1
|
Li L, Rae AI, Burchiel KJ. A Meta-Analysis of Medication Reduction and Motor Outcomes After Awake Versus Asleep Deep Brain Stimulation for Parkinson Disease. Neurosurgery 2024:00006123-990000000-01322. [PMID: 39194217 DOI: 10.1227/neu.0000000000003138] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2024] [Accepted: 07/06/2024] [Indexed: 08/29/2024] Open
Abstract
BACKGROUND AND OBJECTIVES There remains significant debate regarding the performance of deep brain stimulation (DBS) procedures for Parkinson disease (PD) under local or general anesthesia. The aim of this meta-analysis was to compare the clinical outcomes between "asleep" DBS (general anesthesia) and "awake" DBS (local anesthesia) for PD. METHODS We conducted a comprehensive literature review of all published studies on DBS for PD following PRISMA guideline on PubMed and Cochrane library from January 2004 to April 2023. Inclusion criteria included cohort ≥15 patients, clinical outcomes data which included Unified Parkinson's Disease Rating Scale (UPDRS) score and levodopa equivalent daily dosage (LEDD), and ≥3 months of follow-up. Analysis was conducted using Stata software. RESULTS There were 18 articles that met inclusion criteria. On meta-analysis, there were no significant differences between awake or asleep DBS with regard to percent change in UPDRS III "off" med/"on" DBS condition ( P = .6) and LEDD score ( P = .99). On subgroup analysis, we found that the choice of target had no significant effect on improvement of UPDRS III ( P = 1.0) or LEDD ( P = .99) change for the asleep vs awake operative approach. There were also no statistically significant differences between microelectrode recording (MER) use and no MER use in postoperative UPDRS III ( P = 1.0) or LEDD improvement ( P = .90) between awake and asleep surgery. CONCLUSION There was no significant difference in the primary motor outcomes and LEDD improvement between asleep vs awake DBS. The variables of target selection and MER use had no statistically significant impact on outcome. We find that asleep techniques are both safe and effective compared with the awake technique.
Collapse
Affiliation(s)
- Luyuan Li
- Department of Neurological Surgery, Oregon Health & Science University, Portland , Oregon , USA
| | | | | |
Collapse
|
2
|
Hvingelby VS, Pavese N. Surgical Advances in Parkinson's Disease. Curr Neuropharmacol 2024; 22:1033-1046. [PMID: 36411569 PMCID: PMC10964101 DOI: 10.2174/1570159x21666221121094343] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2022] [Revised: 10/24/2022] [Accepted: 10/29/2022] [Indexed: 11/23/2022] Open
Abstract
While symptomatic pharmacological therapy remains the main therapeutic strategy for Parkinson's disease (PD), over the last two decades, surgical approaches have become more commonly used to control levodopa-induced motor complications and dopamine-resistant and non-motor symptoms of PD. In this paper, we discuss old and new surgical treatments for PD and the many technological innovations in this field. We have initially reviewed the relevant surgical anatomy as well as the pathological signaling considered to be the underlying cause of specific symptoms of PD. Subsequently, early attempts at surgical symptom control will be briefly reviewed. As the most well-known surgical intervention for PD is deep brain stimulation, this subject is discussed at length. As deciding on whether a patient stands to benefit from DBS can be quite difficult, the different proposed paradigms for precisely this are covered. Following this, the evidence regarding different targets, especially the subthalamic nucleus and internal globus pallidus, is reviewed as well as the evidence for newer proposed targets for specific symptoms. Due to the rapidly expanding nature of knowledge and technological capabilities, some of these new and potential future capabilities are given consideration in terms of their current and future use. Following this, we have reviewed newer treatment modalities, especially magnetic resonance-guided focused ultrasound and other potential surgical therapies, such as spinal cord stimulation for gait symptoms and others. As mentioned, the field of surgical alleviation of symptoms of PD is undergoing a rapid expansion, and this review provides a general overview of the current status and future directions in the field.
Collapse
Affiliation(s)
- Victor S. Hvingelby
- Department of Clinical Medicine, Nuclear Medicine and PET Center, Aarhus University, Aarhus, Denmark
| | - Nicola Pavese
- Department of Clinical Medicine, Nuclear Medicine and PET Center, Aarhus University, Aarhus, Denmark
- Clinical Ageing Research Unit, Newcastle Upon Tyne, Newcastle University, United Kingdom
| |
Collapse
|
3
|
Li J, Guan X, Wu Q, He C, Zhang W, Lin X, Liu C, Wei H, Xu X, Zhang Y. Direct localization and delineation of human pedunculopontine nucleus based on a self-supervised magnetic resonance image super-resolution method. Hum Brain Mapp 2023; 44:3781-3794. [PMID: 37186095 DOI: 10.1002/hbm.26311] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2022] [Revised: 03/24/2023] [Accepted: 03/30/2023] [Indexed: 05/17/2023] Open
Abstract
The pedunculopontine nucleus (PPN) is a small brainstem structure and has attracted attention as a potentially effective deep brain stimulation (DBS) target for the treatment of Parkinson's disease (PD). However, the in vivo location of PPN remains poorly described and barely visible on conventional structural magnetic resonance (MR) images due to a lack of high spatial resolution and tissue contrast. This study aims to delineate the PPN on a high-resolution (HR) atlas and investigate the visibility of the PPN in individual quantitative susceptibility mapping (QSM) images. We combine a recently constructed Montreal Neurological Institute (MNI) space unbiased QSM atlas (MuSus-100), with an implicit representation-based self-supervised image super-resolution (SR) technique to achieve an atlas with improved spatial resolution. Then guided by a myelin staining histology human brain atlas, we localize and delineate PPN on the atlas with improved resolution. Furthermore, we examine the feasibility of directly identifying the approximate PPN location on the 3.0-T individual QSM MR images. The proposed SR network produces atlas images with four times the higher spatial resolution (from 1 to 0.25 mm isotropic) without a training dataset. The SR process also reduces artifacts and keeps superb image contrast for further delineating small deep brain nuclei, such as PPN. Using the myelin staining histological atlas as guidance, we first identify and annotate the location of PPN on the T1-weighted (T1w)-QSM hybrid MR atlas with improved resolution in the MNI space. Then, we relocate and validate that the optimal targeting site for PPN-DBS is at the middle-to-caudal part of PPN on our atlas. Furthermore, we confirm that the PPN region can be identified in a set of individual QSM images of 10 patients with PD and 10 healthy young adults. The contrast ratios of the PPN to its adjacent structure, namely the medial lemniscus, on images of different modalities indicate that QSM substantially improves the visibility of the PPN both in the atlas and individual images. Our findings indicate that the proposed SR network is an efficient tool for small-size brain nucleus identification. HR QSM is promising for improving the visibility of the PPN. The PPN can be directly identified on the individual QSM images acquired at the 3.0-T MR scanners, facilitating a direct targeting of PPN for DBS surgery.
Collapse
Affiliation(s)
- Jun Li
- School of Information Science and Technology, ShanghaiTech University, Shanghai, China
| | - Xiaojun Guan
- Department of Radiology, The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Qing Wu
- School of Information Science and Technology, ShanghaiTech University, Shanghai, China
| | - Chenyu He
- School of Information Science and Technology, ShanghaiTech University, Shanghai, China
| | - Weimin Zhang
- School of Information Science and Technology, ShanghaiTech University, Shanghai, China
| | - Xiyue Lin
- School of Information Science and Technology, ShanghaiTech University, Shanghai, China
| | - Chunlei Liu
- Department of Electrical Engineering and Computer Science, University of California at Berkeley, Berkeley, California, USA
- Helen Wills Neuroscience Institute, University of California at Berkeley, Berkeley, California, USA
| | - Hongjiang Wei
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
- Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai, China
| | - Xiaojun Xu
- Department of Radiology, The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Yuyao Zhang
- School of Information Science and Technology, ShanghaiTech University, Shanghai, China
- Ihuman Institute, ShanghaiTech University, Shanghai, China
| |
Collapse
|
4
|
Rusheen AE, Goyal A, Owen RL, Berning EM, Bothun DT, Giblon RE, Blaha CD, Welker KM, Huston J, Bennet KE, Oh Y, Fagan AJ, Lee KH. The development of ultra-high field MRI guidance technology for neuronavigation. J Neurosurg 2022; 137:1265-1277. [PMID: 35334465 PMCID: PMC10193481 DOI: 10.3171/2021.11.jns211078] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2021] [Accepted: 11/19/2021] [Indexed: 11/06/2022]
Abstract
OBJECTIVE Magnetic resonance imaging at 7T offers improved image spatial and contrast resolution for visualization of small brain nuclei targeted in neuromodulation. However, greater image geometric distortion and a lack of compatible instrumentation preclude implementation. In this report, the authors detail the development of a stereotactic image localizer and accompanying imaging sequences designed to mitigate geometric distortion, enabling accurate image registration and surgical planning of basal ganglia nuclei. METHODS Magnetization-prepared rapid acquisition with gradient echo (MPRAGE), fast gray matter acquisition T1 inversion recovery (FGATIR), T2-weighted, and T2*-weighted sequences were optimized for 7T in 9 human subjects to visualize basal ganglia nuclei, minimize image distortion, and maximize target contrast-to-noise and signal-to-noise ratios. Extracranial spatial distortions were mapped to develop a skull-contoured image localizer embedded with spherical silicone fiducials for improved MR image registration and target guidance. Surgical plan accuracy testing was initially performed in a custom-developed MRI phantom (n = 5 phantom studies) and finally in a human trial. RESULTS MPRAGE and T2*-weighted sequences had the best measures among global measures of image quality (3.8/4, p < 0.0001; and 3.7/4, p = 0.0002, respectively). Among basal ganglia nuclei, FGATIR outperformed MPRAGE for globus pallidus externus (GPe) visualization (2.67/4 vs 1.78/4, p = 0.008), and FGATIR, T2-weighted imaging, and T2*-weighted imaging outperformed MPRAGE for substantia nigra visualization (1.44/4 vs 2.56/4, p = 0.04; vs 2.56/4, p = 0.04; vs 2.67/4, p = 0.003). Extracranial distortion was lower in the head's midregion compared with the base and apex ( 1.17-1.33 mm; MPRAGE and FGATIR, p < 0.0001; T2-weighted imaging, p > 0.05; and T2*-weighted imaging, p = 0.013). Fiducial placement on the localizer in low distortion areas improved image registration (fiducial registration error, 0.79-1.19 mm; p < 0.0001) and targeting accuracy (target registration error, 0.60-1.09 mm; p = 0.04). Custom surgical software and the refined image localizer enabled successful surgical planning in a human trial (fiducial registration error = 1.0 mm). CONCLUSIONS A skull-contoured image localizer that accounts for image distortion is necessary to enable high-accuracy 7T imaging-guided targeting for surgical neuromodulation. These results may enable improved clinical efficacy for the treatment of neurological disease.
