1
|
Diederich LM, Pudszuhn A, Hofmann VM. [Pyroban on New Year's Eve 2020 & 2021 - Analysis of firework-related injuries over the last 12 years]. Laryngorhinootologie 2023; 102:675-684. [PMID: 36882096 DOI: 10.1055/a-2016-8672] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/09/2023]
Abstract
There is an increase of firework-related injuries in Germany at the turn of the year. With regard to hearing, a distinction is made between blast (BT) and explosion trauma (ET). The study examines the prevalence and characteristics of firework-related injuries and the impact of the COVID-19-pandemic pyrotechnic ban on New Year's Eve 2020/21 and 2021/22 compared to the 10-year period prior to the pandemic.A retrospective chart review of all patients who presented themselves with the diagnosis blast trauma (H 83.3) or explosion trauma (T 70.8) at the Charité emergency service in the last 12 years from Dezember 28 to January 5 was performed.276 patients were recorded, 77% of whom were male. 1/3 each were assigned to the age group 10-19 and 20-29 years. 21% of the patients were admitted to the hospital. There was an isolated BT of the ear in 67%, hand injuries in 11%, head injuries in 8% and eye injuries in 4%. 87% had ear involvement with hearing loss; 5% of these with ET.8% of the patients underwent surgical interventions. The treatment of a tympanic membrane perforation was carried out by: 54% splinting, 38% tympanoplasty. Therapy with a glucocorticoid was administered i.v. in 48%. and initiated orally in 20%. Overall, there was a nearly 75% decrease in injuries in 2020 and 2021 compared to the previous 10-year period.The use of fireworks leads to increased utilization of health care resources. The ban on the sale of pyrotechnics as well as the introduction of pyro ban zones in 2020 and 2021 led to a relevant decrease in injuries. 2020 and 2021 were the only years in which there were no injuries in children. The BT of the ear is the most common firework-related injury.
Collapse
Affiliation(s)
- Linda Manuela Diederich
- Klinik für HNO-Heilkunde, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| | - Annett Pudszuhn
- Klinik für HNO-Heilkunde, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| | - Veit Maria Hofmann
- Klinik für HNO-Heilkunde, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| |
Collapse
|
2
|
Sonstrom Malowski K, Gollihugh LH, Malyuk H, Le Prell CG. Auditory changes following firearm noise exposure, a review. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2022; 151:1769. [PMID: 35364940 DOI: 10.1121/10.0009675] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/10/2021] [Accepted: 02/10/2022] [Indexed: 06/14/2023]
Abstract
Firearms produce peak sound pressure levels (peak SPL) between ∼130 and 175 dB peak SPL, creating significant risk of noise-induced hearing loss (NIHL) in those exposed to firearm noise during occupational, recreational, and/or military operations. Noise-induced tinnitus and hearing loss are common in military service members, public safety officers, and hunters/shooters. Given the significant risk of NIHL due to firearm and other noise sources, there is an interest in, and demand for, interventions to prevent and/or treat NIHL in high-risk populations. However, research and clinical trial designs assessing NIHL prevention have varied due to inconsistent data from the literature, specifically with end point definitions, study protocols, and assessment methodologies. This article presents a scoping review of the literature pertaining to auditory changes following firearm noise exposure. Meta-analysis was not possible due to heterogeneity of the study designs. Recommendations regarding audiologic test approach and monitoring of populations at risk for NIHL are presented based on critical review of the existing literature.
Collapse
Affiliation(s)
| | - Lindsay H Gollihugh
- School of Speech-Language Pathology and Audiology, The University of Akron, Akron, Ohio 44325, USA
| | - Heather Malyuk
- School of Speech-Language Pathology and Audiology, The University of Akron, Akron, Ohio 44325, USA
| | - Colleen G Le Prell
- Department of Speech, Language, and Hearing, The University of Texas at Dallas, Richardson, Texas 75080, USA
| |
Collapse
|
3
|
Gaetán S, Muratore J, Maggi AL, Villalobo JP, de los Ángeles Hinalaf M. Hearing and Exposure to Music in Adolescents From Four Schools of Córdoba, Argentina. Am J Audiol 2021; 30:281-294. [PMID: 33909451 DOI: 10.1044/2021_aja-20-00076] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
Purposes The aims of this study are (a) to characterize the hearing of adolescents from four schools of Córdoba, Argentina, through the analysis of conventional and extended high-frequency audiometric thresholds and otoacoustic emissions (OAEs) and (b) to analyze the association between the mentioned hearing tests and exposure to music. Method It was a cross-sectional correlational descriptive study. Hearing thresholds (250-16000 Hz), transient evoked OAEs, and distortion product OAEs were evaluated in 225 adolescents (450 ears) aged 14 and 15 years. The ears were split into two groups: Group 1 had thresholds ≤ 21 dB HL in all frequencies, and Group 2 had thresholds > 21 dB HL in at least one. Exposure to music was evaluated through a questionnaire. Results Statistically significant differences were found in both ears between Groups 1 and 2. A notch at 3000-6000 Hz was noted in both groups. Group 2 showed a progressive threshold increase from 9000 Hz. Amplitude decrease, negative values, absent distortion product OAEs, and transient evoked OAEs were noted even in Group 1. A statistically significant association between Groups 1 and 2 and the presence/absence of OAEs was observed in most frequencies. Ears with moderate or high exposure to music had greater hearing thresholds compared to ears with low exposure at most frequencies; this was more evident in Group 1. Regarding exposure to music and OAEs, no significant differences were found between the exposure categories. Conclusions The findings highlight the value of implementing hearing conservation programs in Argentina, analyzing hearing tests correlated with questionnaires about recreational noise exposure in order to detect vulnerable ears early.
