1
|
Devis L, Catry E, Honore PM, Mansour A, Lippi G, Mullier F, Closset M. Interventions to improve appropriateness of laboratory testing in the intensive care unit: a narrative review. Ann Intensive Care 2024; 14:9. [PMID: 38224401 PMCID: PMC10789714 DOI: 10.1186/s13613-024-01244-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2023] [Accepted: 01/03/2024] [Indexed: 01/16/2024] Open
Abstract
Healthcare expenses are increasing, as is the utilization of laboratory resources. Despite this, between 20% and 40% of requested tests are deemed inappropriate. Improper use of laboratory resources leads to unwanted consequences such as hospital-acquired anemia, infections, increased costs, staff workload and patient stress and discomfort. The most unfavorable consequences result from unnecessary follow-up tests and treatments (overuse) and missed or delayed diagnoses (underuse). In this context, several interventions have been carried out to improve the appropriateness of laboratory testing. To date, there have been few published assessments of interventions specific to the intensive care unit. We reviewed the literature for interventions implemented in the ICU to improve the appropriateness of laboratory testing. We searched literature from 2008 to 2023 in PubMed, Embase, Scopus, and Google Scholar databases between April and June 2023. Five intervention categories were identified: education and guidance (E&G), audit and feedback, gatekeeping, computerized physician order entry (including reshaping of ordering panels), and multifaceted interventions (MFI). We included a sixth category exploring the potential role of artificial intelligence and machine learning (AI/ML)-based assisting tools in such interventions. E&G-based interventions and MFI are the most frequently used approaches. MFI is the most effective type of intervention, and shows the strongest persistence of effect over time. AI/ML-based tools may offer valuable assistance to the improvement of appropriate laboratory testing in the near future. Patient safety outcomes are not impaired by interventions to reduce inappropriate testing. The literature focuses mainly on reducing overuse of laboratory tests, with only one intervention mentioning underuse. We highlight an overall poor quality of methodological design and reporting and argue for standardization of intervention methods. Collaboration between clinicians and laboratory staff is key to improve appropriate laboratory utilization. This article offers practical guidance for optimizing the effectiveness of an intervention protocol designed to limit inappropriate use of laboratory resources.
Collapse
Affiliation(s)
- Luigi Devis
- Department of Laboratory Medicine, Biochemistry, CHU UCL Namur, Université catholique de Louvain, Yvoir, Belgium
| | - Emilie Catry
- Department of Laboratory Medicine, Biochemistry, CHU UCL Namur, Université catholique de Louvain, Yvoir, Belgium
- Institute for Experimental and Clinical Research (IREC), Pôle Mont Godinne (MONT), UCLouvain, Yvoir, Belgium
| | - Patrick M Honore
- Department of Intensive Care, CHU UCL Namur, Université catholique de Louvain, Yvoir, Belgium
| | - Alexandre Mansour
- Department of Anesthesia and Critical Care, Pontchaillou University Hospital of Rennes, Rennes, France
- IRSET-INSERM-1085, Univ Rennes, Rennes, France
| | - Giuseppe Lippi
- Section of Clinical Biochemistry and School of Medicine, University Hospital of Verona, Verona, Italy
| | - François Mullier
- Department of Laboratory Medicine, Hematology, CHU UCL Namur, Université catholique de Louvain, Yvoir, Belgium
- Namur Thrombosis and Hemostasis Center (NTHC), Namur Research Institute for Life Sciences (NARILIS), Namur, Belgium
- Institute for Experimental and Clinical Research (IREC), Pôle Mont Godinne (MONT), UCLouvain, Yvoir, Belgium
| | - Mélanie Closset
- Department of Laboratory Medicine, Biochemistry, CHU UCL Namur, Université catholique de Louvain, Yvoir, Belgium.
- Institute for Experimental and Clinical Research (IREC), Pôle Mont Godinne (MONT), UCLouvain, Yvoir, Belgium.
| |
Collapse
|
2
|
Anticoagulation Monitoring with Activated Partial ThromboPlastin Time and Anti-Xa Activity in Intensive Care Unit Patients: Interest of Thrombin Generation Assay. Int J Mol Sci 2022; 23:ijms231911219. [PMID: 36232517 PMCID: PMC9570449 DOI: 10.3390/ijms231911219] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2022] [Revised: 09/20/2022] [Accepted: 09/22/2022] [Indexed: 11/30/2022] Open
Abstract
Current guidelines recommend monitoring the anticoagulant effect of unfractionated heparin (UFH) by measuring anti-Xa activity rather than activated partial thromboplastin time (aPTT) in intensive care unit (ICU) patients. The primary objective of this study was to evaluate the correlation of aPTT, anti-Xa activity, and thrombin generation in UFH-treated ICU patients. A prospective observational pilot study was conducted in adult surgical ICU patients treated with UFH. aPTT and anti-Xa activity were monitored daily. The therapeutic target was aPTT between 50 s and 84 s, and/or anti-Xa between 0.3 and 0.7 U/mL. Correlation among aPTT, anti-Xa activity, and thrombin generation was determined by measuring endogenous thrombin potential (ETP), with the inflammatory response evaluated. C-reactive protein (CRP) was used as a marker of inflammatory response. The plasma of 107 samples from 30 ICU patients was analyzed. The correlation between aPTT and anti-Xa activity was 0.66, CI95% [0.54;0.76] (p < 0.0001). Although thrombin generation, aPTT, and anti-Xa were correlated with inflammatory responses, the correlation was higher with thrombin generation and anti-Xa activity compared to aPTT. When aPTT was in a therapeutic range, a low thrombin generation was observed but was 50% inhibited when anti-Xa was in a therapeutic range. Coagulation testing with aPTT, anti-Xa correlated with thrombin generation. A 50% decrease in thrombin generation was observed when anti-Xa was within a therapeutic range. Further work is needed to evaluate coagulation biomarker responses and clinical outcomes in specific ICU populations.
Collapse
|