1
|
Farkas Á. Simulation of the effect of mucociliary clearance on the bronchial distribution of inhaled radon progenies and related cellular damage using a new deposition and clearance model for the lung. RADIATION AND ENVIRONMENTAL BIOPHYSICS 2020; 59:651-661. [PMID: 32865689 PMCID: PMC7544752 DOI: 10.1007/s00411-020-00868-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/20/2020] [Accepted: 08/17/2020] [Indexed: 05/27/2023]
Abstract
Most of the current dosimetry models of inhaled short-lived radon decay products assume uniform activity distributions along the bronchial airways. In reality, however, both deposition and clearance patterns of inhaled radon progenies are highly inhomogeneous. Consequently, a new deposition-clearance model has been developed that accounts for such inhomogeneities and applied together with biophysical models of cell death and cell transformation. The scope of this study was to apply this model which is based on computational fluid and particle dynamics methods, in an effort to reveal the effect of mucociliary clearance on the bronchial distribution of deposited radon progenies. Furthermore, the influence of mucociliary clearance on the spatial distribution of biological damage due to alpha-decay of the deposited radon progenies was also studied. The results obtained demonstrate that both deposition and clearance of inhaled radon progenies are highly non-uniform within a human airway bifurcation unit. Due to the topology of the carinal ridge, a slow clearance zone emerged in this region, which is the location where most of the radio-aerosols deposit. In spite of the slow mucus movement in this zone, the initial degree of inhomogeneity of the activity due to the nonuniform deposition decreased by a factor of about 3 by considering the effect of mucociliary clearance. In the peak of the airway bifurcation, the computed cell death and cell transformation probabilities were lower when considering deposition and clearance simultaneously, compared to the case when only deposition was considered. However, cellular damage remained clustered.
Collapse
Affiliation(s)
- Árpád Farkas
- Environmental Physics Department, Centre for Energy Research, Konkoly-Thege M. út 29-33, 1121, Budapest, Hungary.
| |
Collapse
|
2
|
Inhaled nanoparticles-An updated review. Int J Pharm 2020; 587:119671. [PMID: 32702456 DOI: 10.1016/j.ijpharm.2020.119671] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2020] [Revised: 07/14/2020] [Accepted: 07/15/2020] [Indexed: 11/21/2022]
Abstract
We are providing an update to our previously published review paper on inhaled nanoparticles, thus updating with the most recent reports in the literature. The field of nanotechnology may hold the promise of significant improvements in the health and well-being of patients, as well as in manufacturing technologies. The knowledge of the impact of nanomaterials on public health is limited so far. This paper reviews the unique size-controlled properties of nanomaterials, their disposition in the body after inhalation, and the factors influencing the fate of inhaled nanomaterials. The physiology of the lungs makes it an ideal target organ for non-invasive local and systemic drug delivery, especially for protein and poorly water-soluble drugs that have low oral bioavailability via oral administration. More recently, inhaled nanoparticles have been reported to improve therapeutic efficacies and decrease undesirable side effects via pulmonary delivery. The potential application of pulmonary drug delivery of nanoparticles to the lungs, specifically in context of published results reported on nanomaterials in environmental epidemiology and toxicology is reviewed in this paper. This article presents updated delivery systems, process technologies, and potential of inhaled nanoparticles for local and systemic therapies administered to the lungs. The authors acknowledge the contributions of Wei Yang in our 2008 paper published in this journal.
Collapse
|
3
|
Madas BG, Drozsdik EJ. Effects of mucus thickness and goblet cell hyperplasia on microdosimetric quantities characterizing the bronchial epithelium upon radon exposure. Int J Radiat Biol 2018; 94:967-974. [PMID: 30265181 DOI: 10.1080/09553002.2018.1511931] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
Abstract
PURPOSE The most exposed tissue upon radon exposure is the bronchial epithelium where goblet cells serve as responsive and adaptable front-line defenders. They can rapidly produce a vast amount of mucus, and can change in number, in response to airway insults. The objective of the present study is to quantify the effects of mucus discharge and goblet cell hyperplasia on the microscopic dose consequences of macroscopic radon exposures. METHODS For this purpose, computational models of the bronchial epithelium and alpha-particle transport have been prepared and applied to quantify the hits received and doses absorbed by cell nuclei in case of different mucus thicknesses and goblet cell number. RESULTS AND CONCLUSIONS Both mucus discharge and induction of goblet cell hyperplasia reduce radiation burden at the cellular level, and as such they both can be considered as radioadaptive responses to radon exposure. As compared to basal cell hyperplasia, goblet cell hyperplasia is more effective in reducing the microscopic dose consequences of a given macroscopic exposure. Such changes in exposure geometry highlight the need for improvements in the application of biokinetic and dosimetry models for incorporated radionuclides as well as the dose and dose rate effectiveness factor.
