1
|
Wang R, Xu K, Luo J, Chao X, Hu F, Zhang D, Chen Y, Li Y, Fan Z, Wang H, Xu L. Vestibular function and hearing preservation in children following a minimally invasive cochlear implantation. Eur Arch Otorhinolaryngol 2024; 281:4029-4038. [PMID: 38341823 PMCID: PMC11266237 DOI: 10.1007/s00405-024-08504-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2023] [Accepted: 01/24/2024] [Indexed: 02/13/2024]
Abstract
PURPOSE This retrospective cohort study aimed to investigate the effect of minimally invasive cochlear implantation (CI) on the vestibular function (VF) and residual hearing (RH) as well as their relationship in pediatric recipients before and after surgery. METHODS Twenty-four pediatric patients with preoperative low frequency residual hearing (LFRH) (250 or 500 Hz ≤ 80 dB HL) who underwent minimally invasive CI were enrolled. Pure-tone thresholds, the cervical/ocular vestibular-evoked myogenic potential (cVEMP/oVEMP), and video head impulse test (vHIT) were all evaluated in the 24 pediatric patients with preoperative normal VF before and at 1 and 12 months after surgery. The relationship between changes in hearing and VF was analyzed preoperatively and at 1 and 12 months postoperatively. RESULTS There were no significant differences on VF preservation and hearing preservation (HP) at both 1 and 12 months post-CI (p > 0.05). At 1 month post-CI, the correlations of the variations in vestibulo-ocular reflex (VOR) gains of horizontal semicircular canal (HSC) and posterior semicircular canal (PSC) and the shift in 250 Hz threshold were negatively correlated (r = - 0.41, p = 0.04 and r = - 0.43, p = 0.04, respectively). At 12 months post-CI, the shift in 250 Hz threshold negatively correlated to the variations in VOR gain of superior semicircular canal (SSC) (r = - 0.43, p = 0.04); the HP positively correlated to the variation in oVEMP-amplitude ratio (AR) (r = 0.41, p = 0.04). CONCLUSION Our study confirmed that there were partial correlations between VF preservation and HP both in the short- and long-terms after atraumatic CI surgery, especially with the 250 Hz threshold. Regarding the variation of PSC function, the correlation with hearing status was variable with time after atraumatic CI surgery. Minimally invasive techniques for HP are successful and effective for the preservation of VF in pediatric patients both in the short- and long-terms.
Collapse
Affiliation(s)
- Ruijie Wang
- Department of Otolaryngology-Head and Neck Surgery, Shandong Provincial ENT Hospital, Shandong University, Jinan, 250022, People's Republic of China
- Department of Auditory Implantation, Shandong Provincial ENT Hospital, Jinan, China
| | - Kaifan Xu
- Department of Otolaryngology-Head and Neck Surgery, Shandong Provincial ENT Hospital, Shandong University, Jinan, 250022, People's Republic of China
- Department of Auditory Implantation, Shandong Provincial ENT Hospital, Jinan, China
| | - Jianfen Luo
- Department of Otolaryngology-Head and Neck Surgery, Shandong Provincial ENT Hospital, Shandong University, Jinan, 250022, People's Republic of China
- Department of Auditory Implantation, Shandong Provincial ENT Hospital, Jinan, China
| | - Xiuhua Chao
- Department of Otolaryngology-Head and Neck Surgery, Shandong Provincial ENT Hospital, Shandong University, Jinan, 250022, People's Republic of China
- Department of Auditory Implantation, Shandong Provincial ENT Hospital, Jinan, China
| | - Fangxia Hu
- Department of Otolaryngology-Head and Neck Surgery, Shandong Provincial ENT Hospital, Shandong University, Jinan, 250022, People's Republic of China
- Department of Auditory Implantation, Shandong Provincial ENT Hospital, Jinan, China
| | - Daogong Zhang
- Department of Otolaryngology-Head and Neck Surgery, Shandong Provincial ENT Hospital, Shandong University, Jinan, 250022, People's Republic of China
| | - Yueling Chen
- Department of Otolaryngology-Head and Neck Surgery, Shandong Provincial ENT Hospital, Shandong University, Jinan, 250022, People's Republic of China
| | - Yuanling Li
- Department of Otolaryngology-Head and Neck Surgery, Shandong Provincial ENT Hospital, Shandong University, Jinan, 250022, People's Republic of China
| | - Zhaomin Fan
- Department of Otolaryngology-Head and Neck Surgery, Shandong Provincial ENT Hospital, Shandong University, Jinan, 250022, People's Republic of China
| | - Haibo Wang
- Department of Otolaryngology-Head and Neck Surgery, Shandong Provincial ENT Hospital, Shandong University, Jinan, 250022, People's Republic of China
| | - Lei Xu
- Department of Otolaryngology-Head and Neck Surgery, Shandong Provincial ENT Hospital, Shandong University, Jinan, 250022, People's Republic of China.
- Department of Auditory Implantation, Shandong Provincial ENT Hospital, Jinan, China.
| |
Collapse
|
2
|
Licameli GR, Wang A, Zhou G, Faller D, Kenna M, Poe D, Shearer E, Oster L, Brodsky JR. Vestibular Preservation in Pediatric Cochlear Implantation. Laryngoscope 2024; 134:1913-1918. [PMID: 37584403 DOI: 10.1002/lary.30978] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2023] [Revised: 07/20/2023] [Accepted: 08/03/2023] [Indexed: 08/17/2023]
Abstract
OBJECTIVES Evaluate the rate of preserved vestibular function in pediatric cochlear implant surgery. STUDY DESIGN Retrospective case review. METHODS Pre- and post-operative vestibular tests were compared in children who underwent cochlear implantation at a tertiary level pediatric hospital over a 4-year period. RESULTS Data from 59 implanted ears in 44 children was included. Median age was 2.8 years at initial testing (range 7 months - 21 years) with 1:1 male/female ratio. Implant surgeries were 26 unilateral, 13 bilateral simultaneous, and 5 bilateral sequential. The majority were implanted with slim, non-styletted electrodes (86.4%) via a round window approach (91.5%). Normal pre-operative results were preserved post-operatively on rotary chair testing in 75% (21/28) of patients, cervical vestibular evoked myogenic potential testing in (75%) 30/40 of ears tested, ocular vestibular evoked myogenic potential testing in 85.7% (6/7) of ears tested, video head impulse testing in 100% (9/9) of ears tested, and computerized dynamic posturography in 100% (5/5) of patients tested. Overall, 62.5% of patients had no new deficits on any vestibular test performed post-operatively. CONCLUSIONS Preservation rates of vestibular function following cochlear implant surgery were higher in this cohort than what has been reported in many earlier studies. Contemporary, less traumatic electrodes and insertion techniques may be a significant factor. The risk of causing a new, severe bilateral vestibular loss with long-term functional impacts appears to be low. Further study is warranted on the impacts of different cochlear implant electrode designs and insertion approaches on post-operative vestibular preservation. LEVEL OF EVIDENCE 4, Case Series Laryngoscope, 134:1913-1918, 2024.
