Richardson G, Kivell MJ, Dunbar MJ, Laende EK. Tibial Slope Is Not Associated With Implant Migration Following Cemented Total Knee Arthroplasty With a Single Implant Design. J Arthroplasty 2024:S0883-5403(24)00333-4. [PMID: 38677348 DOI: 10.1016/j.arth.2024.04.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/17/2023] [Revised: 04/04/2024] [Accepted: 04/05/2024] [Indexed: 04/29/2024] Open
Abstract
BACKGROUND The influence of tibial slope on tibial component migration following total knee arthroplasty has not been widely studied, although excessive posterior slope has been implicated in some failures. As implant micromotion measured with radiostereometric analysis can indicate successful fixation, the purpose of this study was to determine the associations between tibial slope, tibial component migration, and inducible displacement. METHODS Radiostereometric analyses at 6 visits over 2 years quantified implant migration for 200 cemented total knee arthroplasties. Longitudinal data analysis examined the influence of postoperative tibial slope on implant migration (overall maximum total point motion (MTPM) migration and anterior-posterior tilt migration), accounting for age, sex, and body mass index. The correlations of tibial slope with 1-year migration, continuous migration, and inducible displacements were also examined. Additionally, the amount of change in slope was compared to migration. RESULTS The mean posterior tibial slope was 8.0° (standard deviation [SD] 3.8°) preoperatively and 3.8° (SD 3.1°) postoperatively, with a mean reduction in slope of 4.2° (SD 4.7°). Postoperative tibial slope (range 14.0° posterior slope to 3.4° anterior slope) was not associated with longitudinal overall migration (P = .671) or anterior-posterior tilt migration (P = .704). There was no association between postoperative tibial slope and migration at 1 year postoperatively (P = .441 for MTPM migration, P = .570 for tilt migration), change in migration from 1 to 2 years (P = .951), or inducible displacement (P = .970 MTPM, P = .730 tilt). The amount of change in tibial slope was also not associated with migration or inducible displacement. CONCLUSIONS Residual and change in postoperative tibial slope were not associated with implant migration into tilt or overall migration, or inducible displacement for a single implant design. These findings support positioning tibial implants in a range of slopes, which may support patient-specific approaches to implant alignment.
Collapse
Affiliation(s)
- Glen Richardson
- Division of Orthopaedics, Department of Surgery, Dalhousie University and QEII Health Sciences Centre, Nova Scotia Health Authority, Halifax, Nova Scotia, Canada
| | - Matthew J Kivell
- Division of Orthopaedics, Department of Surgery, Dalhousie University and QEII Health Sciences Centre, Nova Scotia Health Authority, Halifax, Nova Scotia, Canada
| | - Michael J Dunbar
- Division of Orthopaedics, Department of Surgery, Dalhousie University and QEII Health Sciences Centre, Nova Scotia Health Authority, Halifax, Nova Scotia, Canada
| | - Elise K Laende
- Division of Orthopaedics, Department of Surgery, Dalhousie University and QEII Health Sciences Centre, Nova Scotia Health Authority, Halifax, Nova Scotia, Canada; Mechanical and Materials Engineering, Queen's University, Kingston, Ontario, Canada
| |
Collapse
|
2
|
Polizzotti G, Lamberti A, Mancino F, Baldini A. New Horizons of Cementless Total Knee Arthroplasty. J Clin Med 2023; 13:233. [PMID: 38202240 PMCID: PMC10780266 DOI: 10.3390/jcm13010233] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2023] [Revised: 12/09/2023] [Accepted: 12/10/2023] [Indexed: 01/12/2024] Open
Abstract
BACKGROUND Considering the increasing number of young and active patients needing TKA, orthopedic surgeons are looking for a long-lasting and physiological bond for the prosthetic implant. Multiple advantages have been associated with cementless fixation including higher preservation of the native bone stock, avoidance of cement debris with subsequent potential third-body wear, and the achievement of a natural bond and osseointegration between the implant and the bone that will provide a durable and stable fixation. DISCUSSION Innovations in technology and design have helped modern cementless TKA implants to improve dramatically. Better coefficient of friction and reduced Young's modulus mismatch between the implant and host bone have been related to the use of porous metal surfaces. Moreover, biologically active coatings have been used on modern implants such as periapatite and hydroxyapatite. These factors have increased the potential for ingrowth by reducing micromotion and increasing osteoconductive properties. New materials with better biocompatibility, porosity, and roughness have been introduced to increase implant stability. CONCLUSIONS Innovations in technology and design have helped modern cementless TKA implants improve primary stability in both the femur and tibia. This means that short-term follow-up are comparable to cemented. These positive prognostic factors may lead to a future in which cementless fixation may be considered the gold-standard technique in young and active patients.
Collapse
Affiliation(s)
- Giuseppe Polizzotti
- Istituto Chirurgico Ortopedico Traumatologico (ICOT), Sapienza University of Rome, 00185 Rome, Italy
| | | | - Fabio Mancino
- University College London Hospital, London NW1 2BU, UK
- The Princess Grace Hospital, London W1U 5NY, UK
| | - Andrea Baldini
- Istituto Fiorentino di Cura e Assistenza, 50139 Florence, Italy
| |
Collapse
|
3
|
Puijk R, Rassir R, Sierevelt IN, Spekenbrink-Spooren A, Nelissen RGHH, Nolte PA. Association Between Surface Modifications for Biologic Fixation and Aseptic Loosening of Uncemented Total Knee Arthroplasties. J Arthroplasty 2023; 38:2605-2611.e1. [PMID: 37295622 DOI: 10.1016/j.arth.2023.05.094] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/27/2023] [Revised: 05/30/2023] [Accepted: 05/31/2023] [Indexed: 06/12/2023] Open
Abstract
BACKGROUND Various surface modifications are used in uncemented total knee arthroplasties (TKAs) to enhance bony ingrowth and longevity of implants. This study aimed to identify which surface modifications are used, whether they are associated with different revision rates for aseptic loosening, and which are underperforming compared to cemented implants. METHODS Data on all cemented and uncemented TKAs used between 2007 and 2021 were obtained from the Dutch Arthroplasty Register. Uncemented TKAs were divided into groups based on their surface modifications. Revision rates for aseptic loosening and major revisions were compared between groups. Kaplan-Meier, Competing-Risk, Log-rank tests, and Cox regression analyses were used. In total, 235,500 cemented and 10,749 uncemented primary TKAs were included. The different uncemented TKA groups included the following: 1,140 porous-hydroxyapatite (HA); 8,450 Porous-uncoated; 702 Grit-blasted-uncoated; and 172 Grit-blasted-Titanium-nitride (TiN) implants. RESULTS The 10-year revision rates for aseptic loosening and major revision of the cemented TKAs were 1.3 and 3.1%, and for uncemented TKAs 0.2 and 2.3% (porous-HA), 1.3 and 2.9% (porous-uncoated), 2.8 and 4.0% (grit-blasted-uncoated), and 7.9% and 17.4% (grit-blasted-TiN), respectively. Both type of revision rates varied significantly between the uncemented groups (log-rank tests, P < .001, P < .001). All grit-blasted implants had a significantly higher risk of aseptic loosening (P < .01), and porous-uncoated implants had a significantly lower risk of aseptic loosening than cemented implants (P = .03) after 10 years. CONCLUSION There were 4 main uncemented surface modifications identified, with different revision rates for aseptic loosening. Implants with porous-HA and porous-uncoated had the best revision rates, at least equal to cemented TKAs. Grit-blasted implants with and without TiN underperformed, possibly due to the interaction of other factors.
Collapse
Affiliation(s)
- Raymond Puijk
- Department of Orthopaedic Surgery, Spaarne Gasthuis, Hoofddorp, the Netherlands
| | - Rachid Rassir
- Department of Orthopaedic Surgery, Spaarne Gasthuis, Hoofddorp, the Netherlands
| | - Inger N Sierevelt
- Department of Orthopaedic Surgery, Spaarne Gasthuis, Hoofddorp, the Netherlands; Department of Orthopaedic Surgery, Xpert Clinics Orthopedie Amsterdam/Specialized Center of Orthopedic Research and Education, Amsterdam, the Netherlands
| | - Anneke Spekenbrink-Spooren
- Landelijke Registratie Orthopedische Interventies (LROI; Dutch Arthroplasty Register), Hertogenbosch, the Netherlands
| | - Rob G H H Nelissen
- Department of Orthopaedics, Leiden University Medical Center (LUMC), Leiden, the Netherlands
| | - Peter A Nolte
- Department of Orthopaedic Surgery, Spaarne Gasthuis, Hoofddorp, the Netherlands; Department of Oral Cell Biology, Academic Centre for Dentistry (ACTA), University of Amsterdam and Vrije Universiteit Amsterdam, Amsterdam, the Netherlands
| |
Collapse
|
4
|
Niesen AE, Hull ML. State of the Art in Radiostereometric Analysis for Tibial Baseplate Migration and Future Research Directions. J Biomech Eng 2023; 145:120801. [PMID: 37792485 DOI: 10.1115/1.4063626] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2023] [Accepted: 09/25/2023] [Indexed: 10/06/2023]
Abstract
Radiostereometric analysis (RSA) measures movement (migration) of a baseplate relative to the underlying tibia after total knee arthroplasty (TKA) and has been used extensively to evaluate safety of new implant designs and/or surgical techniques regarding baseplate loosening. Because RSA is a complex methodology which involves various choices that researchers make, including whether to use marker-based or model-based methods, which migration metric to report, how to relate short-term migrations to long-term risk, and how these choices impact error, the objectives of this review were to: (1) lay out a comprehensive structure illustrating the multiple components/considerations for RSA and their interrelations, (2) review components of the structure using the latest RSA literature, and (3) use the preceding review as a context for identifying future areas of study. The components to be reviewed were structured using the following topics: type of RSA, migration metrics, sources of error, studies/reports of error, stability limits, and studies of error in stability limits. Based on the current RSA literature and knowledge gaps which exist, the following future research directions were identified: (1) revising the ISO standard to require reporting of clinical measurement error (bias) and recommending use of a local baseplate coordinate system, (2) identifying the migration metric and associated threshold most predictive of baseplate loosening for individual patients, (3) creating a method for data sharing to improve individual patient diagnostics, and (4) determining an appropriate stability limit for model-based RSA for group stability and individual patient diagnostics.