Collapse
Affiliation(s)
- Aaron E. Rusheen
- Department of Neurologic Surgery, Mayo Clinic, Rochester
- Medical Scientist Training Program, Mayo Clinic, Rochester
| | - Abhinav Goyal
- Department of Neurologic Surgery, Mayo Clinic, Rochester
- Medical Scientist Training Program, Mayo Clinic, Rochester
| | - Robert L. Owen
- Mayo Clinic Alix School of Medicine, Mayo Clinic, Rochester
| | | | - Dane T. Bothun
- Department of Neurologic Surgery, Mayo Clinic, Rochester
| | - Rachel E. Giblon
- Kern Center for the Science of Health Care Delivery, Mayo Clinic, Rochester
| | | | | | - John Huston
- Department of Radiology, Mayo Clinic, Rochester; and
| | | | - Yoonbae Oh
- Department of Neurologic Surgery, Mayo Clinic, Rochester
| | - Andrew J. Fagan
- Department of Radiology, Mayo Clinic, Rochester; and
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, Minnesota
| | - Kendall H. Lee
- Department of Neurologic Surgery, Mayo Clinic, Rochester
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, Minnesota
| |
Collapse
|
5
|
Su CY, Wong AMC, Chang CC, Tu PH, Chen CC, Yeh CH. Quantitative Analysis for the Delineation of the Subthalamic Nuclei on Three-Dimensional Stereotactic MRI Before Deep Brain Stimulation Surgery for Medication-Refractory Parkinson’s Disease. Front Hum Neurosci 2022; 16:829198. [PMID: 35273486 PMCID: PMC8902041 DOI: 10.3389/fnhum.2022.829198] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2021] [Accepted: 01/19/2022] [Indexed: 11/13/2022] Open
Abstract
Delineation of the subthalamic nuclei (STN) on MRI is critical for deep brain stimulation (DBS) surgery in patients with Parkinson’s disease (PD). We propose this retrospective cohort study for quantitative analysis of MR signal-to-noise ratio (SNR), contrast, and signal difference-to-noise ratio (SDNR) of the STN on pre-operative three-dimensional (3D) stereotactic MRI in patients with medication-refractory PD. Forty-five consecutive patients with medication-refractory PD who underwent STN-DBS surgery in our hospital from January 2018 to June 2021 were included in this study. All patients had whole-brain 3D MRI, including T2-weighted imaging (T2WI), T2-weighted fluid-attenuated inversion recovery (FLAIR), and susceptibility-weighted imaging (SWI), at 3.0 T scanner for stereotactic navigation. The signal intensities of the STN, corona radiata, and background noise were obtained after placing regions of interest (ROIs) on corresponding structures. Quantitative comparisons of SNR, contrast, and SDNR of the STN between MR pulse sequences, including the T2WI, FLAIR, and SWI. Subgroup analysis regarding patients’ sex, age, and duration of treatment. We used one-way repeated measures analysis of variance for quantitative comparisons of SNR, contrast, and SDNR of the STN between different MR pulse sequences, and we also used the dependent t-test for the post hoc tests. In addition, we used Mann–Whitney U test for subgroup analyses. Both the contrast (0.33 ± 0.07) and SDNR (98.65 ± 51.37) were highest on FLAIR (all p < 0.001). The SNR was highest on SWI (276.16 ± 115.5), and both the SNR (94.23 ± 31.63) and SDNR (32.14 ± 17.23) were lowest on T2WI. Subgroup analyses demonstrated significantly lower SDNR on SWI for patients receiving medication treatment for ≥13 years (p = 0.003). In conclusion, on 3D stereotactic MRI of medication-refractory PD patients, the contrast and SDNR for the STN are highest on FLAIR, suggesting the optimal delineation of STN on FLAIR.
Collapse
Affiliation(s)
- Chun-Yu Su
- Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital, Linkou, Taiwan
- College of Medicine, Chang Gung University, Taoyuan, Taiwan
| | - Alex Mun-Ching Wong
- Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital, Linkou, Taiwan
- College of Medicine, Chang Gung University, Taoyuan, Taiwan
- Department of Diagnostic Radiology, Chang Gung Memorial Hospital, Keelung, Taiwan
| | - Chih-Chen Chang
- Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital, Linkou, Taiwan
- College of Medicine, Chang Gung University, Taoyuan, Taiwan
| | - Po-Hsun Tu
- College of Medicine, Chang Gung University, Taoyuan, Taiwan
- Department of Neurosurgery, Chang Gung Memorial Hospital, Linkou, Taiwan
| | - Chiung Chu Chen
- College of Medicine, Chang Gung University, Taoyuan, Taiwan
- Department of Neurology, Chang Gung Memorial Hospital, Linkou, Taiwan
- Neuroscience Research Center, Chang Gung Memorial Hospital, Linkou, Taiwan
| | - Chih-Hua Yeh
- Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital, Linkou, Taiwan
- College of Medicine, Chang Gung University, Taoyuan, Taiwan
- *Correspondence: Chih-Hua Yeh,
| |
Collapse
|
6
|
Boutet A, Loh A, Chow CT, Taha A, Elias GJB, Neudorfer C, Germann J, Paff M, Zrinzo L, Fasano A, Kalia SK, Steele CJ, Mikulis D, Kucharczyk W, Lozano AM. A literature review of magnetic resonance imaging sequence advancements in visualizing functional neurosurgery targets. J Neurosurg 2021; 135:1445-1458. [PMID: 33770759 DOI: 10.3171/2020.8.jns201125] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2020] [Accepted: 08/13/2020] [Indexed: 11/06/2022]
Abstract
OBJECTIVE Historically, preoperative planning for functional neurosurgery has depended on the indirect localization of target brain structures using visible anatomical landmarks. However, recent technological advances in neuroimaging have permitted marked improvements in MRI-based direct target visualization, allowing for refinement of "first-pass" targeting. The authors reviewed studies relating to direct MRI visualization of the most common functional neurosurgery targets (subthalamic nucleus, globus pallidus, and thalamus) and summarize sequence specifications for the various approaches described in this literature. METHODS The peer-reviewed literature on MRI visualization of the subthalamic nucleus, globus pallidus, and thalamus was obtained by searching MEDLINE. Publications examining direct MRI visualization of these deep brain stimulation targets were included for review. RESULTS A variety of specialized sequences and postprocessing methods for enhanced MRI visualization are in current use. These include susceptibility-based techniques such as quantitative susceptibility mapping, which exploit the amount of tissue iron in target structures, and white matter attenuated inversion recovery, which suppresses the signal from white matter to improve the distinction between gray matter nuclei. However, evidence confirming the superiority of these sequences over indirect targeting with respect to clinical outcome is sparse. Future targeting may utilize information about functional and structural networks, necessitating the use of resting-state functional MRI and diffusion-weighted imaging. CONCLUSIONS Specialized MRI sequences have enabled considerable improvement in the visualization of common deep brain stimulation targets. With further validation of their ability to improve clinical outcomes and advances in imaging techniques, direct visualization of targets may play an increasingly important role in preoperative planning.