Collapse
Affiliation(s)
- Greg R Licameli
- Department of Otolaryngology and Communication Enhancement, Boston Children's Hospital, Boston, Massachusetts, U.S.A
- Department of Otolaryngology, Harvard Medical School, Boston, Massachusetts, U.S.A
| | - Alicia Wang
- Department of Otolaryngology and Communication Enhancement, Boston Children's Hospital, Boston, Massachusetts, U.S.A
| | - Guangwei Zhou
- Department of Otolaryngology and Communication Enhancement, Boston Children's Hospital, Boston, Massachusetts, U.S.A
- Department of Otolaryngology, Harvard Medical School, Boston, Massachusetts, U.S.A
| | - David Faller
- Department of Otolaryngology and Communication Enhancement, Boston Children's Hospital, Boston, Massachusetts, U.S.A
| | - Margaret Kenna
- Department of Otolaryngology and Communication Enhancement, Boston Children's Hospital, Boston, Massachusetts, U.S.A
- Department of Otolaryngology, Harvard Medical School, Boston, Massachusetts, U.S.A
| | - Dennis Poe
- Department of Otolaryngology and Communication Enhancement, Boston Children's Hospital, Boston, Massachusetts, U.S.A
- Department of Otolaryngology, Harvard Medical School, Boston, Massachusetts, U.S.A
| | - Eliot Shearer
- Department of Otolaryngology and Communication Enhancement, Boston Children's Hospital, Boston, Massachusetts, U.S.A
- Department of Otolaryngology, Harvard Medical School, Boston, Massachusetts, U.S.A
| | - Linda Oster
- Department of Otolaryngology and Communication Enhancement, Boston Children's Hospital, Boston, Massachusetts, U.S.A
| | - Jacob R Brodsky
- Department of Otolaryngology and Communication Enhancement, Boston Children's Hospital, Boston, Massachusetts, U.S.A
- Department of Otolaryngology, Harvard Medical School, Boston, Massachusetts, U.S.A
| |
Collapse
|
3
|
Hrncirik F, Roberts I, Sevgili I, Swords C, Bance M. Models of Cochlea Used in Cochlear Implant Research: A Review. Ann Biomed Eng 2023; 51:1390-1407. [PMID: 37087541 PMCID: PMC10264527 DOI: 10.1007/s10439-023-03192-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2023] [Accepted: 03/20/2023] [Indexed: 04/24/2023]
Abstract
As the first clinically translated machine-neural interface, cochlear implants (CI) have demonstrated much success in providing hearing to those with severe to profound hearing loss. Despite their clinical effectiveness, key drawbacks such as hearing damage, partly from insertion forces that arise during implantation, and current spread, which limits focussing ability, prevent wider CI eligibility. In this review, we provide an overview of the anatomical and physical properties of the cochlea as a resource to aid the development of accurate models to improve future CI treatments. We highlight the advancements in the development of various physical, animal, tissue engineering, and computational models of the cochlea and the need for such models, challenges in their use, and a perspective on their future directions.
Collapse
Affiliation(s)
- Filip Hrncirik
- Cambridge Hearing Group, Cambridge, UK.
- Department of Clinical Neurosciences, University of Cambridge, Cambridge, CB2 0QQ, UK.
| | - Iwan Roberts
- Cambridge Hearing Group, Cambridge, UK
- Department of Clinical Neurosciences, University of Cambridge, Cambridge, CB2 0QQ, UK
| | - Ilkem Sevgili
- Cambridge Hearing Group, Cambridge, UK
- Department of Clinical Neurosciences, University of Cambridge, Cambridge, CB2 0QQ, UK
| | - Chloe Swords
- Cambridge Hearing Group, Cambridge, UK
- Department of Physiology, Development and Neurosciences, University of Cambridge, Cambridge, CB2 3DY, UK
| | - Manohar Bance
- Cambridge Hearing Group, Cambridge, UK
- Department of Clinical Neurosciences, University of Cambridge, Cambridge, CB2 0QQ, UK
| |
Collapse
|
4
|
Vaz FDC, Petrus L, Martins WR, Silva IMDC, Lima JAO, Santos NMDS, Turri-Silva N, Bahmad F. The effect of cochlear implant surgery on vestibular function in adults: A meta-analysis study. Front Neurol 2022; 13:947589. [PMID: 36034277 PMCID: PMC9402268 DOI: 10.3389/fneur.2022.947589] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2022] [Accepted: 07/11/2022] [Indexed: 11/19/2022] Open
Abstract
Issue The findings in literature indicate inconsistency in the complications caused by the implant of electrodes in the cochlea; vestibular alterations and balance disorders are mentioned as the most likely. Purpose To evaluate, in literature, through the results of multiple vestibular function tests, the effects of cochlear implant surgery on postural stability in adult patients and to analyze. Hypothesis From the PICO strategy, where the Population focuses on adults, Intervention is cochlear implant surgery, Comparisons are between implanted patients, and Outcomes are the results of the assessment of cochlear function, the research question was formulated: Are there deficits in vestibular function in adults undergoing cochlear implant placement? Method Systematic review based on cohort, case–control, and cross-sectional observational studies. Information sources: Databases between 1980 and 2021, namely, PubMed, Cinahl, Web Of Science, Cochrane, and Scopus. Search strategy using Mesh terms: “Adult,” “Cochlear Implant,” “Postural Balance,” “Posturography,” “Cochlear Implant,” “Dizziness,” “Vertigo,” “Vestibular Functional Tests,”and “Caloric Tests.” Populational inclusion criteria: studies with adult patients; intervention: cochlear implant placement surgery; comparison: analysis of a vestibular function with vestibular test results and pre- and postoperative symptoms; outcome: studies with at least one of the vestibular function tests, such as computerized vectoelectronystagmography (VENG), vestibular-evoked myogenic potentials (VEMPs), caloric test, video head impulse test (VHIT), head impulse test (HIT), videonystagmography, (VNG) and static and dynamic posturography. Exclusion criteria: studies without records of pre- and postoperative data collection and studies with populations under 18 years of age. Screening based on the reading of abstracts and titles was performed independently by two reviewers. In the end, with the intermediation of a third reviewer, manuscripts were included. Risk of bias analysis, performed by two other authors, occurred using the JBI “Critical Appraisal Checklist.” Results Of the 757 studies, 38 articles met the inclusion criteria. VEMP was the most commonly used test by the studies (44.7%), followed by the caloric test (36.8%) and vHIT (23.6%). Most studies performed more than one test to assess vestibular function. Conclusion Among all vestibular tests investigated, the deleterious effects on vestibular function after cochlear implant surgery were detected with statistical significance (P < 0.05) using VEMP and caloric test. Comparing abnormal and normal results after implant surgery, the vestibular apparatus was evaluated as having abnormal results after cochlear implant surgery only in the VEMP test. The other tests analyzed maintained a percentage mostly considered normal results. Systematic review registration identifier: CRD42020198872.
