1
|
Komninou MA, Seiler TG, Enzmann V. Corneal biomechanics and diagnostics: a review. Int Ophthalmol 2024; 44:132. [PMID: 38478103 PMCID: PMC10937779 DOI: 10.1007/s10792-024-03057-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2022] [Accepted: 02/16/2024] [Indexed: 03/17/2024]
Abstract
PURPOSE Corneal biomechanics is an emerging field and the interest into physical and biological interrelations in the anterior part of the eye has significantly increased during the past years. There are many factors that determine corneal biomechanics such as hormonal fluctuations, hydration and environmental factors. Other factors that can affect the corneas are the age, the intraocular pressure and the central corneal thickness. The purpose of this review is to evaluate the factors affecting corneal biomechanics and the recent advancements in non-destructive, in vivo measurement techniques for early detection and improved management of corneal diseases. METHODS Until recently, corneal biomechanics could not be directly assessed in humans and were instead inferred from geometrical cornea analysis and ex vivo biomechanical testing. The current research has made strides in studying and creating non-destructive and contactless techniques to measure the biomechanical properties of the cornea in vivo. RESULTS Research has indicated that altered corneal biomechanics contribute to diseases such as keratoconus and glaucoma. The identification of pathological corneas through the new measurement techniques is imperative for preventing postoperative complications. CONCLUSIONS Identification of pathological corneas is crucial for the prevention of postoperative complications. Therefore, a better understanding of corneal biomechanics will lead to earlier diagnosis of ectatic disorders, improve current refractive surgeries and allow for a better postoperative treatment.
Collapse
Affiliation(s)
- Maria Angeliki Komninou
- Department of Ophthalmology, Bern University Hospital Inselspital, University of Bern, Bern, Switzerland
- Institute of Intensive Care Medicine, University Hospital Zurich & University of Zurich, Zurich, Switzerland
| | - Theo G Seiler
- Department of Ophthalmology, Bern University Hospital Inselspital, University of Bern, Bern, Switzerland
- Klinik Für Augenheilkunde, Universitätsklinikum Düsseldorf, Düsseldorf, Germany
- Institut Für Refraktive Und Opthalmo-Chirurgie (IROC), Zurich, Switzerland
- Wellman Center for Photomedicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Volker Enzmann
- Department of Ophthalmology, Bern University Hospital Inselspital, University of Bern, Bern, Switzerland.
- Department of BioMedical Research, University of Bern, Bern, Switzerland.
| |
Collapse
|
2
|
Liu MX, Li DL, Yin ZJ, Li YZ, Zheng YJ, Qin Y, Liang G, Pan CW. Smoking, alcohol consumption and corneal biomechanical parameters among Chinese university students. Eye (Lond) 2023; 37:2723-2729. [PMID: 36697900 PMCID: PMC10482929 DOI: 10.1038/s41433-023-02405-2] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2022] [Revised: 11/28/2022] [Accepted: 01/16/2023] [Indexed: 01/26/2023] Open
Abstract
BACKGROUND/OBJECTIVES Smoking and alcohol consumption are important risk factors for several ocular disorders, but their effects on corneal biomechanics remain unclear. Our study aims to explore the association between smoking and alcohol consumption with corneal biomechanical parameters measured by Corvis-ST (CST) among university students. SUBJECTS/METHODS A total of 1645 healthy university students from a university-based study were included, and all participants underwent corneal biomechanical parameters measurement by CST. We selected 10 reliable parameters that can reflect the corneal deformation response. All participants had a standardised interview to determine their smoking and alcohol consumption status. RESULTS The mean age of the participants was 19.0 ± 0.9 years, and 1132 (68.8%) were women. Smoking was significantly associated with stiffer corneas. Smokers showed significantly slower second applanation velocity (A2v) (β = 0.007 m/s, 95% confidence interval 0.001 to 0.014, P = 0.032) and lower integrated radius (IR) (β = -0.214 mm-1, 95% confidence interval -0.420 to -0.007, P = 0.043) than non-smokers after adjusting for age, gender, eye-rubbing, myopia, and body mass index (BMI). Smokers with BMI no less than 24.0 showed slower A2v and lower IR. Alcohol consumption and passive smoking were found no significant association with corneal biomechanics. CONCLUSION Smokers had less deformable corneas, especially those with BMI no less than 24.0. Our findings provide new evidence for the association between smoking and ocular disorders associated with corneal biomechanics like glaucoma.
