Mroz S, Baddour N, Dumond P, Lemaire ED. Design and prototype validation of a laterally mounted powered hip joint prothesis. J Rehabil Assist Technol Eng 2024; 11:20556683241248584. [PMID: 38694842 PMCID: PMC11062215 DOI: 10.1177/20556683241248584] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2024] [Accepted: 04/05/2024] [Indexed: 05/04/2024] Open
Abstract
Prosthetic technology has advanced with the development of powered prostheses to enhance joint function and movement in the absence of native anatomy. However, there are no powered solutions available for hip-level amputees, and most existing hip prostheses are mounted to the front of the prosthetic socket, thereby limiting range of motion. This research introduces a novel laterally mounted powered hip joint (LMPHJ) that augments user movement. The LMPHJ is mounted on the lateral side of the prosthetic socket, positioning the hip joint closer to the anatomical center of rotation while ensuring user safety and stability. The motor and electronics are located in the thigh area, maintaining a low profile while transmitting the required hip moment to the mechanical joint center of rotation. A prototype was designed and manufactured, and static testing was complete by modifying the loading conditions defined in the ISO 15032:2000 standard to failure test levels for a 100 kg person, demonstrating the joint's ability to withstand everyday loading conditions. Functional testing was conducted using a prosthesis simulator that enabled able-bodied participants to successfully walk with the powered prosthesis on level ground. This validates the mechanical design for walking and indicates the LMPHJ is ready for evaluation in the next phase with hip disarticulation amputee participants.
Collapse
Affiliation(s)
- Sarah Mroz
- Department of Mechanical Engineering, University of Ottawa, Ottawa, ON, Canada
| | - Natalie Baddour
- Department of Mechanical Engineering, University of Ottawa, Ottawa, ON, Canada
| | - Patrick Dumond
- Department of Mechanical Engineering, University of Ottawa, Ottawa, ON, Canada
| | | |
Collapse
|
2
|
Gholizadeh H, Baddour N, Botros M, Brannen K, Golshan F, Lemaire ED. Hip disarticulation and hemipelvectomy prostheses: A review of the literature. Prosthet Orthot Int 2021; 45:434-439. [PMID: 34524261 DOI: 10.1097/pxr.0000000000000029] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/19/2021] [Accepted: 07/27/2021] [Indexed: 02/03/2023]
Abstract
BACKGROUND Although the global population of people with a hip disarticulation (HD) or hemipelvectomy (HP) amputation is small, the degree of disability is high, affecting function and independence. A comprehensive literature review is needed to examine the evidence for prostheses in these amputation levels. METHOD A scoping literature review was conducted to examine related research documents from 1950 to September 2020, found using Scopus, Web of Science, PubMed, and Google Scholar databases. Studies evaluated (retrospectively or prospectively) HD or HP prostheses and were written in English. Study design and protocol, research instrument, sample size, and outcome measures were reviewed. RESULTS In the past 70 years, 53 articles that evaluated HD or HP prostheses were published. Most research was conducted in the United States (24 articles) and Japan (nine articles). In 42 articles, authors prospectively evaluated the effects of prostheses in these amputation levels. On average, prospective studies had four (SD = 5) participants. Since 1950, only five prospective studies evaluated HD or HP prostheses with 10 or more participants. Moreover, sufficient information was often unavailable for research replication. CONCLUSION More evidence is needed regarding the effects of HD or HP prosthetic components (i.e. hip, knee, ankle, socket type, and suspension system) on gait, patient satisfaction, prosthetic use, interface pressure, and energy expenditure. Articles mostly have small sample sizes that reduce confidence in the reliability of their findings and limit generalizability. Future investigations are needed with vigorous methodology and larger sample sizes to provide strong statistical conclusions.