Collapse
Affiliation(s)
- Sara Gaetán
- Center of Research and Transfer in Acoustics (CINTRA), UE CONICET, National Technological University, Córdoba, Argentina
- School of Speech, Language and Audiology, Faculty of Medical Sciences, National University of Córdoba, Argentina
- National Scientific and Technical Research Council (CONICET) at the CINTRA, Córdoba, Argentina
| | - Jimena Muratore
- Center of Research and Transfer in Acoustics (CINTRA), UE CONICET, National Technological University, Córdoba, Argentina
- School of Speech, Language and Audiology, Faculty of Medical Sciences, National University of Córdoba, Argentina
- National Scientific and Technical Research Council (CONICET) at the CINTRA, Córdoba, Argentina
- School of Speech, Language and Audiology, Faculty of Medical Sciences, National University of Rosario, Argentina
| | - Ana Luz Maggi
- Center of Research and Transfer in Acoustics (CINTRA), UE CONICET, National Technological University, Córdoba, Argentina
- School of Speech, Language and Audiology, Faculty of Medical Sciences, National University of Córdoba, Argentina
- National Scientific and Technical Research Council (CONICET) at the CINTRA, Córdoba, Argentina
| | - Jorge Pérez Villalobo
- Center of Research and Transfer in Acoustics (CINTRA), UE CONICET, National Technological University, Córdoba, Argentina
| | - María de los Ángeles Hinalaf
- Center of Research and Transfer in Acoustics (CINTRA), UE CONICET, National Technological University, Córdoba, Argentina
- School of Speech, Language and Audiology, Faculty of Medical Sciences, National University of Córdoba, Argentina
| |
Collapse
|
4
|
Prevalence of Hearing Loss Among a Representative Sample of Canadian Children and Adolescents, 3 to 19 Years of Age. Ear Hear 2018; 38:7-20. [PMID: 27556530 PMCID: PMC5181131 DOI: 10.1097/aud.0000000000000345] [Citation(s) in RCA: 51] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/04/2022]
Abstract
Supplemental Digital Content is available in the text. Objectives: There are no nationally representative hearing loss (HL) prevalence data available for Canadian youth using direct measurements. The present study objectives were to estimate national prevalence of HL using audiometric pure-tone thresholds (0.5 to 8 kHz) and or distortion product otoacoustic emissions (DPOAEs) for children and adolescents, aged 3 to 19 years. Design: This cross-sectional population-based study presents findings from the 2012/2013 Canadian Health Measures Survey, entailing an in-person household interview and hearing measurements conducted in a mobile examination clinic. The initial study sample included 2591 participants, aged 3 to 19 years, representing 6.5 million Canadians (3.3 million males). After exclusions, subsamples consisted of 2434 participants, aged 3 to 19 years and 1879 participants, aged 6 to 19 years, with valid audiometric results. Eligible participants underwent otoscopic examination, tympanometry, DPOAE, and audiometry. HL was defined as a pure-tone average >20 dB for 6- to 18-year olds and ≥26 dB for 19-year olds, for one or more of the following: four-frequency (0.5, 1, 2, and 4 kHz) pure-tone average, high-frequency (3, 4, 6, and 8 kHz) pure-tone average, and low-frequency (0.5, 1, and 2 kHz) pure-tone average. Mild HL was defined as >20 to 40 dB (6- to 18-year olds) and ≥26 to 40 dB (19-year olds). Moderate or worse HL was defined as >40 dB (6- to 19-year olds). HL in 3- to 5-year olds (n = 555) was defined as absent DPOAEs as audiometry was not conducted. Self-reported HL was evaluated using the Health Utilities Index Mark 3 hearing questions. Results: The primary study outcome indicates that 7.7% of Canadian youth, aged 6 to 19, had any HL, for one or more pure-tone average. Four-frequency pure-tone average and high-frequency pure-tone average HL prevalence was 4.7 and 6.0%, respectively, whereas 5.8% had a low-frequency pure-tone average HL. Significantly more children/adolescents had unilateral HL. Mild HL was significantly more common than moderate or worse HL for each pure-tone average. Among Canadians, aged 6 to 19, less than 2.2% had sensorineural HL. Among Canadians, aged 3 to 19, less than 3.5% had conductive HL. Absent DPOAEs were found in 7.1E% of 3- to 5-year olds, and in 3.4E% of 6- to 19-year olds. Among participants eligible for the hearing evaluation and excluding missing data cases (n = 2575), 17.0% had excessive or impacted pus/wax in one or both ears. Self-reported HL in Canadians, aged 6 to 19, was 0.6 E% and 65.3% (aged 3 to 19) reported never having had their hearing tested. E indicates that a high sampling variability is associated with the estimate (coefficient of variation between 16.6% and 33.3%) and should be interpreted with caution. Conclusions: This study provides the first estimates of audiometrically measured HL prevalence among Canadian children and adolescents. A larger proportion of youth have measured HL than was previously reported using self-report surveys, indicating that screening using self-report or proxy may not be effective in identifying individuals with mild HL. Results may underestimate the true prevalence of HL due to the large number excluded and the presentation of impacted or excessive earwax or pus, precluding an accurate or complete hearing evaluation. The majority of 3- to 5-year olds with absent DPOAEs likely had conductive HL. Nonetheless, this type of HL which can be asymptomatic, may become permanent if left untreated. Future research will benefit from analyses, which includes the slight HL category, for which there is growing support, and from studies that identify factors contributing to HL in this population.
Collapse
|
5
|
Hoth S, Baljić I. Current audiological diagnostics. GMS CURRENT TOPICS IN OTORHINOLARYNGOLOGY, HEAD AND NECK SURGERY 2017; 16:Doc09. [PMID: 29279727 PMCID: PMC5738938 DOI: 10.3205/cto000148] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Today's audiological functional diagnostics is based on a variety of hearing tests, whose large number takes account of the variety of malfunctions of a complex sensory organ system and the necessity to examine it in a differentiated manner and at any age of life. The objective is to identify nature and origin of the hearing loss and to quantify its extent as far as necessary to dispose of the information needed to initiate the adequate medical (conservative or operational) treatment or the provision with technical hearing aids or prostheses. Moreover, audiometry provides the basis for the assessment of impairment and handicap as well as for the calculation of the degree of disability. In the present overview, the current state of the method inventory available for practical use is described, starting from basic diagnostics over to complex special techniques. The presentation is systematically grouped in subjective procedures, based on psychoacoustic exploration, and objective methods, based on physical measurements: preliminary hearing tests, pure tone threshold, suprathreshold processing of sound intensity, directional hearing, speech understanding in quiet and in noise, dichotic hearing, tympanogram, acoustic reflex, otoacoustic emissions and auditory evoked potentials. Apart from a few still existing gaps, this method inventory covers the whole spectrum of all clinically relevant functional deficits of the auditory system.
