1
|
Maikos JT, Chomack JM, Loan JP, Bradley KM, D'Andrea SE. Effects of Prosthetic Socket Design on Residual Femur Motion Using Dynamic Stereo X-Ray - A Preliminary Analysis. Front Bioeng Biotechnol 2021; 9:697651. [PMID: 34447740 PMCID: PMC8383143 DOI: 10.3389/fbioe.2021.697651] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2021] [Accepted: 07/21/2021] [Indexed: 11/13/2022] Open
Abstract
Individuals with transfemoral amputation experience relative motion between their residual limb and prosthetic socket, which can cause inefficient dynamic load transmission and secondary comorbidities that limit mobility. Accurately measuring the relative position and orientation of the residual limb relative to the prosthetic socket during dynamic activities can provide great insight into the complex mechanics of the socket/limb interface. Five participants with transfemoral amputation were recruited for this study. All participants had a well-fitting, ischial containment socket and were also fit with a compression/release stabilization socket. Participants underwent an 8-wk, randomized crossover trial to compare differences between socket types. Dynamic stereo x-ray was used to quantify three-dimensional residual bone kinematics relative to the prosthetic socket during treadmill walking at self-selected speed. Comfort, satisfaction, and utility were also assessed. There were no significant differences in relative femur kinematics between socket types in the three rotational degrees of freedom, as well as anterior-posterior and medial-lateral translation (p > 0.05). The ischial containment socket demonstrated significantly less proximal-distal translation (pistoning) of the femur compared to the compression/release stabilization socket during the gait cycle (p < 0.05), suggesting that the compression/release stabilization socket provided less control of the residual femur during distal translation. No significant differences in comfort and utility were found between socket types (p > 0.05). The quantitative, dynamic analytical tools used in the study were sensitive to distinguish differences in three-dimensional residual femur motion between two socket types, which can serve as a platform for future comparative effectiveness studies of socket technology.
Collapse
Affiliation(s)
- Jason T Maikos
- VISN 2 Biomechanics Research for the Advancement of Veteran Outcomes Laboratory, Veterans Affairs New York Harbor Healthcare System, New York, NY, United States
| | - John M Chomack
- VISN 2 Biomechanics Research for the Advancement of Veteran Outcomes Laboratory, Veterans Affairs New York Harbor Healthcare System, New York, NY, United States
| | | | | | - Susan E D'Andrea
- Virtual Reality and Motion Analysis Rehabilitation Laboratory, Providence VA Medical Center, Providence, RI, United States
| |
Collapse
|
2
|
Investigation of Regression Methods for Reduction of Errors Caused by Bending of FSR-Based Pressure Sensing Systems Used for Prosthetic Applications. SENSORS 2019; 19:s19245519. [PMID: 31847220 PMCID: PMC6960612 DOI: 10.3390/s19245519] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/14/2019] [Revised: 12/05/2019] [Accepted: 12/10/2019] [Indexed: 12/25/2022]
Abstract
The pressure map at the interface of a prosthetic socket and a residual limb contains information that can be used in various prosthetic applications including prosthetic control and prosthetic fitting. The interface pressure is often obtained using force sensitive resistors (FSRs). However, as reported by multiple studies, accuracies of the FSR-based pressure sensing systems decrease when sensors are bent to be positioned on a limb. This study proposes the use of regression-based methods for sensor calibration to address this problem. A sensor matrix was placed in a pressure chamber as the pressure was increased and decreased in a cyclic manner. Sensors’ responses were assessed when the matrix was placed on a flat surface or on one of five curved surfaces with various curvatures. Three regression algorithms, namely linear regression (LR), general regression neural network (GRNN), and random forest (RF), were assessed. GRNN was selected due to its performance. Various error compensation methods using GRNN were investigated and compared to improve instability of sensors’ responses. All methods showed improvements in results compared to the baseline. Developing a different model for each of the curvatures yielded the best results. This study proved the feasibility of using regression-based error compensation methods to improve the accuracy of mapping sensor readings to pressure values. This can improve the overall accuracy of FSR-based sensory systems used in prosthetic applications.
