Portet A, Besnard M, Ratsimbazafy C, Berhouet J, Samargandi R, Le Nail LR. The RM Press fit cup™: an investigation in 182 hips at ten-year follow-up. Orthop Traumatol Surg Res 2024:103988. [PMID: 39245266 DOI: 10.1016/j.otsr.2024.103988] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/05/2024] [Revised: 08/04/2024] [Accepted: 09/05/2024] [Indexed: 09/10/2024]
Abstract
INTRODUCTION For over 10 years, the RM Pressfit cup™ has been used in our department. This is a one-piece, elastic, cementless implant designed with standard polyethylene (PE), covered with a thin coating of titanium particles. To date, there is no French study evaluating this cup after more than 10 years. Therefore, we conducted a retrospective study in order to: (1) evaluate the survival of the implant with a minimum follow-up of 10 years, (2) evaluate the functional scores at the last follow-up, (3) measure the wear of the PE, (4) identify radiological loosening, (5) search for risk factors for cup removal, (6) identify complications that required management in the operating theatre. HYPOTHESIS The working hypothesis was that the survival of this implant was greater than 95% at 10 years' follow-up, in accordance with the criteria of the National Institute for Health and Care Excellence (NICE). MATERIALS AND METHODS This was a retrospective monocentric study, including adult patients who underwent total hip arthroplasty (THA) with an RM Pressfit cup™ (28 mm friction size) for coxarthrosis (primary or secondary) or femoral head osteonecrosis. Exclusion criteria were a follow-up period of less than 10 years, the placement of an RM Pressfit cup™ as a secondary intention for a THA (n = 5) or following a trochanteric fracture (n = 1). In total, 163 patients (182 hips) with a median age (Q1-Q3) of 63 (56-68) years, and a sex ratio (M/F) of 1.7 were included. Functional scores were evaluated using the Harris and Oxford scores. Radiographs were analyzed in the immediate postoperative period and at the last follow-up. RESULTS The median follow-up was 10.5 (10-11.5) years. Of the 182 included hips, 7 cups were removed, corresponding to a 10-year survival rate of 96.1% (95% CI [93.3; 96.9]). The median Harris and Oxford scores at 10.5 years were 95 (90-98) and 19 (17-23) points, respectively. The median PE wear rate was 0.058 (0.039-0.087) mm/year. Univariate analysis showed that male gender was associated with PE wear (OR = 3.6; 95% CI [1.3; 12.9] [p = 0.012]). Ten cups (6%) showed radiological instability with migration greater than 3 mm and/or variation in inclination greater than 8 °, and only 9 hips (6%) showed bone resorption. No preoperative or perioperative factors analyzed were associated with cup removal. Dislocation accounted for 71% (n = 5) of the causes of cup removal. Additionally, 6 hips experienced at least one dislocation episode requiring reduction by external maneuvers in the operating room, bringing the overall dislocation rate in the series to 6% (n = 11). Increased cup inclination was the only risk factor for prosthetic dislocation (OR = 1.2; 95% CI [1.09; 1.4] [p = 0.0003]). Overall complications requiring surgical intervention included 15 (8.3%) implanted cups (7 removed cups, 6 dislocation episodes requiring reduction by external maneuvers in the operating room, and 2 hips reoperated for washing and changing of mobile components due to early infection). CONCLUSION The RM Pressfit cup™ gives good long-term clinical and radiological results with an overall survival of 96.1% and a low complication rate over 10 years. Over the last 2 years the RM Vitamys™ cup has been introduced allowing the use of 32 mm femoral head diameter for size 48 cups, to reduce the risk of dislocation. LEVEL OF EVIDENCE IV; retrospective cohort.
Collapse
Affiliation(s)
- Adrien Portet
- Service de Chirurgie Orthopédique, Hôpital Trousseau, CHRU de Tours, Avenue de la République, Chambray-lès-Tours, Tours Cedex 9, 37044, France.
| | - Marion Besnard
- Centre Hospitalier Intercommunal Amboise-Château-Renault, Hôpital Robert-Debré, rue des Ursulines, BP 329, 37403 Amboise Cedex, France
| | - Carole Ratsimbazafy
- Hôpital Saint-Antoine, Pharmacie, GHU AP-HP Sorbonne Université 184 rue du Faubourg-Saint-Antoine, 75012 Paris, France
| | - Julien Berhouet
- Service de Chirurgie Orthopédique, Hôpital Trousseau, CHRU de Tours, Avenue de la République, Chambray-lès-Tours, Tours Cedex 9, 37044, France
| | - Ramy Samargandi
- Service de Chirurgie Orthopédique, Hôpital Trousseau, CHRU de Tours, Avenue de la République, Chambray-lès-Tours, Tours Cedex 9, 37044, France; Department of Orthopedic Surgery, Faculty of Medicine, University of Jeddah, Jeddah, Saudi Arabia
| | - Louis-Romée Le Nail
- Service de Chirurgie Orthopédique, Hôpital Trousseau, CHRU de Tours, Avenue de la République, Chambray-lès-Tours, Tours Cedex 9, 37044, France
| |
Collapse
|
2
|
White-Gibson A, Sheridan GA, Ghetti AC, Keogh P, Kenny P, Cashman JP. The utility of cemented femoral stems in modern THA: a 10-year comparative analysis of the Charnley and Exeter stems. Ir J Med Sci 2024; 193:251-255. [PMID: 37243843 PMCID: PMC10810030 DOI: 10.1007/s11845-023-03381-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2022] [Accepted: 04/19/2023] [Indexed: 05/29/2023]
Abstract
BACKGROUND Total hip replacement (THR) is one of the most common surgical procedures performed worldwide. The controversy surrounding the relative merits of a cemented composite beam or cemented taper-slip stem in total hip replacement continues. Our aims primarily were to assess the 10-year outcomes of cemented stems using Charnley and Exeter prostheses with regional registry data and secondarily to assess the main predictors of revision. METHODS We prospectively collected registry data for procedures performed between January 2005 and June 2008. Only cemented Charnley and Exeter stems were included. Patients were prospectively reviewed at 6 months, 2, 5 and 10 years. The primary outcome measure was a 10-year all-cause revision. Secondary outcomes included 're-revision', 'mortality' and functional 'Western Ontario and McMaster Universities Osteoarthritis Index' (WOMAC) scores. RESULTS We recorded a total of 1351 cases in the cohort, 395 Exeter and 956 Charnley stems. The overall all-cause revision rate at 10 years was 1.6%. The revision rate for Charnley stem was 1.4% and 2.3% revision rate for all Exeter stems with no significant difference noted between the two cohorts (p = 0.24). The overall time to revision was 38.3 months. WOMAC scores at 10 years were found to be insignificantly higher for Charnley stems (mean 23.8, σ = 20.11) compared to Exeter stems (mean 19.78, σ = 20.72) (p = 0.1). CONCLUSION There is no significant difference between cemented Charnley and Exeter stems; they both perform well above the international average. The decline in the use of cemented THA is not fully supported by this regional registry data.