Collapse
Affiliation(s)
| | - Emese J Drozsdik
- a MTA Centre for Energy Research , Budapest , Hungary.,b Doctoral School of Physics , ELTE Eötvös Loránd University , Budapest , Hungary
| |
Collapse
|
4
|
Manolidis M, Isabey D, Louis B, Grotberg JB, Filoche M. A Macroscopic Model for Simulating the Mucociliary Clearance in a Bronchial Bifurcation: The Role of Surface Tension. J Biomech Eng 2016; 138:2546609. [DOI: 10.1115/1.4034507] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2015] [Indexed: 11/08/2022]
Abstract
The mucociliary clearance in the bronchial tree is the main mechanism by which the lungs clear themselves of deposited particulate matter. In this work, a macroscopic model of the clearance mechanism is proposed. Lubrication theory is applied for thin films with both surface tension effects and a moving wall boundary. The flow field is computed by the use of a finite-volume scheme on an unstructured grid that replicates a bronchial bifurcation. The carina in bronchial bifurcations is of special interest because it is a location of increased deposition of inhaled particles. In this study, the mucus flow is computed for different values of the surface tension. It is found that a minimal surface tension is necessary for efficiently removing the mucus while maintaining the mucus film thickness at physiological levels.
Collapse
Affiliation(s)
- Michail Manolidis
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI 48109
- Laboratoire de Physique de la Matière Condensée, Ecole Polytechnique, CNRS, Université Paris-Saclay, Palaiseau Cedex 91128, France e-mail:
| | - Daniel Isabey
- Professor Inserm, U955 (Equipe13) and CNRS ERL 7240, Cell and Respiratory Biomechanics, Université Paris Est, Créteil 94010, France e-mail:
| | - Bruno Louis
- Inserm, U955 (Equipe13) and CNRS ERL 7240, Cell and Respiratory Biomechanics, Université Paris Est, Créteil 94010, France e-mail:
| | - James B. Grotberg
- Professor Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI 48109 e-mail:
| | - Marcel Filoche
- Professor Laboratoire de Physique de la Matière Condensée, Ecole Polytechnique, CNRS, Université Paris-Saclay, Palaiseau Cedex 91128, France; Inserm, U955 (Equipe13) and CNRS ERL 7240, Cell and Respiratory Biomechanics, Université Paris Est, Créteil 94010, France e-ail:
| |
Collapse
|
5
|
Madas BG. Radon induced hyperplasia: effective adaptation reducing the local doses in the bronchial epithelium. JOURNAL OF RADIOLOGICAL PROTECTION : OFFICIAL JOURNAL OF THE SOCIETY FOR RADIOLOGICAL PROTECTION 2016; 36:653-666. [PMID: 27517484 DOI: 10.1088/0952-4746/36/3/653] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
There is experimental and histological evidence that chronic irritation and cell death may cause hyperplasia in the exposed tissue. As the heterogeneous deposition of inhaled radon progeny results in high local doses at the peak of the bronchial bifurcations, it was proposed earlier that hyperplasia occurs in these deposition hot spots upon chronic radon exposure. The objective of the present study is to quantify how the induction of basal cell hyperplasia modulates the microdosimetric consequences of a given radon exposure. For this purpose, computational epithelium models were constructed with spherical cell nuclei of six different cell types based on histological data. Basal cell hyperplasia was modelled by epithelium models with additional basal cells and increased epithelium thickness. Microdosimetry for alpha-particles was performed by an own-developed Monte-Carlo code. Results show that the average tissue dose, and the average hit number and dose of basal cells decrease by the increase of the measure of hyperplasia. Hit and dose distribution reveal that the induction of hyperplasia may result in a basal cell pool which is shielded from alpha-radiation. It highlights that the exposure history affects the microdosimetric consequences of a present exposure, while the biological and health effects may also depend on previous exposures. The induction of hyperplasia can be considered as a radioadaptive response at the tissue level. Such an adaptation of the tissue challenges the validity of the application of the dose and dose rate effectiveness factor from a mechanistic point of view. As the location of radiosensitive target cells may change due to previous exposures, dosimetry models considering the tissue geometry characteristic of normal conditions may be inappropriate for dose estimation in case of protracted exposures. As internal exposures are frequently chronic, such changes in tissue geometry may be highly relevant for other incorporated radionuclides.