Collapse
Affiliation(s)
- Fabiane de Castro Vaz
- Postgraduate Program in Health Sciences at the Faculty of Health Sciences, University of Brasília, Brasília, DF, Brazil
- 3ID Ensino, 3 ID Prevenção e Reabilitação Geriátrica, Brasília, DF, Brazil
| | - Leonardo Petrus
- Health and Technologies in Health Sciences Program, University of Brasília, Brasília, DF, Brazil
| | - Wagner Rodrigues Martins
- College of Physical Therapy, University of Brasília, Brasília, DF, Brazil
- College of Physical Education, University of Brasília, Brasília, DF, Brazil
| | | | - Jade Arielly Oliveira Lima
- College of Physical Therapy, University of Brasília, Brasília, DF, Brazil
- College of Physical Education, University of Brasília, Brasília, DF, Brazil
| | | | | | - Fayez Bahmad
- Postgraduate Program in Health Sciences at the Faculty of Health Sciences, University of Brasília, Brasília, DF, Brazil
- *Correspondence: Fayez Bahmad Jr.
| |
Collapse
|
5
|
Van de Heyning P, Roland P, Lassaletta L, Agrawal S, Atlas M, Baumgartner WD, Brown K, Caversaccio M, Dazert S, Gstoettner W, Hagen R, Hagr A, Jablonski GE, Kameswaran M, Kuzovkov V, Leinung M, Li Y, Loth A, Magele A, Mlynski R, Mueller J, Parnes L, Radeloff A, Raine C, Rajan G, Schmutzhard J, Skarzynski H, Skarzynski PH, Sprinzl G, Staecker H, Stöver T, Tavora-Viera D, Topsakal V, Usami SI, Van Rompaey V, Weiss NM, Wimmer W, Zernotti M, Gavilan J. Suitable Electrode Choice for Robotic-Assisted Cochlear Implant Surgery: A Systematic Literature Review of Manual Electrode Insertion Adverse Events. Front Surg 2022; 9:823219. [PMID: 35402479 PMCID: PMC8987358 DOI: 10.3389/fsurg.2022.823219] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2021] [Accepted: 02/09/2022] [Indexed: 12/05/2022] Open
Abstract
Background and Objective The cochlear implant (CI) electrode insertion process is a key step in CI surgery. One of the aims of advances in robotic-assisted CI surgery (RACIS) is to realize better cochlear structure preservation and to precisely control insertion. The aim of this literature review is to gain insight into electrode selection for RACIS by acquiring a thorough knowledge of electrode insertion and related complications from classic CI surgery involving a manual electrode insertion process. Methods A systematic electronic search of the literature was carried out using PubMed, Scopus, Cochrane, and Web of Science to find relevant literature on electrode tip fold over (ETFO), electrode scalar deviation (ESD), and electrode migration (EM) from both pre-shaped and straight electrode types. Results A total of 82 studies that include 8,603 ears implanted with a CI, i.e., pre-shaped (4,869) and straight electrodes (3,734), were evaluated. The rate of ETFO (25 studies, 2,335 ears), ESD (39 studies, 3,073 ears), and EM (18 studies, 3,195 ears) was determined. An incidence rate (±95% CI) of 5.38% (4.4-6.6%) of ETFO, 28.6% (26.6-30.6%) of ESD, and 0.53% (0.2-1.1%) of EM is associated with pre-shaped electrodes, whereas with straight electrodes it was 0.51% (0.1-1.3%), 11% (9.2-13.0%), and 3.2% (2.5-3.95%), respectively. The differences between the pre-shaped and straight electrode types are highly significant (p < 0.001). Laboratory experiments show evidence that robotic insertions of electrodes are less traumatic than manual insertions. The influence of round window (RW) vs. cochleostomy (Coch) was not assessed. Conclusion Considering the current electrode designs available and the reported incidence of insertion complications, the use of straight electrodes in RACIS and conventional CI surgery (and manual insertion) appears to be less traumatic to intracochlear structures compared with pre-shaped electrodes. However, EM of straight electrodes should be anticipated. RACIS has the potential to reduce these complications.
Collapse
Affiliation(s)
- Paul Van de Heyning
- Department of Otorhinolaryngology Head and Neck Surgery, Antwerp University Hospital, University of Antwerp, Antwerp, Belgium
- Department of Translational Neurosciences, University of Antwerp, Antwerp, Belgium
| | - Peter Roland
- Department of Otolaryngology, Head & Neck Surgery, University of Texas Southwestern Medical Center, Dallas, TX, United States
| | - Luis Lassaletta
- Hospital Universitario La Paz, Institute for Health Research (IdiPAZ), Madrid, Spain
| | - Sumit Agrawal
- Department of Otolaryngology-Head and Neck Surgery, Western University, London, ON, Canada
| | - Marcus Atlas
- Ear Sciences Institute Australia, Lions Hearing Clinic, Perth, WA, Australia
| | | | - Kevin Brown
- UNC Ear and Hearing Center at Chapel Hill School of Medicine, Chapel Hill, NC, United States
| | - Marco Caversaccio
- Department for ENT, Head and Neck Surgery, Bern University Hospital, Bern, Switzerland
| | - Stefan Dazert
- Department of Otorhinolaryngology-Head and Neck Surgery, Ruhr-University Bochum, St. Elisabeth University Hospital Bochum, Bochum, Germany
| | | | - Rudolf Hagen
- Würzburg ENT University Hospital, Würzburg, Germany
| | - Abdulrahman Hagr
- King Abdullah Ear Specialist Center, King Saud University Medical City, King Saud University, Riyadh, Saudi Arabia
| | - Greg Eigner Jablonski
- Institute of Clinical Medicine, University of Oslo, Oslo, Norway
- Department of Otorhinolaryngology & Head and Neck Surgery, Oslo University Hospital, Rikshospitalet, Oslo, Norway
| | | | - Vladislav Kuzovkov
- St. Petersburg ENT and Speech Research Institute, St. Petersburg, Russia
| | - Martin Leinung
- Department of Otolaryngology, Head and Neck Surgery, University Hospital Frankfurt, Frankfurt am Main, Germany
| | - Yongxin Li
- Department of Otorhinolaryngology Head and Neck Surgery, Beijing Tongren Hospital, Capital Medical University, Beijing, China
- Key Laboratory of Otolaryngology Head and Neck Surgery (Capital Medical University), Ministry of Education, Beijing, China
| | - Andreas Loth
- Department of Otolaryngology, Head and Neck Surgery, University Hospital Frankfurt, Frankfurt am Main, Germany
| | - Astrid Magele
- Ear, Nose and Throat Department, University Clinic St. Poelten, Karl Landsteiner Private University, St. Poelten, Austria
| | - Robert Mlynski
- Department of Otorhinolaryngology, Head and Neck Surgery, “Otto Körner” Rostock University Medical Center, Rostock, Germany
| | - Joachim Mueller
- Klinik und Poliklinik für Hals-, Nasen- und Ohrenheilkunde, Ludwig-Maximilians-Universitat Munchen, Munchen, Germany
| | - Lorne Parnes
- Department of Otolaryngology-Head and Neck Surgery, Western University, London, ON, Canada
| | - Andreas Radeloff
- Division of Oto-Rhino-Laryngology, Evangelisches Krankenhaus Oldenburg, Research Center of Neurosensory Sciences, University Oldenburg, Oldenburg, Germany
| | - Chris Raine
- Bradford Royal Infirmary Yorkshire Auditory Implant Center, Bradford, United Kingdom
| | - Gunesh Rajan
- Department of Otolaryngology, Head and Neck Surgery, Luzerner Kantonsspital, Luzern, Medical Sciences Department of Health Sciences and Medicine. University of Lucerne, Luzern, Switzerland. Otolaryngology, Head & Neck Surgery, Medical School University of Western Australia, Perth, WA, Australia
| | - Joachim Schmutzhard
- Department of Otorhinolaryngology, Medical University of Innsbruck, Innsbruck, Austria
| | - Henryk Skarzynski
- Department of Teleaudiology and Screening, World Hearing Center of the Institute of Physiology and Pathology of Hearing, Kajetany, Poland
| | - Piotr H. Skarzynski
- Department of Teleaudiology and Screening, World Hearing Center of the Institute of Physiology and Pathology of Hearing, Kajetany, Poland
