Tong N, Liu F, Zhang T, Wang L, Zhou Z, Gong H, Yuan F. Pigment dispersion syndrome and pigmentary glaucoma after secondary sulcus transscleral fixation of single-piece foldable posterior chamber intraocular lenses in Chinese aphakic patients.
J Cataract Refract Surg 2019;
43:639-642. [PMID:
28602325 DOI:
10.1016/j.jcrs.2017.02.026]
[Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2016] [Revised: 02/21/2017] [Accepted: 02/21/2017] [Indexed: 11/27/2022]
Abstract
PURPOSE
To describe secondary pigment dispersion syndrome (PDS) and pigmentary glaucoma after secondary sulcus transscleral fixation of 1-piece hydrophobic acrylic foldable posterior chamber intraocular lenses (PC IOLs) in aphakic patients in a Chinese population.
SETTING
Department of Ophthalmology, Qingdao Municipal Hospital, Qingdao, China.
DESIGN
Retrospective case series.
METHODS
This chart review included eyes that had secondary sulcus transscleral fixation of a 1-piece hydrophobic acrylic foldable PC IOL (Tecnis ZCB00) between March 2011 and March 2014. The patients' demographic data, clinical data, postoperative complications, intervals between initial surgery and the onset of PDS, pigmentary glaucoma occurrences, and findings on slitlamp biomicroscopy, gonioscopy, and ultrasound biomicroscopy (UBM) were recorded.
RESULTS
The study comprised 23 consecutive eyes of 21 patients. Seventeen eyes of 16 patients were diagnosed with PDS, and 7 eyes of 6 patients were diagnosed with pigmentary glaucoma. The slitlamp examination and UBM showed that the location between the IOL optic and the posterior surface of the iris was very close. Slitlamp examination of the anterior chamber angle using a gonioscope showed dense pigment deposition on the IOL surfaces. A reverse pupillary block was found in 10 eyes of 9 patients. Other postoperative complications included intraocular hemorrhage, pupillary capture of the IOL optic, IOL tilt, IOL decentration, IOL dislocation, and suture erosion.
CONCLUSION
The 1-piece hydrophobic acrylic foldable PC IOL was not suitable for sulcus transscleral fixation because of a high incidence of PDS and pigmentary glaucoma after surgery in a Chinese population.