1
|
Hatami-Marbini H, Mehr JA. Regional differences in electroactive response of the sclera. Proc Inst Mech Eng H 2024; 238:149-159. [PMID: 38294347 DOI: 10.1177/09544119231217240] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2024]
Abstract
The sclera exhibits mechanical response when subjected to an external electric stimulation. The scleral electroactive response is a function of its charge density, mechanical properties, thickness, and strength of the applied electric voltage. The primary objective of the present work was to investigate the regional differences in the electroactive response of porcine sclera. To this end, we cut scleral strips in meridional directions from superior-temporal, superior-nasal, inferior-temporal, and inferior-nasal quadrants. In addition, we excised samples circumferentially from the posterior, equatorial, and anterior regions. The electroactive bending response of these samples was measured under 10 and 15 V in 0.15 M NaCl solution. The meridional samples were tested under two different configurations by clamping them either from their anterior or posterior end. It was observed that the scleral electroactive deformation increased with increasing the the electric voltage. Furthermore, regardless of the region from which meridional strips were excised, their electroactive response was considerably larger when they were clamped from their anterior end. Unlike meridional strips, the electroactive response of circumferential samples was significantly dependent on the location, that is, the average maximum bending angle of posterior samples was significantly larger than that of equatorial and anterior strips. The regionally different electroactive bending response of the sclera was discussed in terms of the variation in its biochemical and biomechanical properties throughout the eyeball.
Collapse
Affiliation(s)
- Hamed Hatami-Marbini
- Computational Biomechanics Research Laboratory, Mechanical and Industrial Engineering Department, University of Illinois at Chicago, Chicago, IL, USA
| | - Jafar Arash Mehr
- Computational Biomechanics Research Laboratory, Mechanical and Industrial Engineering Department, University of Illinois at Chicago, Chicago, IL, USA
| |
Collapse
|
2
|
Mehr JA, Hatami-Marbini H. Finite Deformation of Scleral Tissue under Electrical Stimulation: An Arbitrary Lagrangian-Eulerian Finite Element Method. Bioengineering (Basel) 2023; 10:920. [PMID: 37627805 PMCID: PMC10451613 DOI: 10.3390/bioengineering10080920] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2023] [Revised: 06/28/2023] [Accepted: 07/13/2023] [Indexed: 08/27/2023] Open
Abstract
The sclera is considered as the principal load-bearing tissue within the eye. The sclera is negatively charged; thus, it exhibits mechanical response to electrical stimulation. We recently demonstrated the electroactive behavior of sclera by performing experimental measurements that captured the deformation of the tip of scleral strips subjected to electric voltage. We also numerically analyzed the electromechanical response of the tissue using a chemo-electro-mechanical model. In the pre-sent study, we extended our previous work by experimentally characterizing the deformation profile of scleral strips along their length under electrical stimulation. In addition, we improved our previous mathematical model such that it could numerically capture the large deformation of samples. For this purpose, we considered the transient variability of the fixed charge density and the coupling between mechanical and chemo-electrical phenomena. These improvements in-creased the accuracy of the computational model, resulting in a better numerical representation of experimentally measured bending angles.
Collapse
Affiliation(s)
| | - Hamed Hatami-Marbini
- Mechanical and Industrial Engineering Department, University of Illinois Chicago, Chicago, IL 60607, USA
| |
Collapse
|
3
|
Hatami-Marbini H, Emu ME. Effect of corneal collagen crosslinking on viscoelastic shear properties of the cornea. J Mech Behav Biomed Mater 2022; 133:105300. [PMID: 35749931 PMCID: PMC10826593 DOI: 10.1016/j.jmbbm.2022.105300] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2022] [Revised: 04/08/2022] [Accepted: 05/27/2022] [Indexed: 11/26/2022]
Abstract
The cornea is responsible for most of the refractive power in the eye and acts as a protective layer for internal contents of the eye. The cornea requires mechanical strength for maintaining its precise shape and for withstanding external and internal forces. Corneal collagen crosslinking (CXL) is a treatment option to improve corneal mechanical properties. The primary objective of this study was to characterize CXL effects on viscoelastic shear properties of the porcine cornea as a function of compressive strain. For this purpose, corneal buttons were prepared and divided into three groups: control group (n = 5), pseudo-crosslinked group (n = 5), and crosslinked group (n = 5). A rheometer was used to perform dynamics torsional shear experiments on corneal disks at different levels of compressive strain (0%-40%). Specifically, strain sweep experiments and frequency sweep tests were done in order to determine the range of linear viscoelasticity and frequency dependent shear properties, respectively. It was found that the shear properties of all samples were dependent on the shear strain magnitude, loading frequency, and compressive strain. With increasing the applied shear strain, all samples showed a nonlinear viscoelastic response. Furthermore, the shear modulus of samples increased with increasing the frequency of the applied shear strain and/or increasing the compressive strain. Finally, the CXL treatment significantly increased the shear storage and loss moduli when the compressive strain was varied from 0% to 30% (p < 0.05); larger shear moduli were observed at compressive 40% strain but the difference was not significant (P = 0.12).
