1
|
Yoda H, Abe K, Takeo H, Takamura-Enya T, Koike-Takeshita A. Application of image-recognition techniques to automated micronucleus detection in the in vitro micronucleus assay. Genes Environ 2024; 46:11. [PMID: 38659010 PMCID: PMC11040892 DOI: 10.1186/s41021-024-00305-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2023] [Accepted: 04/11/2024] [Indexed: 04/26/2024] Open
Abstract
BACKGROUND An in vitro micronucleus assay is a standard genotoxicity test. Although the technique and interpretation of the results are simple, manual counting of the total and micronucleus-containing cells in a microscopic field is tedious. To address this issue, several systems have been developed for quick and efficient micronucleus counting, including flow cytometry and automated detection based on specialized software and detection systems that analyze images. RESULTS Here, we present a simple and effective method for automated micronucleus counting using image recognition technology. Our process involves separating the RGB channels in a color micrograph of cells stained with acridine orange. The cell nuclei and micronuclei were detected by scaling the G image, whereas the cytoplasm was recognized from a composite image of the R and G images. Finally, we identified cells with overlapping cytoplasm and micronuclei as micronucleated cells, and the application displayed the number of micronucleated cells and the total number of cells. Our method yielded results that were comparable to manually measured values. CONCLUSIONS Our micronucleus detection (MN/cell detection software) system can accurately detect the total number of cells and micronucleus-forming cells in microscopic images with the same level of precision as achieved through manual counting. The accuracy of micronucleus numbers depends on the cell staining conditions; however, the software has options by which users can easily manually optimize parameters such as threshold, denoise, and binary to achieve the best results. The optimization process is easy to handle and requires less effort, making it an efficient way to obtain accurate results.
Collapse
Affiliation(s)
- Hiromi Yoda
- Biomedical Research Center, Kanagawa Institute of Technology, 1030 Shimo-Ogino, Atsugi, Kanagawa, 243-0292, Japan
- Department of Applied Biosciences, Kanagawa Institute of Technology, Atsugi, Japan
| | - Kazuya Abe
- Biomedical Research Center, Kanagawa Institute of Technology, 1030 Shimo-Ogino, Atsugi, Kanagawa, 243-0292, Japan
- Department of Electrical and Electronic Engineering, Kanagawa Institute of Technology, Atsugi, Japan
| | - Hideya Takeo
- Biomedical Research Center, Kanagawa Institute of Technology, 1030 Shimo-Ogino, Atsugi, Kanagawa, 243-0292, Japan
- Department of Electrical and Electronic Engineering, Kanagawa Institute of Technology, Atsugi, Japan
| | - Takeji Takamura-Enya
- Biomedical Research Center, Kanagawa Institute of Technology, 1030 Shimo-Ogino, Atsugi, Kanagawa, 243-0292, Japan.
- Department of Applied Chemistry, Kanagawa Institute of Technology, 1030 Shimo-Ogino, Atsugi, Kanagawa, 243-0292, Japan.
| | - Ayumi Koike-Takeshita
- Biomedical Research Center, Kanagawa Institute of Technology, 1030 Shimo-Ogino, Atsugi, Kanagawa, 243-0292, Japan
- Department of Applied Biosciences, Kanagawa Institute of Technology, Atsugi, Japan
| |
Collapse
|
2
|
In Vitro Hemocompatibility and Genotoxicity Evaluation of Dual-Labeled [99mTc]Tc-FITC-Silk Fibroin Nanoparticles for Biomedical Applications. Pharmaceuticals (Basel) 2023. [DOI: 10.3390/ph16020248] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/10/2023] Open
Abstract
Nuclear imaging is a highly sensitive and noninvasive imaging technique that has become essential for medical diagnosis. The use of radiolabeled nanomaterials capable of acting as imaging probes has shown rapid development in recent years as a powerful, highly sensitive, and noninvasive tool. In addition, quantitative single-photon emission computed tomography (SPECT) images performed by incorporating radioisotopes into nanoparticles (NPs) might improve the evaluation and the validation of potential clinical treatments. In this work, we present a direct method for [99mTc]Tc-radiolabeling of FITC-tagged silk fibroin nanoparticles (SFN). NPs were characterized by means of dynamic light scattering and scanning electron microscopy. In vitro studies were carried out, including the evaluation of stability in biological media and the evaluation of hemocompatibility and genotoxicity using the cytokinesis block micronucleus (CBMN) assay. The radiolabeling method was reproducible and robust with high radiolabeling efficiency (∼95%) and high stability in biological media. Hydrodynamic properties of the radiolabeled NPs remain stable after dual labeling. The interaction of SFN with blood elicits a mild host response, as expected. Furthermore, CBMN assay did not show genotoxicity induced by [99mTc]Tc-FITC-SFN under the described conditions. In conclusion, a feasible and robust dual-labeling method has been developed whose applicability has been demonstrated in vitro, showing its value for further investigations of silk fibroin NPs biodistribution in vivo.