Collapse
Affiliation(s)
| | | | | | - Peter Keogh
- The National Orthopaedic Hospital, Cappagh, Dublin, Ireland
| | - Paddy Kenny
- The National Orthopaedic Hospital, Cappagh, Dublin, Ireland
| | | |
Collapse
|
3
|
Afghanyar Y, Möller JH, Wunderlich F, Dargel J, Rehbein P, Gercek E, Drees P, Kutzner KP. An isoelastic monoblock cup versus a modular metal-back cup: a matched-pair analysis of clinical and radiological results using Einzel-Bild-Röntgen-Analyse software. Arch Orthop Trauma Surg 2024; 144:493-500. [PMID: 37740060 PMCID: PMC10774207 DOI: 10.1007/s00402-023-05058-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/16/2023] [Accepted: 09/01/2023] [Indexed: 09/24/2023]
Abstract
INTRODUCTION Bone preservation and long-term survival are the main challenges in cementless total hip arthroplasty (THA). A good bone stock is especially important for adequate anchorage of the cup in revision cases. However, the optimal acetabular cup design for preserving good bone stock is still unclear. We aimed to compare clinical outcome, radiological alterations, migration, and wear at mid-term for two different cup types. MATERIALS AND METHODS This retrospective matched-pair study was performed using the data for 98 THA cases treated with a monoblock cup composed of vitamin E-blended highly cross-linked polyethylene (VEPE; monoblock group) or a modular cup composed of a highly cross-linked polyethylene (HXLPE) without an antioxidant (modular group). Clinical results were evaluated using the Harris Hip Score (HHS). The obtained radiographs were analyzed for radiological alterations, migration, and wear using Einzel-Bild-Röntgen-Analyse (EBRA) software. RESULTS The mean follow-up duration was 73.2 ± 19.2 months (range: 32-108 months) and 60.5 ± 12.2 months (range: 20-84 months) in the monoblock and modular groups, respectively. HHS improved to 95.7 points in the monoblock group and 97.6 points in the modular group, without significant differences (p = 0.425). EBRA measurements were obtained in all cases. Acetabular bone alterations were not detected on radiological assessments. Mean cup migration was 1.67 ± 0.92 mm (range: 0.46-3.94 mm) and 1.24 ± 0.87 mm (range: 0.22-3.62 mm) in the monoblock and modular groups. The mean wear rate was 0.21 ± 0.18 mm (range: 0.00-0.70 mm) and 0.20 ± 0.13 mm (range: 0.00-0.50 mm) in the monoblock and modular groups. Both migration and wear pattern showed no significant differences (p = 0.741 and 0.243). None of the cases required revision surgery, yielding an implant survival rate of 100% in both groups. CONCLUSION The isoelastic press-fit monoblock VEPE cup and modular metal-back HXLPE cup showed equivalent mid-term wear and cup migration. Long-term studies are required to determine the effects of modularity, isoelasticity, and polyethylene stabilization with vitamin E on cup loosening and survival rates.
Collapse
Affiliation(s)
- Yama Afghanyar
- Department of Orthopaedics and Traumatology, University Medical Centre of the Johannes Gutenberg-University of Mainz, Mainz, Germany.
- Department of Orthopaedics and Traumatology, St. Josefs Hospital Wiesbaden, Wiesbaden, Germany.