Collapse
Affiliation(s)
- Min-Xin Liu
- School of Public Health, Medical College of Soochow University, Suzhou, China
| | - Dan-Lin Li
- School of Public Health, Medical College of Soochow University, Suzhou, China
| | - Zhi-Jian Yin
- Department of Ophthalmology, The First Affiliated Hospital of Dali University, Dali, China
| | - Yue-Zu Li
- Department of Ophthalmology, The Affiliated Hospital of Yunnan University, Kunming, China
- Department of Ophthalmology, The Second People's Hospital of Yunnan Province, Kunming, China
| | - Ya-Jie Zheng
- Department of Ophthalmology, The Affiliated Hospital of Yunnan University, Kunming, China
- Department of Ophthalmology, The Second People's Hospital of Yunnan Province, Kunming, China
| | - Yu Qin
- Department of Ophthalmology, The Affiliated Hospital of Yunnan University, Kunming, China
- Department of Ophthalmology, The Second People's Hospital of Yunnan Province, Kunming, China
| | - Gang Liang
- Department of Ophthalmology, The Affiliated Hospital of Yunnan University, Kunming, China.
- Department of Ophthalmology, The Second People's Hospital of Yunnan Province, Kunming, China.
| | - Chen-Wei Pan
- School of Public Health, Medical College of Soochow University, Suzhou, China.
| |
Collapse
|
3
|
Razeghinejad MR, Farsiani AR, Salout R, Owji N, Masoumpour M, Kharmandar A, Zamani M. Corneal biomechanical properties in hyperthyroidism and thyroid eye disease. Saudi J Ophthalmol 2021; 34:251-255. [PMID: 34527867 PMCID: PMC8409357 DOI: 10.4103/1319-4534.322605] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2019] [Revised: 04/21/2020] [Accepted: 07/06/2020] [Indexed: 11/17/2022] Open
Abstract
PURPOSE: The purpose of this study is to compare the corneal biomechanical properties of hyperthyroids without ophthalmopathy (HWO), thyroid eye disease (TED), and euthyroid participants. METHODS: In this prospective comparative study, one eye per patient included in the analysis and according to exclusion criteria, 38 eyes of 40 HWO patients, 31 eyes of 40 TED patients, and 150 eyes of 160 age- and sex-matched euthyroid participants were enrolled. All participants were evaluated by an endocrinologist and oculoplastic surgeon for evaluation of thyroid function and orbitopathy, respectively. Measurements of corneal biomechanical properties were performed using ocular response analyzer and Corvis ST tonometers. RESULTS: In the HWO group, applanation-1 length (A1 L), applanation-2 velocity (A2V) (P < 0.001), and corneal resistant factor (P = 0.043) were higher than the control group and corneal hysteresis (CH) was lower (P = 0.018). In the TED group, A1 L, A2V (P < 0.001), and highest concavity radius (HCR) (P = 0.027) were higher than the control group, and the CH (P = 0.007) and highest concavity deformation amplitude (HCDA) (P = 0.001) were lower. Furthermore, the level HCDA in the TED group was lower than HWO group (P = 0.011). The level of upper scleral show and palpebral fissure had a negative correlation with CH and HCDA. The amount of exophthalmos level had a positive correlation with HCR. CONCLUSION: Corneal biomechanical properties in the HWO and TED groups were different from the normal euthyroid individuals and may be taken into account in managing situation like glaucoma and refractive surgeries.