Collapse
Affiliation(s)
- Abigail E Niesen
- Department of Biomedical Engineering, University of California, Davis, One Shields Avenue, Davis, CA 95616
| | - Maury L Hull
- Department of Biomedical Engineering, University of California, Davis, One Shields Avenue, Davis, CA 95616; Department of Mechanical Engineering, University of California, Davis, One Shields Avenue, Davis, CA 95616; Department of Orthopaedic Surgery, University of California Davis Medical Center, 4860 Y Street, Suite 3800, Sacramento, CA 95817
| |
Collapse
|
5
|
van der Lelij TJ, Marang-van de Mheen PJ, Kaptein BL, Toksvig-Larsen S, Nelissen RG. Continued Stabilization of a Cementless 3D-Printed Total Knee Arthroplasty: Five-Year Results of a Randomized Controlled Trial Using Radiostereometric Analysis. J Bone Joint Surg Am 2023; 105:1686-1694. [PMID: 37651549 PMCID: PMC10609712 DOI: 10.2106/jbjs.23.00221] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 09/02/2023]
Abstract
BACKGROUND Three-dimensional (3D) printing of highly porous orthopaedic implants aims to promote better osseointegration, thus preventing aseptic loosening. However, short-term radiostereometric analysis (RSA) after total knee arthroplasty (TKA) has shown higher initial migration of cementless 3D-printed tibial components compared with their cemented counterparts. Therefore, critical evaluation of longer-term tibial component migration is needed. We investigated migration of a cementless 3D-printed and a cemented tibial component with otherwise similar TKA design during 5 years of follow-up, particularly the progression in migration beyond 2 years postoperatively. METHODS Seventy-two patients were randomized to a cementless 3D-printed Triathlon Tritanium (Stryker) cruciate-retaining (CR) TKA or a cemented Triathlon CR (Stryker) TKA implant. Implant migration was evaluated with RSA at baseline and postoperatively at 3 months and at 1, 2, and 5 years. The maximum total point motion (MTPM) of the tibial component was compared between the groups at 5 years, and progression in migration was assessed between 2 and 5 years. Individual implants were classified as continuously migrating if the MTPM was ≥0.1 mm/year beyond 2 years postoperatively. Clinical scores were evaluated, and a linear mixed-effects model was used to analyze repeated measurements. RESULTS At 5 years, the mean MTPM was 0.66 mm (95% confidence interval [CI], 0.56 to 0.78 mm) for the cementless group and 0.53 mm (95% CI, 0.43 to 0.64 mm) for the cemented group (p = 0.09). Between 2 and 5 years, there was no progression in mean MTPM for the cementless group (0.02 mm; 95% CI, -0.06 to 0.10 mm) versus 0.07 mm (95% CI, 0.00 to 0.14) for the cemented group. One implant was continuously migrating in the cementless group, and 4 were continuously migrating in the cemented group. The clinical scores were comparable between the groups across the entire time of follow-up. CONCLUSIONS No significant difference in mean migration was found at 5 years between the cementless and cemented TKA implants. Progression of tibial component migration was present beyond 2 years for the cemented implant, whereas the cementless implant remained stable after initial early migration. LEVEL OF EVIDENCE Therapeutic Level I . See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
| | - Perla J. Marang-van de Mheen
- Medical Decision Making, Department of Biomedical Data Sciences, Leiden University Medical Center, Leiden, The Netherlands
| | - Bart L. Kaptein
- Department of Orthopaedics, Leiden University Medical Center, Leiden, The Netherlands
| | - Sören Toksvig-Larsen
- Department of Orthopaedics, Hässleholm Hospital, Hässleholm, Sweden
- Department of Clinical Sciences, Lund University, Lund, Sweden
| | - Rob G.H.H. Nelissen
- Department of Orthopaedics, Leiden University Medical Center, Leiden, The Netherlands
| |
Collapse
|
6
|
Fozo ZA, Hussein Ghazal A, Kamal I, Muhe Eldeen Eshag M, Elhady MM, Hesham Gamal M, Mohamed Fisal K, Ragab KM. A Systematic Review and Network Meta-Analysis of the Outcomes of Patients With Total Knee Arthroplasty Using Cemented, Uncemented, or Hybrid Techniques. Cureus 2023; 15:e47299. [PMID: 37869049 PMCID: PMC10589057 DOI: 10.7759/cureus.47299] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/18/2023] [Indexed: 10/24/2023] Open
Abstract
In this study, we aim to explore the differences among the three types of fixation methods for the components of the knee joint in patients who underwent total knee arthroplasty (TKA). These methods are cemented, uncemented, and hybrid fixation. Cemented fixation means that a special type of grout is used to attach the components to the bone. Uncemented fixation means that the components are designed to fit tightly into the bone and allow new bone growth to secure them. Hybrid fixation means that a combination of cemented and uncemented fixation is used for different components. We searched four online databases to find studies relevant to our research question. We use the R program (R Foundation for Statistical Computing, Vienna, Austria) for network meta-analysis (NMA) to analyze the data from the studies. We calculate the mean difference (MD) and the 95% confidence interval (CI) for each outcome, which are statistical measures of the difference and the uncertainty between methods. We use these measures for continuous outcomes, meaning they can have any value. For dichotomous outcomes, meaning they can only have two values, we use the risk ratio (RR) and the 95% CI, which are statistical measures of the relative risk and the uncertainty between methods. We assess the quality of randomized controlled trials, which are studies that randomly assign participants to different methods, using the Cochrane Risk of Bias Assessment Tool 1, a tool that evaluates the potential biases in the studies. We include 21 studies, and our analysis shows that cemented TKA reveals a statistically significant decrease in pain with hybrid TKA (MD = -2.82). That said, we find no significant differences between uncemented and cemented or hybrid (MD = -0.80 and -2.02, respectively). The results show that there is no significant difference between uncemented TKA and cemented TKA or hybrid technique (RR = 0.87, 95% CI 0.35-2.14; RR = 0.73, 95% CI 0.22-2.39, respectively). Also, we find no significant difference between cemented TKA and hybrid TKA (RR = 0.84, 95% CI 0.24-2.93). Cemented TKA is associated with a lower risk of deep vein thrombosis (DVT) incidence rate. Moreover, it shows a significant decrease in pain compared to hybrid TKA. Future research is needed to compare among the three interventions.
Collapse
Affiliation(s)
| | - Ahmed Hussein Ghazal
- Orthopaedics, Northwick Park Hospital, London North West University Healthcare NHS Trust, London, GBR
| | - Ibrahim Kamal
- General Medicine, Al-Azhar University, Alexandria, EGY
| | | | - Mahmoud M Elhady
- Orthopaedics, Faculty of Medicine, Benha University, Qalubiya, EGY
| | - Mohamed Hesham Gamal
- Pharmacology and Therapeutics, Faculty of Pharmacy, Tanta University, Elgharbia, EGY
| | - Khalid Mohamed Fisal
- Pharmacology and Therapeutics, Faculty of Pharmacy, Deraya University, Minia, EGY
| | | |
Collapse
|
7
|
Machado JKDS, Rodrigues BG, Silva LDD. Comparative Analysis of the Tibial Component Migration After Cemented and Uncemented Total Knee Arthroplasty with a Hydroxyapatite Coating in Two, Five, and Ten Years: A Meta-Analysis. Rev Bras Ortop 2023; 58:e544-e550. [PMID: 37663189 PMCID: PMC10468237 DOI: 10.1055/s-0043-1772194] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2022] [Accepted: 02/07/2023] [Indexed: 09/05/2023] Open
Abstract
Objective This study evaluated and compared the tibial component migration in cemented and uncemented total knee arthroplasty (TKA) with no hydroxyapatite coating 2, 5, and 10 years after surgery. Methods This meta-analysis followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) based on PubMed and MeSH database queries from June to July 2022. Results The meta-analysis included eight randomized clinical studies evaluating 668 knees undergoing TKA. The maximum total point motion (MTPM) in cemented TKAs was higher in 5 years, with a mean value of 0.67 mm (95% confidence interval [CI], 0.52 to 0.87). Uncemented TKAs also presented higher mean MTPM in 5 years (1 mm; 95% CI, 0.82 to 1.22). Uncemented coated ATKs had a higher mean MTPM in 10 years (1.30 mm; 95% CI, 0.70 to 2.39). MTPM was statistically similar in the short- and long-term for cemented and uncemented techniques, with a standardized mean difference of -0.65 (95% CI, -1.65 to 0.35). Conclusion Tibial component migration in TKA was statistically similar at 2, 5, and 10 years in cemented and uncemented techniques, either with or without coating. However, due to the scarce literature, further studies are required with a longer follow-up time.
Collapse
Affiliation(s)
- Jean Klay dos Santos Machado
- Médico Ortopedista, Coordenador do Serviço de Residência Médica do Serviço de Ortopedia e Traumatologia do Hospital Porto Dias, Belém, Pará, Brasil
| | | | - Laercio Dezinho da Silva
- Clínico Geral do Serviço de Ortopedia e Traumatologia do Hospital Porto Dias, Belém, Pará, Brasil
| |
Collapse
|
8
|
Kievit AJ, Buijs GS, Dobbe JGG, Ter Wee A, Kerkhoffs GMMJ, Streekstra GJ, Schafroth MU, Blankevoort L. Promising results of an non-invasive measurement of knee implant loosening using a loading device, CT-scans and 3D image analysis. Clin Biomech (Bristol, Avon) 2023; 104:105930. [PMID: 36906985 DOI: 10.1016/j.clinbiomech.2023.105930] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/25/2022] [Revised: 02/23/2023] [Accepted: 02/28/2023] [Indexed: 03/14/2023]
Abstract
BACKGROUND After total knee arthroplasty up to 13% requires revision surgery to address loosening. No current diagnostic modalities have a sensitivity or specificity higher than 70-80% to detect loosening, leading to 20-30% of patients undergoing unnecessary, risky and expensive revision surgery. A reliable imaging modality is required to diagnose loosening. This study presents a new and non-invasive method and evaluates its reproducibility and reliability in a cadaveric study. METHODS Ten cadaveric specimens were implanted with a loosely fitted tibial components and CT scanned under load towards valgus and varus using a loading device. Advanced three-dimensional imaging software was used to quantify displacement. Subsequently, the implants were fixed to the bone and scanned to determine the differences between the fixed and the loose state. Reproducibility errors were quantified using a frozen specimen in which displacement was absent. FINDINGS Reproducibility errors, expressed as mean target registration error, screw-axis rotation and maximum total point motion were 0.073 mm (SD 0.033), 0.129 degrees (SD 0.039) and 0.116 mm (SD 0.031), respectively. In the loose condition, all displacements and rotation changes were larger than the reported reproducibility errors. Comparing the mean target registration error, screw axis rotation and maximum total point motion in the loose condition to the fixed condition resulted in mean differences of 0.463 mm (SD 0.279; p = 0.001), 1.769 degrees (SD 0.868; p < 0.001) and 1.339 mm (SD 0.712; p < 0.001), respectively. INTERPRETATION The results of this cadaveric study show that this non-invasive method is reproducible and reliable for detection of displacement differences between fixed and loose tibial components.
Collapse
Affiliation(s)
- Arthur J Kievit
- Amsterdam UMC, location University of Amsterdam, Department of Orthopedic Surgery and Sport Medicine, Meibergdreef 9, Amsterdam, the Netherlands; Amsterdam Movement Sciences, Musculoskeletal Health, Meibergdreef 9, Amsterdam, the Netherlands
| | - George S Buijs
- Amsterdam UMC, location University of Amsterdam, Department of Orthopedic Surgery and Sport Medicine, Meibergdreef 9, Amsterdam, the Netherlands; Amsterdam Movement Sciences, Musculoskeletal Health, Meibergdreef 9, Amsterdam, the Netherlands.
| | - Johannes G G Dobbe
- Amsterdam UMC location University of Amsterdam, Department of Biomedical Engineering and Physics, Meibergdreef 9, Amsterdam, the Netherlands; Amsterdam Movement Sciences, Musculoskeletal Health, Meibergdreef 9, Amsterdam, the Netherlands
| | - Annemiek Ter Wee
- Amsterdam UMC location University of Amsterdam, Department of Biomedical Engineering and Physics, Meibergdreef 9, Amsterdam, the Netherlands; Amsterdam Movement Sciences, Musculoskeletal Health, Meibergdreef 9, Amsterdam, the Netherlands
| | - Gino M M J Kerkhoffs
- Amsterdam UMC, location University of Amsterdam, Department of Orthopedic Surgery and Sport Medicine, Meibergdreef 9, Amsterdam, the Netherlands; Amsterdam Movement Sciences, Musculoskeletal Health, Meibergdreef 9, Amsterdam, the Netherlands
| | - Geert J Streekstra
- Amsterdam UMC location University of Amsterdam, Department of Biomedical Engineering and Physics, Meibergdreef 9, Amsterdam, the Netherlands; Amsterdam Movement Sciences, Musculoskeletal Health, Meibergdreef 9, Amsterdam, the Netherlands
| | - Matthias U Schafroth
- Amsterdam UMC, location University of Amsterdam, Department of Orthopedic Surgery and Sport Medicine, Meibergdreef 9, Amsterdam, the Netherlands; Amsterdam Movement Sciences, Musculoskeletal Health, Meibergdreef 9, Amsterdam, the Netherlands
| | - Leendert Blankevoort
- Amsterdam UMC, location University of Amsterdam, Department of Orthopedic Surgery and Sport Medicine, Meibergdreef 9, Amsterdam, the Netherlands; Amsterdam Movement Sciences, Musculoskeletal Health, Meibergdreef 9, Amsterdam, the Netherlands
| |
Collapse
|
9
|
Laende EK, Mills Flemming J, Astephen Wilson JL, Cantoni E, Dunbar MJ. The associations of implant and patient factors with migration of the tibial component differ by sex : a radiostereometric study on more than 400 total knee arthroplasties. Bone Joint J 2022; 104-B:444-451. [PMID: 35360938 DOI: 10.1302/0301-620x.104b4.bjj-2021-1247.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AIMS Thresholds of acceptable early migration of the components in total knee arthroplasty (TKA) have traditionally ignored the effects of patient and implant factors that may influence migration. The aim of this study was to determine which of these factors are associated with overall longitudinal migration of well-fixed tibial components following TKA. METHODS Radiostereometric analysis (RSA) data over a two-year period were available for 419 successful primary TKAs (267 cemented and 152 uncemented in 257 female and 162 male patients). Longitudinal analysis of data using marginal models was performed to examine the associations of patient factors (age, sex, BMI, smoking status) and implant factors (cemented or uncemented, the size of the implant) with maximum total point motion (MTPM) migration. Analyses were also performed on subgroups based on sex and fixation. RESULTS In the overall group, only fixation was significantly associated with migration (p < 0.001). For uncemented tibial components in males, smoking was significantly associated with lower migration (p = 0.030) and BMI approached significance (p = 0.061). For females with uncemented components, smoking (p = 0.081) and age (p = 0.063) approached significance and were both associated with increased migration. The small number of self-reported smokers in this study warrants cautious interpretation and further investigation. For cemented components in females, larger sizes of tibial component were significantly associated with increased migration (p = 0.004). No factors were significant for cemented components in males. CONCLUSION The migration of uncemented tibial components was more sensitive to patient factors than cemented implants. These differences were not consistent by sex, suggesting that it may be of value to evaluate female and male patients separately following TKA. Cite this article: Bone Joint J 2022;104-B(4):444-451.