Collapse
Affiliation(s)
- Hamed Hatami-Marbini
- Mechanical and Industrial Engineering Department, University of Illinois at Chicago, Chicago, IL, USA.
| | - Md Esharuzzaman Emu
- Mechanical and Industrial Engineering Department, University of Illinois at Chicago, Chicago, IL, USA
| |
Collapse
|
4
|
Hatami-Marbini H, Mehr JA. Modeling and experimental investigation of electromechanical properties of scleral tissue; a CEM model using an anisotropic hyperelastic constitutive relation. Biomech Model Mechanobiol 2022; 21:1325-1337. [PMID: 35962249 DOI: 10.1007/s10237-022-01590-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2021] [Accepted: 05/01/2022] [Indexed: 12/15/2022]
Abstract
The sclera is a soft tissue primarily consisting of collagen fibers, elastin, and proteoglycans. The proteoglycans are composed of a core protein and negatively charged glycosaminoglycan side chains. The fixed electric charges inside the scleral extracellular matrix play a key role in its swelling and are expected to cause the tissue to deform in response to an electric field. However, the electroactive response of the sclera has not yet been investigated. The present work experimentally demonstrates that sclera behaves similar to an anionic electrosensitive hydrogel and develops a chemo-electro-mechanical (CEM) mathematical framework for its electromechanical response. In the numerical model, a hyperelastic constitutive law with distributed collagen fibers is used to capture the nonlinear mechanical properties of the sclera, and the coupled Poisson-Nernst-Planck equations represent the distribution of mobile ions throughout the domain. After calibrating the proposed numerical CEM model against the experimental measurements, we employ it to investigate the effects of different parameters on the scleral electromechanical response including the voltage and fixed charge density. The experimental and numerical findings of the present study confirm that sclera behaves as an electroactive hydrogel and provide new insight into the mechanical response of this ocular tissue.
Collapse
Affiliation(s)
- Hamed Hatami-Marbini
- Mechanical and Industrial Engineering Department, University of Illinois at Chicago, 2039 Engineering Research Facility, 842 West Taylor St, Chicago, IL, 60607, USA.
| | - Jafar Arash Mehr
- Mechanical and Industrial Engineering Department, University of Illinois at Chicago, 2039 Engineering Research Facility, 842 West Taylor St, Chicago, IL, 60607, USA
| |
Collapse
|
5
|
Neroev VV, Iomdina EN, Khandzhyan AT, Khodzhabekyan NV, Sengaeva MD, Ivanova AV, Seliverstov SV, Teplyakova KO, Goltsman GN. [Experimental study of the effect of corneal hydration and its biomechanical properties on the results of photorefractive keratectomy]. Vestn Oftalmol 2021; 137:68-75. [PMID: 34156780 DOI: 10.17116/oftalma202113703168] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Water content in the cornea may affect the outcome of its excimer laser ablation, especially in presbyopic patients with myopic refraction. This hypothesis can be tested by scanning the cornea in the terahertz (THz) range to determine its hydration level. PURPOSE To study the effect of hydration of the cornea determined by non-contact THz scanning and its biomechanical parameters on the results of photorefractive keratectomy (PRK) in an experiment. MATERIAL AND METHODS PRK was performed using the Nidek EC-5000 QUEST excimer laser on 8 rabbit eyes. Corneal hydration was evaluated by determining the reflection coefficient (RC) in the THz electromagnetic radiation range before PRK, after 3-5 days, and after 1, 2, 3, and 4 months. Clinical examination included autorefractometry, assessment of corneal thickness and other anatomical and optical parameters of the anterior eye segment (Galilei G6, Ziemer Ophthalmic Systems AG 6.0.2, Switzerland), measurement of corneal hysteresis (CH) and corneal resistance factor (CRF) using the Ocular Response Analyzer (ORA; Reichert, USA), as well as tear production (Schirmer test). RESULTS The initial water content in the cornea has a significant effect on the thickness of the removed layer, i.e. on the PRK effect, with correlation coefficient of Rs= -0.976 (p<0.01). The correlation between CH and the ablation depth is less pronounced (Rs=0.643), and CRF had no correlation with it (Rs= -0.089). Biomechanical indicators of the cornea depend on its hydration: changes in CH and CRF after excimer laser ablation qualitatively coincide with changes in RC, the correlation coefficient between RC and the initial value of CH is R= -0.619 (moderate negative correlation). CONCLUSION THz scanning is an effective non-contact technology for monitoring corneal hydration level. The mismatch of the hypoeffect of keratorefractive excimer laser intervention planned for patients with presbyopia with the actual outcome can be caused by individual decrease in the initial water content in the cornea.