Collapse
Affiliation(s)
- Balázs G Madas
- Radiation Biophysics Group, Environmental Physics Department, Centre for Energy Research, Hungarian Academy of Sciences, 1121 Budapest, Konkoly-Thege Miklós út 29-33., Hungary
| |
Collapse
|
6
|
Madas BG. Radon Exposure and the Definition of Low Doses-The Problem of Spatial Dose Distribution. HEALTH PHYSICS 2016; 111:47-51. [PMID: 27218294 DOI: 10.1097/hp.0000000000000516] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
Investigating the health effects of low doses of ionizing radiation is considered to be one of the most important fields in radiological protection research. Although the definition of low dose given by a dose range seems to be clear, it leaves some open questions. For example, the time frame and the target volume in which absorbed dose is measured have to be defined. While dose rate is considered in the current system of radiological protection, the same cancer risk is associated with all exposures, resulting in a given amount of energy absorbed by a single target cell or distributed among all the target cells of a given organ. However, the biological effects and so the health consequences of these extreme exposure scenarios are unlikely to be the same. Due to the heterogeneous deposition of radon progeny within the lungs, heterogeneous radiation exposure becomes a practical issue in radiological protection. While the macroscopic dose is still within the low dose range, local tissue doses on the order of Grays can be reached in the most exposed parts of the bronchial airways. It can be concluded that progress in low dose research needs not only low dose but also high dose experiments where small parts of a biological sample receive doses on the order of Grays, while the average dose over the whole sample remains low. A narrow interpretation of low dose research might exclude investigations with high relevance to radiological protection. Therefore, studies important to radiological protection should be performed in the frame of low dose research even if the applied doses do not fit in the dose range used for the definition of low doses.
Collapse
Affiliation(s)
- Balázs G Madas
- *Environmental Physics Department, Centre for Energy Research, Hungarian Academy of Sciences
| |
Collapse
|
7
|
Farkas Á, Balásházy I. Development and application of a complex numerical model and software for the computation of dose conversion factors for radon progenies. RADIATION PROTECTION DOSIMETRY 2015; 164:278-290. [PMID: 25236336 DOI: 10.1093/rpd/ncu269] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/30/2014] [Accepted: 07/30/2014] [Indexed: 06/03/2023]
Abstract
A more exact determination of dose conversion factors associated with radon progeny inhalation was possible due to the advancements in epidemiological health risk estimates in the last years. The enhancement of computational power and the development of numerical techniques allow computing dose conversion factors with increasing reliability. The objective of this study was to develop an integrated model and software based on a self-developed airway deposition code, an own bronchial dosimetry model and the computational methods accepted by International Commission on Radiological Protection (ICRP) to calculate dose conversion coefficients for different exposure conditions. The model was tested by its application for exposure and breathing conditions characteristic of mines and homes. The dose conversion factors were 8 and 16 mSv WLM(-1) for homes and mines when applying a stochastic deposition model combined with the ICRP dosimetry model (named PM-A model), and 9 and 17 mSv WLM(-1) when applying the same deposition model combined with authors' bronchial dosimetry model and the ICRP bronchiolar and alveolar-interstitial dosimetry model (called PM-B model). User friendly software for the computation of dose conversion factors has also been developed. The software allows one to compute conversion factors for a large range of exposure and breathing parameters and to perform sensitivity analyses.
Collapse
Affiliation(s)
- Árpád Farkas
- Centre for Energy Research, Hungarian Academy of Sciences, H-1525, Budapest, PO Box 49, Konkoly-Thege Miklós út 29-33, Budapest 1121, Hungary
| | - Imre Balásházy
- Centre for Energy Research, Hungarian Academy of Sciences, H-1525, Budapest, PO Box 49, Konkoly-Thege Miklós út 29-33, Budapest 1121, Hungary
| |
Collapse
|
8
|
Aerts AM, Impens NREN, Baatout S, Benotmane MA, Camps J, Dabin JM, Derradji H, Grosche B, Horemans N, Jourdain JR, Moreels M, Perko T, Quintens R, Repussard J, Rühm W, Schneider T, Struelens L, Hardeman F. Joint research towards a better radiation protection-highlights of the Fifth MELODI Workshop. JOURNAL OF RADIOLOGICAL PROTECTION : OFFICIAL JOURNAL OF THE SOCIETY FOR RADIOLOGICAL PROTECTION 2014; 34:931-56. [PMID: 25431966 DOI: 10.1088/0952-4746/34/4/931] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
MELODI is the European platform dedicated to low-dose radiation risk research. From 7 October through 10 October 2013 the Fifth MELODI Workshop took place in Brussels, Belgium. The workshop offered the opportunity to 221 unique participants originating from 22 countries worldwide to update their knowledge and discuss radiation research issues through 118 oral and 44 poster presentations. In addition, the MELODI 2013 workshop was reaching out to the broader radiation protection community, rather than only the low-dose community, with contributions from the fields of radioecology, emergency and recovery preparedness, and dosimetry. In this review, we summarise the major scientific conclusions of the workshop, which are important to keep the MELODI strategic research agenda up-to-date and which will serve to establish a joint radiation protection research roadmap for the future.
Collapse
Affiliation(s)
- A M Aerts
- Institute for Environment, Health and Safety, Belgian Nuclear Research Centre (SCK•CEN), Mol, Belgium
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|