1
|
Polly D, Mundis G, Eastlack R, Leveque JC, Elder BD, Martin C, Kent R, Snowden R, Kim HJ, Sembrano J, Herzog J, Lieberman I, Matheus V, Buchholz A, Franke J, Lee R, Shaffrey C. Randomized Trial of Augmented Pelvic Fixation in Patients Undergoing Thoracolumbar Fusion for Adult Spine Deformity: Initial Results from a Multicenter Randomized Trial. World Neurosurg 2024; 187:e15-e27. [PMID: 38310950 DOI: 10.1016/j.wneu.2024.01.156] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2023] [Revised: 01/26/2024] [Accepted: 01/27/2024] [Indexed: 02/06/2024]
Abstract
BACKGROUND The optimal configuration for spinopelvic fixation during multilevel spine fusion surgery for adult spine deformity remains unclear. Postoperative sacroiliac (SI) joint pain, S2AI screw loosening and implant breakage could be related to continued motion of the SI joint with use of only a single point of fixation across the SI joint. METHODS Prospective, international, multicenter randomized controlled trial of 222 patients with adult spine deformity scheduled for multilevel (4 or more levels) spine fusion surgery with pelvic fixation. Subjects were randomized to sacroalar (S2) iliac (S2AI) screws alone for pelvic fixation or S2AI + triangular titanium implants placed cephalad to S2AI screws. Quad rod techniques were not allowed or used. Baseline spinal deformity measures were read by an independent radiologist. Site-reported perioperative adverse events were reviewed by a clinical events committee. Quality of life questionnaires and other clinical outcomes are in process with planned 2-year follow-up. RESULTS One hundred thirteen participants were assigned to S2AI and 109 to S2AI + titanium triangular implants (TTI). 35/222 (16%) of all subjects had a history of SI joint pain or were diagnosed with SI joint pain during preoperative workup. Three-month follow-up was available in all but 4 subjects. TTI placement was successful in 106 of 109 (98%) subjects assigned to TTI. In 2 cases, TTI could not be placed due to anatomical considerations. Three TTI ventral iliac breaches were observed, all of which were managed non-surgically. One TTI subject had a transverse sacral fracture and 1 TTI subject had malposition of the implant requiring removal. CONCLUSIONS SI joint pain is common in patients with adult spinal deformity who are candidates for multilevel spine fusion surgery. Concurrent placement of TTI parallel to S2AI screws during multilevel spine fusion surgery is feasible and safe. Further follow-up will help to determine the clinical value of this approach to augment pelvic fixation.
Collapse
Affiliation(s)
- David Polly
- University of Minnesota, Minneapolis, Minnesota, USA.
| | - Greg Mundis
- San Diego Spine Foundation, San Diego, California, USA
| | | | | | | | | | - Roland Kent
- Axis Spine Center, Coeur D'Alene, Idaho, USA
| | - Ryan Snowden
- Tennessee Orthopaedics Associates, Nashville, Tennessee, USA
| | - Han Jo Kim
- Hospital for Special Surgery, New York, New York, USA
| | | | | | | | | | | | | | - Robert Lee
- Royal National Orthopaedic Hospital, Stanmore, UK
| | | |
Collapse
|
2
|
Rahmani R, Stegelmann SD, Andreshak T. S2 alar-iliac screws are superior to traditional iliac screws for spinopelvic fixation in adult spinal deformity: a systematic review and meta-analysis. Spine Deform 2024; 12:829-842. [PMID: 38427156 DOI: 10.1007/s43390-024-00834-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/29/2023] [Accepted: 01/20/2024] [Indexed: 03/02/2024]
Abstract
PURPOSE Spinopelvic fixation (SPF) using traditional iliac screws has provided biomechanical advantages compared to previous constructs, but common complications include screw prominence and wound complications. The newer S2 alar-iliac (S2AI) screw may provide a lower profile option with lower rates of complications and revisions for adult spinal deformity (ASD). The purpose of this study was to compare rates of complications and revision following SPF between S2AI and traditional iliac screws in patients with ASD. METHODS A PRISMA-compliant systematic literature review was conducted using Cochrane, Embase, and PubMed. Included studies reported primary data on adult patients undergoing S2AI screw fixation or traditional IS fixation for ASD. Primary outcomes of interest were rates of revision and complications, which included screw failure (fracture and loosening), symptomatic screw prominence, wound complications (dehiscence and infection), and L5-S1 pseudarthrosis. RESULTS Fifteen retrospective studies with a total of 1502 patients (iliac screws: 889 [59.2%]; S2AI screws: 613 [40.8%]) were included. Pooled analysis indicated that iliac screws had significantly higher odds of revision (17.1% vs 9.1%, OR = 2.45 [1.25-4.77]), symptomatic screw prominence (9.9% vs 2.2%, OR = 6.26 [2.75-14.27]), and wound complications (20.1% vs 4.4%, OR = 5.94 [1.55-22.79]). S2AI screws also led to a larger preoperative to postoperative decrease in pain (SMD = - 0.26, 95% CI = -0.50, - 0.011). CONCLUSION The findings from this review demonstrate higher rates of revision, symptomatic screw prominence, and wound complications with traditional iliac screws. Current data supports the use of S2AI screws specifically for ASD. PROSPERO ID CRD42022336515. LEVEL OF EVIDENCE III.