Collapse
Affiliation(s)
- V V Neroev
- Helmholtz National Medical Research Center of Eye Diseases, Moscow, Russia
| | - E N Iomdina
- Helmholtz National Medical Research Center of Eye Diseases, Moscow, Russia
| | - A T Khandzhyan
- Helmholtz National Medical Research Center of Eye Diseases, Moscow, Russia
| | - N V Khodzhabekyan
- Helmholtz National Medical Research Center of Eye Diseases, Moscow, Russia
| | - M D Sengaeva
- Helmholtz National Medical Research Center of Eye Diseases, Moscow, Russia
| | - A V Ivanova
- Helmholtz National Medical Research Center of Eye Diseases, Moscow, Russia
| | | | | | - G N Goltsman
- Moscow Pedagogical State University, Moscow, Russia
| |
Collapse
|
6
|
Niemczyk M, Danielewska ME, Kostyszak MA, Lewandowski D, Iskander DR. The effect of intraocular pressure elevation and related ocular biometry changes on corneal OCT speckle distribution in porcine eyes. PLoS One 2021; 16:e0249213. [PMID: 33770135 PMCID: PMC7997020 DOI: 10.1371/journal.pone.0249213] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2020] [Accepted: 03/14/2021] [Indexed: 11/21/2022] Open
Abstract
The aim of this study was to evaluate the influence of increase in intraocular pressure (IOP) and cooccurring changes in ocular biometry parameters on the corneal optical coherence tomography (OCT) speckle distribution in ex-vivo experiments on porcine intact eyes. Twenty-three eyeballs were used in the inflation test where IOP in the anterior chamber was precisely set from 10 mmHg to 40 mmHg in steps of 5 mmHg and where eye biometry was utilized (IOL Master 700). To assess the influence of the duration of the experiment on the OCT speckle statistics, the second experiment was performed with 10 eyeballs at the constant IOP of 15 mmHg. Based on the OCT scans of central cornea (Copernicus REVO), spatial maps of the scale parameter (a) and the shape parameter (v) of the gamma distribution speckle model were estimated. The means of both parameters for each spatial map were computed within the 2 mm of the central stroma. Both distributional parameters statistically significantly varied with IOP and time (one way repeated measures ANOVA, all p-values < 0.001). The a parameter revealed a faster statistically significant increase in IOP up to 25 mmHg, regardless of time. Central corneal thickness (CCT), the anterior chamber depth, and the mean equivalent spherical power varied significantly with IOP, whereas CCT and axial length changed statistically significantly with time. Statistically significant correlation was found between CCT and the a parameter, after removing IOP as a confounding factor (r = −0.576, p < 0.001). The parameters of the gamma distribution can be used not only for identifying IOP induced changes in the optical scattering within the corneal stroma, but also in corneal geometry. The approach of corneal speckle analysis could be potentially utilized for an indirect and noninvasive assessment of some properties of corneal stroma.
Collapse
Affiliation(s)
- Marcela Niemczyk
- Department of Biomedical Engineering, Wroclaw University of Science and Technology, Wroclaw, Poland
- * E-mail:
| | - Monika E. Danielewska
- Department of Biomedical Engineering, Wroclaw University of Science and Technology, Wroclaw, Poland
| | - Malgorzata A. Kostyszak
- Department of Biomedical Engineering, Wroclaw University of Science and Technology, Wroclaw, Poland
| | - Daniel Lewandowski
- Department of Mechanics, Materials and Biomedical Engineering, Wroclaw University of Science and Technology, Wroclaw, Poland
| | - D. Robert Iskander
- Department of Biomedical Engineering, Wroclaw University of Science and Technology, Wroclaw, Poland
| |
Collapse
|
7
|
Pachenari M, Hatami-Marbini H. Regional Differences in the Glycosaminoglycan Role in Porcine Scleral Hydration and Mechanical Behavior. Invest Ophthalmol Vis Sci 2021; 62:28. [PMID: 33749719 PMCID: PMC7991977 DOI: 10.1167/iovs.62.3.28] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Purpose This study characterized the role of glycosaminoglycans (GAGs) in the hydration, thickness, and biomechanical properties of posterior and anterior porcine sclera. Methods The scleral discs and strips were obtained from the anterior and posterior parts of porcine eyes, and their initial hydration and thickness were measured. The anterior and posterior scleral discs were used to show the efficacy of the GAG removal protocol by quantifying their GAG content. The strips were divided into three groups of PBS treatment, buffer treatment, and enzyme treatment in order to assess the effects of different treatment procedures on the thickness, hydration, and viscoelastic properties of the samples. The mechanical properties of the strips were determined by performing uniaxial tensile stress relaxation experiments. Results It was found that the control and buffer groups had insignificant differences in all measured quantities. The samples from the posterior region had a significantly larger GAG content and thickness in comparison with those from anterior region; however, there was an insignificant difference in their hydration. The GAG depletion process decreased the hydration of both anterior and posterior samples significantly (P < 0.05). Furthermore, the mechanical tests showed that the removal of GAGs resulted in stiffer mechanical behavior in both anterior and posterior samples (P < 0.05). In particular, the peak stress and equilibrium stress were significantly larger for the strips in the enzyme treatment group. Conclusions GAGs and their interaction with the collagen network are important in defining the hydration and mechanical properties of both posterior and anterior sclera.