Collapse
Affiliation(s)
- Sebastian Hoth
- Functional Area of Audiology, Department of Otolaryngology, University of Heidelberg, Germany
| | - Izet Baljić
- Department of Otolaryngology, HELIOS Hospital of Erfurt, Germany
| |
Collapse
|
6
|
Feder K, Michaud D, McNamee J, Fitzpatrick E, Davies H, Leroux T. Prevalence of Hazardous Occupational Noise Exposure, Hearing Loss, and Hearing Protection Usage Among a Representative Sample of Working Canadians. J Occup Environ Med 2017; 59:92-113. [PMID: 28045804 PMCID: PMC5704673 DOI: 10.1097/jom.0000000000000920] [Citation(s) in RCA: 54] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
OBJECTIVE The aim of this study was to estimate the prevalence of hearing loss (HL), self-reported occupational noise exposure, and hearing protection usage among Canadians. METHODS In-person household interviews were conducted with 3666 participants, aged 16 to 79 years (1811 males) with 94% completing audiometry and distortion-product otoacoustic emission (DPOAE) evaluations. Occupational noise exposure was defined as hazardous when communicating with coworkers at an arm's length distance required speaking in a raised voice. RESULTS An estimated 42% of respondents reported hazardous occupational noise exposure; 10 years or more was associated with HL regardless of age, sex or education. Absent DPOAEs, tinnitus, and the Wilson audiometric notch were significantly more prevalent in hazardous workplace noise-exposed workers than in nonexposed. When mandatory, 80% reported wearing hearing protection. CONCLUSIONS These findings are consistent with other industrialized countries, underscoring the need for ongoing awareness of noise-induced occupational HL.
Collapse
Affiliation(s)
- Katya Feder
- Health Effects and Assessment Division, Health Canada (Drs Feder, Michaud, McNamee), Audiology & Speech-language Pathology Program, Faculty of Health Sciences, University of Ottawa, Ottawa, Ontario (Dr Fitzpatrick), Occupational & Environmental Health, School of Population & Public Health, University of British Columbia, Vancouver, British Columbia (Dr Davies), and École d'orthophonie et d'audiologie, Université de Montréal, Faculté de médecine, Montréal, Québec, Canada (Dr Leroux)
| | | | | | | | | | | |
Collapse
|
7
|
Trzaskowski B, Pilka E, Jedrzejczak WW, Skarzynski H. Criteria for detection of transiently evoked otoacoustic emissions in schoolchildren. Int J Pediatr Otorhinolaryngol 2015; 79:1455-61. [PMID: 26166450 DOI: 10.1016/j.ijporl.2015.06.028] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/01/2015] [Revised: 06/08/2015] [Accepted: 06/20/2015] [Indexed: 11/30/2022]
Abstract
OBJECTIVES The aim was to compare, on the same dataset, existing detection criteria for transiently evoked otoacoustic emissions (TEOAEs) and to select those most suitable for use with school-aged children. METHODS TEOAEs were recorded from the ears of 187 schoolchildren (age 8-10 years) using the Otodynamics ILO 292 system with a standard click stimulus of 80dB peSPL. Pure tone audiometry and tympanometry were also conducted. Global and half-octave-band (at 1, 1.4, 2, 2.8, 4kHz) values of OAE signal-to-noise ratio (SNR), reproducibility, and response level were determined. These parameters were used as criteria for detection of TEOAEs. In total, 21 criteria based on the literature and 3 new ones suggested by the authors were investigated. RESULTS Pure tone audiometry and tympanometry screening generated an ear-based failure rate of 7.49%. For TEOAEs, there was a huge variability in failure rate depending on the criteria used. However, three criteria sets produced simultaneous values of sensitivity and specificity above 75%. The first of these criteria was based only on a global reproducibility threshold value above 50%; the second on certain global reproducibility and global response values; and the third involved exceeding a threshold of 50% band reproducibility. The two criteria sets with the best sensitivity were based on global reproducibility, response level, and signal-to-noise ratio (with different thresholds across frequency bands). CONCLUSIONS TEAOEs can be efficiently used to test the hearing of schoolchildren provided appropriate protocols and criteria sets are used. They are quick, repeatable, and simple to perform, even for nonaudiologically trained personnel. Criteria with high sensitivity (89%) were identified, but they had relatively high referral rates. This is not so much a problem in schoolchildren as it is in newborns because with schoolchildren pure tone audiometry and tympanometry can be performed immediately or at a follow-up session. Nevertheless, high referral rates lead to increased screening cost; for that reason, three less rigorous criteria with high values of both sensitivity and specificity (75% and above) are recommended.