Collapse
Affiliation(s)
- Roman Rahmani
- Mercy Health St. Vincent Medical Center, Toledo, OH, USA
| | - Samuel D Stegelmann
- HCA Medical City Healthcare UNT-TCU GME (Denton), 3535 S Interstate 35, Denton, TX, 76210, USA.
| | | |
Collapse
|
3
|
Marie-Hardy L, Alvarez D, Pietton R, Mohsinaly Y, Bonaccorsi R, Pascal-Moussellard H. Kappa: Preliminary Results on a Novel Technique for Pelvic Fixation in Adult Spinal Deformity Correction. Indian J Orthop 2023; 57:1826-1832. [PMID: 37881294 PMCID: PMC10593650 DOI: 10.1007/s43465-023-00959-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/16/2022] [Accepted: 07/20/2023] [Indexed: 10/27/2023]
Abstract
Study Design Retrospective cohort study. Objectives Pelvic fixation in degenerative spinal deformation is as crucial as demanding. Several pelvic anchoring technics have been described, but loosening rates remain high for most solutions. Here is described the "Kappa" technic, combining ilio-sacral screws to S2A1 screws at 2 years of follow-up. Methods Thirteen patients that underwent a spinal deformity correction with "Kappa" fixation to the pelvis and with more than 2 years of follow-up were prospectively included in this study. The surgical technic is described, and clinical and radiographic data have been collected for all patients. Results The population exhibited an important pre-operative sagittal imbalance (mean SVA of 104,4 mm, mean PI-LL mismatch of 22,8°) that had improved significatively after surgery (mean SVA of 75,5 mm and mean PI-LL mismatch of 4,9°). No loosening of pull-out of the implants was to deplore at 2 years of follow-up. Conclusions The association of ilio-sacral screw, resistant to pull-out because of the traction axis perpendicular to the construct, to S2A1 screws, known to be effective in sagittal balance restoration seems to be an effective and safe option to pelvic fixation for adult spinal deformity correction. Level of Evidence IV.
Collapse
Affiliation(s)
- L. Marie-Hardy
- Department of Orthopaedic and Trauma Surgery, Pitié-Salpêtrière Hospital, Assistance Publique-Hôpitaux de Paris, Paris, France
| | - D. Alvarez
- Department of Orthopaedic and Trauma Surgery, Dr. Exequiel Gonzales Cortez Hospital, Santiago, Chile
| | - R. Pietton
- Department of Orthopaedic and Trauma Surgery, Pitié-Salpêtrière Hospital, Assistance Publique-Hôpitaux de Paris, Paris, France
| | - Y. Mohsinaly
- Department of Orthopaedic and Trauma Surgery, Pitié-Salpêtrière Hospital, Assistance Publique-Hôpitaux de Paris, Paris, France
| | - R. Bonaccorsi
- Department of Orthopaedic and Trauma Surgery, Pitié-Salpêtrière Hospital, Assistance Publique-Hôpitaux de Paris, Paris, France
| | - H. Pascal-Moussellard
- Department of Orthopaedic and Trauma Surgery, Pitié-Salpêtrière Hospital, Assistance Publique-Hôpitaux de Paris, Paris, France
| |
Collapse
|
4
|
Yang H, Pan A, Hai Y, Cheng F, Ding H, Liu Y. Biomechanical evaluation of multiple pelvic screws and multirod construct for the augmentation of lumbosacral junction in long spinal fusion surgery. Front Bioeng Biotechnol 2023; 11:1148342. [PMID: 36998811 PMCID: PMC10043192 DOI: 10.3389/fbioe.2023.1148342] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2023] [Accepted: 03/06/2023] [Indexed: 03/15/2023] Open
Abstract
Background: Posterior long spinal fusion was the common procedure for adult spinal deformity (ASD). Although the application of sacropelvic fixation (SPF), the incidence of pseudoarthrosis and implant failure is still high in long spinal fusion extending to lumbosacral junction (LSJ). To address these mechanical complications, advanced SPF technique by multiple pelvic screws or multirod construct has been recommended. This was the first study to compare the biomechanical performance of combining multiple pelvic screws and multirod construct to other advanced SPF constructs for the augmentation of LSJ in long spinal fusion surgery through finite element (FE) analysis.Methods: An intact lumbopelvic FE model based on computed tomography images of a healthy adult male