Collapse
Affiliation(s)
- Alexandre Boutet
- 1University Health Network, Toronto
- 2Joint Department of Medical Imaging, University of Toronto, Ontario, Canada
| | | | | | | | | | | | | | | | - Ludvic Zrinzo
- 3Functional Neurosurgery Unit, Department of Clinical and Movement Neurosciences, University College London, Queen Square Institute of Neurology, The National Hospital for Neurology and Neurosurgery, London, United Kingdom
| | - Alfonso Fasano
- 4Edmond J. Safra Program in Parkinson's Disease, Morton and Gloria Shulman Movement Disorders Clinic, Toronto Western Hospital, University Health Network, Division of Neurology, University of Toronto
- 5Krembil Brain Institute, Toronto, Ontario
| | | | - Christopher J Steele
- 6Department of Psychology, Concordia University, Montreal, Quebec, Canada; and
- 7Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany
| | - David Mikulis
- 1University Health Network, Toronto
- 2Joint Department of Medical Imaging, University of Toronto, Ontario, Canada
| | - Walter Kucharczyk
- 1University Health Network, Toronto
- 2Joint Department of Medical Imaging, University of Toronto, Ontario, Canada
| | | |
Collapse
|
7
|
Asriyants SV, Tomskiy AA, Gamaleya AA, Pronin IN. [Deep brain stimulation of the subthalamic nucleus for parkinson's disease: awake vs asleep]. ZHURNAL VOPROSY NEĬROKHIRURGII IMENI N. N. BURDENKO 2021; 85:117-121. [PMID: 34714012 DOI: 10.17116/neiro202185051117] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
BACKGROUND Deep brain stimulation (DBS) of the subthalamic nucleus (STN) is known to be an effective and safe neurosurgical procedure for Parkinson's disease (PD). Traditionally, awake implantation of stimulation system is carried out using microelectrode registration and intraoperative stimulation. Development of neuroimaging technologies enables direct STN imaging. Therefore, asleep surgery without additional intraoperative verification is possible. This approach reduces surgery time and can potentially decrease the incidence of hemorrhagic and infectious complications. The advantages of one method or another are being discussed. OBJECTIVE To assess the benefits and limitations of various methods for DBS system implantation for bilateral STN stimulation, to study the issues of stereotaxic accuracy, efficiency and safety of asleep and awake electrode implantation into STN. MATERIAL AND METHODS We reviewed the articles published in the PubMed database. Searching algorithm included the following keywords: «asleep DBS», «Parkinson's disease», «subthalamic nucleus», «3T MRI», «SWI», «SWAN». RESULTS There were 31 articles devoted to asleep DBS of STN including 4 meta-analyses, 3 prospective controlled studies, 13 retrospective controlled studies and 11 studies without a control group. CONCLUSION Asleep implantation of electrodes for DBS of STN can be performed only after a clear imaging of STN boundaries with high-quality MRI.
Collapse
Affiliation(s)
| | - A A Tomskiy
- Burdenko Neurosurgical Center, Moscow, Russia
| | | | - I N Pronin
- Burdenko Neurosurgical Center, Moscow, Russia
| |
Collapse
|
8
|
Bhusal B, Stockmann J, Guerin B, Mareyam A, Kirsch J, Wald LL, Nolt MJ, Rosenow J, Lopez-Rosado R, Elahi B, Golestanirad L. Safety and image quality at 7T MRI for deep brain stimulation systems: Ex vivo study with lead-only and full-systems. PLoS One 2021; 16:e0257077. [PMID: 34492090 PMCID: PMC8423254 DOI: 10.1371/journal.pone.0257077] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2020] [Accepted: 08/23/2021] [Indexed: 11/19/2022] Open
Abstract
Ultra-high field MRI at 7 T can produce much better visualization of sub-cortical structures compared to lower field, which can greatly help target verification as well as overall treatment monitoring for patients with deep brain stimulation (DBS) implants. However, use of 7 T MRI for such patients is currently contra-indicated by guidelines from the device manufacturers due to the safety issues. The aim of this study was to provide an assessment of safety and image quality of ultra-high field magnetic resonance imaging at 7 T in patients with deep brain stimulation implants. We performed experiments with both lead-only and complete DBS systems implanted in anthropomorphic phantoms. RF heating was measured for 43 unique patient-derived device configurations. Magnetic force measurements were performed according to ASTM F2052 test method, and device integrity was assessed before and after experiments. Finally, we assessed electrode artifact in a cadaveric brain implanted with an isolated DBS lead. RF heating remained below 2°C, similar to a fever, with the 95% confidence interval between 0.38°C-0.52°C. Magnetic forces were well below forces imposed by gravity, and thus not a source of concern. No device malfunctioning was observed due to interference from MRI fields. Electrode artifact was most noticeable on MPRAGE and T2*GRE sequences, while it was minimized on T2-TSE images. Our work provides the safety assessment of ultra-high field MRI at 7 T in patients with DBS implants. Our results suggest that 7 T MRI may be performed safely in patients with DBS implants for specific implant models and MRI hardware.
Collapse
Affiliation(s)
- Bhumi Bhusal
- Department of Radiology, Northwestern University, Chicago, IL, United States of America
| | - Jason Stockmann
- Department of Radiology, Harvard Medical School, Boston, MA, United States of America
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Boston, MA, United States of America
| | - Bastien Guerin
- Department of Radiology, Harvard Medical School, Boston, MA, United States of America
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Boston, MA, United States of America
| | - Azma Mareyam
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Boston, MA, United States of America
| | - John Kirsch
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Boston, MA, United States of America
| | - Lawrence L. Wald
- Department of Radiology, Harvard Medical School, Boston, MA, United States of America
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Boston, MA, United States of America
| | - Mark J. Nolt
- Department of Neurosurgery, Northwestern University, Chicago, IL, United States of America
| | - Joshua Rosenow
- Department of Neurosurgery, Northwestern University, Chicago, IL, United States of America
| | - Roberto Lopez-Rosado
- Department of Physical Therapy and Human Movement Sciences, Northwestern University, Chicago, IL, United States of America
| | - Behzad Elahi
- Department of Physical Therapy and Human Movement Sciences, Northwestern University, Chicago, IL, United States of America
| | - Laleh Golestanirad
- Department of Radiology, Northwestern University, Chicago, IL, United States of America
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, United States of America
| |
Collapse
|
9
|
Chen YS, Shu K, Kang HC. Deep Brain Stimulation in Alzheimer's Disease: Targeting the Nucleus Basalis of Meynert. J Alzheimers Dis 2021; 80:53-70. [PMID: 33492288 DOI: 10.3233/jad-201141] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
Alzheimer's disease (AD) is becoming a prevalent disease in the elderly population. Past decades have witnessed the development of drug therapies with varying targets. However, all drugs with a single molecular target fail to reverse or ameliorate AD progression, which ultimately results in cortical and subcortical network dysregulation. Deep brain stimulation (DBS) has been proven effective for the treatment of Parkinson's disease, essential tremor, and other neurological diseases. As such, DBS has also been gradually acknowledged as a potential therapy for AD. The current review focuses on DBS of the nucleus basalis of Meynert (NBM). As a critical component of the cerebral cholinergic system and the Papez circuit in the basal ganglia, the NBM plays an indispensable role in the subcortical regulation of memory, attention, and arousal state, which makes the NBM a promising target for modulation of neural network dysfunction and AD treatment. We summarized the intricate projection relations and functionality of the NBM, current approaches for stereotactic localization and evaluation of the NBM, and the therapeutic effects of NBM-DBS both in patients and animal models. Furthermore, the current shortcomings of NBM-DBS, such as variations in cortical blood flow, increased temperature in the target area, and stimulation-related neural damage, were presented.
Collapse
Affiliation(s)
- Yu-Si Chen
- Department of Neurosurgery, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China
| | - Kai Shu
- Department of Neurosurgery, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China
| | - Hui-Cong Kang
- Department of Neurology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China
| |
Collapse
|
10
|
Cong F, Liu X, Liu CSJ, Xu X, Shen Y, Wang B, Zhuo Y, Yan L. Improved depiction of subthalamic nucleus and globus pallidus internus with optimized high-resolution quantitative susceptibility mapping at 7 T. NMR IN BIOMEDICINE 2020; 33:e4382. [PMID: 32686241 DOI: 10.1002/nbm.4382] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/14/2020] [Revised: 07/03/2020] [Accepted: 07/06/2020] [Indexed: 06/11/2023]
Abstract
The subthalamic nucleus (STN) and globus pallidus internus (GPi) are commonly used targets in deep-brain stimulation (DBS) surgery for the treatment of movement disorders. The success of DBS critically depends on the spatial precision of stimulation. By taking advantage of good contrast between iron-rich deep-brain nuclei and surrounding tissues, quantitative susceptibility mapping (QSM) has shown promise in differentiating the STN and GPi from the adjacent substantia nigra and globus pallidus externus, respectively. Nonlinear morphology-enabled dipole inversion (NMEDI) is a widely used QSM algorithm, but the image quality of reconstructed susceptibility maps relies on the regularization parameter selection. To date, few studies have systematically optimized the regularization parameter at the ultra-high field of 7 T. In this study, we optimized the regularization parameter in NMEDI to improve the depiction of STN and GPi at different spatial resolutions at both 3 T and 7 T. The optimized QSM images were further compared with other susceptibility-based images, including T2*-weighted (T2*w), R2*, susceptibility-weighted, and phase images. QSM showed better depiction of deep-brain nuclei with clearer boundaries compared with the other methods, and 7 T QSM at 0.35 × 0.35 × 1.0 mm3 demonstrated superior performance to the others. Our findings suggest that optimized high-resolution QSM at 7 T allows for improved delineation of deep-brain nuclei with clear and sharp borders between nuclei, which may become a promising tool for DBS nucleus preoperative localization.