| | - Georg Sprinzl
- Ear, Nose and Throat Department, University Clinic St. Poelten, Karl Landsteiner Private University, St. Poelten, Austria
| | - Hinrich Staecker
- Kansas University Center for Hearing and Balance Disorders, Kansas City, KS, United States
| | - Timo Stöver
- Department of Otolaryngology, Head and Neck Surgery, University Hospital Frankfurt, Frankfurt am Main, Germany
| | | | - Vedat Topsakal
- Department of ENT HNS, University Hospital Brussels, Brussels, Belgium
| | - Shin-Ichi Usami
- Department of Hearing Implant Sciences, Shinshu University School of Medicine, Nagano, Japan
| | - Vincent Van Rompaey
- Department of Otorhinolaryngology Head and Neck Surgery, Antwerp University Hospital, University of Antwerp, Antwerp, Belgium
- Department of Translational Neurosciences, University of Antwerp, Antwerp, Belgium
| | - Nora M. Weiss
- Department of Otorhinolaryngology-Head and Neck Surgery, Ruhr-University Bochum, St. Elisabeth University Hospital Bochum, Bochum, Germany
| | - Wilhelm Wimmer
- Department for ENT, Head and Neck Surgery, Bern University Hospital, Bern, Switzerland
| | - Mario Zernotti
- Catholic University of Córdoba and National University of Córdoba, Córdoba, Argentina
| | - Javier Gavilan
- Hospital Universitario La Paz, Institute for Health Research (IdiPAZ), Madrid, Spain
| |
Collapse
|
6
|
Fan Y, Zhang D, Banalagay R, Wang J, Noble JH, Dawant BM. Hybrid active shape and deep learning method for the accurate and robust segmentation of the intracochlear anatomy in clinical head CT and CBCT images. J Med Imaging (Bellingham) 2021; 8:064002. [PMID: 34853805 DOI: 10.1117/1.jmi.8.6.064002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2020] [Accepted: 11/08/2021] [Indexed: 11/14/2022] Open
Abstract
Purpose: Robust and accurate segmentation methods for the intracochlear anatomy (ICA) are a critical step in the image-guided cochlear implant programming process. We have proposed an active shape model (ASM)-based method and a deep learning (DL)-based method for this task, and we have observed that the DL method tends to be more accurate than the ASM method while the ASM method tends to be more robust. Approach: We propose a DL-based U-Net-like architecture that incorporates ASM segmentation into the network. A quantitative analysis is performed on a dataset that consists of 11 cochlea specimens for which a segmentation ground truth is available. To qualitatively evaluate the robustness of the method, an experienced expert is asked to visually inspect and grade the segmentation results on a clinical dataset made of 138 image volumes acquired with conventional CT scanners and of 39 image volumes acquired with cone beam CT (CBCT) scanners. Finally, we compare training the network (1) first with the ASM results, and then fine-tuning it with the ground truth segmentation and (2) directly with the specimens with ground truth segmentation. Results: Quantitative and qualitative results show that the proposed method increases substantially the robustness of the DL method while having only a minor detrimental effect (though not significant) on its accuracy. Expert evaluation of the clinical dataset shows that by incorporating the ASM segmentation into the DL network, the proportion of good segmentation cases increases from 60/177 to 119/177 when training only with the specimens and increases from 129/177 to 151/177 when pretraining with the ASM results. Conclusions: A hybrid ASM and DL-based segmentation method is proposed to segment the ICA in CT and CBCT images. Our results show that combining DL and ASM methods leads to a solution that is both robust and accurate.
Collapse
Affiliation(s)
- Yubo Fan
- Vanderbilt University, Department of Computer Science, Nashville, Tennessee, United States
| | | | - Rueben Banalagay
- Vanderbilt University, Department of Electrical and Computer Engineering, Nashville, Tennessee, United States
| | - Jianing Wang
- Vanderbilt University, Department of Electrical and Computer Engineering, Nashville, Tennessee, United States
| | - Jack H Noble
- Vanderbilt University, Department of Electrical and Computer Engineering, Nashville, Tennessee, United States
| | - Benoit M Dawant
- Vanderbilt University, Department of Electrical and Computer Engineering, Nashville, Tennessee, United States
| |
Collapse
|
7
|
Abstract
OBJECTIVE The intracochlear position of an electrode array may influence the outcome after cochlear implantation. The design of the electrode array can increase the risk of trauma causing penetration of the basilar membrane or shift of the electrode array into the scala vestibuli. The aim of the present study was to identify a scalar shift after implantation of two different electrode arrays developed by one manufacturer. STUDY DESIGN Retrospective analysis. SETTING Tertiary referral center. PATIENTS AND INTERVENTION Cochlear implant recipients implanted between 2010 and 2014 and receiving either a mid-scala (n = 30) or a perimodiolar (n = 30) electrode array. MAIN OUTCOME MEASURE Occurrence of scalar shift in association with the electrode type. RESULTS Scalar shift occurred in 26.7% (8 of 30) of the patients implanted with a perimodiolar electrode array and in 6.7% (2 of 30) of the patients implanted with the mid-scala electrode array. The mean insertion depth in the patients experiencing scalar shift after implantation of the mid-scala electrode was much deeper (21.59 ± 0.34 mm) when compared with the mean insertion depth of the patients with scalar shift after implantation with a perimodiolar electrode array (17.85 ± 2.19 mm). There tends to be a correlation between the cochlear length and the occurrence of a scalar shift. However, the number of patients with scalar shift in the mid-scala group is rather small. CONCLUSION Based on the presented data, more patients implanted with a perimodiolar electrode array have a scalar shift when compared with the midscalar electrode array.
Collapse
|
8
|
Singh NK, Sinha S, Keshree NK, Kothari S, Kumar S, Kumar P. Relative efficacy of veria and mastoidectomy techniques of cochlear implantation in preservation of sound-induced saccular responses. Int J Audiol 2021; 60:858-866. [PMID: 33810782 DOI: 10.1080/14992027.2021.1905891] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
OBJECTIVE Cochlear implantation (CI) is a safe technique to give hearing sensation to a person with hearing impairment. The present study aimed to compare the two surgical approaches of CI, mastoidectomy and veria, for their effects on saccular function assessed using cervical vestibular-evoked myogenic potential (cVEMP). DESIGN Multiple group time series design. STUDY SAMPLE The study included 63 children (3-8 years old) who underwent CI using veria technique (n = 20) and mastoidectomy approach (n = 43). The 500-Hz tone-burst evoked cVEMP were recorded on three occasions- a day before CI surgery, a day after the device switch-on and 4 months after the switch-on. RESULTS The post-implant results revealed the absence of cVEMP in nearly 40% of the participants. The amplitudes were significantly lower at the time of the switch-on and at the 4-months follow-up period (p < 0.05). Among the participants undergoing CI using mastoidectomy approach, amplitudes were significantly larger after surgery than those undergoing surgery using veria technique (p < 0.05). CONCLUSIONS The saccular responses are better preserved with the mastoidectomy technique than the veria technique for CI surgery.