Collapse
Affiliation(s)
- M Reza Razeghinejad
- Poostchi Ophthalmology Research Center, Department of Ophthalmology, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran.,Glaucoma Research Center, Wills Eye Hospital, Philadelphia, PA, USA
| | - Amir R Farsiani
- Poostchi Ophthalmology Research Center, Department of Ophthalmology, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran.,Department of Ophthalmology, School of Medicine, Zanjan University of Medical sciences, Zanjan, Iran
| | - Ramin Salout
- Poostchi Ophthalmology Research Center, Department of Ophthalmology, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran.,Salouti Eye Research Center, Salouti Eye Clinic, Shiraz, Iran
| | - Naser Owji
- Poostchi Ophthalmology Research Center, Department of Ophthalmology, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Masoumeh Masoumpour
- Poostchi Ophthalmology Research Center, Department of Ophthalmology, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Alireza Kharmandar
- Endocrine and Metabolism Research Center, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Mohammad Zamani
- Salouti Eye Research Center, Salouti Eye Clinic, Shiraz, Iran
| |
Collapse
|
4
|
Yang Y, Ng TK, Wang L, Wu N, Xiao M, Sun X, Chen Y. Association of 24-Hour Intraocular Pressure Fluctuation With Corneal Hysteresis and Axial Length in Untreated Chinese Primary Open-Angle Glaucoma Patients. Transl Vis Sci Technol 2020; 9:25. [PMID: 33244445 PMCID: PMC7683862 DOI: 10.1167/tvst.9.12.25] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2020] [Accepted: 10/12/2020] [Indexed: 02/05/2023] Open
Abstract
PURPOSE The purpose of this study was to evaluate the association of 24-hour intraocular pressure (IOP) fluctuation with corneal biomechanics and ocular biometric parameters in Chinese patients with primary open angle glaucoma (POAG) before initial treatment. METHODS Forty-nine Chinese patients with POAG (98 eyes) were recruited in this study before start of any POAG treatment. The 24-hour IOP was measured with a 2-hour interval by a noncontact tonometer. Corneal biomechanical properties and biometric parameters were measured once during 8 AM to 6 PM before 24-hour IOP measurement. RESULTS The 24-hour IOP fluctuation was defined as the differences between the peak and trough IOP measurement and was significantly associated with axial length (AL) in the multivariate analysis. The POAG subjects with AL ≤ 26 mm had significantly larger 24-hour IOP fluctuation but lower corneal hysteresis, compared to those with AL > 26 mm. In addition, subgroup analysis showed that high tension glaucoma subjects had larger 24-hour IOP fluctuation and higher corneal resistance factor than patients with normal tension glaucoma. CONCLUSIONS This study revealed the association of 24-hour IOP fluctuation with office hour corneal biomechanical properties and AL in patients with POAG. Their contributions to IOP fluctuation should be considered in the risk analysis of glaucoma development and progression. TRANSLATIONAL RELEVANCE Ocular biometric parameters are related with 24-hour IOP fluctuation in patients with POAG, which is potentially helpful in explaining different progression patterns in different types of patients.
Collapse
Affiliation(s)
- Yaping Yang
- Department of Ophthalmology and Visual Science, Eye and Ear Nose Throat Hospital, Shanghai Medical College, Fudan University, Shanghai, China
- Key Laboratory of Myopia, Ministry of Health, Fudan University, Shanghai, China
- Key Laboratory of Visual Impairment and Restoration, Fudan University, Shanghai, China
| | - Tsz Kin Ng
- Joint Shantou International Eye Center of Shantou University and The Chinese University of Hong Kong, Shantou University Medical College, Shantou, Guangdong, China
- Department of Ophthalmology and Visual Sciences, The Chinese University of Hong Kong, Hong Kong
| | - Li Wang
- Department of Ophthalmology and Visual Science, Eye and Ear Nose Throat Hospital, Shanghai Medical College, Fudan University, Shanghai, China
- Key Laboratory of Myopia, Ministry of Health, Fudan University, Shanghai, China
- Key Laboratory of Visual Impairment and Restoration, Fudan University, Shanghai, China
| | - Na Wu
- Department of Ophthalmology and Visual Science, Eye and Ear Nose Throat Hospital, Shanghai Medical College, Fudan University, Shanghai, China
- Key Laboratory of Myopia, Ministry of Health, Fudan University, Shanghai, China