Collapse
Affiliation(s)
- Hossein Gholizadeh
- Ottawa Hospital Research Institute, Centre for Rehabilitation Research and Development, Ottawa, Canada
| | - Natalie Baddour
- Faculty of Engineering, Department of Mechanical Engineering, University of Ottawa, Ottawa, Canada
| | - Michael Botros
- Faculty of Engineering, Department of Mechanical Engineering, University of Ottawa, Ottawa, Canada
| | - Kelly Brannen
- Faculty of Engineering, Department of Mechanical Engineering, University of Ottawa, Ottawa, Canada
| | - Farshad Golshan
- Faculty of Engineering, Department of Mechanical Engineering, University of Ottawa, Ottawa, Canada
| | - Edward D Lemaire
- Ottawa Hospital Research Institute, Centre for Rehabilitation Research and Development, Ottawa, Canada
- Faculty of Medicine, University of Ottawa, Canada
| |
Collapse
|
3
|
Schuy J, Stech N, Harris G, Beckerle P, Zahedi S, Rinderknecht S. A Prosthetic Shank With Adaptable Torsion Stiffness and Foot Alignment. Front Neurorobot 2020; 14:23. [PMID: 32457590 PMCID: PMC7225318 DOI: 10.3389/fnbot.2020.00023] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2019] [Accepted: 04/03/2020] [Indexed: 12/13/2022] Open
Abstract
Torsion adapters in lower limb prostheses aim to increase comfort, mobility and health of users by allowing rotation in the transversal plane. A preliminary study with two transtibial amputees indicated correlations between torsional stiffness and foot alignment to increase comfort and stability of the user depending on the gait situation and velocity. This paper presents the design and proof-of-concept of an active, bio-inspired prosthetic shank adapter and a novel approach to create a user-specific human-machine interaction through adapting the device's properties. To provide adequate support, load data and subjective feedback of subjects are recorded and analyzed regarding defined gait situations. The results are merged to an user individual preference-setting matrix to select optimal parameters for each gait situation and velocity. A control strategy is implemented to render the specified desired torsional stiffness and transversal foot alignment values to achieve situation-dependent adaptation based on the input of designed gait detection algorithms. The proposed parallel elastic drive train mimics the functions of bones and muscles in the human shank. It is designed to provide the desired physical human-machine interaction properties along with optimized actuator energy consumption. Following test bench verification, trials with five participants with lower limb amputation at different levels are performed for basic validation. The results suggest improved movement support in turning maneuvers. Subjective user feedback confirmed a noticeable reduction of load at the stump and improved ease of turning.
Collapse
Affiliation(s)
- Jochen Schuy
- Continental Teves AG & Co. oHG, Frankfurt am Main, Germany
| | | | - Graham Harris
- Chas a Blatchford & Sons Ltd, Basingstoke, United Kingdom
| | - Philipp Beckerle
- Institute for Mechatronic Systems, Mechanical Engineering, Technische Universität Darmstadt, Darmstadt, Germany.,Elastic Lightweight Robotics Group, Robotics Research Institute, Department of Electrical Engineering and Information Technology, Technische Universität Dortmund, Dortmund, Germany
| | - Saeed Zahedi
- Chas a Blatchford & Sons Ltd, Basingstoke, United Kingdom
| | - Stephan Rinderknecht
- Institute for Mechatronic Systems, Mechanical Engineering, Technische Universität Darmstadt, Darmstadt, Germany
| |
Collapse
|
4
|
Koehler SR, Dhaher YY, Hansen AH. Cross-validation of a portable, six-degree-of-freedom load cell for use in lower-limb prosthetics research. J Biomech 2014; 47:1542-7. [DOI: 10.1016/j.jbiomech.2014.01.048] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2013] [Revised: 01/30/2014] [Accepted: 01/31/2014] [Indexed: 11/16/2022]
|
5
|
Evaluation of Gait Performance of a Hemipelvectomy Amputation Walking with a Canadian Prosthesis. Case Rep Orthop 2014; 2014:962980. [PMID: 24822145 PMCID: PMC4009312 DOI: 10.1155/2014/962980] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2013] [Accepted: 10/31/2013] [Indexed: 11/24/2022] Open
Abstract
Background. Hemipelvectomy amputation is a surgical procedure in which lower limb and a portion of pelvic are removed. There are a few studies in the literature regarding the performance of subjects with hip disarticulation during walking. However, there is no study on gait analysis of hemipelvectomy subject. Therefore, the aim of this paper was to evaluate the gait and stability of subject with hemipelvectomy amputation. Case Description and Methods. A subject with hemipelvectomy amputation at right side was involved in this study. He used a Canadian prosthesis with single axis ankle joint, 3R21 knee joint, and 7E7 hip joint for more than 10 years. The kinetic and kinematic parameters were collected by a motion analysis system and a Kistler force platform. Findings and Outcomes. There was a significant difference between knee, hip, and ankle range of motions and their moments in the sound and prosthesis sides. In the other side, the stability of the subject in the anteroposterior direction seems to be better than that in the mediolateral direction. Conclusions. There was a significant asymmetry between the kinetic and kinematic performance of the sound and prosthesis sides, which may be due to lack of muscular power and alignment of prosthesis components.