Collapse
Affiliation(s)
- Mohammad Pachenari
- Computational Biomechanics Research Laboratory, Mechanical and Industrial Engineering Department, University of Illinois at Chicago, Chicago, Illinois, United States
| | - Hamed Hatami-Marbini
- Computational Biomechanics Research Laboratory, Mechanical and Industrial Engineering Department, University of Illinois at Chicago, Chicago, Illinois, United States
| |
Collapse
|
8
|
Urwin L, Okurowska K, Crowther G, Roy S, Garg P, Karunakaran E, MacNeil S, Partridge LJ, Green LR, Monk PN. Corneal Infection Models: Tools to Investigate the Role of Biofilms in Bacterial Keratitis. Cells 2020; 9:E2450. [PMID: 33182687 PMCID: PMC7696224 DOI: 10.3390/cells9112450] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2020] [Revised: 11/06/2020] [Accepted: 11/07/2020] [Indexed: 12/15/2022] Open
Abstract
Bacterial keratitis is a corneal infection which may cause visual impairment or even loss of the infected eye. It remains a major cause of blindness in the developing world. Staphylococcus aureus and Pseudomonas aeruginosa are common causative agents and these bacterial species are known to colonise the corneal surface as biofilm populations. Biofilms are complex bacterial communities encased in an extracellular polymeric matrix and are notoriously difficult to eradicate once established. Biofilm bacteria exhibit different phenotypic characteristics from their planktonic counterparts, including an increased resistance to antibiotics and the host immune response. Therefore, understanding the role of biofilms will be essential in the development of new ophthalmic antimicrobials. A brief overview of biofilm-specific resistance mechanisms is provided, but this is a highly multifactorial and rapidly expanding field that warrants further research. Progression in this field is dependent on the development of suitable biofilm models that acknowledge the complexity of the ocular environment. Abiotic models of biofilm formation (where biofilms are studied on non-living surfaces) currently dominate the literature, but co-culture infection models are beginning to emerge. In vitro, ex vivo and in vivo corneal infection models have now been reported which use a variety of different experimental techniques and animal models. In this review, we will discuss existing corneal infection models and their application in the study of biofilms and host-pathogen interactions at the corneal surface.
Collapse
Affiliation(s)
- Lucy Urwin
- Department of Infection, Immunity and Cardiovascular Disease, University of Sheffield, Sheffield S10 2RX, UK; (L.R.G.); (P.N.M.)
| | - Katarzyna Okurowska
- Department of Chemical and Biological Engineering, University of Sheffield, Sheffield S1 3JD, UK; (K.O.); (G.C.); (E.K.)
- Sheffield Collaboratorium for Antimicrobial Resistance and Biofilms (SCARAB), University of Sheffield, Sheffield S1 3JD, UK; (S.M.); (L.J.P.)
| | - Grace Crowther
- Department of Chemical and Biological Engineering, University of Sheffield, Sheffield S1 3JD, UK; (K.O.); (G.C.); (E.K.)
- Sheffield Collaboratorium for Antimicrobial Resistance and Biofilms (SCARAB), University of Sheffield, Sheffield S1 3JD, UK; (S.M.); (L.J.P.)
| | - Sanhita Roy
- Prof. Brien Holden Eye Research Centre, LV Prasad Eye Institute, Hyderabad 500034, India; (S.R.); (P.G.)
| | - Prashant Garg
- Prof. Brien Holden Eye Research Centre, LV Prasad Eye Institute, Hyderabad 500034, India; (S.R.); (P.G.)
| | - Esther Karunakaran
- Department of Chemical and Biological Engineering, University of Sheffield, Sheffield S1 3JD, UK; (K.O.); (G.C.); (E.K.)
- Sheffield Collaboratorium for Antimicrobial Resistance and Biofilms (SCARAB), University of Sheffield, Sheffield S1 3JD, UK; (S.M.); (L.J.P.)
| | - Sheila MacNeil
- Sheffield Collaboratorium for Antimicrobial Resistance and Biofilms (SCARAB), University of Sheffield, Sheffield S1 3JD, UK; (S.M.); (L.J.P.)
- Department of Materials Science and Engineering, University of Sheffield, Sheffield S1 3JD, UK
| | - Lynda J. Partridge
- Sheffield Collaboratorium for Antimicrobial Resistance and Biofilms (SCARAB), University of Sheffield, Sheffield S1 3JD, UK; (S.M.); (L.J.P.)
- Department of Molecular Biology and Biotechnology, University of Sheffield, Sheffield S10 2TN, UK
| | - Luke R. Green
- Department of Infection, Immunity and Cardiovascular Disease, University of Sheffield, Sheffield S10 2RX, UK; (L.R.G.); (P.N.M.)
| | - Peter N. Monk
- Department of Infection, Immunity and Cardiovascular Disease, University of Sheffield, Sheffield S10 2RX, UK; (L.R.G.); (P.N.M.)
- Sheffield Collaboratorium for Antimicrobial Resistance and Biofilms (SCARAB), University of Sheffield, Sheffield S1 3JD, UK; (S.M.); (L.J.P.)