Collapse
Affiliation(s)
- Bartosz Trzaskowski
- Institute of Physiology and Pathology of Hearing, Mochnackiego 10, 02-042 Warsaw, Poland; World Hearing Center, Mokra 17 Street, Kajetany, 05-830 Nadarzyn, Poland.
| | - Edyta Pilka
- Institute of Physiology and Pathology of Hearing, Mochnackiego 10, 02-042 Warsaw, Poland; World Hearing Center, Mokra 17 Street, Kajetany, 05-830 Nadarzyn, Poland.
| | - W Wiktor Jedrzejczak
- Institute of Physiology and Pathology of Hearing, Mochnackiego 10, 02-042 Warsaw, Poland; World Hearing Center, Mokra 17 Street, Kajetany, 05-830 Nadarzyn, Poland.
| | - Henryk Skarzynski
- Institute of Physiology and Pathology of Hearing, Mochnackiego 10, 02-042 Warsaw, Poland; World Hearing Center, Mokra 17 Street, Kajetany, 05-830 Nadarzyn, Poland.
| |
Collapse
|
8
|
Trzaskowski B, Jędrzejczak WW, Piłka E, Cieślicka M, Skarżyński H. Otoacoustic emissions before and after listening to music on a personal player. Med Sci Monit 2014; 20:1426-31. [PMID: 25116920 PMCID: PMC4140723 DOI: 10.12659/msm.890747] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
Background The problem of the potential impact of personal music players on the auditory system remains an open question. The purpose of the present study was to investigate, by means of otoacoustic emissions (OAEs), whether listening to music on a personal player affected auditory function. Material/Methods A group of 20 normally hearing adults was exposed to music played on a personal player. Transient evoked OAEs (TEOAEs) and distortion product OAEs (DPOAEs), as well as pure tone audiometry (PTA) thresholds, were tested at 3 stages: before, immediately after, and the next day following 30 min of exposure to music at 86.6 dBA. Results We found no statistically significant changes in OAE parameters or PTA thresholds due to listening to the music. Conclusions These results suggest that exposure to music at levels similar to those used in our study does not disturb cochlear function in a way that can be detected by means of PTA, TEOAE, or DPOAE tests.
Collapse
Affiliation(s)
- Bartosz Trzaskowski
- Department of Experimental Audiology, World Hearing Center, Institute of Physiology and Pathology of Hearing, Warsaw/Kajetany, Poland
| | - W Wiktor Jędrzejczak
- Department of Experimental Audiology, World Hearing Center, Institute of Physiology and Pathology of Hearing, Warsaw/Kajetany, Poland
| | - Edyta Piłka
- Department of Experimental Audiology, World Hearing Center, Institute of Physiology and Pathology of Hearing, Warsaw/Kajetany, Poland
| | - Magdalena Cieślicka
- Faculty of Electronics and Information Technology, Warsaw University of Technology, Warsaw, Poland
| | - Henryk Skarżyński
- World Hearing Center, Institute of Physiology and Pathology of Hearing, Warsaw/Kajetany, Poland
| |
Collapse
|
9
|
Mehrparvar AH, Mirmohammadi SJ, Davari MH, Mostaghaci M, Mollasadeghi A, Bahaloo M, Hashemi SH. Conventional Audiometry, Extended High-Frequency Audiometry, and DPOAE for Early Diagnosis of NIHL. IRANIAN RED CRESCENT MEDICAL JOURNAL 2014; 16:e9628. [PMID: 24719719 PMCID: PMC3964437 DOI: 10.5812/ircmj.9628] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/13/2012] [Revised: 11/19/2013] [Accepted: 05/13/2013] [Indexed: 12/11/2022]
Abstract
Background: Noise most frequently affects hearing system, as it may typically cause a bilateral, progressive sensorineural hearing loss at high frequencies. Objectives: This study was designed to compare three different methods to evaluate noise-induced hearing loss (conventional audiometry, high-frequency audiometry, and distortion product otoacoustic emission). Material and Methods: This was a cross-sectional study. Data was analyzed by SPSS (ver. 19) using chi square, T test and repeated measures analysis. Study samples were workers from tile and ceramic industry. Results: We found that conventional audiometry, extended high-frequency audiometry, low-tone distortion product otoacoustic emission and high-tone distortion product otoacoustic emission had abnormal findings in 29 %, 69 %, 22 %, and 52 % of participants. Most frequently affected frequencies were 4000 and 6000Hz in conventional audiometry, and 14000 and 16000 in extended high-frequency audiometry. Conclusions: Extended high-frequency audiometry was the most sensitive test for detection of hearing loss in workers exposed to hazardous noise compared with conventional audiometry and distortion product otoacoustic.
Collapse
Affiliation(s)
- Amir Houshang Mehrparvar
- Department of Occupational Medicine, Shahid Sadoughi University of Medical Sciences, Yazd, IR Iran
| | | | - Mohammad Hossein Davari
- Department of Occupational Medicine, Shahid Sadoughi University of Medical Sciences, Yazd, IR Iran
- Corresponding Author: Mohammad Hossein Davari, Shahid Rahnamoun Hospital, Farrokhi Ave, Yazd, IR Iran. Tel: +98-3516629193, Fax: +98-3156629194, E-mail:
| | - Mehrdad Mostaghaci
- Department of Occupational Medicine, Shahid Sadoughi University of Medical Sciences, Yazd, IR Iran
| | - Abolfazl Mollasadeghi
- Industrial Diseases Research Center, Shahid Sadoughi University of Medical Sciences, Yazd, IR Iran
| | - Maryam Bahaloo
- Industrial Diseases Research Center, Shahid Sadoughi University of Medical Sciences, Yazd, IR Iran
| | - Seyyed Hesam Hashemi
- Department of Occupational Medicine, Shahid Sadoughi University of Medical Sciences, Yazd, IR Iran
| |
Collapse
|
10
|
Tringali S, Perrot X, Collet L, Moulin A. Exposition sonore et répercussions auditives au cours de la stimulation magnétique transcrânienne répétitive : données récentes et revue de la littérature. Neurophysiol Clin 2013; 43:19-33. [DOI: 10.1016/j.neucli.2012.07.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2011] [Revised: 04/16/2012] [Accepted: 07/07/2012] [Indexed: 12/12/2022] Open
|
11
|
Psaltakos V, Balatsouras DG, Sengas I, Ferekidis E, Riga M, Korres SG. Cochlear dysfunction in patients with acute hypothyroidism. Eur Arch Otorhinolaryngol 2012; 270:2839-48. [PMID: 23266870 DOI: 10.1007/s00405-012-2332-9] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2012] [Accepted: 12/13/2012] [Indexed: 12/26/2022]
Abstract
The effect of acute hypothyroidism on the cochlear function was studied prospectively, in a group of 52 patients with thyroid carcinoma who underwent total thyroidectomy. All patients were examined before surgery and 6-8 weeks postoperatively. During this period there was no replacement with levothyroxine and the magnitude of thyroxin depletion was monitored by serum thyroid-stimulating hormone levels. Pure-tone audiometry, tympanometry and transiently evoked otoacoustic emissions were performed. A group of healthy volunteers of similar age and sex were used as controls. Tympanograms were normal, either on initial or on repeat testing. Audiometry showed elevation of all postoperative hearing thresholds, whereas the thresholds varied significantly across frequency. Transiently evoked otoacoustic emission testing showed response signal-to-noise ratios lower in the postoperative session (hypothyroid state) than in the preoperative session on all measured frequencies. Emission levels varied significantly across frequency, with maximum response observed at 2 kHz. Comparison of significant pure-tone and otoacoustic emission shifts for individual ears showed more ears affected in otoacoustic emission testing, indicating subclinical involvement. Comparing hearing thresholds and otoacoustic emission levels between patients and controls showed significant differences on postoperative testing. It may be thus concluded that acute hypothyroidism causes elevation of hearing thresholds in humans and to a greater degree subclinical damage of the cochlear function.