Collapse
Affiliation(s)
- Fei Cong
- State Key Laboratory of Brain and Cognitive Science, Beijing MRI Center for Brain Research, Institute of Biophysics, Chinese Academy of Sciences, Beijing, China
- University of Chinese Academy of Sciences, Beijing, China
| | - Xueru Liu
- State Key Laboratory of Brain and Cognitive Science, Beijing MRI Center for Brain Research, Institute of Biophysics, Chinese Academy of Sciences, Beijing, China
- University of Chinese Academy of Sciences, Beijing, China
| | - Chia-Shang Jason Liu
- Department of Radiology, Keck School of Medicine, University of Southern California, Los Angeles, California, USA
| | - Xin Xu
- Department of Neurosurgery, General Hospital of PLA, Beijing, China
| | - Yelong Shen
- Shandong Provincial Hospital affiliated to Shandong First Medical University, Shandong, China
| | - Bo Wang
- State Key Laboratory of Brain and Cognitive Science, Beijing MRI Center for Brain Research, Institute of Biophysics, Chinese Academy of Sciences, Beijing, China
- University of Chinese Academy of Sciences, Beijing, China
| | - Yan Zhuo
- State Key Laboratory of Brain and Cognitive Science, Beijing MRI Center for Brain Research, Institute of Biophysics, Chinese Academy of Sciences, Beijing, China
- University of Chinese Academy of Sciences, Beijing, China
| | - Lirong Yan
- Stevens Neuroimaging and Informatics Institute, Department of Neurology, Keck School of Medicine, University of Southern California, Los Angeles, California, USA
| |
Collapse
|
11
|
Isaacs BR, Keuken MC, Alkemade A, Temel Y, Bazin PL, Forstmann BU. Methodological Considerations for Neuroimaging in Deep Brain Stimulation of the Subthalamic Nucleus in Parkinson's Disease Patients. J Clin Med 2020; 9:E3124. [PMID: 32992558 PMCID: PMC7600568 DOI: 10.3390/jcm9103124] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2020] [Revised: 09/17/2020] [Accepted: 09/25/2020] [Indexed: 12/17/2022] Open
Abstract
Deep brain stimulation (DBS) of the subthalamic nucleus is a neurosurgical intervention for Parkinson's disease patients who no longer appropriately respond to drug treatments. A small fraction of patients will fail to respond to DBS, develop psychiatric and cognitive side-effects, or incur surgery-related complications such as infections and hemorrhagic events. In these cases, DBS may require recalibration, reimplantation, or removal. These negative responses to treatment can partly be attributed to suboptimal pre-operative planning procedures via direct targeting through low-field and low-resolution magnetic resonance imaging (MRI). One solution for increasing the success and efficacy of DBS is to optimize preoperative planning procedures via sophisticated neuroimaging techniques such as high-resolution MRI and higher field strengths to improve visualization of DBS targets and vasculature. We discuss targeting approaches, MRI acquisition, parameters, and post-acquisition analyses. Additionally, we highlight a number of approaches including the use of ultra-high field (UHF) MRI to overcome limitations of standard settings. There is a trade-off between spatial resolution, motion artifacts, and acquisition time, which could potentially be dissolved through the use of UHF-MRI. Image registration, correction, and post-processing techniques may require combined expertise of traditional radiologists, clinicians, and fundamental researchers. The optimization of pre-operative planning with MRI can therefore be best achieved through direct collaboration between researchers and clinicians.
Collapse
Affiliation(s)
- Bethany R. Isaacs
- Integrative Model-based Cognitive Neuroscience Research Unit, University of Amsterdam, 1018 WS Amsterdam, The Netherlands; (A.A.); (P.-L.B.); (B.U.F.)
- Department of Experimental Neurosurgery, Maastricht University Medical Center, 6202 AZ Maastricht, The Netherlands;
| | - Max C. Keuken
- Municipality of Amsterdam, Services & Data, Cluster Social, 1000 AE Amsterdam, The Netherlands;
| | - Anneke Alkemade
- Integrative Model-based Cognitive Neuroscience Research Unit, University of Amsterdam, 1018 WS Amsterdam, The Netherlands; (A.A.); (P.-L.B.); (B.U.F.)
| | - Yasin Temel
- Department of Experimental Neurosurgery, Maastricht University Medical Center, 6202 AZ Maastricht, The Netherlands;
| | - Pierre-Louis Bazin
- Integrative Model-based Cognitive Neuroscience Research Unit, University of Amsterdam, 1018 WS Amsterdam, The Netherlands; (A.A.); (P.-L.B.); (B.U.F.)
- Max Planck Institute for Human Cognitive and Brain Sciences, D-04103 Leipzig, Germany
| | - Birte U. Forstmann
- Integrative Model-based Cognitive Neuroscience Research Unit, University of Amsterdam, 1018 WS Amsterdam, The Netherlands; (A.A.); (P.-L.B.); (B.U.F.)
| |
Collapse
|
12
|
Polanski WH, Zolal A, Sitoci-Ficici KH, Hiepe P, Schackert G, Sobottka SB. Comparison of Automatic Segmentation Algorithms for the Subthalamic Nucleus. Stereotact Funct Neurosurg 2020; 98:256-262. [PMID: 32369819 DOI: 10.1159/000507028] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2019] [Accepted: 02/13/2020] [Indexed: 12/30/2022]
Abstract
INTRODUCTION Various automatic segmentation algorithms for the subthalamic nucleus (STN) have been published recently. However, most of the available software tools are not approved for clinical use. OBJECTIVE The aim of this study is to evaluate a clinically available automatic segmentation tool of the navigation planning software Brainlab Elements (BL-E) by comparing the output to manual segmentation and a nonclinically approved research method using the DISTAL atlas (DA) and the Horn electrophysiological atlas (HEA). METHODS Preoperative MRI data of 30 patients with idiopathic Parkinson's disease were used, resulting in 60 STN segmentations. The segmentations were created manually by two clinical experts. Automatic segmentations of the STN were obtained from BL-E and Advanced Normalization Tools using DA and HEA. Differences between manual and automatic segmentations were quantified by Dice and Jaccard coefficient, target overlap, and false negative/positive value (FNV/FPV) measurements. Statistical differences between similarity measures were assessed using the Wilcoxon signed-rank test with continuity correction, and comparison with interrater results was performed using the Mann-Whitney U test. RESULTS For manual segmentation, the mean size of the segmented STN was 133 ± 24 mm3. The mean size of the STN was 121 ± 18 mm3 for BL-E, 162 ± 21 mm3 for DA, and 130 ± 17 mm3 for HEA. The Dice coefficient for the interrater comparison was 0.63 and 0.54 ± 0.12, 0.59 ± 0.13, and 0.52 ± 0.14 for BL-E, DA, and HEA, respectively. Significant differences between similarity measures were found for Dice and Jaccard coefficient, target overlap and FNV between BL-E and DA; and FPV between BL-E and HEA. However, none of the differences were significant compared to interrater variability. The analysis of the center of gravity of the segmentations revealed that the BL-E STN ROI was located more medially, superior and posterior compared to other segmentations. Regarding the target overlap for beta power within the STN ROI included with the HEA, the BL-E segmentation showed a significantly higher value compared to manual segmentation. CONCLUSION Automatic image segmentation by means of the clinically approved software BL-E provides STN segmentations with similar accuracy like research tools, and differences are in the range of observed interrater variability. Further studies are required to investigate the clinical validity, for example, by comparing segmentation results of BL-E with electrophysiological data.
Collapse
Affiliation(s)
- Witold H Polanski
- Department of Neurosurgery, University Hospital Carl-Gustav-Carus, Technical University of Dresden, Dresden, Germany,
| | - Amir Zolal
- Department of Neurosurgery, University Hospital Carl-Gustav-Carus, Technical University of Dresden, Dresden, Germany.,Department of Spine Surgery and Neurotraumatology, SRH Wald-Klinikum Gera, Gera, Germany
| | - Kerim Hakan Sitoci-Ficici
- Department of Neurosurgery, University Hospital Carl-Gustav-Carus, Technical University of Dresden, Dresden, Germany
| | | | - Gabriele Schackert
- Department of Neurosurgery, University Hospital Carl-Gustav-Carus, Technical University of Dresden, Dresden, Germany
| | - Stephan B Sobottka
- Department of Neurosurgery, University Hospital Carl-Gustav-Carus, Technical University of Dresden, Dresden, Germany
| |
Collapse
|
13
|
Park SC, Cha JH, Lee S, Jang W, Lee CS, Lee JK. Deep Learning-Based Deep Brain Stimulation Targeting and Clinical Applications. Front Neurosci 2019; 13:1128. [PMID: 31708729 PMCID: PMC6821714 DOI: 10.3389/fnins.2019.01128] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2019] [Accepted: 10/04/2019] [Indexed: 12/26/2022] Open
Abstract
Background The purpose of the present study was to evaluate deep learning-based image-guided surgical planning for deep brain stimulation (DBS). We developed deep learning semantic segmentation-based DBS targeting and prospectively applied the method clinically. Methods T2∗ fast gradient-echo images from 102 patients were used for training and validation. Manually drawn ground truth information was prepared for the subthalamic and red nuclei with an axial cut ∼4 mm below the anterior–posterior commissure line. A fully convolutional neural network (FCN-VGG-16) was used to ensure margin identification by semantic segmentation. Image contrast augmentation was performed nine times. Up to 102 original images and 918 augmented images were used for training and validation. The accuracy of semantic segmentation was measured in terms of mean accuracy and mean intersection over the union. Targets were calculated based on their relative distance from these segmented anatomical structures considering the Bejjani target. Results Mean accuracies and mean intersection over the union values were high: 0.904 and 0.813, respectively, for the 62 training images, and 0.911 and 0.821, respectively, for the 558 augmented training images when 360 augmented validation images were used. The Dice coefficient converted from the intersection over the union was 0.902 when 720 training and 198 validation images were used. Semantic segmentation was adaptive to high anatomical variations in size, shape, and asymmetry. For clinical application, two patients were assessed: one with essential tremor and another with bradykinesia and gait disturbance due to Parkinson’s disease. Both improved without complications after surgery, and microelectrode recordings showed subthalamic nuclei signals in the latter patient. Conclusion The accuracy of deep learning-based semantic segmentation may surpass that of previous methods. DBS targeting and its clinical application were made possible using accurate deep learning-based semantic segmentation, which is adaptive to anatomical variations.