Collapse
|
6
|
Frossard L, Gow DL, Hagberg K, Cairns N, Contoyannis B, Gray S, Brånemark R, Pearcy M. Apparatus for monitoring load bearing rehabilitation exercises of a transfemoral amputee fitted with an osseointegrated fixation: a proof-of-concept study. Gait Posture 2010; 31:223-8. [PMID: 19926285 DOI: 10.1016/j.gaitpost.2009.10.010] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/30/2009] [Revised: 10/06/2009] [Accepted: 10/20/2009] [Indexed: 02/02/2023]
Abstract
The purpose of this proof-of-concept study was to determine the relevance of direct measurements to monitor the load applied on the osseointegrated fixation of transfemoral amputees during static load bearing exercises. The objectives were (A) to introduce an apparatus using a three-dimensional load transducer, (B) to present a range of derived information relevant to clinicians, (C) to report on the outcomes of a pilot study and (D) to compare the measurements from the transducer with those from the current method using a weighing scale. One transfemoral amputee fitted with an osseointegrated implant was asked to apply 10 kg, 20 kg, 40 kg and 80 kg on the fixation, using self-monitoring with the weighing scale. The loading was directly measured with a portable kinetic system including a six-channel transducer, external interface circuitry and a laptop. As the load prescribed increased from 10 kg to 80 kg, the forces and moments applied on and around the antero-posterior axis increased by four-fold anteriorly and 14-fold medially, respectively. The forces and moments applied on and around the medio-lateral axis increased by nine-fold laterally and 16-fold from anterior to posterior, respectively. The long axis of the fixation was overloaded and underloaded in 17% and 83% of the trials, respectively, by up to + or - 10%. This proof-of-concept study presents an apparatus that can be used by clinicians facing the challenge of improving basic knowledge on osseointegration, for the design of equipment for load bearing exercises and for rehabilitation programs.
Collapse
Affiliation(s)
- Laurent Frossard
- School of Engineering Systems, Queensland University of Technology, Brisbane, Australia.
| | | | | | | | | | | | | | | |
Collapse
|
7
|
Frossard L, Hagberg K, Haggstrom E, Branemark R. Load-relief of walking AIDS on osseointegrated fixation: instrument for evidence-based practice. IEEE Trans Neural Syst Rehabil Eng 2009; 17:9-14. [PMID: 19211318 DOI: 10.1109/tnsre.2008.2010478] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Clinicians are currently in demand of tools enabling individual assessment during their daily practice of load-relief of walking aids. The first aim of this article is to describe a portable kinetic system that could be used to measure directly the true load applied on the residuum during assisted walking. The second aim is to present the information that can be derived from the raw loading data. The third aim is to provide an example for a participant. One active transfemoral amputee fitted with an osseointegrated fixation was asked to walk in straight level line with no aid, one stick, one and two elbow crutches on a 20 m walkway. The load-relief was measured using a six-channel transducer and recorded using a data logger. The overall loading was decreased by 2% using one stick, 5% using one crutch and by 10% using two crutches. This study presents a method that can be used by clinicians facing the challenge of prescribing and assessing walking aids to restore the locomotion of lower limb amputees in the framework of an evidence-based practice.
Collapse
Affiliation(s)
- Laurent Frossard
- School of Engineering Systems and Institute of Health and Biomedical Innovation, Queensland University of Technology, Brisbane, Australia
| | | | | | | |
Collapse
|
8
|
Frossard L, Stevenson N, Smeathers J, Häggström E, Hagberg K, Sullivan J, Ewins D, Gow DL, Gray S, Brånemark R. Monitoring of the load regime applied on the osseointegrated fixation of a trans-femoral amputee: a tool for evidence-based practice. Prosthet Orthot Int 2008; 32:68-78. [PMID: 18330805 DOI: 10.1080/03093640701676319] [Citation(s) in RCA: 49] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
This study aimed to provide a description of the continuous recording of the true load regime experienced during daily living by the abutment of a trans-femoral amputee fitted with an osseointegrated fixation. The specific objectives: (i) To present an apparatus and a procedure allowing recording of the load regime, and (ii) an example of the raw data and six performance indicators of the usage of the prosthesis obtained with this method. A subject was monitored for a period of 5 hours as he went about his daily activities. The load regime was directly measured and recorded using a commercial transducer and data logger. The overall load profile presented alternative periods of variable length of inactivity (64%) and activity (36%), respectively. The maximum load applied on the mediolateral, anteroposterior and the long axes represented 21%, 21% and 120% of the body weight, respectively. The anteroposterior, mediolateral and long components of the impulse were 395 kN.s, 359 kN.s and 2,323 kN.s, respectively. The amputee generated a total of 2312 gait cycles of the prosthetic leg, giving an approximate overall cadence of 8 stride/min. Preliminary outcomes indicated that the proposed method was an improvement on the current techniques as it provided the true loading and actual usage of the prosthesis during daily living. This study is a stepping stone in the development of future affordable, on-board and user-friendly load recording systems that can be used in evidence-based practice.