Collapse
Affiliation(s)
- Vassilis Psaltakos
- Ear, Nose and Throat Department, Tzanion General Hospital, Piraeus, Greece
| | | | | | | | | | | |
Collapse
|
12
|
Extended Frequency Range Hearing Thresholds and Otoacoustic Emissions in Acute Acoustic Trauma. Otol Neurotol 2012; 33:1315-22. [DOI: 10.1097/mao.0b013e318263d598] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
13
|
Abstract
In recent decades, acoustic shock and explosion traumas have increased in frequency in the general population. Beside the use of fireworks and firearms, airbag ignitions and explosions caused by terror or suicidal acts are also relevant. Depending on duration and strength of the sound pressure affecting the human ear, isolated inner ear damage or additional ear drum perforation and interruption of the middle ear ossicle chain can result. By means of otoscopy, pure tone audiometry, measurement of otoacoustic emissions, and other neurootological examinations, the severity of the trauma can be determined. With prompt and adequate therapy, permanent hearing loss can be minimized. In particular, the measurement of otoacoustic emissions allows conclusions to be made on the functionality of the outer hair cells which are damaged first in most cases. Histological investigations on noise-exposed cochleas show extensive damage to the outer hair cells in the frequency range between 1.0 and 4.0 kHz, which correlates well with audiometric measurements.
Collapse
Affiliation(s)
- P S van de Weyer
- HNO-Universitätsklinik Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg, Deutschland.
| | | | | |
Collapse
|
14
|
Cochlear dysfunction in hyperuricemia: otoacoustic emission analysis. Am J Otolaryngol 2010; 31:154-61. [PMID: 20015733 DOI: 10.1016/j.amjoto.2008.12.002] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2008] [Revised: 12/03/2008] [Accepted: 12/08/2008] [Indexed: 12/22/2022]
Abstract
PURPOSE The objective of this study is to provide evidence that primary hyperuricemia is associated with cochlear dysfunction as other metabolic diseases that interfere with cell metabolism. MATERIALS AND METHODS Cochlear function was evaluated in 25 subjects with asymptomatic hyperuricemia using routine diagnostic audiometry along with transient evoked and distortion product otoacoustic emissions (TEOAE and DPOAE, respectively). To support the notion that vascular compromise was a significant underlying factor for such cochlear dysfunction, we assessed vascular anatomical and functional states through measuring the common carotid artery intima-media thickness and flow velocity of the basal intracranial vessels. RESULTS Compared with control subjects, reduced response levels of TEOAEs (P < .01) and amplitudes of DPOAEs (P < .001) were detected at higher frequencies. The reduced DPOAE levels at 5 kHz and TEOAEs at 4 kHz correlated significantly with uric acid (P < .05; P < .01), patients' age (P < .06; P < .05), duration since diagnosis of hyperuricemia (P < .05; P < .001), common carotid artery intima-media thickness (P < .05), mean flow velocities of middle cerebral arteries (P < .05), and vertebral arteries (P < .01). Multivariate analysis showed that the abnormalities at higher frequencies were significantly correlated with the duration and degree of hyperuricemia. CONCLUSIONS These data suggest that subclinical changes in cochlear function are associated with hyperuricemia. They support the usefulness of otoacoustic emissions in early detection of cochlear dysfunction. It is possible that hyperuricemia could be accompanied by increased stiffness and/or compromise of blood supply of the outer hair cells, which will impair their electromotile response.
Collapse
|
15
|
Hoth S, Gudmundsdottir K, Plinkert P. Age dependence of otoacoustic emissions: the loss of amplitude is primarily caused by age-related hearing loss and not by aging alone. Eur Arch Otorhinolaryngol 2009; 267:679-90. [DOI: 10.1007/s00405-009-1106-5] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2008] [Accepted: 09/11/2009] [Indexed: 10/20/2022]
|
16
|
Balatsouras DG, Tsimpiris N, Korres S, Karapantzos I, Papadimitriou N, Danielidis V. The effect of impulse noise on distortion product otoacoustic emissions. Int J Audiol 2009; 44:540-9. [PMID: 16238185 DOI: 10.1080/14992020500190201] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
The aim of this study was the evaluation of distortion product otoacoustic emissions (DPOAEs) before and after noise exposure from shooting, and the comparison of DPOAEs with pure-tone audiometry. Thirteen young male police officers were exposed to impulse noise from shooting, without using earplugs. Standard pure-tone audiometry, tympanometry, and DPOAEs were performed before exposure and at one hour post- and 24 hour post-exposure. In the one hour post-exposure testing mean pure-tone thresholds were elevated in the 1-8 kHz frequency zone and DPOAE levels were reduced at several frequencies. DPOAEs were more affected at 3 kHz or lower, whereas pure-tone thresholds were more affected at higher frequencies. After the final examination, non-significant partial shifts at high frequencies on both tests remained. Pure-tone audiometry was overall more sensitive, but DPOAEs provided additional information about the cochlear status of certain ears. These data suggest that besides behavioral testing, DPOAEs may play a role as a fast, objective, and easy to perform test for monitoring subjects exposed to impulse noise.