Collapse
|
3
|
Swanson E, Weathersby E, Cagle J, Sanders JE. Evaluation of Force Sensing Resistors for the Measurement of Interface Pressures in Lower Limb Prosthetics. J Biomech Eng 2019; 141:2732257. [PMID: 31017621 DOI: 10.1115/1.4043561] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2018] [Indexed: 12/14/2022]
Abstract
Understanding pressure distributions at the limb-socket interface is essential to the design and evaluation of prosthetic components for lower limb prosthesis users. Force sensing resistors (FSRs) are employed in prosthetics research to measure pressure at this interface due to their low cost, thin profile, and ease of use. While FSRs are known to be sensitive to many sources of error, few studies have systematically quantified these errors using test conditions relevant to lower limb prosthetics. The purpose of this study was to evaluate FSR accuracy for the measurement of lower limb prosthetics interface pressures. Two FSR models (Flexiforce A201 and Interlink 402) were subjected to a series of prosthetic-relevant tests. These tests included: (1) static compression, (2) cyclic compression, and (3) a combined static and cyclic compression protocol mimicking a variable activity (Walk-Sit-Stand) procedure. Flexiforce sensors outperformed Interlink sensors and were then subjected to two additional tests: (4) static curvature and (5) static shear stress. Results demonstrated that FSRs experienced significant errors all five tests. We concluded that: (1) if used carefully, FSRs can provide an estimate of prosthetic interface pressure, but these measurements should be interpreted within the expected range of possible measurement error given the setup; (2) FSRs should be calibrated in a setup that closely matches how they will be used for taking measurements; and (3) both Flexiforce and Interlink sensors can be used to estimate interface pressures, however in most cases Flexiforce sensors are likely to provide more accurate measurements.
Collapse
Affiliation(s)
- Eric Swanson
- Department of Bioengineering, University of Washington, Seattle, WA 98195
| | - Ethan Weathersby
- Department of Bioengineering, University of Washington, Seattle, WA 98195
| | - John Cagle
- Department of Bioengineering, University of Washington, Seattle, WA 98195
| | - Joan E Sanders
- Department of Bioengineering, University of Washington, Seattle, WA 98195
| |
Collapse
|
4
|
Al-Fakih E, Arifin N, Pirouzi G, Mahamd Adikan FR, Shasmin HN, Abu Osman NA. Optical fiber Bragg grating-instrumented silicone liner for interface pressure measurement within prosthetic sockets of lower-limb amputees. JOURNAL OF BIOMEDICAL OPTICS 2017; 22:1-8. [PMID: 28822140 DOI: 10.1117/1.jbo.22.8.087001] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/07/2017] [Accepted: 07/27/2017] [Indexed: 06/07/2023]
Abstract
This paper presents a fiber Bragg grating (FBG)-instrumented prosthetic silicone liner that provides cushioning for the residual limb and can successfully measure interface pressures inside prosthetic sockets of lower-limb amputees in a simple and practical means of sensing. The liner is made of two silicone layers between which 12 FBG sensors were embedded at locations of clinical interest. The sensors were then calibrated using a custom calibration platform that mimics a real-life situation. Afterward, a custom gait simulating machine was built to test the liner performance during an amputee's simulated gait. To validate the findings, the results were compared to those obtained by the commonly used F-socket mats. As the statistical findings reveal, both pressure mapping methods measured the interface pressure in a consistent way, with no significant difference (P-values ≥0.05). This pressure mapping technique in the form of a prosthetic liner will allow prosthetics professionals to quickly and accurately create an overall picture of the interface pressure distribution inside sockets in research and clinical settings, thereby improving the socket fit and amputee's satisfaction.
Collapse
Affiliation(s)
- Ebrahim Al-Fakih
- University of Malaya, Department of Biomedical Engineering, Faculty of Engineering, Kuala Lumpur, Malaysia
| | - Nooranida Arifin
- University of Malaya, Department of Biomedical Engineering, Faculty of Engineering, Kuala Lumpur, Malaysia
| | - Gholamhossein Pirouzi
- University of Malaya, Department of Biomedical Engineering, Faculty of Engineering, Kuala Lumpur, Malaysia
| | - Faisal Rafiq Mahamd Adikan
- University of Malaya, Department of Electrical Engineering, Faculty of Engineering, Kuala Lumpur, Malaysia
| | - Hanie Nadia Shasmin
- University of Malaya, Department of Biomedical Engineering, Faculty of Engineering, Kuala Lumpur, Malaysia
| | - Noor Azuan Abu Osman
- University of Malaya, Department of Biomedical Engineering, Faculty of Engineering, Kuala Lumpur, Malaysia
| |
Collapse
|
5
|
Al-Fakih EA, Abu Osman NA, Mahmad Adikan FR. Techniques for Interface Stress Measurements within Prosthetic Sockets of Transtibial Amputees: A Review of the Past 50 Years of Research. SENSORS 2016; 16:s16071119. [PMID: 27447646 PMCID: PMC4970162 DOI: 10.3390/s16071119] [Citation(s) in RCA: 52] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/18/2016] [Revised: 05/12/2016] [Accepted: 06/02/2016] [Indexed: 11/18/2022]
Abstract
The distribution of interface stresses between the residual limb and prosthetic socket of a transtibial amputee has been considered as a direct indicator of the socket quality fit and comfort. Therefore, researchers have been very interested in quantifying these interface stresses in order to evaluate the extent of any potential damage caused by the socket to the residual limb tissues. During the past 50 years a variety of measurement techniques have been employed in an effort to identify sites of excessive stresses which may lead to skin breakdown, compare stress distributions in various socket designs, and evaluate interface cushioning and suspension systems, among others. The outcomes of such measurement techniques have contributed to improving the design and fitting of transtibial sockets. This article aims to review the operating principles, advantages, and disadvantages of conventional and emerging techniques used for interface stress measurements inside transtibial sockets. It also reviews and discusses the evolution of different socket concepts and interface stress investigations conducted in the past five decades, providing valuable insights into the latest trends in socket designs and the crucial considerations for effective stress measurement tools that lead to a functional prosthetic socket.