Collapse
Affiliation(s)
- Niraj Kumar Singh
- Department of Audiology, All India Institute of Speech and Hearing, Mysuru, India
| | - Sachchidanand Sinha
- Department of Speech and Hearing, Sri Aurobindo Institute of Medical Sciences and PG Institute, Indore, India
| | - Nirnay Kumar Keshree
- Department of Speech and Hearing, Sri Aurobindo Institute of Medical Sciences and PG Institute, Indore, India
| | - Shenal Kothari
- Department of ENT, Sri Aurobindo Institute of Medical Sciences and PG Institute, Indore, India
| | - Sudhir Kumar
- Department of Audiology, All India Institute of Speech and Hearing, Mysuru, India
| | - Prawin Kumar
- Department of Audiology, All India Institute of Speech and Hearing, Mysuru, India
| |
Collapse
|
9
|
Radiological evaluation of a new straight electrode array compared to its precursors. Eur Arch Otorhinolaryngol 2020; 278:3707-3714. [PMID: 33090276 PMCID: PMC8382647 DOI: 10.1007/s00405-020-06434-5] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2020] [Accepted: 10/10/2020] [Indexed: 11/24/2022]
Abstract
Objective The aim of this study is to examine electrode array coverage, scalar position and dislocation rate in straight electrode arrays with special focus on a new electrode array with 26 mm in lengths. Study design Retrospective study. Setting Tertiary academic center. Patients 201 ears implanted between 2013 and 2019. Main outcome measures We conducted a comparative analysis of patients implanted with lateral wall electrode arrays of different lengths (F24 = MED-EL Flex24, F26 = MED-EL Flex26, F28 = MED-EL Flex28 and F31.5 = MED-EL FlexSoft). Cone beam computed tomography was used to determine electrode array position (scala tympani (ST) versus scala vestibuli (SV), intracochlear dislocation, position of dislocation and insertion angle). Results Study groups show no significant differences regarding cochlear size which excludes influences by cochlear morphology. As expected, the F24 showed significant shorter insertion angles compared to the longer electrode arrays. The F26 electrode array showed no signs of dislocation or SV insertion. The electrode array with the highest rate of ST dislocations was the F31.5 (26.3%). The electrode array with the highest rates of SV insertions was the F28 (5.75%). Most of the included electrode arrays dislocate between 320° and 360° (mean: 346.4°; range from 166° to 502°). Conclusion The shorter F24 and the new straight electrode array F26 show less or no signs of scalar dislocation, neither for round window nor for cochleostomy insertion than the longer F28 and the F31.5 array. As expected, the cochlear coverage is increasing with length of the electrode array itself but with growing risk for scalar dislocation and with the highest rates of dislocation for the longest electrode array F31.5. Position of intracochlear dislocation is in the apical cochlear part in the included lateral wall electrode arrays.
Collapse
|
10
|
Abstract
OBJECTIVES Preservation of residual hearing is one of the main goals in present cochlear implantation surgery. Especially for this purpose, smaller and softer electrode carriers were developed that are to be inserted through the round window membrane to minimize trauma. By using these electrodes and insertion technique, residual hearing can be preserved in a large number of patients. Unfortunately, some of these patients with initially preserved residual hearing after cochlear implantation lose it later on. The reason for this is unknown but it is speculated about a correlation with an increase in impedance, since increased impedance values are linked to intracochlear inflammation and tissue reaction. Our hypothesis for this study design was that an increase in impedance predicts changes in residual hearing under clinical conditions. DESIGN Data of all adult patients (N = 122) receiving a Hybrid-L24 cochlear implant at our center between 2005 and early 2015 were retrospectively evaluated. Impedance values in Common Ground mode as measured during clinical routine and referring audiological test data (audiometric thresholds under headphones) were collected. Changes between consecutive measurements were calculated for impedance values and hearing thresholds for each patient. Correlations between changes in impedances and acoustic hearing thresholds were calculated. Average values were compared as well as patients with largest impedance changes within the observation period were evaluated separately. RESULTS Group mean values of impedances were between 5 and 7 kΩ and stable over time with higher values on basal electrode contacts compared with apical contacts. Average hearing thresholds at the time of initial fitting were between 40 to 50 dB (250 Hz) and 90 dB (1 kHz) with a loss of about 10 dB compared with preoperative values. Correlation between impedance changes and threshold changes was found, but too inconsistently to imply a true relationship. When evaluating the 20 patients with the largest impedance changes during the observation period (all >1 kΩ from one appointment to the next one), some patients were found where hearing loss is timely connected and highly correlated with an unusual impedance change. But large impedance changes were also observed without affecting hearing thresholds and hearing loss was found without impedance change. CONCLUSIONS Changes in impedance as measured during clinical routine cannot be taken as an indicator for a late acoustic hearing loss.
Collapse
|
11
|
Stock A, Bozzato V, Kloska SP, Bozzato A, Hoppe U, Hornung J, Dörfler A, Struffert T. Evaluation After Cochlear Implant Surgery : Correlation of Clinical Outcome and Imaging Findings using Flat-detector CT. Clin Neuroradiol 2020; 31:367-372. [PMID: 32556392 PMCID: PMC8410718 DOI: 10.1007/s00062-020-00922-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2020] [Accepted: 05/27/2020] [Indexed: 11/14/2022]
Abstract
Purpose Assessment of the cochlear implant (CI) electrode array position using flat-detector computed tomography (FDCT) to test dependence of postoperative outcome on intracochlear electrode position. Methods A total of 102 patients implanted with 107 CIs underwent FDCT. Electrode position was rated as 1) scala tympani, 2) scala vestibuli, 3) scalar dislocation and 4) no deconvolution. Two independent neuroradiologists rated all image data sets twice and the scalar position was verified by a third neuroradiologist. Presurgical and postsurgical speech audiometry by the Freiburg monosyllabic test was used to evaluate auditory outcome after 6 months of speech rehabilitation. Results Electrode array position was assessed by FDCT in 107 CIs. Of the electrodes 60 were detected in the scala tympani, 21 in the scala vestibuli, 24 electrode arrays showed scalar dislocation and 2 electrodes were not placed in an intracochlear position. There was no significant difference in rehabilitation outcomes between scala tympani and scala vestibuli inserted patients. Rehabilitation was also possible in patients with dislocated electrodes. Conclusion The use of FDCT is a reliable diagnostic method to determine the position of the electrode array. In our study cohort, the electrode position had no significant impact on postoperative outcome except for non-deconvoluted electrode arrays.
Collapse
Affiliation(s)
- Annika Stock
- Department of Neuroradiology, University Hospital Erlangen-Nuremberg, Erlangen, Germany. .,Department of Neuroradiology, University Hospital Würzburg, Josef-Schneider-Straße 11, 97080, Würzburg, Germany.
| | - Victoria Bozzato
- Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Saarland Medical School, Homburg, Germany
| | - Stephan P Kloska
- Department of Neuroradiology, University Hospital Erlangen-Nuremberg, Erlangen, Germany.,Department of Radiology, Hospital Fuerth, Fürth, Germany
| | - Alessandro Bozzato
- Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Saarland Medical School, Homburg, Germany
| | - Ulrich Hoppe
- Department of Otorhinolaryngology, Head & Neck Surgery, University of Erlangen-Nuremberg, Erlangen, Germany
| | - Joachim Hornung
- Department of Otorhinolaryngology, Head & Neck Surgery, University of Erlangen-Nuremberg, Erlangen, Germany
| | - Arnd Dörfler
- Department of Neuroradiology, University Hospital Erlangen-Nuremberg, Erlangen, Germany
| | - Tobias Struffert
- Department of Neuroradiology, University Hospital Erlangen-Nuremberg, Erlangen, Germany.,Department of Neuroradiology, University Hospital Gießen, Gießen, Germany
| |
Collapse
|
12
|
Jang JH, Kim H, Choo OS, Park HY, Choung YH. Changes in Vestibular Symptoms and Function After Cochlear Implantation: Relevant Factors and Correlations With Residual Hearing. Clin Exp Otorhinolaryngol 2020; 14:69-75. [PMID: 32526819 PMCID: PMC7904426 DOI: 10.21053/ceo.2019.01851] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2019] [Accepted: 03/05/2020] [Indexed: 11/22/2022] Open
Abstract
Objectives The aim of this study was to evaluate vestibular function loss after cochlear implantation (CI) and the relationship between vestibular function and hearing changes. Methods Seventy-five patients with CI were enrolled and divided into those with normal preoperative caloric function (group I) and those with a normal preoperative waveform in cervical vestibular evoked myogenic potential (c-VEMP) testing (group II). The relationship between hearing and changes in the vestibular system was analyzed preoperatively and at 3 and 6 months postoperatively. Results In group I, unilateral weakness on the implanted side was detected in five (7.7%) and eight (12.3%) patients at 3 and 6 months post-CI, respectively. By 3 months post-CI, the total slow-phase velocity (SPV; warm and cold stimulations) was significantly different between the implanted and non-implanted sides (P=0.011), and the shift in total SPV from pre- to post-CI was significantly correlated with the average hearing threshold at 6 months post-CI. In group II, an abnormal c-VEMP was detected on the implanted side in six patients (16.2%) at 3 months post-CI, and in six patients (16.2%) at 6 months post-CI. Significant changes were noticed in the P1 and N1 amplitude at 3 months postCI (P=0.027 and P=0.019, respectively). Conclusion Vestibular function and residual hearing function should be afforded equal and simultaneous consideration in terms of preservation.