Collapse
|
17
|
Bockstael A, Keppler H, Dhooge I, D'haenens W, Maes L, Philips B, Vinck B. Effectiveness of hearing protector devices in impulse noise verified with transiently evoked and distortion product otoacoustic emissions. Int J Audiol 2009; 47:119-33. [DOI: 10.1080/14992020701704784] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
18
|
Bhagat SP, Davis AM. Modification of otoacoustic emissions following ear-level exposure to MP3 player music. Int J Audiol 2009; 47:751-60. [DOI: 10.1080/14992020802310879] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
19
|
Bhagat S. Analysis of distortion product otoacoustic emission spectra in normal-hearing adults. Am J Audiol 2009; 18:60-8. [PMID: 19307288 DOI: 10.1044/1059-0889(2009/08-0025)] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
PURPOSE To evaluate the ability of distortion product otoacoustic emission (DPOAE) spectral characteristics to distinguish between ears with variable hearing sensitivity within the normal range. METHOD Distortion product grams (DP-grams) were acquired with primary tones decremented in 1/8-octave steps and primary-tone levels presented at 65 dB SPL (L1) and 45 dB SPL (L2) across an f2 frequency range of 842-7996 Hz from 22 normal-hearing adults (44 ears). Hearing thresholds of ears classified in Group A (n = 22) were better than ears classified in Group B (n = 22). Examined parameters of the DP-grams included spectral peak occurrence, peak height, peak width, and DPOAE levels. Analyses of variance were conducted to determine whether DP-gram parameters differed between Group A and Group B. RESULTS For the low-resolution DP-grams examined in this study, no significant between-group differences in peak occurrence, peak height, and peak width were observed. DPOAE levels were significantly higher in ears classified in Group A compared with ears classified in Group B in individuals with symmetrical hearing. CONCLUSIONS Although spectral peaks are evident in DP-grams acquired with low resolution of the primary tones, DPOAE levels are more effective in distinguishing ears with greater hearing sensitivity from less sensitive ears.
Collapse
|
20
|
Occupational styrene exposure and hearing loss: a cohort study with repeated measurements. Int Arch Occup Environ Health 2008; 82:463-80. [PMID: 18762967 DOI: 10.1007/s00420-008-0355-8] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2008] [Accepted: 08/11/2008] [Indexed: 10/21/2022]
Abstract
OBJECTIVE Associations between occupational styrene exposure and impairment of hearing function were investigated, guided by three questions: are there hearing losses concerning high frequency and standard audiometric test? Are there dose-response relationships and measurable thresholds of effects? Are there signs of reversibility of possible effects if the workers are examined during times of improvement from their work? METHODS A group of workers from a boat building plant, some of whom were laminators, were examined in subgroups of current low (n = 99, mean mandelic acid MA + phenylglyoxylic acid PGA = 51 mg/g creatinine), medium (n = 118, mean 229 mg/g creat.) and high (n = 31, mean 970 mg/g creat.) exposure to styrene. In addition, subgroups chronically exposed to high-long (n = 17) and low-short (n = 34) styrene levels were analysed. The examinations were carried out during normal work days and during the company holidays. Hearing thresholds and transient evoked otoacoustic emissions (TEOAE) were measured. Statistics included multiple co-variance analyses with repeated measures, linear regressions, and logistic regressions. RESULTS The analyses of all participants demonstrated no clear exposure effects. Particularly no sufficient proof of dose-response relationship measured against parameters of current exposure (MA + PGA, styrene/blood) and of chronic exposure (cumulative and average life time exposure resp.) was found. The analyses of groups exposed to high levels show elevated thresholds at frequencies up to 1,500 Hz among the subgroup exposed to high styrene levels (e.g. 40-50 ppm as average) for a longer period of time (e.g. more than 10 years). These participants also demonstrated signs of "improvement" at frequencies above 2,000 Hz during work holidays, when they were not exposed to styrene. A significantly elevated odds ratio for cases of hearing loss (more than 25 dB (A) in one ear, 3,000-6,000 Hz) was found among the group exposed to high levels (above 30 ppm as average) for a longer period of time (more than 10-26 years). The measurements of TEOAE did not exhibit significant results related to exposure. CONCLUSION This study found, that chronic and intensive styrene exposure increases the hearing thresholds. At levels of about 30-50 ppm as an average inhaled styrene per work day over a period of about 15 years with higher exposure levels above 50 ppm in the past, an elevated risk for impaired hearing thresholds can be expected. The formerly published results on ototoxic effects below 20 ppm could not be confirmed. With few exceptions (at frequencies of 1,000 and 1,500 Hz) no dose-response relationship between threshold and exposure data was found. Improvements of hearing thresholds during work- and exposure-free period are possible.