volunteer was constructed and validated. The intact model was modified to develop five instrumented models, all of which had bilateral pedicle screw (PS) fixation from L1 to S1 with posterior lumbar interbody fusion and different SPF constructs, including No-SPF, bilateral single S2-alar-iliac (S2AI) screw and single rod (SS-SR), bilateral multiple S2AI screws and single rod (MS-SR), bilateral single S2AI screw and multiple rods (SS-MR), and bilateral multiple S2AI screws and multiple rods (MS-MR). The range of motion (ROM) and stress on instrumentation, cages, sacrum, and S1 superior endplate (SEP) in flexion (FL), extension (EX), lateral bending (LB), and axial rotation (AR) were compared among models.Results: Compared with intact model and No-SPF, the ROM of global lumbopelvis, LSJ, and sacroiliac joint (SIJ) was decreased in SS-SR, MS-SR, SS-MR, and MS-MR in all directions. Compared with SS-SR, the ROM of global lumbopelvis and LSJ of MS-SR, SS-MR, and MS-MR further decreased, while the ROM of SIJ was only decreased in MS-SR and MS-MR. The stress on instrumentation, cages, S1-SEP, and sacrum decreased in SS-SR, compared with no-SPF. Compared with SS-SR, the stress in EX and AR further decreased in SS-MR and MS-SR. The most significantly decreased ROM and stress were observed in MS-MR.Conclusion: Both multiple pelvic screws and multirod construct could increase the mechanical stability of LSJ and reduce stress on instrumentation, cages, S1-SEP, and sacrum. The MS-MR construct was the most adequate to reduce the risk of lumbosacral pseudarthrosis, implant failure, and sacrum fracture. This study may provide surgeons with important evidence for the application of MS-MR construct in the clinical settings.
Collapse
Affiliation(s)
| | | | - Yong Hai
- *Correspondence: Yong Hai, ; Yuzeng Liu,
| | | | | | - Yuzeng Liu
- *Correspondence: Yong Hai, ; Yuzeng Liu,
| |
Collapse
|
5
|
Beyond the pedicle screw-a patent review. EUROPEAN SPINE JOURNAL : OFFICIAL PUBLICATION OF THE EUROPEAN SPINE SOCIETY, THE EUROPEAN SPINAL DEFORMITY SOCIETY, AND THE EUROPEAN SECTION OF THE CERVICAL SPINE RESEARCH SOCIETY 2022; 31:1553-1565. [PMID: 35380271 DOI: 10.1007/s00586-022-07193-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/04/2022] [Revised: 03/17/2022] [Accepted: 03/18/2022] [Indexed: 10/18/2022]
Abstract
PURPOSE This review provides an overview of the patent literature on posteriorly placed intrapedicular bone anchors. Conventional pedicle screws are the gold standard to create a fixation in the vertebra for spinal fusion surgery but may lack fixation strength, especially in osteoporotic bone. The ageing population demands new bone anchors that have an increased fixation strength, that can be placed safely, and, if necessary, can be removed without damaging the surrounding tissue. METHODS The patent search was conducted using a classification search in the Espacenet patent database. Only patents with a Cooperative Patent Classification of A61B17/70 or A61B17/7001 concerning spinal positioners and stabilizers were eligible for inclusion. The search query resulted in the identification of 731 patents. Based on preset inclusion criteria, a total of 56 unique patents on different anchoring methods were included, reviewed and categorized in this study. RESULTS Five unique fixation methods were identified; (1) anchors that use threading, (2) anchors that utilize a curved path through the vertebra, (3) anchors that (partly) expand, (4) anchors that use cement and (5) anchors that are designed to initiate bone ingrowth. Of the anchor designs included in this study, eight had a corresponding commercial product, six of which were evaluated in clinical trials. CONCLUSION This review provides insights into worldwide patented intrapedicular bone anchors that aim to increase the fixation strength compared to the conventional pedicle screw. The identified anchoring methods and their working principles can be used for clinical decision-making and as a source of inspiration when designing novel bone anchors.