Collapse
Affiliation(s)
- Jeong Hun Jang
- Department of Otorhinolaryngology, Ajou University School of Medicine, Suwon, Korea
| | - Hantai Kim
- Department of Otorhinolaryngology, Ajou University School of Medicine, Suwon, Korea
| | - Oak-Sung Choo
- Department of Otorhinolaryngology, Ajou University School of Medicine, Suwon, Korea
| | - Hun Yi Park
- Department of Otorhinolaryngology, Ajou University School of Medicine, Suwon, Korea
| | - Yun-Hoon Choung
- Department of Otorhinolaryngology, Ajou University School of Medicine, Suwon, Korea.,BK21 Plus Research Center for Biomedical Sciences, Ajou University Graduate School of Medicine, Suwon, Korea
| |
Collapse
|
13
|
Preservation of Vestibular Function and Residual Hearing After Round Window Cochlear Implantation. Otol Neurotol 2020; 40:878-882. [PMID: 31219963 DOI: 10.1097/mao.0000000000002257] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVE To examine the possible correlation between the loss of short-term residual hearing and vestibular function after cochlear implantation (CI). STUDY DESIGN Retrospective patient review. SETTING Academic tertiary referral center. PATIENTS One hundred twenty patients with normal vestibular function (VF) in the caloric testing and residual hearing (RH) at the frequencies 250, 500, and 1000 Hz on the surgery side between 2008 and 2016 were included in the study. INTERVENTION Primary CI on the first side via round window with a conventional full-length electrode. MAIN OUTCOME MEASURES Changes of RH and VF 7 weeks after surgery were analyzed. Preservation of RH was defined as measurable postoperative thresholds at the frequencies 250, 500, and 1000 Hz in the pure-tone audiogram. Preservation of the VF after CI was assessed both by an absolute and relative threshold in the caloric testing. RESULTS Seven weeks after implantation, the preservation of RH was achieved in 52 (43.3 %) patients and the preservation of VF in 95 (79.2 %) patients on the operated side. There was no significant statistical correlation between these two parameters. CONCLUSION The loss of RH was more than twice as frequent as the loss of VF. However, no statistical correlation between the failure of the two inner ear functions was found. The exact causes are still unknown, but our data could give an indication that there may be different underlying pathomechanisms.
Collapse
|
14
|
Ishiyama A, Risi F, Boyd P. Potential insertion complications with cochlear implant electrodes. Cochlear Implants Int 2020; 21:206-219. [PMID: 32079506 DOI: 10.1080/14670100.2020.1730066] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
Objectives: The aim of this discussion paper and literature review was to estimate the incidence of a variety of complications associated with the surgical placement of cochlear implant (CI) electrode arrays and to discuss the implications and management of sub-optimal electrode placement. Results: A review of the peer-reviewed literature suggests that the incidence of incomplete electrode insertion and kinking is more prevalent in straight arrays and not more than about 2% in CI recipients with normal cochlear anatomy/patency. Incidence of tip fold-over is greater with perimodiolar arrays but also occurs with straight arrays and is typically less than 5%. Conversely, electrode migration is more common with straight arrays, and high rates (up to 46%) have been reported in some studies. Scalar translocations have also been reported for both perimodiolar and straight arrays. Higher rates have been reported for stylet-based perimodiolar electrodes inserted via cochleostomy (up to 56%), but with much lower rates (<10%) with both sheath-based perimodiolar arrays and lateral wall arrays. Electrode positioning complications represent a significant proportion of perioperative CI complications and compromise the level of benefit from the device. Careful surgical planning and appropriate pre- and intraoperative imaging can reduce the likelihood and impact of electrode positioning complications. There is also evidence that newer array designs are less prone to certain complications, particularly scalar translocation. Conclusions: It is important that implanting surgeons are aware of the impact of sub-optimal electrode placement and the steps that can be taken to avoid, identify and manage such complications.
Collapse
Affiliation(s)
- Akira Ishiyama
- Rehabilitation Center, 1000 Veteran Ave., Los Angeles, CA, USA
| | - Frank Risi
- Clinical Affairs, Cochlear Ltd, Macquarie University, Sydney, Australia
| | - Paul Boyd
- Clinical Affairs, Cochlear Ltd, Macquarie University, Sydney, Australia
| |
Collapse
|
15
|
The Image Fusion Technique for Cochlear Implant Imaging: A Study of its Application for Different Electrode Arrays. Otol Neurotol 2019; 41:e216-e222. [PMID: 31834210 DOI: 10.1097/mao.0000000000002479] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVES To investigate the benefits of the image fusion technique for precise postoperative assessment of intracochlear placement with six different electrode arrays. STUDY DESIGN Consecutive retrospective case study. SETTINGS Tertiary referral center. PATIENTS Analyses of imaging data of 30 patients implanted with six different electrode arrays. INTERVENTIONS Electrode reconstructions obtained from postoperative cone-beam computed tomography (CBCT) were overlaid onto preoperative magnetic resonance imaging (MRI) and/or high-resolution computed tomography (HRCT) registrations to create artefact-free images. MAIN OUTCOME MEASURES Each electrode's intracochlear position was analyzed with the image fusion reconstructions and compared with the results obtained by CBCT alone. The electrode location was classified according to its position in relation to the basal membrane at four different insertion angles. RESULTS In 40 out of 151 measurements (26.5%), the location grading obtained by CBCT alone changed after the assessment with the image fusion reconstructions. A significant association was found between deep insertions (over 360 degrees) and the effectiveness of image fusion (p = 0.019). The difference between the impact of the fusion technique for the basal turn versus the apical part was highly significant (p = 0.001). There was no significant difference between the effectiveness of the image fusion and the different electrodes. CONCLUSIONS By utilizing an image fusion technique, a more accurate assessment of electrode placement could be achieved for all types of electrodes. Image fusion was especially beneficial for insertions beyond 360 degrees.