Collapse
|
3
|
Wang Q, Rodrigues MA, Repin M, Pampou S, Beaton-Green LA, Perrier J, Garty G, Brenner DJ, Turner HC, Wilkins RC. Automated Triage Radiation Biodosimetry: Integrating Imaging Flow Cytometry with High-Throughput Robotics to Perform the Cytokinesis-Block Micronucleus Assay. Radiat Res 2019; 191:342-351. [PMID: 30779694 DOI: 10.1667/rr15243.1] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
The cytokinesis-block micronucleus (CBMN) assay has become a fully-validated and standardized method for radiation biodosimetry. The assay is typically performed using microscopy, which is labor intensive, time consuming and impractical after a large-scale radiological/nuclear event. Imaging flow cytometry (IFC), which combines the statistical power of traditional flow cytometry with the sensitivity and specificity of microscopy, has been recently used to perform the CBMN assay. Since this technology is capable of automated sample acquisition and multi-file analysis, we have integrated IFC into our Rapid Automated Biodosimetry Technology (RABiT-II). Assay development and optimization studies were designed to increase the yield of binucleated cells (BNCs), and improve data acquisition and analysis templates to increase the speed and accuracy of image analysis. Human peripheral blood samples were exposed ex vivo with up to 4 Gy of c rays at a dose rate of 0.73 Gy/min. After irradiation, samples were transferred to microtubes (total volume of 1 ml including blood and media) and organized into a standard 8 × 12 plate format. Sample processing methods were modified by increasing the blood-to-media ratio, adding hypotonic solution prior to cell fixation and optimizing nuclear DRAQ5 staining, leading to an increase of 81% in BNC yield. Modification of the imaging processing algorithms within IFC software also improved BNC and MN identification, and reduced the average time of image analysis by 78%. Finally, 50 ll of irradiated whole blood was cultured with 200 ll of media in 96-well plates. All sample processing steps were performed automatically using the RABiT-II cell: :explorer robotic system adopting the optimized IFC-CBMN assay protocol. The results presented here detail a novel, high-throughput RABiT-IFC CBMN assay that possesses the potential to increase capacity for triage biodosimetry during a large-scale radiological/nuclear event.
Collapse
Affiliation(s)
- Qi Wang
- a Center for Radiological Research, Columbia University Medical Center, New York, New York 10032
| | | | - Mikhail Repin
- a Center for Radiological Research, Columbia University Medical Center, New York, New York 10032
| | - Sergey Pampou
- b Columbia Genome Center High-Throughput Screening Facility, Columbia University Medical Center, New York, New York 10032
| | - Lindsay A Beaton-Green
- d Consumer and Clinical Radiation Protection Bureau, Health Canada, Ottawa K1A 1C1, Canada
| | - Jay Perrier
- a Center for Radiological Research, Columbia University Medical Center, New York, New York 10032
| | - Guy Garty
- a Center for Radiological Research, Columbia University Medical Center, New York, New York 10032
| | - David J Brenner
- a Center for Radiological Research, Columbia University Medical Center, New York, New York 10032
| | - Helen C Turner
- a Center for Radiological Research, Columbia University Medical Center, New York, New York 10032
| | - Ruth C Wilkins
- d Consumer and Clinical Radiation Protection Bureau, Health Canada, Ottawa K1A 1C1, Canada
| |
Collapse
|
4
|
Garcia-Käufer M, Haddad T, Bergheim M, Gminski R, Gupta P, Mathur N, Kümmerer K, Mersch-Sundermann V. Genotoxic effect of ciprofloxacin during photolytic decomposition monitored by the in vitro micronucleus test (MNvit) in HepG2 cells. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2012; 19:1719-27. [PMID: 22161117 DOI: 10.1007/s11356-011-0686-y] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/17/2011] [Accepted: 11/28/2011] [Indexed: 05/13/2023]
Abstract