Collapse
Affiliation(s)
- Elise K Laende
- School of Biomedical Engineering, Dalhousie University, Halifax, Canada.,Division of Orthopaedics, Department of Surgery, Dalhousie University, Halifax, Canada.,Queen Elizabeth II Health Sciences Centre, Nova Scotia Health Authority, Halifax, Canada
| | | | - Janie L Astephen Wilson
- School of Biomedical Engineering, Dalhousie University, Halifax, Canada.,Department of Surgery, Dalhousie University, Halifax, Canada
| | - Eva Cantoni
- Research Center for Statistics and Geneva School of Economics and Management, University of Geneva, Geneva, Switzerland
| | - Michael J Dunbar
- School of Biomedical Engineering, Dalhousie University, Halifax, Canada.,Division of Orthopaedics, Department of Surgery, Dalhousie University, Halifax, Canada.,Queen Elizabeth II Health Sciences Centre, Nova Scotia Health Authority, Halifax, Canada
| |
Collapse
|
10
|
Hasan S, Kaptein BL, Nelissen RGHH, van Hamersveld KT, Toksvig-Larsen S, Marang-van de Mheen PJ. The Influence of Postoperative Coronal Alignment on Tibial Migration After Total Knee Arthroplasty in Preoperative Varus and Valgus Knees: A Secondary Analysis of 10 Randomized Controlled Trials Using Radiostereometric Analysis. J Bone Joint Surg Am 2021; 103:2281-2290. [PMID: 34648477 DOI: 10.2106/jbjs.20.01659] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Orthopaedic surgeons aim for mechanical alignment when performing total knee arthroplasty (TKA) as malalignment is associated with loosening. Loosening may be predicted by migration as measured with radiostereometric analysis (RSA), but previous RSA studies on postoperative alignment have shown contradictory results and have been limited to cemented implants and small numbers of patients. Therefore, we performed a secondary analysis of 10 previously published randomized controlled trials (RCTs) to compare migration between postoperative in-range and out-of-range cemented and uncemented TKA implants among patients with a preoperative varus or valgus knee. METHODS All RCTs involving the use of RSA that had been conducted at 2 centers were included. Alignment was classified, with use of the hip-knee-ankle angle (HKA), as in-range (0° ± 3°) or out-of-range (<-3° or >3°). The fixation methods included cemented, uncemented-coated, and uncemented-uncoated. Migration was measured at 3, 12, and 24 months. A linear mixed model was used, with adjustment for fixation method and clustering of patients within centers. RESULTS Of 476 TKA implants that had been out-of-range preoperatively, 290 were in-range postoperatively and 186 were out-of-range in either varus (n = 143) or valgus (n = 43) postoperatively. The mean migration at 3, 12, and 24 months was 0.73 mm (95% confidence interval [CI], 0.66 to 0.79 mm), 0.92 mm (95% CI, 0.85 to 1.00 mm), and 0.97 mm (95% CI, 0.90 to 1.05 mm), respectively, for the in-range group and 0.80 mm (95% CI, 0.72 to 0.87 mm), 0.98 (95% CI, 0.90 to 1.07 mm), and 1.04 mm (95% CI, 0.95 to 1.13 mm), respectively, for the out-of-range group (p = 0.07). The fixation method significantly influenced migration, with uncemented-uncoated implants migrating more than cemented and uncemented-coated implants (p < 0.001). CONCLUSIONS Postoperative alignment did not influence migration of TKAs in the first 2 postoperative years in patients with preoperative varus or valgus alignment of the knee. However, the fixation method significantly influenced migration, with uncemented-uncoated implants showing the greatest migration. LEVEL OF EVIDENCE Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Shaho Hasan
- Department of Orthopaedics, Leiden University Medical Center, Leiden, the Netherlands
| | - Bart L Kaptein
- Department of Orthopaedics, Leiden University Medical Center, Leiden, the Netherlands
| | - Rob G H H Nelissen
- Department of Orthopaedics, Leiden University Medical Center, Leiden, the Netherlands
| | - Koen T van Hamersveld
- Department of Orthopaedics, Leiden University Medical Center, Leiden, the Netherlands
| | - Sören Toksvig-Larsen
- Department of Orthopaedics, Hässleholm Hospital, Hässleholm, Sweden.,Department of Clinical Sciences, Lund University, Lund, Sweden
| | | |
Collapse
|
11
|
Chen C, Shi Y, Wu Z, Gao Z, Chen Y, Guo C, Bao X. Long-term effects of cemented and cementless fixations of total knee arthroplasty: a meta-analysis and systematic review of randomized controlled trials. J Orthop Surg Res 2021; 16:590. [PMID: 34641924 PMCID: PMC8513310 DOI: 10.1186/s13018-021-02762-2] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/14/2021] [Accepted: 09/30/2021] [Indexed: 11/21/2022] Open
Abstract
BACKGROUND To determine the long-term effects (a minimum follow-up time 8.8 years) of cemented and cementless fixations used for total knee arthroplasty (TKA). METHODS PubMed, EMBASE, Ovid, Cochrane Library, CINAHL, China National Knowledge Infrastructure and China Wangfang database were interrogated for appropriate randomized controlled trials (RCTs) through July 2020. Data were extracted and assessed for accuracy by 2 of the authors acting independently. Any controversial discrepancies were resolved after discussion with a third author. RESULT Eight RCTs were included with low to moderate bias risks. The cemented fixation of TKA was comparable to cementless fixation in terms of implant survival (relative risk, 1.016; 95% CI 0.978 to 1.056; P = 0.417), Knee Society (KS) knee score (standardized mean difference (SMD), - 0.107; 95% CI - 0.259 to 0.045; P = 0.168), KS function score (SMD - 0.065; 95% CI - 0.238 to 0.109; P = 0.463), KS pain score (SMD - 0.300; 95% CI - 0.641 to 0.042; P = 0.085), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score (SMD - 0.117; 95% CI - 0.307 to 0.073; P = 0.227), HSS score (SMD - 0.027; 95% CI - 0.270 to 0.217; P = 0.829), range of motion (SMD 0.061; 95% CI - 0.205 to 0.327; P = 0.652) at ≥ 8.8 years of follow-up. In terms of radiographic outcomes at ≥ 8.8 years of follow-up, the incidence of a radiolucent line in the cementless group was lower than for the cemented group (SMD 3.828; 95% CI 2.228 to 6.576; P < 0.001). However, the maximum total point motion (MTPM) of the cementless group was greater than for the cemented group (SMD - 0.739; 95% CI - 1.474 to - 0.005; P = 0.048). CONCLUSIONS Long-term follow-up verified that cementless and cemented fixation have similar prosthesis survival rates, clinical scores and mobility. However, radiography suggested that each technique had an advantage with regard to the radiolucent line and MTPM.
Collapse
Affiliation(s)
- Cheng Chen
- Department of Orthopedics, Nanjing Lishui People's Hospital, Zhongda Hospital Lishui Branch, Southeast University, No. 86 Chongwen Road, Lishui District, Nanjing, 211200, China
| | - Yanyan Shi
- Department of Geriatrics, Kong Jiang Hospital of Yangpu District, Shanghai, China
| | - Zhanpo Wu
- Department of Orthopedics, Nanjing Lishui People's Hospital, Zhongda Hospital Lishui Branch, Southeast University, No. 86 Chongwen Road, Lishui District, Nanjing, 211200, China.
| | - Zengxin Gao
- Department of Orthopedics, Nanjing Lishui People's Hospital, Zhongda Hospital Lishui Branch, Southeast University, No. 86 Chongwen Road, Lishui District, Nanjing, 211200, China.
| | - Youmin Chen
- Department of Orthopedics, Nanjing Lishui People's Hospital, Zhongda Hospital Lishui Branch, Southeast University, No. 86 Chongwen Road, Lishui District, Nanjing, 211200, China
| | - Changzheng Guo
- Department of Orthopedics, Nanjing Lishui People's Hospital, Zhongda Hospital Lishui Branch, Southeast University, No. 86 Chongwen Road, Lishui District, Nanjing, 211200, China
| | - Xianguo Bao
- Department of Orthopedics, Nanjing Lishui People's Hospital, Zhongda Hospital Lishui Branch, Southeast University, No. 86 Chongwen Road, Lishui District, Nanjing, 211200, China
| |
Collapse
|
12
|
van Hamersveld KT, Marang-van de Mheen PJ, Tsonaka R, Nilsson KG, Toksvig-Larsen S, Nelissen RGHH. Risk Factors for Tibial Component Loosening: A Meta-Analysis of Long-Term Follow-up Radiostereometric Analysis Data. J Bone Joint Surg Am 2021; 103:1115-1124. [PMID: 33886528 DOI: 10.2106/jbjs.20.01454] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Radiostereometric analysis (RSA) is a highly accurate tool to detect implant migration and predict loosening following total knee arthroplasty (TKA). However, little is known about the predisposing risk factors for implant migration, nor which migration profile should be considered physiological (i.e., merely part of an implant-settling phase) and which should be considered pathological (i.e., having a high probability for implant loosening). By pooling individual participant data from long-term follow-up RSA studies, we aimed to identify predisposing risk factors for tibial component loosening. METHODS Individual data were collected for 630 patients from 11 RSA studies. The repeated measurements were analyzed with use of a linear mixed-effects model, determining the effect of age, sex, body mass index, diagnosis, preoperative and postoperative limb alignment, and prosthesis characteristics on tibial component migration over time, taking into account the clustering of patients within studies. RESULTS High initial migration was found to result in early mechanical loosening in 18 cases (2.9%) and septic loosening in 2 cases (0.3%), whereas stabilization of high initial migration occurred in 17 cases (2.7%). Late loosening occurred in 13 cases (2.1%). All other 580 cases (92.1%) showed early stabilization and remained stable over time. Mixed-effects model analyses showed that for cemented prostheses, sex, diagnosis, and posterior cruciate ligament type had an effect on migration, but these differences were nonsignificant when analyzing migration from 3 months onwards. Uncemented prostheses aligned in varus showed more migration than neutrally and valgus-aligned TKAs (p = 0.031), and this difference increased over time (p < 0.001). Significantly higher migration was observed following uncemented TKA without an osseointegration-promoting surface (p < 0.001). CONCLUSIONS For cemented prostheses, increased migration during the first 3 postoperative months was observed for female patients, patients with rheumatoid arthritis, and patients who underwent a posterior-stabilized TKA. For uncemented prostheses, both postoperative varus alignment of the lower limb and the absence of an osseointegration-promoting surface significantly increased postoperative tibial component migration. LEVEL OF EVIDENCE Prognostic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Koen T van Hamersveld
- Departments of Orthopaedics (K.T.v.H. and R.G.H.H.N.) and Biomedical Data Sciences (P.J.M.-v.d.M. and R.T.), Leiden University Medical Center, Leiden, the Netherlands
| | - Perla J Marang-van de Mheen
- Departments of Orthopaedics (K.T.v.H. and R.G.H.H.N.) and Biomedical Data Sciences (P.J.M.-v.d.M. and R.T.), Leiden University Medical Center, Leiden, the Netherlands
| | - Roula Tsonaka
- Departments of Orthopaedics (K.T.v.H. and R.G.H.H.N.) and Biomedical Data Sciences (P.J.M.-v.d.M. and R.T.), Leiden University Medical Center, Leiden, the Netherlands
| | - Kjell G Nilsson
- Department of Surgical and Perioperative Sciences and Department of Orthopaedics, Umeå University, Umeå, Sweden
| | - Sören Toksvig-Larsen
- Department of Orthopaedics, Hässleholm Hospital, Hässleholm, Sweden.,Department of Clinical Sciences, Lund University, Lund, Sweden
| | - Rob G H H Nelissen
- Departments of Orthopaedics (K.T.v.H. and R.G.H.H.N.) and Biomedical Data Sciences (P.J.M.-v.d.M. and R.T.), Leiden University Medical Center, Leiden, the Netherlands
| |
Collapse
|
13
|
Laende EK, Richardson CG, Meldrum AR, Dunbar MJ. Tibial Component Migration After Total Knee Arthroplasty With High-Viscosity Bone Cement. J Arthroplasty 2021; 36:2000-2005. [PMID: 33632580 DOI: 10.1016/j.arth.2021.01.081] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/20/2020] [Revised: 01/11/2021] [Accepted: 01/29/2021] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND High-viscosity (HV) bone cements have been formulated to offer potentially advantageous handling characteristics. However, alteration in the handling characteristics could influence implant fixation and survival. The primary objective of this study was to use radiostereometric analysis after total knee arthroplasty to assess the migration of the Triathlon tibial component fixed with HV cement (Simplex HV). METHODS Twenty-three patients were followed for two years with radiostereometric analysis examinations at 6 visits. Migration was compared with published thresholds and with a control group from a previously published study from the same center using the same implants fixed with a medium viscosity cement. Inducible displacement was assessed, and Oxford 12 Knee Scores and satisfaction were recorded. RESULTS Mean maximum total point motion migration reaching 0.40 mm (SD 0.16) at one year, and 0.41mm (SD 0.17) at two years, demonstrating a pattern of stable fixation, below published thresholds of acceptable migration, and not significantly different from the control group. One implant had continuous migration between 1 and 2 years but was clinically asymptomatic. Mean maximum total point motion inducible displacement measured at least one year postoperatively was 0.3 mm (SD 0.12). Mean Oxford 12 Knee Scores improved from 19 (SD 7) preoperatively to 42 (SD 8) 2 years postoperatively. CONCLUSIONS The use of HV cement demonstrated an acceptable pattern of migration at 2 years, indicating low risk for aseptic loosening.