Collapse
Affiliation(s)
- Seong-Cheol Park
- Department of Neurosurgery, Seoul Metropolitan Government - Seoul National University Boramae Medical Center, Seoul, South Korea.,Department of Neurosurgery, Gangneung Asan Hospital, University of Ulsan, Gangneung, South Korea
| | - Joon Hyuk Cha
- Department of Neurosurgery, Seoul Metropolitan Government - Seoul National University Boramae Medical Center, Seoul, South Korea.,School of Medicine, Inha University, Incheon, South Korea
| | - Seonhwa Lee
- Department of Neurosurgery, Seoul Metropolitan Government - Seoul National University Boramae Medical Center, Seoul, South Korea.,Department of Bio-Convergence Engineering, College of Health Science, Korea University, Seoul, South Korea
| | - Wooyoung Jang
- Department of Neurology, Gangneung Asan Hospital, University of Ulsan, Gangneung, South Korea
| | - Chong Sik Lee
- Department of Neurology, Asan Medical Center, University of Ulsan, Seoul, South Korea
| | - Jung Kyo Lee
- Department of Neurosurgery, Asan Medical Center, University of Ulsan, Seoul, South Korea
| |
Collapse
|
14
|
Dimov AV, Gupta A, Kopell BH, Wang Y. High-resolution QSM for functional and structural depiction of subthalamic nuclei in DBS presurgical mapping. J Neurosurg 2019; 131:360-367. [PMID: 30095333 DOI: 10.3171/2018.3.jns172145] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2017] [Accepted: 03/01/2018] [Indexed: 11/06/2022]
Abstract
OBJECTIVE Faithful depiction of the subthalamic nucleus (STN) is critical for planning deep brain stimulation (DBS) surgery in patients with Parkinson's disease (PD). Quantitative susceptibility mapping (QSM) has been shown to be superior to traditional T2-weighted spin echo imaging (T2w). The aim of the study was to describe submillimeter QSM for preoperative imaging of the STN in planning of DBS. METHODS Seven healthy volunteers were included in this study. T2w and QSM were obtained for all healthy volunteers, and images of different resolutions were reconstructed. Image quality and visibility of STN anatomical features were analyzed by a radiologist using a 5-point scale, and contrast properties of the STN and surrounding tissue were calculated. Additionally, data from 10 retrospectively and randomly selected PD patients who underwent 3-T MRI for DBS were analyzed for STN size and susceptibility gradient measurements. RESULTS Higher contrast-to-noise ratio (CNR) values were observed in both high-resolution and low-resolution QSM images. Inter-resolution comparison demonstrated improvement in CNR for QSM, but not for T2w images. QSM provided higher inter-quadrant contrast ratios (CR) within the STN, and depicted a gradient in the distribution of susceptibility sources not visible in T2w images. CONCLUSIONS For 3-T MRI, submillimeter QSM provides accurate delineation of the functional and anatomical STN features for DBS targeting.
Collapse
Affiliation(s)
- Alexey V Dimov
- 1Meinig School of Biomedical Engineering, Cornell University, Ithaca
- 2Department of Radiology, Weill Medical College of Cornell University; and
| | - Ajay Gupta
- 2Department of Radiology, Weill Medical College of Cornell University; and
| | - Brian H Kopell
- 3Department of Neurosurgery, Mount Sinai Health System, New York, New York
| | - Yi Wang
- 1Meinig School of Biomedical Engineering, Cornell University, Ithaca
- 2Department of Radiology, Weill Medical College of Cornell University; and
| |
Collapse
|
15
|
Rashid T, Hwang R, DiMarzio M, Hancu I, Pilitsis JG. Evaluating the role of 1.5T quantitative susceptibility mapping for subthalamic nucleus targeting in deep brain stimulation surgery. J Neuroradiol 2019; 48:37-42. [PMID: 31150663 DOI: 10.1016/j.neurad.2019.04.007] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2018] [Revised: 03/29/2019] [Accepted: 04/23/2019] [Indexed: 11/17/2022]
Abstract
BACKGROUND AND PURPOSE Quantitative susceptibility mapping (QSM) has been shown to be valuable in direct targeting for subthalamic nucleus (STN) DBS, given its higher quality of contrast between the STN border and adjacent anatomical structures. The objective is to demonstrate the feasibility of using 1.5T QSM for direct targeting in STN DBS planning. MATERIAL AND METHODS Eleven patients underwent MRI acquisitions using a 1.5T scanner, including multi-echo gradient echo sequences for generating QSM images. 22 STN targets were planned with direct targeting method using QSM images by one stereotactic neurosurgeon and indirect targeting method using standard protocol by a second stereotactic neurosurgeon. The two physicians were blinded to each other's results. RESULTS The mean coordinates for the STN using direct targeting relative to the mid-commissural point (MCP) was 11.41±2.43mm lateral, 2.48±0.53mm posterior and 4.45±0.95mm inferior. The mean coordinates for the STN using indirect targeting was 11.79±2.51mm lateral, 2.55±0.54mm posterior, and 4.84±1.03mm inferior. The mean (±SEM) radial error between the direct and indirect target was 0.67±0.14mm. In cases where DBS electrodes were implanted, the radial difference between the indirect and actual target (1.19±0.30mm) was statistically equivalent to the radial difference between the direct and actual target (1.0±0.27mm). CONCLUSIONS Direct targeting of the STN for DBS implantation using 1.5T QSM was found to be statistically equivalent to standard protocol surgery planning. This may offer a simpler, more intuitive alternative for DBS surgery planning at centers with 1.5T MRIs.
Collapse
Affiliation(s)
- Tanweer Rashid
- Department of Neuroscience and Experimental Therapeutics, Albany Medical College, Albany, NY, USA
| | - Roy Hwang
- Department of Neurosurgery, Albany Medical Center, Albany, NY, USA
| | - Marisa DiMarzio
- Department of Neuroscience and Experimental Therapeutics, Albany Medical College, Albany, NY, USA
| | | | - Julie G Pilitsis
- Department of Neuroscience and Experimental Therapeutics, Albany Medical College, Albany, NY, USA; Department of Neurosurgery, Albany Medical Center, Albany, NY, USA.
| |
Collapse
|
16
|
Reconfigurable MRI technology for low-SAR imaging of deep brain stimulation at 3T: Application in bilateral leads, fully-implanted systems, and surgically modified lead trajectories. Neuroimage 2019; 199:18-29. [PMID: 31096058 DOI: 10.1016/j.neuroimage.2019.05.015] [Citation(s) in RCA: 40] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2019] [Revised: 04/24/2019] [Accepted: 05/06/2019] [Indexed: 11/22/2022] Open
Abstract
Patients with deep brain stimulation devices highly benefit from postoperative MRI exams, however MRI is not readily accessible to these patients due to safety risks associated with RF heating of the implants. Recently we introduced a patient-adjustable reconfigurable coil technology that substantially reduced local SAR at tips of single isolated DBS leads during MRI at 1.5 T in 9 realistic patient models. This contribution extends our work to higher fields by demonstrating the feasibility of scaling the technology to 3T and assessing its performance in patients with bilateral leads as well as fully implanted systems. We developed patient-derived models of bilateral DBS leads and fully implanted DBS systems from postoperative CT images of 13 patients and performed finite element simulations to calculate SAR amplification at electrode contacts during MRI with a reconfigurable rotating coil at 3T. Compared to a conventional quadrature body coil, the reconfigurable coil system reduced the SAR on average by 83% for unilateral leads and by 59% for bilateral leads. A simple surgical modification in trajectory of implanted leads was demonstrated to increase the SAR reduction efficiency of the rotating coil to >90% in a patient with a fully implanted bilateral DBS system. Thermal analysis of temperature-rise around electrode contacts during typical brain exams showed a 15-fold heating reduction using the rotating coil, generating <1°C temperature rise during ∼4-min imaging with high-SAR sequences where a conventional CP coil generated >10°C temperature rise in the tissue for the same flip angle.
Collapse
|
17
|
Mulder MJ, Keuken MC, Bazin PL, Alkemade A, Forstmann BU. Size and shape matter: The impact of voxel geometry on the identification of small nuclei. PLoS One 2019; 14:e0215382. [PMID: 30978242 PMCID: PMC6461289 DOI: 10.1371/journal.pone.0215382] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2018] [Accepted: 04/01/2019] [Indexed: 12/28/2022] Open
Abstract
How, and to what extent do size and shape of a voxel measured with magnetic resonance imaging (MRI) affect the ability to visualize small brain nuclei? Despite general consensus that voxel geometry affects volumetric properties of regions of interest, particularly those of small brain nuclei, no quantitative data on the influence of voxel size and shape on labeling accuracy is available. Using simulations, we investigated the selective influence of voxel geometry by reconstructing simulated ellipsoid structures with voxels varying in shape and size. For each reconstructed ellipsoid, we calculated differences in volume and similarity between the labeled volume and the predefined dimensions of the ellipsoid. Probability functions were derived from one or two individual raters and a simulated ground truth for reference. As expected, larger voxels (i.e., coarser resolution) and increasing anisotropy results in increased deviations of both volume and shape measures, which is of particular relevance for small brain structures. Our findings clearly illustrate the anatomical inaccuracies introduced by the application of large and/or anisotropic voxels. To ensure deviations occur within the acceptable range (Dice coefficient scores; DCS > 0.75, corresponding to < 57% volume deviation), the volume of isotropic voxels should not exceed 5% of the total volume of the region of interest. When high accuracy is required (DCS > 0.90, corresponding to a < 19% volume deviation), the volumes of isotropic voxels should not exceed 0.08%, of the total volume. Finally, when large anisotropic factors (>3) are used, and the ellipsoid is orthogonal to the slice axes, having its long axis in the imaging plane, the voxel volume should not exceed 0.005% of the total volume. This allows sufficient compensation of anisotropy effects, in order to reach accuracy in the acceptable range (DCS > 0.75, corresponding to >57% volume deviation).