PURPOSE Ciprofloxacin (CIP), a broad-spectrum, second-generation fluoroquinolone, has frequently been found in hospital wastewaters and effluents of sewage treatment plants. CIP is scarcely biodegradable, has toxic effects on microorganisms and is photosensitive. The aim of this study was to assess the genotoxic potential of CIP in human HepG2 liver cells during photolysis. METHODS Photolysis of CIP was performed in aqueous solution by irradiation with an Hg lamp, and transformation products were monitored by HPLC-MS/MS and by the determination of dissolved organic carbon (DOC). The cytotoxicity and genotoxicity of CIP and of the irradiated samples were determined after 24 h of exposure using the WST-1 assay and the in vitro micronucleus (MN) test in HepG2 cells. RESULTS The concentration of CIP decreased during photolysis, whereas the content of DOC remained unchanged. CIP and its transformation products were not cytotoxic towards HepG2 cells. A concentration-dependent increase of MN frequencies was observed for the parent compound CIP (lowest observed effect level, 1.2 μmol L(-1)). Furthermore, CIP and the irradiated samples were found to be genotoxic with a significant increase relative to the parent compound after 32 min (P < 0.05). A significant reduction of genotoxicity was found after 2 h of irradiation (P < 0.05). CONCLUSIONS Photolytic decomposition of aqueous CIP leads to genotoxic transformation products. This proves that irradiated samples of CIP are able to exert heritable genotoxic effects on human liver cells in vitro. Therefore, photolysis as a technique for wastewater treatment needs to be evaluated in detail in further studies, not only for CIP but in general.
Collapse
Affiliation(s)
- Manuel Garcia-Käufer
- Department of Environmental Health Sciences, University Medical Centre Freiburg, Freiburg, Germany.
| | | | | | | | | | | | | | | |
Collapse
|
5
|
Hreljac I, Filipic M. Organophosphorus pesticides enhance the genotoxicity of benzo(a)pyrene by modulating its metabolism. Mutat Res 2009; 671:84-92. [PMID: 19800895 DOI: 10.1016/j.mrfmmm.2009.09.011] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2009] [Revised: 09/19/2009] [Accepted: 09/25/2009] [Indexed: 10/20/2022]
Abstract
Organophosphorus compounds (OPs) are widely used as pesticides. They act primarily as neurotoxins, but there is increasing evidence for secondary mechanisms of their toxicity. We have shown that the model OPs, methyl parathion (PT) and methyl paraoxon (PO), are genotoxic. Benzo(a)pyrene (BaP) is a widespread environmental genotoxin found in cigarette smoke, polluted air and grilled food. As people are constantly exposed to low concentrations of BaP and also to OPs, the aim of this study was to determine possible synergistic effects of PT and PO on BaP-induced genotoxicity. In the bacterial reverse mutation assay, PT and PO increased the number of BaP-induced mutations. The comet assay with human hepatoma HepG2 cells showed that BaP-induced DNA strand breaks were increased by PT but slightly decreased by PO. Using the acellular comet assay with UVC-induced DNA strand breaks, we observed a decrease in DNA migration, indicating that OPs cause cross-linking, thus interfering with comet assay results. In HepG2 cells the two OPs induced micronuclei formation at very low doses (0.01 microg/ml) and together with BaP, a more than additive increase of micronuclei was observed, confirming their co-genotoxic effect. We demonstrated for the first time that PT and PO modulate the metabolic activation of BaP. Addition of PT or PO increased aldo-keto reductase (AKR1C1/2) levels in the presence of BaP, while cytochrome 1A (CYP1A) mRNA expression and activity were decreased. Further, specific inhibition of CYP1A had no effect on BaP or OP+BaP-induced micronuclei, whereas inhibition of AKR1C dramatically decreased the number of micronuclei induced by BaP or OP+BaP. Based on these results we propose that co-genotoxicity results from OPs mediated modulation of BaP metabolism, favouring the induction of AKR1C enzymes known to catalyse the formation of DNA reactive BaP o-quinones and the production of reactive oxygen species.
Collapse
Affiliation(s)
- Irena Hreljac
- Department of Genetic Toxicology and Cancer Biology, National Institute of Biology, Vecna pot 111, Ljubljana, Slovenia
| | | |
Collapse
|