Collapse
Affiliation(s)
- Elise K Laende
- Division of Orthopaedics, Department of Surgery, Dalhousie University and QEII Health Sciences Centre, Nova Scotia Health Authority, Halifax, Nova Scotia, Canada; School of Biomedical Engineering, Faculty of Engineering & Faculty of Medicine, Dalhousie University, Halifax, Nova Scotia, Canada
| | - C Glen Richardson
- Division of Orthopaedics, Department of Surgery, Dalhousie University and QEII Health Sciences Centre, Nova Scotia Health Authority, Halifax, Nova Scotia, Canada
| | - Alexander R Meldrum
- Division of Orthopaedics, Department of Surgery, Dalhousie University and QEII Health Sciences Centre, Nova Scotia Health Authority, Halifax, Nova Scotia, Canada
| | - Michael J Dunbar
- Division of Orthopaedics, Department of Surgery, Dalhousie University and QEII Health Sciences Centre, Nova Scotia Health Authority, Halifax, Nova Scotia, Canada; School of Biomedical Engineering, Faculty of Engineering & Faculty of Medicine, Dalhousie University, Halifax, Nova Scotia, Canada
| |
Collapse
|
14
|
Van Der Voort P, D Klein Nulent ML, Valstar ER, Kaptein BL, Fiocco M, G H H Nelissen R. Long-term migration of a cementless stem with different bioactive coatings. Data from a "prime" RSA study: lessons learned. Acta Orthop 2020; 91:660-668. [PMID: 33143507 PMCID: PMC8023916 DOI: 10.1080/17453674.2020.1840021] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - Little is known about the long-term migration pattern of cementless stems in total hip arthroplasty (THA). Furthermore, the role of bioactive coatings in fixation, and thus migration, remains uncertain. Hydroxyapatite (HA) is the most commonly used bioactive coating. However, delamination of the coating might induce loosening. Alternatively, fluorapatite (FA) has proved to be more thermostable than HA, thereby potentially increasing longevity. We assessed the long-term migration of cementless stems with different coatings using radiostereometric analysis (RSA), thereby establishing a reference for acceptable migration. Patients and methods - 61 THAs in 53 patients were randomized to receive either a HA, FA, or uncoated Mallory-Head Porous stem during the years 1992 to 1994. Primary outcome was stem migration measured using RSA and secondary outcome was the Harris Hip Score (HHS). Evaluation took place preoperatively and postoperatively on the second day, at 6, 12, 25 and 52 weeks, and annually thereafter. At the 25-year follow-up, 12 patients (17 THAs) had died and 1 patient (1 THA) was lost to follow-up. Due to the high number of missing second-day postoperative RSA radiographs, the 1-year postoperative RSA radiograph was used as baseline for the comparative analyses. Results - Mean follow-up was 17 years (SD 6.6). All stems showed initial rapid migration with median subsidence of 0.2 mm (-0.1 to 0.6) and median retroversion of 0.9° (-3.2 to 2) at 12 months, followed by stable migration reaching a plateau phase. No stem was revised, albeit 1 stem showed continuous subsidence up to 1.5 mm. Comparing the different coatings, we could not find a statistically significant difference in overall 25-year migration (p-values > 0.05). Median subsidence at 15-year follow-up was for HA -0.1 mm (-0.4 to 0.2), for FA 0 mm (-0.1 to 0.2), and for uncoated stems 0.2 mm (-0.1 to 0.5). Median internal rotation at 15-year follow-up was for HA not available, for FA 1.1° (-0.5 to 2.6), and for uncoated stems 0° (-0.5 to 0.4). HHS were also comparable (p-values > 0.05), with at 15-year follow-up for HA 85 points (41-99), for FA 76 points (61-90), and for uncoated stems 79 points (74-90). Interpretation - The long-term migration pattern of cementless stems using different bioactive coatings has not previously been described. No beneficial effect, or side effect at long-term follow-up of bioactive coatings, was found. The provided migration data can be used in future research to establish thresholds for acceptable migration patterns cementless stem designs.
Collapse
Affiliation(s)
- Paul Van Der Voort
- Department of Orthopaedics, Leiden University Medical Center, Leiden; ,Correspondence:
| | | | - Edward R Valstar
- Department of Orthopaedics, Leiden University Medical Center, Leiden; ,Department of Biomechanical Engineering, Faculty of Mechanical, Maritime and Materials Engineering, University of Technology Delft, Delft;
| | - Bart L Kaptein
- Department of Orthopaedics, Leiden University Medical Center, Leiden;
| | - Marta Fiocco
- Department of Medical Statistics and Bioinformatics, Leiden University Medical Center, Leiden; ,Mathematical Institute, Leiden University, Leiden, The Netherlands
| | - Rob G H H Nelissen
- Department of Orthopaedics, Leiden University Medical Center, Leiden; ,Department of Biomechanical Engineering, Faculty of Mechanical, Maritime and Materials Engineering, University of Technology Delft, Delft;
| |
Collapse
|
15
|
Tarazi JM, Salem HS, Ehiorobo JO, Sodhi N, Mont MA, Harwin SF. Cementless Tritanium Baseplate Total Knee Arthroplasty: Survivorship and Outcomes at 5-Year Minimum Follow-Up. J Knee Surg 2020; 33:862-865. [PMID: 32559788 DOI: 10.1055/s-0040-1712983] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
BACKGROUND Newer generation cementless total knee arthroplasty (TKA) designs have provided stronger osteointegration between the implant and bone. Despite excellent survivorship and outcomes with cemented TKAs, areas of concern within the bone-cement interface remain a concern and necessitate studies on alternative constructs. This study assesses: (1) implant survivorship; (2) clinical outcomes; and (3) complications with radiographic outcomes at a 5-year minimum follow-up of cementless highly porous titanium-coated baseplates in TKAs. METHODS Part of this study has been reported. We retrospectively reviewed a prospectively collected database at a single high-volume institution between July 1, 2013 and June 30, 2014 for patients who underwent a primary TKA using cementless highly porous titanium-coated baseplate implants. Patients were evaluated clinically at postoperative follow-up visits at a minimum of 5 years. To calculate the survivorship, Kaplan-Meier analysis was performed to determine all-cause, aseptic, and septic implant survivorship at each final follow-up for all patients. RESULTS A total of 228 TKAs were performed and followed for a minimum of 5 years (range, 5-6 years). As of the latest follow-up, one case of septic loosening of the patellar button and one case of patellar dislodgment secondary to physical manipulation were recorded and revised. Overall, the cohort displayed implant survivorship of 99.5% at 5-year minimum follow-up. Improvements were seen in both Knee Society pain and function scores and were 37 points (range, 17-60 points) and 28 points (range, 15-47 points), respectively. The mean improvement in flexion was 17.8 (range, -20 to 40 degrees) and mean improvement in extension was -5.5 (range, -30 to 5 degrees). DISCUSSION Cementless TKAs serve as strong alternative choice to cemented TKAs. Although cemented fixation is commonly known as the gold standard, results of this study confirm the findings of previous investigations on the survivorship of cementless TKA implants. Therefore, patients who undergo primary TKA with a cementless tritanium baseplate can expect excellent clinical outcomes at a 5-year minimum follow-up.
Collapse
Affiliation(s)
- John M Tarazi
- Northwell Health Orthopaedics, Lenox Hill Hospital, New York, New York
| | - Hytham S Salem
- Northwell Health Orthopaedics, Lenox Hill Hospital, New York, New York
| | - Joseph O Ehiorobo
- Northwell Health Orthopaedics, Lenox Hill Hospital, New York, New York
| | - Nipun Sodhi
- Northwell Health Orthopaedics, Long Island Jewish Medical Center, New York, New York
| | - Michael A Mont
- Northwell Health Orthopaedics, Lenox Hill Hospital, New York, New York
| | - Steven F Harwin
- Department of Orthopaedics, Mount Sinai Hospital West, New York, New York
| |
Collapse
|
16
|
Hasan S, van Hamersveld KT, Marang-van de Mheen PJ, Kaptein BL, Nelissen RGHH, Toksvig-Larsen S. Migration of a novel 3D-printed cementless versus a cemented total knee arthroplasty: two-year results of a randomized controlled trial using radiostereometric analysis. Bone Joint J 2020; 102-B:1016-1024. [DOI: 10.1302/0301-620x.102b8.bjj-2020-0054.r1] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Aims Although bone cement is the primary mode of fixation in total knee arthroplasty (TKA), cementless fixation is gaining interest as it has the potential of achieving lasting biological fixation. By 3D printing an implant, highly porous structures can be manufactured, promoting osseointegration into the implant to prevent aseptic loosening. This study compares the migration of cementless, 3D-printed TKA to cemented TKA of a similar design up to two years of follow-up using radiostereometric analysis (RSA) known for its ability to predict aseptic loosening. Methods A total of 72 patients were randomized to either cementless 3D-printed or a cemented cruciate retaining TKA. RSA and clinical scores were evaluated at baseline and postoperatively at three, 12, and 24 months. A mixed model was used to analyze the repeated measurements. Results The mean maximum total point motion (MTPM) at three, 12, and 24 months was 0.33 mm (95% confidence interval (CI) 0.25 to 0.42), 0.42 mm (95% CI 0.33 to 0.51), and 0.47 mm (95% CI 0.38 to 0.57) respectively in the cemented group, versus 0.52 mm (95% CI 0.43 to 0.63), 0.62 mm (95% CI 0.52 to 0.73), and 0.64 mm (95% CI 0.53 to 0.75) in the cementless group (p = 0.003). However, using three months as baseline, no difference in mean migration between groups was found (p = 0.497). Three implants in the cemented group showed a > 0.2 mm increase in MTPM between one and two years of follow-up. In the cementless group, one implant was revised due to pain and progressive migration, and one patient had a liner-exchange due to a deep infection. Conclusion The cementless TKA migrated more than the cemented TKA in the first two-year period. This difference was mainly due to a higher initial migration of the cementless TKA in the first three postoperative months after which stabilization was observed in all but one malaligned and early revised TKA. Whether the biological fixation of the cementless implants will result in an increased long-term survivorship requires a longer follow-up. Cite this article: Bone Joint J 2020;102-B(8):1016–1024.