| | - Jens Hendrik Möller
- Department of Orthopaedics and Traumatology, St. Josefs Hospital Wiesbaden, Wiesbaden, Germany
| | - Felix Wunderlich
- Department of Orthopaedics and Traumatology, University Medical Centre of the Johannes Gutenberg-University of Mainz, Mainz, Germany
| | - Jens Dargel
- Department of Orthopaedics and Traumatology, St. Josefs Hospital Wiesbaden, Wiesbaden, Germany
| | - Philipp Rehbein
- Department of Orthopaedics and Traumatology, St. Josefs Hospital Wiesbaden, Wiesbaden, Germany
| | - Erol Gercek
- Department of Orthopaedics and Traumatology, University Medical Centre of the Johannes Gutenberg-University of Mainz, Mainz, Germany
| | - Philipp Drees
- Department of Orthopaedics and Traumatology, University Medical Centre of the Johannes Gutenberg-University of Mainz, Mainz, Germany
| | - Karl Philipp Kutzner
- Department of Orthopaedics and Traumatology, University Medical Centre of the Johannes Gutenberg-University of Mainz, Mainz, Germany
- Department of Orthopaedics and Traumatology, St. Josefs Hospital Wiesbaden, Wiesbaden, Germany
| |
Collapse
|
4
|
Synnott PA, Sivaloganathan S, Kiss MO, Binette B, Morcos MW, Vendittoli PA. Monobloc press-fit cups with large-diameter bearings are safe in revision total hip arthroplasty. Orthop Rev (Pavia) 2022; 14:38926. [PMID: 36349354 PMCID: PMC9635988 DOI: 10.52965/001c.38926] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
BACKGROUND Instability is a major cause of failure of revision total hip arthroplasty (THA) which can be avoided with the use of monobloc press-fit cups with large diameter heads (LDH). OBJECTIVE This consecutive case series analyses whether LDH monobloc components are a safe and clinically beneficial option for revision THA. METHODS This consecutive case series includes 47 revision THA with LDH monobloc acetabular cup. Acetabular bone defects were Paprosky type I (42), type IIA (2) and type IIC (3). The Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Forgotten Joint Score (FJS) and the Patient's Joint Perception (PJP) scores were analysed and a radiographic evaluation for signs of implant dysfunction was performed. RESULTS After a mean follow-up of 4.5 years, there were 5 (10.6%) acetabular cup re-revisions: 2 loss of primary fixation and 3 instabilities. Implant survivorship at 4-years was 89.4% (95% CI: 89.3 to 89.5). Recurrent hip dislocation was reported in 1 patient (2.1%) and remains under conservative treatment. The mean WOMAC and FJS were 19.5 (16.8; 0.0 to 58.3) and 57.3 (28.9; 6.3 to 100.0), respectively. Regarding the PJP, 3 (8.8%) patients perceived their hip as natural, 8 (23.5%) as an artificial joint with no restriction, 14 (41.2%) with minor restriction and 9 (26.5%) with major restriction. CONCLUSION In cases of revision THA with limited bone loss, press-fit primary fixation with LDH monobloc acetabular components are valuable options that offer excellent mid-term out-comes with low re-revision and joint instability rates.
Collapse
Affiliation(s)
| | - Sivan Sivaloganathan
- University of Montreal, Hôpital Maisonneuve-Rosemont; Surgery Department, Montreal University
| | - Marc-Olivier Kiss
- University of Montreal, Hôpital Maisonneuve-Rosemont; Surgery Department, Montreal University; Clinique Orthopédique Duval, Laval, Canada
| | - Benoit Binette
- University of Montreal, Hôpital Maisonneuve-Rosemont; Surgery Department, Montreal University
| | - Mina W. Morcos
- University of Montreal, Hôpital Maisonneuve-Rosemont; Surgery Department, Montreal University
| | - Pascal-André Vendittoli
- University of Montreal, Hôpital Maisonneuve-Rosemont; Surgery Department, Montreal University; Clinique Orthopédique Duval, Laval, Canada; Personalized Arthroplasty Society, Georgia, USA
| |
Collapse
|
5
|
Kenanidis E, Kakoulidis P, Leonidou A, Anagnostis P, Potoupnis M, Tsiridis E. Survival of monoblock RM vitamys compared with modular PINNACLE cups: mid-term outcomes of 200 hips performed by a single surgeon. Hip Int 2021; 31:465-471. [PMID: 31694404 DOI: 10.1177/1120700019885619] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
INTRODUCTION Monoblock cups have theoretical advantages over modular cups; however, their superiority in terms of survival has not been confirmed in comparative studies. METHODS We compared the mid-term survivorship of 107 RM Pressfit vitamys monoblock cups (Mathys Ltd., Bettlach, Switzerland) with 93 modular pressfit Pinnacle cups (DePuy Synthes, Warsaw, IN, USA). All cases were registered in the Arthroplasty Registry Thessaloniki and performed by a senior surgeon through the same approach between 2013 and 2014. The groups were comparable in sex distribution, preoperative diagnosis, follow-up, cup diameter, head diameter, type and use of screws, HOOS and HSS preop scores; the recipients of RM cup were significantly younger. RESULTS 3 sockets were revised. The 6-year survival for any reason was 99.1% for the RM and 97.8 % for the PINNACLE group. There was no difference in survival for aseptic loosening and any reason between groups (log-rank test p = 0.921 and p = 0.483, respectively). The age (95% CI, 0.79-1.1), sex (95% CI, 0.2-45.0), cup diameter (95% CI, 0.18-1.1), head diameter (95% CI, 0.004-6.2), preoperative diagnosis and use of screws (95% CI, 0.02-4.3), did not influence hazard ratio for revision between groups. HHS and HOOS were comparable at the last follow-up. CONCLUSIONS Our study demonstrated that both cup designs had similar revision rates at mid-term follow-up, regardless the fact that the RM vitamys was used in a cohort of younger patients; which according to the literature would have led to earlier failures. Further long-term data are needed to evaluate the superiority of RM vitamys in the clinical setting, especially in the young.