Collapse
Affiliation(s)
- Martijn J Mulder
- Integrative Model-Based Cognitive Neuroscience Research Unit, University of Amsterdam, Amsterdam, The Netherlands.,Experimental Psychology, Utrecht University, Utrecht, the Netherlands
| | - Max C Keuken
- Integrative Model-Based Cognitive Neuroscience Research Unit, University of Amsterdam, Amsterdam, The Netherlands
| | - Pierre-Louis Bazin
- Integrative Model-Based Cognitive Neuroscience Research Unit, University of Amsterdam, Amsterdam, The Netherlands.,Department of Neurology, Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany
| | - Anneke Alkemade
- Integrative Model-Based Cognitive Neuroscience Research Unit, University of Amsterdam, Amsterdam, The Netherlands
| | - Birte U Forstmann
- Integrative Model-Based Cognitive Neuroscience Research Unit, University of Amsterdam, Amsterdam, The Netherlands
| |
Collapse
|
18
|
Muthuraman M, Koirala N, Ciolac D, Pintea B, Glaser M, Groppa S, Tamás G, Groppa S. Deep Brain Stimulation and L-DOPA Therapy: Concepts of Action and Clinical Applications in Parkinson's Disease. Front Neurol 2018; 9:711. [PMID: 30210436 PMCID: PMC6119713 DOI: 10.3389/fneur.2018.00711] [Citation(s) in RCA: 49] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2018] [Accepted: 08/06/2018] [Indexed: 12/15/2022] Open
Abstract
L-DOPA is still the most effective pharmacological therapy for the treatment of motor symptoms in Parkinson's disease (PD) almost four decades after it was first used. Deep brain stimulation (DBS) is a safe and highly effective treatment option in patients with PD. Even though a clear understanding of the mechanisms of both treatment methods is yet to be obtained, the combination of both treatments is the most effective standard evidenced-based therapy to date. Recent studies have demonstrated that DBS is a therapy option even in the early course of the disease, when first complications arise despite a rigorous adjustment of the pharmacological treatment. The unique feature of this therapeutic approach is the ability to preferentially modulate specific brain networks through the choice of stimulation site. The clinical effects have been unequivocally confirmed in recent studies; however, the impact of DBS and the supplementary effect of L-DOPA on the neuronal network are not yet fully understood. In this review, we present emerging data on the presumable mechanisms of DBS in patients with PD and discuss the pathophysiological similarities and differences in the effects of DBS in comparison to dopaminergic medication. Targeted, selective modulation of brain networks by DBS and pharmacodynamic effects of L-DOPA therapy on the central nervous system are presented. Moreover, we outline the perioperative algorithms for PD patients before and directly after the implantation of DBS electrodes and strategies for the reduction of side effects and optimization of motor and non-motor symptoms.
Collapse
Affiliation(s)
- Muthuraman Muthuraman
- Movement Disorders and Neurostimulation, Biomedical Statistics and Multimodal Signal Processing Unit, Department of Neurology, University Medical Center of the Johannes Gutenberg University, Mainz, Germany
| | - Nabin Koirala
- Movement Disorders and Neurostimulation, Biomedical Statistics and Multimodal Signal Processing Unit, Department of Neurology, University Medical Center of the Johannes Gutenberg University, Mainz, Germany
| | - Dumitru Ciolac
- Department of Neurology, Institute of Emergency Medicine, Chisinau, Moldova.,Laboratory of Neurobiology and Medical Genetics, Nicolae Testemiţanu State University of Medicine and Pharmacy, Chisinau, Moldova
| | - Bogdan Pintea
- Department of Neurosurgery, University Hospital of Bonn, Bonn, Germany
| | - Martin Glaser
- Department of Neurosurgery, University Medical Center of the Johannes Gutenberg University, Mainz, Germany
| | - Stanislav Groppa
- Department of Neurology, Institute of Emergency Medicine, Chisinau, Moldova.,Laboratory of Neurobiology and Medical Genetics, Nicolae Testemiţanu State University of Medicine and Pharmacy, Chisinau, Moldova
| | - Gertrúd Tamás
- Department of Neurology, Semmelweis University, Budapest, Hungary
| | - Sergiu Groppa
- Movement Disorders and Neurostimulation, Biomedical Statistics and Multimodal Signal Processing Unit, Department of Neurology, University Medical Center of the Johannes Gutenberg University, Mainz, Germany
| |
Collapse
|
19
|
|
20
|
|
21
|
Saleh C, Dooms G, Berthold C, Hertel F. Post-operative imaging in deep brain stimulation: A controversial issue. Neuroradiol J 2016; 29:244-9. [PMID: 27029393 PMCID: PMC4978322 DOI: 10.1177/1971400916639960] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
Abstract
In deep brain stimulation (DBS), post-operative imaging has been used on the one hand to assess complications, such as haemorrhage; and on the other hand, to detect misplaced contacts. The post-operative determination of the accurate location of the final electrode plays a critical role in evaluating the precise area of effective stimulation and for predicting the potential clinical outcome; however, safety remains a priority in postoperative DBS imaging. A plethora of diverse post-operative imaging methods have been applied at different centres. There is neither a consensus on the most efficient post-operative imaging methodology, nor is there any standardisation for the automatic or manual analysis of the images within the different imaging modalities. In this article, we give an overview of currently applied post-operative imaging modalities and discuss the current challenges in post-operative imaging in DBS.
Collapse
Affiliation(s)
- Christian Saleh
- Department of Neurology, Centre Hospitalier de Luxembourg, Luxembourg
| | - Georges Dooms
- Department of Neuroradiology, Centre Hospitalier de Luxembourg, Luxembourg
| | | | - Frank Hertel
- Department of Neurosurgery, Centre Hospitalier de Luxembourg, Luxembourg
| |
Collapse
|
22
|
Wu ML, Chang HC, Chao TC, Chen NK. Efficient imaging of midbrain nuclei using inverse double-echo steady-state acquisition. Med Phys 2016; 42:4367-74. [PMID: 26133633 DOI: 10.1118/1.4922402] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
PURPOSE Imaging of midbrain nuclei using T2- or T2*-weighted MRI often entails long echo time, leading to long scan time. In this study, an inverse double-echo steady-state (iDESS) technique is proposed for efficiently depicting midbrain nuclei. METHODS Thirteen healthy subjects participated in this study. iDESS was performed along with two sets of T2*-weighted spoiled gradient-echo images (SPGR1, with scan time identical to iDESS and SPGR2, using clinical scanning parameters as a reference standard) for comparison. Generation of iDESS composite images combining two echo signals was optimized for maximal contrast-to-noise ratio (CNR) between the red nuclei and surrounding tissues. Signal-to-noise ratios (SNRs) were calculated from the occipital lobe. Comparison was also made using phase-enhanced images as in standard susceptibility-weighted imaging (SWI). RESULTS The iDESS images present significantly higher SNR efficiency (171.3) than SPGR1 (158.7, p = 0.013) and SPGR2 (95.5, p < 10(-8)). iDESS CNR efficiency (19.2) is also significantly greater than SPGR1 (6.9, p < 10(-6)) and SPGR2 (14.3, p = 0.0016). Compared with DESS, iDESS provides further advantage on enhanced phase information and hence improved contrast on SWI-processed images. CONCLUSIONS iDESS efficiently depicts midbrain nuclei with improved CNR efficiency, increased SNR efficiency, and reduced scan time and is less prone to susceptibility signal loss from air-tissue interfaces.
Collapse
Affiliation(s)
- Ming-Long Wu
- Department of Computer Science and Information Engineering, National Cheng Kung University, No. 1, University Road, Tainan 70101, Taiwan and Institute of Medical Informatics, National Cheng Kung University, No. 1, University Road, Tainan 70101, Taiwan
| | - Hing-Chiu Chang
- Brain Imaging and Analysis Center, Duke University Medical Center, 2424 Erwin Road, Suite 501, Durham, North Carolina 27705 and Department of Diagnostic Radiology, The University of Hong Kong, Room 406, Block K, Queen Mary Hospital, Pok Fu Lam Road, Hong Kong
| | - Tzu-Cheng Chao
- Department of Computer Science and Information Engineering, National Cheng Kung University, No. 1, University Road, Tainan 70101, Taiwan and Institute of Medical Informatics, National Cheng Kung University, No. 1, University Road, Tainan 70101, Taiwan
| | - Nan-Kuei Chen
- Brain Imaging and Analysis Center, Duke University Medical Center, 2424 Erwin Road, Suite 501, Durham, North Carolina 27705
| |
Collapse
|
23
|
Chandran AS, Bynevelt M, Lind CRP. Magnetic resonance imaging of the subthalamic nucleus for deep brain stimulation. J Neurosurg 2016; 124:96-105. [DOI: 10.3171/2015.1.jns142066] [Citation(s) in RCA: 52] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
The subthalamic nucleus (STN) is one of the most important stereotactic targets in neurosurgery, and its accurate imaging is crucial. With improving MRI sequences there is impetus for direct targeting of the STN. High-quality, distortion-free images are paramount. Image reconstruction techniques appear to show the greatest promise in balancing the issue of geometrical distortion and STN edge detection. Existing spin echo- and susceptibility-based MRI sequences are compared with new image reconstruction methods. Quantitative susceptibility mapping is the most promising technique for stereotactic imaging of the STN.