Collapse
Affiliation(s)
- Shaho Hasan
- Department of Orthopaedic Surgery, Leiden University Medical Centre, Leiden, Netherlands
| | - Koen T. van Hamersveld
- Department of Orthopaedic Surgery, Leiden University Medical Centre, Leiden, Netherlands
| | | | - Bart L. Kaptein
- Department of Orthopaedic Surgery, Leiden University Medical Centre, Leiden, Netherlands
| | | | - Sören Toksvig-Larsen
- Department of Orthopaedic Surgery, Hässleholm Hospital, Hässleholm, Sweden
- Department of Clinical Sciences, Lund University, Lund, Sweden
| |
Collapse
|
17
|
Horváth T, Hanák L, Hegyi P, Butt E, Solymár M, Szűcs Á, Varga O, Thien BQ, Szakács Z, Csonka E, Hartmann P. Hydroxyapatite-coated implants provide better fixation in total knee arthroplasty. A meta-analysis of randomized controlled trials. PLoS One 2020; 15:e0232378. [PMID: 32396538 PMCID: PMC7217427 DOI: 10.1371/journal.pone.0232378] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2019] [Accepted: 04/14/2020] [Indexed: 12/29/2022] Open
Abstract
BACKGROUND The potential advantages of hydroxyapatite (HA)-coated cementless total knee arthroplasty (TKA) implants are bone stock preservation and biological fixation. Studies comparing the outcomes of HA-coated cementless, non HA-coated cementless (uncemented) and cemented TKA implants reported contradictory data. Our aim was to provide a comparison of the effects of HA coating of tibial stem on the stability and functionality of TKA implants. METHODS A systematic literature search was performed using MEDLINE, Scopus, EMBASE and the CENTRAL databases up to May 31st, 2019. The primary outcome was Maximum Total Point Motion (MTPM) of the tibial stem. This parameter is determined by radiosterometric analysis and refers to the migration pattern of the prosthesis stems. The clinical outcomes of the implanted joints were evaluated by the Knee Society Knee Score (KSS) and the Knee Society Function Score (KFS). Weighted mean difference (WMD) with 95% confidence interval (CI) were calculated with the random-effects model. RESULTS Altogether, 11 randomized controlled trials (RCTs) with 902 patients for primary TKA implants were included. There was a statistically significant difference in the MTPM values with the use of HA-coated and uncoated uncemented implants (WMD = +0.28, CI: +0.01 to +0.56, P<0.001). However, HA-coated stems showed significantly higher migration when compared with the cemented prostheses (WMD = -0.29, CI: -0.41 to -0.16, P<0.001). The KSS values of HA-coated implants were significantly higher than those for the uncemented implants; moreover, KSS and KFS outcome scores were statistically not different between the HA-coated and cemented prosthesis cases. CONCLUSION HA-coating yields better stability than other, uncemented prostheses. More importantly, the HA-coating is not outperformed by cemented prosthesis in providing good functional outcome.
Collapse
Affiliation(s)
- Tamara Horváth
- Institute of Surgical Research, University of Szeged, Szeged, Hungary
| | - Lilla Hanák
- Institute for Translational Medicine, Medical School, University of Pécs, Pécs, Hungary
| | - Péter Hegyi
- Institute for Translational Medicine, Medical School, University of Pécs, Pécs, Hungary
| | - Edina Butt
- Department of Traumatology, University of Szeged, Szeged, Hungary
| | - Margit Solymár
- Institute for Translational Medicine, Medical School, University of Pécs, Pécs, Hungary
| | - Ákos Szűcs
- Department of Surgery, University of Semmelweis, Budapest, Hungary
| | - Orsolya Varga
- Department of Preventive Medicine, Faculty of Public Health, University of Debrecen, Debrecen, Hungary
| | - Bui Quoc Thien
- Department of Preventive Medicine, Faculty of Public Health, University of Debrecen, Debrecen, Hungary
| | - Zsolt Szakács
- Institute for Translational Medicine, Medical School, University of Pécs, Pécs, Hungary
- Szentágothai Research Centre, Medical School, University of Pécs, Pécs, Hungary
| | - Endre Csonka
- Department of Traumatology, University of Szeged, Szeged, Hungary
| | - Petra Hartmann
- Institute of Surgical Research, University of Szeged, Szeged, Hungary
| |
Collapse
|
18
|
Wojtowicz R, Henricson A, Nilsson KG, Crnalic S. Uncemented monoblock trabecular metal posterior stabilized high-flex total knee arthroplasty: similar pattern of migration to the cruciate-retaining design - a prospective radiostereometric analysis (RSA) and clinical evaluation of 40 patients (49 knees) 60 years or younger with 9 years' follow-up. Acta Orthop 2019; 90:460-466. [PMID: 31210081 PMCID: PMC6746276 DOI: 10.1080/17453674.2019.1626097] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - Uncemented monoblock cruciate retaining (CR) trabecular metal (TM) tibial components in total knee arthroplasty (TKA) work well in the long-term perspective in patients ≤ 60 years. Younger persons expect nearly normal knee flexion after TKA, but CR implants generally achieve less knee flexion compared with posterior stabilized (PS) implants. Cemented PS implants have higher revision rate than CR implants. Can an uncemented monoblock PS TM implant be used safely in younger patients? Patients and methods - 40 patients (49 knees) age ≤ 60 years with primary (20 knees) or posttraumatic osteoarthritis (OA) were operated with a high-flex TKA using an uncemented monoblock PS TM tibial component. Knees were evaluated with radiostereometric analysis (RSA) a mean 3 days (1-5) postoperatively, and thereafter at 6 weeks, 3 months, 1, 2, 5, and 9 years. Clinical outcome was measured with patient-related outcome measures (PROMs). Results - The implants showed a pattern of migration with initial large migration followed by early stabilization lasting up to 9 years, a pattern known to be compatible with good long-term results. Clinical and radiological outcome was excellent with 38 of the 40 patients being satisfied or very satisfied with the procedure and bone apposition to the entire implant surface in 46 of 49 knees. Mean knee flexion was 130°. 1 knee was revised at 3 months due to medial tibial condyle collapse. Interpretation - The uncemented monoblock PS TM implant works well in younger persons operated with TKA due to primary or secondary OA.
Collapse
Affiliation(s)
- Radoslaw Wojtowicz
- Department of Surgical and Perioperative Sciences, Umeå University, Umeå, Sweden;
| | | | - Kjell G Nilsson
- Department of Surgical and Perioperative Sciences, Umeå University, Umeå, Sweden; ,Correspondence:
| | - Sead Crnalic
- Department of Surgical and Perioperative Sciences, Umeå University, Umeå, Sweden;
| |
Collapse
|
19
|
Laende EK, Richardson CG, Dunbar MJ. A randomized controlled trial of tibial component migration with kinematic alignment using patient-specific instrumentation versus mechanical alignment using computer-assisted surgery in total knee arthroplasty. Bone Joint J 2019; 101-B:929-940. [PMID: 31362561 DOI: 10.1302/0301-620x.101b8.bjj-2018-0755.r3] [Citation(s) in RCA: 62] [Impact Index Per Article: 12.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
AIMS Patient-specific instrumentation of total knee arthroplasty (TKA) is a technique permitting the targeting of individual kinematic alignment, but deviation from a neutral mechanical axis may have implications on implant fixation and therefore survivorship. The primary objective of this randomized controlled study was to compare the fixation of tibial components implanted with patient-specific instrumentation targeting kinematic alignment (KA+PSI) versus components placed using computer-assisted surgery targeting neutral mechanical alignment (MA+CAS). Tibial component migration measured by radiostereometric analysis was the primary outcome measure (compared longitudinally between groups and to published acceptable thresholds). Secondary outcome measures were inducible displacement after one year and patient-reported outcome measures (PROMS) over two years. The secondary objective was to assess the relationship between alignment and both tibial component migration and inducible displacement. PATIENTS AND METHODS A total of 47 patients due to undergo TKA were randomized to KA+PSI (n = 24) or MA+CAS (n = 23). In the KA+PSI group, there were 16 female and eight male patients with a mean age of 64 years (sd 8). In the MA+CAS group, there were 17 female and six male patients with a mean age of 63 years (sd 7). Surgery was performed using cemented, cruciate-retaining Triathlon total knees with patellar resurfacing, and patients were followed up for two years. The effect of alignment on tibial component migration and inducible displacement was analyzed irrespective of study group. RESULTS There was no difference over two years in longitudinal migration of the tibial component between the KA+PSI and MA+CAS groups (reaching median maximum total point motion migration at two years of 0.40 mm for the KA+PSI group and 0.37 mm for the MA+CAS group, p = 0.82; p = 0.68 adjusted for age, sex, and body mass index (BMI) for all follow-ups). Both groups had mean migrations below acceptable thresholds. There was no difference in inducible displacement (p = 0.34) or PROMS (p = 0.61 for the Oxford Knee Score) between groups. There was no correlation between alignment and tibial component migration or alignment and inducible displacement. These findings support non-neutral alignment as a viable option with this component, with no evidence that it compromises fixation. CONCLUSION Kinematic alignment using patient-specific instrumentation in TKA was associated with acceptable tibial component migration, indicating stable fixation. These results are supportive of future investigations of kinematic alignment. Cite this article: Bone Joint J 2019;101-B:929-940.
Collapse
Affiliation(s)
- E K Laende
- Department of Surgery, Dalhousie University, Halifax, Canada.,QEII Health Sciences Centre, Nova Scotia Health Authority, Halifax, Canada
| | - C G Richardson
- Department of Surgery, Dalhousie University, Halifax, Canada.,QEII Health Sciences Centre, Nova Scotia Health Authority, Halifax, Canada
| | - M J Dunbar
- Department of Surgery, Dalhousie University, Halifax, Canada.,QEII Health Sciences Centre, Nova Scotia Health Authority, Halifax, Canada
| |
Collapse
|
20
|
Laende EK, Richardson CG, Dunbar MJ. Predictive value of short-term migration in determining long-term stable fixation in cemented and cementless total knee arthroplasties. Bone Joint J 2019; 101-B:55-60. [DOI: 10.1302/0301-620x.101b7.bjj-2018-1493.r1] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Aims Early implant migration measured with radiostereometric analysis (RSA) has been proposed as a useful predictor of long-term fixation of tibial components in total knee arthroplasty. Evaluation of actual long-term fixation is of interest for cemented components, as well as for cementless fixation, which may offer long-term advantages once osseointegration has occurred. The objective of this study was to compare the long-term migration with one- and two-year migration to evaluate the predictive ability of short-term migration data and to compare migration and inducible displacement between cemented and cementless (porous metal monoblock) components at least ten years postoperatively. Patients and Methods Patients who had participated in RSA migration studies with two-year follow-up were recruited to return for a long-term follow-up, at least ten years from surgery. Two cemented tibial designs from two manufacturers and one porous metal monoblock cementless tibial design were studied. At the long-term follow-up, patients had supine RSA examinations to determine migration and loaded examinations (single leg stance) to determine inducible displacement. In total, 79 patients (54 female) returned, with mean time since surgery of 12 years (10 to 14). There were 58 cemented and 21 cementless tibial components. Results Migration at one year and two years was significantly correlated with long-term migration (p < 0.001). Median migration at the long-term follow-up was 0.6 mm (maximum total point motion; interquartile range (IQR) 0.4 to 0.9) for the cemented group and 0.6 mm (IQR 0.3 to 1.1) for the cementless group with no difference between groups (p = 0.99). Inducible displacement was significantly lower for the cementless components (p < 0.001). Conclusion Long-term migration was strongly correlated with two-year migration. Although long-term migration was not different for cemented or cementless tibial components, inducible displacement at the long-term visit was significantly lower for these cementless components, suggesting superior fixation. These findings support the predictive value of short-term migration in determining long-term fixation. Cite this article: Bone Joint J 2019;101-B(7 Supple C):55–60
Collapse
Affiliation(s)
- E. K. Laende
- School of Biomedical Engineering, Dalhousie University, Halifax, Canada; Division of Orthopaedics, Department of Surgery, Dalhousie University and QEII Health Sciences Centre, Nova Scotia Health Authority, Halifax, Canada
| | - C. G. Richardson
- Division of Orthopaedics, Department of Surgery, Dalhousie University and QEII Health Sciences Centre, Nova Scotia Health Authority, Halifax, Canada
| | - M. J. Dunbar
- School of Biomedical Engineering, Dalhousie University, Halifax, Canada; Division of Orthopaedics, Department of Surgery, Dalhousie University and QEII Health Sciences Centre, Nova Scotia Health Authority, Halifax, Canada
| |
Collapse
|
21
|
Laende EK, Astephen Wilson JL, Mills Flemming J, Valstar ER, Richardson CG, Dunbar MJ. Equivalent 2-year stabilization of uncemented tibial component migration despite higher early migration compared with cemented fixation: an RSA study on 360 total knee arthroplasties. Acta Orthop 2019; 90:172-178. [PMID: 30669909 PMCID: PMC6461081 DOI: 10.1080/17453674.2018.1562633] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - Thresholds of implant migration for predicting long-term successful fixation of tibial components in total knee arthroplasty have not separated cemented and uncemented fixation. We compared implant migration of cemented and uncemented components at 1 year and as the change in migration from 1 to 2 years. Patients and methods - Implant migration of 360 tibial components measured using radiostereometric analysis was compared at 1 year and as the change in migration from 1 to 2 years in 222 cemented components (3 implant designs) and 138 uncemented components (5 implant designs). Results - 1-year maximum total point motion was lower for the cemented tibial components compared with the uncemented components (median = 0.31 mm [0.03-2.98] versus 0.63 mm [0.11-5.19] respectively, p < 0.001, mixed model). The change in migration from 1 to 2 years, however, was equivalent for cemented and uncemented components (mean [SD] 0.06 mm [0.19] and 0.07 mm [0.27] mm respectively, p = 0.6, mixed model). Interpretation - These findings suggest that current thresholds of acceptable migration at 1 year may be better optimized by considering cemented and uncemented tibial components separately as higher early migration of uncemented components was not associated with decreased stability from 1 to 2 years.