Collapse
|
16
|
Papathanasiou E, Straumann D. Why and when to refer patients for vestibular evoked myogenic potentials: A critical review. Clin Neurophysiol 2019; 130:1539-1556. [DOI: 10.1016/j.clinph.2019.04.719] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2015] [Revised: 04/08/2019] [Accepted: 04/22/2019] [Indexed: 12/13/2022]
|
17
|
Dhanasingh A, Jolly C. Review on cochlear implant electrode array tip fold-over and scalar deviation. J Otol 2019; 14:94-100. [PMID: 31467506 PMCID: PMC6712287 DOI: 10.1016/j.joto.2019.01.002] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2018] [Revised: 12/20/2018] [Accepted: 01/07/2019] [Indexed: 11/26/2022] Open
Abstract
Objective Determine the occurrence rate of cochlear implant (CI) electrode tip fold-over and electrode scalar deviation as reported in patient cases with different commercial electrode types. Data-sources PubMed search for identifying peer-reviewed articles published till 2018 on CI electrode tip fold-over and scalar deviation. Key-words for searching were “Cochlear electrode tip fold-over”, “Cochlear electrode scalar position” and “Cochlear electrode scalar location”. Articles-selection Only if electrode related issues were investigated in patient cases. 38 articles met the inclusion-criteria. Results 13 articles on electrode tip fold-over issue covering 3177 implanted ears, out of which 50 ears were identified with electrode tip fold-over with an occurrence rate of 1.57%. Out of 50 ears, 43 were implanted with pre-curved electrodes and the remaining 7 with lateral-wall electrodes. One article reported on both tip fold-over and scalar deviation. 26 articles reported on the electrode scalar deviation covering an overall number of 2046 ears out of which, 458 were identified with electrode scalar deviation at a rate of 22.38%. After removing the studies that did not report on the number of electrodes per electrode type, it was 1324 ears implanted with pre-curved electrode and 507 ears with lateral-wall electrode. Out of 1324 pre-curved electrode implanted ears, 424 were reported with scalar deviation making an occurrence rate of 32%. Out of 507 lateral-wall electrode implanted ears, 43 were associated with scalar deviation at an occurrence rate of 6.7%. Conclusion This literature review revealing the fact of higher rate of electrode insertion trauma associated with pre-curved electrode type irrespective of CI brand is one step closer to obsolete it from the clinical practice in the interest of patient's cochlear health.
Collapse
Affiliation(s)
| | - Claude Jolly
- MED-EL Medical Electronics GmbH, Innsbruck, Austria
| |
Collapse
|
18
|
Zhang D, Zhao Y, Noble JH, Dawant BM. Selecting electrode configurations for image-guided cochlear implant programming using template matching. J Med Imaging (Bellingham) 2017; 5:021202. [PMID: 29250568 DOI: 10.1117/1.jmi.5.2.021202] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2017] [Accepted: 08/16/2017] [Indexed: 11/14/2022] Open
Abstract
Cochlear implants (CIs) are neural prostheses that restore hearing using an electrode array implanted in the cochlea. After implantation, the CI processor is programmed by an audiologist. One factor that negatively impacts outcomes and can be addressed by programming is cross-electrode neural stimulation overlap (NSO). We have proposed a system to assist the audiologist in programming the CI that we call image-guided CI programming (IGCIP). IGCIP permits using CT images to detect NSO and recommend deactivation of a subset of electrodes to avoid NSO. We have shown that IGCIP significantly improves hearing outcomes. Most of the IGCIP steps are robustly automated but electrode configuration selection still sometimes requires manual intervention. With expertise, distance-versus-frequency curves, which are a way to visualize the spatial relationship learned from CT between the electrodes and the nerves they stimulate, can be used to select the electrode configuration. We propose an automated technique for electrode configuration selection. A comparison between this approach and one we have previously proposed shows that our method produces results that are as good as those obtained with our previous method while being generic and requiring fewer parameters.
Collapse
Affiliation(s)
- Dongqing Zhang
- Vanderbilt University, Department of Electrical Engineering and Computer Science, Nashville, Tennessee, United States
| | - Yiyuan Zhao
- Vanderbilt University, Department of Electrical Engineering and Computer Science, Nashville, Tennessee, United States
| | - Jack H Noble
- Vanderbilt University, Department of Electrical Engineering and Computer Science, Nashville, Tennessee, United States
| | - Benoit M Dawant
- Vanderbilt University, Department of Electrical Engineering and Computer Science, Nashville, Tennessee, United States
| |
Collapse
|
19
|
Electrode Location and Angular Insertion Depth Are Predictors of Audiologic Outcomes in Cochlear Implantation. Otol Neurotol 2017; 37:1016-23. [PMID: 27348391 DOI: 10.1097/mao.0000000000001125] [Citation(s) in RCA: 183] [Impact Index Per Article: 26.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES 1) Investigate the impact of electrode type and surgical approach on scalar electrode location; and 2) examine the relation between electrode location and postoperative audiologic performance. SETTING Tertiary academic hospital. PATIENTS Two hundred twenty post-lingually deafened adults undergoing cochlear implant (CI). MAIN OUTCOME MEASURES Primary outcome measures of interest were scalar electrode location and postoperative audiologic performance. RESULTS In 68% of implants, electrodes were observed to be located solely in the scala tympani (ST). Multivariate analysis demonstrated perimodiolar (PM) and mid-scala (MS) electrodes were 22.4 (95% CI: 6.3-80.0, p < 0.001) and 55.0 (95% CI: 9.7-312.8, p < 0.001) times more likely to have at least one electrode in the scala vestibuli (SV) compared with lateral wall (LW) electrodes, respectively. Compared with cochleostomy (C), round window (RW) and extended round window (ERW) approaches demonstrated 70% reduction in SV insertion (RW: OR 0.28, 95% CI: 0.1-0.8, p = 0.01; ERW: OR 0.28, 95% CI: 0.1-0.7, p = 0.005). Examining postoperative audiometric performance, consonant-nucleus-consonant (CNC) score increased 0.6% with every 10 degrees increase in angular insertion depth beyond the group minimum of 208 degrees (coefficient 0.0006, 95% CI: 0.0001-0.001, p = 0.03). SV insertion was associated with a 12% decrease in CNC score (coefficient -0.12, 95% CI: -0.22 to -0.02, p = 0.02). CNC score decreased 0.3% for every 1 year increase in age (coefficient -0.003, 95% CI: -0.006 to -0.0006, p = 0.02). CONCLUSIONS Electrode design and surgical approach were predictors of scalar electrode location. Specifically, LW electrodes showed higher rates of ST insertion compared with PM or MS. RW and ERW approaches showed higher rates of ST insertion when compared with C. In regards to performance, ST insertion, younger age, and greater angular insertion depth were predictors of improved CNC scores.
Collapse
|
20
|
Ibrahim I, da Silva SD, Segal B, Zeitouni A. Effect of cochlear implant surgery on vestibular function: meta-analysis study. J Otolaryngol Head Neck Surg 2017; 46:44. [PMID: 28595652 PMCID: PMC5465585 DOI: 10.1186/s40463-017-0224-0] [Citation(s) in RCA: 65] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2016] [Accepted: 05/26/2017] [Indexed: 11/10/2022] Open
Abstract
Importance Vestibular disorders have been reported following cochlear implant (CI) surgery, but the literature shows a wide discrepancy in the reported clinical impact. The aim of this meta-analysis is to quantify the effect of CI before and after surgery on the outcomes of vestibular tests, postural stability, and subjective perception of dizziness. Objective To evaluate the effects of CI surgery on vestibular function in adult patients (≥18 years) with sensorineural hearing loss who underwent unilateral or bilateral implantation. Data sources MEDLINE, PubMed, Web of Science and Cochrane Library from January 1, 1995, through July 12, 2016. Study selection Published studies of adult patients who received unilateral or bilateral CIs and whose vestibular function or postural stability was assessed before and after surgery. Data extraction From each study, test results before and after surgery were compared, for the following five tests: clinical head impulse test (HIT); bi-thermal caloric irrigation of the horizontal semicircular canal; vestibular evoked myogenic potential (VEMP); dizziness handicap inventory (DHI); and computerized dynamic posturography (CDP). Results Twenty-seven studies met all inclusion criteria. Most studies performed either bi-thermal caloric irrigation and/or VEMP, with fewer studies investigating changes in HIT, posturography or DHI. CI surgery significantly affected the results of caloric and VEMP testing. However, HIT results, posturography, and DHI, scores were not significantly affected after CI surgery. Conclusions and relevance CI surgery has a significant negative effect on the results of caloric as well as VEMP tests. No significant effect of CI surgery was detected in HIT, posturography, or DHI scores. Overall, the clinical effect of CI surgery on the vestibular function was found to be insignificant. Nonetheless, the potential effects of surgery on the vestibular system should be discussed with CI candidates before surgery.