Collapse
Affiliation(s)
| | - Michael Bynevelt
- 2Radiology, Sir Charles Gairdner Hospital, and
- 3School of Surgery, University of Western Australia, Perth, Western Australia, Australia
| | - Christopher R. P. Lind
- Departments of 1Neurosurgery and
- 3School of Surgery, University of Western Australia, Perth, Western Australia, Australia
| |
Collapse
|
24
|
Kocabicak E, Alptekin O, Ackermans L, Kubben P, Kuijf M, Kurt E, Esselink R, Temel Y. Is there still need for microelectrode recording now the subthalamic nucleus can be well visualized with high field and ultrahigh MR imaging? Front Integr Neurosci 2015; 9:46. [PMID: 26321929 PMCID: PMC4531226 DOI: 10.3389/fnint.2015.00046] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2015] [Accepted: 07/15/2015] [Indexed: 12/16/2022] Open
Affiliation(s)
- Ersoy Kocabicak
- Department of Neurosurgery, Maastricht Medical Center Maastricht, Netherlands ; Department of Neuroscience, Maastricht University Medical Center Maastricht, Netherlands ; Department of Neurosurgery, Ondokuz Mayis University Samsun, Turkey
| | - Onur Alptekin
- Department of Neuroscience, Maastricht University Medical Center Maastricht, Netherlands
| | - Linda Ackermans
- Department of Neurosurgery, Maastricht Medical Center Maastricht, Netherlands
| | - Pieter Kubben
- Department of Neurosurgery, Maastricht Medical Center Maastricht, Netherlands
| | - Mark Kuijf
- Department of Neurology, Maastricht Medical Center Maastricht, Netherlands
| | - Erkan Kurt
- Department of Neurosurgery, Donders Institute for Cognition, Brain and Behaviour, Radboud University Medical Center Nijmegen, Netherlands
| | - Rianne Esselink
- Department of Neurology, Donders Institute for Cognition, Brain and Behaviour, Radboud University Medical Center Nijmegen, Netherlands
| | - Yasin Temel
- Department of Neurosurgery, Maastricht Medical Center Maastricht, Netherlands ; Department of Neuroscience, Maastricht University Medical Center Maastricht, Netherlands
| |
Collapse
|
25
|
Heo YJ, Kim SJ, Kim HS, Choi CG, Jung SC, Lee JK, Lee CS, Chung SJ, Cho SH, Lee GR. Three-dimensional fluid-attenuated inversion recovery sequence for visualisation of subthalamic nucleus for deep brain stimulation in Parkinson's disease. Neuroradiology 2015; 57:929-35. [PMID: 26156865 DOI: 10.1007/s00234-015-1555-z] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2015] [Accepted: 06/24/2015] [Indexed: 02/06/2023]
Abstract
INTRODUCTION Deep brain stimulation (DBS) of the subthalamic nucleus (STN) is an accepted treatment for advanced Parkinson's disease (PD). However, targeting the STN is difficult due to its relatively small size and variable location. The purpose of this study was to assess which of the following sequences obtained with the 3.0 T MR system can accurately delineate the STN: coronal 3D fluid-attenuated inversion recovery (FLAIR), 2D T2*-weighted fast-field echo (T2*-FFE) and 2D T2-weighted turbo spin-echo (TSE) sequences. METHODS We included 20 consecutive patients with PD who underwent 3.0 T MR for DBS targeting. 3D FLAIR, 2D T2*-FFE and T2-TSE images were obtained for all study patients. Image quality and demarcation of the STN were analysed using 4-point scales, and contrast ratio (CR) of the STN and normal white matter was calculated. The Friedman test was used to compare the three sequences. RESULTS In qualitative analysis, the 2D T2*-FFE image showed more artefacts than 3D FLAIR or 2D T2-TSE, but the difference did not reach statistical significance. 3D FLAIR images showed significantly superior demarcation of the STN compared with 2D T2*-FFE and T2-TSE images (P < 0.001, respectively). The CR of 3D FLAIR was significantly higher than that of 2D T2*-FFE or T2-TSE images in multiple comparison correction (P < 0.001), but there was no significant difference in the CR between 2D T2*-FFE and T2-TSE images. CONCLUSION Coronal 3D FLAIR images showed the most accurate demarcation of the STN for DBS targeting among coronal 3D FLAIR, 2D T2*-FFE and T2-TSE images.
Collapse
Affiliation(s)
- Young Jin Heo
- Department of Radiology, Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, 138-736, Korea
- Department of Radiology, Busan Paik Hospital, Inje University, Busan, Korea
| | - Sang Joon Kim
- Department of Radiology, Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, 138-736, Korea.
| | - Ho Sung Kim
- Department of Radiology, Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, 138-736, Korea
| | - Choong Gon Choi
- Department of Radiology, Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, 138-736, Korea
| | - Seung Chai Jung
- Department of Radiology, Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, 138-736, Korea
| | - Jung Kyo Lee
- Department of Neurosurgery, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Korea
| | - Chong Sik Lee
- Department of Neurology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Korea
| | - Sun J Chung
- Department of Neurology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Korea
| | - So Hyun Cho
- Department of Radiology, Sebarun Hospital, Busan, Korea
| | | |
Collapse
|
26
|
Polanski WH, Martin KD, Engellandt K, von Kummer R, Klingelhoefer L, Fauser M, Storch A, Schackert G, Sobottka SB. Accuracy of subthalamic nucleus targeting by T2, FLAIR and SWI-3-Tesla MRI confirmed by microelectrode recordings. Acta Neurochir (Wien) 2015; 157:479-86. [PMID: 25596640 DOI: 10.1007/s00701-014-2328-x] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2014] [Accepted: 12/22/2014] [Indexed: 10/24/2022]
Abstract
BACKGROUND Successful deep brain stimulation is mostly dependent on accurate positioning of the leads at the optimal target points. We investigated whether the identification of the subthalamic nucleus in T2-weighted 3-T MRI, fluid-attenuated inversion recovery 3-T MRI and susceptibility-weighted 3-T MRI is confirmed by intraoperative neurological microelectrode recording. METHODS We evaluated 182 microelectrode recording leads in 21 patients with bilateral deep brain stimulation, retrospectively. Consequently, 728 electrode contact positions in T2-weighted 3-T MRI, 552 electrode contact positions in fluid-attenuated inversion recovery 3-T MRI and 490 electrode contact positions in susceptibility-weighted 3-T MRI were evaluated for a positive nucleus subthalamicus signal. RESULTS The highest sensitivity was measured for fluid-attenuated inversion recovery 3-T MRI with 82.5 %, while the highest specificity was observed for susceptibility-weighted 3-T MRI with 90.6 %. The negative predictive value was nearly equal for susceptibility-weighted MRI and fluid-attenuated inversion recovery MRI with 87.5 % vs. 87.1 %, but the positive predictive value was higher in susceptibility-weighted 3-T MRI (86.0 %) than in the other MRI sequences. CONCLUSIONS The susceptibility-weighted 3-T MRI-based subthalamic nucleus localization shows the best accuracy compared with T2-weighted and fluid-attenuated inversion recovery 3-T MRI. Therefore, the susceptibility-weighted 3-T MRI should be preferred for surgical planning when the operation procedure is performed under general anesthesia without microelectrode recordings.
Collapse
|
27
|
Wang Y, Liu T. Quantitative susceptibility mapping (QSM): Decoding MRI data for a tissue magnetic biomarker. Magn Reson Med 2015; 73:82-101. [PMID: 25044035 PMCID: PMC4297605 DOI: 10.1002/mrm.25358] [Citation(s) in RCA: 622] [Impact Index Per Article: 62.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2014] [Revised: 06/13/2014] [Accepted: 06/18/2014] [Indexed: 01/03/2023]
Abstract
In MRI, the main magnetic field polarizes the electron cloud of a molecule, generating a chemical shift for observer protons within the molecule and a magnetic susceptibility inhomogeneity field for observer protons outside the molecule. The number of water protons surrounding a molecule for detecting its magnetic susceptibility is vastly greater than the number of protons within the molecule for detecting its chemical shift. However, the study of tissue magnetic susceptibility has been hindered by poor molecular specificities of hitherto used methods based on MRI signal phase and T2* contrast, which depend convolutedly on surrounding susceptibility sources. Deconvolution of the MRI signal phase can determine tissue susceptibility but is challenged by the lack of MRI signal in the background and by the zeroes in the dipole kernel. Recently, physically meaningful regularizations, including the Bayesian approach, have been developed to enable accurate quantitative susceptibility mapping (QSM) for studying iron distribution, metabolic oxygen consumption, blood degradation, calcification, demyelination, and other pathophysiological susceptibility changes, as well as contrast agent biodistribution in MRI. This paper attempts to summarize the basic physical concepts and essential algorithmic steps in QSM, to describe clinical and technical issues under active development, and to provide references, codes, and testing data for readers interested in QSM.