Collapse
Affiliation(s)
- Elise K Laende
- School of Biomedical Engineering, Dalhousie University, Halifax, Nova Scotia, Canada;; ,Division of Orthopaedics, Department of Surgery, Dalhousie University and QEII Health Sciences Centre, Nova Scotia Health Authority, Halifax, Nova Scotia, Canada;; ,Correspondence:
| | - Janie L Astephen Wilson
- School of Biomedical Engineering, Dalhousie University, Halifax, Nova Scotia, Canada;; ,Department of Surgery, Dalhousie University, Halifax, Nova Scotia, Canada;;
| | - Joanna Mills Flemming
- Department of Mathematics and Statistics, Dalhousie University, Halifax, Nova Scotia, Canada;;
| | - Edward R Valstar
- Department of Orthopedics, Leiden University Medical Center, Leiden, The Netherlands
| | - C Glen Richardson
- Division of Orthopaedics, Department of Surgery, Dalhousie University and QEII Health Sciences Centre, Nova Scotia Health Authority, Halifax, Nova Scotia, Canada;;
| | - Michael J Dunbar
- School of Biomedical Engineering, Dalhousie University, Halifax, Nova Scotia, Canada;; ,Division of Orthopaedics, Department of Surgery, Dalhousie University and QEII Health Sciences Centre, Nova Scotia Health Authority, Halifax, Nova Scotia, Canada;;
| |
Collapse
|
22
|
Henricson A, Wojtowicz R, Nilsson KG, Crnalic S. Uncemented or cemented femoral components work equally well in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 2019; 27:1251-1258. [PMID: 30361757 DOI: 10.1007/s00167-018-5227-5] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/25/2018] [Accepted: 10/17/2018] [Indexed: 01/22/2023]
Abstract
PURPOSE To study the pattern of migration and clinical results up to 10 years of uncemented versus cemented fixation of the femoral component in total knee arthroplasty. METHODS Randomized controlled trial was conducted of 41 patients (23 women, 18 men) under the age of 60 years using radiostereometric analysis. RESULTS About two-thirds of the cemented implants and half of the uncemented implants stabilized between 2 and 10 years, while the remainder displayed a small annual increase of maximum total point motion of 0.09-0.10 mm/year. At 10 years there were no statistically significant differences in migration or clinical results between the groups. CONCLUSION Uncemented fixation with titanium fiber mesh coating of the femoral component in total knee arthroplasty works equally as well as cemented fixation up to 10 years. An annual migration of 0.1 mm seems compatible with excellent long-term performance. LEVEL OF EVIDENCE I.
Collapse
Affiliation(s)
- Anders Henricson
- Department of Orthopaedics, Falu General Hospital, Falun, Sweden.
| | - Radek Wojtowicz
- Department of Surgical and Perioperative Sciences, Orthopaedics, Umeå University, Umeå, Sweden
| | - Kjell G Nilsson
- Department of Surgical and Perioperative Sciences, Orthopaedics, Umeå University, Umeå, Sweden
| | - Sead Crnalic
- Department of Surgical and Perioperative Sciences, Orthopaedics, Umeå University, Umeå, Sweden
| |
Collapse
|
23
|
Van Hamersveld KT, Marang-Van De Mheen PJ, Nelissen RGHH, Toksvig-Larsen S. Peri-apatite coating decreases uncemented tibial component migration: long-term RSA results of a randomized controlled trial and limitations of short-term results. Acta Orthop 2018; 89:425-430. [PMID: 29741133 PMCID: PMC6066768 DOI: 10.1080/17453674.2018.1469223] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
Background and purpose - Biological fixation of uncemented knee prostheses can be improved by applying hydroxyapatite coating around the porous surface via a solution deposition technique called Peri-Apatite (PA). The 2-year results of a randomized controlled trial, evaluating the effect of PA, revealed several components with continuous migration in the second postoperative year, particularly in the uncoated group. To evaluate whether absence of early stabilization is diagnostic of loosening, we now present long-term follow-up results. Patients and methods - 60 patients were randomized to PA-coated or uncoated (porous only) total knee arthroplasty of which 58 were evaluated with radiostereometric analysis (RSA) performed at baseline, at 3 months postoperatively and at 1, 2, 5, 7, and 10 years. A linear mixed-effects model was used to analyze the repeated measurements. Results - PA-coated components had a statistically significantly lower mean migration at 10 years of 0.94 mm (95% CI 0.72-1.2) compared with the uncoated group showing a mean migration of 1.72 mm (95% CI 1.4-2.1). Continuous migration in the second postoperative year was seen in 7 uncoated components and in 1 PA-coated component. All of these implants stabilized after 2 years except for 2 uncoated components. Interpretation - Peri-apatite enhances stabilization of uncemented components. The number of components that stabilized after 2 years emphasizes the importance of longer follow-up to determine full stabilization and risk of loosening in uncemented components with biphasic migration profiles.
Collapse
Affiliation(s)
| | | | | | - Sören Toksvig-Larsen
- Department of Orthopaedics, Hässleholm Hospital, Hässleholm, Sweden and Department of Clinical Sciences, Lund University, Lund, Sweden
| |
Collapse
|
24
|
Abstract
Purpose - We performed a systematic review and meta-analyses to evaluate the early and long-term migration patterns of tibial components of TKR of all known RSA studies. Methods - Migration pattern was defined as at least 2 postoperative RSA follow-up moments. Maximal total point motion (MTPM) at 6 weeks, 3 months, 6 months, 1 year, 2 years, 5 years, and 10 years were considered. Results - The literature search yielded 1,167 hits of which 53 studies were included, comprising 111 study groups and 2,470 knees. The majority of the early migration occurred in the first 6 months postoperatively followed by a period of stability, i.e., no or very little migration. Cemented and uncemented tibial components had different migration patterns. For cemented tibial components there was no difference in migration between all-poly and metal-backed components, between mobile bearing and fixed bearing, between cruciate retaining and posterior stabilized. Furthermore, no difference existed between TKR measured with model-based RSA or marker-based RSA methods. For uncemented TKR there was some variation in migration with the highest migration for uncoated TKR. Interpretation - The results from this meta-analysis on RSA migration of TKR are in line with both the survival analyses results from joint registries of these TKRs as well as revision rates results from meta-analyses, thus providing further proof for the association between early migration and late revision for loosening. The pooled migration patterns can be used both as benchmarks and for defining migration thresholds for future evaluation of new TKR.
Collapse
Affiliation(s)
- Bart G Pijls
- Department of Orthopaedics, Leiden University Medical Center, Leiden,Correspondence:
| | - José W M Plevier
- Walaeus Library, Leiden University Medical Center, Leiden, The Netherlands
| | | |
Collapse
|
25
|
Harwin SF, Levin JM, Khlopas A, Ramkumar PN, Piuzzi NS, Roche M, Mont MA. Cementless Posteriorly Stabilized Total Knee Arthroplasty: Seven-Year Minimum Follow-Up Report. J Arthroplasty 2018; 33:1399-1403. [PMID: 29195849 DOI: 10.1016/j.arth.2017.11.020] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/19/2017] [Revised: 10/21/2017] [Accepted: 11/08/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The purpose of this study is to evaluate (1) implant survivorship; (2) patient outcomes; (3) complications; and to (4) perform a radiographic analysis of cementless posteriorly stabilized total knee arthroplasty (TKA) patients at a minimum of 7-year follow-up. METHODS Our original cohort was composed of 114 consecutive cementless posteriorly stabilized total knee arthroplasties (110 patients) performed by a single surgeon between 2008 and 2010. Since our original report, 4 (1 bilateral) patients died and 2 were lost to follow-up. Therefore, there were 104 patients who had 107 knees available for final follow-up. The final cohort included 43 men and 61 women, who had a mean age of 69 years (range 47-87) and were followed from 7 to 9 years (mean 8 years). Patient outcomes and complications were obtained from electronic medical records. Radiographic assessment was done using the Knee Society Radiographic Evaluation System. RESULTS The all-cause survivorship was 98% (95% confidence interval 1.01-0.96). Since the original report, there has been 1 post-traumatic loosening of the tibial baseplate, and 1 revision for instability. There were no femoral revisions or patella revisions. The mean Knee Society pain score was 93 points (range 80-100) and the function score was 78 points (range 68-95). Excluding revisions, there was no evidence of progressive loosening of any implant components. CONCLUSION Based on these 7-year minimum follow-ups, femoral, tibial, and patellar cementless hydroxylapatite-coated beaded implants perform well at up to 9 years postoperatively and offer surgeons and patients a cementless option that may provide long-lasting biological fixation.
Collapse
Affiliation(s)
- Steven F Harwin
- Total Hip and Knee Arthroplasty Service, Department of Orthopaedic Surgery, Mount Sinai West, New York, New York
| | - Jay M Levin
- Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, Ohio
| | - Anton Khlopas
- Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, Ohio
| | - Prem N Ramkumar
- Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, Ohio
| | - Nicolas S Piuzzi
- Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, Ohio
| | - Martin Roche
- Department of Orthopaedic Surgery, Holy Cross Orthopedic Institute, Fort Lauderdale, Florida
| | - Michael A Mont
- Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, Ohio
| |
Collapse
|
26
|
Dunbar MJ, Laende EK, Collopy D, Richardson CG. Stable migration of peri-apatite-coated uncemented tibial components in a multicentre study. Bone Joint J 2017; 99-B:1596-1602. [PMID: 29212682 DOI: 10.1302/0301-620x.99b12.bjj-2016-1118.r2] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/03/2016] [Accepted: 07/10/2017] [Indexed: 11/05/2022]
Abstract
AIMS Hydroxyapatite coatings for uncemented fixation in total knee arthroplasty can theoretically provide a long-lasting biological interface with the host bone. The objective of this study was to test this hypothesis with propriety hydroxyapatite, peri-apatite, coated tibial components using component migration measured with radiostereometric analysis over two years as an indicator of long-term fixation. PATIENTS AND METHODS A total of 29 patients at two centres received uncemented PA-coated tibial components and were followed for two years with radiostereometric analysis exams to quantify the migration of the component. RESULTS While there was significant variation in individual migration patterns, the overall migration of the tibial component in the study group demonstrated a pattern of initial migration followed by stabilisation after one year, with mean maximum total point motion (MTPM) of 0.02 mm (standard deviation (sd) 0.20) between one and two years post-operatively. The direction of greatest motion was subsidence, which stabilised at three months post-operatively (mean translation of 0.21 mm, sd 0.40). CONCLUSION The tibial component migration pattern of stabilisation in the second post-operative year is indicative of successful long-term fixation for this PA-coated tibial component. Cite this article: Bone Joint J 2017;99-B:1596-1602.
Collapse
Affiliation(s)
- M J Dunbar
- Dalhousie University, Division of Orthopaedics, Department of Surgery, Dalhousie University, and Halifax Infirmary, QEII Health Sciences Centre, Nova Scotia Health Authority, 1796 Summer St, Halifax NS B3H 3A7, Canada
| | - E K Laende
- Halifax Infirmary, Division of Orthopaedics, Department of Surgery, Dalhousie University, and Halifax Infirmary, QEII Health Sciences Centre, Nova Scotia Health Authority, 1796 Summer St., Halifax NS B3H 3A7, Canada
| | - D Collopy
- Perth Hip and Knee Clinic, Suite 1/1 Wexford Street, Subiaco, Western Australia 6008, Australia
| | - C G Richardson
- Dalhousie University, Division of Orthopaedics, Department of Surgery, Dalhousie University, and Halifax Infirmary, QEII Health Sciences Centre, Nova Scotia Health Authority, 1796 Summer St., Halifax NS B3H 3A7, Canada
| |
Collapse
|
27
|
van Hamersveld KT, Marang-van de Mheen PJ, Tsonaka R, Valstar† ER, Toksvig-Larsen S. Fixation and clinical outcome of uncemented peri-apatite-coated versus cemented total knee arthroplasty. Bone Joint J 2017; 99-B:1467-1476. [DOI: 10.1302/0301-620x.99b11.bjj-2016-1347.r3] [Citation(s) in RCA: 38] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/19/2016] [Accepted: 06/26/2017] [Indexed: 11/05/2022]
Abstract
Aims The optimal method of tibial component fixation remains uncertain in total knee arthroplasty (TKA). Hydroxyapatite coatings have been applied to improve bone ingrowth in uncemented designs, but may only coat the directly accessible surface. As peri-apatite (PA) is solution deposited, this may increase the coverage of the implant surface and thereby fixation. We assessed the tibial component fixation of uncemented PA-coated TKAs versus cemented TKAs. Patients and Methods Patients were randomised to PA-coated or cemented TKAs. In 60 patients (30 in each group), radiostereometric analysis of tibial component migration was evaluated as the primary outcome at baseline, three months post-operatively and at one, two and five years. A linear mixed-effects model was used to analyse the repeated measurements. Results After five years of follow-up, one (cemented) component was revised due to ligament instability. Overall, uncemented PA-coated tibial components migrated significantly more (p = 0.003), with the mean maximum total point motion (MTPM) at five years being 0.62 mm (95% confidence intervals (CI) 0.49 to 0.76) for cemented tibial components and 0.97 mm (95% CI 0.81 to 1.15) for PA-coated tibial components in TKA. However, between three months and five years the cemented TKAs migrated significantly more (p = 0.02), displaying a MTPM of 0.27 mm (95% CI, 0.19 to 0.36) versus 0.13 mm (95% CI, 0.01 to 0.25) for PA-coated tibial components. One implant in each group was considered at risk for aseptic loosening due to continuous migration after five years of follow-up, albeit with different migration patterns for each group (i.e. higher initial migration but diminishing over time for the PA-coated component versus gradually increasing migration for the cemented component). Conclusion The tibial components of PA-coated TKAs showed more overall migration compared with the tibial components of cemented TKAs. However, post hoc analysis showed that this difference was caused by higher migration of PA-coated components in the first three months, after which a stable migration pattern was observed. Clinically, there was no significant difference in outcome between the groups. Cite this article: Bone Joint J 2017;99-B:1467–76.