Collapse
|
6
|
de Andrada Pereira B, Wangsawatwong P, Lehrman JN, Sawa AGU, Lindsey DP, Yerby SA, Godzik J, Waguespack AM, Uribe JS, Kelly BP. Biomechanics of a laterally placed sacroiliac joint fusion device supplemental to S2 alar-iliac fixation in a long-segment adult spinal deformity construct: a cadaveric study of stability and strain distribution. J Neurosurg Spine 2021; 36:42-52. [PMID: 34534964 DOI: 10.3171/2021.3.spine202175] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2020] [Accepted: 03/01/2021] [Indexed: 11/06/2022]
Abstract
OBJECTIVE S2 alar-iliac (S2AI) screw fixation effectively enhances stability in long-segment constructs. Although S2AI fixation provides a single transarticular sacroiliac joint fixation (SIJF) point, additional fixation points may provide greater stability and attenuate screw and rod strain. The objectives of this study were to evaluate changes in stability and pedicle screw and rod strain with extended distal S2AI fixation and with supplemental bilateral integration of two sacroiliac joint fusion devices implanted using a traditional minimally invasive surgical approach. METHODS Eight L1-pelvis human cadaveric specimens underwent pure moment (7.5 Nm) and compression (400 N) tests under 4 conditions: 1) intact (pure moment loading only); 2) L2-S1 pedicle screw and rod with L5-S1 interbody fusion; 3) added S2AI screws; and 4) added bilateral laterally placed SIJF. Range of motion (ROM), rod strain, and screw-bending moment (S1 and S2AI) were analyzed. RESULTS Compared with S1 fixation, S2AI fixation significantly reduced L5-S1 ROM in right lateral bending by 50% (0.11°, p = 0.049) and in compression by 39% (0.22°, p = 0.003). Compared with fixation ending at S1, extending fixation with S2AI significantly decreased sacroiliac joint ROM by 52% (0.28°, p = 0.02) in flexion, by 65% (0.48°, p = 0.04) in extension, by 59% (0.76°, p = 0.02) in combined flexion-extension, and by 36% (0.09°, p = 0.02) in left axial rotation. The addition of S2AI screws reduced S1 screw-bending moment during flexion (0.106 Nm [43%], p = 0.046). With S2AI fixation, posterior L5-S1 primary rod strain increased by 124% (159 μE, p = 0.002) in flexion, by 149% (285 μE, p = 0.02) in left axial rotation, and by 99% (254 μE, p = 0.04) in right axial rotation. Compared with S2AI fixation, the addition of SIJF reduced L5-S1 strain during right axial rotation by 6% (28 μE, p = 0.04) and increased L5-S1 strain in extension by 6% (28 μE, p = 0.02). CONCLUSIONS Long-segment constructs ending with S2AI screws created a more stable construct than those ending with S1 screws, reducing lumbosacral and sacroiliac joint motion and S1 screw-bending moment in flexion. These benefits, however, were paired with increased rod strain at the lumbosacral junction. The addition of SIJF to constructs ending at S2AI did not significantly change SI joint ROM or S1 screw bending and reduced S2AI screw bending in compression. SIJF further decreased L5-S1 rod strain in axial rotation and increased it in extension.
Collapse
Affiliation(s)
- Bernardo de Andrada Pereira
- 1Spinal Biomechanics Laboratory, Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona
| | - Piyanat Wangsawatwong
- 1Spinal Biomechanics Laboratory, Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona
| | - Jennifer N Lehrman
- 1Spinal Biomechanics Laboratory, Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona
| | - Anna G U Sawa
- 1Spinal Biomechanics Laboratory, Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona
| | | | | | - Jakub Godzik
- 3Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona; and
| | | | - Juan S Uribe
- 3Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona; and
| | - Brian P Kelly
- 1Spinal Biomechanics Laboratory, Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona
| |
Collapse
|