- Key Laboratory of Visual Impairment and Restoration, Fudan University, Shanghai, China
| | - Ming Xiao
- Department of Ophthalmology, Shanghai Bei Zhan Hospital, Shanghai, China
| | - Xinghuai Sun
- Department of Ophthalmology and Visual Science, Eye and Ear Nose Throat Hospital, Shanghai Medical College, Fudan University, Shanghai, China
- Key Laboratory of Myopia, Ministry of Health, Fudan University, Shanghai, China
- Key Laboratory of Visual Impairment and Restoration, Fudan University, Shanghai, China
- State Key Laboratory of Medical Neurobiology, Institutes of Brain Science and Collaborative Innovation Center for Brain Science, Fudan University, Shanghai, China
| | - Yuhong Chen
- Department of Ophthalmology and Visual Science, Eye and Ear Nose Throat Hospital, Shanghai Medical College, Fudan University, Shanghai, China
- Key Laboratory of Myopia, Ministry of Health, Fudan University, Shanghai, China
- Key Laboratory of Visual Impairment and Restoration, Fudan University, Shanghai, China
| |
Collapse
|
5
|
Hayek G, Luc M, Bloch F, Vermion J, Lhuillier L, Zaidi M, Goetz C, Perone JM. Tobacco smoking in crosslinked keratoconus patients. J Fr Ophtalmol 2019; 42:1001-1006. [DOI: 10.1016/j.jfo.2019.05.005] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2019] [Revised: 04/23/2019] [Accepted: 05/02/2019] [Indexed: 10/26/2022]
|
6
|
Zhang B, Shweikh Y, Khawaja AP, Gallacher J, Bauermeister S, Foster PJ. Associations with Corneal Hysteresis in a Population Cohort: Results from 96 010 UK Biobank Participants. Ophthalmology 2019; 126:1500-1510. [PMID: 31471087 DOI: 10.1016/j.ophtha.2019.06.029] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2019] [Revised: 06/07/2019] [Accepted: 06/28/2019] [Indexed: 11/16/2022] Open
Abstract
PURPOSE To describe the distribution of corneal hysteresis (CH) in a large cohort and explore its associated factors and possible clinical applications. DESIGN Cross-sectional study within the UK Biobank, a large cohort study in the United Kingdom. PARTICIPANTS We analyzed CH data from 93 345 eligible participants in the UK Biobank cohort, aged 40 to 69 years. METHODS All analyses were performed using left eye data. Linear regression models were used to evaluate associations between CH and demographic, lifestyle, ocular, and systemic variables. Piecewise logistic regression models were used to explore the relationship between self-reported glaucoma and CH. MAIN OUTCOME MEASURES Corneal hysteresis (mmHg). RESULTS The mean CH was 10.6 mmHg (10.4 mmHg in male and 10.8 mmHg in female participants). After adjusting for covariables, CH was significantly negatively associated with male sex, age, black ethnicity, self-reported glaucoma, diastolic blood pressure, and height. Corneal hysteresis was significantly positively associated with smoking, hyperopia, diabetes, systemic lupus erythematosus (SLE), greater deprivation (Townsend index), and Goldmann-correlated intraocular pressure (IOPg). Self-reported glaucoma and CH were significantly associated when CH was less than 10.1 mmHg (odds ratio, 0.86; 95% confidence interval, 0.79-0.94 per mmHg CH increase) after adjusting for covariables. When CH exceeded 10.1 mmHg, there was no significant association between CH and self-reported glaucoma. CONCLUSIONS In our analyses, CH was significantly associated with factors including age, sex, and ethnicity, which should be taken into account when interpreting CH values. In our cohort, lower CH was significantly associated with a higher prevalence of self-reported glaucoma when CH was less than 10.1 mmHg. Corneal hysteresis may serve as a biomarker aiding glaucoma case detection.
Collapse
Affiliation(s)
- Bing Zhang
- Department of Psychiatry, University of Oxford, Oxford, United Kingdom
| | - Yusrah Shweikh
- National Institute for Health Research Biomedical Research Centre, Moorfields Eye Hospital NHS Foundation Trust, London, United Kingdom; UCL Institute of Ophthalmology, London, United Kingdom
| | - Anthony P Khawaja
- National Institute for Health Research Biomedical Research Centre, Moorfields Eye Hospital NHS Foundation Trust, London, United Kingdom; UCL Institute of Ophthalmology, London, United Kingdom
| | - John Gallacher
- Department of Psychiatry, University of Oxford, Oxford, United Kingdom
| | | | - Paul J Foster
- National Institute for Health Research Biomedical Research Centre, Moorfields Eye Hospital NHS Foundation Trust, London, United Kingdom; UCL Institute of Ophthalmology, London, United Kingdom.
| |
Collapse
|