Collapse
Affiliation(s)
- K. T. van Hamersveld
- Department of Orthopaedic Surgery, Leiden
University Medical Center, Post zone J11-R, P.O.
Box 9600, 2300 RC Leiden, The
Netherlands
| | - P. J. Marang-van de Mheen
- Department of Medical Decision Making,
Leiden University Medical Center, Post zone J10-S, P.O.
Box 9600, 2300 RC Leiden, The
Netherlands
| | - R. Tsonaka
- Department of Medical Statistics and BioInformatics,
Leiden University Medical Center, Post zone
S5-P, P.O. Box 9600, 2300
RC Leiden, The Netherlands
| | - E. R. Valstar†
- Department of Orthopaedic Surgery, Leiden
University Medical Center, Post zone J11-R, P.O.
Box 9600, 2300 RC Leiden, The
Netherlands
| | - S. Toksvig-Larsen
- Department of Orthopaedic Surgery, Hässleholm
Hospital and Department of Clinical Sciences, Lund University, P.O.
Box 351, 28125 Hässleholm, Sweden
and P.O. Box 117, 22100, Lund, Sweden
| |
Collapse
|
28
|
Good long-term results following cementless TKA with a titanium plasma coating. Knee Surg Sports Traumatol Arthrosc 2017; 25:2801-2808. [PMID: 26334884 DOI: 10.1007/s00167-015-3769-3] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/08/2015] [Accepted: 08/20/2015] [Indexed: 10/23/2022]
Abstract
PURPOSE While cemented total knee arthroplasty (TKA) is currently the gold standard for primary osteoarthritis, cementless component fixation has achieved increasingly comparable outcomes due to improvements in both implant designs and surgical technique. Long-term outcomes and survivorship with the TC-Plus cementless, titanium plasma-coated TKA system without patella resurfacing were evaluated. METHODS A homogenous population of 171 consecutive patients who received 206 primary TC-Plus TKAs without patella resurfacing over a 19-year period was retrospectively reviewed. Knee Society Clinical Rating System (KSCRS) scores were obtained, and radiographic evaluation was performed after a mean follow-up of 13.2 ± 8.4 years. Survivorship analysis was made with endpoints revision for any reason and aseptic loss of biological fixation. RESULTS One hundred and thirty-six TKAs implanted in 113 patients were available for analysis. Mean KSCRS clinical and functional scores improved significantly versus preoperative values. No radiological loss of biological fixation of femoral and tibial components was observed. Survival with aseptic revision of any component as the endpoint was 95.7 % (95 % confidence interval (CI) 91.7-97.9 %) and 93.6 % (95 % CI 87.8-96.6 %) at 10 and 15 years, respectively. CONCLUSION Titanium plasma-coated cementless TKA without patella resurfacing showed excellent long-term results, with high 10- and 15-year component survival rates. The clinical and radiological results were comparable to those of other cementless TKAs, providing further evidence for the non-cemented resurfacing of the osteoarthritic knee. LEVEL OF EVIDENCE IV.
Collapse
|
29
|
Outcomes of Newer Generation Cementless Total Knee Arthroplasty: Beaded Periapatite-Coated vs Highly Porous Titanium-Coated Implants. J Arthroplasty 2017; 32:2156-2160. [PMID: 28237217 DOI: 10.1016/j.arth.2017.01.044] [Citation(s) in RCA: 31] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/23/2016] [Revised: 01/05/2017] [Accepted: 01/25/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Newer generation cementless total knee arthroplasty (TKA) designs are available and have novel implant coatings. We evaluated and compared beaded periapatite (PA)-coated vs highly porous titanium-coated cementless TKAs. Specifically, we compared: (1) survivorship, (2) Knee Society Scores (KSSs) and range of motion, (3) complications, and (4) radiographic findings. METHODS There were 805 TKAs with beaded PA-coated tibial and patellar components (PA group; mean age 67 years; range 41-86 years), and 219 TKAs with highly porous titanium-coated tibial and patella components (mean age 66 years; range 34-88 years). Mean follow-up was 4.4 years (range 2-9 years; median 4 years). Implant survivorship was calculated using Kaplan-Meier curves. Student t-tests and chi-square tests were used as appropriate. Radiographic evaluation was performed using Knee Society Roentgenographic Evaluation and Scoring System. RESULTS All-cause implant survivorship in beaded PA-coated group was 99.5% (95% CI, 97.9%-99.9%) and 99.5% (95% CI, 92.7%-99.9%) in highly porous titanium-coated group. There were no significant differences in the KSS for pain and function. Improvement in flexion and extension was similar in the 2 groups. Overall, complication rate (2.2% vs 2.3%; P = .274) and number of revisions (6 [0.8%] vs 2 [0.2%]; P = .936) were similar in the 2 groups. Excluding the aseptic and septic failures, there were no progressive radiolucencies or osteolysis on radiographic evaluation. CONCLUSION This study has shown good clinical and patient-reported outcomes of cementless TKA for both implants. Future multicenter large scale clinical and cost-effectiveness studies are needed to determine the superiority of one cementless implant type over the other.
Collapse
|
30
|
Gudnason A, Adalberth G, Nilsson KG, Hailer NP. Tibial component rotation around the transverse axis measured by radiostereometry predicts aseptic loosening better than maximal total point motion. Acta Orthop 2017; 88:282-287. [PMID: 28266241 PMCID: PMC5434596 DOI: 10.1080/17453674.2017.1297001] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - Maximal total point motion (MTPM) measured by radiostereometry (RSA) is widely used as a predictor of total knee arthroplasty (TKA) loosening. We compared the ability of different RSA measurements at different time points to predict loosening of tibial TKA components in the long term. Patients and methods - 116 TKAs in 116 patients were included in our analysis. 16 (14.8-17.4) years after surgery, 5 tibial components had been revised due to aseptic loosening. Receiver operating characteristic curves were calculated in order to investigate the specificity and sensitivity of different RSA parameters at different thresholds. Results - Rotation around the transverse (x-) axis measured 2 years postoperatively had the best predictive value of all parameters, with an area under the curve (AUC) of 80%. Using a threshold of 0.8 degrees, a specificity of 85% and a sensitivity of 50% were reached. The AUC for tibial component distal translation was 79% and it was 77% for proximal translation, whereas it was only 68% for MTPM. Interpretation - Rotation of the cemented tibial component around the transverse axis, proximal translation, and distal translation are slightly better at predicting aseptic loosening than MTPM, and tibial component migration measured after 2 years gives a good prediction of aseptic loosening up to 15 years.
Collapse
Affiliation(s)
- Asgeir Gudnason
- Department of Orthopedics, Institute of Surgical Sciences, Uppsala University Hospital, Uppsala;,Correspondence:
| | - Gunnar Adalberth
- Department of Orthopedics, Institute of Surgical Sciences, Uppsala University Hospital, Uppsala
| | - Kjell-Gunnar Nilsson
- Department of Surgical and Perioperative Sciences, University of Umeå, Umeå, Sweden
| | - Nils P Hailer
- Department of Orthopedics, Institute of Surgical Sciences, Uppsala University Hospital, Uppsala
| |
Collapse
|
31
|
Outcomes of cementless unicompartmental and total knee arthroplasty: A systematic review. Knee 2017; 24:497-507. [PMID: 27923627 DOI: 10.1016/j.knee.2016.10.010] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/17/2016] [Revised: 10/14/2016] [Accepted: 10/19/2016] [Indexed: 02/02/2023]
Abstract
BACKGROUND Aseptic loosening is a common failure mode in cemented unicompartmental knee arthroplasty (UKA) and total knee arthroplasty (TKA). This led to the development of cementless designs but the historical outcomes were poor. Recent developments in cementless designs have improved outcomes, but the current status is unknown. Therefore, a systematic review was performed to assess recent outcomes of cementless knee arthroplasty. METHODS A search was performed using PubMed, Embase and Cochrane systems and national registries for studies reporting outcomes since 2005. Fifty-two cohort studies and four registries reported survivorship, failure modes or functional outcomes of cementless UKA and TKA. RESULTS Nine level I studies, six level II studies, three level III studies, 34 level IV studies and four registries were included. Three hundred eighteen failures in 10,309 cementless TKA procedures and 62 failures in 2218 cementless UKA procedures resulted in extrapolated five-year, 10-year and 15-year survivorship of cementless TKAs of 97.7%, 95.4% and 93.0%, respectively, and cementless UKA of 96.4%, 92.9% and 89.3%, respectively. Aseptic loosening was more common in cementless TKA (25%) when compared to UKA (13%). Functional outcomes of cementless TKA and UKA were excellent with 84.3% and 84.5% of the maximum possible scores, respectively. CONCLUSIONS This systematic review showed that good to excellent extrapolated survivorship and functional outcomes are seen following modern cementless UKA and TKA, with a low incidence of aseptic loosening following cementless UKA. LEVEL OF EVIDENCE Level IV.
Collapse
|
32
|
Abstract
Background and purpose - Total knee replacement (TKR) in younger patients using cemented components has shown inferior results, mainly due to aseptic loosening. Excellent clinical results have been reported with components made of trabecular metal (TM). In a previous report, we have shown stabilization of the TM tibial implants for up to 5 years. In this study, we compared the clinical and RSA results of these uncemented implants with those of cemented implants. Patients and methods - 41 patients (47 knees) aged ≤ 60 years underwent TKR. 22 patients (26 knees) received an uncemented monoblock cruciate-retaining (CR) tibial component (TM) and 19 patients (21 knees) received a cemented NexGen Option CR tibial component. Follow-up examination was done at 10 years, and 16 patients (19 knees) with TM tibial components and 17 patients (18 knees) with cemented tibial components remained for analysis. Results - 1 of 19 TM implants was revised for infection, 2 of 18 cemented components were revised for knee instability, and no revisions were done for loosening. Both types of tibial components migrated in the first 3 months, the TM group to a greater extent than the cemented group. After 3 months, both groups were stable during the next 10 years. Interpretation - The patterns of migration for uncemented TM implants and cemented tibial implants over the first 10 years indicate that they have a good long-term prognosis regarding fixation.
Collapse
Affiliation(s)
- Anders Henricson
- Department of Orthopaedics and Center for Clinical Research, Falu General Hospital, Falun;,Correspondence:
| | - Kjell G Nilsson
- Institution of Surgical and Perioperative Sciences, Department of Orthopaedics, Umeå University, Umeå, Sweden
| |
Collapse
|
33
|
Initial stability of a new cementless fixation method of a tibial component with polyaxial locking screws: a biomechanical in vitro examination. Arch Orthop Trauma Surg 2016; 136:1309-1316. [PMID: 27473204 DOI: 10.1007/s00402-016-2517-6] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/23/2015] [Indexed: 02/09/2023]
Abstract
INTRODUCTION Cementless fixation of the tibial component is critical as reduced initial stability leads to implant failure. In this experimental in vitro study, a new fixation method of the tibial component using polyaxial locking screws is evaluated using Roentgen stereophotogrammetric analysis (RSA). MATERIALS AND METHODS A special prototype of a tibial component with four polyaxial locking screws was tested on 10 fresh-frozen human tibia specimens. The components were tested with an axial load of 2000 N for 10,000 cycles. Radiographs in two views were performed before loading, after 1000 and after 10,000 cycles, respectively. Besides rotation and translation along the x-, y-, and z-axes, endpoints for RSA were maximum subsidence (MaxSub), maximum lift off (MaxLiftOff) and maximum total point motion (MTPM). RESULTS MaxSub increased from -0.5 mm (SD = 0.2) after 1000 cycles to -0.9 mm (SD = 1.1). MaxLiftOff was 0.1 mm after 1000 cycles and did not increase after 10,000 cycles. The MTPM was 0.7 mm (SD = 0.3) after 1000 cycles and 1.1 mm (SD = 1.1) after 10,000 cycles. Two out of nine implants showed an MTPM ≥ 1.0 mm after 10,000 cycles. CONCLUSIONS Polyaxial locking screws can potentially improve the initial stability of tibial components. The results of this study indicate that the use of such screws in total knee arthroplasty may be of interest in the future. Further experimental and clinical investigation is needed.