Collapse
Affiliation(s)
- Iman Ibrahim
- Department of Otolaryngology-Head and Neck Surgery, Royal Victoria Hospital, McGill University, Montréal, Canada
| | - Sabrina Daniela da Silva
- Department of Otolaryngology-Head and Neck Surgery, Jewish General Hospital, McGill University, Montréal, Canada
| | - Bernard Segal
- Department of Otolaryngology-Head and Neck Surgery, Jewish General Hospital, McGill University, Montréal, Canada
| | - Anthony Zeitouni
- Department of Otolaryngology-Head and Neck Surgery, Royal Victoria Hospital, McGill University, Montréal, Canada.
| |
Collapse
|
21
|
Insertion Depth in Cochlear Implantation and Outcome in Residual Hearing and Vestibular Function. Ear Hear 2016; 37:e129-37. [PMID: 26524566 DOI: 10.1097/aud.0000000000000241] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES It has long been known that cochlear implantation may cause loss of residual hearing and vestibular function. Different insertion depths may cause varying degrees of intracochlear trauma in the apical region of the cochlea. The present study investigated the correlation between the insertion depth and postoperative loss of residual hearing and vestibular function. DESIGN Thirty-nine adults underwent unilateral cochlear implantation. One group received a Med-El +Flex electrode array (24 mm; n = 4), 1 group received a Med-El +Flex electrode array (28 mm; n = 18), and 1 group received a Med-El +Flex electrode array (31.5 mm; n = 17). Residual hearing, cervical vestibular-evoked myogenic potentials, videonystagmography, and subjective visual vertical/horizontal were explored before and after surgery. The electrode insertion depth and scalar position were examined with high-resolution rotational tomography after implantation in 29 subjects. RESULTS There was no observed relationship between the angular insertion depth (405° to 708°) and loss of low-frequency pure-tone average. Frequency-specific analysis revealed a weak relationship between the angular insertion depth and loss of hearing at 250 Hz (R= 0.20; p = 0.02). There was no statistically significant difference in the residual hearing and vestibular function between the +Flex and the +Flex electrode array. Eight percent of the cases had vertigo after surgery. The electrode arrays were positioned inside the scala tympani and not scala vestibuli in all subjects. In 18% of the cases, the +Flex electrode array was not fully inserted. CONCLUSIONS The final outcome in residual hearing correlates very weakly with the angular insertion depth for depths above 405°. Postoperative loss of vestibular function did not correlate with the angular insertion depth or age at implantation. The surgical protocol used in this study seems to minimize the risk of postoperative vertigo symptoms.
Collapse
|
22
|
O'Connell BP, Hunter JB, Wanna GB. The importance of electrode location in cochlear implantation. Laryngoscope Investig Otolaryngol 2016; 1:169-174. [PMID: 28894813 PMCID: PMC5510268 DOI: 10.1002/lio2.42] [Citation(s) in RCA: 90] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/20/2016] [Indexed: 11/29/2022] Open
Abstract
Objectives As indications for cochlear implantation have expanded to include patients with more residual hearing, increasing emphasis has been placed on minimally traumatic electrode insertion. Histopathologic evaluation remains the gold standard for evaluation of cochlear trauma, but advances in imaging techniques have allowed clinicians to determine scalar electrode location in vivo. This review will examine the relationship between scalar location of electrode arrays and audiologic outcomes. In addition, the impact that surgical approach, electrode design, and insertion depth have on scalar location will be evaluated. Data Sources: PubMed literature review Review Methods: A review of the current literature was conducted to analyze the relationship between scalar location of cochlear implant electrode arrays and speech perception outcomes. Further, data were reviewed to determine the impact that surgical variables have on scalar electrode location. Results Electrode insertions into the scala tympani are associated with superior speech perception and higher rates of hearing preservation. Lateral wall electrodes, and round window/extended round window approaches appear to maximize the likelihood of a scala tympani insertion. It does not appear that deeper insertions are associated with higher rates of scalar translocation. Conclusion Superior audiologic outcomes are observed for electrode arrays inserted entirely within the scala tympani. The majority of clinical data demonstrate that lateral wall design and a round window approach increase the likelihood of a scala tympani insertion. Level of Evidence N/A.
Collapse
Affiliation(s)
- Brendan P O'Connell
- Department of Otolaryngology-Head and Neck Surgery Vanderbilt University Medical Center Nashville Tennessee U.S.A
| | - Jacob B Hunter
- Department of Otolaryngology-Head and Neck Surgery Vanderbilt University Medical Center Nashville Tennessee U.S.A
| | - George B Wanna
- Department of Otolaryngology-Head and Neck Surgery Vanderbilt University Medical Center Nashville Tennessee U.S.A
| |
Collapse
|
23
|
Arts RAGJ, George ELJ, Griessner A, Zierhofer C, Stokroos RJ. Tinnitus Suppression by Intracochlear Electrical Stimulation in Single-Sided Deafness: A Prospective Clinical Trial - Part I. Audiol Neurootol 2015; 20:294-313. [PMID: 26227468 DOI: 10.1159/000381936] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2014] [Accepted: 03/28/2015] [Indexed: 11/19/2022] Open
Abstract
Cochlear implantation is a viable treatment option for tinnitus, but the underlying mechanism is yet unclear. Is the tinnitus suppression due to the reversal of the assumed maladaptive neuroplasticity or is it the shift in attention from the tinnitus to environmental sounds and therefore a reduced awareness that reduces tinnitus perception? In this prospective trial, 10 patients with single-sided deafness were fitted with a cochlear implant to investigate the effect of looped intracochlear electrical stimulation (i.e. stimulation that does not encode environmental sounds) on tinnitus, in an effort to find optimal stimulation parameters. Variables under investigation were: amplitude (perceived stimulus loudness), anatomical location inside the cochlea (electrode/electrodes), amplitude modulation, polarity (cathodic/anodic first biphasic stimulation) and stimulation rate. The results suggest that tinnitus can be reduced with looped electrical stimulation, in some cases even with inaudible stimuli. The optimal stimuli for tinnitus suppression appear to be subject specific. However, medium-to-loud stimuli suppress tinnitus significantly better than soft stimuli, which partly can be explained by the masking effect. Although the long-term effects on tinnitus would still have to be investigated and will be described in part II, intracochlear electrical stimulation seems a potential treatment option for tinnitus in this population.
Collapse
Affiliation(s)
- Remo A G J Arts
- Department of ENT/Head and Neck Surgery, Maastricht University Medical Centre, Maastricht, The Netherlands
| | | | | | | | | |
Collapse
|