| |
Collapse
|
9
|
Hydration related changes in tensile response of posterior porcine sclera. J Mech Behav Biomed Mater 2020; 104:103562. [DOI: 10.1016/j.jmbbm.2019.103562] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2019] [Revised: 11/05/2019] [Accepted: 11/26/2019] [Indexed: 11/18/2022]
|
10
|
Hatami-Marbini H, Pachenari M. The contribution of sGAGs to stress-controlled tensile response of posterior porcine sclera. PLoS One 2020; 15:e0227856. [PMID: 32084141 PMCID: PMC7034872 DOI: 10.1371/journal.pone.0227856] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2019] [Accepted: 12/31/2019] [Indexed: 11/19/2022] Open
Abstract
Despite the significant progress in characterizing mechanical functions of individual scleral extracellular matrix (ECM) components, the biomechanical contribution of sulfated glycosaminoglycans (sGAGs) is still poorly understood. The primary purpose of this study was to determine the possible function of sGAGs in scleral mechanical response by characterizing the tensile behavior of normal and sGAG-depleted samples. We used chondroitinase ABC solution to remove sGAGs from scleral samples that were dissected from posterior porcine eyes. We performed biochemical analyses for assessing the efficacy of sGAG removal protocol. Furthermore, we conducted stress-controlled uniaxial tensile tests to characterize the influence of sGAG removal on mechanical properties of sclera. The tensile behavior of scleral strips right after dissection and after being soaked in buffer was also determined. Biochemical analyses confirmed that 18 hour incubation in 0.125 U/ml Chondroitinase ABC solution removed over 90% of chondroitin and dermatan sGAGs. No significant difference was observed in the thickness/hydration of samples because of enzyme- and buffer-treated samples. Furthermore, it was found that sGAG depletion did not significantly alter the tangent modulus, energy dissipation, and peak strain of posterior scleral strips. It was concluded that sGAGs did not influence the stress-controlled viscoelastic tensile response of sclera.
Collapse
Affiliation(s)
- Hamed Hatami-Marbini
- Mechanical and Industrial Engineering Department, University of Illinois at Chicago, Chicago, Illinois, United States of America
| | - Mohammad Pachenari
- Mechanical and Industrial Engineering Department, University of Illinois at Chicago, Chicago, Illinois, United States of America
| |
Collapse
|
11
|
Song YW, Pan ZQ. Reducing porcine corneal graft rejection, with an emphasis on porcine endogenous retrovirus transmission safety: a review. Int J Ophthalmol 2019; 12:324-332. [PMID: 30809491 DOI: 10.18240/ijo.2019.02.21] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2018] [Accepted: 11/28/2018] [Indexed: 01/08/2023] Open
Abstract
Donor cornea shortage is a primary hurdle in the development of corneal transplantation. Of all species, porcine corneas are the ideal transplantation material for humans. However, the xenoimmune rejection induced by porcine corneal xenotransplantation compromises surgical efficacy. Although the binding of IgM/IgG in human serum to a genetically modified porcine cornea is significantly weaker than that of the wild type (WT), genetically modified porcine corneas do not display a prolonged graft survival time in vivo. Conversely, costimulatory blockade drugs, such as anti-CD40 antibodies, can reduce the xenoimmune response and prolong graft survival time in animal experiments. Moreover, porcine endothelial grafts can survive for more than 6mo with only the subconjunctival injection of a steroid-based immunosuppressants regime; therefore, they show great value for treating corneal endothelial disease. In addition, zoonotic transmission is a primary concern of xenotransplantation. Porcine endogenous retrovirus (PERV) is the most significant virus assessed by ophthalmologists. PERV integrates into the porcine genome and infects human cells in vitro. Fortunately, no evidence from in vivo studies has yet shown that PERV can be transmitted to hosts.
Collapse
Affiliation(s)
- Yao-Wen Song
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology and Visual Science Key Laboratory, Beijing 100730, China
| | - Zhi-Qiang Pan
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology and Visual Science Key Laboratory, Beijing 100730, China
| |
Collapse
|
12
|
Relationship between initial corneal hydration and stiffening effects of corneal crosslinking treatment. J Cataract Refract Surg 2018; 44:756-764. [PMID: 30041742 DOI: 10.1016/j.jcrs.2018.01.036] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2017] [Revised: 11/18/2017] [Accepted: 01/17/2018] [Indexed: 11/21/2022]
Abstract
PURPOSE To characterize the mechanical property improvement of riboflavin and ultraviolet light corneal crosslinking (CXL) procedure in artificially swollen human and porcine corneas. SETTING Computational Biomechanics Research Laboratory, Mechanical and Industrial Engineering Department, University of Illinois at Chicago, Illinois, USA. DESIGN Experimental study. METHODS Porcine and human donor corneas were crosslinked at different hydration levels using riboflavin-dextran solutions of different osmolality. Four porcine groups (Hw [hydration in mg H2O/mg dry tissue] = 3.3 ± 0.2 [SD]; 4.0 ± 0.1; 5.1 ± 0.1; 5.6 ± 0.1) and 3 human groups (Hw = 3.2 ± 0.1; 3.9 ± 0.2; 5.3 ± 0.3) were considered. The mechanical properties were measured by uniaxial tensile experiments during which the hydration of samples was the same as the hydration at which they were crosslinked. Tensile properties of 2 porcine groups (Hw = 5.1 ± 0.1; 5.6 ± 0.1) were also measured when their average hydration was lowered to 4.0 mg H2O/mg dry tissue. RESULTS The CXL procedure significantly increased tensile properties of both human and porcine samples in each hydration group (P < .05). The improvement in tensile properties was hydration-dependent, that is, samples crosslinked at higher hydration levels showed lower maximum tensile stress. The behavior of samples crosslinked at different initial hydration but tested mechanically at similar hydration showed insignificant difference (P = .7). CONCLUSION Increasing the hydration of porcine and human corneal samples before the CXL treatment had insignificant influence on tensile property improvement, as measured by testing specimens at similar hydration.