Collapse
|
34
|
Kendrick BJL, Kaptein BL, Valstar ER, Gill HS, Jackson WFM, Dodd CAF, Price AJ, Murray DW. Cemented versus cementless Oxford unicompartmental knee arthroplasty using radiostereometric analysis. Bone Joint J 2015; 97-B:185-91. [DOI: 10.1302/0301-620x.97b2.34331] [Citation(s) in RCA: 69] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
The most common reasons for revision of unicompartmental knee arthroplasty (UKA) are loosening and pain. Cementless components may reduce the revision rate. The aim of this study was to compare the fixation and clinical outcome of cementless and cemented Oxford UKAs. A total of 43 patients were randomised to receive either a cemented or a cementless Oxford UKA and were followed for two years with radiostereometric analysis (RSA), radiographs aligned with the bone–implant interfaces and clinical scores. The femoral components migrated significantly during the first year (mean 0.2 mm) but not during the second. There was no significant difference in the extent of migration between cemented and cementless femoral components in either the first or the second year. In the first year the cementless tibial components subsided significantly more than the cemented components (mean 0.28 mm (sd 0.17) vs. 0.09 mm (sd 0.19 mm)). In the second year, although there was a small amount of subsidence (mean 0.05 mm) there was no significant difference (p = 0.92) between cemented and cementless tibial components. There were no femoral radiolucencies. Tibial radiolucencies were narrow (< 1 mm) and were significantly (p = 0.02) less common with cementless (6 of 21) than cemented (13 of 21) components at two years. There were no complete radiolucencies with cementless components, whereas five of 21 (24%) cemented components had complete radiolucencies. The clinical scores at two years were not significantly different (p = 0.20). As second-year migration is predictive of subsequent loosening, and as radiolucency is suggestive of reduced implant–bone contact, these data suggest that fixation of the cementless components is at least as good as, if not better than, that of cemented devices. Cite this article: Bone Joint J 2015; 97-B:185–91.
Collapse
Affiliation(s)
| | - B. L. Kaptein
- Biomechanics and Imaging Group, Leiden
University Medical Center, PO Box 9600, 2300
RC Leiden, The Netherlands
| | - E. R. Valstar
- Biomechanics and Imaging Group, Leiden
University Medical Center, PO Box 9600, 2300
RC Leiden, The Netherlands
| | - H. S. Gill
- University of Bath, Claverton
Down, Bath BA2 7AY, UK
| | | | - C. A. F. Dodd
- NDORMS, University of Oxford, Windmill
Road, OX3 7LD, UK
| | - A. J. Price
- NDORMS, University of Oxford, Windmill
Road, OX3 7LD, UK
| | - D. W. Murray
- NDORMS, University of Oxford, Windmill
Road, OX3 7LD, UK
| |
Collapse
|
35
|
Barbadoro P, Ensini A, Leardini A, d'Amato M, Feliciangeli A, Timoncini A, Amadei F, Belvedere C, Giannini S. Tibial component alignment and risk of loosening in unicompartmental knee arthroplasty: a radiographic and radiostereometric study. Knee Surg Sports Traumatol Arthrosc 2014; 22:3157-62. [PMID: 24972998 DOI: 10.1007/s00167-014-3147-6] [Citation(s) in RCA: 61] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/11/2013] [Accepted: 06/18/2014] [Indexed: 11/25/2022]
Abstract
PURPOSE Unicompartmental knee arthroplasty (UKA) has shown a higher rate of revision compared with total knee arthroplasty. The success of UKA depends on prosthesis component alignment, fixation and soft tissue integrity. The tibial cut is the crucial surgical step. The hypothesis of the present study is that tibial component malalignment is correlated with its risk of loosening in UKA. METHODS This study was performed in twenty-three patients undergoing primary cemented unicompartmental knee arthroplasties. Translations and rotations of the tibial component and the maximum total point motion (MTPM) were measured using radiostereometric analysis at 3, 6, 12 and 24 months. Standard radiological evaluations were also performed immediately before and after surgery. Varus/valgus and posterior slope of the tibial component and tibial-femoral axes were correlated with radiostereometric micro-motion. A survival analysis was also performed at an average of 5.9 years by contacting patients by phone. RESULTS Varus alignment of the tibial component was significantly correlated with MTPM, anterior tibial sinking, varus rotation and anterior and medial translations from radiostereometry. The posterior slope of the tibial component was correlated with external rotation. The survival rate at an average of 5.9 years was 89%. The two patients who underwent revision presented a tibial component varus angle of 10° for both. CONCLUSIONS There is correlation between varus orientation of the tibial component and MTPM from radiostereometry in unicompartmental knee arthroplasties. Particularly, a misalignment in varus larger than 5° could lead to risk of loosening the tibial component. LEVEL OF EVIDENCE Prognostic studies-retrospective study, Level II.
Collapse
Affiliation(s)
- P Barbadoro
- 1st Ortopaedic-Traumatologic Clinic, Istituto Ortopedico Rizzoli, University of Bologna, Via Pupilli 1, 40136, Bologna, Bo, Italy,
| | | | | | | | | | | | | | | | | |
Collapse
|
36
|
Abram SGF, Marsh AG, Brydone AS, Nicol F, Mohammed A, Spencer SJ. The effect of tibial component sizing on patient reported outcome measures following uncemented total knee replacement. Knee 2014; 21:955-9. [PMID: 25017484 DOI: 10.1016/j.knee.2014.05.010] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/01/2014] [Revised: 05/20/2014] [Accepted: 05/22/2014] [Indexed: 02/02/2023]
Abstract
UNLABELLED When performing total knee replacement (TKR), surgeons are required to decide on the most appropriate size of tibial component. As implants are predominantly selected from incremental sizes of a preferred design, it may be necessary for a surgeon to slightly under or oversize the component. There are concerns that overhang could lead to pain from irritation of soft tissues, and an undersized component could lead to subsidence and failure. Patient reported outcome measures were recorded in 154 TKRs at one year postoperatively (in 100 TKRs) and five years post-operatively (in 54 TKRs) in 138 patients. The Oxford Knee Score (OKS), WOMAC and SF-12 were recorded, and a composite pain score was derived from the OKS and WOMAC pain questions. Tibial component size and position were assessed on scaled radiographs and implants were grouped into anatomic sized tibial component (78 TKRs), undersized component (48 TKRs), minor overhang one to three mm (10 TKRs) or major overhang ≥ 3 mm (18 TKRs). There was no statistically significant difference between the mean post-operative OKS, WOMAC, SF-12 or composite pain score of each group. Furthermore, localisation of the site of pain did not correlate with medial or lateral overhang of the tibial component. Our results suggest that tibial component overhang or undersizing is not detrimental to outcome measures or pain. LEVEL OF EVIDENCE II.
Collapse
Affiliation(s)
- Simon G F Abram
- Department of Orthopaedics, Southern General Hospital, 1345 Govan Road, Glasgow G51 4TF, United Kingdom.
| | - Andrew G Marsh
- Department of Orthopaedics, Southern General Hospital, 1345 Govan Road, Glasgow G51 4TF, United Kingdom
| | - Alistair S Brydone
- Department of Orthopaedics, Southern General Hospital, 1345 Govan Road, Glasgow G51 4TF, United Kingdom
| | - Fiona Nicol
- Department of Orthopaedics, Southern General Hospital, 1345 Govan Road, Glasgow G51 4TF, United Kingdom
| | - Aslam Mohammed
- Department of Orthopaedics, Southern General Hospital, 1345 Govan Road, Glasgow G51 4TF, United Kingdom
| | - Simon J Spencer
- Department of Orthopaedics, Southern General Hospital, 1345 Govan Road, Glasgow G51 4TF, United Kingdom
| |
Collapse
|
37
|
Long lasting outcome of hydroxyapatite-coated implants in primary knee arthroplasty: a continuous series of two hundred and seventy total knee arthroplasties at fifteen to twenty two years of clinical follow-up. INTERNATIONAL ORTHOPAEDICS 2014; 38:305-11. [PMID: 24382665 DOI: 10.1007/s00264-013-2246-1] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/29/2013] [Accepted: 12/01/2013] [Indexed: 10/25/2022]
Abstract
PURPOSE This study is a long-term review of an hydroxyapatite (HA)-coated knee prosthesis. Our aim was to confirm that excellent previously reported results with HA knees could stand the test of time at the 15-year milestone. METHODS A total of 270 cruciate retaining HA-Omnifit knees, implanted in the same institution by a single surgeon with the same surgical procedure, were reviewed at 15-22 years of clinical follow-up (75 knees partially-coated and 195 fully-coated). RESULTS At review, IKS mean values were 95.6 points for knee score and 91.19 points for function score. Radiological review confirmed an excellent long-lasting fixation over years in the long run. Taking implant failure as the end-point, the survival rate was 97.1% at 20 years. CONCLUSIONS Our results were as good, and often better, than the best cemented or porous published studies. These very encouraging results at 15-22 years make us very confident in the ultimate outcome of bioconductive coatings in knee arthroplasty.
Collapse
|
38
|
Abstract
As a result of reading this article, physicians should be able to :1. Understand the rationale behind using uncemented fixation in total knee arthroplasty.2.Discuss the current literature comparing cemented and uncemented total knee arthroplasty3. Describe the value of radiostereographic analysis in assessing implant stability.4. Appreciate the limitations in the available literature advocating 1 mode of fixation in total knee arthroplasty. Total knee arthroplasty performed worldwide uses either cemented, cementless, or hybrid (cementless femur with a cemented tibia) fixation of the components. No recent literature review concerning the outcomes of cemented vs noncemented components has been performed. Noncemented components offer the potential advantage of a biologic interface between the bone and implants, which could demonstrate the greatest advantage in long-term durable fixation in the follow-up of young patients undergoing arthroplasty. Several advances have been made in the backing of the tibial components that have not been available long enough to yield long-term comparative follow-up studies. Short-term radiostereographic analysis studies have yielded differing results. Although long-term, high-quality studies are still needed, material advances in biologic fixation surfaces, such as trabecular metal and hydroxyapatite, may offer promising results for young and active patients undergoing total knee arthroplasty when compared with traditional cemented options.
Collapse
Affiliation(s)
- Thomas E Brown
- Division of Adult Reconstruction, Department of Orthopaedics, University of Virginia, Charlottesville, Virginia 22903, USA.
| | | | | |
Collapse
|
39
|
|
40
|
Pijls BG, Nieuwenhuijse MJ, Schoones JW, Middeldorp S, Valstar ER, Nelissen RGHH. RSA prediction of high failure rate for the uncoated Interax TKA confirmed by meta-analysis. Acta Orthop 2012; 83:142-7. [PMID: 22530953 PMCID: PMC3339527 DOI: 10.3109/17453674.2012.672092] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
BACKGROUND AND PURPOSE In a previous radiostereometric (RSA) trial the uncoated, uncemented, Interax tibial components showed excessive migration within 2 years compared to HA-coated and cemented tibial components. It was predicted that this type of fixation would have a high failure rate. The purpose of this systematic review and meta-analysis was to investigate whether this RSA prediction was correct. MATERIALS AND METHODS We performed a systematic review and meta-analysis to determine the revision rate for aseptic loosening of the uncoated and cemented Interax tibial components. RESULTS 3 studies were included, involving 349 Interax total knee arthroplasties (TKAs) for the comparison of uncoated and cemented fixation. There were 30 revisions: 27 uncoated and 3 cemented components. There was a 3-times higher revision rate for the uncoated Interax components than that for cemented Interax components (OR = 3; 95% CI: 1.4-7.2). INTERPRETATION This meta-analysis confirms the prediction of a previous RSA trial. The uncoated Interax components showed the highest migration and turned out to have the highest revision rate for aseptic loosening. RSA appears to enable efficient detection of an inferior design as early as 2 years postoperatively in a small group of patients.
Collapse
Affiliation(s)
| | | | | | - Saskia Middeldorp
- Department of Clinical Epidemiology, Leiden University Medical Centre, Leiden,
| | | | | |
Collapse
|