Collapse
Affiliation(s)
- Eustathios Kenanidis
- Academic Orthopaedic Department, Aristotle University Medical School, General Hospital Papageorgiou, Greece.,Centre of Orthopaedic and Regenerative Medicine (CORE), Centre for Interdisciplinary Research and Innovation (CIRI)-Aristotle University of Thessaloniki (AUTH), Thessaloniki, Greece
| | - Panagiotis Kakoulidis
- Academic Orthopaedic Department, Aristotle University Medical School, General Hospital Papageorgiou, Greece.,Centre of Orthopaedic and Regenerative Medicine (CORE), Centre for Interdisciplinary Research and Innovation (CIRI)-Aristotle University of Thessaloniki (AUTH), Thessaloniki, Greece
| | - Andreas Leonidou
- Centre of Orthopaedic and Regenerative Medicine (CORE), Centre for Interdisciplinary Research and Innovation (CIRI)-Aristotle University of Thessaloniki (AUTH), Thessaloniki, Greece.,Royal Berkshire NHS Foundation Trust, Reading, UK
| | - Panagiotis Anagnostis
- Centre of Orthopaedic and Regenerative Medicine (CORE), Centre for Interdisciplinary Research and Innovation (CIRI)-Aristotle University of Thessaloniki (AUTH), Thessaloniki, Greece
| | - Michael Potoupnis
- Academic Orthopaedic Department, Aristotle University Medical School, General Hospital Papageorgiou, Greece.,Centre of Orthopaedic and Regenerative Medicine (CORE), Centre for Interdisciplinary Research and Innovation (CIRI)-Aristotle University of Thessaloniki (AUTH), Thessaloniki, Greece
| | - Eleftherios Tsiridis
- Academic Orthopaedic Department, Aristotle University Medical School, General Hospital Papageorgiou, Greece.,Centre of Orthopaedic and Regenerative Medicine (CORE), Centre for Interdisciplinary Research and Innovation (CIRI)-Aristotle University of Thessaloniki (AUTH), Thessaloniki, Greece
| |
Collapse
|
6
|
Vitamin E-blended versus conventional polyethylene liners in prostheses : Prospective, randomized trial with 3-year follow-up. DER ORTHOPADE 2021; 49:1077-1085. [PMID: 31696260 DOI: 10.1007/s00132-019-03830-6] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
BACKGROUND Despite continuous technical improvements, polyethylene wear debris induced periprosthetic osteolysis remains the main cause for failure of hip arthroplasty. Progressive oxidation of polyethylene was identified as another risk factor for material failure. To overcome this problem, antioxidants such as vitamin E (alpha-tocopherol) were supplemented by diffusion into the latest generation of polyethylene liners. OBJECTIVE The purpose of the present study was to investigate the clinical outcome of patients treated with vitamin E blended highly cross-linked ultra-high molecular weight polyethylene liners (UHMWPE-XE) in comparison with conventional UHMWPE‑X liners by evaluating patient-reported outcome measures (PROM's) at 3‑year follow-up. METHODS A total of 143 patients were recruited into this prospective, randomized trial in our academic center. Three years after implantation, 101 patients were examined in the outpatient clinic for follow-up. Of these, 51 (50.5%) received UHMWPE-XE and 50 (49.5%) UHMWPE‑X liners. Clinical outcome was evaluated using Harris-Hip-Score (HHS) UCLA-Score and Hip Disability and Osteoarthritis Outcome Score (HOOS). RESULTS There was a significant improvement in all PROM's at one- and three-year follow-up compared to the status before implantation. PROM's did not differ significantly between the first and third year follow-up. Both liner groups showed an equal clinical outcome. CONCLUSION The present study demonstrates that the supplementation of vitamin E to polyethylene liners is reliable and safe without showing higher complication rates compared with conventional polyethylene liners. The shortterm clinical outcome of vitamin E-blended (UHMWPE‑XE) is equivalent to those of conventional highly cross-linked polyethylene liners.
Collapse
|
7
|
Castagnini F, Bordini B, Stea S, Calderoni PP, Masetti C, Busanelli L. Highly porous titanium cup in cementless total hip arthroplasty: registry results at eight years. INTERNATIONAL ORTHOPAEDICS 2019; 43:1815-1821. [PMID: 30141142 DOI: 10.1007/s00264-018-4102-9] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/12/2018] [Accepted: 08/08/2018] [Indexed: 02/07/2023]
Abstract
PURPOSE Highly porous cups were developed to improve osseointegration and reduce the rate of aseptic loosening. Highly porous titanium cups could mix the reliability of titanium metal with an enhanced porosity, improving the bony ingrowth. The aim of this report was to assess the survival rates and reasons for revision of a highly porous titanium cup, Fixa Ti-Por (Adler Ortho, Milan, Italy), fabricated using an additive manufacturing. METHODS The Registry of Prosthetic Orthopedic Implants (RIPO), the Emilia-Romagna region arthroplasty registry, was enquired about cementless cups, implanted since July 2007. Ti-Por cups were compared to all the other cementless sockets, acting as a control group. The survival rates and reasons for revision were evaluated and compared. Comparisons with the same articular couplings were also provided. RESULTS When all the articular couplings were included, Ti-Por performed better, achieving a statistically higher survival rate than the control group (98.7% vs 97.9%) and a statistically lower incidence of cup aseptic loosening. In case of ceramic on polyethylene couplings, Ti-Por achieved similar survival rate: cup aseptic loosening in Ti-Por group was 0.2%, whereas the control group rated 0.4%. In ceramic-on-ceramic implants, the survival rate was similar in the two groups, Ti-Por achieving a cup aseptic loosening rate of 0.1% (vs 0.14% in the control group). CONCLUSION Highly porous titanium cups showed trustworthy results at eight years, reducing the rate of aseptic loosening. Longer follow-ups, ion analyses, and pre-clinical in vivo studies would be helpful to better define the reliability of these devices and their advantages.
Collapse
Affiliation(s)
- Francesco Castagnini
- Ortopedia-Traumatologia e Chirurgia protesica e dei reimpianti d'anca e di ginocchio, IRCCS Istituto Ortopedico Rizzoli, Via Pupilli 1, 40136, Bologna, Italy.
