1
|
Lundblad LKA, Blouin N, Grudin O, Grudina L, Drapeau G, Restrepo N, Ducharme FM. Comparing lung oscillometry with a novel, portable flow interrupter device to measure lung mechanics. J Appl Physiol (1985) 2021; 130:933-940. [PMID: 33539262 DOI: 10.1152/japplphysiol.01072.2020] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
Abstract
In the community setting, assessing spirometry in school-aged children is often limited by the unavailability of respirology technicians at the point-of-care. We developed a new technique called the Rapid Expiratory Occlusion Method (REOM) that measures respiratory resistance during normal breathing, without specialized training. The aim was to examine the concordance between respiratory resistance measured with the REOM and respiratory resistance measured by oscillometry on the tremoflo. Children aged 6-17 yr, with or without asthma, received respiratory resistance testing on the tremoflo, then on the REOM. Three to five replicates with a coefficient of variation ≤15% were obtained on each instrument; the primary outcome was the concordance between the average respiratory resistance on the REOM and that measured at 5 Hz (R5) on the tremoflo. Thirty-two children (11 girls; 21 boys) were enrolled with a mean age of 11.2 (range 6-17) yr; after excluding two children not meeting reproducibility criteria, 9 healthy controls, 15 controlled asthmatics, and 6 poorly controlled asthmatics were included. Resistance measured on the REOM showed a strong correlation with R5 measured on the tremoflo (P < 0.0001) with no significant differences on the Bland-Altman analyses. Children and their parents found the REOM easy to use and would consider for home use if recommended by their doctor. With the high concordance between resistance values measured on the REOM and that on the tremoflo combined with perceived ease of use, the REOM appears as a promising means for measuring lung function, thus supporting further testing of other psychometric properties.NEW & NOTEWORTHY We have developed a novel version of the interrupter technique to measure respiratory resistance. The Rapid Expiratory Occlusion Method (REOM) is a small handheld device that measures respiratory resistance and demonstrates excellent correlation with airway oscillometry. With its ease of use, REOM may be promising for use in community practice, patient's homes, and, if paired with a telemedicine application, could enable the healthcare provider to monitor patients in their homes.
Collapse
Affiliation(s)
- Lennart K A Lundblad
- Meakins-Christie Laboratories, McGill University, Montreal, Quebec, Canada.,THORASYS Thoracic Medical Systems Inc., Montreal, Quebec, Canada
| | - Nicolas Blouin
- Clinical Research on Childhood Asthma Research Unit, Research Centre, Sainte-Justine University Health Centre, Montreal, Quebec, Canada
| | - Oleg Grudin
- Spirotech Medical Inc., Montreal, Quebec, Canada
| | - Lyudmila Grudina
- THORASYS Thoracic Medical Systems Inc., Montreal, Quebec, Canada
| | - Guy Drapeau
- THORASYS Thoracic Medical Systems Inc., Montreal, Quebec, Canada
| | - Natalia Restrepo
- THORASYS Thoracic Medical Systems Inc., Montreal, Quebec, Canada
| | - Francine M Ducharme
- Clinical Research on Childhood Asthma Research Unit, Research Centre, Sainte-Justine University Health Centre, Montreal, Quebec, Canada.,Department of Pediatrics, University of Montreal, Montreal, Quebec, Canada.,Depatment of Social and Preventive Medicine, University of Montreal, Montreal, Quebec, Canada
| |
Collapse
|
2
|
Manti S, Parisi GF, Giacchi V, Sciacca P, Tardino L, Cuppari C, Salpietro C, Chikermane A, Leonardi S. Pilot study shows right ventricular diastolic function impairment in young children with obstructive respiratory disease. Acta Paediatr 2019; 108:740-744. [PMID: 30194783 DOI: 10.1111/apa.14574] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/14/2017] [Revised: 08/26/2018] [Accepted: 09/06/2018] [Indexed: 11/29/2022]
Abstract
AIM This study determined cardiovascular impairment in young children with obstructive respiratory disease who were assessed using the opening interrupter technique (RINT). METHODS This pilot study enrolled 41 children who had been referred to pulmonology and allergology specialists at the University of Catania, Italy, from March to July 2017: 23 (mean age 4.13 ± 0.62 years) had chronic coughs and wheezing and 18 controls (mean age 4.27 ± 0.66 years) had obstructive chest disease, but were otherwise healthy. Airway resistance was evaluated using RINT and cardiac function by studying the ejection fraction, pulmonary artery systolic pressure (PASP), tricuspid annular plane systolic excursion and tricuspid flow propagation velocity (TFPV). RESULTS The RINT and PASP values were significantly higher in the patient group when compared to the controls, but the TFPV values were lower. A direct and significant Spearman's correlation coefficient (r) between RINT and PASP values was observed (r = 0.81). We found a significant inverse correlation between RINT and TFPV (r = -0.83), as well as TFPV and PASP (r = -0.78). CONCLUSION This study showed that children with obstructive respiratory diseases had a major risk of cardiovascular impairment. Impaired diastolic function of the right ventricle occurred very early when airway resistance was abnormally increased.
Collapse
Affiliation(s)
- S Manti
- Department of Pediatrics; Unit of Pediatric Genetics and Immunology; University of Messina; Messina Italy
| | - G F Parisi
- Department of Clinical and Experimental Medicine; University of Catania; Catania Italy
| | - V Giacchi
- Department of Clinical and Experimental Medicine; University of Catania; Catania Italy
| | - P Sciacca
- Department of Clinical and Experimental Medicine; University of Catania; Catania Italy
| | - L Tardino
- Department of Clinical and Experimental Medicine; University of Catania; Catania Italy
| | - C Cuppari
- Department of Pediatrics; Unit of Pediatric Genetics and Immunology; University of Messina; Messina Italy
| | - C Salpietro
- Department of Pediatrics; Unit of Pediatric Genetics and Immunology; University of Messina; Messina Italy
| | - A Chikermane
- Heart Unit; Birmingham Children's Hospital; National Health Service Foundation Trust; Birmingham UK
| | - S Leonardi
- Department of Clinical and Experimental Medicine; University of Catania; Catania Italy
| |
Collapse
|
3
|
Fainardi V, Lombardi E. Lung function tests to monitor respiratory disease in preschool children. ACTA BIO-MEDICA : ATENEI PARMENSIS 2018; 89:148-156. [PMID: 29957746 PMCID: PMC6179029 DOI: 10.23750/abm.v89i2.7155] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/03/2018] [Accepted: 04/06/2018] [Indexed: 01/22/2023]
Abstract
Pulmonary function tests are routinely used in the diagnosis and follow-up of respiratory diseases. In preschool children assessment and evaluation of lung function has always been challenging but improved techniques that require only minimal collaboration allowed obtaining reliable and useful results even in this group of patients. In this review we will describe the different techniques used in clinical practice to measure lung function in preschool children.(www.actabiomedica.it)
Collapse
Affiliation(s)
| | - Enrico Lombardi
- Paediatric Pulmonary Unit, "Anna Meyer" Paediatric University Hospital, Florence, Italy.
| |
Collapse
|
4
|
VanDevanter DR, Kahle JS, O’Sullivan AK, Sikirica S, Hodgkins PS. Cystic fibrosis in young children: A review of disease manifestation, progression, and response to early treatment. J Cyst Fibros 2016; 15:147-57. [DOI: 10.1016/j.jcf.2015.09.008] [Citation(s) in RCA: 82] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2015] [Revised: 09/18/2015] [Accepted: 09/21/2015] [Indexed: 12/31/2022]
|