Collapse
Affiliation(s)
- Ebrahim A Al-Fakih
- Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur 50603, Malaysia.
| | - Noor Azuan Abu Osman
- Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur 50603, Malaysia.
| | - Faisal Rafiq Mahmad Adikan
- Department of Electrical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur 50603, Malaysia.
| |
Collapse
|
6
|
Yiğiter K, Sener G, Bayar K. Comparison of the effects of patellar tendon bearing and total surface bearing sockets on prosthetic fitting and rehabilitation. Prosthet Orthot Int 2002; 26:206-12. [PMID: 12562067 DOI: 10.1080/03093640208726649] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Patellar tendon bearing (PTB) and total surface bearing (TSB) sockets have been used respectively in the prosthetic treatment of 20 trans-tibial amputees to investigate the effectiveness of both sockets on prosthetic fitting and rehabilitation. Data analysis showed that prostheses with TSB sockets were lighter than the prostheses with PTB sockets and better suspension was obtained from TSB prosthetic socket (p<0.05). It was also found that weight acceptance on the amputated side advanced to a more normal value with TSB prostheses (p<0.05). There was a statistically significant difference between the two socket types in walking and in other ambulation activities except sitting and standing up from a chair, in favour of the TSB socket (p<0.05). Consequently, due to the outcome of this study it can be said that TSB prosthetic sockets can be used effectively in the rehabilitation of trans-tibial amputees.
Collapse
Affiliation(s)
- K Yiğiter
- Department of Prosthetics and Biomechanics, School of Physical Therapy and Rehabilitation, Hacettepe University, Ankara, Turkey.
| | | | | |
Collapse
|
7
|
Polliack AA, Craig DD, Sieh RC, Landsberger S, Mcneal DR. Laboratory and clinical tests of a prototype pressure sensor for clincial assessment of prosthetic socket fit. Prosthet Orthot Int 2002; 26:23-34. [PMID: 12043923 DOI: 10.1080/03093640208726618] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Lower limb prosthetic socket fabrication is a highly refined process relying on the prosthetist's skill and experience. Despite their best efforts, patients often return with complications. Additionally, clinical application of technological advances for the quantification of biomechanical factors at the socket interface has not changed in practice. Measuring pressure levels at the stump/socket interface could provide valuable information in the process of prosthetic socket fabrication, fit and modification. This paper presents findings on the performance of a prototype capacitance pressure sensor designed for prosthetic socket use. Bench tests using compressed air were performed to measure accuracy, hysteresis and drift responses in both a flatbed chamber and a custom-modified pressure vessel. For the contoured testing, the sensors were placed on nine sites on a positive trans-tibial stump mould and enveloped with a silicone liner. Additionally, a preliminary clinical evaluation was performed with two trans-tibial amputee subjects at the nine sites during normal ambulation. Bench test results showed that the prototype capacitance sensor performed well in all categories, exhibiting a 2.42% (flatbed) and 9.96% (contoured) accuracy error, a 12.93% (flatbed) and 12.95% (contoured) hysteresis error, and a 4.40% (flatbed) and 6.20% (contoured) drift error. The clinical study showed that after three hours of continual use, no noticeable sensor drift occurred between pre and post-test calibration values. The results from this study were encouraging and the authors hope to conduct further laboratory and clinical trials to assess the influence of shear force and dynamic loading on sensor response.
Collapse
Affiliation(s)
- A A Polliack
- Rehabilitation Engineering Program, Rancho Los Amigos National Rehabilitation Center, Downey, CA, USA.
| | | | | | | | | |
Collapse
|