| | - Barbara Bordini
- Laboratorio di Tecnologia Medica, IRCCS Istituto Ortopedico Rizzoli, Via di Barbiano 1/10, 40136, Bologna, Italy
| | - Susanna Stea
- Laboratorio di Tecnologia Medica, IRCCS Istituto Ortopedico Rizzoli, Via di Barbiano 1/10, 40136, Bologna, Italy
| | - Pierina Paola Calderoni
- Ortopedia-Traumatologia e Chirurgia protesica e dei reimpianti d'anca e di ginocchio, IRCCS Istituto Ortopedico Rizzoli, Via Pupilli 1, 40136, Bologna, Italy
| | - Claudio Masetti
- Ortopedia-Traumatologia e Chirurgia protesica e dei reimpianti d'anca e di ginocchio, IRCCS Istituto Ortopedico Rizzoli, Via Pupilli 1, 40136, Bologna, Italy
| | - Luca Busanelli
- Ortopedia-Traumatologia e Chirurgia protesica e dei reimpianti d'anca e di ginocchio, IRCCS Istituto Ortopedico Rizzoli, Via Pupilli 1, 40136, Bologna, Italy
| |
Collapse
|
8
|
The effect of cement on hip stem fixation: a biomechanical study. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE 2017; 40:349-357. [PMID: 28321636 DOI: 10.1007/s13246-017-0539-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/22/2016] [Accepted: 03/06/2017] [Indexed: 10/19/2022]
Abstract
This study presents the numerical analysis of stem fixation in hip surgery using with/without cement methods since the use of cement is still controversial based on the clinical studies in the literature. Many different factors such as stress shielding, aseptic loosening, material properties of the stem, surgeon experiences etc. play an important role in the failure of the stem fixations. The stem fixation methods, cemented and uncemented, were evaluated in terms of mechanical failure aspects using computerized finite element method. For the modeling processes, three dimensional (3D) femur model was generated from computerized tomography (CT) images taken from a patient using the MIMICS Software. The design of the stem was also generated as 3D CAD model using the design parameters taken from the manufacturer catalogue. These 3D CAD models were generated and combined with/without cement considering the surgical procedure using SolidWorks program and then imported into ANSYS Workbench Software. Two different material properties, CoCrMo and Ti6Al4V, for the stem model and Poly Methyl Methacrylate (PMMA) for the cement were assigned. The material properties of the femur were described according to a density calculated from the CT images. Body weight and muscle forces were applied on the femur and the distal femur was fixed for the boundary conditions. The calculations of the stress distributions of the models including cement and relative movements of the contacts examined to evaluate the effects of the cement and different stem material usage on the failure of stem fixation. According to the results, the use of cement for the stem fixation reduces the stress shielding but increases the aseptic loosening depending on the cement crack formations. Additionally, using the stiffer material for the stem reduces the cement stress but increases the stress shielding. Based on the results obtained in the study, even when taking the disadvantages into account, the cement usage is more suitable for the hip fixations.
Collapse
|
9
|
Towle KM, Monnot AD. An Assessment of Gender-Specific Risk of Implant Revision After Primary Total Hip Arthroplasty: A Systematic Review and Meta-analysis. J Arthroplasty 2016; 31:2941-2948. [PMID: 27659397 DOI: 10.1016/j.arth.2016.07.047] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/10/2016] [Revised: 07/15/2016] [Accepted: 07/21/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Total hip arthroplasty (THA) has been a successful reconstructive procedure to mitigate pain associated with diseases of the hip joint. However, some THA procedures require revision due to mechanical or biological failure. The purpose of this study was to synthesize and examine the evidence on the relative risk of revision in men and women after primary THA procedures. METHODS We conducted a systematic literature review of cohort studies reporting THA revision risk estimate by gender. Study quality scoring and a random effects meta-analysis were performed to estimate the meta-relative risk (meta-RR) and corresponding 95% confidence interval (95% CI) of revision, comparing men to women. RESULTS Males had a statistically significant increased risk of revision after primary THA (meta-RR = 1.33 [95% CI: 1.13-1.57]), when compared to females. When stratified by cause of revision, males had a statistically significant increased risk of revision due to any cause (meta-RR = 1.16 [95% CI: 1.01-1.33]), aseptic loosening (meta-RR = 1.54 [95% CI: 1.05-2.25]), and infection (meta-RR = 1.55 [95% CI: 1.11-2.15]). For primary THA operations performed during the 2000s, males in Europe had a statistically significant increased risk of revision (meta-RR 1.42 [95% CI: 1.25-1.61]) while males in the United States had a statistically significant decreased risk of revision (meta-RR 0.80 [95% CI: 0.72-0.89]). CONCLUSION These results provide evidence for an increased risk of revision after THA among males, which may be impacted by geographic location and time period of operation. Findings suggest that a better understanding of the underlying drivers of gender-specific risks would help reduce postsurgery complications.
Collapse
|
10
|
Nich C. CORR Insights(®): Backside Wear Is Not Dependent on the Acetabular Socket Design in Crosslinked Polyethylene Liners. Clin Orthop Relat Res 2016; 474:383-5. [PMID: 26260395 PMCID: PMC4709286 DOI: 10.1007/s11999-015-4502-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/29/2015] [Accepted: 08/04/2015] [Indexed: 01/31/2023]
Affiliation(s)
- Christophe Nich
- Department of Orthopaedic Surgery, Raymond Poincaré University Hospital, 104 Raymond Poincaré Blvd, Garches, 92380 France
| |
Collapse
|
11
|
Clarke A, Pulikottil-Jacob R, Grove A, Freeman K, Mistry H, Tsertsvadze A, Connock M, Court R, Kandala NB, Costa M, Suri G, Metcalfe D, Crowther M, Morrow S, Johnson S, Sutcliffe P. Total hip replacement and surface replacement for the treatment of pain and disability resulting from end-stage arthritis of the hip (review of technology appraisal guidance 2 and 44): systematic review and economic evaluation. Health Technol Assess 2015; 19:1-668, vii-viii. [PMID: 25634033 DOI: 10.3310/hta19100] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