Collapse
|
13
|
Chang SH, Mohammadvali A, Chen KJ, Ji YR, Young TH, Wang TJ, Willoughby CE, Hamill KJ, Elsheikh A. The Relationship Between Mechanical Properties, Ultrastructural Changes, and Intrafibrillar Bond Formation in Corneal UVA/Riboflavin Cross-linking Treatment for Keratoconus. J Refract Surg 2018; 34:264-272. [PMID: 29634842 DOI: 10.3928/1081597x-20180220-01] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2017] [Accepted: 01/10/2018] [Indexed: 11/20/2022]
Abstract
PURPOSE To determine the relationship between mechanical behavior in cross-linked corneas and changes in the corneal ultrastructure after corneal cross-linking (CXL). METHODS Porcine corneas were treated following the "Dresden" protocol, the current gold standard for clinical treatment, consisting of dropwise application of 0.1% riboflavin in 20% dextran followed by 30 minutes of ultraviolet-A (UVA) irradiation. The effect of CXL was assessed using uniaxial tensile testing, transmission electron microscopy, and Fourier transform infrared spectroscopy, with results compared against corneas treated with each of the treatment solution components individually. RESULTS UVA/riboflavin cross-linked corneas displayed 28% ± 17% increase in the material tangent modulus compared with dextran treatment alone, and altered collagen architecture within the first 300 µm of stromal depth consisting of 5% increase in the thickness of collagen fibrils, no significant changes to interfibrillar spacing, and an 8% to 12% decrease in number of fibrils per unit area. Fourier transform infrared spectroscopy confirmed formation of interfibrillar bonds (P = .012) induced by UVA-mediated CXL. CONCLUSIONS The data support a model wherein collagen fibril diameter and structural density are fundamental parameters in defining tissue stiffening following UVA/riboflavin CXL and provide benchmarks against which modifications to the Dresden CXL protocol can be evaluated. [J Refract Surg. 2018;34(4):264-272.].
Collapse
|
14
|
Hatami-Marbini H, Jayaram SM. UVA/riboflavin collagen crosslinking stiffening effects on anterior and posterior corneal flaps. Exp Eye Res 2018; 176:53-58. [PMID: 29777678 DOI: 10.1016/j.exer.2018.05.014] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2018] [Revised: 05/04/2018] [Accepted: 05/15/2018] [Indexed: 10/16/2022]
Abstract
The UVA/riboflavin collagen crosslinking (CXL) is one of the treatment procedure for stopping the progression of keratoconus. The inclusion criterion for this procedure is a minimum corneal thickness of 400 μm, which is not often met in patients with advanced keratoconus. Preoperatively swelling thin corneas was shown to stabilize the keratectasia without any postoperative endothelial damage. Recently, we have shown that swelling porcine corneas prior to the CXL treatment had no significant effect on the resulting improvement in their tensile properties. In the present study, we extended this previous study and characterized the stiffening effects of CXL on anterior and posterior flaps as a function of their hydration. A DSAEK system was used to excise 10 mm corneal flaps from 80 porcine corneas. Individual flaps were crosslinked at different initial hydration levels by using riboflavin solutions composed of different dextran concentrations; the thickness was taken as a measure of flap hydration. A DMA machine was used to measure the tensile properties either immediately after the CXL treatment or after the thickness (hydration) of the crosslinked samples was brought down to a specific value. The average thickness of anterior groups was 670 μm, 540 μm, and 410 μm, and the average thickness of posterior groups was 845 μm, 650 μm, and 440 μm. It was found that although CXL significantly increased the tensile properties of all anterior groups, it had an insignificant effect on the stiffness of posterior flaps. Furthermore, except for the posterior flaps in 845 μm and 650 μm thickness groups, decreasing the hydration significantly increased the tensile modulus (p < 0.05). Finally, the anterior flaps that were crosslinked at higher hydration, i.e. swollen before CXL, showed significantly less amount of stiffening in comparison with those crosslinked at lower hydration when the tensile property measurement was done at similar hydration (p < 0.05).
Collapse
Affiliation(s)
- Hamed Hatami-Marbini
- Computational Biomechanics Research Laboratory, Mechanical and Industrial Engineering Department, University of Illinois at Chicago, Chicago, IL, USA.
| | - Sandeep M Jayaram
- Computational Biomechanics Research Laboratory, Mechanical and Industrial Engineering Department, University of Illinois at Chicago, Chicago, IL, USA
| |
Collapse
|
15
|
Abstract
Cell migration is an adaptive process that depends on and responds to physical and molecular triggers. Moving cells sense and respond to tissue mechanics and induce transient or permanent tissue modifications, including extracellular matrix stiffening, compression and deformation, protein unfolding, proteolytic remodelling and jamming transitions. Here we discuss how the bi-directional relationship of cell-tissue interactions (mechanoreciprocity) allows cells to change position and contributes to single-cell and collective movement, structural and molecular tissue organization, and cell fate decisions.