Collapse
Affiliation(s)
- Laurent Frossard
- School of Engineering Systems, Queensland University of Technology, Brisbane, Australia.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
9
|
Let Them Walk! Current Prosthesis Options for Leg and Foot Amputees. J Am Coll Surg 2008; 206:548-60. [DOI: 10.1016/j.jamcollsurg.2007.10.007] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2007] [Revised: 10/02/2007] [Accepted: 10/15/2007] [Indexed: 12/12/2022]
|
10
|
Lee WCC, Frossard LA, Hagberg K, Haggstrom E, Gow DL, Gray S, Brånemark R. Magnitude and variability of loading on the osseointegrated implant of transfemoral amputees during walking. Med Eng Phys 2007; 30:825-33. [PMID: 17977050 DOI: 10.1016/j.medengphy.2007.09.003] [Citation(s) in RCA: 50] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2007] [Revised: 09/24/2007] [Accepted: 09/24/2007] [Indexed: 10/22/2022]
Abstract
This study directly measured the load acting on the abutment of the osseointegrated implant system of transfemoral amputees during level walking, and studied the variability of the load within and among amputees. Twelve active transfemoral amputees (age: 54 +/- 12 years, mass: 84.3 +/- 16.3 kg, height: 17.8 +/- 0.10 m) fitted with an osseointegrated implant for over 1 year participated in the study. The load applied on the abutment was measured during unimpeded, level walking in a straight line using a commercial six-channel transducer mounted between the abutment and the prosthetic knee. The pattern and the magnitude of the three-dimensional forces and moments were revealed. Results showed a low step-to-step variability of each subject, but a high subject-to-subject variability in local extrema of body-weight normalized forces and moments and impulse data. The high subject-to-subject variability suggests that the mechanical design of the implant system should be customized for each individual, or that a fit-all design should take into consideration the highest values of load within a broad range of amputees. It also suggests specific loading regime in rehabilitation training are necessary for a given subject. Thus the loading magnitude and variability demonstrated should be useful in designing an osseointegrated implant system better able to resist mechanical failure and in refining the rehabilitation protocol.
Collapse
Affiliation(s)
- Winson C C Lee
- School of Engineering Systems, Queensland University of Technology, Brisbane, Australia.
| | | | | | | | | | | | | |
Collapse
|
11
|
Kinetics of transfemoral amputees with osseointegrated fixation performing common activities of daily living. Clin Biomech (Bristol, Avon) 2007; 22:665-73. [PMID: 17400346 DOI: 10.1016/j.clinbiomech.2007.02.005] [Citation(s) in RCA: 79] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/12/2006] [Revised: 02/09/2007] [Accepted: 02/12/2007] [Indexed: 02/07/2023]
Abstract
BACKGROUND Direct anchorage of a lower-limb prosthesis to the bone through an implanted fixation (osseointegration) has been suggested as an excellent alternative for amputees experiencing complications from use of a conventional socket-type prosthesis. However, an attempt needs to be made to optimize the mechanical design of the fixation and refine the rehabilitation program. Understanding the load applied on the fixation is a crucial step towards this goal. METHODS The load applied on the osseointegrated fixation of nine transfemoral amputees was measured using a load transducer, when the amputees performed activities which included straight-line level walking, ascending and descending stairs and a ramp as well as walking around a circle. Force and moment patterns along each gait cycle, magnitudes and time of occurrence of the local extrema of the load, as well as impulses were analysed. FINDINGS Managing a ramp and stairs, and walking around a circle did not produce a significant increase (P>0.05) in load compared to straight-line level walking. The patterns of the moment about the medio-lateral axis were different among the six activities which may reflect the different strategies used in controlling the prosthetic knee joint. INTERPRETATIONS This study increases the understanding of biomechanics of bone-anchored osseointegrated prostheses. The loading data provided will be useful in designing the osseointegrated fixation to increase the fatigue life and to refine the rehabilitation protocol.
Collapse
|
12
|
Frossard L, Stevenson N, Smeathers J, Lee Gow D, Gray S, Sullivan J, Daniel C, Haggstrom E, Hagberg K, Brånemark R. Activités quotidiennes d’un amputé transfémoral équipé d’une fixation ostéo-intégrée : enregistrement continu des efforts pour une pratique fondée sur des preuves. ACTA ACUST UNITED AC 2006. [DOI: 10.1016/s1779-0123(06)70226-1] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
13
|
Development and Preliminary Testing of a Device for the Direct Measurement of Forces and Moments in the Prosthetic Limb of Transfemoral Amputees during Activities of Daily Living. ACTA ACUST UNITED AC 2003. [DOI: 10.1097/00008526-200310000-00005] [Citation(s) in RCA: 53] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|