BACKGROUND Total hip replacement (THR) involves the replacement of a damaged hip joint with an artificial hip prosthesis. Resurfacing arthroplasty (RS) involves replacement of the joint surface of the femoral head with a metal surface covering. OBJECTIVES To undertake clinical effectiveness and cost-effectiveness analysis of different types of THR and RS for the treatment of pain and disability in people with end-stage arthritis of the hip, in particular to compare the clinical effectiveness and cost-effectiveness of (1) different types of primary THR and RS for people in whom both procedures are suitable and (2) different types of primary THR for people who are not suitable for hip RS. DATA SOURCES Electronic databases including MEDLINE, EMBASE, The Cochrane Library, Current Controlled Trials and UK Clinical Research Network (UKCRN) Portfolio Database were searched in December 2012, with searches limited to publications from 2008 and sample sizes of ≥ 100 participants. Reference lists and websites of manufacturers and professional organisations were also screened. REVIEW METHODS Systematic reviews of the literature were undertaken to appraise the clinical effectiveness and cost-effectiveness of different types of THR and RS for people with end-stage arthritis of the hip. Included randomised controlled trials (RCTs) and systematic reviews were data extracted and risk of bias and methodological quality were independently assessed by two reviewers using the Cochrane Collaboration risk of bias tool and the Assessment of Multiple Systematic Reviews (AMSTAR) tool. A Markov multistate model was developed for the economic evaluation of the technologies. Sensitivity analyses stratified by sex and controlled for age were carried out to assess the robustness of the results. RESULTS A total of 2469 records were screened of which 37 were included, representing 16 RCTs and eight systematic reviews. The mean post-THR Harris Hip Score measured at different follow-up times (from 6 months to 10 years) did not differ between THR groups, including between cross-linked polyethylene and traditional polyethylene cup liners (pooled mean difference 2.29, 95% confidence interval -0.88 to 5.45). Five systematic reviews reported evidence on different types of THR (cemented vs. cementless cup fixation and implant articulation materials) but these reviews were inconclusive. Eleven cost-effectiveness studies were included; four provided relevant cost and utility data for the model. Thirty registry studies were included, with no studies reporting better implant survival for RS than for all types of THR. For all analyses, mean costs for RS were higher than those for THR and mean quality-adjusted life-years (QALYs) were lower. The incremental cost-effectiveness ratio for RS was dominated by THR, that is, THR was cheaper and more effective than RS (for a lifetime horizon in the base-case analysis, the incremental cost of RS was £11,284 and the incremental QALYs were -0.0879). For all age and sex groups RS remained clearly dominated by THR. Cost-effectiveness acceptability curves showed that, for all patients, THR was almost 100% cost-effective at any willingness-to-pay level. There were age and sex differences in the populations with different types of THR and variations in revision rates (from 1.6% to 3.5% at 9 years). For the base-case analysis, for all age and sex groups and a lifetime horizon, mean costs for category E (cemented components with a polyethylene-on-ceramic articulation) were slightly lower and mean QALYs for category E were slightly higher than those for all other THR categories in both deterministic and probabilistic analyses. Hence, category E dominated the other four categories. Sensitivity analysis using an age- and sex-adjusted log-normal model demonstrated that, over a lifetime horizon and at a willingness-to-pay threshold of £20,000 per QALY, categories A and E were equally likely (50%) to be cost-effective. LIMITATIONS A large proportion of the included studies were inconclusive because of poor reporting, missing data, inconsistent results and/or great uncertainty in the treatment effect estimates. This warrants cautious interpretation of the findings. The evidence on complications was scarce, which may be because of the absence or rarity of these events or because of under-reporting. The poor reporting meant that it was not possible to explore contextual factors that might have influenced study results and also reduced the applicability of the findings to routine clinical practice in the UK. The scope of the review was limited to evidence published in English in 2008 or later, which could be interpreted as a weakness; however, systematic reviews would provide summary evidence for studies published before 2008. CONCLUSIONS Compared with THR, revision rates for RS were higher, mean costs for RS were higher and mean QALYs gained were lower; RS was dominated by THR. Similar results were obtained in the deterministic and probabilistic analyses and for all age and sex groups THR was almost 100% cost-effective at any willingness-to-pay level. Revision rates for all types of THR were low. Category A THR (cemented components with a polyethylene-on-metal articulation) was more cost-effective for older age groups. However, across all age-sex groups combined, the mean cost for category E THR (cemented components with a polyethylene-on-ceramic articulation) was slightly lower and the mean QALYs gained were slightly higher. Category E therefore dominated the other four categories. Certain types of THR appeared to confer some benefit, including larger femoral head sizes, use of a cemented cup, use of a cross-linked polyethylene cup liner and a ceramic-on-ceramic as opposed to a metal-on-polyethylene articulation. Further RCTs with long-term follow-up are needed. STUDY REGISTRATION This study is registered as PROSPERO CRD42013003924. FUNDING The National Institute for Health Research Health Technology Assessment programme.