Collapse
|
21
|
Shupak A, Tal D, Sharoni Z, Oren M, Ravid A, Pratt H. Otoacoustic Emissions in Early Noise-Induced Hearing Loss. Otol Neurotol 2007; 28:745-52. [PMID: 17721363 DOI: 10.1097/mao.0b013e3180a726c9] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVE To follow changes in transient evoked and distortion product otoacoustic emissions (TEOAEs, DPOAEs) as they relate to pure-tone audiometry (PTaud) thresholds during the first 2 years of occupational noise exposure. DESIGN Prospective controlled. METHODS Pure-tone audiometry thresholds, TEOAE and DPOAE amplitudes, and contralateral medial olivocochlear reflex strength were repeatedly evaluated during 2 years and compared between and within a cohort of 135 ship engine room recruits and a control group of 100 subjects with no noise exposure. RESULTS Pure-tone audiometry thresholds for 2,000, 3,000 and 4,000 Hz in both ears were significantly elevated in the study group after 2 years of noise exposure. Significantly lower TEOAE amplitudes were found at 2,000 Hz in the right ear and 2,000 and 4,000 Hz in the left ear. Longitudinal intrasubject analysis of the study group revealed significant reductions of TEOAE amplitudes at 2,000 to 4,000 Hz in both ears and reduced DPOAE amplitudes for 5,957 Hz in the right ear and 3,809, 4,736, and 5,957 Hz in the left ear in the second follow-up evaluation. Baseline medial olivocochlear reflex strength showed no correlation to PTaud thresholds after 2 years of noise exposure. Poor to moderate negative linear correlations (r = -0.07 to -0.37) were found between the DPOAE-averaged amplitudes at 2,979 to 5,957 Hz and PTaud threshold means at 3,000 to 6,000 Hz. Abnormal TEOAE parameters after the first year of noise exposure had high sensitivity (86-88%) and low specificity (33-35%) for the prediction of noise-induced hearing loss (NIHL) after 2 years. CONCLUSION The DP-gram is not significantly correlated with PTaud and cannot be used as an objective measure of pure-tone thresholds in early NIHL. Medial olivocochlear reflex strength before the beginning of chronic exposure to occupational noise has no relation to individual vulnerability to NIHL. Although TEOAEs changes after 1 year showed high sensitivity in predicting NIHL after 2 years of exposure, they cannot be recommended as an efficient screening tool due to high false-positive rates.
Collapse
Affiliation(s)
- Avi Shupak
- Unit of Otoneurology, Carmel and Lin Medical Centre, Haifa, Israel.
| | | | | | | | | | | |
Collapse
|
22
|
Duvdevany A, Furst M. Immediate and long-term effect of rifle blast noise on transient-evoked otoacoustic emissions. J Basic Clin Physiol Pharmacol 2007; 17:173-85. [PMID: 17598308 DOI: 10.1515/jbcpp.2006.17.3.173] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Firing noise of small-arms is characterized by a rapid change in pressure and a sharp peak in sound pressure level of 155-170 dB SPL. In the present study, we examined the behavior of transient-evoked otoacoustic emissions (TEOAE) of a group of soldiers exposed initially to the noise of small-arms fire during their basic training. The study included 15 soldiers and lasted 6 months. Measurements were performed before and immediately after two firing sessions, 2 weeks apart, and after 6 months. There was no significant difference between the audiograms that were measured prior to the noise exposure and those measured after 6 months. Wide-band TEOAE levels decreased over time, but the most significant decrease occurred between the two last sessions that were 5.5 months apart. No significant changes in TEOAE levels were observed before and immediately after exposure. However, at the high frequency range, an increase in TEOAE levels was observed in the third session relative to the previous one. During the 2 weeks after the first exposure, the soldiers were not exposed to noise. This TEOAE property might indicate the existence of a protective mechanism in the ear from traumatic harmful noise.
Collapse
Affiliation(s)
- Amnon Duvdevany
- Acoustics & Electromagnetic Radiation Section, Occupational Health Branch, Medical Corps, Israel Defense Forces, Israel
| | | |
Collapse
|
23
|
Rosanowski F, Eysholdt U, Hoppe U. Influence of leisure-time noise on outer hair cell activity in medical students. Int Arch Occup Environ Health 2006; 80:25-31. [PMID: 16506044 DOI: 10.1007/s00420-006-0090-y] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2005] [Accepted: 01/23/2006] [Indexed: 11/28/2022]
Abstract
OBJECTIVE Noise exceeding a certain level can damage outer hair cells and thus cause hearing loss. In the past, noise-induced hearing loss was mainly caused by occupational noise. Leisure-time noise may be a promoting factor, particularly in young adults. The purpose of this study was to investigate whether transient evoked otoacoustic emissions (TEOAE) can be used to evaluate outer hair cell damage in young adults with no history of hearing complaints. The data obtained from the measurement of TEOAE were correlated with the participants' listening habits and exposure to leisure-time noise. METHODS Eighty-eight young adults (47 women, 41 men; age 22.9+/-2.9 years) were examined. TEOAE were measured using standard ILO 88 equipment. All participants had normal hearing (hearing thresholds better than 20 dB HL; frequency range 0.125-10 kHz). None of the participants suffered from permanent tinnitus. All participants answered a questionnaire concerning their listening habits. RESULTS On average, the participants frequented a discotheque 1.4 times a month; 25% had never visited a discotheque, 35% visited once a month and 32% twice or three times a month. Sixteen per cent reported transient tinnitus after every visit to a discotheque and 58% after nearly every visit. Eight per cent suffered from transient hearing loss after every visit to a disco and 37% after nearly every visit. Three per cent (4%) reported tinnitus (nearly) every morning after visiting a discotheque. The TEOAE level was above 6 dB in all participants [9.2+/-3.6 dB (mean +/- SD)] and reproducibility was above 60% (90+/-9%). All values matched pass criteria for normal TEOAE under clinical conditions. However, TEOAE levels and reproducibility decreased significantly with an increased number of visits to discotheques. CONCLUSION Outer hair cell damage could be measured using TEOAE in individuals exposed to leisure-time noise, although these individuals exhibited no measurable puretone hearing loss.
