablation technologies, however, this ablation-induced enhanced infiltration alone appears insufficient to generate consistent protective antitumor immunity. Therapies combining ablation with immune stimulation are therefore expected to be key to boost HIFU-induced immune effects and to achieve systemic, long-lasting, antitumor immunity.
Collapse
|
20
|
Grisey A, Yon S, Letort V, Lafitte P. Simulation of high-intensity focused ultrasound lesions in presence of boiling. J Ther Ultrasound 2016; 4:11. [PMID: 27034778 PMCID: PMC4815116 DOI: 10.1186/s40349-016-0056-9] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2015] [Accepted: 03/17/2016] [Indexed: 01/18/2023] Open
Abstract
Background The lesions induced by high-intensity focused ultrasound (HIFU) thermal ablations are particularly difficult to simulate due to the complexity of the involved phenomena. In particular, boiling has a strong influence on the lesion shape. Thus, it must be accounted for if it happens during the pulses to be modeled. However, no acoustic model enables the simulation of the resulting wave scattering. Therefore, we propose an equivalent model for the heat deposition pattern in the presence of boiling. Methods Firstly, the acoustic field is simulated with k-Wave and the heat source term is calculated. Then, a thermal model is designed, including the equivalent model for boiling. It is rigorously calibrated and validated through the use of diversified ex vivo and in vivo data, including usually unexploited data types related to the bubble clouds. Results The proposed model enabled to efficiently simulate unitary pulses properties, including the sizes of the lesions, their morphology, the boiling onset time, and the influence of the boiling onset time on the lesions sizes. Conclusions In this article, the whole procedure of model design, calibration, and validation is discussed. In addition to depicting the creative use of data, our modeling approach focuses on the understanding of the mechanisms influencing the shape of the lesion. Further work is required to study the influence of the remaining bubble clouds in the context of pulse groups.
Collapse
Affiliation(s)
- Anthony Grisey
- Theraclion, 102 Rue Etienne Dolet, Malakoff, 92240 France ; CentraleSupélec, Mathematics in Interaction with Computer Science, Grande voie des vignes, Châtenay-Malabry, 92295 France
| | - Sylvain Yon
- Theraclion, 102 Rue Etienne Dolet, Malakoff, 92240 France
| | - Véronique Letort
- CentraleSupélec, Mathematics in Interaction with Computer Science, Grande voie des vignes, Châtenay-Malabry, 92295 France
| | - Pauline Lafitte
- CentraleSupélec, Mathematics in Interaction with Computer Science, Grande voie des vignes, Châtenay-Malabry, 92295 France
| |
Collapse
|
21
|
Shaw A, Martin E, Haller J, ter Haar G. Equipment, measurement and dose-a survey for therapeutic ultrasound. J Ther Ultrasound 2016; 4:7. [PMID: 26941956 PMCID: PMC4776354 DOI: 10.1186/s40349-016-0051-1] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2015] [Accepted: 02/19/2016] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Dosimetry for Ultrasound Therapy (DUTy) is a large international project which addresses the development of a metrological infrastructure for the determination of ultrasound exposure and dose to tissue. METHODS In order to seek the views of the wider therapy ultrasound community and to review dose and in situ exposure quantities that have been suggested or used previously, a web-based questionnaire containing a range of questions covering the type of ultrasound equipment that is used and the range of applications for which it has been developed was created at www.surveymonkey.com. This questionnaire was intended to cover any contemporary therapeutic ultrasound application (including physiotherapy, lithotripsy and drug delivery) and asked specific questions about quantification of in situ exposure and dose, especially as relevant to treatment planning, standardisation and/or regulation. RESULTS This paper summarises the 123 responses submitted between February and September 2014 to the questions on clinical applications, equipment, quality assurance (QA) and measurement and standards, as well as to those relating to an understanding of "dose" in the context of ultrasound. The full set of anonymous responses is available in an additional Excel file. CONCLUSIONS The results clearly demonstrate the need not only for further improvements in measuring devices and for measurement guidelines but also for a wider dissemination and higher awareness of existing standards. Whilst it is unlikely that a single definition of dose can be sufficient for all ultrasound treatment modalities, the answers clearly indicate that many aspects would benefit from clear definitions of relevant dose quantities and shed light on the preferred form of such definitions.
Collapse
Affiliation(s)
- Adam Shaw
- />Acoustics and Ionizing Radiation Division, National Physical Laboratory, Teddington, Middlesex UK
| | - Eleanor Martin
- />Acoustics and Ionizing Radiation Division, National Physical Laboratory, Teddington, Middlesex UK
- />Present address: Biomedical Ultrasound Group, University College London, London, UK
| | - Julian Haller
- />Physikalisch-Technische Bundesanstalt, Braunschweig, Germany
| | - Gail ter Haar
- />Division of Radiotherapy and Imaging, Institute for Cancer Research, Sutton, Surrey UK
| |
Collapse
|
22
|
Wilkens V, Sonntag S, Georg O. Robust spot-poled membrane hydrophones for measurement of large amplitude pressure waveforms generated by high intensity therapeutic ultrasonic transducers. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2016; 139:1319-1332. [PMID: 27036269 DOI: 10.1121/1.4944693] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
The output characterization of medical high intensity therapeutic ultrasonic devices poses several challenges for the hydrophones to be used for pressure measurements. For measurements at clinical levels in the focal region, extreme robustness, broad bandwidth, large dynamic range, and small receiving element size are all needed. Conventional spot-poled membrane hydrophones, in principle, meet some of these features and were used to detect large amplitude ultrasonic fields to investigate their applicability. Cavitation in water was the limiting effect causing damage to the electrodes and membrane. A new hydrophone design comprising a steel foil front protection layer has been developed, manufactured, characterized, tested, and optimized. The latest prototypes additionally incorporate a low absorption and acoustic impedance matched backing, and could be used for maximum peak rarefactional and peak compressional pressure measurements of 15 and 75 MPa, respectively, at 1.06 MHz driving frequency. Axial and lateral beam profiles were measured also for a higher driving frequency of 3.32 MHz to demonstrate the applicability for output beam characterization at the focal region at clinical levels. The experimental results were compared with results of numerical nonlinear sound field simulations and good agreement was found if detection bandwidth and spatial averaging were taken into account.
Collapse
Affiliation(s)
- Volker Wilkens
- Physikalisch-Technische Bundesanstalt, Bundesallee 100, 38116 Braunschweig, Germany
| | - Sven Sonntag
- Gesellschaft für Angewandte Medizinische Physik und Technik, Hallesche Strasse 99f, 06217 Merseburg, Germany
| | - Olga Georg
- Physikalisch-Technische Bundesanstalt, Bundesallee 100, 38116 Braunschweig, Germany
| |
Collapse
|
23
|
Affiliation(s)
- Gail ter Haar
- Joint Physics department, The Institute of Cancer Research , Sutton , London, UK
| |
Collapse
|