Collapse
|
16
|
Kling S, Hafezi F. Corneal biomechanics - a review. Ophthalmic Physiol Opt 2017; 37:240-252. [PMID: 28125860 DOI: 10.1111/opo.12345] [Citation(s) in RCA: 95] [Impact Index Per Article: 13.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2016] [Accepted: 11/15/2016] [Indexed: 12/01/2022]
Abstract
PURPOSE In recent years, the interest in corneal biomechanics has strongly increased. The material properties of the cornea determine its shape and therefore play an important role in corneal ectasia and related pathologies. This review addresses the molecular origin of biomechanical properties, models for their description, methods for their characterisation, techniques for their modification, and computational simulation approaches. RECENT FINDINGS Recent research has focused on developing non-contact techniques to measure the biomechanical properties in vivo, on determining structural and molecular abnormalities in pathological corneas, on developing and optimising techniques to reinforce the corneal tissue and on the computational simulation of surgical interventions. SUMMARY A better understanding of corneal biomechanics will help to improve current refractive surgeries, allow an earlier diagnosis of ectatic disorders and a better quantification of treatments aiming at reinforcing the corneal tissue.
Collapse
Affiliation(s)
- Sabine Kling
- CABMM, University of Zurich, Zurich, Switzerland
| | - Farhad Hafezi
- CABMM, University of Zurich, Zurich, Switzerland.,ELZA Institute AG Dietikon, Zurich, Switzerland.,USC Roski Eye Institute - Keck School of Medicine, Los Angeles, USA.,Ophthalmology, University of Geneva, Geneva, Switzerland
| |
Collapse
|
17
|
Sun MT, Wood M, Chan W, Casson R. Pressures generated during corneal wound hydration. J Cataract Refract Surg 2016; 42:1383-1384. [PMID: 27697259 DOI: 10.1016/j.jcrs.2016.07.026] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2016] [Accepted: 07/20/2016] [Indexed: 11/29/2022]
|
18
|
Hatami-Marbini H, Rahimi A. Interrelation of Hydration, Collagen Cross-Linking Treatment, and Biomechanical Properties of the Cornea. Curr Eye Res 2015; 41:616-22. [PMID: 26126201 DOI: 10.3109/02713683.2015.1042546] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
PURPOSE The present study was designed to investigate the effects of hydration and collagen cross-linking treatment on biomechanical properties of the cornea. METHODS The original corneal collagen cross-linking protocol was used to induce cross-links in bovine corneas. The thickness of samples was used as a measure of their hydration and five different thickness groups (n = 5 each) were considered. The cross-linked corneal strips were allowed to hydrate/dehydrate until their thickness reached 500, 700, 900, 1100, and 1500 μm. The tensile behavior of specimens in each thickness group was characterized by conducting uniaxial tensile experiments. The experiments were done in mineral oil in order to keep the thickness of samples constant and minimize hydration changes. RESULTS It was observed that collagen cross-linking treatment significantly increased both the maximum tensile stress and the equilibrium (relaxed) stress of the bovine cornea (p < 0.01). Furthermore, with increasing the thickness (hydration) of the collagen cross-linked samples, their tensile stiffness significantly decreased (p < 0.01). An exponential relation and a logarithmic expression successfully represented experimentally measured stress-strain behavior and relaxation response of all groups (r(2 )> 0.99), respectively. CONCLUSION Hydration and collagen cross-linking treatment concomitantly affect biomechanical properties of the cornea. Therefore, an accurate estimate of stiffening effects of collagen cross-linking treatment option using uniaxial tensile experiments is only possible if the hydration of specimens is fully controlled.
Collapse
Affiliation(s)
- Hamed Hatami-Marbini
- a Computational Biomechanics Laboratory, School of Mechanical and Aerospace Engineering, Oklahoma State University , Stillwater , OK , USA
| | - Abdolrasol Rahimi
- a Computational Biomechanics Laboratory, School of Mechanical and Aerospace Engineering, Oklahoma State University , Stillwater , OK , USA
| |
Collapse
|
19
|
Hatami-Marbini H, Rahimi A. Evaluation of hydration effects on tensile properties of bovine corneas. J Cataract Refract Surg 2015; 41:644-51. [DOI: 10.1016/j.jcrs.2014.07.029] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2014] [Revised: 06/12/2014] [Accepted: 07/11/2014] [Indexed: 11/27/2022]
|
20
|
Hatami-Marbini H, Rahimi A. Stiffening effects of riboflavin/UVA corneal collagen cross-linking is hydration dependent. J Biomech 2015; 48:1052-7. [PMID: 25704532 DOI: 10.1016/j.jbiomech.2015.01.038] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2014] [Revised: 10/03/2014] [Accepted: 01/25/2015] [Indexed: 10/24/2022]
Abstract
The collagen cross-linking is a relatively new treatment option for strengthening the cornea, delaying, and in some cases stopping the progression of keratoconus. The uniaxial tensile experiments are among the most commonly used techniques to assess the effectiveness of this therapeutic option in enhancing tensile properties. In the present study, we investigated the possible effects of hydration on stiffening effects of corneal collagen cross-linking procedure, as measured by the uniaxial tensile testing method. For this purpose, after cross-linking bovine corneas, we let the strips to dehydrate in air or swell in a solution until their thickness reached an average thickness of 0.5, 0.7, 0.9, 1.1, and 1.5 mm. Using thickness as a representative of hydration, we divided corneal strips into five different groups and measured their stress-strain behavior by conducting uniaxial tensile experiments in mineral oil. It was observed that the collagen cross-linking treatment and hydration together affect the tensile behavior of the bovine cornea. While corneal collagen cross-linking resulted in a significant increase in the tensile stress-strain response of each thickness group (P<0.01), less hydrated collagen cross-linked samples showed a significantly stiffer response (P<0.01). A master curve was found for representing the tensile behavior of the collagen cross-linked bovine cornea at different levels of hydration. The results of the present research confirmed that the amount of mechanical stiffening of the corneal collagen cross-linking, as measured by uniaxial tensile testing, strongly depends on the hydration. Therefore, it is concluded that uniaxial tensile experiments could only be used to assess stiffening effects of the collagen cross-linking treatment if the hydration of specimens is fully controlled.