Collapse
Affiliation(s)
- Frank Rosanowski
- Department of Phoniatrics and Pediatric Audiology, Erlangen University Hospital, Erlangen, Germany
| | | | | |
Collapse
|
24
|
Wagner W, Heppelmann G, Kuehn M, Tisch M, Vonthein R, Zenner HP. Olivocochlear activity and temporary threshold shift-susceptibility in humans. Laryngoscope 2006; 115:2021-8. [PMID: 16319617 DOI: 10.1097/01.mlg.0000181463.16591.a7] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
STUDY OBJECTIVES Animal studies (guinea pig, cat, chinchilla) have shown that activity of the medial olivocochlear efferents can exert noise-protective effects on the cochlea. It is not yet known whether such effects are also existent in humans. Olivocochlear activity can be estimated indirectly by contralateral suppression (CS) of otoacoustic emissions (OAE). MATERIAL AND METHODS We measured Input/Output functions of distortion products of OAE (DPOAE), with and without contralateral acoustic stimulation by white noise, in 94 normal hearing young male subjects. Seven stimuli with L2 between 20 and 60 dB SPL and L1 = 39 dB + 0.4 L2 ("scissor paradigm") were used at f2 = 2, 3, 4, 5, and 6 kHz. The measurement was repeated 2 weeks later. In 83 subjects of the same group, pure tone audiometry was registered before and 6 minutes after shooting exercises to evaluate individual susceptibility to develop a temporary threshold shift (TTS). RESULTS Test-retest repeatability of CS was generally good. CS averaged 0.98 dB SPL (SD 1.19 dB, median 0.56 dB). As expected, CS was greatest at low stimulus levels (median 1.06 dB at L2 = 20 dB, as compared with 0.33 dB at L2 = 60 dB). The smallest average CS was found at 4 kHz, and the greatest CS appeared at 2 kHz. A TTS occurred in 7 of 83 (8.5%) subjects. Statistical analysis did not reveal any correlation between the amount of CS and individual TTS susceptibility. CONCLUSIONS AND OUTLOOK 1) Measurement of CS of DPOAE using an extensive measurement paradigm revealed good test-retest repeatability, confirming the reliability of this audiologic tool. 2) CS of DPOAE does not predict individual susceptibility to mild TTS induced by impulse noise in humans. Possible explanations for the missing association are discussed. Future perspectives include longitudinal studies to further elucidate the association between medial olivocochlear bundle-activity and permanent threshold shift in humans. The goal is to develop a diagnostic tool for the prediction of individual noise vulnerability in humans, thereby preventing noise-induced hearing loss.
Collapse
Affiliation(s)
- W Wagner
- Department of Otorhinolaryngology, University of Tuebingen, Tuebingen, Germany.
| | | | | | | | | | | |
Collapse
|
25
|
Wagner W, Staud I, Frank G, Dammann F, Plontke S, Plinkert PK. Noise in magnetic resonance imaging: no risk for sensorineural function but increased amplitude variability of otoacoustic emissions. Laryngoscope 2003; 113:1216-23. [PMID: 12838022 DOI: 10.1097/00005537-200307000-00020] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES Objectives were to perform exact measurements of the noise exposure in a magnetic resonance imager and to investigate the effects of magnetic resonance imaging (MRI) noise on hearing sensitivity, which are still controversial, in a large number of patients. STUDY DESIGN Prospective trial. METHODS Acoustic noise during seven different MRI sequences was measured using a custom-made microphone containing no ferromagnetic parts. In 244 ears of 126 patients, pure-tone audiometry was performed once before and once after MRI noise, and distortion product otoacoustic emissions were measured once before and three times after MRI. RESULTS The sound pressure level (SPL) at the patient's ear (with consideration of the sound-damping effect of the head support) ranged from 79.5 to 86.5 dB (A), depending on the MRI sequence, with brief sound pressure peaks up to 120 dB SPL. No significant incidence of temporary threshold shift and no reduction of mean distortion product otoacoustic emission amplitude were apparent. However, a significant increase in distortion product otoacoustic emission amplitude variability after noise exposure with equal distribution of increased and decreased amplitudes was observed. This variability showed a maximum at 15 minutes after noise, as demonstrated by continuous measurements. CONCLUSIONS First, MRI noise does not impose a risk to hearing function under the measurement condition of a sound-damping head support or ear protectors. Second, a subtle effect is demonstrated by increased distortion product otoacoustic emission amplitude variability. Third, the increased otoacoustic emission amplitude variability is an audiometric parameter that is extremely sensitive to effects of acoustic stimulation, indicating more discrete changes in cochlear activity than pure-tone audiometry or otoacoustic emission amplitude reduction. A shift of the operation point (OP) of the outer hair cell (OHC) between basilar membrane and tectorial membrane is suggested as underlying cause.
Collapse
Affiliation(s)
- Wolfgang Wagner
- Department of Otorhinolaryngology, University of Tübingen, Elfriede-Aulhorn-Strasse 5, 72076 Tübingen, Germany.
| | | | | | | | | | | |
Collapse
|
26
|
Ozturan O, Erdem T, Miman MC, Kalcioglu MT, Oncel S. Effects of the electromagnetic field of mobile telephones on hearing. Acta Otolaryngol 2002; 122:289-93. [PMID: 12030576 DOI: 10.1080/000164802753648178] [Citation(s) in RCA: 60] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/16/2022]
Abstract
The widespread use of mobile telephones has given rise to concern about the potential influences of electromagnetic fields (EMFs) on human health. Anatomically, the ear is in close proximity to the mobile telephone during use. Hearing loss due to mobile telephone use has not been described in the medical literature; however, if there is a subtle cochlear involvement, it might be detected by means of changes in evoked otoacoustic emissions (OAEs). Thirty volunteers with normal hearing were exposed to mobile telephone EMFs for 10 min and evoked OAEs were measured before and after exposure. No measurable change in evoked OAEs was detected and none of the subjects reported a deterioration in hearing level. To the best of our knowledge, this is the first study on the effects of EMFs emitted by mobile telephones on hearing. It was concluded that a 10-min exposure to the EMF emitted from a mobile telephone had no effect on hearing, at least at outer ear, middle ear and cochlear levels.
Collapse
Affiliation(s)
- Orhan Ozturan
- Department of Otorhinolaryngology, School of Medicine, Inonu University, Malatya, Turkey.
| | | | | | | | | |
Collapse
|
27
|
Kossowski M, Mom T, Guitton M, Poncet JL, Bonfils P, Avan P. Fine Alterations of Distortion-product Otoacoustic Emissions after Moderate Acoustic Overexposure in Guinea Pigs: Alteraciones moderadas de los productos de distorsion de las emisiones otoacusticas después de sobrexposición acústica moderada en cobayos. Int J Audiol 2001. [DOI: 10.3109/00206090109073106] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|