Collapse
Affiliation(s)
- Aileen Clarke
- Warwick Evidence, Warwick Medical School, University of Warwick, Coventry, UK
| | | | - Amy Grove
- Warwick Evidence, Warwick Medical School, University of Warwick, Coventry, UK
| | - Karoline Freeman
- Warwick Evidence, Warwick Medical School, University of Warwick, Coventry, UK
| | - Hema Mistry
- Warwick Evidence, Warwick Medical School, University of Warwick, Coventry, UK
| | | | - Martin Connock
- Warwick Evidence, Warwick Medical School, University of Warwick, Coventry, UK
| | - Rachel Court
- Warwick Evidence, Warwick Medical School, University of Warwick, Coventry, UK
| | | | - Matthew Costa
- Warwick Evidence, Warwick Medical School, University of Warwick, Coventry, UK
| | - Gaurav Suri
- Warwick Evidence, Warwick Medical School, University of Warwick, Coventry, UK
| | - David Metcalfe
- Warwick Orthopaedics, University Hospitals Coventry and Warwickshire, Coventry, UK
| | - Michael Crowther
- Department of Health Sciences, University of Leicester, Leicester, UK
| | - Sarah Morrow
- Oxford Medical School, University of Oxford, Oxford, UK
| | - Samantha Johnson
- Warwick Evidence, Warwick Medical School, University of Warwick, Coventry, UK
| | - Paul Sutcliffe
- Warwick Evidence, Warwick Medical School, University of Warwick, Coventry, UK
| |
Collapse
|
12
|
Mihalko WM, Wimmer MA, Pacione CA, Laurent MP, Murphy RF, Rider C. How have alternative bearings and modularity affected revision rates in total hip arthroplasty? Clin Orthop Relat Res 2014; 472:3747-58. [PMID: 25070918 PMCID: PMC4397767 DOI: 10.1007/s11999-014-3816-2] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Total hip arthroplasty (THA) continues to be one of the most successful surgical procedures in the medical field. However, over the last two decades, the use of modularity and alternative bearings in THA has become routine. Given the known problems associated with hard-on-hard bearing couples, including taper failures with more modular stem designs, local and systemic effects from metal-on-metal bearings, and fractures with ceramic-on-ceramic bearings, it is not known whether in aggregate the survivorship of these implants is better or worse than the metal-on-polyethylene bearings that they sought to replace. QUESTIONS/PURPOSES Have alternative bearings (metal-on-metal and ceramic-on-ceramic) and implant modularity decreased revision rates of primary THAs? METHODS In this systematic review of MEDLINE and EMBASE, we used several Boolean search strings for each topic and surveyed national registry data from English-speaking countries. Clinical research (Level IV or higher) with ≥ 5 years of followup was included; retrieval studies and case reports were excluded. We included registry data at ≥ 7 years followup. A total of 32 studies (and five registry reports) on metal-on-metal, 19 studies (and five registry reports) on ceramic-on-ceramic, and 20 studies (and one registry report) on modular stem designs met inclusion criteria and were evaluated in detail. Insufficient data were available on metal-on-ceramic and ceramic-on-metal implants, and monoblock acetabular designs were evaluated in another recent systematic review so these were not evaluated here. RESULTS There was no evidence in the literature that alternative bearings (either metal-on-metal or ceramic-on-ceramic) in THA have decreased revision rates. Registry data, however, showed that large head metal-on-metal implants have lower 7- to 10-year survivorship than do standard bearings. In THA, modular exchangeable femoral neck implants had a lower 10-year survival rate in both literature reviews and in registry data compared with combined registry primary THA implant survivorship. CONCLUSIONS Despite improvements in implant technology, there is no evidence that alternative bearings or modularity have resulted in decreased THA revision rates after 5 years. In fact, both large head metal-on-metal THA and added modularity may well lower survivorship and should only be used in select cases in which the mission cannot be achieved without it. Based on this experience, followup and/or postmarket surveillance studies should have a duration of at least 5 years before introducing new alternative bearings or modularity on a widespread scale.
Collapse
Affiliation(s)
- William M Mihalko
- Campbell Clinic Department of Orthopaedic Surgery and Biomedical Engineering, University of Tennessee, 956 Court Avenue, Suite E226, Memphis, TN, 38163, USA,
| | | | | | | | | | | |
Collapse
|
13
|
Nieuwenhuijse MJ, Nelissen RGHH, Schoones JW, Sedrakyan A. Appraisal of evidence base for introduction of new implants in hip and knee replacement: a systematic review of five widely used device technologies. BMJ 2014; 349:g5133. [PMID: 25208953 PMCID: PMC4159610 DOI: 10.1136/bmj.g5133] [Citation(s) in RCA: 56] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
OBJECTIVE To determine the evidence of effectiveness and safety for introduction of five recent and ostensibly high value implantable devices in major joint replacement to illustrate the need for change and inform guidance on evidence based introduction of new implants into healthcare. DESIGN Systematic review of clinical trials, comparative observational studies, and registries for comparative effectiveness and safety of five implantable device innovations. DATA SOURCES PubMed (Medline), Embase, Web of Science, Cochrane, CINAHL, reference lists of articles, annual reports of major registries, summaries of safety and effectiveness for pre-market application and mandated post-market studies at the US Food and Drug Administration. STUDY SELECTION The five selected innovations comprised three in total hip replacement (ceramic-on-ceramic bearings, modular femoral necks, and uncemented monoblock cups) and two in total knee replacement (high flexion knee replacement and gender specific knee replacement). All clinical studies of primary total hip or knee replacement for symptomatic osteoarthritis in adults that compared at least one of the clinical outcomes of interest (patient centred outcomes or complications, or both) in the new implant group and control implant group were considered. Data searching, abstraction, and analysis were independently performed and confirmed by at least two authors. Quantitative data syntheses were performed when feasible. RESULTS After assessment of 10,557 search hits, 118 studies (94 unique study cohorts) met the inclusion criteria and reported data related to 15,384 implants in 13,164 patients. Comparative evidence per device innovation varied from four low to moderate quality retrospective studies (modular femoral necks) to 56 studies of varying quality including seven high quality (randomised) studies (high flexion knee replacement). None of the five device innovations was found to improve functional or patient reported outcomes. National registries reported two to 12 year follow-up for revision occurrence related to more than 200,000 of these implants. Reported comparative data with well established alternative devices (over 1,200,000 implants) did not show improved device survival. Moreover, we found higher revision occurrence associated with modular femoral necks (hazard ratio 1.9) and ceramic-on-ceramic bearings (hazard ratio 1.0-1.6) in hip replacement and with high flexion knee implants (hazard ratio 1.0-1.8). CONCLUSION We did not find convincing high quality evidence supporting the use of five substantial, well known, and already implemented device innovations in orthopaedics. Moreover, existing devices may be safer to use in total hip or knee replacement. Improved regulation and professional society oversight are necessary to prevent patients from being further exposed to these and future innovations introduced without proper evidence of improved clinical efficacy and safety.