Collapse
Affiliation(s)
- Yi Wang
- Radiology, Weill Medical College of Cornell UniversityNew York, New York, USA
- Biomedical Engineering, Cornell UniversityIthaca, New York, USA
- Biomedical Engineering, Kyung Hee UniversitySeoul, South Korea
| | - Tian Liu
- MedImageMetric, LLCNew York, New York, USA
| |
Collapse
|
28
|
Plantinga BR, Temel Y, Roebroeck A, Uludağ K, Ivanov D, Kuijf ML, Ter Haar Romenij BM. Ultra-high field magnetic resonance imaging of the basal ganglia and related structures. Front Hum Neurosci 2014; 8:876. [PMID: 25414656 PMCID: PMC4220687 DOI: 10.3389/fnhum.2014.00876] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2014] [Accepted: 10/10/2014] [Indexed: 12/13/2022] Open
Abstract
Deep brain stimulation is a treatment for Parkinson's disease and other related disorders, involving the surgical placement of electrodes in the deeply situated basal ganglia or thalamic structures. Good clinical outcome requires accurate targeting. However, due to limited visibility of the target structures on routine clinical MR images, direct targeting of structures can be challenging. Non-clinical MR scanners with ultra-high magnetic field (7T or higher) have the potential to improve the quality of these images. This technology report provides an overview of the current possibilities of visualizing deep brain stimulation targets and their related structures with the aid of ultra-high field MRI. Reviewed studies showed improved resolution, contrast- and signal-to-noise ratios at ultra-high field. Sequences sensitive to magnetic susceptibility such as T2* and susceptibility weighted imaging and their maps in general showed the best visualization of target structures, including a separation between the subthalamic nucleus and the substantia nigra, the lamina pallidi medialis and lamina pallidi incompleta within the globus pallidus and substructures of the thalamus, including the ventral intermediate nucleus (Vim). This shows that the visibility, identification, and even subdivision of the small deep brain stimulation targets benefit from increased field strength. Although ultra-high field MR imaging is associated with increased risk of geometrical distortions, it has been shown that these distortions can be avoided or corrected to the extent where the effects are limited. The availability of ultra-high field MR scanners for humans seems to provide opportunities for a more accurate targeting for deep brain stimulation in patients with Parkinson's disease and related disorders.
Collapse
Affiliation(s)
- Birgit R Plantinga
- Biomedical Image Analysis, Eindhoven University of Technology Eindhoven, Netherlands ; Department of Neuroscience, Maastricht University Maastricht, Netherlands
| | - Yasin Temel
- Department of Neuroscience, Maastricht University Maastricht, Netherlands ; Department of Neurology, Maastricht University Medical Center Maastricht, Netherlands
| | - Alard Roebroeck
- Department of Neurosurgery, Maastricht University Medical Center Maastricht, Netherlands
| | - Kâmil Uludağ
- Department of Neurosurgery, Maastricht University Medical Center Maastricht, Netherlands
| | - Dimo Ivanov
- Department of Neurosurgery, Maastricht University Medical Center Maastricht, Netherlands
| | - Mark L Kuijf
- Department of Cognitive Neuroscience, Maastricht University Maastricht, Netherlands
| | - Bart M Ter Haar Romenij
- Biomedical Image Analysis, Eindhoven University of Technology Eindhoven, Netherlands ; Department of Biomedical and Information Engineering, Northeastern University Shenyang, China
| |
Collapse
|
29
|
Lefranc M, Derrey S, Merle P, Tir M, Constans JM, Montpellier D, Macron JM, Le Gars D, Peltier J, Baledentt O, Krystkowiak P. High-Resolution 3-Dimensional T2*-Weighted Angiography (HR 3-D SWAN). Neurosurgery 2014; 74:615-26; discussion 627. [DOI: 10.1227/neu.0000000000000319] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
ABSTRACT
BACKGROUND:
Subthalamic nucleus deep brain stimulation (STN-DBS) is an established treatment for Parkinson's disease.
OBJECTIVE:
To characterize an optimized magnetic resonance imaging (MRI) sequence (high-resolution 3-dimensional T2*-weighted angiography [HR 3-D SWAN]) for direct STN targeting.
METHODS:
Sequence distortions were measured using the Leksell stereotactic phantom. Eight consecutive candidates for STN-DBS underwent HR 3-D SWAN MRI for direct identification of the 16 STN. Two senior neurosurgeons independently determined the boundaries of STN on a semiquantitative scale (ranging from 1 [identification very easy] to 4 [identification very difficult]) and the anatomic target within the nucleus. The anatomic data were compared with electrophysiological recordings (48 microrecordings). We examined the anatomic location of the active contacts on MRI.
RESULTS:
The mean distortion error over the phantom was 0.16 mm. For the 16 STNs, identification of the upper, internal, anterior, and external edges was considered to be easy (scores of 1 or 2). The distinction between the substantia nigra and the STN was rated 1 or 2 for all but 6 nuclei. In the mediolateral axis, electrophysiological recordings covered perfectly anatomic data. In the craniocaudal axis, the mean differences between the electrophysiological data and the anatomic data were 0.8 mm and 0.19 mm for the “entry” and “exit” of the STN, respectively. All active contacts were located within the STN on MRI.
CONCLUSION:
HR 3-D SWAN allows easy visualization of the STN. Adapted to stereotactic requirement, the sequence simplifies direct targeting in STN-DBS surgery.
Collapse
Affiliation(s)
| | - Stéphane Derrey
- Department of Neurosurgery, Rouen University Medical Center, Rouen, France
| | | | | | | | | | | | | | | | | | | |
Collapse
|
30
|
Camlidag I, Kocabicak E, Sahin B, Jahanshahi A, Incesu L, Aygun D, Yildiz O, Temel Y, Belet U. Volumetric analysis of the subthalamic and red nuclei based on magnetic resonance imaging in patients with Parkinson's disease. Int J Neurosci 2013; 124:291-5. [PMID: 24020352 DOI: 10.3109/00207454.2013.843091] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Parkinson's disease (PD) is associated with degeneration of the dopaminergic neurons in the substantia nigra. The subthalamic nucleus (STN) plays a pivotal role in the pathogenesis. However, there is not much known about the morphological changes in the STN. The red nucleus (RN) has many connections with the motor coordinating pathways although it is not primarily involved in the pathogenesis. In this study we aimed to compare the volumes of the STN and RN measured by magnetic resonance imaging in PD patients and controls to investigate how these structures are affected at the morphological level. Twenty patients with PD and twenty age/sex matched controls were enrolled in this study. Severity score was determined by Hoehn & Yahr staging: 6 at stage II and 14 at stage III in med-off state. Imaging was performed by a 1.5 Tesla (T) MR scanner. Measurements of total brain and normalized STN and RN volumes were performed by manual planimetry using Image J software. No statistically significant differences were observed between two groups based on age or gender and disease stage and nuclei volumes. The total estimated brain volumes were not different between PD patients and controls. However, normalized volumes of the STN and RN were 14% and 16% larger, respectively, in PD patients compared to the controls (p < 0.05). Our findings suggest that the volumes of the STN and RN are increased in patients with PD. These changes possibly reflect the altered metabolic activity of these regions demonstrated by neurophysiological studies.
Collapse
Affiliation(s)
- Ilkay Camlidag
- 1Department of Radiology, Ondokuz Mayis University , Samsun , Turkey
| | | | | | | | | | | | | | | | | |
Collapse
|
31
|
Abstract
Technological innovations have driven the advancement of the surgical treatment of movement disorders, from the invention of the stereotactic frame to the adaptation of deep brain stimulation (DBS). Along these lines, this review will describe recent advances in inserting neuromodulation modalities, including DBS, to the target, and in the delivery of therapy at the target. Recent radiological advances are altering the way that DBS leads are targeted and inserted, by refining the ability to visualize the subcortical targets using high-field strength magnetic resonance imaging and other innovations, such as diffusion tensor imaging, and the development of novel targeting devices enabling purely anatomical implantations without the need for neurophysiological monitoring. New portable computed tomography scanners also are facilitating lead implantation without monitoring, as well as improving radiological verification of DBS lead location. Advances in neurophysiological mapping include efforts to develop automatic target verification algorithms, and probabilistic maps to guide target selection. The delivery of therapy at the target is being improved by the development of the next generation of internal pulse generators (IPGs). These include constant current devices that mitigate the variability introduced by impedance changes of the stimulated tissue and, in the near future, devices that deliver novel stimulation patterns with improved efficiency. Closed-loop adaptive IPGs are being tested, which may tailor stimulation to ongoing changes in the nervous system, reflected in biomarkers continuously recorded by the devices. Finer-grained DBS leads, in conjunction with new IPGs and advanced programming tools, may offer improved outcomes via current steering algorithms. Finally, even thermocoagulation-essentially replaced by DBS-is being advanced by new minimally-invasive approaches that may improve this therapy for selected patients in whom it may be preferred. Functional neurosurgery has a history of being driven by technological innovation, a tradition that continues into its future.
Collapse
Affiliation(s)
- Robert E Gross
- Department of Neurosurgery, Emory University School of Medicine, 1365 Clifton Road, NE Suite 6200, Atlanta, GA 30322, USA.
| | | |
Collapse
|