Collapse
Affiliation(s)
- H Hatami-Marbini
- School of Mechanical and Aerospace Engineering, Oklahoma State University, Stillwater, OK 74078, United States.
| | - A Rahimi
- School of Mechanical and Aerospace Engineering, Oklahoma State University, Stillwater, OK 74078, United States
| |
Collapse
|
21
|
Hatami-Marbini H, Rahimi A. The relation between hydration and mechanical behavior of bovine cornea in tension. J Mech Behav Biomed Mater 2014; 36:90-7. [DOI: 10.1016/j.jmbbm.2014.03.011] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2014] [Revised: 03/15/2014] [Accepted: 03/18/2014] [Indexed: 11/30/2022]
|
22
|
Xia D, Zhang S, Hjortdal JØ, Li Q, Thomsen K, Chevallier J, Besenbacher F, Dong M. Hydrated human corneal stroma revealed by quantitative dynamic atomic force microscopy at nanoscale. ACS NANO 2014; 8:6873-82. [PMID: 24833346 DOI: 10.1021/nn5015837] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
The structures and mechanical properties of human tissues are significantly influenced by water. The functionality of the human cornea can be linked to the hydrated collagen fibers. By applying quantitative dynamic atomic force microscopy to investigate morphological and mechanical property variations of corneal stroma under different hydration levels, we found that the collagen fibers in the stromal tissue show the specific periodicities and the stiffness of giga-Pa magnitude at 40% humidity. However, under increasing hydration, the collagen fibers clearly show nanoparticle structures along the fibers with the stiffness in mega-Pa magnitude. By increasing the hydration time, the stroma regains the fiber structure but with larger diameter. The age-dependency in stiffness was further investigated. The interplay of structures and nanomechanical mapping may be applied for the future diagnosis and assessment or even pathologic analysis.
Collapse
Affiliation(s)
- Dan Xia
- Interdisciplinary Nanoscience Center (iNANO), Centre for DNA Nanotechnology (CDNA), Aarhus University , 8000 Aarhus, Denmark
| | | | | | | | | | | | | | | |
Collapse
|
23
|
Hydration dependent viscoelastic tensile behavior of cornea. Ann Biomed Eng 2014; 42:1740-8. [PMID: 24668183 DOI: 10.1007/s10439-014-0996-6] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2013] [Accepted: 03/07/2014] [Indexed: 10/25/2022]
Abstract
The cornea is a protective transparent connective tissue covering the front of the eye. The standard uniaxial tensile experiments are among the most popular techniques for investigating biomechanical properties of the cornea. This experimental method characterizes the stress-strain response of corneal strips immersed in a bathing solution. In the present study, the important roles of corneal hydration on tensile viscoelastic properties were investigated. The thickness was used as a surrogate for hydration and uniaxial tensile experiments were performed on bovine corneal samples with four different average thickness (hydration), i.e., 1100 μm (4.87 mg water/mg dry tissue), 900 μm (4.13 mg water/mg dry tissue), 700 μm (3.20 mg water/mg dry tissue), and 500 μm (1.95 mg water/mg dry tissue). The samples were immersed in mineral oil in order to prevent their swelling during the experiments. A quasilinear viscoelastic (QLV) model was used to analyze the experimental measurements and determine viscoelastic material constants. It was observed that both maximum and equilibrium (relaxed) stresses were exponentially increased with decreasing tissue thickness (hydration). Furthermore, the QLV model successfully captured the corneal viscoelastic response with an average R (2) value greater than 0.99. Additional experiments were conducted in OBSS in order to confirm that these significant changes in viscoelastic properties were because of corneal hydration and not the bathing solution. The findings of this study suggest that extra care must be taken in interpreting the results of earlier uniaxial tensile testings and their correspondence to the corneal biomechanical properties.
Collapse
|
24
|
Hatami-Marbini H, Rahimi A. Effects of bathing solution on tensile properties of the cornea. Exp Eye Res 2014; 120:103-8. [DOI: 10.1016/j.exer.2013.11.017] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2013] [Revised: 11/21/2013] [Accepted: 11/26/2013] [Indexed: 11/29/2022]
|
25
|
Viscoelastic shear properties of the corneal stroma. J Biomech 2014; 47:723-8. [DOI: 10.1016/j.jbiomech.2013.11.019] [Citation(s) in RCA: 43] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2013] [Revised: 11/14/2013] [Accepted: 11/18/2013] [Indexed: 11/23/2022]
|
26
|
Hatami-Marbini H, Etebu E. Hydration dependent biomechanical properties of the corneal stroma. Exp Eye Res 2013; 116:47-54. [DOI: 10.1016/j.exer.2013.07.016] [Citation(s) in RCA: 71] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2013] [Revised: 06/21/2013] [Accepted: 07/15/2013] [Indexed: 11/17/2022]
|