Collapse
Affiliation(s)
- Marc J Nieuwenhuijse
- Patient Centered Comparative Effectiveness Program and US Food and Drug Administration Medical Device Epidemiology Science and Infrastructure Center, Department of Public Health, Weill Cornell Medical College, New York, NY 10065, USA Department of Orthopaedics, Leiden University Medical Center, 2300 RC Leiden, Netherlands Office of Surveillance and Biometrics, Center for Devices and Radiological Health, FDA, Silver Spring, MD 20993, USA
| | - R G H H Nelissen
- Department of Orthopaedics, Leiden University Medical Center, 2300 RC Leiden, Netherlands
| | - J W Schoones
- Walaeus Library, Leiden University Medical Center, 2300 RC Leiden, Netherlands
| | - A Sedrakyan
- Patient Centered Comparative Effectiveness Program and US Food and Drug Administration Medical Device Epidemiology Science and Infrastructure Center, Department of Public Health, Weill Cornell Medical College, New York, NY 10065, USA Office of Surveillance and Biometrics, Center for Devices and Radiological Health, FDA, Silver Spring, MD 20993, USA
| |
Collapse
|
14
|
Higher revision and complication rates following total hip arthroplasty in patients with inflammatory bowel disease. J Arthroplasty 2014; 29:596-600. [PMID: 24231436 DOI: 10.1016/j.arth.2013.07.011] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/27/2013] [Revised: 05/23/2013] [Accepted: 07/08/2013] [Indexed: 02/01/2023] Open
Abstract
The purpose of this study was to compare the clinical outcomes of total hip arthroplasty in patients with and without inflammatory bowel disease (IBD). Between 2001 and 2010, all total hip arthroplasties performed at a single institution were reviewed to identify patients who had IBD. There were 23 total hip arthroplasties in the study group, which were matched in a 1:3 ratio to 69 additional hips. At a mean follow-up of 49 months (range, 24-96 months), patients with IBD had an overall significantly lower survivorship of 87% (n = 3 revisions), compared to 98.5% (n = 1 revision) in the matched group who had a mean follow-up of 47 months (range, 24-94 months). In addition, there were significantly higher major complications in the study group (5 patients) compared to the matched group (2 patients). These results indicate that patients with IBD had an overall higher revision and complication rate.
Collapse
|
15
|
Halma JJ, Vogely HC, Dhert WJ, Van Gaalen SM, de Gast A. Do monoblock cups improve survivorship, decrease wear, or reduce osteolysis in uncemented total hip arthroplasty? Clin Orthop Relat Res 2013; 471:3572-80. [PMID: 23913339 PMCID: PMC3792292 DOI: 10.1007/s11999-013-3144-y] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/01/2013] [Accepted: 06/25/2013] [Indexed: 01/31/2023]
Abstract
BACKGROUND Monoblock acetabular components used in uncemented total hip arthroplasty (THA) have certain mechanical characteristics that potentially reduce acetabular osteolysis and polyethylene wear. However, the degree to which they achieve this goal is not well documented. QUESTIONS/PURPOSES The purpose of this study was to use a systematic review of controlled trials to test the hypothesis that monoblock cups have superior (1) polyethylene wear rate; (2) frequency of cup migration; (3) frequency of acetabular osteolysis; and (4) frequency of aseptic loosening compared with modular components used in uncemented THA. METHODS A systematic search was conducted in the Medline, Embase, and Cochrane electronic databases to assemble all controlled trials comparing monoblock with modular uncemented acetabular components in primary THA. Included studies were considered "best evidence" if the quality score was either ≥ 50% on the Cochrane Back Review Group checklist or ≥ 75% the Newcastle-Ottawa quality assessment scale. A total of seven publications met our inclusion criteria. RESULTS Best evidence analysis showed no difference in polyethylene wear rate, the frequency of cup migration, and aseptic loosening between monoblock and modular acetabular components. No convincing evidence was found for the claim that lower frequencies of acetabular osteolysis are observed with the use of monoblock cups compared with modular uncemented cups. CONCLUSIONS The purported benefits of monoblock cups were not substantiated by this systematic review of controlled studies in that polyethylene wear rates and frequencies of cup failure and acetabular osteolysis were similar to those observed with modular implants. Other factors should therefore drive implant selection in cementless THA.
Collapse
Affiliation(s)
- Jelle J Halma
- Clinical Orthopedic Research Center-midden Nederland (CORC-mN), Department of Orthopaedics, Diakonessenhuis Hospital, PO Box 80250, 3508 TG, Utrecht, The Netherlands,
| | | | | | | | | |
Collapse
|
16
|
Abdulkarim A, Ellanti P, Motterlini N, Fahey T, O'Byrne JM. Cemented versus uncemented fixation in total hip replacement: a systematic review and meta-analysis of randomized controlled trials. Orthop Rev (Pavia) 2013; 5:e8. [PMID: 23705066 PMCID: PMC3662257 DOI: 10.4081/or.2013.e8] [Citation(s) in RCA: 81] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/10/2012] [Revised: 11/03/2012] [Accepted: 12/13/2012] [Indexed: 12/13/2022] Open
Abstract
The optimal method of fixation for primary total hip replacements (THR), particularly fixation with or without the use of cement is still controversial. In a systematic review and metaanalysis of all randomized controlled trials comparing cemented versus uncemented THRS available in the published literature, we found that there is no significant difference between cemented and uncemented THRs in terms of implant survival as measured by the revision rate. Better short-term clinical outcome, particularly an improved pain score can be obtained with cemented fixation. However, the results are unclear for the long-term clinical and functional outcome between the two groups. No difference was evident in the mortality and the post operative complication rate. On the other hand, the radiographic findings were variable and do not seem to correlate with clinical findings as differences in the surgical technique and prosthesis design might be associated with the incidence of osteolysis. We concluded in our review that cemented THR is similar if not superior to uncemented THR, and provides better short term clinical outcomes. Further research, improved methodology and longer follow up are necessary to better define specific subgroups of patients in whom the relative benefits of cemented and uncemented implant fixation can be clearly demonstrated.
Collapse
Affiliation(s)
- Ali Abdulkarim
- Department of Orthopaedics, Cappagh National Orthopaedic Hospital, Finglas, Dublin; Royal College of Surgeons, Dublin, Ireland
| | | | | | | | | |
Collapse
|